130

1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Oct 16, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Product CatalogueBD Medical - Medical Surgical Systems and Diabetes Care

Eastern Europe, Middle East and Africa

valid from December 2007

Page 2: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

INJECTION SYSTEMS

SAFETY

DIABETES CARE

INFUSION THERAPY

ANAESTHESIA SYSTEMS

CRITICAL CARE AND HAEMODYNAMIC MONITORING

CO

NTE

NT

SURGICAL ACCESSORIES

ANNEX

Page 3: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

SA

FETY

Page 4: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

4 Safety - Injection Systems

BD Eclipse™ - see page 25 BD SafetyGlide™ - see page 26

BD Integra™ - see page 27

Injection Systems

BD™ Blunt Fill needle - see page 17

BD™ Saline - Prefilled syringes - see page 24 BD™ Sharps Disposal Systems - see page 28

Page 5: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Safety - Injection Systems 5

Injection Systems

BD SoloMed™ 2-piece syringes with breakable plunger - see page 30 BD SoloMed™ 3-piece with breakable plunger - see page 31

BD™ Hub Cutter - see page 34

BD SoloMed™ 3-piece syringes with breakable plunger and safetyneedle shield - see page 32

BD SoloShot™ IX - see page 33

BD SoloShot™ LX - see page 33

Page 6: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

6

Injection Systems

Description Needle Dimensions Box content Item numberunits

1 ml 27G 1/2" - 0.4 x 13 mm 50 3057893 ml 25G 5/8" - 0.5 x 16 mm 50 3057813 ml 23G 1" - 0.6 x 25 mm 50 3057823 ml 22G 11/2" - 0.7 x 40 mm 50 3057833 ml 21G 11/2" - 0.8 x 40 mm 50 3057845 ml 22G 11/2" - 0.7 x 40 mm 50 30578510 ml 22G 11/2" - 0.7 x 40 mm 50 305786

BD Eclipse™ needle with BD Luer-Lok™ syringes

Needle Dimensions Box content Item numberunits

30G 1/2" - 0.29 x 13 mm 50 30577127G 1/2" - 0.4 x 13 mm 50 30577025G 5/8" - 0.5 x 16 mm 50 30576023G 1" - 0.6 x 25 mm 50 30589221G 11/2" - 0.8 x 40 mm 50 30589521G 1" - 0.8 x 25 mm 50 30589420 G 1" - 0.9 x 25 mm 50 305899

BD Eclipse™ needles with BD SmartSlip™ technology

Description Needle Dimensions Box content Item numberunits

3 ml 25G 5/8" - 0.5 x 16 mm 50 3059043 ml 23G 1" - 0.6 x 25 mm 50 3059055 ml 22G 11/2" - 0.7 x 25 mm 50 30590710 ml 22G 11/2" - 0.7 x 25 mm 50 305908

BD SafetyGlide™ needle with BD Luer-Lok™ syringe

Description Needle Dimensions Box content Item numberunits

1 ml 27G 1/2" - 0.4 x 13 mm 100 3059451 ml 26G 3/8" - 0.45 x 10 mm 100 305946

BD SafetyGlide™ syringes with integrated needle

Description Box content Item numberunits

3 ml syringe only 100 305283

BD Integra™ syringe with retracting BD PrecisionGlide™ needle

Needle Dimensions Box content Item numberunits

25G x 5/8" - 0.5 x 16 mm 100 30531025G x 1" - 0.5 x 25 mm 100 30531123G x 1" - 0.6 x 25 mm 100 30531222G x 11/2" - 0.7 x 40 mm 100 305313

Description Box content Item numberunits

3 ml syringe with detachable 25G x 5/8" needle 100 3052693 ml syringe with detachable 25G x 1" needle 100 3052703 ml syringe with detachable 23G x 1" needle 100 3052713 ml syringe with detachable 22G x 11/2" needle 100 3052723 ml syringe with detachable 21G x 1" needle 100 3052733 ml syringe with detachable 21G x 11/2" needle 100 305274

BD Integra™ syringe

BD Integra™ retracting needles

Description Needle Dimensions Box content Item numberunits

1 ml TB 27G x 1/2" - 0.4 x 13 mm 100 3052981 ml TB 26G x 3/8" - 0.45 x 10 mm 100 3052791 ml 25G x 1" - 0.5 x 25 mm 100 3052781 ml 25G x 5/8" - 0.5 x 16 mm 100 3052771 ml insulin syringe U-100 29G x 1/2" - 0.33 x 13 mm 100 305282

BD Integra™ syringe with permanently attached BD PrecisionGlide™ needle

Needle Dimensions Box content Item numberunits

18G x 11/2" - 1.25 x 40 mm 100 30527518G x 11/2" - 1.25 x 40 mm with 5 micron filter 100 305833

BD Integra™ blunt, non-retracting needles

Safety - Injection Systems

Page 7: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Safety - Injection Systems 7

Injection Systems

Description Box content Item numberunits

3 ml BD™ Saline SP 30 3065545 ml BD™ Saline SP 30 30655510 ml BD™ Saline SP 30 306556

BD™ Saline SP - Sterile Fluid Path - prefilled flushing devices

Description Box content Item numberunits

3 ml BD™ Saline XS 30 3065705 ml BD™ Saline XS 30 30657110 ml BD™ Saline XS 30 306572

BD™ Saline XS - EXternally Sterile - prefilled flushing devices

Next Generation BD™ Sharps Disposal Systems

Description Gauge Colour code Box content Item numberand Length units

BD™ Blunt Fill Needle 18G x 11/2" Red 100 305180BD™ Blunt Fill Needle with 5 micron Filter 18G x 11/2" Red 100 305211

BD™ Blunt Fill needle

Product Nominal Capacity Usable Capacity Box content Item number(Litre) (Litre) units

0.45 L Sharps Container 0.45 L 0.36 L 100 3024340.87 L Sharps Container 0.87 L 0.7 L 50 3672021.5 L Sharps Container 1.5 L 1.2 L 40 3056243.0 L Sharps Container 3.0 L 2.4 L 25 3056255.0 L Sharps Container 5.0 L 4.0 L 20 3056267.0 L Sharps Container 7.0 L 5.6 L 16 30562722.7 L Sharps Container 22.7 L 18.2 L 12 300479

Brackets Supports & Description Box content Item numberAccessories units0.87 L Metal Cup Bracket Metal cup bracket for placement on horizontal surfaces. 50 3059700.45 L Desktop Bracket Plastic bracket for placement on horizontal surfaces. 12 3059641.5 L Desktop Bracket Multipurpose metal bracket suitable for placement on 6 3056453.0 L Desktop Bracket horizontal surfaces, secure wall mounting and fastened 6 3052505.0 L Desktop Bracket to a rail with the use of an adaptor. 6 3052537.0 L Desktop Bracket 6 3052551.5 L Hanging Bracket Metal bracket suitable for attaching to medication carts. 6 3057103.0 L Hanging Bracket 6 3052515.0 L Hanging Bracket 6 3052527.0 L Hanging Bracket 6 305254Universal Adopter (small) Suitable for attaching all desktop brackets to rails or countertops for 6 305636Universal Adopter (large) space saving efficiency. 6 305637Replacement Suction Cups For secure fitment of all horizontally mounted desktop brackets. 8 305968

Page 8: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

8 Safety - Injection Systems

Injection Systems

Description Tip Scale Box content Item numberunits

2 ml Luer Slip Concentric 0.1 ml 100 3026545 ml Luer Slip Eccentric 0.2 ml 100 30265510 ml Luer Slip Eccentric 0.5 ml 100 302758

BD SoloMed™ 2-piece syringes with breakable plunger

Description BD Microlance™ Box content Item numberNeedle Dimensions units

2 ml Luer Slip 25G 5/8" - 0.5 x 16 mm 100 3026502 ml Luer Slip 24G 1" - 0.55 x 25 mm 100 3026922 ml Luer Slip 23G 1" - 0.6 x 25 mm 100 3026402 ml Luer Slip 23G 11/4" - 0.6 x 30 mm 100 3026905 ml Luer Slip 23G 1" - 0.6 x 25 mm 100 3026425 ml Luer Slip 23G 11/4" - 0.6 x 30 mm 100 3026965 ml Luer Slip 22G 11/4" - 0.7 x 30 mm 100 3026955 ml Luer Slip 21G 11/2" - 0.8 x 40 mm 100 30265810 ml Luer Slip 21G 11/2" - 0.8 x 40 mm 100 302761

BD SoloMed™ 2-piece syringes with breakable plunger and needles packed aside

Description Tip Scale Box content Item numberunits

3 ml Luer Slip Concentric 0.1 ml 100 3026725 ml Luer Slip Eccentric 0.2 ml 100 30267810 ml Luer Slip Eccentric 0.5 ml 100 302683

BD SoloMed™ 3-piece syringes with breakable plunger

Description BD Microlance™ Box content Item numberNeedle Dimensions units

3 ml Luer Slip 25G 5/8" - 0.5 x 16 mm 100 3027073 ml Luer Slip 23G 11/4" - 0.6 x 30 mm 100 3027083 ml Luer Slip 22G 11/2" - 0.7 x 40 mm 100 3026075 ml Luer Slip 23G 11/4" - 0.6 x 30 mm 100 3027115 ml Luer Slip 21G 11/2" - 0.8 x 40 mm 100 30270910 ml Luer Slip 21G 11/2" - 0.8 x 40 mm 100 302721

BD SoloMed™ 3-piece syringes with breakable plunger and needle packed aside

Description Tip Scale Box content Item numberunits

3 ml BD Luer-Lok™ Concentric 0.1 ml 100 3026565 ml BD Luer-Lok™ Concentric 0.2 ml 100 30265710 ml BD Luer-Lok™ Concentric 0.5 ml 100 302684

BD SoloMed™ 3-piece syringes with breakable plunger

Description BD Microlance™ Box content Item numberNeedle Dimensions units

3 ml BD Luer-Lok™ 25G 5/8" - 0.5 x 16 mm 100 3026443 ml BD Luer-Lok™ 23G 1" - 0.6 x 25 mm 100 3026413 ml BD Luer-Lok™ 23G 11/4" - 0.6 x 30 mm 100 3027043 ml BD Luer-Lok™ 22G 11/2" - 0.7 x 40 mm 100 3027185 ml BD Luer-Lok™ 23G 1" - 0.6 x 25 mm 100 3026435 ml BD Luer-Lok™ 23G 11/4" - 0.6 x 30 mm 100 3027425 ml BD Luer-Lok™ 21G 11/2" - 0.8 x 40 mm 100 30264510 ml BD Luer-Lok™ 21G 11/2" - 0.8 x 40 mm 100 302729

BD SoloMed™ 3-piece syringes with breakable plunger and needle packed aside

Page 9: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Safety - Injection Systems 9

BD™ Hub CutterDescription Fill capacity Box content Item number

unitsBD™ Hub Cutter for hypodermic needles in average 400-600 needles 32 305307BD™ Hub Cutter for hypodermic needles (Russian Label) in average 400-600 needles 32 305309

Description Needle Dimensions ISO Colour Code Box content Item numberunits

0.5 ml 23G 1" - 0.6 x 25 mm Blue 200 3018600.5 ml 24G 3/4" - 0.55 x 19 mm Violet 200 3018890.5 ml 25G 1" - 0.5 x 25 mm Orange 200 3018650.5 ml 25G 5/8" - 0.5 x 16 mm Orange 200 3018871.0 ml 22G 1" - 0.7 x 25 mm Black 200 301888*

BD SoloShot™ IX - Auto-disable syringe with integrated needle

Description Needle Dimensions Box content Item numberunits

0.05 ml 27G 3/8" - 0.4 x 10 mm 100 3017920.1 ml 27G 3/8" - 0.4 x 10 mm 100 3017930.05 ml - 0.10 ml combo 27G 3/8" - 0.4 x 10 mm 100 303212

BD SoloShot™ LX - BCG Auto-disable syringe with integrated needle

Injection Systems

Description Tip Scale Box content Item numberunits

3 ml Luer Slip Concentric 0.1 ml 100 3026745 ml Luer Slip Eccentric 0.2 ml 100 30268010 ml Luer Slip Eccentric 0.5 ml 100 302686

BD SoloMed™ 3-piece syringes with breakable plunger and safety needle shield*

Description BD Microlance™ Box content Item numberNeedle Dimensions units

3 ml Luer Slip 22G 11/2" - 0.7 x 40 mm 100 3027123 ml Luer Slip 23G 11/4" - 0.6 x 30 mm 100 3027135 ml Luer Slip 21G 1" - 0.8 x 25 mm 100 3026825 ml Luer Slip 21G 11/2" - 0.8 x 40 mm 100 30271510 ml Luer Slip 21G 11/2" - 0.8 x 40 mm 100 302688

BD SoloMed™ 3-piece syringes with breakable plunger and safety needle shield with mounted needles*

Description Tip Scale Box content Item numberunits

3 ml BD Luer-Lok™ Concentric 0.1 ml 100 3026735 ml BD Luer-Lok™ Concentric 0.2 ml 100 30267910 ml BD Luer-Lok™ Concentric 0.5 ml 100 302685

BD SoloMed™ 3-piece syringes with breakable plunger and safety needle shield*

Description BD Microlance™ Box content Item numberNeedle Dimensions units

3 ml BD Luer-Lok™ 25G 5/8" - 0.5 x 16 mm 100 3024783 ml BD Luer-Lok™ 23G 1" - 0.6 x 25 mm 100 3027755 ml BD Luer-Lok™ 23G 11/4" - 0.6 x 30 mm 100 3027735 ml BD Luer-Lok™ 23G 11/2" - 0.6 x 40 mm 100 3024695 ml BD Luer-Lok™ 22G 11/2" - 0.7 x 40 mm 100 3024685 ml BD Luer-Lok™ 21G 11/2" - 0.8 x 40 mm 100 30246710 ml BD Luer-Lok™ 21G 11/2" - 0.8 x 40 mm 100 302639

BD SoloMed™ 3-piece syringes with breakable plunger and safety needle shield with mounted needles*

* Please contact your local sales representative for product availability.

Page 10: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

10Safety - Infusion Therapy

Infusion Therapy

BD Venflon™ Pro Safety - see page 42

BD Insyte-N™ Autoguard™ - see page 48

BD Insyte™ Autoguard™ and BD Insyte™ Autoguard™ Winged -see page 45

BD Saf-T-Intima™ and BD Saf-T-Intima™ Y - see page 50

BD Nexiva™ Standard Version - see page 51 BD Nexiva™ with BD Connecta™ Q-Syte™ Stopcock Version - see page52

Page 11: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Safety - Infusion Therapy 11

Infusion Therapy

BD Posiflow™ - see page 55BD Connecta™ Stopcock with BD Q-Syte™ - see page 54

BD Q-Syte™ - see page 53 BD Q-Syte™ Extension Sets - see page 54

Page 12: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Infusion Therapy

Safety - Infusion Therapy

BD Insyte™ Autoguard™ and BD Insyte™ Autoguard-W™

BD Saf-T-Intima™ and BD Saf-T-Intima™ YGauge Length Catheter ext. Colour Box content BD Saf-T-Intima™ BD Saf-T-Intima™ YCatheter mm diameter mm units Item number Item number24G 19 0.7 Yellow 25 383312 38331322G 19 0.8 Blue 25 383322 38332320G 25 1.1 Pink 25 383335 38333618G 25 1.3 Green 25 - 383346

BD Insyte-N™ Autoguard™Gauge Length Catheter ext. Colour Box content Item numberCatheter mm diameter mm units24G 14 0.7 Yellow 50 38141124G with wings 14 0.7 Yellow 50 381511

12

Gauge Length Catheter Catheter Colour Box content Item numberCatheter mm O.D. mm I.D. mm units22G 25 0.9 0.6 Blue 50 39322220G 32 1.1 0.8 Pink 50 39322418G 32 1.3 1.0 Green 50 39322618G 45 1.3 1.0 Green 50 39322717G 45 1.5 1.2 White 50 39322816G 45 1.8 1.4 Grey 50 39322914G 45 2.0 1.6 Orange 50 393230

BD Venflon™ Pro Safety

BD Nexiva™ Standard Version

GaugeCatheter

Lengthmm Colour

Flow RateH20 (ml/min)current

Flow RateH20 (ml/min)

new

Flow RateH20 (ml/h)new

Flush Volumecurrent

Flush Volumenew

Units(Box/Case)

CurrentItemNumber

FutureItem

Number

24 14 Yellow 17 14 840 0,3 0,4 20/80 383600 383640

24 19 Yellow 17 13 780 0,3 0,4 20/80 383601 383641

22 25 Blue 28 27 1620 0,3 0,4 20/80 383602 383642

20 25 Pink 45 54 3240 0.3 0.5 20/80 383605 383646

20 32 Pink 45 52 3120 0.3 0.5 20/80 383606 383647

20 45 Pink 40 48 2880 0.4 0.5 20/80 383607 383648

18 32 Green 65 84 5040 0.4 0.5 20/80 383608 383649

18 45 Green 60 78 4680 0.4 0.5 20/80 383609 383650

GaugeCatheter

Lengthmm

Cathether ext.diameter mm Colour Box content

units

BD Insyte™ Autoguard™without wingsItem Number

BD Insyte™ Autoguard™without wings

Future Item Number

BD Insyte™Autoguard™ Winged

Item Number

BD Insyte™Autoguard™ WingedFuture Item Number

24G 19 0.7 Yellow 50 381412 381812* 381512 381912*

22G 25 0.9 Blue 50 381423 381823* 381523 381923*

20G 51 1.1 Pink 50 381437 381437** 381537 381537**

20G 32 1.1 Pink 50 381434 381834* 381534 381934*

18G 51 1.3 Green 50 381447 381447** 381547 381547**

18G 32 1.3 Green 50 381444 381844* 381544 381944*

16G 51 1.7 Grey 50 381457 381457** 381557 381557**

14G 51 2.1 Orange 50 381467 381467** - -

*= available October 2008**= no change of code

Page 13: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Safety - Infusion Therapy 13

BD Posiflow™Description Box content Item

units numberIV Access Valve 50 385300BD Luer-Lok™ Extension Set 50 385301BD Luer-Lok™ Bifurcated Extension Set 50 385303“Y” Extension Set 25 385305Dual “Y” Extension Set 25 385306Microbore “Y” Extension Set 25 385324Vial Adapter 50 385308

Description Priming Volume Flow Rate Box content Item(ml) (ml/min.) units number

BD Q-Syte™ Stand Alone 0.1 525 50 385100BD Q-Syte™ 15 cm Standard Bore Extension 1.14 445 25 385101BD Q-Syte™ 15 cm Micro Bore Extension 0.21 49 50 385102

Description Priming Volume Flow Rate Box content Item(ml) (ml/min.) units number

BD Q-Syte™ Bi-Extension Set 15 cm Macro Bore 1.6 445 50 385161BD Q-Syte™ Tri-Extension Set 15 cm Macro Bore 2.25 445 50 385162BD Q-Syte™ Bi-Extension Set 15 cm Small Bore 0.45 49 50 385163BD Q-Syte™ Tri-Extension Set 15 cm Small Bore 0.8 49 50 385164BD Connecta™ Stopcock with BD Q-Syte™ 0.31 490/390 50 394501BD Q-Syte™ Vial Adapter 0.1 525 25 385108

BD Q-Syte™

BD Q-Syte™ Extension Sets

Infusion Therapy

BD Nexiva™ with BD Connecta™ Q-Syte™ Stopcock Version

GaugeCatheter

Lengthmm Colour

Flow RateH20 (ml/min)current

Flow RateH20 (ml/min)

new

Flow RateH20 (ml/h)new

Flush Volumecurrent

Flush Volumenew

Units(Box/Case)

CurrentItemNumber

FutureItem

Number

24 14 Yellow 17 16 960 0,5 0,6 20/80 383620 383660

24 19 Yellow 17 15 900 0,5 0,6 20/80 383621 383661

22 25 Blue 28 30 1800 0,6 0,6 20/80 383622 383662

20 25 Pink 45 52 3120 0.6 0.8 20/80 383625 383666

20 32 Pink 45 50 3000 0.6 0.8 20/80 383626 383667

20 45 Pink 40 46 2760 0.6 0.8 20/80 383627 383668

18 32 Green 65 78 4680 0.6 0.8 20/80 383628 383669

18 45 Green 60 74 4440 0.6 0.8 20/80 383629 383670

BD Nexiva™ with Single BD Connecta™ Stopcock Version

GaugeCatheter

Lengthmm Colour

Flow RateH20 (ml/min)current

Flow RateH20 (ml/min)

new

Flow RateH20 (ml/h)new

Flush Volumecurrent

Flush Volumenew

Units(Box/Case)

CurrentItemNumber

FutureItem

Number

24 14 Yellow 17 16 960 0,5 0,6 20/80 383630 383680

24 19 Yellow 17 15 900 0,5 0,6 20/80 383631 383681

22 25 Blue 28 30 1800 0,6 0,6 20/80 383632 383682

20 25 Pink 45 52 3120 0.6 0.8 20/80 383635 383686

20 32 Pink 45 50 3000 0.6 0.8 20/80 383636 383687

20 45 Pink 40 46 2760 0.6 0.8 20/80 383637 383688

18 32 Green 65 78 4680 0.6 0.8 20/80 383638 383689

18 45 Green 60 74 4440 0.6 0.8 20/80 383639 383690

Page 14: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

INJE

CTI

ON

SY

STE

MS

Page 15: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

HYPODERMICNEEDLESBD Microlance™

Sterile, single use

Injection Systems

Gauge Needle Length Needle ext. Wall Bevel Colour code Box content Case content Item numberdiameter units units

16G 40 mm (11/2") 1.6 mm Regular Regular White 100 5000 30063718G 40 mm (11/2") 1.25 mm Thin Short Pink 100 5000 30462218G 50 mm (2") 1.25 mm Regular Short Pink 100 4000 30190019G 25 mm (1") 1.1 mm Thin Regular Cream 100 5000 30170019G 40 mm (11/2") 1.1 mm Thin Regular Cream 100 5000 30150019G 50 mm (2") 1.1 mm Thin Regular Cream 100 4000 30175020G 25 mm (1") 0.9 mm Thin Regular Yellow 100 5000 30482720G 40 mm (11/2") 0.9 mm Thin Regular Yellow 100 5000 30130021G 16 mm (5/8") 0.8 mm Thin Regular Green 100 5000 30443421G 25 mm (1") 0.8 mm Thin Regular Green 100 5000 30115621G 40 mm (11/2") 0.8 mm Thin Regular Green 100 5000 30443221G 50 mm (2") 0.8 mm Regular Regular Green 100 4000 30115522G 25 mm (1") 0.7 mm Thin Regular Black 100 5000 30472722G 30 mm (11/4") 0.7 mm Thin Regular Black 100 5000 30090022G 40 mm (11/2") 0.7 mm Thin Regular Black 100 5000 30100022G 50 mm (2") 0.7 mm Regular Regular Black 100 4000 30009423G 25 mm (1") 0.6 mm Thin Regular Blue 100 5000 30080023G 30 mm (11/4") 0.6 mm Thin Regular Blue 100 5000 30070024G 25 mm (1") 0.55 mm Regular Regular Violet 100 5000 30410025G 16 mm (5/8") 0.5 mm Regular Regular Orange 100 5000 30060025G 25 mm (1") 0.5 mm Regular Regular Orange 100 5000 30040026G 13 mm (1/2") 0.45 mm Regular Regular Brown 100 5000 30380026G 10 mm (3/8") 0.45 mm Regular Intradermal Brown 100 5000 30030026G 16 mm (5/8") 0.45 mm Regular Regular Brown 100 5000 30430027G 13 mm (1/2") 0.4 mm Regular Regular Grey 100 5000 30063527G 19 mm (3/4") 0.4 mm Regular Regular Grey 100 5000 30220030G 13 mm (1/2") 0.29 mm Regular Regular Yellow 100 5000 304000

BevelThe bevel design is based on the latest technology.In-vitro and in-vivo studies have shown the superior quality ofits penetration index.

Thin wallsPermitting the use of thinner needles with larger lumen thusincreasing flow rates during injection and collection.

BD Microlance™ can be connected to a Luer adapter orLuer Lock connector. Adapter and colour coding incompliance with ISO standards.

Type of materials� Hub and needle shield: Polypropylene� Pointed cannula: Stainless steel (AISI 304)

� Adhesive: Epoxy resin� Lubricant: Silicone oil� Packaging materials: Uncoated paper (medical

grade 60gr/cm2) and transparent blister film (PE/PA)

Recommended uses� Intradermal, Subcutaneous, Intramuscular, Intravenous

Sterilisation method� Ethylene oxide

� CE Marked

16

Page 16: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

17Injection Systems

FILL NEEDLES

BD Nokor™ Admix Needles

Description Gauge and Length Colour code Box content Item numberunits

BD Nokor™ Admix microthin wall 18G x 11/2" Pink 100 300779BD Nokor™ Admix microthin wall 16G x 1" Purple 100 300780

Description

� BD Nokor™ Needles scalpel-like tip glides through vialstopper quickly and easily. It also allows use of a largegauge needle for fast medication preparation without therisk of coring.

� Avoids foaming by directing fluid towards the side of thevial.

Sterilisation method

� Gamma Irradiation

� CE marked

BD™ Universal Fill NeedlesDescription Gauge and Length Colour code Box content Item number

unitsBD™ Blunt Fill Needle 18G x 11/2" Red 100 305180BD™ Blunt Fill Needle with 5 micron filter 18G x 11/2" Red 100 305211

Description

� Fill Needle with blunt tip

� Unique 45° bevel avoids coring and prevents from needlestick.

� Red hub and shield for easy identification as fill needle.

� Also available with 5 micron filter for effective filtration ofglass, metal, rubber and other contaminant particles.

Sterilisation method

� Ethylene oxide

� CE marked

Page 17: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

18 Injection Systems

2-PIECESYRINGESBD Discardit™

Sterile, single use

Description BD Microlance™ Needle Box content Case content Item numberGauge & Length units units

2 ml Luer Slip 21G 11/2" (0.8 x 40mm) 100 3000 3003182 ml Luer Slip 22G 11/4" (0.7 x 30mm) 100 3000 3003202 ml Luer Slip 22G 11/2" (0.7 x 40mm) 100 3000 3003212 ml Luer Slip 23G 1" (0.6 x 25mm) 100 3000 3003222 ml Luer Slip 23G 11/4" (0.6 x 30mm) 100 3000 3003235 ml Luer Slip 22G 11/2" (0.7 x 40mm) 100 1800 3005065 ml Luer Slip 21G 11/2" (0.8 x 40mm) 100 1800 3005125 ml Luer Slip 22G 11/4" (0.7 x 30mm) 100 1800 3005135 ml Luer Slip 23G 11/4" (0.6 x 30mm) 100 1800 30051610 ml Luer Slip 22G 11/4" (0.7 x 30mm) 100 1200 30062610 ml Luer Slip 21G 11/2" (0.8 x 40mm) 100 1200 30100110 ml Luer Slip 22G 11/2" (0.7 x 40mm) 100 1200 30150420 ml Luer Slip 21G 11/2" (0.8 x 40mm) 80 960 300330

Description

� Clear barrel for perfect visualisation of syringe contents

� Smooth plunger movement - reduced sliding force

� Leak-tight: BD Discardit™ syringes are tested duringmanufacture in compliance with ISO 7886-1

� Accuracy and safety: transparent barrel

� Scale marking: accurate graduation suited to user’s needs

� Retaining ring: prevent accidental plunger rod withdrawal

� Design of finger grip flanges fensures stability and comfortduring injection

� Ergonomically designed plunger for single-handedoperation.

Type of materials

� Barrel: Polypropylene

� Plunger: Polyethylene

� Individually (blister) packed: Paper (medical grade60gr/cm2), plastic film (polyethylene/polyamide)

Sterilisation method� Ethylene oxide

� CE Marked

BD Discardit™ 2-piece syringes with BD Microlance™ needle packed aside

BD Discardit™ 2-piece syringes

Description Tip Scale Box content Case content Item numberunits units

2 ml Luer Slip Concentric 0.1 ml 100 3000 3009285 ml Luer Slip Eccentric 0.2 ml 100 1800 30905010 ml Luer Slip Eccentric 0.5 ml 100 1200 30911020 ml Luer Slip Eccentric 1 ml 80 960 300296

Page 18: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Injection Systems

3-PIECESYRINGESBD Plastipak™- 2, 3, 5, 10 ml

Sterile, single use

Description Tip Scale Box content Case content Item numberunits units

2 ml Luer Slip Concentric 0.1 ml 100 800 3001855 ml Luer Slip Concentric 0.2 ml 100 400 30218710 ml Luer Slip Eccentric 0.5 ml 100 400 302188

BD Plastipak™ Luer Slip syringes without needle

BD Plastipak™ syringes with mounted needleDescription BD Microlance™ Box content Case content Item number

Needle Dimension units units2 ml* Luer Slip 25G x 5/8" - 0.5 x 16mm 100 800 3001902 ml* Luer Slip 23G x 1" - 0.6 x 25 mm 100 800 3001892 ml* Luer Slip 22G x 11/4" - 0.7 x 30 mm 100 800 3001882 ml* Luer Slip 21G x 11/2" - 0.8 x 40 mm 100 800 3001875 ml Luer Slip 22G x 11/4" - 0.7 x 30 mm 100 400 3080625 ml Luer Slip 21G x 11/2" - 0.8 x 40 mm 100 400 30806310 ml Luer Slip 21G x 11/2" - 0.8 x 40 mm 100 400 308027

Description Tip Scale Box content Case content Item numberunits units

3 ml BD Luer-Lok™ Concentric 0.1 ml 100 800 3009105 ml BD Luer-Lok™ Concentric 0.2 ml 100 400 30091110 ml BD Luer-Lok™ Concentric 0.2 ml 100 400 300912

BD Luer-Lok™ syringes without needle

General Description

� Latex free stopper: eliminates completely the risk ofallergic reactions to latex.

� Clear barrel for perfect visualisation of syringe contents.

� Bold scale printing for a more accurate dosage ofmedication.

� Special silicone lubrication ensures that plunger movessmoothly and evenly.

� Retaining ring: prevents accidental plunger rod withdrawal

Syringes with mounted needleCompact “syringe plus needle” unit provides all the benefitsof a BD Plastipak™ syringe and a BD Microlance™ needle atthe same time:

� Pre-assembled syringe plus needle in a single packsimplifies injections by reducing the number of proceduresand thereby reduces costs.

Type of materials

� Barrel and plunger: Polypropylene

� Plunger stopper: Synthetic rubber (Latex free)

� Lubricant: Silicone oil

� Needles: see BD Microlance™

� Packaging materials: Blister film, medical grade paper andcorrugated cardboard

Sterilisation method

� Ethylene oxide except BD Luer-Lok™ syringes

� BD Luer-Lok™ syringes sterilised by Gamma irradiation

� CE Marked

19

*The 2 ml syringes are graded to 2.5 ml

Page 19: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

20 Injection Systems

INJECTIONACCESSORIESBDTM Tip Cap Tray

Sterile, single use

Description Box content Case content Item numberunits units

Luer Tip Cap (Tray of 10)* 500 2000 308341

BD™ Tip Cap Tray

General Description

� Latex-free caps for ease of application.� Designed to minimize touch-contamination risk.

� Tray packaging reduces waste compared to single-sterilecaps.

� For Luer Lock and Luer Slip connections.

Sterilisation method

� Ethylene oxide

� CE Marked

*For additional caps and plugs please see page 60

Page 20: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

21Injection Systems

PRECISIONSYRINGESBD Plastipak™- 1 ml

Sterile, single use

Description Tip Scale Box content Case content Item numberunits units

1 ml Tuberculin /Allergy Concentric 0.01 ml 100 800 3000131 ml BD Luer-Lok™ Concentric 0.01 ml 100 800 3096281 ml Insulin Syringe U-40 Concentric U-40 100 800 3000261 ml Insulin Syringe U-100 Concentric U-100 100 800 301355

Description Scale BD Microlance™ Bevel Box content Case content Item numberNeedle Dimensions units units

1 ml test 0.01ml 27G x 3/8" - 0.4 x 10 mm Intradermal 100 500 3055021 ml Sub-Q 0.01ml 26G x 1/2" - 0.45 x 13 mm Regular 100 500 305501

BD™ Syringes without needle

BD™ Syringes with inserted needle

Description Scale BD Microlance™ Bevel Box content Case content Item numberNeedle Dimensions units units

1 ml 0.01ml 26G x 3/8" - 0.45 x 10 mm Intradermal 100 800 3000151 ml 0.01ml 25G x 5/8" - 0.5 x 16 mm Regular 100 800 3000141 ml Insulin Syringe U-40 U-40 30G x 1/2" - 0.29 x 13 mm Regular 100 800 300334

BD™ Syringes with mounted needle

Syringes with inserted needle

A new concept based on BD research. “Syringes withoutdead space” which:

� Minimize the formation of air bubbles

� Prevent any risk of detachment of needle

� Ensure administration of full dose

Syringes with mounted needleCompact “syringe plus needle” unit provides all the benefitsof a BD Plastipak™ syringe and a BD Microlance™ needle atthe same time:

� Pre-assembled syringe plus needle in a single packsimplifies injections by reducing the number of proceduresand thereby reduces costs.

Type of materials

� Barrel and plunger: Polypropylene

� 1 ml BD Luer-Lok™ made of polycarbonate

� Plunger stopper: Synthetic rubber (latex free)

� Lubricant: Silicone oil

� Needles: see BD Microlance™

Sterilisation method

� Ethylene oxide except BD Luer-Lok™

� BD Luer-Lok™ syringes sterilised by Gamma irradiation

� CE Marked

Page 21: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Injection Systems22

HIGH CAPACITYSYRINGESBD Plastipak™- 20, 30, 50, 100 ml

Sterile, single use

Description Tip Scale - Graduation Box content Case content Item numberunits units

20 ml Luer Slip Eccentric 1 ml 120 480 30061320 ml BD Luer-Lok™ Concentric 1 ml 120 480 30062930 ml Luer Slip Eccentric 1 ml 60 240 30123130 ml BD Luer-Lok™ Concentric 1 ml 60 240 301229100 ml Catheter Tip with Luer Adapter 1 ml 25 50 300605

BD Plastipak™ 20, 30 and 100 ml syringes

BD Plastipak™ 20 ml syringes with needle packed aside

BD Plastipak™ & BD™ Perfusion 50 ml syringes

BD™ Perfusion 50 ml syringes with mounted needle

Description BD Microlance™ Scale - Graduation Box content Case content Item numberNeedle Dimensions units units

20 ml 21G x 11/2" - 0.8 x 40 mm 1 ml 60 240 301190

Description Tip Scale - Graduation Box content Case content Item numberunits units

50 ml Luer Slip Eccentric 1 ml 60 240 30086650 ml BD Luer-Lok™ Concentric 1 ml 60 240 30086550 ml Catheter Tip 1 ml 60 240 30086750 ml Perfusion, BD Luer-Lok™ Concentric 1 ml 50 100 30013750 ml Amber, BD Luer-Lok™ Concentric 1 ml 60 240 30086950 ml Perfusion, Amber, BD Luer-Lok™ Concentric 1 ml 50 100 300139

Description BD Microlance™ Scale - Graduation Box content Case content Item numberNeedle Dimensions units units

50 ml, BD Luer-Lok™ 14G x 11/4" 1 ml 50 100 30013650 ml Amber, BD Luer-Lok™ 14G x 11/4" 1 ml 50 100 300138

General Description

� Leak-tight, even under high pressure (locking facilityon BD Luer-Lok™ syringes). Gradual and controlledmovement of plunger.

� Accuracy and safety of use: transparent body.

� Eccentric tip: reduces dead space when using largecapacity syringe.

� BD Luer-Lok™ - needle hub or extension line can besafely locked on the syringe.

� Catheter tip: permits attachment of a probe or other tubing.

� 100 ml syringes: catheter tip with potential to changeinto Luer tip via an adapter.

� Latex free

Specific Description of 50 ml opaque syringe� 50 ml opaque syringe for guaranteed protection of

photosensitive drugs: stops 90% of light rays between290-450 nm UV wave length.

Recommended uses� 50 ml syringes are particularly suitable for automatic

infusion equipment: syringe-drivers, pumps, etc...They have been approved for use with leading brands ofsyringe-driver.

Type of materials : see BD Plastipak™

Sterilisation method

� Ethylene oxide

� CE Marked

Page 22: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

OPAQUE and CLEARORAL SYRINGESBD™ Oral Syringes

Non Sterile, single use

Description Scale Case content Item numberunits

1 ml Amber 0.02 ml 500 3052073 ml Amber 0.1 ml 500 3052105 ml Amber 0.2 ml 500 30520810 ml Amber 0.2 ml 500 3052091 ml 0.02 ml 500 3052173 ml 0.1 ml 500 3052205 ml 0.2 ml 500 30521810 ml 0.2 ml 500 305219

DescriptionOral syringes with an oversized (non-luer) tip to preventconnection to IV access lines and mounting of hypodermicneedles, thus reducing the risk of parenteral administration oforal mecications.

� Amber coloured syringe protects light sensitive drugs.

� BD™ oral syringes supplied with leak-tight cap to prevent� loss of the medication contained in the syringe after

preparation.

Recommended uses� Specially designed for oral administration of drugs or fluids

in drinkable form.

� BD™ oral syringes provide the essential safety needed forthe central preparation of unit doses.

� Paediatric and geriatric departments

Type of materials� Barrel and plunger: Polypropylene

� Plunger stopper: Synthetic rubber (latex free)

� Lubricant: Silicone oil

� Protective cap: Polypropylene

� CE Marked

23Injection Systems

Page 23: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

24 Injection Systems

PREFILLED FLUSHINGDEVICESBD™ Saline

Single use

Description� Prefilled flushing devices containing saline

(isotonic NaCI 0.9%).

� Specially designed for flushing in-situ vascular accessdevices.

� Special design of syringe barrel - 3 ml and 5 ml syringesizes have the same barrel diameter as the 10 ml syringein order to ensure maintenance of low pressure during theflushing process.

� Standardised flush volumes.

� BD Luer-LokTM tip for secure connection to the catheter.

� Modified plunger and stopper design avoid venous reflux.

� Size and shape of the tip cap allow easy handling, andhelps avoiding touch contamination of the syringe Luerconnection.

� Eliminates the use of needles, thus reducing the potentialfor accidental needle stick injuries.

� BDTM Saline XS can be used on a sterile field.

� BDTM Saline SP must not be used on a sterile field.

Type of materialSaline composition:� Sterile, non pyrogenic, isotonic NaCl 0.9%

Syringe barrel and tip cap:� Specially formulated proprietary polypropylene resin

Stopper:� Latex free bromobutyl formulation

� Silicone lubricant - medical grade silicone oil

Plunger:� Polypropylene

Blister pack:� BDTM Saline XS - Polypropylene polyamide film, medical

grade paper

� BDTM Saline SP:

Pouch: plastic film

Box: corrugated cardbox

Shelf life� 3 years

� CE marked

� Terminally steam sterilized - sterility assurance level of 10-6

Description Box content Item numberunits

3 ml BD™ Saline SP 30 3065545 ml BD™ Saline SP 30 30655510 ml BD™ Saline SP 30 306556

BD™ Saline - Sterile Fluid Path

Description Box content Item numberunits

3 ml BD™ Saline XS 30 3065705 ml BD™ Saline XS 30 30657110 ml BD™ Saline XS 30 306572

BD™ Saline - EXternally Sterile

Page 24: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Injection Systems 25

Description Needle Dimensions Box content Item numberunits

1 ml 27G 1/2" - 0.4 x 13 mm 50 3057893 ml 25G 5/8" - 0.5 x 16 mm 50 3057813 ml 23G 1" - 0.6 x 25 mm 50 3057823 ml 22G 11/2" - 0.7 x 40 mm 50 3057833 ml 21G 11/2" - 0.8 x 40 mm 50 3057845 ml 22G 11/2" - 0.7 x 40 mm 50 30578510 ml 22G 11/2" - 0.7 x 40 mm 50 305786

SAFETY NEEDLESBD Eclipse™

Sterile, single use

Description� Patented BD SmartSlip™ technology especially designed

for safe assembling of BD Eclipse™ to luer syringes.

� Bevel oriented to the safety cover to allow low angleinjections.

� Activates with one finger stroke - no hard surface required.

� Minimal change in technique.

� No excess dead space - minimal medication waste.

� Needle-based design facilitates standardisation.

Safety� Audible click confirms safety assembled needle for safe

injection with luer syringes.

� Safety activation immediately follows injection.

� Wide, textured finger pad for thumb or forefinger.

� Audible click indicates safety activation.

� Needle remains safely locked inside activated cover.

� Single-handed activation.

Patient Care� Activation occurs after needle is withdrawn.

� BD Microlance™ needles minimise injection pain.

Sterilisation method� Ethylene oxide

� Item number 305789: Gamma Irradiation

� CE marked

Needle Dimensions Box content Item numberunits

30G 1/2" - 0.29 x 13 mm 50 30577127G 1/2" - 0.4 x 13 mm 50 30577025G 5/8" - 0.5 x 16 mm 50 30576023G 1" - 0.6 x 25 mm 50 30589221G 11/2" - 0.8 x 40 mm 50 30589521G 1" - 0.8 x 25 mm 50 30589420 G 1" - 0.9 x 25 mm 50 305899

BD Eclipse™ needles with BD SmartSlip™ technology

BD Eclipse™ needle with BD Luer-Lok™ syringes

BD Eclipse™ - a pivoting needle is the latest addition to the BD safety injection family, complementing BD’s existing needle-based portfolio.

Page 25: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

26 Injection Systems

SAFETY NEEDLES andSYRINGESBD SafetyGlide™

Description Needle Dimensions Box content Item numberunits

1 ml 27G 1/2" - 0.4 x 13 mm 100 3059451 ml 26G 3/8" - 0.45 x 10 mm 100 305946

BD SafetyGlide™ syringes with integrated needle

Description Needle Dimensions Box content Item numberunits

3 ml 25G 5/8" - 0.5 x 16 mm 50 3059043 ml 23G 1" - 0.6 x 25 mm 50 3059055 ml 22G 11/2" - 0.7 x 25 mm 50 30590710 ml 22G 11/2" - 0.7 x 25 mm 50 305908

BD SafetyGlide™ needle with BD Luer-Lok™ syringe

Description� Low profile safety mechanism remains discretely out of the

way before and during injection.

� Patented BD Activation Assist™ technology ensures quickcoverage of the needle by a single finger strokeimmediately after injection.

� Minimal change in technique.

� “Bevel up” design eliminates safety-arm interference tofacilitate low angle injections.

� No excess dead space - minimal medication waste.

� Needle-based design facilitates standardisation.

Description� Minimal change in technique.

� Rotating safety arm eliminates interference during drawingup and facilitates low angle injections.

� Permanently attached needle means minimal waste space.

� 26G and 27G needles perform a variety of subcutaneousand intradermal applications.

BD SafetyGlide™ syringes and needlesSafety� Safety activation immediately follows injection.

� Needle is safely protected after shielding.

� Single-handed activation.

Patient Care� Activation occurs after needle is withdrawn.

� BD Microlance™ needles minimise injection pain.

Sterilisation method� Gamma Irradiation

� CE marked

BD SafetyGlide™ syringes complement BD’s safety injection family with the Tiny Needle Technology (TNT) to the mostversatile safety injection technology

Page 26: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Injection Systems 27

SAFETY SYRINGESBD Integra™

BD Integra™ syringe with retracting needle combinesinnovative technology with BD quality and comfort.

Description� Spring based retracting syringe with detachable needle.

� Unique non-luer thread design - BD Tru-Lok™ of theBD Integra™ detachable needle provides:� Low waste space (0.026 ml against conventional

syringe dead space of 0.092 ml) - reducedmedication waste

� Secure connection

� Activation of retracting needle before or after needle iswithdrawn from the patient - clinician takes the decision.

� Complete dosing ensured prior to activation.

� No change in technique.

� BD Integra™ blunt needle allows change of needle foraspiration and administration.

Safety� Safety activation immediately follows injection.

� Needle is completely retracted into the syringe barrel.

Patient Care� Syringe and needle cannot be reused.

� BD PrecisionGlide™* needle minimises injection pain.

Description Box content Item numberunits

3 ml syringe only 100 305283

BD Integra™ syringe with retracting BD PrecisionGlide™*needle

Needle Dimensions Box content Item numberunits

25G x 5/8" - 0.5 x 16 mm 100 30531025G x 1" - 0.5 x 25 mm 100 30531123G x 1" - 0.6 x 25 mm 100 30531222G x 11/2" - 0.7 x 40 mm 100 305313

Description Box content Item numberunits

3 ml syringe with detachable 25G x 5/8" needle 100 3052693 ml syringe with detachable 25G x 1" needle 100 3052703 ml syringe with detachable 23G x 1" needle 100 3052713 ml syringe with detachable 22G x 11/2" needle 100 3052723 ml syringe with detachable 21G x 1" needle 100 3052733 ml syringe with detachable 21G x 11/2" needle 100 305274

BD Integra™ syringe

BD Integra™ retracting needles

Needle Dimensions Box content Item numberunits

18G x 11/2" - 1.25 x 40 mm 100 30527518G x 11/2" - 1.25 x 40 mm with 5 micron filter 100 305833

BD Integra™ blunt, non-retracting needles

* BD Precision Glide™ is the US brand for hypodermic needles corresponding to the European brand BD Microlance™.

Description Needle Dimensions Box content Item numberunits

1 ml TB 27G x 1/2" - 0.4 x 13 mm 100 3052981 ml TB 26G x 3/8" - 0.45 x 10 mm 100 3052791 ml 25G x 1" - 0.5 x 25 mm 100 3052781 ml 25G x 5/8" - 0.5 x 16 mm 100 3052771 ml insulin syringe U-100 29G x 1/2" - 0.33 x 13 mm 100 305282

BD Integra™ syringe with permanently attached BD PrecisionGlide™* needle

Page 27: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

28 Injection Systems

SHARPS DISPOSAL SYSTEMSBD™ Sharps Containers, Brackets & Accessories

Single use

Description� Functional ease of use - visible and audible locking systemto ensure proper assembly.

� Visible temporary and permanent closure features

� Temporary and permanent closure engagement withouttouching the access area

� Retention valve against spillage due to optimal containeropening for increased ease of disposal while restrictingaccess for safety.

� Manually inviololable when container is permanently locked.

� Clear visualisation fo the maximum fill line.

� Rounded corners to ensure optimal impact resistance ifdropped to avoid cracking.

� Accompanied by a range of brackets and accessoriesfocusing on “correct placements” and “secure fitment”.1

� BD™ Sharps Containers are made of polypropylene andmay be incinerated and autoclaved.

� Regulatory Compliance� compliant with the British Standard BS 7320 : 1990.2

� compliant with the French Standard NFX 30 - 500.3

� compliant with the UN Standard, UN 3291.4

Product Nominal Capacity Usable Capacity Box content Item number(Litre) (Litre) units

0.45 L Sharps Container 0.45 L 0.36 L 100 3024340.87 L Sharps Container 0.87 L 0.7 L 50 3672021.5 L Sharps Container 1.5 L 1.2 L 40 3056243.0 L Sharps Container 3.0 L 2.4 L 25 3056255.0 L Sharps Container 5.0 L 4.0 L 20 3056267.0 L Sharps Container 7.0 L 5.6 L 16 30562722.7 L Sharps Container 22.7 L 18.2 L 12 300479

1 “Selecting, Evaluating and Using Sharps Disposal Containers” CDC NIOSHPublication NO. 97-111.

BD™ Sharps Disposal Systems - focused on “Safety”

The new range of BD™ Sharps Disposal Containers is designed to optimise “point of use” disposal to help reduce the risks ofblood exposure and needle stick injuries associated with the disposal process.

2 Not for BD™ Sharps Container 0.87 L3 Not for BD™ Sharps Containers 0.45 L and 22.7 L4 Not for BD™ Sharps Containers 0.87 L and 22.7 L

NextGene

ration

Brackets Supports & Description Box content Item numberAccessories units0.87 L Metal Cup Bracket Metal cup bracket for placement on horizonatal surfaces. 50 3059700.45 L Desktop Bracket Plastic bracket for placement on horizontal surfaces. 12 3059641.5 L Desktop Bracket Multipurpose metal bracket suitable for placement on 6 3056453.0 L Desktop Bracket horizontal surfaces, secure wall mounting and fastened 6 3052505.0 L Desktop Bracket to a rail with the use of an adaptor. 6 3052537.0 L Desktop Bracket 6 3052551.5 L Hanging Bracket Metal bracket suitable for attaching to medication carts. 6 3057103.0 L Hanging Bracket 6 3052515.0 L Hanging Bracket 6 3052527.0 L Hanging Bracket 6 305254Universal Adopter (small) Suitable for attaching all desktop brackets to rails or countertops for 6 305636Universal Adopter (large) space saving efficiency. 6 305637Replacement Suction Cups For secure fitment of all horizontally mounted desktop brackets. 8 305968

Page 28: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Injection Systems

RE-USE PREVENTION...the situation...

29

Infections due to Percent of Disease Attributable Healthy Live YearsReused Equipment to Reused Equipment Lost

Hepatitis B 22 million 32% 3.1 millionHepatitis C 2 million 40% 300.000HIV 260.000 5% 5.7 million

16 billion injections are administered worldwide every year. In the developing world, as many of 40% of these aregiven with reused syringes - exposing those seeking medical care to possible infection with the viruses that causeHIV/AIDS, hepatitis B and hepatitis C.

Some syringe reuse is intentional due to economics or lack of proper training and education. Other reuse isunwitting: in some regions of the world, used syringes are repackaged and resold - appearing to be brand-new tothe unsuspecting healthcare worker.

This practice spreads bloodborne diseases such as HIV/AIDS, hepatitis B and hepatitis C. The impact of theseunsafe injections in terms of lives lost and destroyed is enormous.

Burden of Disease Due to Reused Injection Syringes in 20002

Proportion of injections given with reused equipment1

1 World Health Organization (WHO) and Centers for Disease Control (CDC), 2002. Waste image provided by WHO.

2 WHO Global Burden of Disease Study, 2000, as cited in “A Procurement Guide: Procuring Single-use Injection Equipment and Safety Boxes”,April 24, 2003, WHO

70%

30%

75%

18%30%

Page 29: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

30 Injection Systems

RE-USE PREVENTIONSYRINGESBD SoloMed™ 2-piece syringes

Single use

BD SoloMed™ syringes with breakable plunger are the latestaddition to the BD reuse prevention injection family.

Description� Allows clinician to perform all procedures for therapeutic

treatment.

� Places the ability to permanently disable the syringe in theclinician’s hand.

� Prevents downstream reuse effectively.

� Audible “click” sound reassures the patient and clinicianthat the syringe is destroyed and can no longer be reused.

� Requires minimal change in technique and thus does notinterfere in the medical procedure.

� Minimal waste space - equivalent to a conventionalBD syringe.

� Clear barrel makes it easy to see the syringe contents andadjust correct dose.

� High quality BD Microlance™ needle for greater patientcomfort.

� Individually blister packed.

Sterilisation method� Ethylene oxide

� WHO approved and CE marked

Description Tip Scale Box content Item numberunits

2 ml Luer Slip Concentric 0.1 ml 100 3026545 ml Luer Slip Eccentric 0.2 ml 100 30265510 ml Luer Slip Eccentric 0.5 ml 100 302758

BD SoloMed™ 2-piece syringes with breakable plunger

Description BD Microlance™ Box content Item numberNeedle Dimensions units

2 ml Luer Slip 25G 5/8" - 0.5 x 16 mm 100 3026502 ml Luer Slip 24G 1" - 0.55 x 25 mm 100 3026922 ml Luer Slip 23G 1" - 0.6 x 25 mm 100 3026402 ml Luer Slip 23G 11/4" - 0.6 x 30 mm 100 3026905 ml Luer Slip 23G 1" - 0.6 x 25 mm 100 3026425 ml Luer Slip 23G 11/4" - 0.6 x 30 mm 100 3026965 ml Luer Slip 22G 11/4" - 0.7 x 30 mm 100 3026955 ml Luer Slip 21G 11/2" - 0.8 x 40 mm 100 30265810 ml Luer Slip 21G 11/2" - 0.8 x 40 mm 100 302761

BD SoloMed™ 2-piece syringes with breakable plunger and needles packed aside

Page 30: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

RE-USE PREVENTION SYRINGESBD SoloMed™ 3-piece syringes

Single use

Description� Allows clinician to perform all procedures for therapeutic

treatment.

� Places the ability to permanently disable the syringe in theclinician’s hand.

� Prevents downstream reuse effectively.

� Audible “click” sound reassures the patient and clinicianthat the syringe is destroyed and can no longer be reused.

� Requires minimal change in technique and thus does notinterfere in the medical procedure.

� Minimal waste space - equivalent to a conventional BDsyringe.

� Clear barrel makes it easy to see the syringe contents andadjust correct dose.

� BD Microlance™ needle for patient comfort.

� Individually blister packed.

Sterilisation method� Ethylene oxide

� WHO approved and CE marked

Description Tip Scale Box content Item numberunits

3 ml Luer Slip Concentric 0.1 ml 100 3026725 ml Luer Slip Eccentric 0.2 ml 100 30267810 ml Luer Slip Eccentric 0.5 ml 100 302683

BD SoloMed™ 3-piece syringes with breakable plunger

Description BD Microlance™ Box content Item numberNeedle Dimensions units

3 ml Luer Slip 25G 5/8" - 0.5 x 16 mm 100 3027073 ml Luer Slip 23G 11/4" - 0.6 x 30 mm 100 3027083 ml Luer Slip 22G 11/2" - 0.7 x 40 mm 100 3026075 ml Luer Slip 23G 11/4" - 0.6 x 30 mm 100 3027115 ml Luer Slip 21G 11/2" - 0.8 x 40 mm 100 30270910 ml Luer Slip 21G 11/2" - 0.8 x 40 mm 100 302721

BD SoloMed™ 3-piece syringes with breakable plunger and needle packed aside

Description Tip Scale Box content Item numberunits

3 ml BD Luer-Lok™ Concentric 0.1 ml 100 3026565 ml BD Luer-Lok™ Concentric 0.2 ml 100 30265710 ml BD Luer-Lok™ Concentric 0.5 ml 100 302684

BD SoloMed™ 3-piece syringes with breakable plunger

Description BD Microlance™ Box content Item numberNeedle Dimensions units

3 ml BD Luer-Lok™ 25G 5/8" - 0.5 x 16 mm 100 3026443 ml BD Luer-Lok™ 23G 1" - 0.6 x 25 mm 100 3026413 ml BD Luer-Lok™ 23G 11/4" - 0.6 x 30 mm 100 3027043 ml BD Luer-Lok™ 22G 11/2" - 0.7 x 40 mm 100 3027185 ml BD Luer-Lok™ 23G 1" - 0.6 x 25 mm 100 3026435 ml BD Luer-Lok™ 23G 11/4" - 0.6 x 30 mm 100 3027425 ml BD Luer-Lok™ 21G 11/2" - 0.8 x 40 mm 100 30264510 ml BD Luer-Lok™ 21G 11/2" - 0.8 x 40 mm 100 302729

BD SoloMed™ 3-piece syringes with breakable plunger and needle packed aside

Injection Systems 31

Page 31: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Injection Systems32

RE-USE PREVENTION SYRINGESWITH SAFETY NEEDLE SHIELD

Single use

Description Tip Scale Box content Item numberunits

3 ml Luer Slip Concentric 0.1 ml 100 3026745 ml Luer Slip Eccentric 0.2 ml 100 30268010 ml Luer Slip Eccentric 0.5 ml 100 302686

BD SoloMed™ 3-piece syringes with breakable plunger and safety needle shield*

BD SoloMed™ 3-piece syringes

Description BD Microlance™ Box content Item numberNeedle Dimensions units

3 ml Luer Slip 22G 11/2" - 0.7 x 40 mm 100 3027123 ml Luer Slip 23G 11/4" - 0.6 x 30 mm 100 3027135 ml Luer Slip 21G 1" - 0.8 x 25 mm 100 3026825 ml Luer Slip 21G 11/2" - 0.8 x 40 mm 100 30271510 ml Luer Slip 21G 11/2" - 0.8 x 40 mm 100 302688

BD SoloMed™ 3-piece syringes with breakable plunger and safety needle shield with mounted needles*

Description Tip Scale Box content Item numberunits

3 m BD Luer-Lok™ Concentric 0.1 ml 100 3026735 ml BD Luer-Lok™ Concentric 0.2 ml 100 30267910 ml BD Luer-Lok™ Concentric 0.5 ml 100 302685

BD SoloMed™ 3-piece syringes with breakable plunger and safety needle shield*

Description BD Microlance™ Box content Item numberNeedle Dimensions units

3 ml BD Luer-Lok™ 25G 5/8" - 0.5 x 16 mm 100 3024783 ml BD Luer-Lok™ 23G 1" - 0.6 x 25 mm 100 3027755 ml BD Luer-Lok™ 23G 11/4" - 0.6 x 30 mm 100 3027735 ml BD Luer-Lok™ 23G 11/2" - 0.6 x 40 mm 100 3024695 ml BD Luer-Lok™ 22G 11/2" - 0.7 x 40 mm 100 3024685 ml BD Luer-Lok™ 21G 11/2" - 0.8 x 40 mm 100 30246710 ml BD Luer-Lok™ 21G 11/2" - 0.8 x 40 mm 100 302639

BD SoloMed™ 3-piece syringes with breakable plunger and safety needle shield with mounted needles*

* Please contact your local sales representative for product availability.

BD SoloMed™ with a syringe-based safety shield to addressboth reuse prevention and prevention of accidental needlestick to healthcare workers.

Description� Prevents downstream reuse effectively.

� Audible click sound confirms the broken plunger.

� Rotating saftey shield is designed to accommodate low-angle injections.

� After activation the safety shield is securely covering thecontaminated needle

� Needle remains safely locked inside activated cover.

� Single-handed activation

Sterilisation method

� Ethylene oxide

� WHO approved and CE marked

Page 32: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

AUTO-DISABLESYRINGESBD SoloShot™

Single use

Description Needle Dimensions ISO Colour Code Box content Item numberunits

0.5 ml 23G 1" - 0.6 x 25 mm Blue 200 3018600.5 ml 24G 3/4" - 0.55 x 19 mm Violet 200 3018890.5 ml 25G 1" - 0.5 x 25 mm Orange 200 3018650.5 ml 25G 5/8" - 0.5 x 16 mm Orange 200 3018871.0 ml 22G 1" - 0.7 x 25 mm Black 200 301888*

BD SoloShot™ IX - Auto-disable syringe with integrated needle

* please contact your local sales representative for product availability

Description Needle Dimensions Box content Item numberunits

0.05 ml 27G 3/8" - 0.4 x 10 mm 100 3017920.1 ml 27G 3/8" - 0.4 x 10 mm 100 3017930.05 ml - 0.10 ml combo 27G 3/8" - 0.4 x 10 mm 100 303212

BD SoloShot™ LX - BCG Auto-disable syringe with integrated needle

� Special design for fixed-dose injections.

� ISO colour-coded, tamper resistant plunger rods for easyidentification of correct needle gauge.

� Small size, few components, no rubber stopper.

� Pre-set volume limit (0.5 or 1.0 ml) and bold single scalemarkings.

Sterilisation method� Ethylene oxide

� CE marked

BD SoloShot™ Auto-Disable SyringesDescription� Specially designed injection device for both large-scale

and routine immunization programmes or any other fixed-dose injections.

� Highly effective in preventing the re-use of syringes due to:

� Clinically proven Passive Activation Auto-Disablemechanism featuring the patented V-Clip design - whendrawing up the vaccine the auto-disable mechanism isautomatically activated and after injection of the vaccineinto the patient the syringe is blocked and cannot bereused any longer.

� Permanently attached needle.

� High-quality BD Microlance™ needle for greater patientcomfort.

� Minimal dead space guaranteeing minimal vaccinewastage.

� Bold single scale markings for easy and accurate dosemeasurement.

� Low injection forces for greater patient comfort.

� Individual blister packaging ensuring sterility.

� WHO approved and CE marked.

� Special design for fixed low-dose vaccinations.

� Pre-set volume limit (0.05 or 0.10 ml) and bold single scalemarkings.

� BD Microlance™ needle 27G 3/8"with intradermal bevel

Sterilisation method� Gamma Irradiation

� CE marked

Injection Systems 33

Page 33: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

34 Injection Systems

RE-USE PREVENTIONBD™ Hub Cutter

Single use

Safety Box for Disposal of Hypodermic Needles

Description� Portable, disposable, point-of-use needle hub destruction

device.

� Designed to cut the syringe needle at the hub and enclosethe needle securely in the hard plastic container.

� Cuts and holds 400-600 needles, depending on needlesizes.

� Ready for use.

� Separates needles and syringes at the point of use.

� Large opening and surrounding wall facilitate needleinsertion.

� Compact and lightweight design.

� Puncture-resistant container.

� Designated fill line.

� Yellow colour - colour coding for biohazardous waste.

� Container cap can be closed between uses.

� Container cap can be permanently locked prior to disposal.

� Disposal of entire container avoids contact with sharps.

� Easy to dispose - can be incinerated or buried in a pit.

� Compatible with BD SoloShot™, BD SoloMed™ and anyconventional syringes up to 50 ml.

BD™ Hub CutterDescription Fill capacity Box content Item number

unitsBD™ Hub Cutter for hypodermic needles in average 400-600 needles 32 305307BD™ Hub Cutter for hypodermic needles (Russian Label) in average 400-600 needles 32 305309

Page 34: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

DIA

BE

TES

CA

RE

Page 35: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

INSULIN SYRINGESBD Micro-Fine™ Plus

Sterile, single use

36 Diabetes Care

Description CE marked Box content Case content Item numberunits units

1 ml U-100, 29G x 12,7 mm no 100 500 3209091 ml U-100, 29G x 12,7 mm yes 100 500 3209311 ml U-100, 30G x 8 mm no 100 500 3209291 ml U-100, 30G x 8 mm yes 100 500 3209350.5 ml U-100, 29G x 12,7 mm no 100 500 3209210.5 ml U-100, 29G x 12,7 mm yes 100 500 3209320.5 ml U-100, 30G x 8 mm no 100 500 3209300.5 ml U-100, 30G x 8 mm yes 100 500 3209331 ml U-40, 29G x 12,7 mm no 100 500 3209101 ml U-40, 30G x 8 mm no 100 500 3209110,3 ml U-100 , 30G x 8 mm, 1/2 step units no 100 500 320829

BD Micro-Fine™ Plus Insulin Syringes

Description� A whole range of insulin syringes adapted to the indiviudal

needs and preferences of insulin injectors.

� Integrated needle, engineered with optimal point geometryfor maximum comfort and reliability.

� BD Micro-Fine Plus insulin syringes offer a high injectioncomfort with a triple bevel that is designed to reduce thepenetration force required to puncture the skin.

� For sterile and single use only.

Page 36: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Diabetes Care

PEN NEEDLESBD Micro-Fine™ Plus

Sterile, single use

37

Description CE marked Box content Case content Item numberunits units

29G (0,33 x 12,7 mm) no 100 1200 32048029G (0,33 x 12,7 mm) yes 100 1200 32051630G (0,30 x 8 mm) no 100 1200 32051930G (0,30 x 8 mm) yes 100 1200 32051731G (0,25 x 5 mm) no 100 1200 32059031G (0,25 x 5 mm) yes 100 1200 320518

BD Micro-Fine™ Plus Pen Needles

Description� Integrated needle, engineered with optimal point geometry

for maximum comfort and reliability together with an idealrange of gauges and sizes.

� New Thin Wall technology provides soft and reliablesubcutaneous delivery of insulin for all types of patients(available for 30G and 31G pen needles). The needleretains its extremely fine external dimension but has awider, increased inner diameter. The result is an improvedinsulin flow rate and a lower force that is required to pushthe pen injector's plunger.

� For sterile and single use only.

� Compatible with all leading insulin injection pens (Eli Lilly*,Sanofi-Aventis**, Novo Nordisk***, Owen Mumford****),BD Micro-Fine™ Plus is the simple and natural choice forhealthcare professionals and users alike.

Needle Lubrication� Each and every BD Micro-Fine™Plus needle is lubricated

using a technique and formula that is proprietary to BD.The purpose is to place a microscopic film of lubricant overthe needle. This film greatly reduces the drag force of theneedle through the skin and the result is a significantlyimproved injection comfort.

* Eli Lilly is a trademark of Eli Lilly

** Sanofi-Aventis is a trademark of Sanofi-Aventis

*** Owen Mumford is a trademark of Owen Mumford

****Novo Nordisk is a trademark of Novo Nordisk

Page 37: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

INFU

SIO

NTH

ER

AP

Y

Page 38: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

40 Infusion Therapy

PERIPHERAL IV CATHETERwith INJECTION VALVE andOBTURATORBD Venflon™

Sterile, single use

Gauge Length Catheter ext. Colour Box content BD Venflon™ Catheter BD Venflon™ ObturatorCatheter mm diameter mm units Item number Item number22G 25 0.8 Blue 50 391451 39425120G 32 1.0 Pink 50 391452 39425218G 32 1.2 Green 50 391457 39425718G 45 1.2 Green 50 391453 39425317G 45 1.4 White 50 391454 39425416G 45 1.7 Grey 50 391455 39425514G 45 2.0 Orange 50 391456 394256

Description

� BD Venflon™ intravenous catheter with integrated injectionport and valve for peripheral catheterisation.

� Permits needle-free administration of bolus medicationsduring infusion.

� Back-cut needle bevel and tapered end of the PTFEcatheter allows easier insertion and minimises the risks ofvein damage.

� Wing position reduces the risk of bacterial contaminationby preventing any direct contact between the rear of thecatheter hub and the skin. Utilising the wings, immobility ofthe catheter can be further ensured by the application ofthe BD Veca-C™ and BD Veca-Fix™ IV dressing.

� BD Luer-Lok™ compatible.

� The Obturator protects the inner lumen of the catheterfrom coagulation and thrombus formation afterdiscontinuation of infusion.

� The Obturator is colour coded to match the correspondingcatheter gauge.

Sterilisation method

� Ethylene oxide

Shelf life

� 5 years

� CE marked

� Latex free

Page 39: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

41Infusion Therapy

Gauge Length Catheter ext. Colour Box content BD Venflon™ Pro Catheter BD Venflon™ ObturatorCatheter mm diameter mm units Item number Item number22G 25 0.9 Blue 50 393202 39425120G 32 1.1 Pink 50 393204 39425218G 32 1.3 Green 50 393206 39425718G 45 1.3 Green 50 393207 39425317G 45 1.5 White 50 393208 39425416G 45 1.8 Grey 50 393209 39425514G 45 2.0 Orange 50 393210 394256

PERIPHERAL IV CATHETERwith INJECTION VALVE andOBTURATORBD Venflon™ Pro

Sterile, single use

Manufactured in BD Vialon™, a unique polyurethane,radiopaque biocompatible catheter material (please seepage 128 for further information).

Description

� Design based on the clinically proven BD Venflon™platform and has an integrated injection port.

� The improved design of the injection port cap ensureseasy opening and secure closing, whilst avoiding touchcontamination of the injection port and valve.

� Improved insertion characteristics as BD Vialon™ makes itpossible to manufacture a catheter with a better tapered,stronger and more reliable tip geometry which improvesthe chances of a first cannulation attempt success andalso reduces the risk of thrombophlebitis.

� Although the catheter material is rigid before insertion, thequalities of BD Vialon™ allow for softening of the cathetermaterial once it is inside the body, again reducing the riskof thrombophlebitis.

� There is an improved flow rate when compared withTeflon™ catheters as BD Vialon™ allows for a largerinternal diameter.

� BD Luer-Lok™ compatible.

� Obturator range available.

� The Obturator protects the inner lumen of the catheterfrom coagulation and thrombus formation afterdiscontinuation of infusion.

� The Obturator is colour coded to match the correspondingcatheter gauge

Sterilisation method

� Irradiation

Shelf life

� 3 years

� CE marked

� Latex free

Page 40: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

42 Infusion Therapy

PERIPHERAL SAFETY IV CATHETERwith INJECTION VALVE andOBTURATORBD Venflon™ Pro Safety

Sterile, single use

Description

� BD Venflon™ Pro Safety needle protected IV Cannulacombines all the advantages of the original BD Venflon™Pro, with second generation safety protection featuresagainst needlestick injuries.

� Familiar ported design with ‘snap-cap’ aids non-touchtechnique which helps prevent port being inadvertently leftopen.

� Sharp needle technology provides both ease ofpenetration and improved patient comfort.

� Flexible wings stabilise the cannula in the vein and providecomfortable securement for the patient.

� Needle shield- Once activated, the needle tip is fully encapsulated

inside the protection mechanism, which is designedto minimise the risk of scratching yourself

- The unique design captures residual blood safelywithin the device, thereby minimizing the risk ofunanticipated blood splatter during and afteractivation

- with needle safely encased in smooth edged plasticshield

� The Obturator protects the inner lumen of the catheterfrom coagulation and thrombus formation afterdiscontinuation of infusion.

� The Obturator is colour coded to match the correspondingcatheter gauge

� Grip is ergonomically designed to allow for a variety ofuser techniques and to aid insertion.

� BD Venflon™ Pro Safety is designed for use in all

departments and provides a full range of features to suitmost clinincal indications.

Sterilisation method

� Irradiation

Shelf life

� 3 years

� CE marked

� Latex free

Manufactured in BD Vialon™, a unique polyurethane,radiopaque biocompatible catheter material (please seepage 128 for further information).

NextGene

ration

GaugeCatheter

Lenghtmm

CatheterO.D. mm

CatheterI.D. mm Colour Box content

units

BD Venflon™ ProSafety CatheterItem number

BD Venflon™ObturatorItem number

22G 25 0.9 0.6 Blue 50 393222 39425120G 32 1.1 0.8 Pink 50 393224 39425218G 32 1.3 1.0 Green 50 393226 39425718G 45 1.3 1.0 Green 50 393227 39425317G 45 1.5 1.2 White 50 393228 39425416G 45 1.8 1.4 Grey 50 393229 39425514G 45 2.0 1.6 Orange 50 393230 394256

Page 41: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

43Infusion Therapy

BD Angiocath™

Sterile, single use

PERIPHERAL IV CATHETER

Gauge Length Catheter ext. Colour Box content BD Angiocath™Catheter mm diameter mm units Item number24G 19 0.7 Yellow 50 38111222G 25 0.9 Blue 50 38112320G 48 1.1 Pink 50 38113720G 30 1.1 Pink 50 38113418G 48 1.3 Green 50 38114718G 30 1.3 Green 50 38114416G 48 1.7 Grey 50 38115716G 30 1.7 Grey 50 38115414G 48 2.1 Orange 50 38116714G 30 2.1 Orange 50 381164

Description

� Catheter made of radiopaque FEP Polymer.

� Catheter with thermo-moulded bevel ensures excellentpenetration properties.

� Triple-bevel needle.

� Crystal clear flashback chamber.

� Complete gauge range from 10G x 76 mm to24G x 19 mm.

� Available in longer lengths (14G and 16G available with83 mm and 133 mm long catheters).

� BD Luer-Lok™ compatible.

Recommended uses

� Infusion

� Transfusion

� Angiography

Sterilisation method

� Ethylene oxide

Shelf life

� 5 years

� CE marked

� Latex free

NB: Diameters 12G and 10G permit very large volumeemergency infusions

Standard lengths

Gauge Length Catheter ext. Colour Box content BD Angiocath™Catheter mm diameter mm units Item number16G 83 1.7 Grey 50 38225816G 133 1.7 Grey 50 38225914G 83 2.1 Orange 50 38226814G 133 2.1 Orange 50 38226912G 76 2.8 Light Blue 50 38227710G 76 3.4 Tan 50 382287

Special lengths

Page 42: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Gauge Length Catheter ext. Colour Box content BD Insyte™ without wings BD Insyte-W™ with wings BD Insyte™ and BD Insyte-W™Catheter mm diameter mm units Item number Item number Obturator Item number24G 19 0.7 Yellow 50 381212 381312 -22G 25 0.9 Blue 50 381223 381323 39428020G 48 1.1 Pink 50 381237 381337 39428220G 30 1.1 Pink 50 381234 381334 39428118G 45 1.3 Green 50 381246 381346 39428418G 30 1.3 Green 50 381244 381344 39428316G 45 1.7 Grey 50 381257 381357 39428514G 45 2.1 Orange 50 381267 - 394286

PERIPHERAL IV CATHETERWITH and WITHOUT WINGS andOBTURATORBD Insyte™, BD Insyte-W™

Sterile, single use

44 Infusion Therapy

Manufactured in BD Vialon™, a unique polyurethane,radiopaque biocompatible catheter material (please seepage 128 for further information).

The BD Insyte™ catheter provides exceptional penetrationcharacteristics, tip integrity and flow rates with improvedindwell times.

Description� Easy insertion: the strength of BD Vialon™ makes it

possible to manufacture a catheter with a finer, stronger,more reliable tip, giving excellent penetrationcharacteristics.

� Catheter tip integrity: the mechanical properties ofBD Vialon™ prevent twisting and deterioration of thecatheter tip geometry.

� The catheter is rigid before insertion but becomes softinside the body. This unique feature adds to thebiocompatibility of BD Vialon™ and results in a lower riskof complications.

� Flow rate: BD Insyte™ is a thin-walled catheter with ahigher flow-rate than other catheters of the same gauge.BD Vialon™ has good kink resistance and kink recovery toensure an optimum flow rate.

� BD Luer-Lok™ compatible.

Description of Obturator� Made of polyethylene

� Suits the catheter size (diameter and length), colour coded

Recommended use� Oncology

� Low venous pressure

� Fragile veins

Packaging� Packed individually in sterile peel-back ‘blister packs’

Sterilisation method� Ethylene oxide

Shelf life� 5 years

� CE marked

� Latex free

Page 43: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Infusion Therapy 45

SAFETY PERIPHERAL IVCATHETER and OBTURATORBD Insyte™ Autoguard™

Sterile, single use

Manufactured in BD Vialon™, a unique polyurethane,radiopaque biocompatible catheter material (please seepage 128 for further information).

The BD Insyte™ Autoguard™ catheter provides increasedsafety against accidental needle sticks as well as exceptionalpenetration, tip integrity and flow rates with improved indwelltimes

Description� Patented safety mechanism activation.

� The push-button holds the needle unit in the extendedposition until the user activates the mechanism.

� Pressing the push-button releases the spring so that theneedle/flashback chamber retracts into the safety barrel.

� BD Luer-Lok™ compatible.

Sterilisation method� Ethylene oxide

Shelf life� 3 years

Obturator� see BD Insyte™ range

� CE marked

� Latex free

GaugeCatheter

Lengthmm

Cathether ext.diameter mm Colour Box content

units

BD Insyte™ Autoguard™without wingsItem Number

BD Insyte™ Autoguard™without wings

Future Item Number

BD Insyte™Autoguard™ Winged

Item Number

BD Insyte™Autoguard™ WingedFuture Item Number

24G 19 0.7 Yellow 50 381412 381812* 381512 381912*

22G 25 0.9 Blue 50 381423 381823* 381523 381923*

20G 51 1.1 Pink 50 381437 381437** 381537 381537**

20G 32 1.1 Pink 50 381434 381834* 381534 381934*

18G 51 1.3 Green 50 381447 381447** 381547 381547**

18G 32 1.3 Green 50 381444 381844* 381544 381944*

16G 51 1.7 Grey 50 381457 381457** 381557 381557**

14G 51 2.1 Orange 50 381467 381467** - -

*= available October 2008**= no change of code

Page 44: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

46 Infusion Therapy

PERIPHERAL NEONATAL ANDPAEDIATRIC CATHETERSBD Neoflon™

Sterile, single use

Description

� 24G and 26G PTFE catheter.

� BD Neoflon™ is specially designed for the puncture ofsmall fragile vessels, frequently encountered in paediatricsor elderly patients.

� The unique design of the detachable wing holder makesthe catheter easier to hold, using either a ported or non-ported grip, despite its small size.

� The flexible wings facilitate secure fixation, even on thehand or arm of the neonate without the need to immobilisethe limb whilst at the same time reducing the risk ofmechanical phlebitis.

Sterilisation method

� Ethylene oxide

Shelf life

� 5 years

� CE marked

� Latex free

Gauge Length Catheter ext. Colour Box content Case content BD Neoflon™Catheter mm diameter mm units units Item number24G 19 0.7 Yellow 50 500 39135026G 19 0.6 Violet 50 500 391349

Page 45: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Infusion Therapy 47

PERIPHERAL NEONATAL andPAEDIATRIC IV CATHETERBD Insyte-N™

Sterile, single use

Manufactured in BD Vialon™, a unique polyurethane,radiopaque biocompatible catheter material (please seepage 128 for further information).

Description

� The BD Insyte-N™ needle incorporates a notch at the tipof the needle permitting instant blood flashbackconfirmation facilitating correct positioning in the vein.

� With or without flexible wings.

� 14 mm long, the shortest on the market to accomodatesmall vein segments and provides a greater choice ofinsertion sites.

� Shorter length provides increased flow rates.

� 24G for catheterisation in every situation encountered inneonatology, paediatrics, oncology and elderly patient.

� BD Luer-Lok™ compatible.

Recommended uses� Fragile veins, e.g. neonatology

� Low venous pressure

Packaging� Packed individually in sterile peel-back ‘blister packs’

Sterilisation method� Ethylene oxide

Shelf life� 5 years

� CE marked

� Latex free

Gauge Length Catheter ext. Colour Box content BD Insyte-N™ BD Insyte-N™ with wingsCatheter mm diameter mm units Item number Item number24G 14 0.7 Yellow 50 381211 -24G 14 0.7 Yellow 50 - 381311

Page 46: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

48 Infusion Therapy

SAFETY PERIPHERAL NEONATALand PAEDIATRIC IV CATHETERBD Insyte-N™ Autoguard™

Sterile, single use

Manufactured in BD Vialon™, a unique polyurethane,radiopaque biocompatible catheter material (please seepage 128 for further information).

Description� The BD Insyte-N™ Autoguard™ needle incorporates a

notch at the tip of the needle permitting instant bloodflashback confirmation facilitating correct positioning in thevein.

� Patented safety mechanism activation.

� With or without flexible wings.

� 14 mm long, the shortest on the market to accomodatesmall vein segments and provides a greater choice ofinsertion sites.

� Shorter length provides increased flow rates.

� 24G for catheterisation in every situation encountered inneonatology, paediatrics, oncology and elderly patient.

� BD Luer-Lok™ compatible.

Recommended uses� Fragile veins, e.g. neonatology

� Low venous pressure

Packaging� Packed individually in sterile peel-back ‘blister packs’

Sterilisation method� Ethylene oxide

Shelf life� 3 years

� CE marked

� Latex free

Gauge Length Catheter ext. Colour Box content BD Insyte-N™ Autoguard™ BD Insyte-N™ Autoguard™ with wingsCatheter mm diameter mm units Item number Item number24G 14 0.7 Yellow 50 381411 -24G 14 0.7 Yellow 50 - 381511

Page 47: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

49Infusion Therapy

PERIPHERAL IV CATHETERwith integrated INFUSION SETBD Intima™ and BD Intima™ Y

Sterile, single use

Gauge Length Catheter ext. Colour Box content BD Intima™ BD Intima™ YCatheter mm diameter mm units Item number Item number24G 19 0.7 Yellow 25 383211 38321322G 19 0.8 Blue 25 383221 38322320G 25 1.1 Pink 25 383234 38323618G 25 1.3 Green 25 383244 383246

Manufactured in BD Vialon™, a unique polyurethane,radiopaque biocompatible catheter material (please seepage 128 for further information).

Description

� The flexible extension tubing of BD Intima™ enables allother procedures to be carried out at a distance from thepuncture site, thus reducing the risk of thrombophlebitisand sepsis. BD Intima™ could therefore be left in placelonger than a conventional catheter.

Special features

� Straight BD Intima™ is fitted with a BD Luer-Lok™connector for connection to any piece of equipment fittedwith a Luer adapter.

� The BD Intima™ Y is fitted with a “Y” type adapter so thatthe injection site can be used for bolus administration ofmedication.

� Integrated injection port.

� Blood contact is avoided during insertion.

Recommended uses

� Fragile veins (paediatrics, geriatrics, oncology etc).

� Catheterisation without blood contact (infectious diseases).

Packaging

� Packed individually in sterile peel-back ‘blister packs’

Sterilisation method

� Ethylene oxide

Shelf life

� 5 years

� CE marked

� Latex free

Page 48: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

50 Infusion Therapy

SAFETY PERIPHERAL IV CATHETERwith integrated INFUSION SETBD Saf-T-Intima™

Sterile, single use

Gauge Length Catheter ext. Colour Box content BD Saf-T-Intima™ BD Saf-T-Intima™ YCatheter mm diameter mm units Item number Item number24G 19 0.7 Yellow 25 383312 38331322G 19 0.8 Blue 25 383322 38332320G 25 1.1 Pink 25 383335 38333618G 25 1.3 Green 25 - 383346

Manufactured in BD Vialon™, a unique polyurethane,radiopaque biocompatible catheter material (please seepage 128 for further information).

Description� Has the same flexible extension tubing of BD Intima™

that enables all other procedures to be carried out at adistance from the puncture site, thus reducing the risk ofthrombophlebitis and sepsis. BD Intima™ could thereforebe left in place longer than a conventional catheter.

Special features� The BD Saf-T-Intima™ is equipped with a needle

protection device that pulls the needle into a safety barrelas soon as the needle is removed. This minimises the riskof accidental needle stick injuries.

� BD Saf-T-Intima™ is fitted with a BD Luer-Lok™ connectorfor connection to any piece of equipment fitted with a Lueradapter.

� The BD Saf-T-Intima™ Y is fitted with a “Y” type adapterso that the injection site can be used for bolusadministration of medication.

� Removable injection port.

� Blood contact is avoided during insertion.

Sterilisation method� Ethylene oxide

Shelf life� 4 years

� CE marked

� Latex free

Page 49: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Infusion Therapy 51

CLOSED IV CATHETERSYSTEMBD Nexiva™ Standard Version

Sterile, single use

BD Nexiva™ Standard Version

Manufactured in BD Vialon™, a unique polyurethane,radiopaque biocompatible catheter material (please seepage 128 for further information).

Description� The BD Nexiva™ Closed IV Catheter System is a pre-

assembled configuration which combines separate IVcomponents into a single device.

� It promotes greater efficiency and convenience with lesshandling time, reduces the potential for blood leakage,helping to minimise clean-up.

� Pre-attached extension tubing and soft wings reducemanipulation at the insertion site to help decrease the riskof mechanical phlebitis and irritation to the vein.

� BD Nexiva™ Closed IV Catheter System incorporates thesharp BD needle technology and patented cannula tippingprocess, helping to reduce the pain of insertion.

Special features.S� BD Instaflash™ Needle Technology provides immediate

visual confirmation of vessel entry for improved first-sticksuccess

� Additional assurance of vessel entry through continuousflashback and clear vissibility of blood flow along theextension tubing

� Passive needle protection device reduces the potential forneedlestick injuries. Needle tip is automatically shieldedwhen withdrawn from the cannula to ensure compliance.Shield remains in place and cannot be bypassed.

� Closed fluid flow path reduces the potential for bloodleakage, thereby reducing clinicians’ exposure tobloodbourne pathogens.

Sterilisation method� Ethylene oxide

Shelf life� 3 years

� CE marked

� Latex free

Next Ge

neration

GaugeCatheter

Lengthmm Colour

Flow RateH20 (ml/min)

current

Flow RateH20 (ml/min)

new

Flow RateH20 (ml/h)

new

Flush Volumecurrent

Flush Volumenew

Units(Box/Case)

CurrentItem

Number

FutureItem

Number

24 14 Yellow 17 14 840 0,3 0,4 20/80 383600 383640

24 19 Yellow 17 13 780 0,3 0,4 20/80 383601 383641

22 25 Blue 28 27 1620 0,3 0,4 20/80 383602 383642

20 25 Pink 45 54 3240 0.3 0.5 20/80 383605 383646

20 32 Pink 45 52 3120 0.3 0.5 20/80 383606 383647

20 45 Pink 40 48 2880 0.4 0.5 20/80 383607 383648

18 32 Green 65 84 5040 0.4 0.5 20/80 383608 383649

18 45 Green 60 78 4680 0.4 0.5 20/80 383609 383650

Page 50: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

52 Infusion Therapy

CLOSED IV CATHETERSYSTEM

BD Nexiva™ with BD Connecta™ Q-Syte™ Stopcock Version

Sterile, single use

BD Nexiva™ with BD Connecta™Q-Syte™ Stopcock Version

BD Nexiva™ with Single BD Connecta™ Stopcock Version

BD Nexiva™ with Single BD Connecta™Stopcock Version

Sterile, single use

GaugeCatheter

Lengthmm Colour

Flow RateH20 (ml/min)

current

Flow RateH20 (ml/min)

new

Flow RateH20 (ml/h)

new

Flush Volumecurrent

Flush Volumenew

Units(Box/Case)

CurrentItem

Number

FutureItem

Number

24 14 Yellow 17 16 960 0,5 0,6 20/80 383620 383660

24 19 Yellow 17 15 900 0,5 0,6 20/80 383621 383661

22 25 Blue 28 30 1800 0,6 0,6 20/80 383622 383662

20 25 Pink 45 52 3120 0.6 0.8 20/80 383625 383666

20 32 Pink 45 50 3000 0.6 0.8 20/80 383626 383667

20 45 Pink 40 46 2760 0.6 0.8 20/80 383627 383668

18 32 Green 65 78 4680 0.6 0.8 20/80 383628 383669

18 45 Green 60 74 4440 0.6 0.8 20/80 383629 383670

GaugeCatheter

Lengthmm Colour

Flow RateH20 (ml/min)

current

Flow RateH20 (ml/min)

new

Flow RateH20 (ml/h)

new

Flush Volumecurrent

Flush Volumenew

Units(Box/Case)

CurrentItem

Number

FutureItem

Number

24 14 Yellow 17 16 960 0,5 0,6 20/80 383630 383680

24 19 Yellow 17 15 900 0,5 0,6 20/80 383631 383681

22 25 Blue 28 30 1800 0,6 0,6 20/80 383632 383682

20 25 Pink 45 52 3120 0.6 0.8 20/80 383635 383686

20 32 Pink 45 50 3000 0.6 0.8 20/80 383636 383687

20 45 Pink 40 46 2760 0.6 0.8 20/80 383637 383688

18 32 Green 65 78 4680 0.6 0.8 20/80 383638 383689

18 45 Green 60 74 4440 0.6 0.8 20/80 383639 383690

Next Ge

neration

Next Ge

neration

Page 51: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Infusion Therapy 53

BD Q-Syte™

Sterile, single use

Description Priming Volume Flow Rate Box content Item(ml) (ml/min.) units number

BD Q-Syte™ Stand Alone 0.1 525 50 385100BD Q-Syte™ 15 cm Standard Bore Extension 1.14 445 25 385101BD Q-Syte™ 15 cm Micro Bore Extension 0.21 49 50 385102

Description

BD Q-Syte™ Luer Access Split Septum is a closedneedleless IV access device which helps to reduce the risk ofcatheter related bloodstream infections, accidentalneedlestick injuries and the potential for contamination

Key benefits of BD

� Closed

� Needleless

� Simple - only 2 material components (silicone andpolycarbonate)

FLUID CONNECTORS

Closed Open

The system is designed for

� Use on ISO standard IV medical devices

� Use with intermittent or continnuous infusion

� Connection and disconnection of syringes and IV sets

� Blood withdrawal

� Use on arterial lines

Page 52: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

54 Infusion Therapy

FLUID CONNECTORSBD Connecta™ Stopcock with BD Q-Syte™

Sterile, single use

Description Priming Volume Flow Rate Box content Item(ml) (ml/min.) units number

BD Q-Syte™ Bi-Extension Set 15 cm Macro Bore 1.6 445 50 385161BD Q-Syte™ Tri-Extension Set 15 cm Macro Bore 2.25 445 50 385162BD Q-Syte™ Bi-Extension Set 15 cm Small Bore 0.45 49 50 385163BD Q-Syte™ Tri-Extension Set 15 cm Small Bore 0.8 49 50 385164BD Connecta™ Stopcock with BD Q-Syte™ 0.31 490/390 50 394501BD Q-Syte™ Vial Adapter 0.1 525 25 385108

Features of BD Q-Syte™ Luer Access Split Septum

� Smooth silicone surface- Swabable, easily disinfected- No interstitial space- May help to achieve appropriate disinfection

� Split Septum- Luer activated closed system- Helps prevent micro-organism ingress

� Lipid compatibilitySuitable for parenteral nutrition

� Luer lock and luer slip compatibility

� Straight large fluid path- Allows high flow rates (> 500 ml/min)- No haemolysis increase

� Clear housing- Complete internal visibility- Help to assure flush efficiacy

� Compact light deviceMay help to increase patient comfort due to thesmaller and lighter design.

Sterilisation method� Ethylene oxide

Shelf life� 3 years

� CE marked

� Latex free, DEHP free

Page 53: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Infusion Therapy 55

BD Posiflow™

Sterile, single use

Description Box content Item numberunits

IV Access Valve 50 385300BD Luer-Lok™ Extension Set 50 385301BD Luer-Lok™ Bifurcated Extension Set 50 385303“Y” Extension Set 25 385305Dual “Y” Extension Set 25 385306Microbore “Y” Extension Set 25 385324Vial Adapter 50 385308

Description� BD Posiflow™ is a closed, needleless IV access valve

which helps manage risks for both patients and caregivers.

� The universal, easy to use system automatically helps toimprove IV access.

� The BD Posiflow™ design helps ensure that catheterpatency is maintained after the flush-syringe isdisconnected. This is achieved by an integrated positivepressure mechanism. With the BD Posiflow™ valve, noadded steps need be taken to prevent fluid backflow upthe catheter.

� A comprehensive product line features the BD Posiflow™valve incorporated into a broad array of catheter extensionsets for more efficient IV delivery.

Closed System� The valve automatically closes when the syringe is

disconnected - BD Posiflow™ could be a part of aneffective infection prevention strategy.

BD Posiflow™ dynamics� Helps eliminate back flow of fluid up the catheter through

positive pressure.

Ergonomic design� Allows for easier and more comfortable placement.

Sterilisation method� Ethylene oxide

Shelf life� 3 years

� CE marked

� Latex free

FLUID CONNECTORS

Page 54: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

56 Infusion Therapy

STOPCOCKS forIV THERAPY and PRESSUREMONITORINGBD Connecta™

Sterile, single use

Description Tap Tap Priming Box content Colour coding Pegs Item numberRotation Colour Volume units

BD Connecta™ 360° White 0.22 ml 100 No 394600BD Connecta™ 360° White 0.22 ml 100 Yes 394601BD Connecta™ 360° Blue 0.22 ml 100 No 394602BD Connecta™ 360° Red 0.22 ml 100 No 394605

BD Connecta™ single stopcocks

Description Extension Tubing Port Tap Tap Priming Box content Colour coding Pegs Item numberlength Rotation Colour Volume units

BD Connecta™ 7 cm Yes 360° White 0.8 ml 50 No 394945BD Connecta™ 10 cm No 360° White 0.8 ml 50 No 394995BD Connecta™ 10 cm No 360° Blue 0.8 ml 50 No 394997BD Connecta™ 25 cm Yes 360° White 1.5 ml 20 No 394936BD Connecta™ 25 cm No 360° White 1.5 ml 20 No 394926BD Connecta™ 50 cm No 360° White 2.8 ml 20 No 394951BD Connecta™ 100 cm No 360° White 5.5 ml 20 No 394961BD Connecta™ 100 cm Yes 360° White 5.5 ml 20 No 394971

BD Connecta™ stopcocks with extension

Description Extension Tubing Priming Box content Item numberlength Volume units

BD Connecta™ 25 cm 1.75 ml 50 397251BD Connecta™ 50 cm 3.50 ml 50 397509BD Connecta™ 75 cm 7.00 ml 50 397997BD Connecta™ 100 cm 7.00 ml 50 397590BD Connecta™ 150 cm 10.5 ml 50 397400

BD Connecta™ extension tube

Description Extension Tubing Priming Box content Item numberlength Volume units

BD Connecta™ 150 cm 1.55 ml 50 397611

BD Connecta™ CoEX-Extension Tube

Description: please see next page.

Description Extension Tubing Priming Box content Item numberlength Volume units

BD Connecta™ 15 cm 0.2 ml 50 397201BD Connecta™ 150 cm 1.55 ml 50 397608BD Connecta™ 200 cm 2.10 ml 50 397610BD Connecta™ 250 cm 2.60 ml 50 397612BD Connecta™ 30 cm 0.30 ml 50 397994

BD Connecta™ micro extension tube

Page 55: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Infusion Therapy 57

Description Extension Tubing Tap Tap Priming Box content Colour coding Pegs Item numberlength Rotation Colour Volume units

3-way stopcock 15 cm 360° White 0.3 ml 50 No 3949823-way stopcock 30 cm 360° White 0.45 ml 50 No 394983

BD Connecta™ low volume extension tube (micro bore and DEHP free PVC)

BD Colour Coding Pegs

STOPCOCKS forIV THERAPY and PRESSUREMONITORINGBD Connecta™

Sterile, single use

BD Connecta™ is the result of BD’s continuous search forimprovement and commitment to risk management in IVTherapy. BD Connecta™ offers the possibility to feel whetherthe stopcock is completely open or closed through the on/offsnaps. The new grade of polycarbonate and high standardmoulding technique contribute to improved resistance tocracking.

Description� Flat clean surface.

� Low priming volume (dead space).

� Straight Two-Way Fluid Path.

� Material allows for use of lipids and chemotherapeuticagents.

Material� Polycarbonate, Polyethylene, Polypropylene

Sterilisation method� Beta Irradiation

Shelf life� 3 years

� CE marked

� Latex free

Description Colour Box content Item numberunits

Colour Coding Pegs - non sterile Red 1000 394187Colour Coding Pegs - non sterile Blue 1000 394188

Page 56: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

58 Infusion Therapy

BD CONNECTA™ MULTIFLO™INFUSION MANIFOLDBD Multiflo™

Sterile, single use

Description Box content Item numberunits

3 way ramp with BD Luer-Lok™ plugs 10 394633With 25 cm tubing 10 394638With 50 cm tubing 10 394637With 150 cm tubing 10 394636

Description Box content Item numberunits

5 way ramp with BD Luer-Lok™ plugs 10 394653With 25 cm tubing 10 394658With 50 cm tubing 10 394657With 150 cm tubing 10 394656

How often do you experience difficulties during multipleinfusion management?

Description� BD Multiflo™ offers high flow rates and at the same time

minimal dead space.

� Clear colour coding line identification and BD FloSwitch™on-off indicators minimise infusion line confusion.

� Risk of cracking is diminished through polypropylenehousing.

� BD Multiflo™ with integrated extension tubing adds aneven higher degree of safety by further reducing the risk ofdisconnections, leakage and contamination.

Sterilisation method� Ethylene oxide

Shelf life� 5 years

� CE marked

� Latex free

BD Multiflo™ 3

Description Box content Item numberunits

BD Connecta™ Multiflo™ pole holder (non sterile) 5 394630

BD Connecta™ Multiflo™ pole holder

BD Multiflo™ 5

Page 57: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Infusion Therapy 59

BD First Midcath™

BD Introsyte™

BD First PICC™

Description� BD First PICC™, our Peripherally Inserted Central

Catheter and BD First Midcath™, our mid-line catheter,both using the unique BD Introsyte™ Precision introducer,making catheter insertion smoother and more comfortablefor patients.

� Breakaway design for easy introducer removal.

� Hydrophilic stylet for smoother removal.

� Reverse catheter printing for convenient accuratemeasurements and integrated extension set with comfortdisk.

Sterilisation method� Ethylene oxide

Shelf life� 5 years

� CE marked

� Latex free

BD First PICC™ and BD First Midcath™

Sterile, single use

Description Gauge length Box content Item number Introducerunits Item Number

BD First PICC™ Peripherally Inserted Central Catheter 3Fr. x 65 cm Single Lumen 5 384156 3840304Fr. x 65 cm Single Lumen 5 384157 3840405Fr. x 65 cm Single Lumen 5 384158 3840505Fr. x 65 cm Dual Lumen 5 384159 384050

Description Gauge length Box content Item numberunits

BD Introsyte™ Precision Introducer 3Fr. x 32 cm 10 3840304Fr. x 32 cm 10 3840405Fr. x 32 cm 10 384050

Description Gauge length Box content Item numberunits

BD First Midcath™ Midline Catheter 3Fr. x 20 cm Single Lumen 5 3843314Fr. x 20 cm Single Lumen 5 384341

PERIPHERALLY INSERTEDMIDLINE and CENTRALCATHETERS FOR IV ACCESS

Page 58: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

60 Infusion Therapy

Description Colour Box content Item numberunits

BD Luer-Lok™ Plug White 200 394080BD Combi Plug Male/Female Orange 100 394075BD Rubber membrane BD Luer-Lok™ plug Yellow 100 394074BD Protection cap for Luer syringe Yellow 100 394090

INFUSION SETS

INFUSIONACCESSORIESCaps and Plugs

Description Length Comment Item numberBD R 87 P 180 cm Vented Standard Set 396350BD R 87 Flexinert™ P 180 cm PVC Free 396352BD R 87 RLS 180 cm Back flow valve in BD Luer-Lok™ 396353BD R 87 V 180 cm Back flow valve in Air Channel 396363BD R 87 V / RLS 180 cm Back flow valve in BD Luer-Lok™ and in Air Channel 396373

BD has a range of quality infusion sets which offer amaximum of safety and user comfort

Description� BD R 87 infusion contributes to managing risks within IV

Therapy due to the lockable ventilation and precise rollerclamp. The 15 mm liquid filter in the drip chamber as wellas the BD Luer-Lok™ connector provide additional patientsafety.

� BD R 87 Flexinert™ P infusion sets - the PVC-freealternative.

� BD R 87 RLS infusion sets with backvalve integrated inthe BD Luer-Lok™ offer an effective protection for parallelinfusions.

� BD R 87 V infusion sets with automatic ventilation offeradditional safety when there is risk for moistening the filterresulting in a halted infusion.

This is prevented by an integrated back flow valve in frontof the bacterial tight filter in the air channel.

� In addition we can also offer customized solutions.

Sterilisation method� Ethylene oxide

� CE marked

� Latex free

Page 59: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Infusion Therapy 61

CLOSED, NEEDLELESSIV INFUSION SYSTEMBD Interlink™

Sterile, single use

Description Box content Item numberunits

Injection site 200 303328Bare cannula 100 303376Lever Lock cannula 100 303370Threaded Lock cannula 100 303379Vial Access cannula 100 303377

Description� BD Interlink™, a unique technology which prevents all risk

of needle stick injury as it contains no needles.

� BD Interlink™, a closed system, with four basiccomponents, which permits:

- reliable, practical and clean connection tointravenous access points (closed system);

- bolus drug administration via intravenous accesspoints by means of closed system;

- collection of blood samples by means of closedsystem, without exposure to blood;

� BD Interlink™ prevents risk of needle stick injuries forhospital staff and minimises septic risk for patients.

� System compatible with the administration of lipids.

Materials� Ordinary cannula, cannula with threaded fitting and

protective polypropylene cap. Polyester injection site andsynthetic elastomer membrane.

Sterilisation method� Gamma Irradiation

� CE marked

� Latex free

Page 60: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

62 Infusion Therapy

Sterile, single use

IV DRESSINGBD Veca-C™ ,BD Veca-Fix™

Description� BD Veca-C™ and BD Veca-Fix™ are sterile IV dressing

for optimum fixation of ported and non-ported IV catheters.

� BD Veca-C™ and BD Veca-Fix™ protects the insertionsite and allows the site to breathe.

� The wound pad absorbs exudate at the insertion site,keeping the site dry.

� A comfort pad, to be placed under the wings of the IVcatheter, is included in the pack.

� In addition, BD Veca-C™ has a transparent window ofpolyurethane that allows for visualisation of phlebitis alongthe catheter track.

Sterilisation method� Ethylene oxide

Shelf life� 5 years

� CE marked

� Latex free

Description Box content Item numberunits

BD Veca-C™ 50 392020BD Veca-Fix™ 50 392015

Page 61: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Infusion Therapy 63

Sterile, single use

Description Box content Item numberunits

BD FloPro™ Transfer needle 50 397015BD FloPro™ Withdrawal cannula 50 394181

Description� The BD Flopro™ Withdrawal cannula allows drugs to be

drawn from a vial into a Luer syringe without using needlesprior to injection.

� The BD Flopro™ Transfer needle allows convenient,economic and safe mixing of pharmaceuticals prior toadministration. The two spikes are siliconised for easierpenetration.

Sterilisation method� Ethylene oxide

� Item number 394181: CE marked

� Latex free

BD Flopro™

Page 62: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

AN

AE

STH

ES

IAS

YS

TEM

S

Page 63: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

SPINAL ANAESTHESIABD™ Whitacre Pencil Point Spinal Needles

Sterile, single use

66 Anaesthesia Systems

Description� Side orifice very close to tip to prevent intermediate

positioning in dura mater.

� 45° injection flow angle reduces the possibility of straddlingthe dura.

� Distal tip with high mechanical strength to minimizebending and breaking.

� Full closure of side orifice by means of hub.

� Translucent base with ‘magnifying’ effect for rapidvisualisation of CSF.

� Silicone-free: no side effects.

� Good needle grip and handling.

� Biologically safe: controlled sterilisation.

� Thin wall ensures identical flash-back time with 27G and25G.

� Individually packed in sterile peel-back ‘blister packs’.

� Designed to spread the dural fibres and help reduce theoccurance of post dural puncture headache.

Type of materials� Needle and hub: Special stainless steel

� Base of needle and hub: Polypropylene

� Attachment of needle/hub to base: Insert moulding

� Marking inks on packaging

Sterilisation method� Ethylene oxide

� CE marked

� Latex free

Description Gauge and Length Colour Box content Item number(mm) code units

BD™ Whitacre pencil point 27G x 90 mm (31/2") Grey 25 40205127G x 103 mm (41/16") Grey 25 40511125G x 90 mm (31/2") Blue 25 402050

25G x 103 mm (41/16") Blue 25 40511024G x 90 mm (31/2") Purple 25 40510422G x 90 mm (31/2") Black 25 401995

BD™ Whitacre long length 27G x 119 mm (411/16") long Grey 10 40944325G x 119 mm (411/16") long Blue 10 409442

BD™ Whitacre with integral introducer 27G x 90 mm (31/2") with 22G (11/4") introducer Grey 25 40507527G x 103 mm (41/16") with 22G (11/4") introducer Grey 25 40511325G x 90 mm (31/2") with 20G (11/4") introducer Blue 25 405076

25G x 103 mm (41/16") with 20G (11/4") introducer Blue 25 405112

Description Colour Box content Item numbercode units

Introducer 20G x 32 mm (11/4") for BD™ Whitacre 25G Yellow 25 405260Introducer 22G x 32 mm (11/4") for BD™ Whitacre 27G Black 25 405261

Introducers

Page 64: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

SPINAL ANAESTHESIABD™ Spinal Needles Quincke Type Point

Sterile, single use

67Anaesthesia Systems

Gauge and Length (mm) Colour Box content Item numbercode units

27G x 90 mm (31/2") Grey 25 40525926G x 90 mm (31/2") Brown 25 40525825G x 90 mm (31/2") Orange 25 40525725G x 75 mm (3") Blue 25 40524623G x 90 mm (31/2") Turquoise 25 40524022G x 90 mm (31/2") Black 25 40525622G x 76 mm (3") Black 25 40525522G x 65 mm (21/2") Black 25 40524422G x 38 mm (11/2") Black 25 40525420G x 90 mm (31/2") Yellow 25 40525320G x 76 mm (3") Yellow 25 40525220G x 38 mm (11/2") Yellow 25 40525119G x 90 mm (31/2") Cream 25 40525019G x 76 mm (3") Cream 25 40524918G x 90 mm (31/2") Pink 25 40524818G x 75 mm (3") Pink 25 405247

Description� Fine Quincke bevel (short bevel): high quality penetration.

� High quality steel needle for easy, regular insertion.

� Accurate alignment of needle and stylet: prevents biopsyeffect.

� Translucent hub for clearer visualisation of CSF.

� Silicone-free: no side effects.

� Good needle grip and handling.

� Biologically safe: controlled sterilisation.

� Individually packed in sterile peel-back ‘blister packs’.

Type of materials� Cannula: Special stainless steel

� Hub of needle and base of stylet: Polypropylene

� Attachment of needle/hub to base: Epoxy resin, or needleset into base

� Marking inks on packaging

Sterilisation method� Ethylene oxide

� CE marked

� Latex free

Page 65: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

SPINAL ANAESTHESIA

68 Anaesthesia Systems

Needles for lumbar puncture and spinal anaesthesia use

Description� Fine Quincke bevel (short bevel): high quality penetration.

� High quality steel needle for easy, regular insertion.

� Accurate alignment of needle and stylet: prevents biopsyeffect.

� Translucent hub for clearer visualisation of CSF.

� Silicone free

� Good needle grip and handling.

� Biologically safe: controlled sterilisation.

Type of materials

� Needle and stylet: Special stainless steel

� Hub of needle and base of hub: Polypropylene

� Attachment of needle/hub to base: Epoxy resin, or needleset into base

� Marking inks on packaging

Sterilisation method� Ethylene oxide

� CE marked

� Latex free

Gauge and Length (mm) Colour code Box content Item numberunits

25G x 119 mm (411/16") Blue 10 40523422G x 130 mm (5") Black 10 40514822G x 180 mm (7") Black 10 40514920G x 150 mm (6") Yellow 10 40521118G x 150 mm (6") Intradiscal therapy needle Pink 10 408360

Long length spinal needles

Gauge and Length (mm) Colour code Box content Item numberunits

Needle 29G x 90 mm (31/2") Transparent 25 405068Introducer 22G x 32 mm (11/4") TransparentNeedle 27G x 90 mm (31/2") Grey 25 405069Introducer 22G x 32 mm (11/4") TransparentNeedle 26G x 90 mm (31/2") Brown 25 405065Introducer 20G x 32 mm (11/4") YellowNeedle 25G x 90 mm (31/2") Orange 25 405084Introducer 20G x 32 mm (11/4") Yellow

Spinal needle sets for local anaesthesia

Gauge and Length (mm) Colour code Box content Item numberunits

22G x 32 mm (11/4") for 27G needles Black 25 40526120G x 32 mm (11/4") for 25G needles Yellow 25 405260

Introducers for fine spinal needles

BD™ Spinal Needles Quincke Type Point

Gauge and Length (mm) Colour code Box content Item numberunits

25G x 25 mm (1") Blue 25 40524325G x 50 mm (2") Blue 25 405245

Paediatric spinal needles

Sterile, single use

Page 66: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

EPIDURAL PRODUCTSBD Perisafe™ Plus, BD Mini-Perisafe™ Plus

Sterile, single use

Anaesthesia Systems 69

Set content Box content Item number Item numberunits with glass syringe with plastic syringe

BD™ Tuohy Weiss epidural needle (with wings) 17G x 80 mmClosed end epidural catheter 19G x 900 mm (36") with introducer0.22µ flat filter 12 401500 401506BD Luer-Lok™ capCatheter connector10 ml low-friction glass or plastic syringeBD™ Tuohy Weiss epidural needle (with wings) 17G x 80 mmOpen end epidural catheter 19G x 900 mm (36") with introducer 12 401700 401507Sets include other accessories as in set numbers 401500 and 401506BD™ Tuohy Weiss epidural needle (with wings) 18G x 80 mmClosed end epidural catheter 20G x 900 mm (36") with introducer 12 401600 401508Sets include other accessories as in set numbers 401500 and 401506BD™ Tuohy Weiss epidural needle (with wings) 18G x 80 mmClosed end epidural catheter 20G x 900 mm (36") with introducer 12 401800 401509Sets include other accessories as in set numbers 401500 and 401506

BD Perisafe™ Plus

Set content Box content Itemunits number

BD™ Tuohy Weiss epidural needle 17G x 80 mmClosed end epidural catheter 19G x 36"- 90 mm with introducerCatheter connector 12 4015100.22µ flat filterBD Luer-Lok™ capBD™ Tuohy Weiss epidural needle 18G x 80 mmClosed end epidural catheter 20G x 36"- 90 mm with introducer 12 401511Other accessories like item number 401510

BD Mini-Perisafe™ Plus (without BD Epilor™ syringe)

Description� Precise adjustment of stylet in the Epidural BD™ Tuohy

Weiss needle, minimising the ‘hole-punch’ effect andpreventing dispersion of tissues as needle moves.

� Light, translucent base with excellent grip facilitatesaccurate placing of the needle in the epidural space.

� Graduated in cm with correspondence between needleand catheter facilitating evaluation of insertion depth.

� The design of the epidural catheter provides increasedstrength, higher flow rate and improves insertion.

� The material of the catheter causes less damage to thedura mater.

Safety of insertion� Radiopaque catheter for increased safety.

� Non-traumatic rounded catheter tip prevents vessel andtissue damage, thus reducing epidural anaesthesia risks.

.� Low strength glass or plastic BD Epilor™ syringe for easy

detection of the epidural space.

� The latex free ‘Catheter Connector’ is designed to holdthe catheter firmly without causing either deformation orkinking.

Packaging� Packed individually in strong peel-back ‘blister packs’

Sterilisation method� Ethylene oxide

Type of materials� The epidural catheter is composed of nylon and tungsten

� CE marked

� Latex free

Page 67: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

70 Anaesthesia Systems

EPIDURAL PRODUCTSBD Perisafe™

Sterile, single use

Description� Secondary bevel point geometry in BD™ Tuohy needles is

specially designed to provide more tactile feedback duringprocedure.

� Shorter point length than standard epidural needlesdesigned to further minimize accidental dural puncture.

� Precise adjustment of stylet in the Epidural Weiss needle,minimises the ‘hole-punch’ effect and hence disruption oftissues as the needle moves

� Low friction L.O.R.* syringe for easy detection of theepidural space

Standard Components included in all BD Perisafe™Kits:� BD™ Tuohy Weiss epidural needle (90mm / 3.5’’)

� Catheter connector

� Round epidural catheter with

� BD™ Tuohy borst adaptor

Sterilisation method� Ethylene oxide

Type of materials� The epidural catheter is composed of nylon and tungsten

� CE marked

� Latex free

3.5’’ BD™ Tuohy Weiss Plastik L.O.R.* Closed end Open end Filter BD Luer-Lok™ Box content Itemepidural needle Syringe epidural catheter epidural catheter Cap units number

16G x 19G x x 12 40205618G 20G 12 40206218G x 20G x x 12 40206117G x 19G x 12 40206017G x 19G 12 40205916G x 19G x x 12 40205816G x 19G x 12 40205716G 19G 12 40205518G x 20G x x 12 40206417G x 19G x x 12 40206618G x 19 G x x 12 40206717G x 19 G x x 12 402065

BD Perisafe™ - Set content

* Loss of Resistance Syringe

Page 68: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Anaesthesia Systems 71

BD Epidural Products - Individual Components

Sterile, single use

EPIDURAL PRODUCTS

Description

Catheter� Eases threadability and placement

� Does not interfere with flow

� Flexible thus reduces potential for dural puncture

� Available in closed end (multiport) tip configuration

� Catheter with depth markings to match needle length

� Latex free

Connector� Prevent catheter pull-out while resisting occlusion from

overtightening.

� Latex free

BD Epilor™ Loss of Resistance Syringe� Epilor Plastic Loss of Resistance (L.O.R.) syringe has a

double ribbed stopper to prevent leakage duringaspiration.

� Epilor Precision Glass Loss of Resistance (L.O.R.) syringehas a smooth plunger movement to help locate theepidural space.

Individual components Box content Item numberunits

7ml BD Luer-Lok™, Plastic L.O.R.* Syringe 10 4052917ml Luer Slip, Plastic L.O.R.* Syringe 10 40529219G epidural catheter - closed end with 8 cm epidural connector 10 40051320G epidural catheter - closed end with 8 cm epidural connector 10 400511Epidural filter 0.22µ with BD Luer-Lok™ cap 5 401490Statlock Securement Device 50 402076

Page 69: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

COMBINED SPINAL/EPIDURALANAESTHESIA SETSBD Durasafe Plus™

Sterile, single use

72 Anaesthesia Systems

BD Durasafe™ Sets for Combined Spinal/Epidural (CSE)Anaesthesia

Description� The BD range of CSE anaesthesia sets has been

designed to ensure correct placing of the needle. Thelength of the spinal needle has been calculated to extend11 mm further than the Epidural Weiss needle.

� All BD Durasafe™ sets contain the low strength glass orplastic BD Epilor™ syringe and the latex-free ‘CatheterConnector’, enhancing the reliability of the connectionbetween the catheter and the 0.22 micron filter.

� The design of the epidural catheter provides increasedstrength, higher flow rate and improved insertion.

� The material of the catheter causes less damage to thedura mater.

Epidural Set components� Certain components are also available separately.

Please contact your local BD office for further information.

Sterilisation method� Ethylene oxide

Packaging� Packed individually in strong peel-back ‘blister packs’

Type of materials� The epidural catheter is composed of nylon and tungsten

� CE marked

� Latex free

Set content Box content Item number Item numberunits with glass syringe with plastic syringe

BD™ Tuohy Weiss epidural needle (with wings) 17G x 80 mmBD™ Whitacre pencil point needle 25G x 110 mmClosed end epidural catheter 19G x 900 mm (36") with introducer0.22µ flat filter 12 405090 401504BD Luer-Lok™ capCatheter connector10 ml low-friction glass or plastic syringe

Page 70: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Sterile, single use

Anaesthesia Systems 73

Description� Light pressure on the push-button enables accurate

placing and adjustment of the BD™ Whitacre needle in thesubarachnoid space.

� The epidural needle, connected to the spinal needle, islocked into position as required.

� 0 to 15 mm adjustment at 1mm intervals to comply withappropriate techniques and the variations in patientmorphology.

� All adjustable BD Durasafe™ sets contain the new lowstrength glass or plastic BD Epilor™ syringe and the newlatex-free ‘Catheter Connector’, enhancing the reliabilityof the connection between the catheter and the 0.22micron filter.

� The design of the epidural catheter provides increasedstrength, higher flow rate and improved insertion.

� The material of the catheter causes less damage to thedura mater.

Sterilisation method� Ethylene oxide

Type of materials� The epidural catheter is composed of nylon and tungsten

� CE marked

� Latex free

Set content Box content Item number Item numberunits with glass syringe with plastic syringe

BD™ Tuohy Weiss epidural needle (with wings) 17G x 80 mmBD™ Whitacre pencil point needle 27G x 143 mmClosed end epidural catheter 19G x 900 mm (36") with introducer10 ml low-friction glass or plastic syringe 12 405056 4015010.22µ flat filterBD Luer-Lok™ capCatheter connectorBD™ Tuohy Weiss epidural needle (with wings) 18G x 80 mmBD™ Whitacre pencil point needle 27G x 143 mmClosed end epidural catheter 20G x 900 mm (36") with introducer10 ml low-friction glass or plastic syringe 12 405057 4015020.22µ flat filterBD Luer-Lok™ capCatheter connector

Adjustable BD Durasafe Plus™

COMBINED SPINAL/EPIDURALANAESTHESIA SETS

Page 71: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

BD Durasafe Plus™

Sterile, single use

74 Anaesthesia Systems

COMBINED SPINAL/EPIDURALANAESTHESIA SETS

Description Lock CSE Kits� The CSE lock mechanism can be de-activated and the

BD™ Whitacre needle re-positioned for regionalanaesthetic delivery.

� The CSE lock mechanism allows the connection of asyringe and injection of local anaesthetic withoutdisplacement of the spinal needle tip.

� The secure locking device permits the spinal needle tolock at any extension from 0 - 15mm distal to the epiduraltip.

� The Whitacre™ spinal needle can rotate 360° when themechanism is locked.

� The locking device is easy to use and provides stabilitybetween the two procedural needles putting you in control.

Sterilisation method� Ethylene oxide

Type of materials� The epidural catheter is composed of nylon and tungsten

� CE marked

� Latex free

Set content Box content Item numberunits

BD™ Tuohy Weiss epidural needle with CSE lock 17G x 90 mmBD™ Whitacre pencil point needle 27G x 143 mmClosed end epidural catheter and introducer 19G x 900 mm (36")7 ml LOR plastic syringe 6 4002860.22µ flat filterBD Luer-Lok™ capCatheter connectorBD™ Tuohy Weiss epidural needle with CSE lock 18G x 90 mmBD™ Whitacre pencil point needle 27G x 143 mmClosed end epidural catheter and introducer 20G x 900 mm (36")7 ml LOR plastic syringe 6 4002870.22µ flat filterBD Luer-Lok™ capCatheter connector

Page 72: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Anaesthesia Systems 75

Gauge and Length Colour code Box content Item numberunits

16G x 90 mm (31/2") modified point Clear 10 40519417G x 90 mm (31/2") modified point Grey 10 40519117G x 127 mm (5") modified point Grey 10 40519318G x 90 mm (31/2") modified point Pink 10 40518818G x 127 mm (5") modified point Pink 10 40519020G x 51 mm (2") modified point Yellow 10 40518520G x 90 mm (31/2") modified point Yellow 10 405186

Gauge and Length Colour code Box content Item numberunits

17G x 90 mm (31/2") modified point Grey 10 40509218G x 90 mm (31/2") modified point Pink 10 40501820G x 90 mm (31/2") modified point Yellow 10 405028

BD™ Tuohy or BD™ Tuohy Weiss Epidural needles

Description� Epidural needle with locking base and ‘modified Huber’

bevel to minimise accidental dural puncture.

� Needle graduated every 10 mm, except paediatric epiduralneedle which is graduated every 5 mm.

� Needle equipped with moulded plastic hub.

BD™ Regional Block Needle

Description� Short-bevel 22G needle with a marker ball 38 mm from the

distal end.

Packaging� Packed individually in strong peel-back ‘blister packs’

Sterilisation method� Ethylene oxide

� CE marked

� Latex free

BD™ Tuohy Epidural needle

BD™ Tuohy Weiss Epidural needle

Gauge and Length Colour code Box content Item numberunits

22G x 38 mm (11/2") Black 10 408348

BD™ Regional Block Needle (RBN)

LOCAL/REGIONALANAESTHESIA NEEDLES

Sterile, single use

Page 73: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

76 Anaesthesia Systems

Gauge and Length Colour code Box content Item numberunits

22G x 153 mm (6") Black 10 40826822G x 203 mm (8") Black 10 408269

Description� 22G (7/10 mm) thin wall, short bevel (26°) needle with

accurate grip which reduces the risk of vessel and tissuedamage. Translucent base aids visualisation of vascularbreaks.

� Hub locking system to prevent biopsy hazards.

� Two different needle lengths available.

� Needle graduated in centimetres to measure insertiondepth.

Indications� Soft tissue biopsy.

� Transhepatic cholangiography.

� Chemonucleolysis: the intradiscal needle is used as aguide for the BD™ Chiba needle the distal end of whichhas a 2 cm curve to improve intradiscal insertion.

Anaesthesiology� Sciatic block.

Packaging� Packed individually in peel-back ‘blister packs’

Sterilisation method� Ethylene oxide.

� CE marked

� Latex free

BD™ Chiba Needles

INTRADISCAL NEEDLES

Page 74: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

77Anaesthesia Systems

BIOPSY NEEDLES

Sterile, single use

Gauge and Length Colour code Box content Item numberunits

20G x 89 mm (31/2") Yellow 10 40826220G x 140 mm (51/2") Yellow 10 40826320G x 178 mm (7") Yellow 10 40826422G x 89 mm (31/2") Black 10 40826522G x 140 mm (51/2") Black 10 40826622G x 178 mm (7") Black 10 408267

BD™ Westcott Biopsy needle (for histological, cytological and bacteriological sampling)

Gauge and Length Colour code Box content Item numberunits

11G x 102 mm (4") White 10 408627

BD™ Biopsy needle for bone marrow biopsy

BD™ Biopsy needle for bone marrow biopsy

Description� High quality collection due to double bevel with cutting

edge.

� Single sterile use ensures quality and safety.

� Knob at end of bevel facilitates collection procedure.

� Winged to allow excellent handling.

� Biopsy of bone marrow, at iliac crest level.

BD™ Westcott Biopsy needle

Description� For direct percutaneous fine needle aspiration biopsy.

� Available in two gauges and three lengths for maximumversatility for both deep and superficial masses.

� This needle has proven use for many biopsy applicationsincluding that of pulmonary, hilar and mediastinal masses,as well as lesions in the liver, pancreas and other areas.

� The BD™ Westcott Biopsy needle is a 2-piece, thin-wallneedle modified to include a slotted opening measuring2.2 mm in length located approximately 3 mm from theneedle tip.

� The slot creates a second cutting edge, in addition to theneedlepoint, enabling aspirations of larger amounts ofmaterial without any apparent increase in complications.

� For histological, cytological and bacteriological sampling.

Packaging� Packed individually in peel-back ‘blister packs’

Sterilisation method� Ethylene oxide

� CE marked

� Latex free

Page 75: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

SUPRAPUBICCATHETER

Sterile, single use

78 Anaesthesia Systems

BD Bonnano™

Dimension Box content Item numberunits

14G x 30 cm (11") preformed catheter (7FR) with 18G x 30 cm (11") introducing needle 6 408289

The BD Bonnano™ catheter is a vesical catheter forsuprapubic urinary bladder drainage, designed to reduceurinary infections. Vesical re-education is not systematicallyrequired and patient autonomy can be verified withoutremoving the catheter.

Description� High quality BD needle ensure non-traumatic introduction.

� Efficient drainage: Pre-formed curved catheter tip preventsobstruction by vesical wall and prevents trauma. The 3lateral orifices and the distal orifice provide a flow rate of10 ml/min.

� Wide wings ensure very efficient attachment.

� Clamp fitted onto drainage tube ensures flexible use.

Contents of Kit� Pre-formed “corkscrew” FEP Polymer catheter.

� Introducer needle, 30 cm long, diameter 12/10, with airpermeable cap.

� Rubber tubing with BD Luer-Lok™ connector and clampfor attachment of urine bag and discontinuation ofdrainage.

Sterilisation method� Ethylene oxide

� CE marked

� Latex free

Page 76: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

ARTERIAL ANGIOGRAPHYNEEDLES

Sterile, single use

Anaesthesia Systems 79

Description Gauge Colour code Box content Itemunits number

BD Amplatz™ catheter needle foruse with guidewire with a 18G x 64 mm (21/2") Pink 10 408275diameter of 80/100 to 95/100(0.032" and 0.038")

BD Amplatz™ Needle

Description Gauge Colour code Box content Itemunits number

For usage with guidewires witha diameter between 80/100 and 18G x 50 mm (23/64") Pink 10 40827095/100 ( 0.032" and 0.038")

BD™ Potts-Cournand Needle for .035" and .038" wires

Description Gauge Colour code Box content Itemunits number

For usage with guidewires witha diameter between 80/100 and 18G x 73 mm (27/8") Pink 10 40827395/100 ( 0.032" and 0.038")

BD™ Arterial Needle

BD has designed three needles for use by radiologists toimprove arterial insertion before angiography.

BD Amplatz™ Needle

Description� In three parts, with an FEP Polymer * catheter, an inner

needle and a fitted hub. The FEP Polymer radiopaquecatheter fits over the needle perfectly and is bevelled toensure penetration without trauma. Extremely flexible inorder to facilitate the insertion of a guidewire.

BD™ Potts-Cournand Needle

Description� In three parts consisting of an outer cannula, an inner

cannula and a cap. For fast, efficient identification ofarterial flow.

BD™ Arterial Needle

Description� Single sterile use, in two parts, designed for Seldinger

technique

� Inner needle

� Short-bevel arterial

� Thin wall outer needle

� Bevelled tip for easy insertion

� Polished tapered tip facilitates insertion of guidewire insidethe needle

� Winged base improves handling

Packaging� Packed in individual strong peel-back ‘blister packs’.

Sterilisation method� Ethylene oxide

� CE marked

� Latex free

* Teflon® is a registered trademark of DuPont

Page 77: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

CR

ITIC

AL

CA

RE

Page 78: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

82 Critical Care and Haemodynamic Monitoring

BD Floswitch™

Sterile, single use

Description Box contents Item numberunits [No for PL, CZ, HU, SK]

BD Floswitch™ 25 681033 [681746]

Description� BD Floswitch™ acts as an ON/OFF device on infusion

lines, stopping the flow in order to carry out lineprocedures in closed circuit. Reduces the risk of patientemboli and potential contamination of hospital staff byexposure to blood. BD Floswitch™ therefore considerablyincreases safety.

BD Floswitch™ closed

� System patented. External compression of the extensiontubing by means of a steel ball, provides risk-freeunambiguous opening and closing of the infusion line.

BD Floswitch™ open

� BD Floswitch™ can be connected to any catheter fittedwith a Luer connector. Winged to facilitate attachment.

Sterilisation method� Ethylene oxide

Shelf life� 5 years

Class IIa according to European Medical Devices Directive93/42/EEC.

Page 79: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Critical Care and Haemodynamic Monitoring

CENTRAL VENOUS CATHETERSBD Secalon-T™

Sterile, single use

Description� BD Secalon-T™ emergency catheter designed for high

flow rate infusions.

� Incorporating a BD Floswitch™, BD Secalon-T™ is idealfor rapid short-term insertion into central veins or largeperipheral vessels.

� Complete kit contains pre-puncture stylus and stabilisingwing.

Sterilisation method� Ethylene oxide

Shelf life� 5 years

Class III according to European Medical Devices Directive93/42/EEC.

Gauge Length Catheter ext. Colour Box content Item numberCatheter mm diameter mm units [No for PL, CZ, HU, SK]18G 90 1.2 Green 25 681000 [681740]16G 130 1.7 Grey 25 681002 [681741]16G 160 1.7 Grey 25 681004 [681742]14G 160 2.0 Orange 25 681006 [681743]

83

Page 80: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

84 Critical Care and Haemodynamic Monitoring

CENTRAL VENOUS CATHETERSBD Secalon™ Seldy

Sterile, single use

Description� BD Secalon™ Seldy - a “Seldinger” central venous

catheter made of polyurethane and fitted with a BDFloswitch™.

� 681011 contain a cannula type and needle type introducerwith a soft-tip “straight” metal guidewire.

Sterilisation method:� Ethylene oxide

Shelf life:� 5 years

Class III according to European Medical Devices Directive93/42/EEC 93/42/EEC.

Gauge Length Cannula Introducer Needle Introducer Guidewire OD & Length Box content Item numberCatheter mm mm mm mm units16G 200 16G x 60 17G x 70 0.9 x 450 10 68101416G 420 16G x 60 17G x 70 0.9 x 650 10 681011

Page 81: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Critical Care and Haemodynamic Monitoring 85

BD Careflow™ is a range of paediatric and adultpolyurethane central venous catheters designed forcatheterisation by the Seldinger technique.

Available in single, double, triple, quadruple and quint lumenformats, this range of sets contains a steel guidewire and theBD Venaguide™ Seldinger wire advancing device facilitatingsingle handed guidewire insertion.

BD Careflow™ catheters are latex free with taperedatraumatic catheter tip reducing the risk of venous damageand improving catheter insertion.

The streamlined junction hub enables ease of catheter sutureand comfortable positioning on the patients skin.

BD Careflow™ catheters offer 1cm and 5cm interval depthmarkings to facilitate catheter placement with clear lumensize and hub colour coding indication.

BD Floswitch™ and BD Floswitch™ introducer catheteroptions available throughout range.

CENTRAL VENOUS CATHETERSBD Careflow™ Single Lumen

Sterile, single use

Catheter Catheter Cannula BD Floswitch™ Needle Guidewire Box Flow Rate Item No. Item No.External Length Introducer Introducer Introducer OD & content (ml/min) w/o withDiameter (mm) Gauge Length (mm) Gauge Length (mm) Gauge Length (mm) Length (mm) units D BD Floswitch™ BD Floswitch™

[No. for PL, CZ,HU, SK]

2.5Fr (22G) 100 N/A N/A 20G 45 22G 40 0.5 x 350 10 10 681614 6816233Fr (20G) 150 N/A N/A 20G 45 20G 40 0.5 x 350 10 16 681639 681640

[681749]3Fr (20G) 200 N/A N/A 20G 45 20G 40 0.5 x 450 10 15 681643 6816444Fr (18G) 200 N/A N/A 18G 60 17G 70 0.6 x 450 10 36 681649 6816505Fr (16G) 150 N/A N/A 15G 70 17G 70 0.9 x 450 10 71 681669 6816705Fr (16G) 200 N/A N/A 15G 70 17G 70 0.9 x 450 10 63 681672 6816737Fr (14G) 150 N/A N/A 14G 70 17G 70 0.9 x 450 10 190 681706 6817077Fr (14G) 200 N/A N/A 14G 70 17G 70 0.9 x 450 10 136 681709 681710

BD Careflow™ Single Lumen Sets without Extension

Description� Single lumen BD Careflow™ with BD Floswitch™ set

contents: BD Careflow™ polyurethane catheter, steelneedle introducer, BD Floswitch™ overneedle introducer,vessel dilator, BD Venaguide™ Seldinger wire advancingdevice, BD Floswitch™ revolving BD Luer-Lok™ system,Luer Lock plug and secondary fixation device.

� Single lumen BD Careflow™ without BD Floswitch™ setcontents: BD Careflow™ polyurethane catheter, steelneedle introducer, BD Venaguide™ Seldinger wireadvancing device and secondary fixation device.

Sterilisation method� Ethylene oxide

Shelf life� 5 years

Class III according to European Medical Devices Directive93/42/EEC.

Page 82: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Critical Care and Haemodynamic Monitoring86

CENTRAL VENOUS CATHETERSBD Careflow™ Single Lumen Catheter Sets

Sterile, single use

Catheter Catheter Cannula BD Floswitch™ Needle Guidewire Box Flow Rate Item Number Item NumberExternal Length Introducer Introducer Introducer OD & content (ml/min) w/o withDiameter (mm) Gauge Length (mm) Gauge Length (mm) Gauge Length (mm) Length (mm) units D BD Floswitch™ BD Floswitch™

[No. for PL, CZ, [No. for PL, CZ,HU, SK] HU, SK]

2.5Fr (22G) 60 22G 38 N/A N/A 22G 40 0.5 x 350 5 12 6816122.5Fr (22G) 100 22G 38 N/A N/A 22G 40 0.5 x 350 5 10 6816222.5Fr (22G) 200 22G 38 N/A N/A 22G 40 0.5 x 650 5 7 6816343Fr (20G) 150 20G 45 N/A N/A 22G 40 0.5 x 450 5 18 6816473Fr (20G) 200 20G 45 N/A N/A 22G 40 0.5 x 650 5 15 6816384Fr (18G) 60 20G 45 N/A N/A 20G 40 0.5 x 350 5 47 6816244Fr (18G) 200 20G 45 N/A N/A 20G 40 0.5 x 650 5 35 6816585Fr (16G) 150 16G 70 N/A N/A 17G 70 0.9 x 450 5 65 6816625Fr (16G) 200 16G 70 N/A N/A 17G 70 0.9 x 700 5 60 681666

[681753]5Fr (16G) 300 16G 70 N/A N/A 17G 70 0.9 x 700 5 46 6816797Fr (14G) 150 16G 70 N/A N/A 17G 70 0.9 x 450 5 159 6816987Fr (14G) 200 16G 70 N/A N/A 17G 70 0.9 x 700 5 149 6816997Fr (14G) 300 16G 70 N/A N/A 17G 70 0.9 x 700 5 136 681701

1. BD Careflow™ Single Lumen Sets with extension

2.5Fr (22G) 200 N/A N/A 20G 45 22G 40 0.5 x 450 10 7 681633[681760]

2. BD Careflow™ Single Lumen Midline with BD Floswitch™

5Fr (16G) 150 16G 70 N/A N/A 17G 70 0.9 x 450 10 65 6816605Fr (16G) 200 16G 70 N/A N/A 17G 70 0.9 x 700 10 60 6816645Fr (16G) 300 16G 70 N/A N/A 17G 70 0.9 x 700 10 46 681678

3. BD Careflow™ Single Lumen Midline with integral BD Floswitch™

2.5Fr (22G) 60 N/A N/A 20G 45 22G 40 0.5 x 350 5 12 681615[681748]

4Fr (18G) 60 N/A N/A 20G 45 20G 40 0.5 x 350 5 47 681625

4. BD Careflow™ Single Lumen Midline with extension and BD Floswitch™

1. Single lumen BD Careflow™ set with extension contents*†:BD Careflow™ polyurethane catheter with clearextension, extension slide clamp, cannula introducer, steel needle,introducer, vessel dilator, BD Venaguide™ Seldinger wireadvancing device, BD Luer-Lok™ plug, secondary fixation deviceand 5ml syringe.

2. Single lumen BD Careflow™ Midline set with BD Floswitch™contents*: BD Careflow™ polyurethane catheter with clearextension, steel needle introducer, BD Floswitch™ overneedleintroducer, PTFE coated soft-tip straight guidewire,BD Floswitch™ revolving BD Luer-Lok™ system, Luer Lock plugand secondary fixation device.

3. Single lumen BD Careflow™ set with integral BD Floswitch™contents*: BD Careflow™ polyurethane catheter with clearextension and integral BD Floswitch™, cannula introducer,

steel needle introducer, vessel dilator, BD Venaguide™ Seldingerwire advancing device, BD Luer-Lok™ plug and secondaryfixation device.

4. Single lumen BD Careflow™ set with extension andBD Floswitch™ contents*†: BD Careflow™ polyurethane catheterwith clear extension, steel needle introducer, BD Floswitch™overneedle introducer, vessel dilator, BD Venaguide™ Seldingerwire advancing device, BD Floswitch™ revolving BD Luer-Lok™system, Luer Lock plug and secondary fixation device.

* Sterilisation method: Ethylene oxide

Shelf life: 5 years(except 681660, 681664 and 681678 with shelf life: 3 years )

Class III according to European Medical Devices Directive93/42/EEC.Sterile double tray packaging for increased safety

1

3 4

2

Page 83: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

BD Careflow™ Double Lumen Sets

Critical Care and Haemodynamic Monitoring 87

CENTRAL VENOUS CATHETERSBD Careflow™ Double Lumen Catheter Sets

Sterile, single use

4Fr (20G, 22G) 60 20G 45 20G 45 20G 40 0.5 x 350 5 20 8 681616 6816174Fr (20G, 22G) 100 20G 45 20G 45 20G 40 0.5 x 350 5 19 6 681626 6816274Fr (20G, 22G) 150 20G 45 20G 45 20G 40 0.5 x 450 5 16 4 681653 6816524Fr (20G, 22G) 200 20G 45 20G 45 20G 40 0.5 x 450 5 17 4 681656 681655

[681752]5Fr (18G, 20G) 60 18G 60 18G 60 17G 70 0.6 x 650 5 40 10 681619 6816285Fr (18G, 20G) 150 18G 60 18G 60 17G 70 0.5 x 350 5 29 6 681683 6816825Fr (18G, 20G) 200 18G 60 18G 60 17G 70 0.5 x 650 5 30 6 681687 6816867Fr (16G, 18G) 150 16G 70 15G 70 17G 70 0.9 x 450 5 74 24 681703 681702

[681755] [681754]7Fr (16G, 18G) 200 16G 70 15G 70 17G 70 0.9 x 700 5 73 21 681714 6817137Fr (16G, 18G) 300 16G 70 15G 70 17G 70 0.9 x 700 5 61 19 681718 681717

[681756]

Description� Double lumen BD Careflow™ with BD Floswitch™ set

contents: BD Careflow™ double lumen polyurethanecatheter with clear extensions, steel needle introducer,BD Floswitch™ overneedle introducer, vessel dilator,BD Venaguide™ Seldinger wire advancing device,BD Floswitch™ revolving BD Luer-Lok™ system, LuerLock plugs and secondary fixation device. Sterile doubletray packaging for increased safety.

� Double lumen BD Careflow™ without BD Floswitch™ setcontents: BD Careflow™ double lumen polyurethanecatheter with clear extensions, cannula introducer, steelneedle introducer, BD Venaguide™ Seldinger wireadvancing device, extension slide clamps, 5ml syringe,Luer Lock plugs and secondary fixation device.Sterile double tray packaging for increased safety.

Sterilisation method� Ethylene oxide

Shelf life� 5 years

Class III according to European Medical Devices Directive93/42/EEC.

Catheter Catheter Cannula BD Floswitch™ Needle Guidewire Box Flow Rate Item No. Item No.External Length Introducer Introducer Introducer OD & content (ml/min) w/o withDiameter (mm) Gauge Length (mm) Gauge Length (mm) Gauge Length Length (units) D M1 M2 P1 P2 BD Floswitch™ BD Floswitch™

(mm) (mm) [No. for PL, CZ, [No. for PL, CZ,HU, SK] HU, SK]

Page 84: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Critical Care and Haemodynamic Monitoring88

CENTRAL VENOUS CATHETERS

Sterile, single use

BD Careflow™ Triple Lumen Sets

Catheter Catheter Cannula BD FloswitchTM Needle Guidewire Box Flow rate Code CodeExternal Length Introducer Introducer Introducer OD & Length content (ml/min) w/o withDiameter Gauge Length Gauge Length Gauge Length Length units D M1 M2 P1 P2 BD FloswitchTM BD FloswitchTM

(mm) (mm) (mm) (mm) [No. for PL, CZ, [No. for PL, CZ,HU, SK] HU, SK]

5Fr (18G, 20G, 20G) 60 18G 60 18G 60 17G 40 0.6 x 450 5/50 40 10 12 681620 6816295Fr (18G, 20G, 20G) 100 18G 60 18G 60 17G 40 0.6 x 450 5/50 32 7 8 681630 6816185Fr (18G, 20G, 20G) 150 18G 60 18G 60 17G 40 0.6 x 450 5/50 29 5 6 681691 6816905Fr (18G, 20G, 20G) 200 18G 60 18G 60 17G 40 0.6 x 450 5/50 26 5 5 681695 6816947Fr (16G, 18G, 18G) 150 16G 70 15G 70 17G 70 0.9 x 450 5/50 66 22 23 681721 681720

[681757]7Fr (16G, 18G, 18G) 200 16G 70 15G 70 17G 70 0.9 x 700 5/50 59 16 17 681725 681724

[681759] [681758]7Fr (16G, 18G, 18G) 300 16G 70 15G 70 17G 70 0.9 x 700 5/50 53 11 9 681729 681728

Description� Triple lumen BD Careflow™ with BD Floswitch™ set

contents: BD Careflow™ triple lumen polyurethanecatheter with clear extensions, steel needle introducer,BD Floswitch™ overneedle introducer, vessel dilator,BD Venaguide™ Seldinger wire advancing device,BD Floswitch™ revolving BD Luer-Lok™ system, LuerLock plugs and secondary fixation device.Sterile double tray packaging for increased safety.

� Triple lumen BD Careflow™ without BD Floswitch™ setcontents: BD Careflow™ triple lumen polyurethanecatheter with clear extensions, cannula introducer, steelneedle introducer, BD Venaguide™ Seldinger wireadvancing device, extension slide clamps, 5ml syringe,Luer Lock plugs and secondary fixation device.Sterile double tray packaging for increased safety.

Sterilisation method� Ethylene oxide

Shelf life� 5 years

Class III according to European Medical Devices Directive93/42/EEC.

BD Careflow™ Triple Lumen Catheter Sets

Page 85: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Critical Care and Haemodynamic Monitoring 89

CENTRAL VENOUS CATHETERSBD Careflow™ Quad Lumen Catheter Sets

Sterile, single use

8.5Fr (14G,16G,16G,18G) 150 16G 70 15G 70 17G 70 0.9 x 450 5 64 82 57 20 681731 6817328.5Fr (14G,16G,16G,18G) 200 16G 70 15G 70 17G 70 0.9 x 700 5 58 76 45 19 681733 681734

Description� Quad lumen BD Careflow™ with BD Floswitch™ set

contents: BD Careflow™ quad lumen polyurethanecatheter with clear extensions, steel needle introducer,BD Floswitch™ overneedle introducer, vessel dilator,

BD Venaguide™ Seldinger wire advancing device,BD Floswitch™ revolving BD Luer-Lok™ system, scalpel,Luer Lock plugs and secondary fixation device.Sterile double tray packaging for increased safety.

� Quad lumen BD Careflow™ without BD Floswitch™ setcontents: BD Careflow™ quad lumen polyurethanecatheter with clear extensions, cannula introducer, steelneedle introducer, BD Venaguide™ Seldinger wireadvancing device, extension slide clamps, 5ml syringe,scalpel, Luer Lock plugs and secondary fixation device.Sterile double tray packaging for increased safety.

Sterilisation method� Ethylene oxide

Shelf life� 5 years

Class III according to European Medical Devices Directive93/42/EEC.

BD Careflow™ Quad Lumen Sets

Catheter Cath. Cannula BD FloswitchTM Needle Guidewire Box Flow rate Code CodeExternal Length Introducer Introducer Introducer OD & Length content (ml/min) w/o withDiameter Gauge Length Gauge Length Gauge Length units D M1 M2 P1 P2 BD FloswitchTM BD FloswitchTM

Page 86: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Critical Care and Haemodynamic Monitoring90

CENTRAL VENOUS CATHETERS

Sterile, single use

BD Careflow™ Quint Lumen Catheter Sets

Catheter Cath. Cannula BD Floswitch™ Needle Guidewire Box Flow Rate Code CodeExternal Length Introducer Introducer Introducer OD & content (ml/min) w/o withDiameter Gauge Length Gauge Length Gauge Length Length units D M1 M2 P1 P2 BD Floswitch™ BD Floswitch™

(mm) (mm) (mm) (mm) (mm)

BD Careflow™ Quint Lumen Sets9.5Fr (14G,16G,16G,18G,18G) 150 16G 70 15G 70 17G 70 0.9 x 450 5 73 61 65 19 21 681735 6817369.5Fr (14G,16G,16G,18G,18G) 200 16G 70 15G 70 17G 70 0.9 x 700 5 68 58 60 13 12 681737 681738

Description� Quint lumen BD Careflow™ with BD Floswitch™ set

contents: BD Careflow™ quint lumen polyurethanecatheter with clear extensions, steel needle introducer,BD Floswitch™overneedle introducer, vessel dilator,BD Venaguide™ Seldinger wire advancing device,BD Floswitch™ revolving BD Luer-Lok™ system, scalpel,Luer Lock plugs and secondary fixation device.Sterile double tray packaging for increased safety.

� Quint lumen BD Careflow™ without BD Floswitch™ setcontents: BD Careflow™ quint lumen polyurethanecatheter with clear extensions, cannula introducer, steelneedle introducer, BD Venaguide™ Seldinger wireadvancing device, extension slide clamps, 5ml syringe,scalpel, injection caps and secondary fixation device.Sterile double tray packaging for increased safety.

Sterilisation method� Ethylene oxide

Shelf life� 5 years

Class III according to European Medical Devices Directive93/42/EEC.

Page 87: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Critical Care and Haemodynamic Monitoring 91

CENTRAL VENOUS CATHETERSBD Hydrocath Assure™

Sterile, single use

Description� BD Hydrocath Assure™ is a range of single, double and

triple lumen polyurethane central venous catheters,designed for catheterisation by the Seldinger technique.

� Every catheter is coated with a hydrophilic substanceactivated by biological fluids, which facilitates the insertionof the catheter and reduces the potential adhesion ofbacteria or formation of thrombus.

� In addition, the Hydromer hydrophilic matrix isimpregnated with the antimicrobial agent BenzalkoniumChloride (BZC) .

� BZC is bactericidal against a broad spectrum of micro-organisms which are known to colonise central venouscatheters.

� BD Hydrocath Assure™ has been proven to reducebacterial colonisation of catheters in critically ill patients.*

BD Hydrocath Assure™ Set Componentry� All of the above sets contain: BZC impregnated and

hydrophilic coated polyurethane catheter, BD Venaguide™

Seldinger wire advancing system, needle introducer, veindilator and secondary fixation device.

� All sets without BD Floswitch™ contain a cannulaintroducer, needle introducer, sliding clamps and 5mlsyringe.

� All BD Floswitch™ sets include RLL BD Floswitch™,BD Floswitch™ cannula introducer and needle introducer.

Sterilisation method

� Ethylene oxide

Shelf life

� 2 years

Class III according to European Medical Devices Directive93/42/EEC.

BD Hydrocath Assure™ Single Lumen Sets

Catheter Catheter Cannula BD FloswitchTM Needle Guidewire Box Flow rate Code CodeExternal Length Introducer Introducer Introducer OD & Length content (ml/min) w/o withDiameter Gauge Length Gauge Length Gauge Length units D M P BD FloswitchTM BD FloswitchTM

(mm) (mm) (mm) (mm)

5Fr (16G) 200 16G 70 17G 70 0.9 x 700 5 56 681161

BD Hydrocath Assure™ Double Lumen Sets7Fr (16G, 18G) 200 16G 70 15G 70 17G 70 0.9 x 700 5 69 22 681152 6811507Fr (16G, 18G) 300 16G 70 15G 70 17G 70 0.9 x 700 5 61 17 681153 681151BD Hydrocath Assure™ Triple Lumen Sets7Fr (16G, 18G, 18G) 150 16G 70 15G 70 17G 70 0.9 x 450 5 68 22 24 681157 6811547Fr (16G, 18G, 18G) 200 16G 70 15G 70 17G 70 0.9 x 700 5 58 18 19 681158 6811557Fr (16G, 18G, 18G) 300 16G 70 15G 70 17G 70 0.9 x 700 5 50 13 13 681159 681156

* Reference: Moss MA, Tebbs SE, Faroqui MH, Herbst T, Isaac JL, Brown J, Elliott TSJ, “A central venous catheter coated with Benzalkonium Chloride for theprevention of catheter-related microbial colonisation”. Eur J Anaesth 2000, 17, 680-687.

Page 88: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Critical Care and Haemodynamic Monitoring92

ARTERIAL CATHETERS

Sterile, single use

BD™ Arterial Cannula

Gauge Length (mm) Box content Item numberunits

20G with BD Floswitch™ 45 25 682245

Description� Catheter designed for insertion into peripheral arteries, for

the determination of blood gas estimations or monitoringblood pressure.

� BD Floswitch™ on/off device prevents back-flow therebyreducing the risk of air emboli and potential contaminationof hospital staff by exposure to blood.

� ‘Venflon-like’ insertion characteristics.

� Wings to facilitate fixation.

Sterilisation method� Ethylene oxide

Shelf life� 5 years

Class IIa according to European Medical Devices Directive93/42/EEC.

Page 89: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Radial artery set 3Fr (20G) 60 20 40 0.5 x 250 10 0.08 681646[681750]

Radial artery set 2.5Fr (22G) 60 22 40 0.5 x 250 10 0.08 681631Femoral artery set 3Fr (20G) 200 20 40 0.5 x 450 10 0.14 681642Femoral artery set 4Fr (18G) 200 17 70 0.6 x 450 10 0.24 681648

[681751]

93

ARTERIAL CATHETERSBD Careflow™ Arterial Catheters

Sterile, single use

Description� BD Careflow™ polyurethane catheters are designed for

access to radial or femoral arteries, for the determinationof blood parameters or monitoring blood pressure.

� Catheterisation trays contain an introducer needle, metalguidewire and Luer Lock plug.

Sterilisation method� Ethylene oxide

Shelf life� 5 years

Class III according to European Medical Devices Directive93/42/EEC.

Critical Care and Haemodynamic Monitoring

Description Catheter Needle Guidewire Box Priming Item numberExternal Length Introducer OD & content Volume [No. for PL, CZ,Diameter (mm) Gauge Length (mm) Length (mm) units (ml) HU, SK]

Page 90: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Critical Care and Haemodynamic Monitoring94

PULMORY PERCUTANEOUSSHEATH INTRODUCER SETS

Sterile, single use

BD Exacta™

Size (Fr)† PU Cannula Needle Guidewire Contamination High-Flow Syringe Scalpel Obturator Box Item number

Introducer Introducer Introducer OD & Shield Stopcock content [No in PL, CZ, HU, SK]

Length (mm) Gauge & Length (mm) Gauge & Length (mm) Length (mm) Length (mm) units

6.0 100 16G x 70 17G x 70 0.9 x 450 800 Yes Yes Yes Yes 5 680128 [680339]7.0 100 16G x 70 17G x 70 0.9 x 450 800 Yes Yes Yes Yes 5 680140 [680340]8.0 100 16G x 70 17G x 70 0.9 x 450 800 Yes Yes Yes Yes 5 680126 [680338]8.5 100 16G x 70 17G x 70 0.9 x 450 800 Yes Yes Yes Yes 5 680124 [680337]

Percutaneous Sheath Introducers for the introduction of Pulmonary Artery Catheters

† for introduction of 1 Fr smaller size catheters

Description� A complete range of polyurethane sheath introducer

systems.

� Integral side-arm.

� Tuohy-Borst adapter and haemostasis valve.

� BD Exacta™ sets include a contamination shield withTuohy-Borst lock.

� Individually packed, sterile, non-pyrogenic and radiopaque.

How BD Exacta™ Introducers can benefit you� Polyurethane sheath reduces risk of thrombus formation

in-situ.

� Flexible hub minimises potential for kinking of introducers.

� Profiled sheath tip and matched dilator facilitates smooth,atraumatic insertion.

.� Tuohy-Borst adapter minimises catheter migration and

improves catheter control.

� Self-seal haemostasis valve minimises risk of blood loss.

� BD Venaguide™ Seldinger wire advancing device allowssingle handed wire insertion.

� Sterile double tray packaging for increased safety.

Sterilisation method� Ethylene oxide

Shelf life� 3 years

Class III according to European Medical Devices Directive93/42/EEC.

Page 91: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

95

PULMORY ARTERY &THERMODILUTION CATHETERSBD Criticath™

Sterile, single use

SP5105H 5Fr 80 4 Yes Yes Yes Yes 5 680084SP5107 7Fr 110 4 Yes Yes Yes No 5 680098SP5107H 7Fr 110 4 Yes Yes Yes Yes 5 680078

[680333]

SP5107H-14 7Fr 110 4 Yes Yes Yes Yes Pre-mounted BD Luer-Lok™ AC shield 5 680088[680036]

SP5107+SP5045 7Fr 110 4 Yes Yes Yes No Pre-mounted In-Line Inject. sensor 5 680099SP5107H+SP5045 7Fr 110 4 Yes Yes Yes Yes Pre-mounted In-Line Inject. sensor 5 680077SP5127 7 Fr 110 4 Yes Yes Yes No "S" shaped to facilitate femoral insertion 5 680104SP5127H 7 Fr 110 4 Yes Yes Yes Yes "S" shaped to facilitate femoral insertion 5 680089SP5507 7.5Fr 110 5 Yes Yes Yes Yes No 5 680102SP5507H 7.5Fr 110 5 Yes Yes Yes Yes Yes 5 680082

[680334]

SP5507H-14 7.5Fr 110 5 Yes Yes Yes Yes Yes Pre-mounted BD Luer-Lok™ AC shield 5 680093SP5507HS 7.5Fr 110 5 Yes Yes Yes Yes Yes "Soft" version 5 680080SP5507+SP5045 7.5Fr 110 5 Yes Yes Yes Yes No Pre-mounted In-Line Inject. sensor 5 680100SP5537 7.5Fr 110 5 Yes Yes Yes Yes No 5 680106SP5537H 7.5Fr 110 5 Yes Yes Yes Yes Yes 5 680081VascoStim 2Fr 150 Yes For use with model no. SP5537 catheters 1 0501-089trans-luminalpacing lead

Catheters for monitoring Right Heart Pressures and Cardiac Output MeasurementModel Size Length Number PA CV Cardiac CVP Ventric. Hepar Additional Box Item Number

(Fr) (cm) of lumens wedge pressure Output medic. pacing -inised information content [No. for PL, CZ,pressure port units HU, SK]

Description� A range of flow directed, balloon tipped catheters for both

adult and paediatric use.

� Use for monitoring right heart pressures and obtainingvenous blood samples.

� Thermodilution technique used to measure CardiacOutput.

� Options include temporary ventricular pacing and ‘S’ tippedfor femoral insertion.

� Also available in hard and soft versions.

� Individually packed, sterile and non-pyrogenic.

How BD Criticath™ can benefit you� Rounded catheter tip design allows for smooth insertion

and reduces risk of vessel trauma.

� Heparin coating minimises risk of thrombus formation.

� Strong circular lumen design reduces kinking andenhances pressure signal transfer.

� Catheter depth markings facilitate accurate placement andcatheter manipulation.

� Smooth balloon/catheter junction reduces risk of balloonrupture and thrombus formation.

� Some models have a pre-mounted in-line injectate sensorhousing or an anticontamination (AC) sheath on thecatheter for user convenience.

Sterilisation method� Ethylene oxide

Shelf life� 2 years

Class III according to European Medical Devices Directive93/42/EEC.

Critical Care and Haemodynamic Monitoring

Page 92: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Critical Care and Haemodynamic Monitoring96

ICE/ROOM TEMPERATUREINJECTATE SYSTEMS

Sterile, single use

BD Critikit™

Closed loop in-line injectate systems for improved accuracy of cardiac output measurement

Description� Available in both iced and room temperature injectate

options.

� Closed circuit design offers an aseptic approach to cardiacoutput measurement.

� Individually packed, sterile and non-pyrogenic.

� Set comprises an injectate sensor housing with three waystopcock, one way check valve, Spectraject 10cc syringe,cooling coil, delivery tubing and IV spike.

How BD Critikit™ can benefit you� Closed loop system reduces risk of line contamination.

� Insulated volume-restricted syringe facilitates precise andreproducible injectate.

.� In-line injectate sensor optimises accuracy of temperature

readings.

� Syringe design allows smooth injectate action improvingdata validity.

Sterilisation method� Ethylene oxide

Shelf life� 5 years

Class IIa according to European Medical Devices Directive93/42/EEC.

Model Description Sterile Box content Item Nounits [No in PL, CZ, HU, SK]

SP4500 Ice/ Room temperature Injectate BD Critikit™ Yes 4/8 680000(with in-line sensor, Control syringe & Cooling coil) [680342]

SP4572 Room temperature Injectate BD Critikit™ Yes 5/20 680178(with in-line sensor, Control syringe w/o Cooling coil)

SP5045 In-line injectate sensor housing Yes 25/250 680006[680331]

Spectraject 10cc control syringe Yes 10/50 682155

SP4042 In-line injectate sensor cable. For use with Abbott Oximetrix, Arrow, BaxterEdwards 9520A or Com1, Mennen Horizon 2000 Series (cable 800-030-200), No 1 684056

Spacelabs Alpha PC or PCMS (bifurcated cable model 306655-001), Datex AS3and BD Critikit™ Injectate set or SP5045 sensor housing.

SP4044 In-line injectate sensor cable. For use with Marquette Cardiac Output Module No 1 684059and BD Critikit™ Injectate set or SP5045 sensor housing.

SP4045 In-line injectate sensor cable. For use with HemoPro (SP1445), Nikon Kohden,Spacelabs (bifurcated cable model 306655-002), Fukuda Denshi IB5006 (DSCP), No 1 684062

Dynascope DS3300 and BD Critikit™ Injectate set or SP5045 sensor housing.SP4046 In-line injectate sensor cable. For use with Hewlett Packard Cardiac Output

Module (HP trifurcated cable M1641A or M1642A) and BD Critikit™ Injectate set No 1 684063or SP5045 sensor housing.

SP5500 Ice container for use with BD Critikit™ (SP4500). No 4 684004SP5555 Bracket for pole mounting ice container. No 5/50 682161

Non-Sterile Accessories:

Class I according to European Medical Devices Directive 93/42/EEC.

Model Description Sterile Box content Item Numberunits

Page 93: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

97

PRESSURE TRANSDUCER SETSBD DTXPlus™ Disposable Pressure Transducers

Sterile, single use

Critical Care and Haemodynamic Monitoring

BD DTXPlus™ Disposable Pressure Transducer SetsDesigned for ease of use and minimal wavelength distortion

Haemodynamic monitoring information is used to manage the care of critically ill patients. It is therefore essential that you areconfident about the accuracy of the information that you are using. Fluid filled pressure monitoring systems will cause somedistortion to the pressure waveform. Up to 40% distortion has been shown in some cases.1

Accuracy in pressure monitoring isn’t just dependent on the transducer, it’s dependent on all the components in the pressuremonitoring system; catheter, pressure tubing, monitor filter and stopcocks. It has been shown

2that in order to know the accuracy of

your system, you need to consider the performance of the total chain where all the components are linked together.

As a manufacturer we believe we have a responsibility to provide you withinformation about the accuracy of the whole monitoring system, not just thetransducer. Therefore, BD has selected a range of standard BD DTXPlus™ setswhich are Gabarith tested.

2

The BD Gabarith™ test remains the only scientific technique that providesinformation about the dynamic response performance of the total pressuremonitoring system (total chain).

The BD Gabarith™ test assesses the system against pre-set windows of error(2%, 5% and 10% waveform distortion). For example: If the dynamic response ofa pressure chain falls within the 10% Gabarith window then we know the pressurewaveform will not be distorted by more than 10%.

3

Windows of tolerance are based on catheter tip sensor results (the ’gold’ standard) using real patient data.

Every box of BD DTXPlus™ pressure monitoring sets is stamped with the BD Gabarith™ symbol. This shows that the set haspassed the BD Gabarith™ test and has a known level of accuracy. The BD Gabarith™ test exceeds the demands of the AAMIstandard (Association for the Advancement of Medical Instrumentation).

References:1 Anesthesiology 53: 498-504, 1980; British Journal of Anaesthesia 1987, 59, 901-912; European Academy of Anaesthesiology - Strasbourg Aug/Sep 1997

(Bender HJ, Billiet E et al).2 Billiet E, Colardyn F. (1998) Pressure Measurement Evaluation and Accuracy: The Gabarith Test. Intensive Care Medicine 24:1323-13263 Assuming that the set has been set up and zeroed in accordance with manufacturing instructions

PRESSURE OUT

PRESSURE IN

1DYNAMICRESPONSE

TESTED SET ACCEPTEDAS WITHINGABARITHWINDOW

TESTED SET DISCARDED AS OUTSIDEGABARITH WINDOW

Hz

Example of Radial Artery pressure10% error Gabarith window(for adult kit)

0 10

GABARITHWINDOW OFTOLERANCE

Page 94: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Critical Care and Haemodynamic Monitoring98

PRESSURE TRANSDUCER SETS

Sterile, single use

BD DTXPlus™ Disposable Pressure Transducers

DT-XX Disposable transducer with Critiflex integral 10 682018 [682292]flush device and stopcock (3cc/hr nominal flow rate)

DT-NN Disposable transducer for neonatal/paediatric uses. 10 682019Used in conjunction with a mechanical infusion pump

(max. 30cc/hr flow rate)TNF-R Disposable transducer without integral flush device 10 682021

or stopcock. Suitable for cardiology/neurology applications

Model Description Box content Item numberunits [No. for PL, CZ, HU, SK]

Description� BD offers a wide range of disposable and reusable

transducers.

� BD’s experience is based on decades of research anddevelopment reaching back to the first practical bloodpressure transducer introduced by Gould-Statham.

Sterilisation method� Ethylene oxide

Shelf life� 5 years

Class IIa according to European Medical Devices Directive93/42/EEC.

Page 95: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

99

PRESSURE TRANSDUCER SETS

Sterile, single use

Critical Care and Haemodynamic Monitoring

BD DTXPlus™ Flexi Transducer System

Description

Cost effectiveness:� BD DTXPlus™ Flexi Transducer System allow savings on

the set-up time and storage costs are minimized. Furthersavings through use of only one administration set, onesaline bag and one pressure cuff.

Efficiency:� Quick and easy to add or remove extra kits allowing

quick response to patient´s changing condition� Less Tubing� Less Work� Less Waste

Safety:� Safe arterial blood sampling versions of the BD DTXPlus™

Flexi Transducer System are available for added safetyduring arterial blood sampling procedures

Sterilisation method� Ethylene oxide

Shelf life� 5 years

Class IIa according to European Medical Devices Directive93/42/EEC.

Description Admin. Set Line Colour and Length Box content Itemunits Number

Arterial kit Yes Red, 175 cm 5 686562Arterial kit, Thorax Yes Red, 175 cm 5 686340Arterial kit, Safedraw Yes Red, 190 cm 5 686337Arterial kit, Safedraw, Thorax Yes Red, 190 cm 5 686585Venous kit Yes Blue, 175 cm 5 687715Arterial kit, Safedraw Yes Red, 190 cm 5 687714Venous kit No Blue, 175 cm 5 686495PA kit No Yellow, 175 cm 5 686496Pressure Universal No Clear, 175 cm 5 686572Safeneedle TA-BPN - - 50 682159

Clinicians require flexibility in the transducer set combinations that are needed during the monitoring of critically ill patients.The BD DTXPlus™ Flexi Transducer System provides a flexible solution to these needs.

Experience indicates that clinicians do not always require all the waveforms to be monitored on all patients at all times. Thisversatility is usually met by using only one line in a double kit or two lines in a triple kit or by holding stock of different kitconfigurations, often resulting in cost inefficiencies.

In the BD DTXPlus™ Flexi Transducer System, the arterial line is used as the "master" line (arterial waveform beingsystematically monitored). When clinically required, additional lines (eg. CVP or PA) are connected in a cascade via anadditional stopcock positioned on the administration set side of the transducer (no impact on dynamic response).

BD DTXPlus™ Flexi Transducer Set Range

Page 96: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Critical Care and Haemodynamic Monitoring100

PRESSURE TRANSDUCER SETS

Sterile, single use

BD Gabarith™ Disposable Transducer Sets

1 Billiet E., Colardyn F. Pressure Measurement Evaluation & Accuracy Validation: The Gabarith Test. Intensive Care Medicine (1998) 24: 1323-1326

Number of Flush/Flow rate Total Pressure line(s) Additional Box Item numberDisposable (cc/Hr) Pressure line colour information contentunits [No. for PL, CZ, HU, SK]Transducers length (cm)

1 3 150 Clear with BD R.O.S.E.™ 5 682001 [682287]1 3 150 Clear 5 682002 [682288]1 3 150 Red 5 682004 [682289]1 3 150 Blue with BD R.O.S.E.™ 5 6820051 3 150 Blue 5 682006 [682290]1 3 150 Yellow Add-on set to set no. 682037, -38, -55 5 6820081 3 175 Red with BD R.O.S.E.™ 5 6820091 3 175 Red 5 6820101 3 25 Clear Velcro strap for arm mount 5 6820111 3 150 Blue with BD Multiflo™ 5-way 5 6820131 3 150 Clear w/ non-shunting stopcock & extension set 5 682017 [682291]1 30 160 small bore Clear For use with infusion pump 5 682022 [682293]1 30 35 small bore Clear For use with infusion pump 5 6820252 3 150/150 Red/Blue with BD R.O.S.E.™ on blue line 5 682030 [682294]2 3 150/150 Red/Blue 5 682032 [682295]2 3 150/150 Red/Blue with 3rd IV line for add-on set 5 6820372 3 150/150 Blue/Yellow 5 6820413 3 150/150/150 Red/Blue/Yellow 5 682046

Disposable Transducer Sets for the Invasive Monitoring of Haemodynamic Pressure

Description� Validation by unique BD Gabarith™ accuracy test.

� A range of single, double and triple disposable transducersets.

� Adult and paediatric options.

� BD Safedraw™, closed loop arterial blood samplingsystem available. (Please refer to next section).

� BD R.O.S.E™ (Resonance OverShoot Eliminator) includedin selected sets.

� Individually packed, sterile, non-pyrogenic and latex free.

� Adult pressure sets include rotating male luer for easy andtrouble-free connection onto the catheter.

How BD Gabarith™ sets can benefit you� Unique BD Gabarith™ testing of sets, using total

haemodynamic chain concept, offers the opportunity forimproved haemodynamic accuracy

1.

� BD Connecta™ Plus sampling and zeroing stopcocks withon/off snap for confirmation of stopcock positioning.

� Designed straight fluid pathway minimises the risk ofbubble entrapment and subsequent damping of signal.

� Robust monitor connection prevents water penetration andoffers back pressure calibration facility.

� Unique BD EasyVent™ zeroing deadender minimises riskof touch contamination.

� Wide range of transducer set configurations coveringneonatal to adult pressure monitoring requirements.

Sterilisation method� Ethylene oxide

Shelf life� 5 years

Class IIa according to European Medical Devices Directive93/42/EEC.

Page 97: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

101Critical Care and Haemodynamic Monitoring

PRESSURE TRANSDUCER SETS

Sterile, single use

BD Safedraw™ Safe Arterial Blood Sampling

1 3 155 Clear 3cc syringe restricted to 2cc 5 6820271 3 155 Clear 5cc sheathed syringe restricted to 2cc 5 682051 [682303]1 30 135 Clear For use with infusion pump/5cc sheathed 5 682052

syringe restricted to 1cc2 3 155/150 Clear/Blue 5cc sheathed syringe restricted to 2cc & 5 682053

with BD R.O.S.E.™ on blue line2 3 155/150 Clear/Blue 5cc sheathed syringe restricted to 2cc 5 6820542 3 155/150 Clear/Blue 5cc sheathed syringe restricted to 2cc & 5 682055

with 3rd IV line for add-on set3 3 155/150/150 Clear/Blue/Yellow 5cc sheathed syringe restricted to 2cc 5 682056

Closed loop arterial blood sampling disposable Transducer Sets for the Invasive Monitoring of Haemodynamic Pressure

Model Description Box content Item numberunits [No. for PL, CZ, HU, SK]

TA-STV BD Safedraw™: BD Vacutainer® Transfer Device 25 682158TA-BPN BD Safedraw™: BD Luer-Lok™ Safe-Needle 50 682159 [682301]

Number of Flush/Flow rate Total Pressure line(s) Additional Box content Item numberDisposable (cc/Hr) Pressure line colour information units [No. for PL, CZ, HU, SK]Transducers length (cm)

Description� BD Safedraw™, unique system for closed loop arterial

blood sampling.

� BD Safedraw™ arterial sampling system reduces the riskof cross contamination and blood spillage to patients andstaff whilst facilitating blood sampling.

� Significantly reduces the risk of iatrogenic anaemia.

� A range of single, double and triple disposable transducersets

� Adult and paediatric options.

� Individually packed, sterile, non-pyrogenic and latex free.

How BD Safedraw™ sets can benefit you� BD Safedraw™ significantly reduces unnecessary blood

discard and blood spillage. Significantly reduces the risk ofcross contamination and iatrogenic anaemia.

� BD Safedraw™ facilitates easier sampling and superiorclinical samples, thereby achieving more reliablelaboratory values.

� Unique BD Gabarith™ testing of sets, using totalhaemodynamic chain concept, offers the opportunity forimproved haemodynamic accuracy.

Sterilisation method� Ethylene oxide

Shelf life� 5 years

Class IIa according to European Medical Devices Directive93/42/EEC.

Page 98: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Critical Care and Haemodynamic Monitoring102

PRESSURE TRANSDUCER SETSBD™ Reusable Pressure Transducers,Disposable Domes and Accessories

Model Description Box content Item numberunits [No. for PL, CZ, HU, SK]

TA1015T For P23XL and P23ID with integrated BD Critiflow™ flush device (3cc/hr) 10 682058 [682296]TA1017 For P10EZ and P50 with integrated BD Critiflow™ flush device (3cc/hr) 10 682059TA1018 For P10EZ and P50 with integrated BD Critiflow™ flush device (30cc/hr) 10 682065TA1019 For P10EZ and P50. Rotating Luer fitting 12 682089TA1010ND For P23XL and P23ID. Rotating Luer fitting 12 682084TA4005 BD Critiflow™ flush device (30cc/hr) 10 682063TA4004 BD Critiflow™ flush device (3cc/hr) 10 682060

P23XL-1 Standard size (non-sterile) 1 684000 [684256]P10EZ-1 Minaturised (non-sterile) 1 684001TA9007 Transducer holder for 2 P23XL 10 682103TA9010 Transducer holder for 4 P23XL 5 682061

BD™ Transducer Interface Cables see page 105-115

Reusable transducers and accessories are Class I according to European Medical Devices Directive 93/42/EEC

Model Description Box content Item numberunits [No. for PL, CZ, HU, SK]

BD™ Disposables Domes and Accessories

Description� BD’s expertise with reusable transducers is based on a

long experience of research and development initiated bythe first transducers designed by Gould-Statham.

� BD’s reusable transducers are fitted with a standardwiring. They can be connected to most of the existingmonitors thanks to the wide range of BD™ TransducerInterface Cables.

� BD’s disposable domes are equipped with a membrane tofacilitate aseptic techniques.

Disposable dome sterilisation method� Ethylene oxide

Shelf life� 5 years

Disposable domes are class IIa according to EuropeanMedical Devices Directive 93/42/EEC.

BD™ Reusable Transducers

Page 99: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

103Critical Care and Haemodynamic Monitoring

PRESSURE TRANSDUCER SETSBD™ RT2000 Reusable Transducer andDisposable Domes for RT2000

Model Description Box content Item numberunits

RT2000 BD reusable blood pressure transducer for fluid-filled column application. 10 682266DD2000 Disposable dome for coupling with RT2000 w/o integral flow/flush device and 10 682265

and zeroing stopcock.DD2003 Disposable dome for coupling with RT2000 with integral flow/flush device and stopcock 10 682263

(3 ml/hr nominal folw rate) and zeroing stopcock.

BD has a proud heritage evolving originally from StathamInstruments and has continuously developed new technologyto enhance patient care.

With the BD™ RT2000 transducer system, BD is offering anew generation of reusable blood pressure transducers forfluid-filled column application, with highest standards insafety, reliability and convenience.

Description� Snap-on dry coupling set-up

� Integrated components of flush device and ventingstopcock in dome provide for quick, effective fluid controlwhile reducing set-up time

� Superior dynamic response and reliability

� Fully integrated flush device and zeroing stopcock tominimize the risks of blood flash back and patient linecontamination

� Domes allow complete fluid path visibility to assurebubble-free filling thus minimizing the risk of air embolism

� Interface cable is designed as waterproof connection forlong lasting use

� Latex free

Disposable dome sterilisation method

� Ethylene oxide

Shelf life� 5 years

Disposable domes are class IIa according to EuropeanMedical Devices Directive 93/42/EEC.

Page 100: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Critical Care and Haemodynamic Monitoring104

PRESSURE TRANSDUCER SETSBD™ Pressure Lines, BD Connecta™ PE PressureLines and Pressure AccessoriesSterile, single use

Male/Female or Tubing Length Line colour Box content Item numberMale/Male Line Connection (cm) coding units [No. for PL, CZ, HU, SK]

M/F 25 Clear 25 682226M/F 100 Clear 25 682229M/F 150 Clear 25 682230M/F 200 Clear 25 682232M/M 100 Clear 25 682234M/M 150 Clear 25 682079 [682298]M/M 200 Clear 25 682236M/F 100 Red 25 682237M/F 150 Red 25 685185M/M 125 Blue 25 685190M/M 150 Blue 25 685171M/F 150 Yellow 25 686619

M/F 15 Clear (Red/Blue clips) 25 682194M/F 50 Clear (Red/Blue clips) 25 682185M/F 100 Clear (Red/Blue clips) 25 682189M/F 150 Clear (Red/Blue clips) 25 682191M/F 200 Clear (Red/Blue clips) 25 682192M/M 50 Clear (Red/Blue clips) 25 682186M/M 100 Clear (Red/Blue clips) 25 682190M/M 200 Clear (Red/Blue clips) 25 682193

BD™ Pressures Lines (PVC)

BD Connecta™ PE Pressure Monitoring Lines (PolyEthylene)

Description� BD™ Pressure Lines (PVC) for accurate transmission of

the pressure waveform.

� BD Connecta™ PE (PolyEthylene) lines as a non PVCalternative.

� Colour coded (red/blue) clips supplied with BD Connecta™

PE to facilitate line identification.

Sterilisation method� Ethylene oxide

Shelf life� 5 years

Class IIa according to European Medical Devices Directive93/42/EEC

Description� Cable Checker to check for cable continuity.

� BD™ Transducer Interface Cables - see page 105-115.

Class I according to European Medical Devices Directive93/42/EEC

Pressure Accessoiries (non-sterile)

TBG Transducer BackGround for pole mounting (up to 4 transducers) 10 682093 [682299]TMM Snap-On TMM Cable Organiser 5 682274 [682306]TMM/TBG TBG with Snap-On TMM Cable Organiser 5 682275Cable Checker Electrical tester for compatible interface cables 1 684003

Model Description Box content Item numberunits [No. for PL, CZ, HU, SK]

Page 101: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

105Critical Care and Haemodynamic Monitoring

For use with BD DTX™ Kits(Including BD DTXPlus™, BD Gabarith™, BD Safedraw™,Reusable BD™ RT2000 and P10/P23 Kits)� BD offers a comprehensive range of transducer cables to

suit most popular brands of monitors. We also offer cablesfor rarer or older monitors, so should you have arequirement for a model not shown then please contactyour local BD Office. (Telephone numbers on back cover.)

� BD also offers a “Flying Lead” option (684109), which isavailable where BD does not offer a connection cable foryour monitor.

� In addition, all BD™ Transducer Cables require an“O Ring” (683039) to be attached to the “BD Cable end”,which ensures a vacuum when plugging into thetransducer kit.All Cables come fitted with this, however these are alsoavailable separately, as these can wear down andsometimes require replacing.

� When purchasing cables please specify:1. Monitor type.2. Model number and/or serial number.

� Non-sterile items.

Class I according to European Medical Devices Directive93/42/EEC.

BD™ Transducer Interface Cables

Page 102: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Critical Care and Haemodynamic Monitoring106

PCN Page684056 Abbott Oximetrix 114684059 Marquette Cardiac

Output Module 114684062 HemoPro (SP 1445) 115684063 Hewlett Packard

Cardiac Output Cable 113684078 Datascope 108684081 Phillips 108684082 Drager/Siemens 109684084 Spacelabs 108684085 Viatek/Criticon/

Spacelabs/Tektronics/Nellcor/Medtronic 108

684086 Hellige (Litton) 109684087 Mennen 112684090 Nihon Kohden 108684091 Narco (Airsheild) 112684096 Marquette (GE) 108684102 Marquette (GE) 109684104 Datex Ohmeda/

Burdick 109684109 No Monitor conn. 110684119 AVCO 113684120 Siemens 113684121 Drager/Siemens 110684128 E for M/Honeywell/

Drager/Phillips 109684129 Kontron 110684134 Quinton 110684138 Jostra 109684138 Sarns 113

PCN Page684139 Shiley 113684147 Dantec (Disa) 113684150 Fukuda Denshi 114684167 PPG Biomedical/

Hellige/Marquette 110684175 Schwarzer 110684178 Drager/Siemens 111684179 BARD 114684181 Prucka 111684188 Stockert 112684200 Colin 114684204 Medical Measurement

Systems (4ft Cable) 111684216 Corometrics 114684227 Spacelabs 111684236 Drager/Siemens 111684242 Medical Measurement

Systems (12ft cable) 111684243 Stockert 112684260 Mennen 112JP-900P Nihon Kohden 112

BD™ Transducer Interface Cables -Cables Index

Page 103: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

107Critical Care and Haemodynamic Monitoring

Datex Ohmeda/Burdick (GE) -

Pin configurationNumber of pinsM = PinsF = Holes

Model type

BD™ Transducer Interface Cables -Guide to terminology

684104 – 10 Pin F – LF Part number

Status if knownLF = latex freeNLF = not latex free

M565 PDM /Cardiocap CC104 / AS3 /Cardiocap II / Datex AS3 / S5SYS 800, MOD 8641,SIVA 3000

Manufacturer

Page 104: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Critical Care and Haemodynamic Monitoring108

684078 - 6 Pin F - LF

Datascope - All Models

684084 – 5 Pin M - LF

Spacelabs - Alpha 700 Series

684090 – 5 Pin M - LF

Nihon Kohden - MFV1100, 1200,1230A; Lifescope 8, 9, 11, 12, 14,BSM-8300J/K, 3000, BSM4100

684081 – 12 Pin M - LF

Phillips (Hewlett Packard) -78341A, 78342A, etc. / 78354C78205A-D, 12-pin / 78352,CMS (Merlin line), M1006A/B,M1026A / M1166A / Viridia /HP Scop Eurelie 24C, CMS2001,V24,V26,M2,M3,M4, Intelivue

684085 – 6 Pin M - LF

Vitatek - Series 400, 500Protocol Propaq - ProtocolPropaq series; Propaq 106ELCriticon - DynamapSpacelabs - Series 400, 500,90308/11/31, MOD-CD, CD-CVTektronics - 400 SeriesNellcor - Escort 300 MDEVitalert - 2000Physiocontrol (Medtronic) - Lifepack12Zoll - Zoll Defribrillators

684096 – 8 Pin M - LF

Marquette (GE) - 7000 series,7010, Mod 7200

Page 105: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

109Critical Care and Haemodynamic Monitoring

684082 – 10 Pin M - LF

Dräger/Siemens -400 Series, 960, 961,Sirecust 4041,700,1260, 342, 732, Sirecust 342, 4XX,7XX, 9XX, 12XXDelta (SC7000), Kappa (SC8000),Delta XL (SC9000),with 10 pin connector

684086 – 6 Pin M - LF

Hellige (Litton) -4th/5th Generation / SMC 108 /Servomed / SMU 610, 611.612,SMU EVO

684102 - 11 Pin M - LF

Marquette (GE) - 7009/TramscopeSeries(600SL) - Eagle-Solar 8000Solar 9000, Eagle3000/1000,Mab Lab 6Fx3F, Tram 450SL,6200, Tram600A, EK36,Dash 3000, Dash 4000

684104 – 10 Pin F - LF

Datex Ohmeda/Burdick (GE) -M565 PDM /Cardiocap CC104 / AS3 /Cardiocap II / Datex AS3 / S5SYS 800, MOD 8641,SIVA 3000

684128 – 10 Pin M - LF

E for M/Honeywell - RM300

Dräger/Siemens - PM8040, PM8060,Dräger Vitara, Cato, Cicero &Julian Anes. machine

Phillips - CM140

684138 – 5 Pin M

Jostra(Heart pump)

Page 106: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Critical Care and Haemodynamic Monitoring110

684109 – Pin N/A - LF

No monitor connection (flying lead)WIRING GUIDE - The wiring codes on the cable are:Green Excitation voltageRed Excitation voltageBlack SignalWhite SignalShield Depends on the monitor being used.

Refer to individual design specification.

684129 – 12 Pin M - LF

Kontron, Arrow - Minimon 71317132 etc, K2000, 7272 /Supermon 7210 / Cart 2 PlusBalloon Pump, Oxford ACAT1

684167 – 10 Pin M - LF

PPG Biomedical/Hellige/Marquette -MIDAS; Hellige Midas 5000,2500, 2100 series

684121 – 15 Pin M - LF

Dräger/Siemens -Siereg/Sicor BPA 863(15-pole Cannon Connector),Mingograph 6 Cathcor, Recor

684134 - 6 Pin M - LF

Quinton - Q-cath lab system

684175

Schwarzer - MX960Criticare - MATRIX, Scholar 2200

Page 107: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

111Critical Care and Haemodynamic Monitoring

684178 – 7 Pin M - LF

Dräger/Siemens -6004, SC6002XL, SC6802XLSC 6000P, 6002, 5000Delta (SC7000), Kappa (SC8000),Delta XL (SC9000),Gamma/XL (SC6000) transportmonitor, all with 7 pin connector

684204 – 4 Pin M - LF

Medical Measurement Systems -UPS-2020 (4ft cable)

684236 – 15 Pin M - formerly 684199

Dräger/Siemens -HemoPod adapter

684181 – 8 Pin M

Prucka Eng Inc. -CARDIOLAB II / 1.1, AMP II

684227 – 6 Pin M - LF - identical to P/N 684085

Spacelabs (Vitatek) / BCI -400, 500, 90485Alpha-PC, 90603A, BCI 9100,90303B, Mod 90470-05,CD-CV, 90369, 90385, 90470,90496Ultraview 1600

684242 – 4 Pin M - LF

Medical Measurement Systems -UPS-2020 (12ft cable)

Page 108: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Critical Care and Haemodynamic Monitoring112

684243 – 4 Pin M - LF

Stockert - Heart Lung Machine

684260 – 8 Pin M - LF

Mennen - Envoy

JP - 900P - OTCN KB559

Nihon Kohden - NK9000

684087 – 6 Pin M - LF

Mennen -Horison 9000, H2200, XL, 1000

684188 - 4 Pin M

Stockert - S3

684091 – 10 Pin F - LF

Narco (Airshield); Kone; S&W -Narco AS100; Kone Press Amp.542,544,575; S&W Sytem 8000 &9000, Diascope II / Anaesthetic/Neonatal/Traveller, Athena

Page 109: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

113Critical Care and Haemodynamic Monitoring

684119 – 6 Pin M - LF

AVCO - Balloon Pump

684120 - 5 Pin F - LF

Siemens - 2nd Generation,Sirecust 300 Series

684138 – 5 Pin M

Sarns

684139 – 6 Pin M

Shiley, Cobe - Perfusion Controller

684147 – 5 Pin M - LF

Dantec (Disa) - Urodyne 5000

684063 – Model SP4046

Hewlett Packard Cardiac OutputModule (HP trifurcated cable M1641Aor M1642A) and Critikit Injectate set orSP5045 sensor housing

Page 110: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Critical Care and Haemodynamic Monitoring114

684200 – 5 Pin M

Colin - TC-COL-2

684216 – 12 Pin M - LF

Corometrics - Model 556

684056 – Model SP4042

Abbott Oximetrix, Arrow, BaxterEdwards 9520A or Com1, Mennen Horizon2000 Series (cable 800-030-200),Spacelabs Alpha PC or PCMS(bifurcated cable model 306655-001),Datex AS3 and Critikit Injectate set orSP5045 sensor housing

684059 – Model SP4044

Marquette Cardiac Output Moduleand Critikit Injectate set orSP5045 sensor housing

684150 – 12 Pin M - LF

Fukuda Denshi / Datascope -Dynascope DS-3300, DS-5000;Datascope Expert

684179 – 8 Pin M

BARD -LAB SYSTEM 24,Counterpilsation

Page 111: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

115Critical Care and Haemodynamic Monitoring

684062 – Model SP4045

HemoPro (SP1445), Nikon Kohden,Spacelabs (bifurcated cable model306655-002), Fukuda Denshi IB5006 (DSCP),Dynascope DS3300 and Critikit Injectate setor SP5045 sensor housing

Page 112: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

SU

RG

ICA

LA

CC

ES

SO

RIE

S

Page 113: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Surgical Accessories118

Sterile, single use

SURGICAL ACCESSORIESBD™ LeVeen Peritoneo Venous Shunt

Description Box content Item numberunits

BD™ LeVeen Peritoneo Venous Shunt 1 378542

Description

Method of operation of shuntThe BD™ LeVeen Peritoneo Venous Shunt is made up ofthree parts:� Intraperitoneal tube� One-way pressure valve� Venous tube

After surgical implant of the valve, the ascitic fluid enters theintraperitoneal tube, flows through the one-way valve and thevenous tube, and empties into the vena cava. The fluid ispropelled through the shunt when a positive pressurevariation of 3 cm water is reached between the intraperitonealpressure and the central venous pressure.

Results obtained with the shuntStudies conducted to date have shown that a few days afterthe operation patients usually display:

� Reduced abdominal perimeter.

� Reduced body weight.

� Increased excretion of urine.

� Decrease in hepatic coma and encephalopathy due toimproved renal function.

� Greater mobility.

� Plasma protein concentrations closer to normal.

Recommended uses� Peritoneal drainage in case of :

- Cirrhosis;

- Budd-Chiari syndrome;

- Chylous ascites;

- Uraemic or nephrogenic ascites;

- Hepatitis;

- Neoplastic ascites.

� Contraindications:

- Peritonitis;

- Haemorrhagic oesophageal varices;

- Renal failure;

- Bilirubin level above 10 mg/dl.

� Care to be taken with:

- Oesophageal varices without bleeding;

- Neoplastic ascites;

- Associated heart disease.

Packaging� Individually packed in sterile peel-back double packaging.

Sterilisation method� Ethylene oxide

� CE marked

� Latex free

Page 114: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

119Surgical Accessories

SURGICAL ACCESSORIES

Description Box content Item numberunits

BD Bard-Parker™ Heimlich chest valve 10 373460

Description� The Heimlich chest drain valve is a specially-designed

flutter valve used to replace underwater bottles in chestdrainage

� Constructed of rubber tubing, the valve is compresed atone end to form leaflets that control unidirection flow.

� The valve is encased in a transparent plastic chamber withtapered ends.

� The proximal end of the casing can be attached to mostchest catheters and the distal end to tubing that emptiesinto a plastic bag.

� If desired, the distal end can be connected to regulatedsuction.

Sterilisation method� Ethylene oxide

Shelf life� 5 years

� CE marked

� PVC free, not Latex free

BD Bard-Parker™ Heimlich Chest DrainValveSterile, single use

Page 115: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Surgical Accessories120

SURGICAL ACCESSORIESBD E-Z Scrub™

Single use

Description Concentration of Active Ingredient Box content Item numberunits

BD E-Z Scrub™ Brush / Sponge with Emollients Minimum 3% PCMX 30 371167BD E-Z Scrub™ Brush / Sponge sterile without Detergent Dry 30 371607BD E-Z Scrub™ Brush / Sponge with Povidone Iodineconcentrated Dry - 1% Minimum Available Iodine 30 372057BD E-Z Scrub™ Brush / Sponge with CHG 4% with Chlorhexidine Gluconate 30 377477

Description of scrub brushes� BD™ single use scrub brushes have soft polyethylene

bristles on one side and a polyether sponge on the other.Ergonomically designed for greater user comfort andeffectiveness.

Antiseptic agent� BD E-Z Scrub™ scrub brushes are supplied dry or

impregnated with Povidone Iodine, Chlorhexidine or PCMX(Parachlorometaxylenol). Concentration and volume havebeen determined to ensure antiseptic cleaning of handsand forearms.

Rigidity� The standard rigidity of BD E-Z Scrub™ scrub brushes has

been designed to provide the efficacy and comfort neededfor surgical scrub brushes. Their tapered design allowsfor two degrees of softness, appropriate for different areasof skin conditions. The inner recessed bristles are stifferand designed specially to remove dirt from beneath thenails. The sponge provides cleaning for gentle use onirritated areas, or when/where severe mechanical action orbrushing is not required, such as arms and forearms.

Recommended use� Surgical scrubbing of hands before wearing sterile gloves

for aseptic procedures.

Sterilisation method� Sterile brushes: Gamma irradiation (only dry brushes)

Description applicable to all scrub brushes� Dimensions : Length: 8 cm

Width: 5 cmHeight: 4 cm

� Strong cardboard boxes

� Dimensions of boxes: 125 x 125 x 540 mm

Accessories� Wall-mounting support

Accessories Concentration of Active Ingredient Box content Item numberunits

Scrub Dispenser - 1 371901

Page 116: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

AN

NE

X

Page 117: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

122 Annex

Social Responsibility - Trusted Partners

The BD “Trusted Partners” campaign was launched in early 2003.

The campaign highlights the partnerships BD has formed with philantropic, government andnongovernmental agencies for more than 100 years in order to make a significant impact onhealthcare and to save lives throughout the world.

The “Trusted Partners” initiative focuses on the relationship of BD with prominent nonprofitorganizations and describes the work being done through the partnerships to address some ofthe world’s most important and fundamental health issues. Through philantrophy, sustainablebusiness efforts and the development of pioneering technologies, BD is helping to support thedevelopment of an effective AIDS vaccine, eliminate deadly diseases (including measles andmaternal and neonatal tetanus), protect against smallpox, fight the spread of diseases andprovide relief in the wake of natural and manmade disasters.

These initiatives are an essential element of the commitment of BD to pursue its purpose of“helping all people live healthy lives.”

DIABETES: The leader in diabetes care since 1924, BD has the world’s mostcomplete array of insulin delivery and monitoring products, donates millions of dollarsto research and develops educational programs for diabetes patients.

AMERICARES: Since 1986, BD and AmeriCares have partnered to make a positiveimpact on healthcare globally by responding to emergency medical needs andsupporting humanitarian assistance programs.

HIV/AIDS: BD is committed to the battle against HIV/AIDS for future generations onmany fronts with partner organizations, such as the William J. Clinton PresidentialFoundation, the Global Business Coalition on HIV/AIDS, the International AIDSVaccine Initiative and Save the Children.

Page 118: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Annex 123

Social Responsibility - Trusted Partners

From the earliest civilizations through most of thelast century, smallpox claimed the lives of untoldmillions. By 1980, this virus had been eradicated.Yet today, the threat of smallpox looms once again as a possible weapon in a bioterrorist attack.

Governments throughout the world are part-nering with leading private sector companies toplan for the possibility of a bioterrorist attack bypreparing large-scale immunization programs.

Partners on the front line

Please visit www.bd.com. BD and BD Logo are trademarks of Becton, Dickinson and Company. © 2003 BD. photo © Evans/Getty Images

Almost 50 years ago, BD developed the first disposable syringes for mass delivery of the Salk polio vaccine. Now, BD is partnering withgovernments worldwide to challenge thethreats posed by bioterrorism.

The BD™ Bifurcated Needle, designed forthe delivery of the smallpox vaccine, is beingshipped to countries around the world. It was recently recognized as a “SignificantMedical Breakthrough“ by the U.S. FDA in its annual report.

In the clinical laboratory, highly sensitive BD plated media and fast-to-result analyticalinstruments are being used for rapid identifi-cation of bioterror agents.

And in the research laboratory, high performance flow cytometers from BD are studying the effects of bioterror pathogens on the immune system.

BD is a medical technology company serving some of the greatest needs of theglobal community. Healthcare institutions, life sciences researchers, clinical laboratories,industry and the general public all rely on BDproducts every day.

BD is privileged to partner with governments worldwide to protect life byaddressing emerging healthcare issues inevery corner of the world.

BD – Helping all people live healthy lives.

IAVI: BD has partnered with the International AIDS Vaccine Initiative (IAVI) to evaluateand identify vaccines that can prevent development of the AIDS virus.

PROJECT HOPE: Through an expansive “Train the Trainer” program, BD isperforming an influential role in the education of Chinese people about the preventionand treatment of diabetes.

UNICEF: The purpose of the UNICEF program is to eliminate maternal and neonataltetanus - a deadly health threat in many developing nations - by the year 2005.

AMERICAN RED CROSS: BD’s partnership with the American Red Cross supportsthe Measles Initiative, a commitment to vaccinate 200 million African children over 5years.

BIOTERROR: BD was on the frontline for polio vaccines and once again, BD is at theforefront in protection against smallpox.

HEALTHCARE WORKER SAFETY: In 1991, BD was founding sponsor of theUniversity of Virginia International Healthcare Worker Safety Center and primarysupporter of the EPINetTM Surveillance system, a database that tracks occupationalblood exposures. This partnership demonstrates BD’s leading efforts to protectcaregivers by designing devices with safety features.

Page 119: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

124 Annex

Quality Management with BD

BD Medical products are designed and manufactured to meet applicable internationalQuality Management System requirements in accordance with the European Medical DevicesDirective 93/42/EEC (MDD) and FDA QSR where applicable. Hence, all BD manufacturing siteshold a valid certification against ISO 9001:2000 and/or ISO 13485 and 13488 respectively.Likewise, all BD manufacturing sites are subject of periodic external as well as internal audits toensure compliance with aforementioned Quality Managment System requirements.

Symbol Guidance

Conformite European Use By Do Not Reuse

Catalogue number Date of Manufacture Latex Free

No PVCBatch Code

Authorized Representative

Method of SterilizationUsing Ethylene Oxide

Method of SterilizationUsing Irradiation

Keep Away from Sunlight

Fragile, Handle with Care

Keep Dry

Do Not Use If Packageis damaged

Green Dot Recycle forEurope

Caution, Consultaccompanying documents

This End Up

Manufacturer

Method of SterilizationUsing Steam or Dry Heat Peel Here

Page 120: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Annex 125

1. General

1.1 The General Sales Conditions shall apply to all offers (including offers by means ofproforma invoices), acceptances of purchase orders, sales, and deliveries of BDI.

1.2 The General Sales Conditions shall be deemed accepted by the Buyer if Buyer has notin writing clearly objected to them.

1.3 BDI objects to any general terms and conditions of the Buyer.1.4 All sales shall be non-exclusive and shall not confer any distribution or agency rights

unless otherwise specifically agreed.

2. Offers, oral statements and amendments

2.1 All offers by BDI shall be subject to alterations without prior notice. Any offer of BDI shallbe deemed withdrawn if it has not been accepted within the period there mentioned orwithin fourteen (14) days after its issue.

2.2 Any oral statement, addition or amendment to the General Sales Conditions and/or thedocuments of the related transaction shall only become valid if confirmed by BDI inwriting.

3. Purchase orders

3.1 Any purchase order shall be subject to BDI's approval but, however, may be acceptedimpliedly by simply effecting delivery.

3.2 Any purchase order shall identify the country of final destination.3.3 Products may normally be expected to be available, ready for shipment, within

reasonable time from BDI's acceptance of a purchase order but delivery, however,remain subject to BDI's manufacturing capabilities.

3.4 Any purchase order shall be of a minimum amount of 2,500.- US dollars. The Buyerplacing a purchase order below such minimum value shall pay to BDI a handling chargeof 250.- US dollars.

4. Prices

4.1 All quotations of prices are in US $ except as otherwise provided for in BDI's offer plus,even if not so mentioned in the respective offer, taxes or other charges as provided forby the applicable law.

4.2 The price payable by the Buyer for the products delivered shall be BDI's current price listwhich is effective at the date of delivery.

5. Payment

5.1 Payment shall become due at the date shown on the invoice or, if not mentioned, within30 days net of the invoice's date.

5.2 Delayed payments shall bear interest of 1,5 % per month which shall be paid by theBuyer to BDI and Buyer shall additionally reimburse BDI all costs and damagesassociated with delayed payment, legal expenses included.

5.3 In no event shall the Buyer have the right to retain or set off payments unless BDIconsented thereto in writing or a final and binding court decision confirms Buyer's claim.

5.4 If payment shall be effected by a letter of credit, BDI's Letter of Credit Policy shall apply.

6. Delivery and risk

6.1 Any delivery of BDI shall be "ex-works" (Incoterms 1990). However, on Buyer's request,BDI may provide, at Buyer's exclusive risk and cost, for transportation, legalisation,inspection, and any handling charges on usual terms.

6.2 If BDI has notified Buyer that the Products ordered are ready to ship, Buyer shall takedelivery without delay failing which all cost for storage and risk of loss or damage shallbe for Buyer's account.

6.3 Products are normally available within the time frame given in the purchase order asaccepted but, however, remain subject to manufacturing capabilities and schedules aswell as transportation facilities.

6.4 On BDI's request Buyer shall furnish customs clearance or any other documentationpertinent to the transaction.

7. Warranty

7.1 All products delivered shall be in compliance with the applicable specifications for therespective period of their shelf life.

7.2 In case of products being instruments the warranty shall be twelve (12) months from theinstallation date at the ultimate customer's facility but in no event to exceed eighteen (18)months as of delivery to the Buyer. However, any instrument warranty shall only be givenon the condition that the respective warranty and installation certificate of Becton wasproperly completed by Buyer.

7.3 The warranty shall neither cover products damaged in transit nor when the Buyer is indefault of acceptance. Mishandling, repairs or alterations of products without BDI'sauthorisation shall render any warranty void.

7.4 Any defects of products which would be apparent on reasonable inspection must benotified to BDI in writing within 72 (seventy-two) hours of reception of them by the Buyerfailing which the products shall irrevocably be deemed accepted by the Buyer.

7.5 Save as expressly provided for in this clause BDI shall have no liability or responsibilityto the Buyer in respect of defective products and all warranties regarding the quality,condition, durability, merchantability, fitness for purpose, conformity with samples, orlikewise are hereby expressly excluded.

7.6 Any warranty claim shall be in writing, using BDI's applicable complaint form, and identify

the defects and their presumable cause.

8. Retention of title

BDI reserves title to all products supplied to Buyer until such time as payment for therelevant delivery has been fully received by BDI.

9. Liability

9.1 Notwithstanding mandatory provisions of any applicable law, BDI shall neither be liablefor indirect or consequential damages nor for any other damages unless the latter werecaused by BDI's gross negligence or wilfulness.

9.2 BDI shall in no event be liable for any damage if it cannot be excluded that a fault of theBuyer or of a person for whom the Buyer is responsible caused the damage including,not limited to events identified in section 7.3 above.

10. Force Majeure

Neither party shall be liable for any breach of any agreement governed by the GeneralSales Conditions to the extent that this is caused by Force Majeure circumstances i.e.events which are beyond the reasonable control of the affected party, such as, but notlimited to, acts of god, strikes, work to rule, governmental acts, fire, flood, bad weatherconditions, war, shortfall of raw materials, energy, transportation, regardless of whetherthese were unforeseeable or not.

11. Termination

Any agreement governed by the General Sales Conditions may be terminated by BDIwith immediate effect if:

(i) without requirement for BDI to any further notice, the Buyer fails to pay at duedates, or

(ii) the Buyer is in material breach of any other term or condition of the General SalesConditions including the related agreement and has not remedied such breach withinfifteen (15) days of having been notified of such breach, or

(iii) the Buyer shall be or become bankrupt or insolvent or if there are instituted by or againstit proceedings in bankruptcy or under insolvency laws or for its reorganisation,receivership, liquidation, dissolution or change of ownership.

12. Amendments

The General Sales Conditions including any related agreement shall not be changed ormodified except by written agreement duly signed by BDI and Buyer.

13. Applicable Law and Jurisdiction

The General Sales Conditions and any related transaction shall be governed andconstrued in accordance with the material law of Belgium except its choice of lawprinciples and the United Nations Convention on Contracts for the International Sale ofGoods of April 11, 1980 and the exclusive venue of any dispute relating to the GeneralSales Conditions or the transactions contemplated herein shall be the Courts of Aalst.

14. Anti-boycott legislation

Any agreement referring to the General Sales Conditions in conflict with US anti-boycottor any other applicable anti-boycott legislation shall be resolved first by doing thenecessary to conform with the applicable anti-boycott provisions, including, not limited to,amending such agreement and, if that does not resolve the conflict, the violatingagreement shall be null and void as if it had never come into existence.

15. Severability

Should any part, term or provision of the General Sales Conditions be declared by anycourt to be or be accepted by the parties as being in conflict with the law orunenforceable the validity and enforceability of the remainder of the General SalesConditions shall not be affected thereby. The offending part or provision shall be replacedby an enforceable and valid part or provision of which the economic intent is as far aspossible the same.

BECTON DICKINSON INTERNATIONALBranch of BECTON DICKINSON B.V. ("BDI")

POB 13Erembodegem Dorp 86

9320 - Erembodegem (Belgium)

GENERAL SALES CONDITIONS

Page 121: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

126 Annex

BD VialonTM

BD VialonTM - Clinically proven� Increases ease of penetration1.

� Reduces the risk of infiltration2.

� Reduces risk of phlebitis and increasing indwell times,thereby reducing costs1,3,4,5.

� Exhibits greater kink resistance ensuring consistent flowrates1,3.

� Superior kink recovery6.

Other benefitsn Reduces need for I.V. resiting due to reduced

complications.

n Reduces the total I.V. therapy cost due to problem-freelonger indwell times.

n Precise cannula geometry and tipping contributes to easeof insertion.

Products manufactured in BD VialonTM

� BD VenflonTM Pro

� BD Saf-T-IntimaTM

� BD InsyteTM

� BD InsyteTM AutoguardTM

� BD InsyteTM Autoguard-WTM

� BD Insyte-NTM

� BD Insyte-NTM AutoguardTM

References:

1 Gaukroger P.B., Roberts GJ.G.. Manners T.A.; Infusionthrombophlebitis: A prospective comparison of 645 VialonTM

and Teflon® cannulae in anaesthetic and post-operative use.Anaesth. Intens. Care (1988) 16:265-271

2 Stanley M.D., Meister E., Fuschuber K.; Infiltration DuringIntravenous Therapy in Neonates: Comparison of Teflon® andVialonTM Catheters.Southern Medical Journal 85 (9) Sept. 1992,883-886

3 Jaquot C., Fauvage B., Bru J.P., Croize J., Calop J.; Effect ofMaterial on Thrombophlebitis Risk with Peripheral VenousCatheters.

Ann Fr Anestha Reanim 1989:8:3-7 (English abstract)

4 Maki D.G., Ringer M.; Risk Factors for Infusion-Related Phlebitiswith Small Peripheral Venous Catheters.Annals of Internal Medicine 114(10) May 1991, 845-851

5 McKee J.M., Shell J.A., Warren T.A., Campbell V.P.;Complications of Intravenous Therapy: A RandomizedProspective Study - VialonTM vs. Teflon®

Journal of Intravenous Nursing 12(5) Sept. 1989, 288-2956 Data on file

Page 122: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Annex 127

Cannulae / Catheter Conversions

Outer Diameters / Gauge-French Sizes

The definition of gauge measurement comes from the AAMI (Association for theAdvancement of Medical Instrumentation - USA). This states how many cannulae fitinto a tube with an inner diameter of 1” (1 inch = 25.4 mm).

The AAMI uses only even numbers (18, 20, 22, etc.) as measuring units.A similar measurement definition exists in Great Britain and this is knownas the SWG (Standard Wire Gauge). The SWG uses consecutivenumbers, ie 13 to 24 and is the more common method of measurementfor catheters in Europe.The Charriere, commonly known as French, relates directly to thecatheter size, i.e. 1 Ch = 0.33 mm.In the following tables the measurements of the AAMI - SWG - Frenchare shown in relation to the outer ø in mm.

1 inch

BD’s multi lumen catheter(BD Careflow™) hub colourcoding differentiates the lumensand not the catheter gauge, i.e.

white proximalbrown tipblue middle

1.80

1.45 1.19 1.17 0.94

0.910.69

0.660.58

1.91

2.31

AAMI

1.50

SWG

14G

16G18G 20G

22G24G

13G

14G

15G

16G17G 18G

19G

20G

21G22G

23G24G

2.48

92.

184

1.93

0

1.7271.524 1.321 1.118

0.965

0.8640.763

0.6600.584

0.533

TableSWG - AAMIOuter Ø mm

BD Cannulae/Catheter Conversions

Outsidediameter ofcatheter in mm

Range ofactual outsidediameter inmm

Color 1) 2) Gauge 3)

0,6

0,7

0,8; 0,9

1,0; 1,1

1,2; 1,3

1,4; 1,5

1,6; 1,7; 1,8

1,9; 2,0; 2,1; 2,2

2,3; 2,4; 2,5

2,6; 2,7; 2,8

3,3; 3,4

0,550 to 0,649

0,650 to 0,749

0,750 to 0,949

0,950 to 1,149

1,150 to 1,349

1,350 to 1,549

1,550 to 1,849

1,850 to 2,249

2,250 to 2,549

2,550 to 2,849

3,250 to 3,549

26

24

22

20

18

17

16

14

13

12

10

1) The color may be opaque or translucent.2) The color coding is usually applied to the catheter hub or to an integralfitting.3) The use of gauge numbers is optional.

Color coding andcorresponding sizes of catheter

Page 123: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

IND

EX

Page 124: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

130 Index

Numerical Index

300013 20300014 20300015 20300026 20300094 16300136 21300137 21300138 21300139 21300185 19300187 19300188 19300189 19300190 19300296 18300300 16300318 18300320 18300321 18300322 18300323 18300330 18300334 20300400 16300479 7, 27300506 18300512 18300513 18300516 18300600 16300605 21300613 21300626 18300629 21300635 16300637 16300700 16300779 17300780 17300800 16300865 21300866 21300867 21300869 21300900 16300910 19300911 19300912 19300928 18301000 16301001 18301155 16301156 16301190 21301229 21301231 21301300 16301355 20301500 16

301504 18301700 16301750 16301792 9, 32301793 9, 32301889 9, 32301860 9, 32301865 9, 32301887 9, 32301888 9, 32301900 16302187 19302188 19302200 16302434 7, 27302467 9, 31302468 9, 31302469 9, 31302478 9, 31302607 8, 30302639 9, 31302640 8, 29302641 8, 30302642 8, 29302643 8, 30302644 8, 30302645 8, 30302650 8, 29302654 8, 29302655 8, 29302656 8, 30302657 8, 30302658 8, 29302672 8, 30302673 9, 31302674 9, 31302678 8, 30302679 9, 31302680 9, 31302682 9, 31302683 8, 30302684 8, 30302685 9, 31302686 9, 31302688 9, 31302690 8, 29302692 8, 29302695 8, 29302696 8, 29302704 8, 30302707 8, 30302708 8, 30302709 8, 30302711 8, 30302712 9, 31302713 9, 31302715 9, 31302718 8, 30302721 8, 30

302729 8, 30302742 8, 30302761 8, 29302758 8, 29302773 9, 31302775 9, 31303212 9, 32303328 61303370 61303376 61303377 61303379 61303800 16304000 16304100 16304300 16304432 16304434 16304622 16304727 16304827 16305180 7, 17305207 22305208 22305209 22305210 22305211 7, 17305217 22305218 22305219 22305220 22305250 7, 27305251 7, 27305252 7, 27305253 7, 27305254 7, 27305255 7, 27305269 6, 26305270 6, 26305271 6, 26305272 6, 26305273 6, 26305274 6, 26305275 6, 26305277 6, 26305278 6, 26305279 6, 26305282 6, 26305283 6, 26305298 6, 26305307 9, 33305309 9, 33305310 6, 26305311 6, 26305312 6, 26305313 6, 26305501 20305502 20305624 7, 27

305625 7, 27305626 7, 27305627 7, 27305636 7, 27305637 7, 27305645 7, 27305710 7, 27305760 6, 24305770 6, 24305771 6, 24305781 6, 24305782 6, 24305783 6, 24305784 6, 24305785 6, 24305786 6, 24305789 6, 24305833 6, 26305892 6, 24305894 6, 24305895 6, 24305899 6, 24305904 6, 25305905 6, 25305907 6, 25305908 6, 25305909 6, 25305945 6, 25305946 6, 25305964 7, 27305968 7, 27305970 7, 27306554 7, 23306555 7, 23306556 7, 23306570 7, 23306571 7, 23306572 7, 23308027 19308062 19308063 19309050 18309110 18309628 20320480 37320516 37320517 37320518 37320519 37320590 37320829 36320909 36320910 36320911 36320921 36320929 36320930 36320931 36320932 36

Page 125: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Index 131

Numerical Index

320933 36320935 36371167 120371607 120372057 120373460 119371901 120377477 120378542 118381112 43381123 43381134 43381137 43381144 43381147 43381154 43381157 43381164 43381167 43381211 47381212 44381223 44381234 44381237 44381244 44381246 44381257 44381267 44381311 47381312 44381323 44381334 44381337 44381344 44381346 44381357 44381411 12, 48381412 12, 45381423 12, 45381434 12, 45381437 12, 45381444 12, 45381447 12, 45381457 12, 45381467 12, 45381511 12, 48381512 12, 45381523 12, 43381534 12, 45381537 12, 45381544 12, 45381547 12, 45381557 12, 45381812 12, 45381823 12, 45381834 12, 45381844 12, 45381912 12, 45381923 12, 45

381934 12, 45381944 12, 45382258 43382259 43382268 43382269 43382277 43382287 43383211 49383213 49383221 49383223 49383234 49383236 49383244 49383246 49383312 12, 50383313 12, 50383322 12, 50383323 12, 50383335 12, 50383336 12, 50383346 12, 50383600 12, 51383601 12, 51383602 12, 51383605 12, 51383606 12, 51383607 12, 51383608 12, 51383609 12, 51383620 13, 52383621 13, 52383622 13, 52383625 13, 52383626 13, 52383627 13, 52383628 13, 52383629 13, 52383630 12, 52383631 12, 52383632 12, 52383635 12, 52383636 12, 52383637 12, 52383638 12, 52383639 12, 52383640 12, 51383641 12, 51383642 12, 51383646 12, 51383647 12, 51383648 12, 51383649 12, 51383650 12, 51383660 13, 52383661 13, 52383662 13, 52383666 13, 52

383667 13, 52383668 13, 52383669 13, 52383670 13, 52383680 12, 52383681 12, 52383682 12, 52383686 12, 52383687 12, 52383688 12, 52383689 12, 52383690 12, 52384030 59384040 59384050 59384156 59384157 59384158 59384159 59384331 59384341 59385100 13, 53385101 13, 53385102 13, 53385108 13, 54385161 13, 54385162 13, 54385163 13, 54385164 13, 54385300 13, 55385301 13, 55385303 13, 55385305 13, 55385306 13, 55385308 13, 55385324 13, 55391349 46391350 46391451 40391452 40391453 40391454 40391455 40391456 40391457 40392015 62392020 62393202 41393204 41393206 41393207 41393208 41393209 41393210 41393222 12, 42393224 12, 42393226 12, 42393227 12, 42393228 12, 42

393229 12, 42393230 12, 41394074 60394075 60394080 60394090 60394181 63394187 57394188 57394251 40, 41394252 40, 41394253 40, 41394254 40, 41394255 40, 41394256 40, 41394257 40, 41394280 44394281 44394282 44394283 44394284 44394285 44394286 44394501 13, 54394600 56394601 56394602 56394605 56394630 58394633 58394636 58394637 58394638 58394653 58394656 58394657 58394658 58394926 56394936 56394945 56394951 56394961 56394971 56394982 57394983 57394995 56394997 56396350 60396352 60396353 60396363 60396373 60397201 56397015 63397251 56397400 56397509 56397590 56397608 56

Page 126: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

132 Index

Numerical Index

402062 70402064 70402065 70402066 70402067 70402076 71405018 75405028 75405056 73405057 73405065 68405068 68405069 68405075 66405076 66405084 68405090 72405092 75405104 66405110 66405111 66405112 66405113 66405148 68405149 68405185 75405186 75405188 75405190 75405191 75405193 75405194 75405211 68405234 68405240 67405243 68405244 67405245 68405246 67405247 67405248 67405249 67405250 67405251 67405252 67405253 67405254 67405255 67405256 67405257 67405258 67405259 67405260 66, 68405261 66, 68405262 77405291 71405292 71408263 77408264 77

408265 77408266 77408267 77408268 76408269 76408270 79408273 79408275 79408289 78408348 75408360 68408627 77409442 66409443 66680000 96680006 96680077 95680078 95680080 95680081 95680082 95680084 95680088 95680089 95680093 95680098 95680099 95680100 95680102 95680104 95680106 95680124 94680126 94680128 94680136 94680140 94680178 96680331 96680333 95680334 95680336 95680337 94680338 94680339 94680340 94680342 96681000 83681002 83681004 83681006 83681011 84681014 84681033 82681150 91681151 91681152 91681153 91681154 91681155 91

681156 91681157 91681158 91681159 91681161 91681612 86681614 85681615 86681616 87681618 88681619 87681620 88681622 86681623 85681624 86681625 86681626 87681627 87681628 87681629 88681630 88681631 93681633 86681634 86681638 86681639 85681640 85681642 93681643 85681644 85681646 93681647 86681648 93681649 85681650 85681652 87681653 87681655 87681656 87681658 86681660 86681662 86681664 86681666 86681669 85681670 85681672 85681673 85681678 86681679 86681682 87681683 87681686 87681687 87681690 88681691 88681694 88681695 88681698 86

681699 86681701 86681702 87681703 87681706 85681707 85681709 85681710 85681713 87681714 87681717 87681718 87681720 88681721 88681724 88681725 88681728 88681729 88681731 89681732 89681733 89681734 89681735 90681736 90681737 90681738 90681740 83681741 83681742 83681743 83681746 82681748 86681749 85681750 93681751 93681752 87681753 86681754 87681755 87681756 87681757 88681758 88681759 88681760 86682001 100682002 100682004 100682005 100682006 100682008 100682009 100682010 100682011 100682013 100682017 100682018 98682019 98682021 98682022 100

Page 127: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Index 133

Numerical Index

681741 83681742 83681743 83681746 82681748 86681749 85681750 93681751 93681752 87681753 86681754 87681755 87681756 87681757 88681758 88681759 88681760 86682001 100682002 100682004 100682005 100682006 100682008 100682009 100682010 100682011 100682013 100682017 100682018 98682019 98682021 98682022 100682025 100682027 101682030 100682032 100682037 100682041 100682046 100682051 101682052 101682053 101682054 101682055 101682056 101682058 102682059 102682060 102682061 102682063 102682065 102682079 104682084 102682089 102682093 104682103 102682155 96682158 101682159 99, 101

682161 96682185 104682186 104682189 104682190 104682191 104682192 104682193 104682194 104682226 104682229 104682230 104682232 104682234 104682236 104682237 104682245 92682263 103682264 103682266 103682274 104682275 104682287 100682288 100682289 100682290 100682291 100682292 98682293 100682294 100682295 100682296 102682298 104682301 101682303 101684000 102684001 102684002 104684003 104684004 96684056 114684059 114684062 115684063 113684078 108684081 108684082 109684084 108684085 108684086 109684087 112684090 108684091 112684096 108684102 109684104 109684109 110684119 113684121 110

684128 109684129 110684134 110684138 109684138 113684139 113684147 113684150 114684167 110684175 110684178 111684179 114684181 111684188 112684200 114684204 111684216 114684227 111684236 111684242 111684243 112684256 102684260 112685171 104685185 104685190 104686619 104686337 99686340 99686495 99686496 99686562 99686572 99686585 99686714 99686715 99

Page 128: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Index

Alphabetical Index

134

AAdjustable BD Durasafe Plus™ 73Amplatz™ Needle 79Angiocath™ 43Arterial Angiograph needles 79Arterial Cannula 92Arterial Catheters 92, 93Arterial Needle 79Auto-disable syringes 32

BBard-Parker™ Heimlich chest drain valve 119Biopsy needle for bone marrow biopsy 77Biopsy needles 77Blunt Fill needle 4, 7, 17Bonnano™ 78

CCables Index 106Careflow™ Arterial Catheters 93Careflow™ Single Lumen 85Careflow™ Single Lumen Catheter Sets 86Careflow™ Double Lumen Catheter Sets 87Careflow™ Triple Lumen Catheter Sets 88Careflow™ Quad Lumen Catheter Sets 89Careflow™ Quint Lumen Catheter Sets 90Central Venous Catheters 83-91Chiba Needles 76Clear Oral Syringes 22Closed IV Catheter System 51, 52Closed, needleless IV Access devices 55Closed, needleless IV Infusion System 61Colour Coding Pegs 57Combi Plug Male/Female 60Combined spinal/epidural anaesthesia sets 72, 73, 74Connecta™ Extension Tubing 56Connecta™ Extension Tubing for syringe pumps 56Connecta™ Micro stopcocks 57Connecta™ Multiflo™ infusion manifold 58Connecta™ Multiflo™ pole holder 58Connecta™ PE Pressure Monitoring Lines 104Connecta™ single stopcocks 56Connecta™ stopcocks with Extension 56Criticath™ 95Critikit™ 96Critiflow™ flush device 102

DDiscardit™ 18Disposal Systems 4, 7, 27Disposable Domes and Accessories 102Disposable Domes for RT2000 103Disposable Transducers 97-101Durasafe Plus™ 72, 74DTXPlus™ Disposable Pressure Transducers 97, 98DTXPlus™ Flexi Transducer System 99

EEclipse™ 4, 6, 24

Epidural Products 69, 70, 71Epidural Products - Individual Components 71Exacta™ 94E-Z Scrub™ 120

FFemoral Artery Set 93Fill Needles 7, 17First Midcath™ 59First PICC™ 59Flopro™ 63Floswitch™ 82Fluid Connectors 53, 54, 55

GGabarith™ Disposable Tranducer Sets 100Gabarith™ test 97

HHigh Capacity Syringes 21Hub Cutter 5, 9, 33Hydrocath Assure™ 91Hypodermic Needles 16

IIce/Room Temperature Injectate Systems 96Infusion Accessories 60Infusion Manifold 58Infusion Sets 60Insulin Syringes 36Insyte-N™ 47Insyte-N™ Autoguard™ 10, 12, 48Insyte™ 44Insyte™ Autoguard™ 10, 12, 45Insyte™ Autoguard™ Winged 10, 12, 45Insyte-W™ 44Integra™ 4, 6, 26Interlink™ 61Intima™ 49Intima™ Y 49Intradiscal Needles 76Introducers 66Introducers for fine spinal needles 68Introsyte™ 59IV Catheter with integrated Infusion Set 49IV Catheters 40, 41, 43, 44, 46, 47IV Dressing 62

LLeVeen 118Local/Regional anaesthesia needles 75Lock CSE Sets 74Long length spinal needles 68Luer-Lok™ Plug 60

MMicro-Fine™ Plus Insulin syringes 36Micro-Fine™ Plus Pen needles 37

Page 129: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

Index

Alphabetical Index

135

Microlance™ 16Mini-Perisafe™ Plus 69Multiflo™ 3 58Multiflo™ 5 58

NNeoflon™ 46Neonatal catheters 46, 47, 48Nexiva™ 10, 12, 13, 51, 52Nokor™ Admix Needles 17

OOpaque oral syringes 22Oral Syringes 22

PPaediatric catheters 46, 47, 48Paediatric spinal needles 68Pen needles 37Percutaneous Sheath Introducers 94Perisafe™ Plus 69Perisafe™ 70Peritoneo Venous Shunt 118Pheripherally inserted central catheters 59Pheripherally inserted midline catheters 59Plastipak™ 1 ml 20Plastipak™ 2,3,5,10 ml 19Plastipak™ 20, 30, 50, 100 ml 21Posiflow™ 11, 13, 55Potts-Cournand Needle 79Precision syringes 20Prefilled flushing devices 23Pressure Lines 104Pressure Accessories 104Pressure Transducer Sets 97-104Protection cap for Luer syringe 60Pulmory Artery and Thermodilution Catheters 95Pulmory Percutaneous Sheath Introducer Sets 94

QQ-Syte™ 11, 13, 53, 54

RRadial artery set 93Regional Block needle 75RT2000 Reusable Transducer 103Reusable Pressure Transducers 102Re-use prevention 28-33Re-use prevention syringes 29-32Rubber membrane Luer Lok™ plug 60

SSafedraw™ Safe Arterial Blood Sampling 101Safety IV Catheter with integrated Infusion Set 50Safety IV catheters 42, 45, 48,Safety needles 24Safety needles and syringes 25Safety neonatal catheters 48Safety paediatric catheters 48

Safety syringes 26SafetyGlide™ 4, 6, 25Saf-T-Intima™ 10, 12, 50Saf-T-Intima™ Y 10, 12, 50Saline SP 4, 7, 23Saline XS 4, 7, 23Scrub brushes/Sponges 120Secalon-T™ 83Secalon™ Seldy 84Sharps Disposal Systems 4, 7, 27SoloMed™ 2pc 5, 8, 29SoloMed™ 3pc 5, 8, 30SoloMed™ 3pc with Safety Needle Shield 5, 9, 31SoloShot™ IX 5, 9, 32SoloShot™ LX 5, 9, 32Spinal Anaesthesia 66, 67, 68Spinal needle sets for local anaesthesia 68Spinal Needles Quincke Type point 67, 68Stopcocks 56, 57Suprapubic catheter 78Syringes with breakable plunger 5, 8, 9, 29, 30, 31

T2-piece syringes 183-piece syringes 19Transfer needle 63Transducer Interface Cables 105-115Transducer Interface Cables - Guide to terminology107Tuohy-Borst adapter 94Tuohy Epidural needle 75Tuohy Weiss Epidural needle 75

UUniversal Fell Needles 17

VVeca-C™ 62Veca-Fix™ 62Venaguide™ Seldinger wire 85-91, 94Venflon™ 40Venflon™ Pro 41Venflon™ Pro Safety 10, 12, 42Vialon™ 128

WWestcott Biopsy needle 77Whitacre Pencil Point Spinal Needles 66Withdrawal cannula 63

XXCaliber™ 104

Page 130: 1415 BD Produktkatalog - Diamed EMA_Product_Catalogu… · 6 InjectionSystems Description NeedleDimensions Boxcontent Itemnumber units 1ml 27G1/ 2"-0.4x13mm 50 305789 3ml 25G5/ 8"-0.5x16mm

BD, BD Logo and all other trademarks (unless noted otherwise) are the property of Becton, Dickinson and Company. ©2007 BD

BD in GermanyTullastrasse 8-1269126 HeidelbergGermanyTel: +49 6221 305 374Fax: +49 6221 305 398

BD in United Arab EmiratesArif & Bintoak Building1st floorKarama, Zabeel RoadDubaiUnited Arab EmiratesTel: +971 43 379 525Fax: +971 43 379 551

BD in KenyaAfrica Re-CenterHospital Road, Upper HillPO Box 76613Nairobi 00508KenyaTel: +254 2 02 738 339Fax: +254 2 02 738 342

BD in PolandKrolowej Marysienki 9002-954 WarsawPolandTel:+48 2 26 517 588Fax:+48 2 26 517 589

BD in Russia7th Floor, Block C,18, Krasnopresnenskaya nab.123317 MoscowRussiaTel:+7 495 7 758 582Fax:+7 495 7 758 583

BD in South AfricaThe Woodlands Office ParkBuilding 12, 2nd FloorWoodlands Drive, WoodmeadPO Box 3569, Rivonia 21282199 JohannesburgRepublic of South AfricaTel:+27 11 603 2620Fax:+27 11 804 0544

BD in TurkeyBüyükdere Cad. Üçyol MevkiiNoramin Is Merkezi No:55 K:1/10534398 Maslak/ IstanbulTurkeyTel:+9 02123 282 720Fax:+9 02123 282 730