    Dr.ZX

    Operation Manual

    Hitachi Construction Machinery Co. Ltd.

    © 2004 Hitachi Construct ion Machinery Co., Ltd. All rights reserved

  • 8/18/2019 140396314-Dr-ZX

    2/192

    EPVC_LargeDiagnostic / Monitoring / Adjusting tools for foll owing excavators. 

    Hitachi EX-1 (550), EX-3 (400 to 600), EX-5 (400 to 800), ZAXIS (450 to 850) 

    Fiat Hitachi FH450-3, EX455, EX456

    EPVC_MidDiagnostic / Monitoring / Adjusting tools for foll owing excavators. 

    Hitachi EX-1 (USE ser ies), EX-2 (60 to 300), EX-3 (60 to 310) EX-5 (60 to 370), ZAXIS (70 to 380) Fiat Hitachi FH-2 series, FH-3 series, EX series (less than 40 tons)

    EPVC_MiniDiagnostic / Monitoring / Adjusting tools for foll owing excavators. 

    Hitachi EX33Mu & EX58Mu 

    HMS_LargeMidMonitoring data download / Data logger setting foll owing excavators . 

    Hitachi ZAXIS (70 to 850)

    John Deere C series (80C to 800C)

    MIC_MiningMonitoring data download / Data logger setting / Monito ring / Diagnostic following excavators. 

    Hitachi EX1200-5/5C, EX1900-5, EX2500-1/5, EX3500-1/2/3, EX3600-5, EX5500-5

  • 8/18/2019 140396314-Dr-ZX

    3/192

     

    EPVC_LARGE

    Operation Manual

    Hitachi Construct ion Machinery Co. Ltd. 

    NOTE

    This manual is based on Hitachi ZX series. Screen / Function /

    Procedure are vary by model.

  • 8/18/2019 140396314-Dr-ZX

    4/192

     

    1. Necessary Tools & Cable Connection

    2. MODE

    OPERATION MODE

    3. Operation Mode – How to Start Dr.ZX with Operation Mode

    4. Operation Mode – Self-Diagnosti c

    5. Operation Mode – Monitor ing

    6. Operation Mode – Special Funct ion (WU Deactivation)

    7. Operation Mode – Special Func tion (ECO Deactivation)8. Operation Mode – Special Function (Pump Adjus tment)

     

    SERVICE MODE

    9. Service Mode – How to Start Dr.ZX with Service Mode

    10. Service Mode – Learning Data Display

    11. Service Mode – Monitor Panel LCD Control

    12. Service Mode – Parameter Change

    13. Service Mode – Act/Deact of Parameters

     

    STAND ALONE MODE

    14. Stand Alone Mode - How to Start Dr.ZX with Stand Alone Mode

    15. Stand Alone Mode – Change Password

    16. Stand Alone Mode – View Manuals17. Stand Alone Mode – Play Recorded Data

     

  • 8/18/2019 140396314-Dr-ZX

    5/192

    1. Necessary Tools & Cable Connection

    Cable connection

    (a) Palm OS PDA (b) Serial cable (c) Dr.ZX communication cable

    Dr.ZX must be ins talled. Hitachi

    recommends following models.

    SONY

    Clie PEG-TJ25

    PalmOne Inc.m125 / 130 / 500 / 505 / 515

    Tungsten T2 / T3 / C

    For SONY Clie PEG-TJ25

    Purchase from CPD. P/no. is

    4629330 (Hitachi unique

    parts).

    For PalmOne PDAsPurchase from local market.

    Product name is HotSync serial

    This is Hitachi unique part. Make an

    order to your parts ordering channel.

    Hitachi part no. is 4476512.

    Dr.ZX cable Serial cable Palm OS PDA Palm

    Serial cable

    Dr.ZX cable

    Equipment

    Connect to

    Dr.ZX

    connector.

    Necessary tools

  • 8/18/2019 140396314-Dr-ZX

    6/192

    2. Mode

    Start Dr.ZX with

    Operation Mode 

    Self-Diagnostic

    Monitoring / Recording Sensor out-put signal

    WU (Warming-up function) Deactivation

    ECO (Economy function) Deactivation

    Pump (Angle sensor) Adjustment

    Start Dr.ZX with

    Service Mode.

    Check Engine Learning Data

    Monitor Engine Speed & Hydraulic Oil Temperature

    Change Parameter(s), such as follows

    Engine RPM Auto-Lub. Interval

    Pump Max. Displacement

    Pump Max. Torque

    Pump Cut-off Pressure

     Activate or Deactivate Changed Parameters

    Change Password

    Replay Recorded Monitoring Data

    Refer Instant Operation Manual

    EPVC_Large

    NOTE

    For non-current models (such

    as EX-2/-3/-5), operation &

    stand-alone mode will apply

    Stand-alone

    Mode (No need

    to hock up with

    equipment)

  • 8/18/2019 140396314-Dr-ZX

    7/192

    3. Operation Mode – How to Start Dr.ZX with Operation Mode (1/4)

    Turn key switch

    “OFF”.

    Check engine

    learning switch is

    OFF.

    Connect Dr.ZX to

    equipment.

    Turn key switch

    “ON”.

    Start Dr.ZX. Select

    “EPVC_Large”.

    Start operation

    mode.

    Special Function

    Monitoring

    View / Recording

    Self - DiagnosticOperation mode

    menu.

    Switch on Palm. 

  • 8/18/2019 140396314-Dr-ZX

    8/192

    3. Operation Mode – How to Start Dr.ZX with Operation Mode (2/4) 

    (b) Check Engine learning swi tch i s OFF

    OFF

    Stamp

    (a) Turn key swit ch “ OFF”

    Fuse box

      (c) Connect Dr.ZX to equipment.

  • 8/18/2019 140396314-Dr-ZX

    9/192

    3. Operation Mode – How to Start Dr.ZX with Operation Mode (3/4) 

    (d) Turn key switch “ ON”

    Main switch is vary by Palm model.

     Above shows Palm m500 / 505 / 515.

    (f) Start Dr.ZX(e) Switch “ ON” Palm

    Tap “Dr.ZX” icon on Palm.

    Check model. If model is correct, tap

    “correct”, if not tap “ESC” and contact

    to your dealer.

    Tap “START”.Tap “ ” of EPVC_Large.

    (h) Start operation mode (i) Model / Version information(g) Select “ EPVC_Large” .

  • 8/18/2019 140396314-Dr-ZX

    10/192

    3. Operation Mode – How to Start Dr.ZX with Operation Mode (4/4) 

    (j) Operation mode main menu

  • 8/18/2019 140396314-Dr-ZX

    11/192

    4. Operation Mode – Self-Diagnostic (1/3) 

    Select

    “Self-diagnostic”.

    No error

    detected.

    Message will

    display.

    Start Dr.ZX with

    Operation mode.

    Error(s) are

    detected.

    Tap “Details” for

    check detail of

    each error code.

    Error code(s) will

    display.

    Tap “ESC”. Carry out

    “Retry”.

    Still error(s) are

    detected

    No error 

    detected.

    Message will

    display.

    Error code(s) will

    display.

  • 8/18/2019 140396314-Dr-ZX

    12/192

    4. Operation Mode – Self-Diagnostic (2/3) 

    If Dr.ZX could not detect any error(s),

    above message will display. Tap

    “ESC”.

    Tap “Retry B” for retrying.Error code(s) that detected will

    display to Palm. Tap “ESC” for retry.

    If Dr.ZX could not detect any error(s),

    above message will display. Tap

    “ESC”.

    Tap “ ” of Self-Diagnostic.

    (a) Start self-diagnos tic

    (d) Retry(c) Error(s) detected (e) No error detected

    (b) No error detected

  • 8/18/2019 140396314-Dr-ZX

    13/192

    4. Operation Mode – Self-Diagnostic (3/3) 

    Tap “ESC” fir quit self-diagnostic.Message will show meanings of each

    code, and corrective action. Tap

    “Next” for view additional information

    or other code.

    If Dr.ZX still detect any error(s) , error 

    code(s) will display. Tap “Details” for 

    check error(s).

    (f) Still error(s) detected (g) Explanation of each code

    NOTE

    Refer service manuals for 

    troubleshooting.

    (h) Explanation of each code

  • 8/18/2019 140396314-Dr-ZX

    14/192

    5. Operation Mode – Monitoring (1/5) 

    Select Monitor

    display.

    Enter model

    code & serial no.

    Select item.

    (Max. four items)

    Start monitoring.

    Write recorded

    data to data

    bank.

    Start recording. If data bank isn’t

    empty, Dr.ZX will

    ask overwrite.

    Enter comment if

    you want.

    Select data bank

    that store

    recorded data.

    Operation mode

    menu.

    NOTE

    If you did not enter model code & equipment

    serial no., you can’t record monitori ng data to

    Palm.

  • 8/18/2019 140396314-Dr-ZX

    15/192

    5. Operation Mode – Monitoring (2/5) 

    (a) Start Monitoring

    Tap “ ” of Monitor Display

    (b) Enter model code & s/no.

    Tap columns and enter model code &

    serial no. If you did not enter model

    code & serial no., you can’t record

    monitoring data.

    TIP

    You can use keyboard to enter 

    model code & serial no. by tap

    “abc” or “123” on GRAFFITI area.

    Selected item

    Number of

    selected item(s).Clear selected

    item(s).

    Item

    changeover

    button

    (c) Tap “ OK”

     After enter model & serial no., tap

    “OK”. If you don’t need to record

    monitoring data, no need to enter 

    model code & serial no. Just tap “OK”.

    Tap “ ” of item you want monitor. You

    can monitor four items in once.

    (d) Select monitoring item(s)

  • 8/18/2019 140396314-Dr-ZX

    16/192

    5. Operation Mode – Monitoring (3/5) 

    (h) Recording

    (e) Start display data

     After selecting item(s), tap “Start” for 

    display monitoring data.

    Item(s) will display. Screen will vary

    by selected items. Tap “Hold” for 

    pause data. If you want quit, tap

    “ESC”.

    (g) Start Recording

    Tap “Record” for record monitoring

    data. Dr.ZX will record data for three

    (3) seconds.

    During recording, above screen will

    display.

    NOTE

    If you did not enter 

    model code & serial no.,

    “Record” but ton shal l

    not appear.

    (f) Start display monitoring data

  • 8/18/2019 140396314-Dr-ZX

    17/192

    5. Operation Mode – Monitoring (4/5) 

    (k) Data bank is empty

    If selected data bank is empty, above

    screen will display. Tap “Write” for 

    store recorded monitoring data.

    (l) Confirmation

     After data stored, confirmation screen

    will display. Tap “ESC” to quit, or if 

    you want enter comment, tap

    “Comment”.

    (l) Enter comment

    Tap comment column, and enter 

    comment. After entering, tap “OK”.

    TIP

    You can use keyboard to enter 

    comment. Tap “abc” on GRAFFITI

    are.

    (i) Select data bank

    Tap data bank (figure) that you want

    to store recorded data.

    If selected data bank already has

    data, above screen will appear. Tap

    “OverWrite” for store recorded data,

    tap “ESC” for back to previous menu.

    (j) Data bank is not empty

    NOTE

    Click here for how to repaly

    recorded data.

  • 8/18/2019 140396314-Dr-ZX

    18/192

    5. Operation Mode – Monitoring (5/5) 

    Items can be moni tored (vary by model)

  • 8/18/2019 140396314-Dr-ZX

    19/192

    6. Operation Mode – Special Function (WU Deactivation –1/2) 

    Select Special

    Function.

    Select WU

    Deactivation

    WU has

    deactivated.

    ExecuteSpecial function

    menu

    WU Function.

    WU stands for Warming-Up. This function is, when start engine while hydraulic oil

    temperature is less than zero (0) Celsius, computer will increase low idle rpm for warm

    hydraulic oil qu ickly.

  • 8/18/2019 140396314-Dr-ZX

    20/192

    6. Operation Mode – Special Function (WU Deactivation –2/2) 

    (a) Select special func tion

    Tap “ ” of Special Function.

    (b) Select WU deactivation

    Tap “ ” of WU Deactivation.. Tap “Execute for Deactivation. If you

    want back to previous menu, tap

    “ESC”.

    (d) Confirmation

     After deactivation, above message

    will display. Tap ”ESC” for quit.

    NOTE

    WU (Warming-up function) will

    re-activate when key switch is

    turned “ OFF”.

    (c) Select WU deactivation

  • 8/18/2019 140396314-Dr-ZX

    21/192

    7. Operation Mode – Special Function (ECO Deactivation –1/2) 

    Select Special

    Function.

    Select ECO

    Deactivation

    ECO has

    deactivated.

    ExecuteSpecial function

    menu

    ECO Funct ion

    ECO stands for ECOnomy. This function is, when all levers are in neutral position,

    computer wi ll reduce engine rpm to 1600min-1 gradually. If any lever(s) are operated, engine

    rpm will back. 

  • 8/18/2019 140396314-Dr-ZX

    22/192

    7. Operation Mode – Special Function (ECO Deactivation –2/2) 

    (a) Select special func tion

    Tap “ ” of Special Function.

    (b) Select ECO deactivation

    Tap “ ” of ECO Deactivation.. Tap “Execute for Deactivation. If you

    want back to previous menu, tap

    “ESC”.

    (d) Confirmation

     After deactivation, above message

    will display. Tap ”ESC” for quit.

    NOTE

    ECO (Economy function) will

    re-activate when key switch is

    turned “ OFF”.

    (c) Select WU deactivation

  • 8/18/2019 140396314-Dr-ZX

    23/192

    8. Operation Mode – Special Function (Pump Adjustment –1/9) 

    Turn key switch

    “OFF”.

    Check engine

    learning switch is

    OFF.

    Connect Dr.ZX to

    equipment.

    Start engine. Switch on Palm. Start Dr.ZX.Confirm engine

    is running with

    low idle.

    Start operation

    mode.

    Operation mode

    menu.

    Switch OFF

    Palm.

    Remove both

    angle sensors

    from pump.

    Start

    “EPVC_Large”.

    Confirm sensors

    are connecting to

    harness.

    Continue to next page.

     

  • 8/18/2019 140396314-Dr-ZX

    24/192

    8. Operation Mode – Special Function (Pump Adjustment –2/9) 

    Select “Max.

    Disp. Holding”.

    Tighten bolts &

    washers.

     Adjust sensor

    shaft.

    Wait more than

    five (5) seconds.

     Adjust angle

    sensors.

    Install angle

    sensors to pump.

    Select “Special

    Function”.

     Apply a film of 

    grease.

    From

  • 8/18/2019 140396314-Dr-ZX

    25/192

    8. Operation Mode – Special Function (Pump Adjustment –3/9) 

    (a) Switch o ff Palm (b) Turn key switch off

    Main switch is vary by Palm model.

     Above shows Palm m500 / 505 / 515.

     

    Pump-2

    sensor 

    Pump-1

    sensor

    Pump-2

    sensor 

    Loose

    Bolts

    (c) Remove A (angle) sensors f rom pump

    Remove two (2) angle sensors from

    pump. When removing, take care not

    to lose internal spacer & fastener 

    spring.

    Engine

    Pump-1

    sensor

    ZX450 & ZX500 ZX600 & ZX800

  • 8/18/2019 140396314-Dr-ZX

    26/192

    8. Operation Mode – Special Function (Pump Adjustment –4/9) 

    Confirm sensors are connecting to

    harness.

    (d) Confirm connection

    OFF

    Fuse box

    (e) Check Engine learning sw itch is OFF

    Connect to

    harness

    Stamp

     

    (f) Confi rm Dr.ZX is connecting to equipment.

  • 8/18/2019 140396314-Dr-ZX

    27/192

    8. Operation Mode – Special Function (Pump Adjustment –5/9) 

    (g) Start engine (h) Run engine at low idle

    Confirm engine control dial position

    lowest engine speed.

    Main switch is vary by Palm model.

     Above shows Palm m500 / 505 / 515.

    (i) Switch on Palm

    Tap “ ” of EPVC_Large.Tap “Dr.ZX” icon on Palm.

    (j) Start Dr.ZX (k) Select “ EPVC_Large” . (l) Start operation mode

    Tap “START”.

  • 8/18/2019 140396314-Dr-ZX

    28/192

    8. Operation Mode – Special Function (Pump Adjustment –6/9) 

    Check model. If model is correct, tap

    “correct”, if not tap “ESC” and contact

    to Hitachi.

    (m) Model / Version i nfo rmation

    Tap “ ” of Special Function.

    (n) Select special function

    Tap “ ” of pump adjustment.

    (o) Select pump adjustment

    Tap “ ” of pump adjustment.

    (p) Select Max. Disp. Holding

    Return signals (voltage) from angle

    sensors will display.

    (q) Sensor signal displayed

    NOTE

     After tap “ Max. Disp.

    Holding” , wait more than

    five (5) seconds. Computer 

    wil l operate main pump to

    maximum displacement

    position.

  • 8/18/2019 140396314-Dr-ZX

    29/192

    8. Operation Mode – Special Function (Pump Adjustment –7/9) 

    With the punch mark on the angel sensor shaft, towards the

    opposites side of the harness, and adjust (turn) shaft that

    signal voltage is as following specification.

    ZX450 & ZX500

    Pump-1 angle sensor; 1.60VPump-2 angle sensor; 3.40V

    ZX600 & ZX800

    Pump-1 angle sensor: 1.60V

    Pump-2 angle sensor; 1.60V

     A Sensor 

    Punch

    Mark

    Main pump

    Feedback

    Shaft

    (s) Appl y grease

     Apply a film of grease to the surface of fastener 

    spring, and install I into the cavity on the feedback

    shaft.

    Fastener 

    Spring

    (r) Adjust sensor shaft

  • 8/18/2019 140396314-Dr-ZX

    30/192

    8. Operation Mode – Special Function (Pump Adjustment –8/9) 

    Install sensors to main pump. Set signal voltage as following specifications,

    by adjusting the holes of A (angle) sensor.

    ZX450 & ZX500

    Pump-1 angle sensor; 1.60V +0.02/-0.02

    Pump-2 angle sensor; 3.40V +0.02/-0.02

    ZX600 & 800

    Pump-1 angle sensor; 1.60V +0.02/-0.02

    Pump-2 angle sensor; 1.60V +0.02/-0.02

    (s) Adjust sensors

    Pump-2

    sensor 

    Pump-1

    sensor 

    Harness

    Side

    ZX450 & ZX500 Angle Sensors Location

    Harness

    Side

    Pump-2

    sensor 

    Pump-1

    sensor 

    Harness

    Side

    Engine

    ZX450 & ZX500 Angle Sensors Location

    Harness

    Side

  • 8/18/2019 140396314-Dr-ZX

    31/192

    8. Operation Mode – Special Function (Pump Adjustment –9/9) 

    Tap “ESC” for quit pump adjustment.

    (u) Quit pump adjustment

    Tighten bolts &

    washers.

    (t) Tighten bolts

    Tighten bolts & washers to 9.8Nm (1.0

    kgf-m, 7.2 lbf-ft).

  • 8/18/2019 140396314-Dr-ZX

    32/192

    9. Service Mode – How to Start Dr.ZX with Service Mode (1/4)

    Turn key switch

    “OFF”.

    Switch on the

    engine-learning

    switch.

    Connect Dr.ZX to

    equipment.

    Turn key switch

    “ON”.

    Switch on Palm. Start Dr.ZX. Select

    “EPVC_Large”.

    Start service

    mode.

    Wait more than

    ten(10) seconds.

    Confirm current

    Dr.ZX mode.

    Confirm model.

    Check Engine Learning Data

    Monitor Panel LCD (Liquid Crystal Display) Control

    Change Parameter.

    Service mode

    menu.

    Select Special

    function.

     Activate or Deactivate Changed Parameters

  • 8/18/2019 140396314-Dr-ZX

    33/192

    9. Service Mode – How to Start Dr.ZX with Service Mode (2/4) 

    (b) Switch on Engine-learning switch

    ON

    Fuse box

    NOTE

    Wait more than ten (10)

    seconds, after keyswitch is turned off.

    Stamp

    (a) Turn key swit ch “ OFF”

      (c) Connect Dr.ZX to equipment.

  • 8/18/2019 140396314-Dr-ZX

    34/192

    9. Service Mode – How to Start Dr.ZX with Service Mode (3/4) 

    (d) Turn key switch “ ON”

    Main switch is vary by Palm model.

     Above shows Palm m500 / 505 / 515.

    (f) Start Dr.ZX(e) Switch “ ON” Palm

    Tap “Dr.ZX” icon on Palm.NOTE

    Shall not start engine.

    (g) Select “ EPVC_Large”

    Tap “ ” of EPVC_Large. Check model. If model is correct, tap

    “correct”, if not tap “ESC” and contact

    to Hitachi.

    Tap “START”.

    (i) Model / Version information(h) Start servi ce mode

  • 8/18/2019 140396314-Dr-ZX

    35/192

    9. Service Mode – How to Start Dr.ZX with Service Mode (4/4) 

    Tap “Rechecked”.

    (j) Service mode conf irmation (k) Select “ Special Functi on” (l) Service mode menu

    Tap “ ” of “Special Function”.

  • 8/18/2019 140396314-Dr-ZX

    36/192

    10. Service Mode – Learning Data Display (1/2) 

    Data shows EC motor posi tion when engine stop or engine running on maximum speed.

    Service mode

    menu.

    Select “Learning

    Data Display”.

    Select “Engine

    Stop Position”.

    Position will

    display.

    Select “Engine

    Stop Position”.

    Position will

    display/.

  • 8/18/2019 140396314-Dr-ZX

    37/192

    10. Service Mode – Learning Data Display (2/2) 

    (a) Select “ Learning Data Display” .

    Tap “ ” of “Learning Data Display” in

    service mode menu.

    (b) Select i tem

    Tap “ ” of item you want to view.

    (c) Engine max. speed position

    EC Motor position will display. Tap

    “ESC” for quit.

    EC Motor position will display. Tap

    “ESC” for quit.

    (c) Engine stop pos ition

  • 8/18/2019 140396314-Dr-ZX

    38/192

    11. Service Mode – Monitor Panel LCD Control (1/2) 

    This funct ion i s able or di sable to display actual engine speed and/or hydraulic oil temperature on monitor panel LCD( Liquid

    Crystal Display).

    Display Select

    Switch

    This switch will changeover 

    LCD

    (Liquid Crystal Display)

    Monitor Panel 

    Service mode

    menu.

    Select “Monitor

    Display”.

    Select “Engine

     Actual Speed”.

    Select “display”

    or “not to

    display”.

    Select “Execute”.

    Select “Hydraulic

    Oil Temp.”.

    Select “display”

    or “not to

    display”.

    Select “Execute”.

     

  • 8/18/2019 140396314-Dr-ZX

    39/192

    11. Service Mode – Monitor Panel LCD Control (2/2) 

    (a) Select “ Monitor Display” .

    Tap “ ” of “Monitor Display” in

    service mode menu.

    (b) Select i tem

    Tap “ ” of item you want to view on

    monitor panel.

    Tap “Disp” for allow to display

    information, and tap “NoDisp” for not

    allow to display information.

    (c) Select control

    (c) Execute

    If execution is completed, above

    message will display. Tap “ESC” for 

    quit.

    (c) Quit

    Tap “Execute” for activate control.

  • 8/18/2019 140396314-Dr-ZX

    40/192

    12. Serv ice Mode – Parameter Change (1/4) 

    Please click here for view items can be changed parameters.

    Service mode

    menu.

    Select

    “Parameter

    Change”.

    Select item. Enter parameter.

    Confirmation

    screen.

    Tap “Execute”. End message. Tap “ESC”.

    Select “Execute”.

     

    NOTE

    You have to carry out “ Act /Deact of Parameters”

    function after changing parameters. Otherwise

    changed parameter(s) shall not transfer to

    equipment main computer.

  • 8/18/2019 140396314-Dr-ZX

    41/192

    12. Serv ice Mode – Parameter Change (2/4) 

    (a) Select “ Parameter Change”

    Tap “ ” of “Parameter Change” in

    service mode menu.

    Tap “ ” of item you want to view.

    (c) Enter figures

    Tap entering column, and enter 

    figures to be adjusted.

    TIP

    You can use keyboard to enter 

    figures. Tap “123” on GRAFFITI

    are.

    Tap “ ” or “ ” to

    changeover items.

    (c) Tap “ Execution”

    (b) Select i tem

  • 8/18/2019 140396314-Dr-ZX

    42/192

    12. Serv ice Mode – Parameter Change (3/4) 

    (c) Confirmation screen

    Confirmation screen will display. If 

    figures are correct, tap “Execute”.

    Tap “ESC” to quit.

    (c) Quit

  • 8/18/2019 140396314-Dr-ZX

    43/192

    12. Serv ice Mode – Parameter Change (4/4) 

    Items can be changed parameters (vary by model)

     

  • 8/18/2019 140396314-Dr-ZX

    44/192

    13. Service Mode – Act /Deact of Parameters (1/2) 

    Service modemenu.

    Tap “Act”. Changedparameter(s) will

    reflect to

    computer.

    Will deact

    changed

    parameter(s) in

    computer

    Tap “Deact”.

    Select“Act/Deact of

    Parameters“.

  • 8/18/2019 140396314-Dr-ZX

    45/192

    13. Service Mode – Act /Deact of Parameters (2/2) 

    (a) Select “ Parameter Change”

    Tap “ ” of “Parameter Change” in

    service mode menu.

    (b) Select “ Act” or “ Deact”.

    Select activation or 

    deactivation.

    Tap “Execute”, and tap “ESC” to quit.

    (c-1) Activation

    Tap “Execute”, and tap “ESC” to quit.

    (c-1) Deactivation

    1 S S S (1/2)

  • 8/18/2019 140396314-Dr-ZX

    46/192

    14. Stand Alone Mode - How to Start Dr.ZX with Stand Alone Mode (1/2) 

    Play recorded

    monitoring data.

    View manuals.

    Main screen. Change passwordStart“EPVC_Large”.

    Start Dr.ZX.Switch on Palm. 

    14 St d Al M d H t St t D ZX ith St d Al M d (2/2)

  • 8/18/2019 140396314-Dr-ZX

    47/192

    14. Stand Alone Mode - How to Start Dr.ZX with Stand Alone Mode (2/2)

    Tap “Dr.ZX” icon on Palm.

    (b) Start Dr.ZX

    Main switch is vary by Palm model.

     Above shows Palm m500 / 505 / 515.

    (a) Switch “ ON” Palm

    NOTE

    No need to hook up

    with equipment.

    (c) Select “ EPVC_Large”

    Tap “ ” of EPVC_Large.

    (d) Main screen

    15 St d Al M d Ch P d (1/3)

  • 8/18/2019 140396314-Dr-ZX

    48/192

    15. Stand Alone Mode – Change Password (1/3) 

    Main screen. Tap “Password”. Enter currentpassword.

    New password

    will apply.

    Re-enter newpassword.

    NOTE

    New password will apply to

    all Dr.ZX function.

    Enter newpassword.

    15 Stand Alone Mode Change Password (2/3)

  • 8/18/2019 140396314-Dr-ZX

    49/192

    15. Stand Alone Mode – Change Password (2/3) 

    Tap “Password”.

    (a) Main screen

    Enter current password. Default

    password is zx2000.

    (b) Enter current password

    TIP

    You can use keyboard to enter 

    password. Tap “abc” on GRAFFITI

    are.

    (c) Tap “ Execute” (d) Enter new password (e) Tap “ Execute”

    15 Stand Alone Mode Change Password (3/3)

  • 8/18/2019 140396314-Dr-ZX

    50/192

    15. Stand Alone Mode – Change Password (3/3) 

    (f) Re-enter new password (g) Tap “ Execute” (h) Tap “ ESC”

    Password has been changed.

    16 Stand Alone Mode View Manuals (1/2)

  • 8/18/2019 140396314-Dr-ZX

    51/192

    16. Stand Alone Mode – View Manuals (1/2) 

    View service

    mode manual.

    View operationmode manual.

    View engine

    learning mode

    manual.

    Select Manual.Tap “Op Manual”.Main screen.

    16 Stand Alone Mode – View Manuals (2/2)

  • 8/18/2019 140396314-Dr-ZX

    52/192

    16. Stand Alone Mode View Manuals (2/2) 

    Tap “ ” of mode that you want to

    view manual.

    (a) Main screen

    Tap ”Op. Manual”.

    (b) Select Manual

    (c) Operation mode manual

    Tap “ESC” to quit.

    (d) Service mode manual (e) Engine learning mode manual

     

    17 Stand Alone Mode – Play Recorded Data (1/2)

  • 8/18/2019 140396314-Dr-ZX

    53/192

    17. Stand Alone Mode Play Recorded Data (1/2) 

    Tap “RecordDisp”.

    Play recordeddata.

    Select data bank.Main screen.

    NOTE

    To play recoded data, you have to record monitoring

    data before.

    17. Stand Alone Mode – Play Recorded Data (2/2)

  • 8/18/2019 140396314-Dr-ZX

    54/192

    17. Stand Alone Mode Play Recorded Data (2/2) 

    Tap number of data bank that you

    want to play, and tap “Play Back”.

    (a) Main screen

    Tap ”Record Disp”.

    (b) Select data bank

    Recorded monitoring data will display.

    Tap “ESC” to quit.

    (c) Recoded data

     

  • 8/18/2019 140396314-Dr-ZX

    55/192

    EPVC_MID

    Operation Manual

    Hitachi Construct ion Machinery Co. Ltd. 

    NOTEThis manual is based on Hitachi ZX series. Screen / Function /

    Procedure are vary by model.

     

  • 8/18/2019 140396314-Dr-ZX

    56/192

    1. Necessary Tools & Cable Connection

    2. MODEOPERATION MODE

    3. Operation Mode – How to Start Dr.ZX with Operation Mode

    4. Operation Mode – Self-Diagnosti c

    5. Operation Mode – Monitor ing

    6. Operation Mode – Special Funct ion (WU Deactivation)

    7. Operation Mode – Special Func tion (ECO Deactivation)

     

    SERVICE MODE

    8. Service Mode – How to Start Dr.ZX with Service Mode

    9. Service Mode – Learning Data Display

    10. Service Mode – Monitor Panel LCD Contro l

    11. Servi ce Mode – Parameter Change

     

    STAND ALONE MODE

    12. Stand Alone Mode - How to Start Dr.ZX with Stand Alone Mode

    13. Stand Alone Mode – Change Password

    14. Stand Alone Mode – View Manuals

    15. Stand Alone Mode – Play Recorded Data

     

    1. Necessary Tools & Cable Connection

  • 8/18/2019 140396314-Dr-ZX

    57/192

    y

    Cable connection

    (a) Palm OS PDA (b) Serial cable (c) Dr.ZX communication cable

    Dr.ZX must be ins talled. Hitachi

    recommends following models.

    SONY

    Clie PEG-TJ25

    PalmOne Inc.

    m125 / 130 / 500 / 505 / 515Tungsten T2 / T3 / C

    For SONY Clie PEG-TJ25

    Purchase from CPD. P/no. is

    4629330 (Hitachi unique

    parts).

    For PalmOne PDAs

    Purchase from local market.Product name is HotSync serial

    This is Hitachi unique part. Make an

    order to your parts ordering channel.

    Hitachi part no. is 4476512.

    Dr.ZX cable Serial cable Palm OS PDA Palm

    Serial cable

    Dr.ZX cable

    Equipment

    Connect to

    Dr.ZX

    connector.

    Necessary tools

    2. MODE

  • 8/18/2019 140396314-Dr-ZX

    58/192

    Start Dr.ZX withOperation Mode 

    Self-DiagnosticMonitoring / Recording Sensor out-put signal

    WU (Warming-up function) Deactivation

    ECO (Economy function) Deactivation

    Start Dr.ZX with

    Service Mode.

    Check Engine Learning Data

    Monitor Engine Speed & Hydraulic Oil Temperature

    Change Parameter(s), such as follows

    Engine RPM

     Auto-Lub. IntervalPump Max. Displacement

    Pump Max. Torque

    Pump Cut-off Pressure

    Change Password

    Replay Recorded Monitoring Data

    Refer Instant Operation Manual

    Dr.ZX

    NOTE

    For non-current models (such

    as EX-2/-3/-5), operation &

    stand-alone mode will apply

    Stand-alone

    Mode (No need

    to hock up with

    equipment)

    3. Operation Mode – How to Start Dr.ZX with Operation Mode (1/5)

  • 8/18/2019 140396314-Dr-ZX

    59/192

    Turn key switch“OFF”.

    Check enginelearning switch is

    OFF.

    Connect Dr.ZX toequipment.

    Turn key switch“ON”.

    Start Dr.ZX. Select

    “EPVC_Mid”.

    Start operation

    mode.

    Special Function

    Monitoring

    View / Recording

    Self - DiagnosticOperation mode

    menu.

    Switch on Palm. 

    3. Operation Mode – How to Start Dr.ZX with Operation (2/5) 

  • 8/18/2019 140396314-Dr-ZX

    60/192

    (b) Check Engine learning swi tch i s OFF

    Stamp

    Hitachi ZAXIS110 & up

    (a) Turn key swit ch “ OFF”

    Hitachi ZAXIS70, 80, 75US,

    75UR, 135US, 225US

    3. Operation Mode – How to Start Dr.ZX with Operation (3/5) 

  • 8/18/2019 140396314-Dr-ZX

    61/192

    Hitachi ZAXIS70, 80, 75US,

    75UR, 135US, 225US

    Hitachi ZAXIS110 & up

    (c) Connect Dr.ZX to equipment.

    3. Operation Mode – How to Start Dr.ZX with Operation Mode (4/5) 

  • 8/18/2019 140396314-Dr-ZX

    62/192

    (d) Turn key switch “ ON”

    Main switch is vary by Palm model.

     Above shows Palm m500 / 505 / 515.

    (f) Start Dr.ZX(e) Switch “ ON” Palm

    Tap “Dr.ZX” icon on Palm.

    (g) Select “ EPVC_Mid”

    Tap “ ” of EPVC_Mid. Check model. If model is correct, tap

    “correct”, if not tap “ESC” and contact

    to your dealer.

    (i) Model / Version information(h) Start operation mode

    Tap “START”.

    3. Operation Mode – How to Start Dr.ZX with Operation Mode (5/5) 

  • 8/18/2019 140396314-Dr-ZX

    63/192

    (j) Operation mode main menu

    4. Operation Mode – Self-Diagnostic (1/3) 

  • 8/18/2019 140396314-Dr-ZX

    64/192

    Select“Self-diagnostic”.

    No errordetected.

    Message willdisplay.

    Start Dr.ZX withOperation mode.

    Error(s) are

    detected.

    Tap “Details” for

    check detail of

    each error code.

    Error code(s) will

    display.

    Tap “ESC”. Carry out

    “Retry”.

    Still error(s) are

    detected

    No error 

    detected.

    Message will

    display.

    Error code(s) will

    display.

    4. Operation Mode – Self-Diagnostic (2/3) 

  • 8/18/2019 140396314-Dr-ZX

    65/192

    (b) No error detected

    If Dr.ZX could not detect any error(s),

    above message will display. Tap

    “ESC”.

    (a) Start self-diagnos tic

    Tap “ ” of Self-Diagnostic.

    If Dr.ZX could not detect any error(s),

    above message will display. Tap

    “ESC”.

    Tap “Retry B” for retrying.

    (e) No error detected(c) Error(s) detected (d) Retry

    Error code(s) that detected will

    display to Palm. Tap “ESC” for retry.

    4. Operation Mode – Self-Diagnostic (3/3) 

    (f) S ( ) ( ) f ( ) f

  • 8/18/2019 140396314-Dr-ZX

    66/192

    (f) Stil l error (s) detected

    If Dr.ZX still detect any error(s) , error 

    code(s) will display. Tap “Details” for 

    check error(s).

    (g) Explanation of each code

    Message will show meanings of each

    code, and corrective action. Tap

    “Next” for view additional information

    or other code.

    (h) Explanation of each code

    Tap “ESC” fir quit self-diagnostic.

    NOTE

    Refer service manuals for 

    troubleshooting.

    5. Operation Mode – Monitoring (1/5) 

  • 8/18/2019 140396314-Dr-ZX

    67/192

    Select Monitor display.

    Enter modelcode & serial no.

    Select item.(Max. four items)

    Start monitoring.

    Write recorded

    data to data

    bank.

    Start recording. If data bank isn’t

    empty, Dr.ZX will

    ask overwrite.

    Enter comment if

    you want.

    Select data bank

    that store

    recorded data.

    Operation modemenu.

    NOTE

    If you did not enter model code & equipment

    serial no., you can’t record monitori ng data to

    Palm.

    5. Operation Mode – Monitoring (2/5) 

    (b) Enter model code & s/no(a) Start Monitoring

  • 8/18/2019 140396314-Dr-ZX

    68/192

    Tap columns and enter model code &

    serial no. If you did not enter model

    code & serial no., you can’t record

    monitoring data.

    (b) Enter model code & s/no.(a) Start Monitoring

    Tap “ ” of Monitor Display

    TIP

    You can use keyboard to enter 

    model code & serial no. by tap

    “abc” or “123” on GRAFFITI area.

    Selected item

    Number of

    selected item(s).Clear selected

    item(s).

    Item

    changeover

    button

     After enter model & serial no., tap

    “OK”. If you don’t need to record

    monitoring data, no need to enter 

    model code & serial no. Just tap “OK”.

    Tap “ ” of item you want monitor. You

    can monitor four items in once.

    (d) Select monitoring item(s)(c) Tap “ OK”

    5. Operation Mode – Monitoring (3/5) 

    (e) Start display data (f) Start display monitoring data

  • 8/18/2019 140396314-Dr-ZX

    69/192

     After selecting item(s), tap “Start” for 

    display monitoring data.

    (e) Start display data

    Item(s) will display. Screen will vary

    by selected items. Tap “Hold” for 

    pause data. If you want quit, tap

    “ESC”.

    (f) Start display monitoring data

    (h) Recording(g) Start Recording

    Tap “Record” for record monitoring

    data. Dr.ZX will record data for three

    (3) seconds.

    During recording, above screen will

    display.

    NOTE

    If you did not enter 

    model code & serial no.,

    “Record” but ton shal l

    not appear.

    5. Operation Mode – Monitoring (4/5) 

    (k) Data bank is empty(i) Select data bank (j) Data bank is not empty

  • 8/18/2019 140396314-Dr-ZX

    70/192

    (k) Data bank is empty

    If selected data bank is empty, above

    screen will display. Tap “Write” for 

    store recorded monitoring data.

    (l) Confirmation

     After data stored, confirmation screen

    will display. Tap “ESC” for quit, or if 

    you want enter comment, tap

    “Comment”.

    (l) Enter comment TIP

    You can use keyboard to enter 

    comment. Tap “abc” on GRAFFITI

    are.

    (i) Select data bank

    Tap data bank (figure) that you want

    to store recorded data.

    If selected data bank already has

    data, above screen will appear. Tap

    “OverWrite” for store recorded data,

    tap “ESC” for back to previous menu.

    (j) Data bank is not empty

    Tap comment column, and enter 

    comment. After entering, tap “OK”.NOTE

    Click here for how to replay

    recorded data.

    5. Operation Mode – Monitoring (5/5) 

    Items can be moni tored (vary by model)

  • 8/18/2019 140396314-Dr-ZX

    71/192

    Items can be moni tored (vary by model)

    6. Operation Mode – Special Function (WU Deactivation –1/2) 

  • 8/18/2019 140396314-Dr-ZX

    72/192

    Select Special

    Function.

    Select WU

    Deactivation

    WU has

    deactivated.

    ExecuteSpecial function

    menu

    WU Function.

    WU stands for Warming-Up. This function is, when start engine while hydraulic oil

    temperature is less than zero (0) Celsius, computer will increase low idle rpm for warm

    hydraulic oil qu ickly.

    6. Operation Mode – Special Function (WU Deactivation –2/2) 

    (a) Select special func tion (b) Select WU deactivation (c) Select WU deactivation

  • 8/18/2019 140396314-Dr-ZX

    73/192

    Tap “Execute for Deactivation. If you

    want back to previous menu, tap

    “ESC”.

    Tap “ ” of WU Deactivation..Tap “ ” of Special Function.

     After deactivation, above message

    will display. Tap ”ESC” for quit.

    (d) Confirmation

    NOTE

    WU (Warming-up function) will

    re-activate when key switch is

    turned “ OFF”.

    7. Operation Mode – Special Function (ECO Deactivation –1/2) 

  • 8/18/2019 140396314-Dr-ZX

    74/192

    Select Special

    Function.

    Select ECO

    Deactivation ECO has

    deactivated.

    ExecuteSpecial function

    menu

    ECO Funct ion

    ECO stands for ECOnomy. This function is, when all levers are in neutral position,

    computer wi ll reduce engine rpm to 1600min-1 gradually. If any lever(s) are operated, engine

    rpm will back. 

    7. Operation Mode – Special Function (ECO Deactivation –2/2) 

    (a) Select special func tion (b) Select ECO deactivation (c) Select WU deactivation

  • 8/18/2019 140396314-Dr-ZX

    75/192

    Tap “ ” of ECO Deactivation..Tap “ ” of Special Function. Tap “Execute for Deactivation. If you

    want back to previous menu, tap

    “ESC”.

     After deactivation, above message

    will display. Tap ”ESC” for quit.

    (d) Confirmation

    NOTE

    ECO (Economy function) will

    re-activate when key switch is

    turned “ OFF”.

    8. Service Mode – How to Start Dr.ZX with Service Mode (1/5)

  • 8/18/2019 140396314-Dr-ZX

    76/192

    Turn key switch

    “OFF”.

    Switch on the

    engine-learning

    switch.

    Connect Dr.ZX to

    equipment.

    Turn key switch

    “ON”.

    Switch on Palm. Start Dr.ZX. Select

    “EPVC_Mid”.

    Start service

    mode.

    Wait more than

    ten(10) seconds.

    Confirm current

    Dr.ZX mode.

    Confirm model.

    Check Engine Learning Data

    Monitor Panel LCD (Liquid Crystal Display) Control

    Change Parameter.

    Service mode

    menu.

    Select Special

    function.

     Activate or Deactivate Changed Parameters

    8. Service Mode – How to Start Dr.ZX with Service Mode (2/5) 

    (a) Turn key swit ch “ OFF” (b) Switch on the Engine-learning switch

  • 8/18/2019 140396314-Dr-ZX

    77/192

    ZX110 & up, 120C & up

    Stamp

    NOTE

    Wait more than ten (10)

    seconds, after key

    switch is turned off.

    ZX70/80/75US/75UR & 80C

    8. Service Mode – How to Start Dr.ZX with Service Mode (3/5) 

    (c) Connect Dr.ZX to equipment.

  • 8/18/2019 140396314-Dr-ZX

    78/192

    Hitachi ZAXIS70, 80, 75US,

    75UR, 135US, 225US

    Hitachi ZAXIS110 & up

    8. Service Mode – How to Start Dr.ZX with Service Mode (4/5) 

    (d) Turn key switch “ ON” (f) Start Dr.ZX(e) Switch “ ON” Palm

  • 8/18/2019 140396314-Dr-ZX

    79/192

    Main switch is vary by Palm model.

     Above shows Palm m500 / 505 / 515.

    Tap “Dr.ZX” icon on Palm.NOTEShall not start engine.

    (g) Select “ EPVC_Large”

    Tap “ ” of EPVC_Mid. Check model. If model is correct, tap

    “correct”, if not tap “ESC” and contact

    to Hitachi.

    (i) Model / Version information(h) Start servi ce mode

    Tap “START”.

    8. Service Mode – How to Start Dr.ZX with Service Mode (5/5) 

    (j) Service mode conf irmation (k) Select “ Special Functi on” (l) Service mode menu

  • 8/18/2019 140396314-Dr-ZX

    80/192

    Tap “Rechecked”. Tap “ ” of “Special Function”.

    9. Service Mode – Learning Data Display (1/2) 

    Data shows EC motor posi tion when engine stop or engine running on maximum speed.

  • 8/18/2019 140396314-Dr-ZX

    81/192

    Service mode

    menu.

    Select “Learning

    Data Display”.

    Select “Engine

    Stop Position”.

    Position will

    display.

    Select “Engine

    Stop Position”.

    Position will

    display/.

    9. Service Mode – Learning Data Display (2/2) 

    (a) Select “ Learning Data Display” . (b) Select i tem (c) Engine stop pos ition

  • 8/18/2019 140396314-Dr-ZX

    82/192

    Tap “ ” of “Learning Data Display” in

    service mode menu.

    Tap “ ” of item you want to view.

    (c) Engine max. speed position

    EC Motor position will display. Tap

    “ESC” for quit.

    NOTE

    “ Boom Angle Sensor Correction

    Value” & “ Arm Angle Sensor 

    Correction Value” are used for 

    equipment which has lifting load

    monitor (option item).

    EC Motor position will display. Tap

    “ESC” for quit.

    10. Service Mode – Monitor Panel LCD Control (1/2) 

    This funct ion i s able or di sable to display actual engine speed and/or hydraulic oil temperature on monitor panel LCD( Liquid

    Crystal Display).

  • 8/18/2019 140396314-Dr-ZX

    83/192

    Display Select

    Switch

    This switch will changeover 

    LCD

    (Liquid Crystal Display)

    Monitor Panel 

    Service mode

    menu.

    Select “Monitor

    Display”.

    Select “Engine

     Actual Speed”.

    Select “display”

    or “not to

    display”.

    Select “Execute”.

    Select “HydraulicOil Temp.”.

    Select “display”or “not to

    display”.

    Select “Execute”.

     

    10. Service Mode – Monitor Panel LCD Control (2/2) 

    (a) Select “ Monitor Display” . (b) Select i tem

    NOTE

  • 8/18/2019 140396314-Dr-ZX

    84/192

    Tap “ ” of “Monitor Display” in

    service mode menu.

    Tap “ ” of item you want to view on

    monitor panel.

    “ Over Load Alarm” only apply to

    equipment which has lifting load

    monitor (option).

    “ Hyd. Oil Filter LED” only applies to

    equipment which has high

    specification full-flow fil ter (option)

    (c) Select cont rol (c) Execute

    Tap “Disp” for allow to display

    information, and tap “NoDisp” for not

    allow to display information.

    If execution is completed, above

    message will display. Tap “ESC” for 

    quit.

    (c) Quit

    Tap “Execute” for activate control.

    11. Service Mode – Parameter Change (1/4) 

    Please click here for view items can be changed parameters.

  • 8/18/2019 140396314-Dr-ZX

    85/192

    Service mode

    menu.

    Select

    “Parameter

    Change”.

    Select item. Enter parameter.

    Confirmation

    screen.

    Tap “Execute”. End message. Tap “ESC”.

    Select “Execute”.

     

  • 8/18/2019 140396314-Dr-ZX

    86/192

    11. Service Mode – Parameter Change (3/4) 

    (e) Confi rmation screen (f) Quit

  • 8/18/2019 140396314-Dr-ZX

    87/192

    Confirmation screen will display. If 

    figures are correct, tap “Execute”.

    Tap “ESC” for quit. NOTE

    Changed parameter will reflect to

    computer immediately after qu it.

     

    11. Service Mode – Parameter Change (4/4) 

    Items can be changed parameters (vary by model)

  • 8/18/2019 140396314-Dr-ZX

    88/192

     

    12. Stand Alone Mode - How to Start Dr.ZX with Stand Alone Mode (1/2) 

    Main screen. Change passwordStart

    “EPVC Large”

    Start Dr.ZX.Switch on Palm.

  • 8/18/2019 140396314-Dr-ZX

    89/192

    Play recorded

    monitoring data.

    View manuals.

    “EPVC_Large”. 

    12. Stand Alone Mode - How to Start Dr.ZX with Stand Alone Mode (2/2)

    (b) Start Dr.ZX(a) Switch “ ON” Palm

  • 8/18/2019 140396314-Dr-ZX

    90/192

    Tap “Dr.ZX” icon on Palm.Main switch is vary by Palm model.

     Above shows Palm m500 / 505 / 515. No need to hook up

    with equipment.

    NOTE

    (c) Select “ EPVC_Mid”

    ” of EPVC_Large.Tap “

    (d) Main screen

    13. Stand Alone Mode – Change Password (1/3) 

    Main screen. Tap “Password”. Enter current

    password

    Re-enter new

    password

    Enter new

    password

  • 8/18/2019 140396314-Dr-ZX

    91/192

    password.

    New password

    will apply.

    password.

    New password will apply to

    all Dr.ZX function.

    NOTE

    password.

    13. Stand Alone Mode – Change Password (2/3) 

    (a) Main screen (b) Enter current password

  • 8/18/2019 140396314-Dr-ZX

    92/192

    Tap “Password”. Enter current password. Default

    password is zx2000.

    TIP

    You can use keyboard to enter 

    password. Tap “abc” on GRAFFITI

    are.

    (c) Tap “ Execute” (d) Enter new password (e) Tap “ Execute”

    13. Stand Alone Mode – Change Password (3/3) 

    (f) Re-enter new passwrod (g) Tap “ Execute” (h) Tap “ ESC”

  • 8/18/2019 140396314-Dr-ZX

    93/192

    Password has been changed.

    14. Stand Alone Mode – View Manuals (1/2) 

    View operation

    mode manual.

    Select Manual.Tap “Op Manual”.Main screen.

  • 8/18/2019 140396314-Dr-ZX

    94/192

    View servicemode manual.

    View engine

    learning mode

    manual.

    14. Stand Alone Mode – View Manuals (2/2) 

    (a) Main screen (b) Select Manual

  • 8/18/2019 140396314-Dr-ZX

    95/192

    Tap “ ” of mode that you want to

    view manual.

    Tap ”Op. Manual”.

    (c) Operation mode manual

    Tap “ESC” to quit.

    (d) Service mode manual (e) Engine learning mode manual

     

    15. Stand Alone Mode – Play Recorded Data (1/2) 

    Tap “Record

    Disp”.

    Play recorded

    data.

    Select data bank.Main screen.

  • 8/18/2019 140396314-Dr-ZX

    96/192

    To play recoded data, you have to record monitoringdata before.

    NOTE

    15. Stand Alone Mode – Play Recorded Data (2/2) 

    (a) Main screen (b) Select data bank (c) Recoded data

  • 8/18/2019 140396314-Dr-ZX

    97/192

    Tap number of data bank that you

    want to play, and tap “Play Back”.

    Tap ”Record Disp”. Recorded monitoring data will display.

    Tap “ESC” to quit.

     

    EPVC Mini

  • 8/18/2019 140396314-Dr-ZX

    98/192

    EPVC_MiniOperation Manual

    Hitachi Construct ion Machinery Co. Ltd. 

    This manual is based on Hitachi ZX series. Screen / Function /

    Procedure are vary by model.

    NOTE

     

    1. Necessary Tools & Cable Connection

    2. Function

    3. How to Start EPVC_Mini4 Displaying & Deleting Fault Code History

  • 8/18/2019 140396314-Dr-ZX

    99/192

    4. Displaying & Deleting Fault Code History

    5. Troubleshooting

    6. Fault Codes List

    7. Zone check

    8. Monitoring

    9. Current Correction

    1. Necessary Tools & Cable Connection

    (a) Palm OS PDA (b) Serial cable (c) Dr.ZX communication cable

    Necessary tools

  • 8/18/2019 140396314-Dr-ZX

    100/192

    Cable connection

    Dr.ZX must be ins talled. Hitachi

    recommends following models.

    SONY

    Clie PEG-TJ25

    PalmOne Inc.

    m125 / 130 / 500 / 505 / 515

    Tungsten T2 / T3 / C

    For SONY Clie PEG-TJ25

    Purchase from CPD. P/no. is

    4629330 (Hitachi unique

    parts).

    For PalmOne PDAs

    Purchase from local market.

    Product name is HotSync serial

    This is Hitachi unique part. Make an

    order to your parts ordering channel.

    Hitachi part no. is 4476512.

    Dr.ZX cable Serial cable Palm OS PDA Palm

    Serial cable

    Dr.ZX cable

    Equipment

    Connect to

    Dr.ZX

    connector.

    2. Funct ion

    Fault Code Disp & Del

    This function will show or delete fault code & operation history that memorized in

    controller Controller can keep 59 records If more than 59 fault code and/or operation

    EPVC Mini

  • 8/18/2019 140396314-Dr-ZX

    101/192

    controller. Controller can keep 59 records. If more than 59 fault code and/or operation

    occurred, controller would overwrite latest information to oldest record. Computer will

    Troubleshooting

    This function will display fault code that controller is sensing. If any trouble is

    occurring, PDA will shoe fault code. If PDA could not detect any fault, PDA will display

    “00” on each items.

    Use this function when you feel boom stop position it too close or far.

    (b) Boom stop position (adjusting range is +/- 20 degree)

    Use this function when you feel deceleration speed is too slow.

    (a) Boom & swing deceleration currency (adjusting range is +/- 100 mA)

    This function allows to correct following items

    Current Correction

    This function allows monitoring item. You can check four items in once.

    Monitor Display

    ZONE Check

    This function will display current boom & swing position.

    3. How to Start EPVC_Mini -1/3

    Turn key switch

    “OFF”.

    Connect Dr.ZX to

    equipment.

    Turn key switch

    “ON”.

    Switch on PDA Start Dr.ZX.

  • 8/18/2019 140396314-Dr-ZX

    102/192

    Kind menu will

    display. Select

    “EPVC_Mini”.

    Main menu will

    display. Select

    “Mu” type.

    Main menu will

    display.

    Software version

    will display.

    Select “Start”.

    Equipment

    information will

    display. Select

    “OK”.

    3. How to Start EPVC_Mini -2/3 

    (c) Turn key switch “ ON”(a) Turn key swit ch “ OFF” (b) Connect cable to equipment

    Remove small oval-shape plastic cap

    locate on right side of cab. Pull

    f

  • 8/18/2019 140396314-Dr-ZX

    103/192

    Tap “ ” of “EPVC_Mini”.Tap “Dr.ZX” icon. Above shows PalmOne m500. Switch

    location is vary by model.

    (d) Switch on PDA (e) Start Dr.ZX (f) Kind menu

    connector from hole, and connect

    PDA.

    3. How to Start EPVC_Mini -3/3 

    (g) Main menu (i) Equipment information(h) Software version

  • 8/18/2019 140396314-Dr-ZX

    104/192

    Equipment information will display.Tap “OK” to continue. Tap “Model

    Menu” to back to software version

    display screen.

    Software version will display. Tap“Start” to continue. Tap “Exit” to back

    to main menu.

    Tap “ ” of “Mu Type”. Tap “KindMenu” to back to kind menu.

    Item menu will display.

    (j) Item menu

    4. Displaying & Deleting Fault Code History -1/3 

    No fault code are

    detected.

    Message will

    display.

    .Select “Fault

    Code Disp & Del”

    in item menu.

  • 8/18/2019 140396314-Dr-ZX

    105/192

    Fault (s) are

    detected.

    Will Back to item

    menu.

    Tap “Exit”

    Tap “Info”. Content of fault

    will display.

    Fault code(s) will

    display.

     All Fault history

    will delete.

    Tap “Delete”

    4. Displaying & Deleting Fault Code History -2/3 

    (a) Item menu (b) No faults detected

  • 8/18/2019 140396314-Dr-ZX

    106/192

    Tap “ ” of “Fault Code Disp & Del”. If there aren’t any fault recorded incontroller, above message will

    display. Tap “Exit” to

    Meaning of each code will display.

    Tap ““ ” or “ ” to check other code.

    Tap “Exit” to back to fault code list.

    Tap “Info.”Fault codes will display (max. 59

    faults). Tap ““ ” or “ ” to

    changeover screen.

    (c) Faults detected (e) Check meaning of code (f) Meanings

    4. Displaying & Deleting Fault Code History -3/3 

    (c) End message(g) Delete codes (h) Confirmation screen

  • 8/18/2019 140396314-Dr-ZX

    107/192

    Tap “Delete”. This will clear all faultcode history recording in controller.

    Tap “Yes” to delete code. Tap “NO” toback to code list.

    When clearing is finished, endmessage will display. Tap “OK” to

    back to item menu.

    5. Troubleshooting  

    (c) Check meaning of fault code(a) Item menu (b)List of fault codes

  • 8/18/2019 140396314-Dr-ZX

    108/192

    Tap “ ” of “Troubleshooting” in itemmenu.

    If any faults are occurring, fault codewill display. If no faults are occurring,

    code will display as “00”. Tap “HOLD”

    to check content of fault.

    Tap “Info.” to show meaning of eachcode. Tap “Exit” to back to item menu.

    Meaning will display. Tap “Exit” to

    back to list of fault code.

    (d) Meaning of fault code

    6. Fault Codes List  

    List of Codes

    Code Description Code

    10 Abnormal CPU condition code register 75 Excessive swing sensor output signal (5V side)11 Abnormal CPU General Register 80 Abnormal boom angle sensor (0V side)

    12 Abnormal CPU mode diagnosis 81 Abnormal swing angle sensor (0V side)

  • 8/18/2019 140396314-Dr-ZX

    109/192

    12 Abnormal CPU mode diagnosis 81 Abnormal swing angle sensor (0V side)

    18 Abnormal Interruption test 84 Abnormal boom angle sensor (5V side)

    19 Abnormal 16 bit timer (CH1) 85 Abnormal swing angle sensor (5V side)

    1A Abnormal 16 bit timer (CH2) A0 Abnormal 12V power voltage (Less than 10V)

    1B Abnormal 16 bit timer (CH3) A1 Abnormal 12V power voltage (More than 16V)

    1C Abnormal 8 bit timer   F0 Initial setting has been done properly

    1D Abnormal internal watch dog F1 Deactivate auto boom stop

    20 Abnormal RAM read / write F2 Activate auto boom stop

    40 Abnormal boom-up solenoid F3 Boom entered to critical zone with deactivating auto boom stop

    41 Abnormal swing-right solenoid F4 Boom entered to critical zone with activating auto boom stop

    43 Abnormal pilot shut-off relay F5 Boom moved out from critical zone

    50 Abnormal boon sensor (0V side) F6 Boom moved doper in the critical zone.

    51 Abnormal swing sensor (0V side)

    54 Abnormal boon sensor (5V side)

    55 Abnormal swing sensor (5V side)

    60 Faulty boom sensor initial set value (Lower limit)

    62 Faulty swing sensor initial set value (Lower limit)

    64 Faulty boom sensor initial set value (Upper limit)66 Faulty swing sensor initial set value (Upper limit)

    70 Excessive boom sensor output signal (0V side)

    71 Excessive swing sensor output signal (0V side)

    74 Excessive boom sensor output signal (5V side)

    7. Zone check -1/3 

    (a) Item menu (a) Item menu

  • 8/18/2019 140396314-Dr-ZX

    110/192

    Tap “ ” of “Zone Check”. Current boom & swing position willdisplay. Tap “Exit” to back to item

    menu.

    7. Zone check -2/3 

    Boom Deceleration / Stop Zone

    Max. swing

    Max boom up Boom lower  

     

  • 8/18/2019 140396314-Dr-ZX

    111/192

    B  J L 2 

    B  J L 4 

    B  J L  6 

    B6B5

    B4

    B3

    B2

    B1

    B7

    B  J L 1 

    (Right side)

    Center swing

    Position

    Max. swing

    (Left side)

    Right swing

    Left swing

    B  J L  3 

    Code Description Code Description

    BJL Zone judging line by boom angle. B5 Boom up deceleration zone

    B1 Boom up critical zone B6 Boom up normal zone

    B2 Boom up stop zone B7 Boom up deceleration zone (Height limit)

    B3 Boom up deceleration zone

    B4 Boom up deceleration zone (front of operator)

    7. Zone check -3/3 

    Swing Deceleration / Stop Zone

    Max boom up Boom lower  

     

    S6Max. swing 

  • 8/18/2019 140396314-Dr-ZX

    112/192

    SJL4

    SJL2

    S4

    S3

    S6

    S2

    S1

    SJL3

    SJL5

    Max. swing

    (Left side)

    Center swing

    Position

    (Right side)

    Right swing

    Left swing

    Code Description Code Description

    BJL Zone judging line by boom angle. S3 Right swing deceleration zone

    SJL Zone judging line by swing angle. S4 Right swing deceleration zone

    S1 Right swing critical zone S5 Right swing normal zone

    S2 Right swing stop zone S6 Right swing deceleration zone (End of right swing)

    8. Monitoring  Selected item Item

    changeover

    button

    (a) Item menu (b) Item menu

  • 8/18/2019 140396314-Dr-ZX

    113/192

    Number of

    elected item(s).sClear selected

    item(s).

    Tap “Start” to start monitoring.

    Tap “ ” of “Monitoring Display”. Tap “ ” of item you want monitor. Youcan monitor four items in once.

    (c) Start monitor ing

    Item(s) that you selected will display

    (information will vary by item). Tap

    “Hold” to pause data, and tap “Exit” to

    quit monitoring.

    (d) Monitoring

    9. Current Correction –1/2

    (a) Item menu (b) Item menu (c) Changing value

  • 8/18/2019 140396314-Dr-ZX

    114/192

    Tap “ ” of “Current Correction”. Tap “ ” of item you want changecurrent.

    Confirm figures you changed, and tap

    “OK”. If you want to correct, tap “Exit”.

    (d) Confirmation screen

    To send figures to computer in

    equipment, you have to enter 

    password. Tap password area, and

    enter “FF”.

    (e) Enter password

    Tap figures you want to change, andtap “OK”. To find figures tap “ ” or “ ”.

    If you selected “boom stop position”

    unit will be degree.

    TIP

    You can use keyboard to enter 

    password. Tap “abc” on GRAFFITI

    area.

    9. Current Correction –2/2 

    (f) Enter password (g) End message

  • 8/18/2019 140396314-Dr-ZX

    115/192

     After entering password, tap “OK”. End message will display. Tap “Exit”to quit.

     

    HMS LargeMid

  • 8/18/2019 140396314-Dr-ZX

    116/192

    _ gOperation Manual

    Hitachi Construct ion Machinery Co. Ltd. 

    NOTE

    This manual is based on Hitachi ZX series. Screen / Function /

    Procedure are vary by model.

    Downloaded data wil l belong to customer. Shall not disc lose data to

    thi rd parties, or to even internal personnel, if they aren’t authorized.

     

     

    1. Necessary Tools & Cable Connection

    2. Function

    ICX INITIALIZING3. ICX Initializing – How to start Dr.ZX

    4. ICX Initializing – General Flow

    5 ICX I iti li i S t Ti Diff f GMT

  • 8/18/2019 140396314-Dr-ZX

    117/192

    5. ICX Initializing – Set Time Difference from GMT

    6. ICX Initializing – Set Local Time

    7. ICX Initializing – Synchron ize Service-meter 

    8. ICX Initializing – Model Code & Serial No. Setting

     

    DOWNLOADING

    9. Data Downloading – How to Start Dr.ZX

    10. Data Downloading – Download

    11. Data Downloading – Check Downloaded Data

     

    ICX DIAGNOSIS

    12. ICX Self Diagnoses – Flow

    13. ICX Self Diagnoses – Operat ion

     

    CHANGE PASSWORD

    14. Change Password – Flow

    15. Change Password – Operation

     

    1. Necessary Tools & Cable Connection

    (a) Palm OS PDA (b) Serial cable (c) Dr.ZX communication cable

    Necessary tools

  • 8/18/2019 140396314-Dr-ZX

    118/192

    Cable connection

    Dr.ZX must be ins talled. Hitachi

    recommends following models.

    SONY

    Clie PEG-TJ25

    PalmOne Inc.

    m125 / 130 / 500 / 505 / 515

    Tungsten T2 / T3 / C

    For SONY Clie PEG-TJ25

    Purchase from CPD. P/no. is

    4629330 (Hitachi unique

    parts).

    For PalmOne PDAs

    Purchase from local market.

    Product name is HotSync serial

    This is Hitachi unique part. Make an

    order to your parts ordering channel.

    Hitachi part no. is 4476512.

    Dr.ZX cable Serial cable Palm OS PDA Palm

    Serial cable

    Dr.ZX cable

    Equipment

    Connect to

    Dr.ZX

    connector.

    2. Funct ion

    HMS_LargeMid

    NOTE

    ICX Initializing

    Set Time Difference from GMTSet Local Time

    Synchronize Service-Meter Reading

    Perform this function when

    following cases occur.(a) Deliver new equipment to

    customer.

  • 8/18/2019 140396314-Dr-ZX

    119/192

    Data Downloading

    Data Download

    Save Data Check

    HMS_LargeMid only apply to

    ZX & C series excavators.

    Set Model Code & Serial No.

    Clear ICX Internal Memory

    Change Password

    ICX Self Diagnosis

    (b) Replace ICX.

    (c) Error on downloaded data.

    Perform this function when you

    want to download data from

    equipment.

    Perform this function when

    error(s) on downloaded data.

    Perform this function when you

    want to change password.

    3. ICX Init ializing - How to start Dr.ZX -1/5

    Turn key switch

    “OFF”. 

    Confirm the

    engine-learningswitch is OFF. 

    Connect Dr.ZX to

    equipment. 

    Turn key switch

    “ON”. 

    Switch on Palm. 

  • 8/18/2019 140396314-Dr-ZX

    120/192

    Start Dr.ZX.  Select

    “HMS_LargeMid”

    .

    Select

    “Communication

    Start”.

    Enter password.

    Select

    “Communication

    Start”.

    Select “ICX Initial

    Setting”.

    Tap “Start”.

    Select “Set-ICX”.

    3. ICX Initializing - How to start Dr.ZX -2/5 

    (b) Check Engine learning swi tch i s OFF

    Stamp

    (a) Turn key swit ch “ OFF”

  • 8/18/2019 140396314-Dr-ZX

    121/192

    Hitachi ZAXIS110 & up

    John Deere 120C & up

    Hitachi ZAXIS70, 80, 75US,

    75UR, 135US, 225US

    John Deere 80C, 135CRTS,

    225CCL RTS

    3. ICX Initializing - How to start Dr.ZX -3/5 

    (c) Connect Dr.ZX to equipment.

  • 8/18/2019 140396314-Dr-ZX

    122/192

    Hitachi ZAXIS70, 80, 75US,

    75UR, 135US, 225US

    John Deere 80C, 135CRTS,

    225CCL RTS

    Hitachi ZAXIS110 & up

    John Deere 120C & up

    Connect

    Connect

    3. ICX Initializing - How to start Dr.ZX -4/5 

    (d) Turn key switch “ ON” (f) Start Dr.ZX(e) Switch “ ON” Palm

  • 8/18/2019 140396314-Dr-ZX

    123/192

    Main switch is vary by Palm model. Above shows Palm m500 / 505 / 515.

    Tap “Dr.ZX” icon on Palm.

    NOTE

    Shall not start engine.

    Tap “ ” of “Set-ICX”.Tap “ ” of “Communication Start”.

    (g) Select “ HMS_LargeMid” (h) Select “ Communication Start” (i) Select “ Set-ICX” .

    Tap “ ” of “HMS_LargeMid”.

    3. ICX Initializing - How to start Dr.ZX -5/5 

    (f) Enter password. (g) Tap “ OK”

    TIP

  • 8/18/2019 140396314-Dr-ZX

    124/192

    Tap entering column, and enter password. Default password is

    zx2000.

     After enter password, tap “OK”.

    You can use keyboard to enter 

    password. by tap “abc” or “123” on

    GRAFFITI area.

    (i) Tap “ Start” (j) Select “ ICX Initial Setting”

    Tap “ ” of “ICX Initial Setting”. If “ICX

    Initial Setting “ is not in menu, tap “ ”

    or “ ” to changeover menus.

    (j) ICX initializing menu

    4. ICX Initializing – General Flow  

    NOTE

    Perform ICX initialization on following cases.(a) When delivered new equipment to cus tomer.

    (b) When replaced ICX.

    (c) When error(s) on downloaded data.

  • 8/18/2019 140396314-Dr-ZX

    125/192

    ( ) ( )

    Synchronize

    service meter

    reading.

    Set model code

    & serial no.

    Set local time.Set

    time-difference

    from GMT.

    5. ICX Initializing – Set Time Dif ference from GMT -1/2 

    (a) Select enter Time Diff . from UTC (b) Check current time difference (c) Select time difference

  • 8/18/2019 140396314-Dr-ZX

    126/192

    Tap “ ” of “Enter Time Diff. fromUTC”. If item is not in menu, tap “ ”

    or “ ” to changeover menus.

    Check current time difference. If it iscorrect tap “ESC”, if you want to

    correct, tap “Correct”. Time difference

    table is on next page.

    Tap up-arrow or down-arrow to findcorrect time difference.

    If you find correct time difference, tap

    “OK”.

    (d) Set time difference

    Tap “OK”

    (e) Conf irmation screen

    5. ICX Initializing – Set Time Dif ference from GMT –2/2 

  • 8/18/2019 140396314-Dr-ZX

    127/192

    6. ICX Initializing – Set Local Time -1/2 

    (a) Select Enter Date and Time (b) Check local time

    NOTE

    Please carry out this setting, after 

    set time dif ference from GMT.

  • 8/18/2019 140396314-Dr-ZX

    128/192

    Tap “ ” of “Enter Date and Time”. . If item is not in menu, tap “ ” or “ ” to

    changeover menus.

    Check local time. If it is wrong, tap“Correct” for correction.

    (c) Correct l ocal time

    Tap entering column and enter 

    current local time.

    TIP

    You can use keyboard to enter 

    password. by tap “abc” or “123” on

    GRAFFITI area.

    6. ICX Initializing – Set Local Time -2/2 

    (d) Tap “ OK” (e) Check local time (f) Confirmation screen

  • 8/18/2019 140396314-Dr-ZX

    129/192

     After entering local time, tap “OK”. If local time is correct, tap “OK” for 

    set. If not correct, tap “NG” to

    re-enter.

    Tap “OK”

    7. ICX Initializing – Synchronize Service-meter

    (b) Select Hour Meter Setting (c) Check current service meter (d) Confirmation screen

  • 8/18/2019 140396314-Dr-ZX

    130/192

    Tap “ ” of “Initial Hour Meter 

    Setting”. . If item is not in menu, tap

    “ ” or “ ” to changeover menus.

    If figures are difference, tap “Set” for 

    synchronizing. ICX will set it hour 

    meter as external hour meter.

    Tap “OK”.

    8. ICX Ini tializing – Model Code & Serial No. Sett ing -1/2 

    (b) Select Enter Model & Serial no. (c) Tap “ OK” (d) Tap “ Correct”

  • 8/18/2019 140396314-Dr-ZX

    131/192

    Tap “ ” of “Enter Model and Serial

    No.”. If item is not in menu, tap “ ” or 

    “ ” to changeover menus.

    Even if model code & Serial no. are

    correct, tap “Correct”.

    NOTE-1

    If PIN code is “ HCM 1G600 L 00123456”

    Model code is 1G6.

    Serial no. is 123456.

    TIP

    You can use keyboard to enter 

    password. by tap “abc” or “123” on

    GRAFFITI area.

    (e) Enter model code

    If model code and/or serial no. are incorrect,

    tap column, and enter correct model code

    and/or serial no. Equipment model code &

    serial no. are stamp on name plate.

    NOTE-2

    When entering model code, you have to

    add “0” (zero) in front of model code.

    For example, if model code is 1G6, you

    have to enter 01G6.

    8. ICX Ini tializing – Model Code & Serial No. Sett ing -2/2 

    (h) Internal memory cl ear(g) Confirmation screen(f) Tap “ OK”

  • 8/18/2019 140396314-Dr-ZX

    132/192

    Tap “OK” After correcting, tap “OK”. When initialize ICX, you have to clear 

    ICX internal memory. Otherwise you

    can’t view data in some cases.

    (i) Memory clearing (j) Tap “ OK”

    NOTE

    Shall not download immediately after 

    memory clear, because data is empty

    (Dataviewer could not recognize empty

    data as downloaded data. Operateequipment at least an hour , and

    download data.

    9. Data Downloading – How to Start Dr.ZX -1/5 

    Turn key switch

    “OFF”. 

    Confirm the

    engine-learning

    switch is OFF. 

    Connect Dr.ZX to

    equipment. 

    Turn key switch

    “ON”. 

    Switch on Palm. 

  • 8/18/2019 140396314-Dr-ZX

    133/192

    Start Dr.ZX.  Select

    “HMS_LargeMid”.

    Select

    “CommunicationStart”.

    Select “Data

    Download”.

    Download Menu

    Select “Data

    Download”.

    9. Data Downloading – How to Start Dr.ZX -2/5 

    (b) Check Engine learning swi tch i s OFF

    Stamp

    (a) Turn key swit ch “ OFF”

  • 8/18/2019 140396314-Dr-ZX

    134/192

    ZX110 & up, 120C & up

    ZX70/80/75US/75UR & 80C

    9. Data Downloading – How to Start Dr.ZX -3/5 

    (c) Connect Dr.ZX to equipment.

  • 8/18/2019 140396314-Dr-ZX

    135/192

    ZX110 & up, 120C & up

    Connect

    Connect

    ZX70/80/75US/75UR & 80C

    9. Data Downloading – How to Start Dr.ZX -4/5 

    (d) Turn key switch “ ON” (f) Start Dr.ZX(e) Switch “ ON” Palm

  • 8/18/2019 140396314-Dr-ZX

    136/192

    Main switch is vary by Palm model.

     Above shows Palm m500 / 505 / 515.

    Tap “Dr.ZX” icon on Palm.NOTE

    Shall not start engine.

    Tap “ ” of “Data Download”Tap “ ” of “Communication Start”.

    (g) Select “ HMS_LargeMid” (h) Select “ Communication Start” (i) Select “ Set-ICX” .

    Tap “ ” of “HMS_LargeMid”.

    9. Data Downloading – How to Start Dr.ZX -5/5 

    (d) Download menu

  • 8/18/2019 140396314-Dr-ZX

    137/192

    10. Data Downloading – Download

    Select “Data

    Download”

    Flow

    Select “Data

    Download”

    Quit

    downloading.

    Downloading.

  • 8/18/2019 140396314-Dr-ZX

    138/192

    Download will start automatically after 

    selecting data download. If you want

    to cancel download, tap “Cancel”.

    (a) Select “ Data Download” (b) Downloading

    Tap “ ” of “Data Download”.

    Palm Operation

    Download will start automatically after 

    selecting data download. If you want

    to cancel download, tap “Cancel”.

    (c) Quit download

    11. Data Downloading – Check Downloaded Data 

    Select “Save

    Data Check”.

    Flow

    View data.

  • 8/18/2019 140396314-Dr-ZX

    139/192

    Download data have not uploaded to

    PC will display. Tap “OK” to quit.

    (a) Select “ SaveDataCheck” (b) View data

    Tap “ ” of “SaveDataCheck”.

    Palm Operation

    12. ICX Self Diagnoses – Flow  

    Turn key switch

    “OFF”. 

    Confirm the

    engine-learning

    switch is OFF. 

    Connect Dr.ZX to

    equipment. 

    Turn key switch

    “ON”. 

    Switch on Palm. 

  • 8/18/2019 140396314-Dr-ZX

    140/192

    Start Dr.ZX.  Select

    “HMS_LargeMid”.

    Select

    “CommunicationStart”.

    Enter password.

    Select “ICX

    Diagnosis”.

    If errors are

    shown, tap

    “Retry”.

    Tap “Start”.

    Select “Set-ICX”.

    13. ICX Self Diagnoses – Operation -1/5 

    (b) Check Engine learning swi tch i s OFF

    Stamp

    (a) Turn key swit ch “ OFF”

  • 8/18/2019 140396314-Dr-ZX

    141/192

    ZX110 & up, 120C & up

    ZX70/80/75US/75UR & 80C

    13. ICX Self Diagnoses – Operation -2/5 

    (c) Connect Dr.ZX to equipment.

  • 8/18/2019 140396314-Dr-ZX

    142/192

    ZX110 & up, 120C & up

    Connect

    Connect

    ZX70/80/75US/75UR & 80C

    13. ICX Self Diagnoses – Operation -3/5 

    (d) Turn key switch “ ON” (f) Start Dr.ZX(e) Switch “ ON” Palm

  • 8/18/2019 140396314-Dr-ZX

    143/192

    Main switch is vary by Palm model.

     Above shows Palm m500 / 505 / 515.

    Tap “Dr.ZX” icon on Palm.NOTE

    Shall not start engine.

    Tap “ ” of “Set-ICX”.Tap “ ” of “Communication Start”.

    (g) Select “ HMS_LargeMid” (h) Select “ Communication Start” (i) Select “ Set-ICX” .

    Tap “ ” of “HMS_LargeMid”.

    13. ICX Self Diagnoses – Operation -4/5 

    (f) Enter password. (g) Tap “ OK”

    TIP

    You can use keyboard to enter 

    password. by tap “abc” or “123” on

  • 8/18/2019 140396314-Dr-ZX

    144/192

    Tap entering column, and enter 

    password. Default password is

    zx2000.

     After enter password, tap “OK”.

    GRAFFITI area.

    (i) Tap “ Start” (j) Select “ ICX Diagnosis”

    Tap “ ” of “ICX Initial Setting”. If “ICX

    Initial Setting “ is not in menu, tap “ ”

    or “ ” to changeover menus.

    13. ICX Self Diagnoses – Operation -5/5 

    (f) No error(s) detected

  • 8/18/2019 140396314-Dr-ZX

    145/192

    If errors have not detected, above

    message will display. Tap “ESC” to

    quit.

    Content of error will display. Tap “ ”

    or “ ” to changeover error.

    Tap ”ESC” to quit.

    (g) Error(s) detected

    If any errors have detected, error 

    code will display. Tap “Retry” for 

    confirmation.

    (h) Still error has detected (h) Still error has detected

    If still errors have detected, error 

    code will display. Tap “Detail” to check

    content of each error.

    14. Change Password – Flow  

    Turn key switch

    “OFF”. 

    Confirm the

    engine-learning

    switch is OFF. 

    Connect Dr.ZX to

    equipment. 

    Turn key switch

    “ON”. 

    Switch on Palm. 

  • 8/18/2019 140396314-Dr-ZX

    146/192

    Start Dr.ZX.  Select

    “HMS_LargeMid”.

    Select

    “CommunicationStart”.

    Enter password.

    NOTE

    New password will apply to

    all Dr.ZX functi on.

    Change

    password.

    Tap “Password”.

    Select “Set-ICX”.

    15. Change Password – Operation -1/5 

    (b) Check Engine learning swi tch i s OFF

    Stamp

    (a) Turn key swit ch “ OFF”

  • 8/18/2019 140396314-Dr-ZX

    147/192

    ZX110 & up, 120C & up

    ZX70/80/75US/75UR & 80C

    15. Change Password – Operation -2/5 

    (c) Connect Dr.ZX to equipment.

  • 8/18/2019 140396314-Dr-ZX

    148/192

    ZX110 & up, 120C & up

    Connect

    Connect

    ZX70/80/75US/75UR & 80C

    15. Change Password – Operation -3/5 

    (d) Turn key switch “ ON” (f) Start Dr.ZX(e) Switch “ ON” Palm

  • 8/18/2019 140396314-Dr-ZX

    149/192

    Main switch is vary by Palm model.

     Above shows Palm m500 / 505 / 515.

    Tap “Dr.ZX” icon on Palm.NOTE

    Shall not start engine.

    Tap “ ” of “Set-ICX”.Tap “ ” of “Communication Start”.

    (g) Select “ HMS_LargeMid” (h) Select “ Communication Start” (i) Select “ Set-ICX” .

    Tap “ ” of “HMS_LargeMid”.

    15. Change Password – Operation -4/5 

    (f) Enter password. (g) Tap “ OK”

    TIP

    You can use keyboard to enter 

    password. by tap “abc” or “123” on

    GRAFFITI area

  • 8/18/2019 140396314-Dr-ZX

    150/192

    Tap entering column, and enter 

    password. Default password is

    zx2000.

     After enter password, tap “OK”.

    GRAFFITI area.

    (b) Enter current password(i) Tap “ Password”

    Enter current password. Default

    password is zx2000.

    TIP

    You can use keyboard to enter 

    password. Tap “abc” on GRAFFITI

    are.

    15. Change Password – Operation -5/5 

    (c) Tap “ Execute” (d) Enter new password (e) Tap “ Execute”

  • 8/18/2019 140396314-Dr-ZX

    151/192

    (f) Re-enter new password (g) Tap “ Execute” (h) Tap “ ESC”

    NOTE

    New password will apply to all

    Dr.ZX function.

     

    MIC MiningSuper Large Excavators (EX1200-5 & up) Monitoring System

    Operation Manual

  • 8/18/2019 140396314-Dr-ZX

    152/192

    Operation Manual

    Hitachi Construct ion Machinery Co. Ltd. 

     

    1. Necessary Tools & Cable Connection

    2. Connector Location on Equipment for Monitoring

    3. How to start MIC_Mining

    4. Using CODE by SituationCODE

    5. Code “ SAD-P”

    6. Code “ SAI-P”

    7. Code “ DDL-P”

    8 Code “ MEC-P”

  • 8/18/2019 140396314-Dr-ZX

    153/192

    8. Code MEC P

    9. Code “ SEC-P”

    10. Code “ SEC-P”

     

    1. Necessary Tools & Cable Connection

    (b) HotSync® Serial cable (c) Download cable

    Necessary tools

  • 8/18/2019 140396314-Dr-ZX

    154/192

    Dr.ZX must be ins talled. Hitachi

    recommends following models.

    SONY

    CLIe PEG-TJ25

    PalmOne Inc.

    m125 / 130 / 500 / 505 / 515

    Tungsten T2 / T3 / C

    Purchase from local market. Provide

    cable that adapt to your Palm.

    This is Hitachi unique part. Make an

    order to your parts ordering channel.

    Hitachi part no. is 4486988.

    Palm

    Serial cable

    Download cable

    Equipment

    2. Connector Location on Equipment for Monitoring  

    (a) EX1200-5 (b) EX1200-5C (c) EX1900-5 & up

  • 8/18/2019 140396314-Dr-ZX

    155/192

    3. How to start MIC_Mining – 1/3

    Connect cable to

    equipment.

    Check lamp on

    download cable is off.

    Check jumper

    connector is not

    connecting to cable.

    Turn key switch to off

    position.

    Turn key switch to on

    position.

    Check lamp on

    download cable is

    Start Dr.ZXSwitch on a PDA.

  • 8/18/2019 140396314-Dr-ZX

    156/192

    blinking.

    Start MIC_Mining.

    3. How to start MIC_Mining – 2/3 

    (01) Turn key swit ch “ OFF” (02) Connect cable to equipment

    Connect cable to equipment. Make

    sure that key switch is at of position.Otherwise there is a possibility that

    fuse will burn out.

    (c) Turn key switch “ ON”

    M k th t thi i t d

    (03) Check Jumper connecto r

  • 8/18/2019 140396314-Dr-ZX

    157/192

    Make sure that nothing is connected

    to jumper connector on download

    cable.

    Check lamp on cable is blinking at a

    certain interval.

    (05) Check lamp is blinking

     Above shows PalmOne m500. Switch

    location is vary by model.

    (06) Switch on PDA(c) Turn key switch “ ON”(04) Turn key sw itch “ ON”

    3. How to start MIC_Mining – 3/3 

    Tap “Dr ZX” icon

    (07) Start Dr.ZX

    Tap “ ” of “EPVC Mini”

    (08) Kind menu (09) Main screen

  • 8/18/2019 140396314-Dr-ZX

    158/192

    Tap Dr.ZX icon. Tap of EPVC_Mini .

    Tap home icon.

    (10) Quit MIC_Mining

    4. Using CODE by Situation

    SAD-P Initialize DLUWhen deliver equipment to customer .

    SAI-P Set equipment serial no.

    recorded in DLU & initializing.

    When replace DLU.

  • 8/18/2019 140396314-Dr-ZX

    159/192

    Download data from equipment.

    When data could not view on data viewer. MEC-P

    DDL-P

    Clear DLU internal memory.

    SEC-P

    Check communication line

    between controller & DLU.

    Check communication line

    between sensor & controller.

    CMC-P

    Troubleshooting

    5. Code “ SAD-P” –1/9

    When perform this c ode

    Perform this code, when you deliver equipment to customer. Otherwise DLU would not record monitoring data properly, and also you or

    your customer could not view monitoring data by viewer.

    Flow of this code

    Set service meter

    reading.

    Check equipment serial

    no. recorded in Data

    logger.

    Set local date & time.Set time difference from

    GMT.

  • 8/18/2019 140396314-Dr-ZX

    160/192

    Clear memory in data

    logger.

    Check information

    recorded in data logger.

    Confirmation

    5. Code “ SAD-P” –2/9 

    Tap “SettingAdjustment” in toolsTap menu icon.Tap “ ” to set time difference

    (01) Set time dif ference (02) Date & Time adjustment (03) Date & Time adjustment

  • 8/18/2019 140396314-Dr-ZX

    161/192

    Tap SettingAdjustment in tools

    menu.

    Tap menu icon.Tap to set time difference

    between GMT. List of time difference

    is at Code “SAD-P” –9/9.

    Enter name of person who will set

    date & time at name column, and

    enter clock at work code column.

    (04) Date & Time adjustment

    TIP

    You can use keyboard to enter 

    password. Tap “abc” or “123” on

    GRAFFITI area.

    Tap “Next”.

    (05) Date & Time adjustment

    5. Code “ SAD-P” –3/9 

    Date & time current recorded in DLU

    (06) Date & Time adjustment

    Tap “Date”.

    (07) Date & Time adjustment te

    Tap “Today”. Date & year will set

    (08) Date & Time adjustment

  • 8/18/2019 140396314-Dr-ZX

    162/192

    will display. If you have to adjust, tap“Change”, if no need to change, tap

    “Set”.

    p p y y

    automatically. Before setting date,confirm date on Palm is same as

    local.

    Tap “Time”.

    (09) Date & Time adjustment

    Tap hour and adjust to local by

    tapping “ ” “ ”.

    (10) Date & Time adjustment

    Tap minute and adjust to local by

    tapping “ ” “ ”.

    (11) Date & Time adjustment

    5. Code “ SAD-P” –4/9 

    Tap minute and adjust to local by

    (12) Date & Time adjustment

    If date & time are same as local, tap

    (13) Date & Time adjustment

    Message will display. Tap “Ok” to set

    (14) Date & Time adjustment

  • 8/18/2019 140396314-Dr-ZX

    163/192

    Tap “SettingAdjustment” in tools

    menu.

    Main screen Tap menu icon.

    tapping “ ” “ ”. “Set”. date & time. Tap “Back” to correctdate & time.

    (15) Servic e meter adjustment (16) Service meter adjustment (17) Service meter adjustment

    5. Code “ SAD-P” –5/9 

    Enter name of person who will set

    (18) Service meter adjustment

    TIP

    You can use keyboard to enter password. Tap “abc” or “123” on

    GRAFFITI area.

    Tap “Next”.

    (19) Service meter adjustment

  • 8/18/2019 140396314-Dr-ZX

    164/192

    service meter at name column, andenter run at work code column.

    If service meter reading is not match

    to equipment, tap “Change”.

    (20) Service meter adjustment

    Tap “ ” “ ”, and adjust service

    meter reading to actual equipment.

    (21) Service meter adjustment (22) Service meter adjustment

    5. Code “ SAD-P” –6/9 

    Main screen Tap menu icon.Message will display. Tap “Ok” to set

    (23) Servic e meter adjustment (24) Serial no. check (25) Serial no. check

  • 8/18/2019 140396314-Dr-ZX

    165/192

    Tap “SettingAdjustment” in tools

    menu.

    service meter reading. Tap “Back” tocorrect service meter reading.

    (26) Serial no. check

    Enter name of person who will check

    serial no. at name column, and e