D102 D108 D101 D103 D104 D105 D106 D107 ATC - Office OC F01 Storage F04 Stairwell F02 ATC - Orderly F03 Classroom (ACF) F05 Classroom (shared) F06 Classroom (ATC) F07 Radio Room F08 Corridor F09 W103 W102 W101 W108 W107 W106 W105 W104 02 02 03 03 04 04 05 05 01 01 B B C C D D E E A A A:A 108 B:B 108 8600mm 130mm 130mm 130mm 130mm 130mm 100mm C:C 109 D:D 109 roof pitch 25 degrees roof pitch 25 degrees RWP RWP 250mm 250mm 130mm 5322mm E:E 110 RWP RWP RWP 01 106 South Elevation 107 East Elevation 02 North Elevation 01 107 106 West Elevation 02 540mm 1500mm 4560mm 140mm 140mm 864mm 625mm 490mm 2250mm 1360mm 140mm 140mm 1500mm 140mm 861mm 1500mm 140mm 140mm 140mm 510mm 1500mm 2210mm 140mm 2260mm 1500mm 140mm 140mm 140mm 1890mm 1500mm 1695mm 2679mm 42mm 2682mm 832mm 1493mm 750mm 3361mm 2432mm LIFT 1446mm 130mm 1493mm 1500mm 6600mm 1100mm 4221mm 4100mm 5720mm 5280mm 4220mm 4100mm 140mm 140mm 540mm Clear 1615mm Void W1 W4 W3 Date: Scale: Drawn by: Checked by: Drawing title: Client: Project: Notes: Chkd By Date Rev Notes Proposed First Floor Layout Reserve Forces & Cadets Association Joint Cadet Centre Tottenham File Ref: (internal use only) Drawing no: Rev: 13010-02-104 C Do not scale dimensions from this drawing. Dimensions marked with an asterisk thus * are open site dimensions to be confirmed on site. All given dimensions are to be checked on site when setting out and any discrepancy reported immediately. 03.02.14 1:50@A1 sa spc c01 A 14/3/14 Design development sa spc General updates to layout and lift specification B 27/3/14 sa spc Updates for tender C 10/6/14 spc gdw KEY: Proposed First Floor Layout 1:50@A1 1 Line to indicates external face of external wall below NOTE: Drawings to be read in conjuntion with BPR specification 13010-02-sch03 NOTE: All setting out taken from gridline to: - Centreline of concrete infill to external walls. - Face of blockwork for internal partitions. NOTE: For door and ironmongery schedule refer to BPR document 13010-02-sch06 13010-02 Hazard Notes Please be aware of the following Hazards have been identifed in relation to the works shown on this drawing ID Hazard Action 1 Works at Height Principle Contractor to ensure appropriate barriers, guarding are in place and minimise heavy lifting where possible. PC to provide method statement accordingly. 2 Access to roof Provide safe access to roof. Ensure appropriate barriers, guardings are in place to work safely. Principle contractor to provide method statement accordingly 3 Roof finish vunerable to damage during works Protect roof finish at all times Wall Type 1A (W1A) 280mm ICF external wall construction with brick slips. Spec Ref: 25-15-35/140 20-00-75/185 Pitched roof structure Blue dashed line indicates structural gridlines Wall Type 4 (W4) 158mm internal metal stud partition (to underside of roof soffit) Spec Ref: 25-15-25/135 NOTE: All metal stud partitions to first floor are W4 type. Rainwater pipe Spec Ref: 50-10-00/110 Indicates proposed location of steel beams. Refer to SE drawings and specification for details Wall Type 3 (W3) 106mm internal metal stud partition Spec Ref: 25-15-25/135 NOTE: For full scope of internal finishes refer to BPR document 13010-02-sch07 Dashed line to indicate proposed location of steel supporting structure. Refer to SE drawings for details