HLT-07 RO NRC EXAM
1.201001K1.11001 -•
The Unit 2 reactor is operating at 100% power with the following
indications present on panel2H1 1-P603:
o Charging Water Pressure 1480 psigo Cooling Water dP 0 psido
Drive Water dP Upscaleo Drive Water Flow 0 gpmo Cooling Water Flow
5 gpm
With the above indications, which ONE of the choices below
completes the followingstatements?
The CRD has been fully closed.
RWCU Seal Purge flow
__________
isolated?
A. Flow Control Valve, 2C1 1-FOO2A;is
B. Flow Control Valve, 2C11-FOO2A;is NOT
C. Drive Water Pressure Control Valve, 2C1 1-F003,is
D. Drive Water Pressure Control Valve, 2C1 1-F003,is NOT
1
-
HLT—07 RO NRC EXAM
2. 202001A1.02 001
Which ONE of the choices below completes the following
statements concerning monitoringUnit 2 INDIVIDUAL jet pump flows
and a potential problem associated with a jet pump failureduring a
Loss of Coolant Accident (LOCA)?
If jet pump #3 failure were to occur during plant operation, the
INDIVIDUAL failed jetpump dP can be monitored on panel
A catastrophic failure of jet pump #3 will be indicated by
A. 2H11-P602;a sudden INCREASE in reactor power
B. 2H11-P602;a sudden REDUCTION in jet pump differential
pressure
C. 2H11-P619;a sudden INCREASE in reactor power
D. 2H11-P619;a sudden REDUCTION in jet pump differential
pressure
2
-
HLT-07 RO NRC EXAM
3. 202002K3.03 001
Unit 2 is operating at 100% RTP when a malfunction causes a
Recirc runback signal to SpeedLimiter #1 on BOTH Recirc Pumps.
Which ONE of the choices below completes the following
statements?
While the Recirc Pumps are reducing speed, INDICATED reactor
water level on2C32-R606A, B and C, Narrow Range instruments
will
__________
The FINAL Recirc Pump speed will be
__________
A. decrease;22%
B. decrease;33%
C. increase;22%
D. increase;33%
3
-
HLT—07 RO NRC EXAM
4. 203000G2.4.34 001
An event occurred on Unit 2 requiring control to be transferred
to the Remote Shutdown Panel(RSDP).
o ALL Emergency Transfer Switches have been placed to the
“EMERGENCY Positiono Subsequently, a LOCA signal is received and
Reactor pressure decreases to 90 psig
Which ONE of the choices below completes the following statement
concerning Unit 2 RHRLPCI Injection from the RSDP?
Placing the Emergency Transfer Switches, for the RHR pump(s)
controlled from the RSDP,to the “EMERGENCY” Position
__________
The LPCI injection path associated with the above pump(s)
A. will NOT defeat the auto start function for the pump(s);must
be MANUALLY aligned to inject into the RPV
B. will NOT defeat the auto start function for the pump(s);will
AUTOMATICALLY align to inject into the RPV
C. will defeat its auto start function for the pump(s);must be
MANUALLY aligned to inject into the RPV
D. will defeat its auto start function for the pump(s);will
AUTOMATICALLY align to inject into the RPV
4
-
HLT-07 RO NRC EXAM
5. 204000K4.01 001
Unit 2 is at operating at RTP when a malfunction occurs causing
the following conditions:
o RWCU HX room temperature and pump room temperatures peaked at
125°Fo RWCU differential flow reached 60 gpm for 30 seconds then
went to 0 gpm (indicated)o Non-Regenerative HX (NRHX) outlet
temperature peaked at 125°Fo ‘2W RWCU pump cooling water
temperature peaked at 145°Fo The “2W’ RWCU pump tripped
Based on these conditions, which ONE of the choices below is the
reason the”2B” RWCU pumptripped?
The “2B” RWCU pump tripped because of high
A. differential flow
B. pump room temperature
C. pump cooling water temperature
D. Non-Regenerative HX (NRHX) outlet temperature
5
-
HLT-07 RO NRC EXAM
6. 205000K5.02 001
Unit 2 is shutdown with the following conditions:
o A’ ioop of RHR is in Shutdown Cooling (SDC)o 2E1 1-F008, SDC
Suction Vlv, is OPENo 2E1 1-F009, SDC Suction Vlv, is OPENo 2E1
1-FO15A, RHR Inbd Inj Vlv, is OPENo Reactor pressure is 125 psig
and steady
o Subsequently, 2E1 1-F048A, Hx Bypass valve, fails full OPEN
and cannot be re-closedo Reactor pressure starts increasing at 1
psig/minute
Without any operator actions and based on the above conditions,
which ONE of the choicesbelow completes the following
statements?
When Reactor pressure reaches 140 psig, RHR Valves,
___________
will be CLOSED.
The RHR pumps
________
receive a trip signal as a result of these valve closures.
A. 2E1 1-F008 and 2E1 l-F009 (ONLY);will
B. 2E1 1-F008 and 2E1 1-F009 (ONLY);will NOT
C. 2E11-F008, 2E11-F009 and 2E11-FO15A;will
D. 2E11-F008, 2E11-F009 and 2E11-FO15A;will NOT
6
-
HLT-07 RO NRC EXAM
7. 206000K5.06 001
The Unit 2 Shift Supervisor has established operation at the
Remote Shutdown Panel due toControl Room evacuation.
Currently Unit 2 reactor water level is -30 inches and reactor
pressure is 1000 psig.
The HPCI system is operating with the following parameters:
o HPCI turbine speed = 3000 rpmo HPCI pump discharge pressure =
780 psig
An operator makes an adjustment locally, which results in the
HPCI turbine speed increasing to5050rpm.
After the operator makes the adjustment, which ONE of the
choices below completes thefollowing statement?
The operator is using a
___________
to monitor HPCI turbine speed and the HPCI turbine
_______
have tripped.
A. locally mounted gauge;should
B. locally mounted gauge;should NOT
C. strobe tachometer;should
D. strobe tachometer;should NOT
7
-
HLT-07 RO NRC EXAM
8. 209001K1.12 001
A transient has occurred on Unit 2.
At 10:00 the following conditions exist:
o Drywell pressure 0.7 psigo Reactor water level -95 inches
decreasing 2 inches/minuteo Reactor pressure 500 psig decreasing 2
psig/minuteo 2A Core Spray pump is MANUALLY started
Which ONE of the choices below completes the following
statements?
At 10:01, the number of CS/RHR Pump Room Coolers operating
is
__________
At 10:05,
__________
CS/RHR Pump Room Coolers will be operating.
A. zero (0);ONLY two (2)
B. zero (0);ALL four (4)
C. two (2);ONLY two (2)
D. two(2);ALL four (4)
8
-
HLT-07 RO NRC EXAM
9. 209001K5.O1 001
A LOCA is in progress. The 2A Core Spray pump is injecting at
1000 gpm to maintain RPVwater level above the top of active
fuel.
Which ONE of the following would be an indication that the 2A
Core Spray pump isexperiencing cavitation?
A. The motor amps are steadily increasing.
B. The pump trips due to low suction pressure.
C. The minimum flow valve intermittently opens and closes.
D. The pump discharge pressure steadily increases as flow
decreases.
9
-
HLT-07 RO NRC EXAM
10. 211000K4.02 001
Unit 2 is operating at 100% RTP with the 2B SBLC pump
inoperable.
o The 2B SBLC pump breaker is Danger Tagged OPEN
The crew has just been tasked with performing 34SV-C41-002-2,
Standby Liquid Control PumpOperability Test, for the 2A SBLC
pump.
Which ONE of the choices below completes the following statement
concerning the SquibValve Continuity lights on the 2H11-P603 panel
and the RWCU System?
After the operator locally starts the 2A SBLC Pump,
A. two (2) Squib Valve Continuity lights on the 2H1 l-P603 panel
will be ILLUMiNATED andthe RWCU System WiLL isolate
B. two (2) Squib Valve Continuity lights on the 2H1 1-P603 panel
will be ILLUMINATED andthe RWCU System WILL NOT isolate
C. ONLY one (1) Squib Valve Continuity light on the 2H11-P603
panel will beILLUMINATED and the RWCU System WILL isolate
D. ONLY one (1) Squib Valve Continuity light on the 2H1 1-P603
panel will beILLUMINATED and the RWCU System WILL NOT isolate
10
-
HLT-07 RO NRC EXAM
11. 212000A2.08 001
Unit 2 is in Mode 4 with RHR Shutdown Cooling in service.
An event occurs causing RWL to decrease and results in the
following:
o 2C32-R606A-C GEMAC (+) 2 inches (LOWEST level reached)
o Subsequently, the NPO recovers RWL to (+) 20 inches
Which ONE of the choices below completes the following
statements?
During this event, the RPS RWL Scram Setpoint
__________
EXCEEDED.
34AB-E1 1-001-2, Loss Of Shutdown Cooling,
__________
REQUIRED to be entered.
A. was;is NOT
B. was;is
C. was NOT;is NOT
D. was NOT;is
11
-
HLT—07 RO NRC EXAM
12. 212000K3.03 001
Unit 2 is operating at 100% RTP when a loss of RPS Bus 2A
occurs.
Which ONE of the choices below describes the affect of losing
RPS Bus 2A on the LPRMs?
A. ONLY Half of the LPRMs inputs associated with APRMs 2B &
2D are still VALID.
B. ONLY Half of the LPRMs inputs associated with APRMs 2A &
2C are still VALID.
C. NONE of the LPRMs inputs associated with APRMs 2B & 2D
are still VALID.
D. ALL of the LPRMs inputs associated with APRMs 2A & 2C are
still VALID.
12
-
HLT-07 RO NRC EXAM
13. 215002K6.04 001
Unit 2 is operating at 100% power with a centrally located
control rod selected.
o The operator bypasses APRM channel “A” due to bad CPU
Which ONE of the choices below identifies the effect this action
will have on the RBM ‘A”channel?
RBM “A” will automatically use the
A. “C” APRM channel to monitor the neutron flux in the locality
of the selected rod
B. “C” APRM channel to determine one of the three upscale
setpoints
C. “D” APRM channel to monitor the neutron flux in the locality
of the selected rod
D. “D” APRM channel to determine one of the three upscale
setpoints
13
-
HLT-07 RO NRC EXAM
14. 215003A1.06 001
Unit 1 is in Startup with IRM lA! indicating 50 on Range 4. ALL
other IRMs are readingMid-scale on their respective range.
The NPO momentarily positions IRM IA Range switch to Range 3 and
then back to Range 4.
Which ONE of the choices below completes the following
statements?
With IRM ‘lA” on Range 3,
_________
and 603-238, ROD OUT BLOCK, will be in thealarm condition.
Once IRM ‘lA” is returned to Range 4, the IRM ‘lA” will be
EXTINGUISHED.
A. annunciators 603-221, IRM UPSCALE, 603-203, IRM BUS A UPSCALE
TRIP OR INOP;
Drawer UPSC amber light on 1H1 1—P606
B. annunciators 603-221, IRM UPSCALE, 603-203, IRM BUS A UPSCALE
TRIP OR INOP;
UPSC amber light on the benchboard (horizontal portion) of lHl
l-P603
C. ONLY annunciators 603-221, IRM UPSCALE;
UPSC amber light on the benchboard (horizontal portion) of 1H1
1-P603
D. ONLY annunciators 603-221, IRM UPSCALE;
Drawer UPSC amber light on 1H1 1-P606
14
-
HLT-07 RO NRC EXAM
15. 215004K6,02 001
Unit 1 is starting up.
o Reactor Water Level (+) 37 Incheso The reactor is criticalo
IRMs are all on-scale on Range 3
A loss of 24/48 VDC “IB”, 1R25-S016, occurs.
Which ONE of the choices below will occur as a result of this
power loss?
Source Range Monitor (SRM)__________ indicator will fail
__________
A. ‘iC”;as is
B. ‘iC”;downscale
C. “lD”;as is
D. ‘iD”;downscale
15
-
HLT—07 RO NRC EXAM
16. 215005A1.01 001
Unit 2 is at 9% RTP when the following occurs:
o LPRM 44-21A fails UPSCALE (Inputs into APRM 2Dh)o
Subsequently, Operations bypasses the failed LPRM
The following represents the status of APRM “2D’ fiçr LPRM
44-21A is bypassed:
o Number of Level D LPRM Inputs ... 6o Number of Level C LPRM
Inputs ... 4o Number of Level B LPRM Inputs ... 5o Number of Level
A LPRM Inputs ... 2
Which ONE of the choices below completes the following
statements?
When LPRM 44-21A failed upscale, APRM “2D” power indication
_________
After LPRM 44-21A is bypassed, APRM “2D is inoperable because
there aretoo few
_________
A. remained the same;total LPRM inputs
B. remained the same;LPRM inputs per level
C. increased;total LPRM inputs
D. increased;LPRM inputs per level
16
-
HLT-07 RO NRC EXAM
17. 215005A4.03 001
Unit 1 is operating at 100% RTP when 603-210-1, APRM/OPRM TRIP,
alarm comes in andthen immediately clears due to a momentary
failure of one (1) APRM.
Which ONE of the choices below completes the following
statements?
With the above condition, a RPS Half Scram signal
__________
have been received.
If the APRM is bypassed, the TOTAL number of 2/4 Logic modules
(Voters) that will havethe associated APRM’s bypass light
ILLUMINATED is
__________
A. would;two (2)
B. would;four (4)
C. would NOT;two (2)
D. would NOT;four (4)
17
-
HLT-07 RO NRC EXAM
18. 216000A4.01 001
A transient has occurred on Unit 2 resulting in Reactor Water
Level (RWL) decreasing.
A RWL Milestone is established at -175 inches.
Subsequently, an Emergency Depress is performed.
A Normal RWL band of (+) 32 to (+) 42 inches is established.
Which ONE of the choices below completes the following statement
for determiningACCURATE RWL?
To determine when the -175 inch Milestone is reached, the NPO
will be monitoring RWL atpanel 2H1 1-
__________
to determine when RWL is in its Normal band.
A. P601 and then transition to the 2H1 1-P603 panel
B. P601 and continue monitoring at the 2H1 1-P601 panel
C. P602 and then transition to the 2H1 1-P603 panel
D. P602 and continue monitoring at the 2H1 1-P602 panel
18
-
HLT-07 RO NRC EXAM
19. 217000K2.04 001
Which ONE of the choices below is the power supply to RCIC
Barometric Condenser VacuumPump, 2E5 1 -C002-2?
A. 1251250V DC SWGR 2C, 2R22-S018
B. 125/250V DC SWGR 2D, 2R22-S019
C. 250V DC MCC 2A, Reactor Building Feeder, 2R24-S021
D. 125V DC DIST. CAB. 2D, ESS DIV I, 2R25-S 129
19
-
HLT-07 RO NRC EXAM
20. 218000K1.04 001
Unit 2 has experienced a Loss of Offsite Power (LOSP).
The following conditions existed at 15:00:
o ALL low pressure ECCS pumps have been manually startedo RPV
Pressure 860 psig controlled by LLSo RWL -97 inches, decreasing at
2 inches/minuteo Drywell Pressure 1.0 psig, increasing at 0.3
psi/minuteo ADS Inhibit Switches “Normal’ position
Given these trends, which ONE of the following predicts the
EARLIEST time that the ADSvalves will have automatically
OPENED?
A. 15:03
B. 15:06
C. 15:13
D. 15:15
20
-
HLT-07 RO NRC EXAM
21. 223001A3.04 001
A LOCA has occurred on Unit 2 resulting in Drywell pressure
increasing to 20 psig.
Subsequently, Drywell Sprays are placed in service and Drywell
pressure is reduced to 1.0 psig.
Which ONE of the choices below completes the following
statements?
The Drywell I Torus Vacuum Breakers will automatically cycle
while Drywell pressure is
Monitoring for proper automatic operation of the Drywell / Torus
Vacuum Breakers can beperformed from
__________
A. increasing to 20 psig;panel 2H1 1-P602 AND locally at panel
2T48-P001
B. increasing to 20 psig;panel 2H 11 -P602 ONLY
C. decreasing to 1.0 psig;panel 2H1 1-P602 AND locally at panel
2T48-P001
D. decreasing to 1.Opsig;panel 2H1 1-P602 ONLY
21
-
HLT-07 RO NRC EXAM
22. 223002K3.10 001
Unit 2 is at 100% power and the T2A’ Reactor Protection System
(RPS) M/G Set trips.
Which ONE of the choices below completes the following
statement?
After RPS M/G Set “2A” trips, the operating Reactor Water
Cleanup pump
A. will AUTOMATICALLY trip due to suction valve closure
B. will AUTOMATICALLY trip due to low suction pressure
C. must be MANUALLY tripped due to suction valve closure
D. must be MANUALLY tripped due to low suction pressure
22
-
HLT-07 RO NRC EXAM
23. 233000K2.02 001
Unit 1 is in Mode 4 with 1BI and ‘iD’ Residual Heat Removal
(RHR) pumps running inShutdown Cooling with Fuel Pool Cooling
Assist in service.
o A condition develops on Emergency Bus 416OVAC “iF” which
causes it to de-energize
Which ONE of the following predicts the status of the “IB” and
“iD” RHR pumps?
A. “lB’ RHR Pump has stopped“iD’ RHR Pump has stopped
B. “lB’ RHR Pump is running‘iD” RHR Pump has stopped
C. “iB” RHR Pump has stopped‘iD” RHR Pump is running
D. “lB’ RHR Pump is running“iD’ RHR Pump is running
23
-
HLT-07 RO NRC EXAM
24. 234000K5.02 001
Unit 2 is in a refueling outage with the following
conditions.
o Rx Mode Switch Locked in the REFUEL positiono Control rods One
control rod is fully WITHDRAWNo Main Fuel Grapple Lowered, but
verified to be able to clear the cattle chute by 3 ft.
(Empty grapple move)o NO rod is selected
The Refuel Bridge is over the Spent Fuel Pool and is moving
toward the core to pick up the fuelbundle at position 17-42.
Which ONE of the following choices completes the following
statements concerning how therefueling interlocks will respond?
With these conditions, the Refuel Bridge
___________
move to the intended core location.
When the Refuel Bridge stops, if the Grapple Raise/Lower switch
is placed in the “LOWER’position, the Main Grapple
___________
lower.
A. will;will
B. will;will NOT
C. will NOT;will
D. will NOT;will NOT
24
-
HLT-07 RO NRC EXAM
25. 239002A3.02 001
Unit 2 experienced a Group One from 100% power.
Eight (8) SRV amber lights are illuminated and “B’ SRV is
currently open with reactor pressureat 875 psig.
Which ONE of the choices below is the LOWEST reactor pressure
which must have beenreached to cause these conditions?
A. 1080 psig
B. ll2Opsig
C. ll3Opsig
D. ll4Opsig
25
-
HLT-07 RO NRC EXAM
26. 241000A2.23 001
Unit 2 is operating at 23% reactor power.
The Main Turbine/Generator has just been tied to the grid.
Subsequently, 650-136, Vibration Alarm, is received.
Investigation reveals that Turbine Eccentricity is 3 mils and
Vibration is 14 mils and has been atthese values for the last 2
minutes.
Which ONE of the choices below completes the following
statements?
JAW 34S0-N30-0O1-2, Main Turbine Operation, the
__________
is required to be used formonitoring Eccentricity on the Main
Turbine.
To CLOSE the Main Turbine Stop Valves, the NPO will
__________
on 2H1 1-P650 panel.
A. 2N32-R609, “TURBINE METAL EXPANSION/TEMP” recorder;select the
“Close Valves” button on the “Control” -“Speed” Screen
B. 2N32-R609, “TURBINE METAL EXPANSION/TEMP” recorder;depress
the Turbine Trip pushbuttons
C. Human Machine Interface (HMI) Screen;select the “Close
Valves” button on the “Control” -“Speed” Screen
D. Human Machine Interface (HMI) Screen;depress the Turbine Trip
pushbuttons
26
-
27. 259002A4.07 001
HLT-07 RU NRC EXAM
Unit 2 is at 60% power removing the “B” RFPT from service with
the following conditions:
o “A” RFPT is in Auto, controlled from the FW Master Controller
2C32-R600o “B” RFPT is in Manual, as indicated below on M/A
station, 2C32-R6O1Bo NO other switches have been repositioned
With the “B” RFPT controller in “Manual”, which ONE of the
choices below completes thefollowing statements?
The “B” RFPT will be used to lower “B” RFPT flow.
Depressing the “B” RFPT “PF” key will
A. speed setter switch;lower the “B” RFPT setpoint by 4
inches
B. speed setter switch;change the “Green” bar display to
“Controller Output”
C. output lever;lower the “B” RFPT setpoint by 4 inches
D. output lever;change the “Green” bar display to “Controller
Output”
RFP B M?A STATION
27
-
HLT-07 RO NRC EXAM
28. 261000A1.01 001
Unit 2 is operating at 100% RTP.
At 10:00, an event occurs resulting in Unit 2 Drywell pressure
increasing to and stabilizingat 2.5 psig.
Which ONE of the choices below completes the following
statements?
At 10:15, with NO operator actions, the TOTAL amount of Unit 2
SBGT System flow goingto the Main Stack is expected to be
between
__________
SCFM.
Unit 2 SBGT flow can be monitored on panels 2H11-P654 &
__________
A. 3000 and 4000;2H1 1-P657
B. 3000 and4000;2H1 1-P700
C. 6000 and 8000;2H1 1-P657
D. 6000 and 8000;2H1 1-P700
28
-
HLT-07 RO NRC EXAM
29. 261000K3.02 001
Unit 2 is operating at 100% RTP with the following
conditions:
o Unit 2 Refueling Hatch installedo 2A Standby Gas Treatment
(SBGT) Fan is Danger Tagged out for maintenance
Subsequently, the following occurs at the listed times:
10:00 A RWCU System break in the Unit 2 Reactor Building10:05
2Dl 1-K609A-D, Rx. Bldg. Contaminated Area Radiation increase to 20
mr/hr10:10 The Supply breaker for 2R24-S012, 600V MCC, trips
OPEN
With NO operator action, which ONE of the choices below predicts
how the Off-siteRadioactive Release Rates will be affected?
At 10:08, the Reactor Building Stack release rate will be
_________
than at 10:04.
At 10:15, the Main Stack release rate will be
__________
at 10:08.
A. higher;approximately the same as
B. higher;lower than
C. lower;approximately the same as
D. lower;lower than
29
-
HLT-07 RO NRC EXAM
30. 26200 1G2.4.47 001
WHITE LIGHTS
A. running, but is NOT tied to 4160 VAC 1E bus
B. running and IS tied to 4160 VAC 1E bus
C. NOT running, but can be manually started from the control
room
D. NOT running and can NOT be started from the control room
A LOSP has occurred on Unit 1.
The operator notices the following indications on panel 1H1
1-P652 for 416OVAC 1E bus and itsassociated Diesel Generator
(DG):
o LOSP 86 lockout TRIPPEDo Normal and Alternate supply breakers
OPENo Auto Start System Operative light EXTINGUISHED
BLUE LIGHTS(EXTINGUISHED)
VOLT SELECT 1
Which ONE of the choices below completes the following
statement?
The DG associated with 416OVAC 1E bus is
__________
30
-
HLT-07 RO NRC EXAM
31. 262002A3.01 001
Unit 2 is at 100% power when the following occurs:
o Loss of OffSite Power (LOSP)o !2A1? EDG fails to start
Which ONE of the below choices completes the following
statements?
After the LOSP, the Unit 2 Vital AC Bus will INITIALLY receive
power from
________
Three (3) hours later and without any operator actions, the
Vital AC Busautomatically transfer to ANOTHER power source.
A. the Vital AC batteries;will
B. the Vital AC batteries;will NOT
C. 600 V Bus 2D via Vital AC battery charger;will
D. 600 V Bus 2D via Vital AC battery charger;will NOT
31
-
HLT-07 RO NRC EXAM
32. 263000A2.02 001
Unit 2 is operating at 100% power, with the “2A” and “2B”
125/25OVDC Station ServiceBatteries on equalize charge.
o All Control Building Chillers and fans trip and can NOT be
restoredo Control Building temperatures start increasing
Which ONE of the following completes both statements concerning
the effect of charging thebatteries with the above conditions
present and any required actions to mitigate theconsequences of the
event?
With the above conditions,
__________
To mitigate the consequences of this event, the operator will
enter
A. Hydrogen concentration will rise in the battery rooms;
34AB-T41-001-2, ‘Loss Of ECCS, MCREC Or Area Ventilation
Systems” and startEmergency Exhaust Fans 2Z41-C014 and
2Z41—C015
B. Hydrogen concentration will rise in the battery rooms;
34SO-R42-001-2, “125 VDC AND 125/250 VDC SYSTEM”, and secure all
the batterychargers
C. the Battery Chargers will trip when their high temperature
trip setpoint is reached;
34AB-T41-001-2, “Loss Of ECCS, MCREC Or Area Ventilation
Systems” and startEmergency Exhaust Fans 2Z41-C014 and
2Z41-C015
D. the Battery Chargers will trip when their high temperature
trip setpoint is reached;
34SO-R42-001-2, “125 VDC AND 125/250 VDC SYSTEM”, and secure all
the batterychargers
32
-
HLT-07 RO NRC EXAM
33. 264000K4.06 001
Unit 2 is operating at 100% RTP with 34SV-R43-003-2, Diesel
Generator 2C Monthly Test, inprogress.
Diesel Generator 2C is loaded to 1800 kW.
Which ONE of the choices below completes the following
statements concerning operation ofthe Speed Droop and the Load
Limit knobs? (Answer each part independently of each other)
If the Speed Droop Knob on Diesel Generator 2C is slowly turned
to the zero (0) position,Diesel Generator 2C
_________
shutdown.
Slowly turning the Load Limit knob on Diesel Generator 2C to the
zero (0) position,
A. will NOT;will completely shut off the fuel oil supply to
Diesel Generator 2C
B. will NOT;will decrease the load to “0” kW and Diesel
Generator 2C will continue to run
C. will;will completely shut off the fuel oil supply to Diesel
Generator 2C
D. will;will decrease the load to “0” kW and Diesel Generator 2C
will continue to run
33
-
HLT-07 RO NRC EXAM
34. 268000A4.01 001
JAW 34SV-SUV-019-2, Surveillance Checks, and TS 3.4.4, RCS
Operational LEAKAGE,which ONE of the choices below identifies the
integrator used in determiningUNIDENTIFIED! Leakage rate and its
location?
A. Drywell Floor Drain Sump Integrator, 2G1 1-K601, located on
panel 2H11-P602.
B. Drywell Floor Drain Sump Integrator, 2G1 l-K601, located on
panel 2H1 l-P613.
C. Drywell Equipment Drain Sump Integrator, 2G1 l-K603, located
on panel 2H11-P602.
D. Drywell Equipment Drain Sump Integrator, 2G11-K603, located
on panel 2H11-P613.
34
-
HLT-07 RO NRC EXAM
35. 286000G2.4.9 001
Unit 1 experiences a LOCA and LOSP with ALL Unit 1 Emergency
Diesel Generators failing tostart and cannot be manually
started.
The following conditions exist on Unit 1:
o Reactor water level -160 inches, decreasing 2 inches/minuteo
Reactor pressure 25 psig, slowly lowering
31E0-EOP-1 10-1, Alternate RPV Water Level Control, is in
progress.
With the above conditions, which ONE of the choices below
completes the following statementsconcerning Fire Water Injection
into the Residual Heat Removal (RHR) System?
JAW 31E0-EOP-1 10-1, Alternate RPV Water Level Control, the Fire
System can be usedfor RPV injection by aligning it
___________
The MAXIMUM number of Fire Pumps that can be started is
__________
A. INDIRECTLY into the RHR System via the Condensate Transfer
System piping;two (2)
B. INDIRECTLY into the RHR System via the Condensate Transfer
System piping;three (3)
C. DIRECTLY into the RHR System piping;two (2)
D. DIRECTLY into the RHR System piping;three (3)
35
-
36. 295001AK2.01 001
HLT-07 RO NRC EXAM
Unit 2 is operating at 73% power with both Recirc Pumps
operating at 70% speed when the2A Recirc Pump trips.
After conditions stabilize, 2B21-R613, Core Plate DpIRx Core
Flow, indicates as shown onFigure 1 below:
With NO operator action, which ONE of the choices below
completes the following statements?
The flow through the “A” Loop Jet Pumps is depicted in
__________
The % Rated Core flow indicated on Figure 1 for 2B21-R613, Core
Plate DpIRx Core Flow,
_________
of actual Core flow.
A. Figure 2;is an accurate indication
B. Figure 2;is NOT an accurate indication
C. Figure 3;is an accurate indication
D. Figure 3;is NOT an accurate indication
CORE PLATE dpIRX CORE FLOW2B21-R613
“A” ,eire Pump 13” Recite Pump
Figure 2Coolant Flow
Direct in,,
“A” Recite Pump “13” Recite Pump
Coolant I low —Direction Figure 3
36
-
HLT-07 RO NRC EXAM
37. 295003AK1.03 001
Unit 2 is operating at 100% RTP when the following occurs on
4160V Bus 2G:
o Normal Supply Breaker trips OPENo Alternate Supply Breaker
automatically CLOSES
Which ONE of the choices below completes the following
statements?
The associated Diesel Generator is expected to
__________
Three (3) minutes later, PSW flow to the Turbine Building is
expected to
__________
A. remain in standby;have isolated
B. remain in standby;remain in service
C. have automatically started;have isolated
D. have automatically started;remain in service
37
-
HLT-07 RO NRC EXAM
38. 295004G2.4.11 001
Unit 2 was operating at 100% power.
o A loss of 2R25-S002. 125 VDC Cabinet 2B, occurs
o Subsequently, a malfunction occurs causing 2B31-FO31B, Recirc
2B Discharge Valve,to inadvertently travel full CLOSED
With the above conditions, which ONE of the choices below
completes the followingstatements?
As 2B31-FO31B CLOSES, the 2B ASD
_________
A. will perform a ‘Ramp Shutdown” to zero rpm and then the 4160V
Input Breaker must bemanually OPENED from the Control Room
B. will perform a “Ramp Shutdown” to zero rpm and then the 4160V
Input Breaker will tripOPEN
C. 4160V Input Breaker will remain closed UNTIL it is manually
OPENED LOCALLY
D. 4160V Input Breaker will IMMEDIATELY trip OPEN
38
-
HLT-07 RO NRC EXAM
39. 295005AK3.06 001
Unit 2 was operating at 100% RTP when the following
occurred:
o Startup Aux. Transformer (SAT) 2D de-energizedo Reactor
scrammedo Main Generator tripped
Which ONE of the choices below describes the expected status of
the 4160 VAC Station ServiceBuses 2A and 2B and why? (Assume NO
operator actions have been taken).
4160V buses 2A and 2B are
A. de-energized to prevent overloading SAT 2C
B. de-energized to prevent paralleling out of synch power
supplies
C. energized from SAT 2C to keep the Main Condenser
available
D. energized from SAT 2C to keep forced Core flow available
39
-
HLT—07 RO NRC EXAM
40. 295006AA1.01 001
Unit 2 is in a refueling outage.
o Reactor Mode Switch position REFUELo SRM Shorting Links
REMOVED
A SRM detector failure results in the SRM 2A indication reading
5x105 CPS.
What is the expected status of the 2H11-P603 panel WHITE RPS
Scram Group A and B lights?
RPS Scram Group A WHITE lights are expected to be
RPS Scram Group B WHITE lights are expected to be
__________
A. EXTINGUISHED;EXTINGUISHED
B. EXTINGUISHED;ILLUMINATED
C. ILLUMINATED;EXTINGUISHED
D. ILLUMINATED;ILLUMINATED
40
-
HLT-07 RO NRC EXAM
41. 295009AA1.03 001
Unit 1 is operating at 60% RTP with the following
conditions:
o “lB” RFPT in service with ‘lA” RFPT on its turning gearo Both
Recirculation Pump speeds are 65%
o “lB” RFP trips due to the running Condensate Booster pumps
trippingo RWL lowered to -65” before the operator recovered RWL to
+35” with HPCI
Which ONE of the choices below describes the FINAL condition of
BOTH RecirculationPumps?
A. Running at #1 speed limiter
B. Running at #2 speed limiter
C. Running at #3 speed limiter
D. Tripped
41
-
42. 295010G2.4.18 001
HLT-07 RO NRC EXAM
The following conditions exist on Unit 2:
o Drywell temperature = 300°Fo Drywell pressure 5 psigo Reactor
= shutdown (all rods in)o RPV water level = 32” and steady
GRAPH 8
DR’{WELL SPRAY INITIArJON LIMIT
FMatfl
With the above plant conditions, which ONE of the choices below
completes the followingstatements?
If Drywell Sprays are initiated, Primary Containment could
___________
The Unit 2 Primary Containment Design Temperature
__________
been exceeded.
A. fail from exceeding the capacity of the Torus-to-Drywell
vacuum breakers;has
B. fail from exceeding the capacity of the Torus-to-Drywell
vacuum breakers;has NOT
C. be de-inerted from opening the Reactor Bldg. to Torus vacuum
breakers;has
D. be de-inerted from opening the Reactor Bldg. to Torus vacuum
breakers;has NOT
OUt)
WSSS raresseesaOOrssa . rsarrarea rsssea4flfl PSFSSSSSA
&c’E_ /Ssarsrs.“. S‘a
,SAFEj
°°rinn
DWTEMP
(°F)
0 10 20 30 40DRY WELL PRESSURE (psig)
42
-
HLT-07 RO NRC EXAM
43. 295013AK2.01 001
Unit 1 is operating at 90% power.
o A Safety Relief Valve (SRV) inadvertently opened causing
Suppression Pool watertemperature to increase
o Suppression Pool water temperature reaches 102°F before
operators are able to close theSRV
Which ONE of the choices below describes the required Residual
Heat Removal (RHR)Suppression Pool Cooling alignment?
A. Place ONLY one loop of RHR in Suppression Pool cooling, and
the RHR heat exchangerIS required to be isolated prior to starting
the RHR pump.
B. Place ONLY one loop of RHR in Suppression Pool cooling, and
the RHR heat exchangerIS NOT required to be isolated prior to
starting the RHR pump.
C. Place ALL available RHR loops in Suppression Pool cooling,
and the RHR heat exchangerIS required to be isolated prior to
starting the RHR pumps.
D. Place ALL available RHR loops in Suppression Pool cooling,
and the RHR heat exchangerIS NOT required to be isolated prior to
starting the RHR pumps.
43
-
HLT-07 RO NRC EXAM
44. 295016AA2.07 001
The control room has been abandoned and 31RS-OPS-OO1-2, Shutdown
From Outside ControlRoom, is being implemented.
The SS has ordered Torus Sprays to be placed in service.
Which ONE of the choices below completes the following
statements?
Torus pressure can be determined using
Torus Sprays can be initiated from the Remote Shutdown Panel,
2C82-POO1, ONLY in the
A. SPDSintheTSC;“B” Loop
B. SPDSintheTSC;“A” Loop
C. a permanently mounted gauge on the 87’ level of the Reactor
Building;“B” Loop
D. a permanently mounted gauge on the 87’ level of the Reactor
Building;“A” Loop
44
-
HLT-07 RO NRC EXAM
45. 295018AK3.06 001
Unit 2 is operating at 5% power when two (2) RBCCW pumps fail
and will NOT run.
The following exists:
o PSW/RBCCW Hx dP increaseso The SS directs the SO to LOWER
PSW/RBCCW Hx dP to 30 psid by throttling
2P41-F491, PSW Outlet Valve From RBCCW Hx
JAW 34SO-P42-O0l-2, Reactor Building Closed Cooling Water
System, which ONE of thefollowing completes these statements?
To LOWER the PSW/RBCCW Hx dP, the SO will throttle 2P41-F491 in
the
_________
direction.
The setpoint for 650-23 8, HX PSW/RBCCW DIFF PRESS LOW, is
__________
A. CLOSE;7 psid
B. CLOSE;20 psid
C. OPEN;7 psid
D. OPEN;20 psid
45
-
HLT-07 RO NRC EXAM
46. 295019AA2.02 001
Unit 2 is operating at 100% power with 2P52-F565, “Rx Bldg Inst
N2 To Non-mt Air El 185Isol Vlv’, tagged in the closed position
when the following occurs:
o Unit 2 experiences a loss of ALL Unit 2 Station Service Air
Compressorso Instrument and Service Air pressure drops to zero (0)
psig
Which ONE of the choices below completes BOTH statements for the
following ventilationdampers as their respective air pressure
decreases to zero (0) psig?
2T46-FOO1A, SBGT A Fltr Inlet From Rx Bldg, valve will
__________
2T41-F044A, Rx Bldg Inboard Isol Dmprs Inaccessible Areas
Exhaust Fans Disch, valvewill
_______
A. travel open;remain open
B. travel open;travel closed
C. remain closed;remain open
D. remain closed;travel closed
46
-
HLT-07 RO NRC EXAM
47. 295020AK1.05 001
Unit 2 is operating at 100% power.
o Nitrogen (N2) is being added to the Unit 2 Drywell (DW) from
the Unit 1 N2 Storage Tank
34SO-T48-O022, “Containment Atmosphere Control and Dilution
System” section 7.3.1,‘Alternate Primary Containment Nitrogen
Makeup From CAD loop A, Unit 1 or Unit 2 N2Storage Tank” is being
used to add the N2.
o 2T48-F1 13, “Nitrogen to DW isolation valve” is OPENo 2T48-F1
14, “Nitrogen to DW isolation valve” is OPENo DW venting using
Standby Gas Treatment is in progresso A fault in 2C71-P001, “RPS
Power Dist Panel” results in a loss of the’2A” Reactor
Protection System (RPS) buso It will take 8 hours to restore the
“2A” RPS bus
If the operator stationed at the 2H1 1-P657 panel does NOT take
any action, which ONE of thefollowing describes the operational
implications for the DW?
A. N2 addition to the DW will continue and a loss of DW cooling
will eventually occur due tohigh DW pressure.
B. N2 addition to the DW will continue and DW cooling will
remain in operation indefinitely.
C. N2 addition to the DW will automatically isolate and DW
cooling will remain in operationindefinitely.
D. N2 addition to the DW will automatically isolate and a
simultaneous loss of DW coolingwill occur.
47
-
HLT-07 RO NRC EXAM
48. 295021G2.2.40 001
Unit 2 is shutdown.
BOTH Loops of RHR are operating in Parallel Shutdown Cooling
(SDC) operation.
The following conditons exist:
o Rx pressure 34 psigo BOTH Rx Recirculation pumps Offo “2C” RHR
pump Danger Tagged out of serviceo “2D” RHR pump Danger Tagged out
of service
Subsequently, an equipment malfunction causes 2E1 1-FOO6B,
Shutdown Cooling Vlv, toCLOSE and CANNOT be reopened.
Which ONE of the choices below completes the following
statements?
JAW Tech Spec LCO 3.4.7, ‘Residual Heat Removal (RHR) Shutdown
Cooling System -Hot Shutdown”, the MINiMUM number of REQUIRED RHR
SDC Subsystems
With 2E1 l-FOO6B closed, the “2B” RHR pump will
__________
A. is met;trip
B. is met;continue to run
C. is NOT met;trip
D. is NOT met;continue to run
48
-
HLT-07 RO NRC EXAM
49. 295023AA1.04 001
A refueling accident occurs on Unit 2.
The following Area Radiation Monitors (ARM) red Trip Lights
illuminate at Control RoomARM Panel 2D21-P600:
o 2D21-K6O1A, Reactor head laydown areao 2D21-K6O1M, Spent Fuel
Pool & New Storage
Which ONE of the following predicts how the Main Control Room
Environmental Control(MCREC) system is affected and operation of
the ARMs?
With the above conditions, the MCREC system will
___________
After mitigating actions are completed AND the above ARMs are
indicating below theirTrip setpoints, the ARM red TRIP lights
___________
reset.
A. remain in the Normal Mode;must be manually
B. remain in the Normal Mode;will automatically
C. align to the Pressurization Mode;must be manually
D. align to the Pressurization Mode;will automatically
49
-
HLT-07 RO NRC EXAM
50. 295024EA2.06 001
A steam line break inside containment has occurred on Unit
2.
o Drywell pressure is 10.5 psig and slowly increasingo Torus
pressure is 10 psig and slowly increasingo Neither Drywell or Torus
sprays have been initiated
Which ONE of the following describes the effect of the steam
line break on Torus watertemperature and requires Primary
Containment sprays with these conditions?
The Torus water temperature will heat up
With the above conditions and at this time, Sprays are REQUIRED
to be placedin service.
A. uniformly throughout the Torus due to the design of the
downcomers;
BOTH Drywell and Torus
B. uniformly throughout the Torus due to the design of the
downcomers;
ONLY Torus
C. directly under the area of the DW leak due to the energy
being distributed directly to theTorus water in that area;
BOTH Drywell and Torus
D. directly under the area of the DW leak due to the energy
being distributed directly to theTorus water in that area;
ONLY Torus
50
-
HLT-07 RO NRC EXAM
51. 295025G2.1.27 001
Which ONE of the choices below completes the following
statements?
JAW TS 3.4.3. Safety/Relief Valves (SIRVs), the SRV Safety
function requires aMINIMUM of
__________
SRVs to be operable.
if reactor pressure reaches 1200 psig, the Reactor Coolant
System DESIGN pressure
__________
have been exceeded.
A. 10;will
B. 10;will NOT
C.5;will
D.5;will NOT
51
-
HLT-07 RO NRC EXAM
52. 295026EK3.04 001
An ATWS is in progress on Unit 2 with 31E0-EOP-01 1-2, RCA RPV
Control (ATWS),flowchart in progress.
Which ONE of the choices below completes the following
statements?
JAW EOP definitions the reason SBLC is injected before exceeding
the B11T Curve(Graph 5) is to ensure that Hot Shutdown Boron Weight
is injected before exceeding the
At 10% RTP, the LOWEST listed Torus temperature at which the BuT
Curve (Graph 5)will be EXCEEDED is
________
Reference Provided
A. Primary Containment Pressure Limit;120°F
B. Primary Containment Pressure Limit;125°F;
C. Heat Capacity Temperature Limit;120°F
D. Heat Capacity Temperature Limit;125°F;
52
-
HLT-07 RO NRC EXAM
53. 295028EA1.03 001
Unit 2 was at 100% power when a Steam Line break occurred inside
the Drywell (DW).
The following conditions now exist:
o Drywell Pressure 8 psigo Bulk Average Drywell Temperature
265°F
Which ONE of the choices below completes the following
statement?
JAW 3 1EO-EOP- 100-2, Miscellaneous Emergency Overrides’,
the”2A” DW Chiller
A. is NOT allowed to be restarted, because this DW temperature
is above the allowed windingtemperature for restart of the DW
Cooling Fan Motors
B. is NOT allowed to be restarted, because at this DW
temperature the potential for a rupture inthe DW coolers exist
C. is allowed to be restarted. The operator must first place the
LOCA override switch to“BYPASS” and then reset the 86 Lockout relay
at the DW Chiller breaker
D. is allowed to be restarted. The operator must first reset the
86 Lockout relay at the DWChiller breaker and then place the LOCA
override switch to “BYPASS”
53
-
HLT-07 RO NRC EXAM
54. 295030EK1.02 001
Unit 2 is operating at 100% power when a Loss of Coolant
Accident occurs.
The High Pressure Coolant Injection (HPCI) system is being used
to control RPV water level.
o HPCI flow rate 4,000 gpmo RWL -60’ and increasing at 20” per
minuteo Torus level 135 incheso Torus temperature 190°Fo Torus
Pressure 4psig
With the above conditions, SELECT the HIGHEST listed flowrate
that maintains HPCIoperation in the ACCEPTABLE Region of the HPCI
NPSH limits?
Reference Provided
A. 3,750 gpm
B. 3,250 gpm
C. 2,750 gpm
D. 2,250 gpm
54
-
HLT-07 RO NRC EXAM
55. 295031EA1.02 001
Unit 2 was operating at 100% power, when an event occurred
resulting in the following:
o Reactor water level: -45” (lowest level reached) and
increasing 45 inches/minuteo Reactor pressure: 900 psig and slowly
decreasingo Drywell pressure: 0.8 psig and steadyo Both CRD pumps
tripped and can NOT be started
Which ONE of the choices below completes the following
statement?
Based on these conditions, with NO additional operator actions,
one (1) minute laterONLY
__________
will have indication of flow to the reactor vessel.
A. HPCI and RCIC
B. the Reactor Feedpumps
C. HPCI, RCIC and the Reactor Feedpumps
D. RCIC and the Reactor Feedpumps
55
-
HLT-07 RO NRC EXAM
56. 295032EA1.05 001
Following a transient on Unit 2, current plant conditions
are:
o Reactor water level is -20 inches, rising 5 inches/minuteo
Reactor pressure is 750 psig, slowly lowering
Subsequently the following conditions occur:
o RCIC Room Area Cooler Temperature is 160°Fo HPCI Room Area
Cooler Temperature is 175°Fo RCIC is injecting at 400 gpmo HPCI is
injecting at 600 gpm
Which ONE of the choices below completes the following
statements?
With the above conditions,
__________
REQUIRED to be MANUALLY isolated.
A. ONLY the HPCI System is
B. ONLY the RCIC System is
C. BOTH HPCI and RCIC Systems are
D. NEITHER HPCI nor RCIC Systems are
56
-
HLT-07 RO NRC EXAM
57. 295035EA2.02 001
Unit 2 is operating at 100% power with the following:
o 2T41C001A, “Rx. Bldg Supply Fan,” in service with 5,300 cfm
flowo 2T41-COO7A, “Rx Bldg Vent Exhaust Fan,” in service with 6,500
cfm flowo 2T41-COO7B, “Rx Bldg Vent Exhaust Fan,” is tagged out
Subsequently, 2T41-COO7A, “Rx Bldg Vent Exhaust Fan,” Trips.
With NO operator action, which ONE of the choices below
completes the following statements?
After 2T4l-COO7A trips, the Rx. Bldg SUPPLY Fan flow will
__________
After 2T41C007A trips, the Offsite release rate from the Rx.
Bldg Stack will
__________
A. remain at 5,300 cfm;decrease to zero (0) cpm because NO
Exhaust fans are discharging to the Rx. Bldg. Stack
B. remain at 5,300 cfm;decrease but remain greater than zero (0)
cpm since some Exhaust fans are still dischargingto the Rx. Bldg.
Stack
C. decrease to zero (0) cfm;decrease to zero (0) cpm because NO
Exhaust fans are discharging to the Rx. Bldg. Stack
D. decrease to zero (0) cfm;decrease but remain greater than
zero (0) cpm since some Exhaust fans are still dischargingto the
Rx. Bldg. Stack
57
-
HLT-07 RO NRC EXAM
58. 295037EK2.01 001
Unit 2 was at 84% RTP when it is discovered that the Alternate
Rod Insertion (ART) Systemwill NOT perform its intended
function.
Subsequently, an auto-scram signal was received.
The OATC inserted a manual scram and performed RC- 1.
The following conditions currently exist:
o Reactor power is 35% RTPo The 8 white RPS Scram Group lights
on 2H1 l-P603 are illuminatedo Full core display blue lights are
ALL extinguished
With the above conditions and JAW 31E0-EOP-103-2, EOP Control
Rod Insertion Methods,INDEPENDENTLY EVALUATE each of the following
control rod insertion methods todetermine if they will be an
effective method for control rod insertion?
Placing the RPS Test Trip Logic Switches to TRIP
_________
be effective.
Venting the Scram Air Header be effective.
A. will;will
B. will;will NOT
C. will NOT;will
D. will NOT;will NOT
58
-
HLT-07 RO NRC EXAM
59. 295038EK1.02 001
An event has ocurred at Plant Hatch with a potential radiation
release to the public.
Which ONE of the choices below completes the following
statements?
The NPO will determine Projected Offsite dose using
If an emergency is declared due to the high Offsite release
rate, the INITIAL emergencynotification to State and Local
Officials is REQUIRED within a MAXIMUM of
___________
from when the emergency is declared.
A. 73EP-EIP-015-O, Offsite Dose Assessment;15 minutes
B. 73EP-EIP-O 15-0, Offsite Dose Assessment;30 minutes
C. 73EP-EIP-018-0, Prompt Offsite Dose Assessment;15 minutes
D. 73EP-EIP-018-0, Prompt Offsite Dose Assessment;30 minutes
59
-
HLT-07 RO NRC EXAM
60. 300000K 1.02 001
Unit 2 is at 100% power with the following conditions:
o A Service Air Header break has occuredo The break is greater
than the capacity of the Service Air Compressors
Which ONE of the choices below completes the following
statements as Service Air pressuredecreases?
The isolation setpoint for 2P51-F017, Turbine Building Service
Air Isolation Valve,is
______________
If 2P51-F017 fails to isolate, CRD Flow Control Valves,
2C11-FOO2A & B
_________
losepneumatic supply.
A. 70 psig;will
B. 70 psig;will NOT
C. 50 psig;will
D. 50 psig;will NOT
60
-
HLT-07 RO NRC EXAM
61. 300000K6.04 001
Unit 2 is operating at 100% RTP with the 2P51-CO01C, Station
Service Air Compressor(SSAC), in service and 2P51-COO1B, SSAC, in
the Automatic Mode.
o 2P51-COOIC, SSAC, trips.
If NO operator action is taken, which ONE of the choices below
completes the followingstatements?
The setpoint at which 2P51-COO1B, SSAC, will Automatically Start
& Load is
________
If the 2P51-COO1B, SSAC fails to Start & Load, the Outboard
MSIVs (2B21-F028A-D),are expected to
__________
A. 100 psig;remain open
B. 100 psig;drift closed
C. 107 psig;remain open
D. 107 psig;drift closed
61
-
HLT-07 RO NRC EXAM
62. 400000K2.02 001
Unit 1 is at 100% power when the following annunciators
alarm:
o 600V BUS 1D BREAKER TRIPPED, 652-318o 600V BUS 1D
UNDERVOLTAGE, 652-323
Which ONE of the following lists two components that have lost
power?
A. RBCCW Pump A;RBCCW Drywell Outlet Isolation Valve,
1P42-F052
B. RBCCWPumpA;RWCU Inboard Suction Isolation Valve,
1G31-F001
C. RBCCWPumpB;RBCCW Drywell Outlet Isolation Valve, 1
P42-F052
D. RBCCWPumpB;RWCU Inboard Suction Isolation Valve, 1G3
1-FOOl
62
-
HLT-07 RO NRC EXAM
63. 500000EK3.07 001
Unit 1 has experienced an accident that results in these Primary
Containment parameters:
o Hydrogen concentration .... 8%o Oxygen concentration 7%o
Drywell (DW) pressure .... 14 psig and slowly increasingo Torus
level >300 inches
With the above conditions and JAW 31E0-PCG-001-1, “Primary
Containment Gas Control”chart, which ONE of the choices below
completes the following statements?
The operator is required to vent the
___________
the containment atmosphere.
Placing Torus Sprays in service
__________
allowed.
A. DW to reduce the flammability of;is
B. DW to reduce the flammability of;is NOT
C. Torus to reduce the flammability and scrub;is
D. Torus to reduce the flammability and scrub;is NOT
63
-
HLT-07 RO NRC EXAM
64. 600000AK1.02 001
A fire is reported on Unit 1, in the “lB’ Diesel Generator
Room.
Which ONE of the choices below is the fire suppression system
that is in this room?
A. Automatically actuated Carbon Dioxide System with a manual
backup
B. Automatically actuated Halon System with a manual backup
C. ONLY a manually actuated Carbon Dioxide System
D. ONLY a manually actuated Halon System
64
-
HLT-07 RO NRC EXAM
65. 700000AK2.07 001
BOTH units are operating at 100% power.
The Northern Control Center has notified the control room crews
that 230 KV Bus voltagecannot be maintained above the normal
minimum voltage.
Current 4160VAC Emergency Bus voltages are 3800 VAC.
Which ONE of the choices below completes the following
statements?
To RAISE reactive load (VARS) from the HMI Screen, the operator
will select
__________
lAW 34AB-S 11-001-0, Operation With Degraded System Voltage, if
after 30 minutes the4160VAC Emergency Bus voltages have not
changed, a TOTAL of__________ 4160VACEmergency Buses will be
transferred to their respective Diesel Generator.
A. EX2100 then REGULATOR ADJUST and depress RAISE;two (2)
B. EX2 100 then REGULATOR ADJUST and depress RAISE;four (4)
C. PSI-LOAD then LOAD SET and depress RAISE;two (2)
D. PSI-LOAD then LOAD SET and depress RAISE;four (4)
65
-
HLT-07 RO NRC EXAM
66. G2.1.2 001
Unit 2 experiences a Loss of ALL High pressure feed.
o LPCI and Core Spray (CS) automatically initiateo RWL is being
controlled by the OATC using LPCI and CS
RWL is recovered to its normal band and the OATC is ready to
depress the auto initiation signalreset pushbutton for RHR.
JAW 31G0-OPS-021-O, Manipulation Of Controls And Equipment,
which ONE of the choicesbelow completes the following
statement?
The
___________
does NOT have the AUTHORiTY to procedurally authorize resetting
theLPCI initiation signal under these conditions.
NOTE: Operator At The Controls = OATC; Balance Of Plant =
BOP
A. Shift Manager
B. OATConUnit2
C. BOP NPO on Unit 2
D. Extra NPO on Unit 2
66
-
HLT-07 RO NRC EXAM
67. G2.1.21 001
Southern Nuclear Operating Company
‘SOUTHERN Management Conduct of Operations Version 8.0
Nuclear I
I NMP-OS-007COMPANY Procedure Page 1 of 51Peer Team
ChampionlProcedure Owner: David R,Vineyard! Fleet Operations
Manager! Corporate
(Print: Name / Title I Site)
Original Signed by David Vineyard(Peer Team Champion/Procedure
Owner’s Approval Signature)
/ 12/08/2011(Approval Date)
Effective Dates:
CATEGORY SECTIONSContinuous: NONEReference: NONEInformation:
ALL
Based on the above cover sheet, which ONE of the choices below
completes the followingstatements?
JAW NMP-AP-001, Development and Control of Southern Nuclear
Procedures, on12/10/2011 this version of NMP-OS-007
_________
the CORRECT version to be used byOperations.
For the indicated PROCEDURE LEVEL OF USE, placekeeping is
__________
A. was;required
B. was;allowed, but NOT required
C. was NOT;required
D. was NOT;allowed, but NOT required
Approved By:
NACorporate
12/14/2011FNP
12/14/2011HNP
PROCEDURE LEVEL OF USE CLASSIFICATION PER NMP-AP..003
12/14/2011VEOP
67
-
HLT-07 RO NRC EXAM
68. G2.1.6 001
Which ONE of the following identifies the required communication
protocol during transientsJAW DI-OPS-59-896, Operations Management
Expectations, Attachment 5, Strategies ForSuccessful Transient
Mitigation?
An annunciator check
___________
required prior to the SS giving a crew brief.
If during a Crew Brief, alarms 603-205 & 603-206, Reactor
Vessel Level 2 Div I & Div IITrip, are received, the NPO
__________
expected to call a Time Out.
A. is;is
B. is;is NOT
C. is NOT;is
D. is NOT;is NOT
68
-
HLT-07 RO NRC EXAM
69. G2.2.23 001
Which ONE of the choices below identifies a Unit 1 Tech Spec LCO
condition that will requireentry into a Required Action Statement
(RAS)? (NOT A TRACKING RAS)
A. Torus water level is 149.5 inches in Mode 1.
B. RCIC is mop in Mode 3 with reactor steam dome pressure at 100
psig.
C. Reactor steam dome pressure is 1052 psig in Mode 1.
D. Drywell pressure is 1.80 psig in Mode 2.
69
-
HLT-07 RO NRC EXAM
70. G2.2.37 001
An event has occurred on Unit 2 requiring entry into 31 EO-EOP-
113-2, Terminating AndPreventing Injection Into The RPV.
JAW step 3.1.1.1, HPCI is OFF with 2E41-C002-3, HPCI Aux Oil
pump, in thePULL-TO-LOCK position.
Which ONE of the choices below completes the following statement
concerning HPCIoperability and Turbine Control Valve position?
lAW Tech Spec 3.5.1, HPCI is considered
__________
A. operable and the Turbine Control Valve will be fully
closed
B. operable and the Turbine Control Valve will be fully open
C. inoperable and the Turbine Control Valve will be fully
closed
D. inoperable and the Turbine Control Valve will be fully
open
70
-
HLT-07 RO NRC EXAM
71. G2.2.44 001
Unit 1 RHR Loop B has been placed in the Shutdown Cooling (SDC)
Mode of operation withthe following pump alignment:
RHR Pump lB Running in SDC ModeRHRSW Pump lB .... Running
The following alarms/conditions are received:
(601-3 14) RHR SYSTEM I ACTIVATED(60 1-234) RHR SYSTEM IT
ACTIVATEDReactor Water level is -120 inches
lAW 34S0-E1 1-010-1, Residual Heat Removal System, which ONE of
the choices belowcompletes the following statements concerning the
status of RHR Loop B Suction Valves?
With the above conditions, 1E1 1-FOO6B, Shutdown Cooling
Vlv,
__________
After 1E11-FOO6B is closed, the operator will
___________
A. must be manually CLOSED;verify 1E1 1-FOO4B, Torus Suction
Vlv, has automatically opened
B. must be manually CLOSED;manually open 1E1 l-FOO4B, Torus
Suction Vlv
C. will automatically CLOSE;verify 1E1 1-FOO4B, Torus Suction
Vlv, has automatically opened
D. will automatically CLOSE;manually open 1E1 l-FOO4B, Torus
Suction Vlv
71
-
HLT-07 RO NRC EXAM
72. G2.3.13 001
An INiTIAL Drywell (DW) entry is required on Unit 1.
With Unit 1 at 8% RTP, which ONE of the choices below completes
the following statementsJAW 31G0-OPS-005-O, Primary Containment
Entry?
The MAXIMUM reactor power allowed for this type of DW entry
(INITIAL) is
________
A Two (2) man Backup Team
___________
required to be in place for this entry.
A. lO%RTP;is
B. lO%RTP;is NOT
C. 15%RTP;is
D. 15%RTP;is NOT
72
-
HLT-07 RO NRC EXAM
73. G2.3.14 001
Unit 1 was at 35% power when the Hydrogen Injection System was
placed in service inAUTOMATIC - EXTERNAL mode JAW 34S0-P73-001-1,
“Hydrogen and Oxygen injectionand Control for HWC” section 7.1.2,
Placing 1P73-R025, Hydrogen Controller, inEXTERNAL.’
o Power is raised from 35% power to 100% powero At 100% power
hydrogen flow rate indicates 40 SCFM
Which ONE of the following answers both of these statements?
lAW 34S0-P73-001-l, “Hydrogen and Oxygen injection and Control
for HWC”, hydrogeninjection flow rate is
___________
the normal 100% power flow rate.
Main Steam Line radiation levels in the Steam Chase will
stabilize
___________
the expectednormal full power background radiation levels
estabilished JAW 34GO-OPS-001-1, PlantStartup.
A. above;at
B. above;above
C. below;at
D. below;below
73
-
HLT-07 RO NRC EXAM
74. G2.4.26 001
Which ONE of the choices below completes the following
statements concerning a fire in theService Building Document
Storage Room?
The Service Building Document Storage Room is equipped with
a
__________
fire suppression system.
JAW 3OAC-OPS-003-O, Plant Operations, a MINIMUM of Fire
BrigadeMembers must be onsite to respond to this fire.
A. Halon;five (5)
B. Halon;three (3)
C. CO2;five (5)
D. CO2;
three (3)
74
-
HLT-07 RO NRC EXAM
75. G2.4.32 001
Unit 2 was operating at 100% RTP when a loss of electrical power
results in a loss of asignificant number of Main Control Room
annuciators and a reactor scram.
An ALERT Emergency classification is declared.
Which ONE of the choices below completes the following
statement?
The LATEST time from the ALERT declaration that the INITIAL
Plant Page Announcementcan be made and still meet the requirements
of NMP-EP-111-002, Emergency NotificationNetwork Communicator
Instructions - Hatch, is
_________
Without additional direction from the Emergency Director, the
operator is REQUIRED tomake
_________
A. 15 minutes;the INITIAL Plant Page Announcement, followed by a
repeat Plant Page Announcementapproximately 30 minutes later
B. 15 minutes;ONLY the Initial Plant Page Announcement
C. 30 minutes;the INITIAL Plant Page Announcement, followed by a
repeat Plant Page Announcementapproximately 30 minutes later
D. 30 minutes;ONLY the Initial Plant Page Announcement
End of test 75
-
NRC RO REFERENCES
RO EXAM
1. Unit 2 EOP Graph 5, BuT Curve
2. Unit 2 EOP Graph 17A, HPCI Pump NPSH Limit, (Torus Water
Level At or Above 146”)
3. Unit 2 EOP Graph 17B, HPCI Pump NPSH Limit, (Torus Water
Level Below 146”)
-
BO
RO
NIN
JEC
TIO
NIN
ITIA
TIO
NT
EM
PE
RA
TU
RE
UN
IT2
170
160
TO
RU
S150
WA
TE
RT
EM
P140
(°F)
130
120
110
100
f%
.://
Z/4
,/
//‘;‘/)
///y4
/\f/
//
/•/.
‘/.7
/7
//
t//
7/7
/
-
240-
230-
230-
Torus
220-T
emp
(°F)
210-
200-
190-
HP
CI
PU
MP
NP
SH
LIM
IT(T
orusW
aterL
evelAt
orA
bove146”)
NO
TE
:M
ayuse
SPDS
Em
ergencyD
isplaysin
placeofthis
Graph.
*S
uppressionC
hamber
Pressure.*
*Safe
operatingregion
isbelow
theapplicable
pressureline.
UN
IT2
•rj4 rj4
_
At
or
Ab
ov
e10_psig
*
____
____
____
Belo
w10
psig
*
Belo
w5
psig
*
SA
FE
180-
170-I
0500
10001500
20002500
30003500
40004500
5000
HP
CI
FL
OW
(gpm)
-
240—
230-
220-T
orusT
emp
210-(°F)
200-
190-
180-
170-
HP
CI
PU
MP
NP
SH
LIM
IT(T
orusW
aterL
evelB
elow146”)
5u01000
15002000
25’OO
UN
IT2
30003500
40004500
5000
HP
CI
FL
OW
(gpm)
NO
TE
:M
ayuse
SPDS
Em
ergencyD
isplaysin
placeofthis
Graph.
*S
uppressionC
hamber
Pressure.*
*Safe
operatingregion
isbelow
theapplicable
pressureline.
At
or
Ab
ov
e10
psig
’
UN
SA
FE
•VA
.B
elow
10psig
*
___
Belo
w5
psig
*
4
16&
**SA
FE
U
-
HLT-07 RO NRC EXAMAnswers
# ID 01 201001K1.11 I D2 202001A1.02 I D3 202002K3.03 I C4
203000G2.4.34 I C5 204000K4.O1 1 C6 205000K5.02 1 A7 206000K5.06 I
C8 209001K1.12 I D9 209001K5.O1 1 C10 211000K4.021 Dii 212000A2.08
I B12 212000K3.03 1 D13 215002K6.04 I B14 215003A1.06 I B15
215004K6.02 I D16 215005A1.O1 I D17 215005A4.03 I D18 216000A4.01 1
A19 217000K2.04 I C20 218000KI.04 I B21 223001A3.04 1 C22
223002K3.10 1 A23 233000K2.02 I B24 234000K5.02 I D25 239002A3.02 1
C26 241000A2.23 I D27 259002A4.07 I D28 261000A1.01 1 C29
261000K3.02 I D30 262001G2.4.47 I A31 262002A3.01 I B32 263000A2.02
I A33 264000K4.06 I A34 268000A4.01 1 B35 286000G2.4.9 I A36
295001AK2.01 1 C37 295003AK1.03 1 D38 295004G2A.1l I C39
295005AK3.06 1 A40 295006AA1.01 I A41 295009AA1.03 1 D42
295010G24.18 I D43 295013AK2.01 I D44 295016AA2.07 1 A45
295018AK3.06 1 C46 295019AA2.02 1 B47 295020AK1.05 1 A
-
AnswersID 0
48 295021G2.2.40 I C49 295023AA104 I C50 295024EA2.06 1 B51
295025G2.1.27 1 B52 295026EK3.04 1 D53 295028EA1.03 I B54
295030EK1.02 I C55 295031EA1.02 1 C56 295032EA1.05 I A57
295035EA2.02 1 D58 295037EK2.01 I A59 295038EK1.02 1 C60
300000K1.02 I B61 300000K6.04 I A62 400000K2.02 I C63 500000EK3.07
1 B64 600000AK1.02 1 A65 700000AK2.07 I A66 G2.1.21 B67 G2.1.21 I
D68 G2.1.6 1 A69 G2.2.23 1 D70 G2.2.37 1 C71 G2.2.44 I B72 G2.3.13
I A73 G2.3.14 I B74 G2.4.26 1 A75 G2.4.32 I ASECTION 1 (75 items)
75.00