Non-invasive Microwave Breast Cancer Detection - A Comparative Study

Arezoo Modiri, Kamran KiasalehUniversity of Texas at Dallas

Page 2: 12-CRS-0106 REVISED 8 FEB 2013 Non-invasive Microwave Breast Cancer Detection - A Comparative Study Arezoo Modiri, Kamran Kiasaleh University of Texas.

http://www.cancer.org/acs/groups/content/@epidemiologysurveilance/documents/document/acspc-031941.pdf

Why New modality for Breast Cancer Detection in Needed?

Page 3: 12-CRS-0106 REVISED 8 FEB 2013 Non-invasive Microwave Breast Cancer Detection - A Comparative Study Arezoo Modiri, Kamran Kiasaleh University of Texas.

Why Microwave-Based Diagnosis?

Frequent checkups need in-vivo, inexpensive, non-invasive, and convenient methods with

acceptable accuracy.

X-Ray:

- Ionizing,

- High false negative detection rate

(20%)

- In many cases, Painful

MRI:

- Expensive

- Not tolerable for some

Women (e.g. implant cases)

Ultrasound:

- Operator-dependent

- High false positive detection rate

(The false-positive rate is three times of that of X-ray => unnecessary biopsy.)

http://www.cancer.gov/cancertopics/factsheet/detection/mammograms

Page 4: 12-CRS-0106 REVISED 8 FEB 2013 Non-invasive Microwave Breast Cancer Detection - A Comparative Study Arezoo Modiri, Kamran Kiasaleh University of Texas.

Why Microwave-Based Diagnosis?

Microwave radiation is not ionizing and the heating effect is not harmful at low power levels (less than OSHA standard of 10 mW/sq. cm.)

Penetration depth is acceptable for breast monitoring

Microwave technology is mature; thus, manufacturing microwave devices is relatively easy & cost-effective

The standard component size at microwave band has the potential of creating a handheld, portable device

Page 5: 12-CRS-0106 REVISED 8 FEB 2013 Non-invasive Microwave Breast Cancer Detection - A Comparative Study Arezoo Modiri, Kamran Kiasaleh University of Texas.

Are Any Other Research Groups Working On This Subject?

Dr. Paul Meaney – DartMouthDr. Susan Hagness – University of WisconsinDr. Elise Fear – University of CalgaryDr. Magda El-shenawee – University of ArkansasDr. Sima Noghanian – University of North DakotaDr. Natalia Nikolova – McMaster UniversityDr. John Stang – Duke University

Page 6: 12-CRS-0106 REVISED 8 FEB 2013 Non-invasive Microwave Breast Cancer Detection - A Comparative Study Arezoo Modiri, Kamran Kiasaleh University of Texas.

Other Studies Target Clinical Applications

Page 7: 12-CRS-0106 REVISED 8 FEB 2013 Non-invasive Microwave Breast Cancer Detection - A Comparative Study Arezoo Modiri, Kamran Kiasaleh University of Texas.

This Study’s Ultimate Goal

Portable, Self-Examine Tool which compensates for the defects of mammography by making check ups easier and more affordable for women and sending them to X-ray or MRI monitoring only when a signature is detected.

Page 8: 12-CRS-0106 REVISED 8 FEB 2013 Non-invasive Microwave Breast Cancer Detection - A Comparative Study Arezoo Modiri, Kamran Kiasaleh University of Texas.

3D Radiator Design

The 3D radiator design was done in Ansoft HFSS

The digital phantom created by Ansoft was used

In order to have a full coverage of the tissue, hemisphere shape was chosen with 16 curled bent dipole antennas

Design frequency was chosen to be 1.2GHz since this was the longest antenna we could fit inside our structure

Page 9: 12-CRS-0106 REVISED 8 FEB 2013 Non-invasive Microwave Breast Cancer Detection - A Comparative Study Arezoo Modiri, Kamran Kiasaleh University of Texas.

Resonance Performance of The Antennas

1.2 GHZ

Page 10: 12-CRS-0106 REVISED 8 FEB 2013 Non-invasive Microwave Breast Cancer Detection - A Comparative Study Arezoo Modiri, Kamran Kiasaleh University of Texas.

The Two Versions of The Radiating Structure

One without conductive cover

One with a conductive cover added for Electromagnetic Shielding– Cause no interference

– Accept no interference

– Only the outer surface of the structure is covered by a conductive layer

Page 11: 12-CRS-0106 REVISED 8 FEB 2013 Non-invasive Microwave Breast Cancer Detection - A Comparative Study Arezoo Modiri, Kamran Kiasaleh University of Texas.

Different Tumor Cases Are Considered

Different tumor shapes

Different tumor sizes

Different tumor locations

Page 12: 12-CRS-0106 REVISED 8 FEB 2013 Non-invasive Microwave Breast Cancer Detection - A Comparative Study Arezoo Modiri, Kamran Kiasaleh University of Texas.

Electric Field Changes Are Studied

Both magnitude and phase contrasts are considered.

Cancerous model is exactly same as the normal one except for having one of the tumors inside it

Page 13: 12-CRS-0106 REVISED 8 FEB 2013 Non-invasive Microwave Breast Cancer Detection - A Comparative Study Arezoo Modiri, Kamran Kiasaleh University of Texas.

How Signatures Are Analyzed

The signatures above a certain threshold are

added up.

Page 14: 12-CRS-0106 REVISED 8 FEB 2013 Non-invasive Microwave Breast Cancer Detection - A Comparative Study Arezoo Modiri, Kamran Kiasaleh University of Texas.

Simulation Results for Two Tumor Cases

Page 15: 12-CRS-0106 REVISED 8 FEB 2013 Non-invasive Microwave Breast Cancer Detection - A Comparative Study Arezoo Modiri, Kamran Kiasaleh University of Texas.

Specific Absorption Rate on Cut PlaneOSHA Compliance

SAR is 3.5W/Kg at the hottest spot.

The sphere is filled with fat.

1000 centimeter cube of fat is almost equal to 0.9Kg.

At the hottest spot, the power distribution is equal to (3mW/cubic cm) which is well

below the OSHA standard of (10 mW/square cm)