1104D-44 TG2, 1104D-44 TG3 TPD1818 - Diperk Power · PDF fileBarometric pressure ... the test conditions, ... For full details, contact Perkins Technical Service Department. Emissions
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Overall dimensionsLength, front of radiator to rear of air cleaner .. ... ... ... ... 1239 mmWidth ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ..615 mmHeight, including radiator support brackets . ... ... ... ... ... ..951 mm
Moments of inertia (mk²)Engine rotational inertia (excluding, pulley, flywheel) ..0.1402 kgm²Crank pulley inertia (dependant on option code) . ... .Refer to ESMFlywheel inertia (dependant on option code)... ... ... ... ...1.14 kgm²
Centre of gravity - Fan to flywheelForward from rear of block - wet.. ... ... ... ... ... ... ... ... ...227.2 mmAbove crankshaft centre line - wet... ... ... ... ... ... ... ... ...160.4 mmOffset to RHS of crankshaft centre line - wet... ... ... ... ... ...8.1 mm
PerformanceNote: All data based on operation to ISO 3046-1:2002 standard reference conditions.
Test conditionsAir temperature . ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... 25 °CBarometric pressure.. ... ... ... ... ... ... ... ... ... ... ... ... ... ... 100 kPaRelative humidity... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... .. 30%Air inlet restriction at maximum power (nominal) .. ... ... ... ... -3 kPaExhaust back pressure at maximum power (nominal) .. ... .. 12 kPaFuel temperature (inlet pump)... ... ... ... ... ... ... ... ... ... ... ... 40 °C
Sound levelAverage sound pressure level for ElectropaK... ... ... . 104.5 dB(A)If the engine is to operate in ambient conditions other than those of the test conditions, suitable adjustments must be made for these changes. For full details, contact Perkins Technical Service Department.
Emissions statement:Certified against the requirements of EU 2011 97/68/EC Stage IIIa.
of 10
l information in this document is substantially correct at time printing and may be altered subsequently.
Recommended coolant Perkins extended life coolant (ELC) coolants to 1E196650% anti freeze / 50% water. For complete details of recommended coolant specifications, refer to the Operation and Maintenance Manual for this engine model.
Maximum additional restriction (Duct allowance) to cooling airflow and resultant minimum airflow.Pusher
Am
bien
t cle
aran
ce
Duc
t allo
wan
ce
Coo
ling
fan
airf
low
Rad
iato
r cor
ere
sist
ance
rpm °C Pa m³/min Pa
150046 200 154
53 120 182
180046 200 184
53 120 218
Note: Above table example only.
Electrical systemAlternator Unit N0101
Alternator voltage Volts 12
Alternator output Amps 65
Starter Unit E0311
Starter motor voltage Volts 12
Starter motor power kW 3.2
Number of teeth on flywheel (D0004) 126
Number of teeth on starter pinion 10
Minimum cranking speed rpm 130
Starter solenoid - Maximum pull-in current @ -20°C Amps 62
Starter solenoid - Maximum hold-in current @ -20°C Amps 14
Notes:Glow plugs needed below -10°CFor cable sizes see Applications and Installation manual.
The table above shows the recommended battery sizes against starter model, temperature and oil viscosity and is based on the test results from starting a ‘bare’ engine with batteries at a 75% state of charge and with a cable resistance of 0.0017 Ohms.
Fuel specificationPerkins recommend the use of the following fuel specifications:
DIN E 590 DERV Grade A, B, C, E, F, Class 0, 1, 2, 3 and 4BS2869 Class A2 Off-highway Gas Oil Red DieselASTM D975, Class 1D and Class 2DJIS K2204 Grades 1, 2, 3 and Special Grade 3.
Note: For further information on fuel specifications and restrictions, refer to the OMM Fuels section for this engine model
Fuel consumption (SFC)Fuel Consumption Units 50Hz 60Hz
110% of prime litres/hour 18.2 21.0
100% of prime litres/hour 16.5 18.8
75% of prime litres/hour 12.4 14.3
50% of prime litres/hour 8.3 9.8
25% of prime litres/hour 4.8 5.8
SFC gross @ 110% of prime g/kWhr 235 247
SFC gross @ 100% of prime g/kWhr 235 243
SFC gross @ 75% of prime g/kWhr 232 246
SFC gross @ 50% of prime g/kWhr 230 253
SFC gross @ 25% of prime g/kWhr 265 300
Note: All figures based on gross mechanical output, for fuel consumption based on electrical output of the generating set contact your OEM.