Top Banner
1: Developing near real- time DEP hardware Nahrizul Adib Kadri [email protected]
17

100428 ug2

Dec 06, 2014

Download

Education

Nahrizul Kadri

A short introduction on DEP and the work that I'm doing at Biomedical Engineering Centre, University of Surrey
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 100428 ug2

1:18

Developing near real-time DEP hardware

Nahrizul Adib [email protected]

Page 2: 100428 ug2

2:18

What’s DEP?

• Electrophoresis– Charged particles moving in uniform field

D ie lec tric pa rtic le

Page 3: 100428 ug2

3:18

What’s DEP?

• Dielectrophoresis– Dielectric particles moving in non-uniform field

Dielectric particle

Die lectric particle

Positive DEP Negative DEP

Page 4: 100428 ug2

4:18

What’s DEP?

• Theory bit– (the only time an equation appears in this

presentation… promise!)

232F E)K(Rer m

**

**

2)(

mp

mpK

j

*

Page 5: 100428 ug2

5:18

What’s DEP used for?

• Cell movement can be manipulated by frequency changes, so DEP is good for cell collection and sorting

Morgan et al. Biophysical Journal 77 (1999) 516-525

Page 6: 100428 ug2

6:18

What’s DEP used for?

• Compare cell viability

G.H. Markx, C.L. Davey / Enzyme and Microbial Technology 25 (1999) 161–171

Page 7: 100428 ug2

7:18

What’s DEP used for?

• Compare effects of chemicals on cells

F.H. Labeed et al. / Biochimica et Biophysica Acta 1760 (2006) 922–929

Page 8: 100428 ug2

8:18

What’s DEP used for?

• Predict cell properties

232F E)K(Rer m

Page 9: 100428 ug2

9:18

What’s DEP used for?

• Everything’s fine and dandy BUT DEP is not available commercially, nor used widely– Despite being described back in 1950s

• …but why?– Small assays only

• Restricted to research use

– Time consuming• One spectrum takes 40-60 minutes

Page 10: 100428 ug2

10:18

What’s DEP used for?

• The answer(?): Multiple experiments at the same time!– Different

frequencies, or– Same frequencies

10kHz 2MHz

300um

Page 11: 100428 ug2

11:18

http://www.youtube.com/watch?v=lLZbr3vP-Zs

Page 12: 100428 ug2

12:18

DEP: The setup

• What’s needed:

Imaging/recording device

Microscope

Electrode

Cells

Signal generator

Page 13: 100428 ug2

13:18

DEP: The (new) setup

• What’s (really) needed:

Imaging/recording device

Microscope

Electrode

Cells

Multiple output signal generator

Page 14: 100428 ug2

14:18

Real-time DEP

Page 15: 100428 ug2

15:18

Real-time DEP

103

104

105

106

107

108

-1

-0.8

-0.6

-0.4

-0.2

0

0.2

0.4

0.6

0.8

1

Frequency (Hz)

Nor

mal

ised

ligh

t in

tens

ity

DEP plots for Jurkat cells treated with valinomycin 100402 (10 mS/m)

Control

Valinomycin

Page 16: 100428 ug2

16:18

Real-time DEP

105

106

05

1015

20

25-1

0

1

2

3

4

5

Frequency (Hz)

DEP spectrum for Jurkat cells treated with valinomycin 091216

Time (min)

Mod

al s

hift

Page 17: 100428 ug2

17:18

Real-time DEP

• That’s it! (for now, hopefully)

• Any questions: – [email protected]– facebook.com/nahrizuladib