01 02 03 Sr. NO. 01 DETAIL OF RESIDENTIAL PLOTS :- TOTAL AREA OF RESIDENTIAL POCKET:- = 9.96 ACS. 01 03 02 CATEGORY NO. OF PLOTS AREA IN ACS. 44 2.27 75 4.86 ACS. 10 MARLA PLOTS TOTAL 31 2.59 16 MARLA PLOTS 123.44 ACS. 65.88 % TOTAL SALEABLE SALEABLE AREA 01 AREA UNDER PLOT IND.+RESI 120.40 02 03 AREA UNDER COMMERCIAL ( 40 % OF 1.54 AREA ) CATEGORY S.NO. AREA IN ACS. S.NO. AREA UNDER ELECT. SUB. STN. AREA UNDER PUBLIC BUILDINGS ( 75 % OF 0.80 AREA ) 0.61 1.83 0.60 04 NOTE:- THIS DRAWING IS COMPUTERIZED REPRODUCTION OF ORIGINAL DRG. NO. P.S.I.E.C./E.W/D.T.P/ 01/11, DATED. 24.07.91 AND PREPARED ON 31 / 01 / 2017. TOTAL AREA OF THE SCHEME:- = 187.37 ACS. DIVISIONAL TOWN PLANNER DRAWN BY:- SCALE :- 220'-0" TO AN INCH CHIEF ENGINEER Sd/- Sd/- 220 110 0 220 440 N DRG. NO.:- P.S.I.E.C. / E.W / D.T.P / 01/11 DATED :- 24-07-91 Sd/- LAYOUT PLAN FOR INDUSTRIAL FOCAL POINT AT PATIALA ASSTT. TOWN PLANNER:- Sd/- ( S.D.SADHU ) ( JASWANT SINGH ) ( SATESH RANA ) ( SWARAN SINGH ) PLANNING OFFICER:- CHECKED BY:- Sd/- Sd/- DETAIL OF PLOTS:- 04 05 150'-0" X 300'-0" CATEGORY OF PLOT NO. OF PLOTS AREA IN ACS. 1.0 ACS. AND ABOVE PLOTS 10 TOTAL 664 115.54 ACS. 1 2 ACS. AND ABOVE PLOTS 1 4 ACS. PLOTS 500.0 SQ. YARDS PLOTS 250.0 SQ. YARDS PLOTS 90'-0" X 250'-0" 60'-0" X 150'-0" 45'-0" X 100'-0" 30'-0" X 75'-0" SIZE OF PLOTS 34 231 342 47 11.35 19.69 47.74 02.46 34.30 0.97 187.37 ACS. 100% TOTAL DETAIL OF AREAS:- AREA UNDER PLOT INDUSTRIAL 115.54 AREA UNDER COMMERCIAL AREA UNDER ELECT. SUB. STN. AREA UNDER WATER WORKS 61.66 S. NO. CATEGORY AREA IN ACS. % AGE 1.54 0.80 1.83 52.81 3.09 1.80 0.82 0.42 0.96 28.18 1.64 01 03 02 04 05 06 07 AREA UNDER PUBLIC BUILDINGS AREA UNDER ROAD/OPEN SPACE AREA UNDER DISPOSAL WORKS 9.96 5.31 08 AREA UNDER RESIDENTI. POCKET PREPARED BY :- J.D.M ( VINOD DHIMAN ) CHECKED BY :- J.D.M ( VIKAS GUPTA ) GENERAL MANAGER PLANNING ( SUKHDEV SINGH ) ( J.S RANDHWA ) ASSTT. TOWN PLANNER:- 1300'-0" 1547'-4" 900'-0" 80'-0" 540'-0" 450'-0" 60'-0" 320'-0" 360'-0" 141'-0" AS/SITE 3060'-0" 3500'-0" 1480'-0" 161'-0" 125'-0" 664'-11 1 2 " 152'-0" 3) AS PER ORDER OF M.D ON DATED. 14-9-06 ONE 3916.66 SQ. YARDS PLOT HAS BEEN CARVED OUT AND NUMBERED AS B-28A OUT OF PLOT NO A-10. 4) AS PER ORDER OF MANAGING DIRECTOR DATED 04.04.2007 PLOT NO. C-219 HAS BEEN SHIFTED DUE TO (HIGH TENSION LINE) ADJOINING PLOT NO. C-218 AND LAND UNDER PLOT NO. C-219 CONVERTED INTO OPEN SPACE. 5) AS PER ORDER OF STANDING ORDER DATED 17.12.2010 LOCATION OF PLOT NO. R-29 TO R-44 AND R-60 TO R-75 HAS BEEN CHANGED. 6) AS PER ORDER OF M.D PSIEC DATED 14.11.2011 PLOT NO. B-28A HAS BEEN KEPT RESERVED FOR PHULKARI MRGA PROJECT. 7) AS PER THE ORDER OF BOARD OF DIRECTORS DATED 24.12.2015 ROAD ADJOINING PLOT NO. B-24 DE-RESERVED AND CARVED OUT 1642 SQ YARDS INDUSTRIAL PLOTS NUMBERED AS B-24A 8) AS PER DECISION TAKEN IN THE LAYOUT PLAN APPROVAL COMMITTEE DATED 05-10-2016. 1.54 ACS. COMMERCIAL POCKET HAS BEEN PLANNED ON THE ENTRY POINT OF INDUSTRIAL FOCAL POINT & COMMERCIAL POCKET ALREADY PLANNED HAS BEEN CONVERTED INTO GREEN BELT. C-113 C-65 C-66 C-67 C-68 C-69 C-70 C-71 C-72 C-73 C-74 C-75 C-76 C-78 C-79 C-80 C-81 C-82 C-83 C-84 C-85 C-86 C-87 C-88 C-89 C-90 C-91 C-92 C-93 C-94 C-95 C-96 C-97 C-98 C-99 C-100 C-101 C-102 C-103 C-104 C-105 C-106 C-107 C-108 C-109 C-110 C-111 C-64 C-63 C-52 C-51 C-1 C-2 C-13 C-14 C-50 C-49 C-15 C-16 C-34 C-33 C-31 C-32 GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG D-25 G G G G G G G G G G D-34 D-44 D-35 G G G G G G G G G G D-45 D-80 D-62 D-63 GG GG GG GG GG GG GG GG G G G G GG GG GG GG GG GG GG GG D-1 D-12 D-24 D-13 GG GG GG GG GG G G GG GG GG GG GG G G D-81 D-90 D-100 D-91 D-110 D-111 D-101 D-120 G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G D-134 D-135 D-121 D-148 D-133 D-136 D-122 D-147 D-89 D-92 A-2 GG GG GG GG GG GG A-3 A-4 A-5 A-6 B-2 B-3 B-4 B-5 B-6 B-7 B-8 WATER WORKS AREA = 1.80 ACS. B-1A C-233 C-232 B-1 A-1 G G G G G R-44 R-29 R-37 R-36 R-51 R51A R-52 R-59P R-45P R-50 C-122 C-115 G G G G G G G G G G G G G G G G G G G G G G G G G G G G GG GG GG GG GG GG GG G G G G G G G G G G G G G G G G GG GG GG GG GG GG GG GG GG G G GG GG GG GG GG GG GG GG GG G G GG GG GG GG GG GG GG G GG GG GG GG GG GG GG G GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG G GG GG GG GG GG GG GG G G G G G G G G G GG GG GG GG GG GG GG GG GG GG GG GG G GG G G G G GG G G G G GG G G G G G G G G GG G G GG G G GG G G G G G G G G GG G G G G G G G G GG G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G GG GG GG GG GG GG GG GG GG GG GG GG G G G G GG GG G G G G GG G G G G GG G G GG GG GG GG GG GG G GG G GG G GG G C-226 GG GG GG GG GG GG C-227 C-228 C-229 C-230 C-231 G D-149 B-9 B-10 B-11 B-12 B-13 B-14 B-15 B-16 B-17 B-18 B-19 A-7 A-8 A-9 B-20 B-21 B-22 B-23 B-24 B-24A B-25 B-26 B-27 B-28 B-28A A-10 AREA = 3916.66 S.Y P.M.P ELEC. SUB STATION AREA = 1.83 ACS. D-178 D-159 D-179 D-198 D-214 D-199 D-215 D-230 D-250 D-231 D-251 D-270 D-286 D-271 D-287 D-302 D-303 D-322 D-342 D-323 R-53 R-54 6'-0" 8'-0" 8'-0" 22'-0" 4'-0" 10'-0" 6'-0" 2'-0" 4'-0" 5'-0" 2'-0" 3'-0" 36'-0" 22'-0" 22'-0" TELEPHONE LINE DISTRIBUTION LINE 8' -0" BERM 8' -0" BERM SWD W/S SWD 80'-0" C/WAL C/WAL 3' 1'-6" 5'-0" 3' 2'-6" 17'-0" 10'-0" 10'-0" 5'-0" 3' 15'-0" 17'-0" 28'-0" 60'-0" W/S SWD SEWER BERM BERM TELEPHONE LINE DISTRIBUTION LINE CURB CHANNEL C/WAL C/WAL CURB CHANNEL BERM BERM TELEPHONE LINE DISTRIBUTION LINE 3' 1'-6" 3' 2'-6" 2'-0" 13'-0" 7'-6" 6'-6" 3' 3' 12'-0" 13'-0" 20'-0" 45'-0" C/WAL C/WAL C-156 C-157 C-147 C-166 C-167 C-190 C-178 C-179 C-177 C-180 C-168 C-189 C-191 C-192 C-200 C-220 C-224 C-225 C-201 C-206 C-207 C-211 C-215 C-217 C-216 C-218 C-219 C-212 C-213 C-214 C-123 C-132 C-133 C-134 C-124 C-146 C-137 TO C-135 C-145 C-138 1 2 3 14 15 16 19 18 17 30 31 32 33 36 35 34 45 46 47 B-32 B-33 AREA = 0.83 ACS. AREA = 0.83 ACS. 1 2 ACS. AND ABOVE 1 2 ACS. AND ABOVE B-29 B-30 B-31 DISPOSAL WORK AREA = 3.09 ACS. C-112 AREA = 1100 SQ.YDS. R-10P R-1P R-9 2 D-150 D-151 D-152 D-153 D-154 D- 155 R-11P R-12 R-18 R-19P R-28P R-27 R-21 R-20P R-60 R-67P R-66 R-61 R-68P R-69 R-75 R-74 200' 45' 200' 45' 200' 80' 300' 45' 300' 300' 60' 300' 45' 150' 45' 45' 200' 60' 300' 45' 375' 45' 300' 80' 250' 60' 150' 2940' 325' 45' 200' 45' 200' 60' 200' 60' 200' 60' 840' 150' 1080' 60' 45' 200' 45' 215' 45' 200' 80' 300' 45' 150' 60' 250' 80' 200' 45' 900' 630' 75' 810' 150' 150' 150' 150' 150' 90' 90' 90' 90' 90' 90' 90' 600' 45' 45' 45' 150' 150' 60' 45'-0"WIDE ROAD 45'-0"WIDE ROAD 45' 45'-0"WIDE ROAD 45' NOTE:- 1) SCHEME AREA WAS INCREASED FROM 186.80 ACRES TO 187.37 ACRES IN VIEW OF CORRIGENDUM ISSUED VIDE LAC / ASSTT./ 82 / PTA / 4091.D, DATED 28.07.1992. 2) LAYOUT PLAN HAS BEEN AMENDED AS PER PROCEEDING OF MEETING OF STANDING COMMITTEE DATED 12.01.2006 RE-PLANNED OF PLOT NO. D-152 TO D-158 AND C-111, B-34. 500 SQ. YDS 45'-0"X100'-0" D-2 D-23 D-26 D-43 500 SQ. YDS 45'-0" X 100'-0" 500 SQ. YDS 45'-0" X 100'-0" 500 SQ. YDS 45'-0"X100'-0" 16 M PLOTS 40'-0" X 90'-0" 30' X 75' 1 4 ACS. PLOTS 60'-0" X 150'-0" 900' 35' 1 4 ACS. PLOTS 60'-0" X 150'-0" 360' 120' 10 M PLOTS 30'-0" X 75'-0" ONE ACS. AND ABOVE PLOTS 1000 SQ.YDS 60' 30'-0"WIDE ROAD H.T. LINE 1 4 ACS. PLOTS 60'-0" X 150'-0" PUBLIC BUILDING 45'-0"WIDE ROAD PSIEC SCHEME BOUNDARY ( Y.P. SHARMA ) E E E AREA = AS /SITE PLOT NO. B-8A AREA =2000 SQ. YDS C-153 C-152 TO R-71 UN- ALLOTTED RESIDENTIAL PLOTS SHOWN THUS 400 SQ YDS UN- ALLOTTED RESIDENTIAL PLOTS SHOWN THUS 250 SQ YDS 30 31 32 33 34 35 38 39 40 41 42 43 46 47 48 49 55 56 57 58 3 4 5 6 7 8 13 14 15 16 17 22 23 24 25 26 62 63 64 65 70 72 73