Top Banner
10 Dec 2004, Mid-term Review in Mil Applied Cryodetectors Research Training Network funded by the European Commission's 5th Framework programme Improving Human Potential Carlo Pelliciari INAF-Osservatorio Astronomico G.S. Vaiana, Palermo, Italy
18

10 Dec 2004, Mid-term Review in Milano Applied Cryodetectors Research Training Network funded by the European Commission's 5th Framework programme Improving.

Jan 16, 2016

Download

Documents

Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 10 Dec 2004, Mid-term Review in Milano Applied Cryodetectors Research Training Network funded by the European Commission's 5th Framework programme Improving.

10 Dec 2004, Mid-term Review in Milano

Applied Cryodetectors

Research Training Network funded by the European Commission's 5th Framework programme

Improving Human Potential

Carlo Pelliciari

INAF-Osservatorio Astronomico G.S. Vaiana, Palermo, Italy

Page 2: 10 Dec 2004, Mid-term Review in Milano Applied Cryodetectors Research Training Network funded by the European Commission's 5th Framework programme Improving.

What I am going to show

• A brief C.V.

• Present position

• The XACT facility

• Fixed exit X-ray monochromator system

• RTN project: Microcalorimeter array development for

X-ray astronomy

• Conclusions

10 Dec 2004, Mid-term Review in Milano

Page 3: 10 Dec 2004, Mid-term Review in Milano Applied Cryodetectors Research Training Network funded by the European Commission's 5th Framework programme Improving.

Something about me

• 1996: Graduate on Physics @ University of Ferrara (Italy): “Fixed-exit monochromator for hard X-ray beams (8-130 keV) for astrophysics instrumentation tests”;

• 1997: 9 months fellowship @ DSRI (Denmark) : characterization of X-ray single-layer and multilayer mirrors;

• 1998 - 2001: Research Contracts @ University of Ferrara (Italy), Physics department: X ray optics development, realization of a X ray monochromator system, upgrading of the X-ray facility, JEM-X detector calibration (INTEGRAL project);

• 2002 - 2003: European fellowship (1y) + RTN Contract (1y) @ CEA/SAp(France): development and characterization of micro-calorimeter for X-ray astronomy.

10 Dec 2004, Mid-term Review in Milano

Page 4: 10 Dec 2004, Mid-term Review in Milano Applied Cryodetectors Research Training Network funded by the European Commission's 5th Framework programme Improving.

Present positionResearch Contract @ INAF-Osservatorio Astronomico G.S.Vaiana, Palermo, Italy

Development of a Monochromator System

for the X-ray Astronomy Calibration and Testing (XACT) Facility

10 Dec 2004, Mid-term Review in Milano

Page 5: 10 Dec 2004, Mid-term Review in Milano Applied Cryodetectors Research Training Network funded by the European Commission's 5th Framework programme Improving.

XACT Facility

The X ray source is a multi-anode system able to mounting up to 6 anodes and 4 filters.Flux = 105 ph/s/cm2 @ 16 meters.

Energy range: 0.1 - 20 keV: Cu(0.93; 8.04), Fe(6.4), Cr(5.41), Ti(4.51), Al(1.49), C (0.28) …

20 25 25 30 30 35 40 50 55 63 100X ray source Test chamber

100 100 100 100 100 200

20

100 200 200 200 20050100

18 m

10 Dec 2004, Mid-term Review in Milano

clean room (1000 class)

X ray source

test chamber (Ø=1 m)

Vacuum tube (10-6 mbar)

Page 6: 10 Dec 2004, Mid-term Review in Milano Applied Cryodetectors Research Training Network funded by the European Commission's 5th Framework programme Improving.

10 Dec 2004, Mid-term Review in Milano

XACT: the cryostat

Bmax = 2.3 T

1. Pumping on air (1 night)2. Pumping on LHe and LN2 (2 hours)3. Isothermal Magnetization (2 hours)4. Adiabatic Demagnetization (30 min)

Tmeas ~ 45 mK

Tpred = 43 mK30

40

50

60

DATA

Page 7: 10 Dec 2004, Mid-term Review in Milano Applied Cryodetectors Research Training Network funded by the European Commission's 5th Framework programme Improving.

What I am doingMonochromator system for

XACT facility

•The system will provide a monochromatic beam in the full energy range: 0.1 - 20 keV;

•Energy resolution: E / E = 10% ;

•Fixed position of the monochromatic beam at all energies;

•It is based on double Bragg diffraction;

•Beam section: 60 x 60 cm2 @ 20 meters;

•We plane to mount the system soon and to run the first tests in January 2005.

Some results

10 Dec 2004, Mid-term Review in Milano

Page 8: 10 Dec 2004, Mid-term Review in Milano Applied Cryodetectors Research Training Network funded by the European Commission's 5th Framework programme Improving.

Applied Cryodetectors

Network contract (HPRN-CT-2002-00322)Research Training Network

5th Framework programme: Improving Human Potential

Microcalorimeter array development for

X-ray astronomy

CEA / DSM-DAPNIA / SAp(Commisariat à l’Energie Atomique / Direction des Science de la

Matière- Dep. Astrophysique,Particule, Nucléaire et Instrumentation Associée / Service d’Astrophysique)

10 Dec 2004, Mid-term Review in Milano

Page 9: 10 Dec 2004, Mid-term Review in Milano Applied Cryodetectors Research Training Network funded by the European Commission's 5th Framework programme Improving.

CEA/SAp-calorimeter array development

for X-ray astronomyPhilosophy: realisation of a -calorimeter from the modification of existing bolometer arrays for IR instruments.

Advantages: tested standard collective silicon technologies.

The sensor will be adapted increasing the implanted dose (Phosphorus, 40% Boron compensation) from 1-10 G @ 300 mK° to 1-10 M @ 50-100 mK°.

Absorber candidate: Tantalum.

Indium bump hybridization process allows a self alignment between the absorbers and the sensors.

10 Dec 2004, Mid-term Review in Milano

Oxide simox

Removed CdTe substrate

High Z

sensor plate

Etching of SOI dioxide back and front side

Removed Silicon substrate

High Z superconductor

glue

Page 10: 10 Dec 2004, Mid-term Review in Milano Applied Cryodetectors Research Training Network funded by the European Commission's 5th Framework programme Improving.

calorimeter 2D arrayResistive Mesa Si thermometerSilicon Micro-etching technology

6- Al Deposit and Etchingon the thermo contacts.

Scheme of the MESA process on a double SOI substrate

1-ThermometerImplantation

2-Diffusion of the thermometer implantation

3-Contact Implantationand Diffusion

4-Etching of theThermometer

5-Etching of the first SOIdioxide

Microcalorimeter structure

10 Dec 2004, Mid-term Review in Milano

Page 11: 10 Dec 2004, Mid-term Review in Milano Applied Cryodetectors Research Training Network funded by the European Commission's 5th Framework programme Improving.

CEA/DTA/LETIGrenoble, France.Microcalorimeter

CEA/DSM/DAPNIA/Edelweiss groupSaclay, France. Dilution Cryostat Setup

Synergy

CEA/DSM/DAPNIA/SAp, Saclay, France.

10 Dec 2004, Mid-term Review in Milano

25 m thick Ta foil glued on sensor plate

Wafer

Matrix

Page 12: 10 Dec 2004, Mid-term Review in Milano Applied Cryodetectors Research Training Network funded by the European Commission's 5th Framework programme Improving.

Acquisition data setup

•TRMC2: Temperature Regulator and Measurement Controller 2.• PC1: TRMC2 interface. PC1-PC2 link is established only during test campaign.•PC2: acquisition data; it has read/write permission on PC1

Internet link

10 Dec 2004,Mid-term Review in Milano

Relay board high insulation

Page 13: 10 Dec 2004, Mid-term Review in Milano Applied Cryodetectors Research Training Network funded by the European Commission's 5th Framework programme Improving.

Measurements

01

02 0504

01

0504

02

•15 sensor / 4 matrix of the same wafer.•3.75 1018 atoms/cm3 P implantation, B 40%

compensation.•Gap betweens curves circular implantation•“04” Curve fitting (Efros and Shklovskii):R = R0e(T0/T); R0 = 6 k, T0 = 40 K, = 0.48

10 Dec 2004, Mid-term Review in Milano

thermistorHeatingresistor

Feedback resistor

Page 14: 10 Dec 2004, Mid-term Review in Milano Applied Cryodetectors Research Training Network funded by the European Commission's 5th Framework programme Improving.

Conclusions10 Dec 2004, Mid-term Review in Milano

The mobility of the researchers can give the opportunity to establish fruitful international contacts and collaborations. Some examples in my experience:

Symbol X: CEA/SAp, Saclay, Paris (H.E. detector) – Osservatorio Astronomico di Brera, Milano, Italy (X ray optics);

Bolometers: CEA/SAp, Saclay, Paris (micro calorimeter technology) – INAF/Osservatorio Astronomico G.S. Vaiana, Palermo, Italy (absorber tests and modeling);

Fixed Exit Beam Monochromator: CEA/SAp, Saclay, Paris (experience in monochromator elements) - INAF/Osservatorio Astronomico G.S. Vaiana, Palermo, Italy (Monochromator design and construction);

Page 15: 10 Dec 2004, Mid-term Review in Milano Applied Cryodetectors Research Training Network funded by the European Commission's 5th Framework programme Improving.

Article

•Development of a microcalorimeter array for wide energy band X-ray astronomy Pelliciari, C. / Agnese, P. / Navick, X.F. / Pigot, C. / Sauvageot, J.L., Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Mar 2004

• Microcalorimeter array development for X-ray astronomy Pigot, C. / Agnese, P. / Navick, X.F. / Pelliciari, C. / Sauvageot, J.L., Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, May 2003

Page 16: 10 Dec 2004, Mid-term Review in Milano Applied Cryodetectors Research Training Network funded by the European Commission's 5th Framework programme Improving.

Monochromator elementsEnergy range: from 10 up to 20 keV few fluorescence lines continuum

Energy range: from 0.1 up to 10 keV fluorescence lines;

We investigated several materials as candidate for monochromators with different geometry (flat, concave and convex with different curvature radius). Monochromator/energy (keV)

0.1 0.3 0.5 0.7 1.0 2.0 5.0 10.0 20.0

Graphite mosaic 0.4°

Graphite mosaic 3.5°

Silicon, Germaniummosaic 120”

TlAP (organic)

Multilayers (Mo/Si, W/Si)

Gratings

?10 Dec 2004, Mid-term Review in Milano

Page 17: 10 Dec 2004, Mid-term Review in Milano Applied Cryodetectors Research Training Network funded by the European Commission's 5th Framework programme Improving.

Simulation results = standard deviation of mosaic distribution;• = 2.355 ;• B = Bragg angle;• r concave/convex = curvature radius 1st and 2nd crystal;• xl z dim: z crystal dimension (mm);• xls prj: crystal dimension projection (seen from source) • div (rad): angular spread

10 Dec 2004, Mid-term Review in Milano

Page 18: 10 Dec 2004, Mid-term Review in Milano Applied Cryodetectors Research Training Network funded by the European Commission's 5th Framework programme Improving.

Beam features: Graphite

10 Dec 2004, Mid-term Review in Milano

monochromator