8/8/2019 1. Model #8500 Articulator
1/67
Model #8500 Articulator
8/8/2019 1. Model #8500 Articulator
2/67
The Whip Mix Articulator, Model #8500
8/8/2019 1. Model #8500 Articulator
3/67
Positioning Nasion Relator on crossbar of face-bow.
8/8/2019 1. Model #8500 Articulator
4/67
QUICKMOUNT Face-Bow inposition on human skull.
8/8/2019 1. Model #8500 Articulator
5/67
Shows relation of face-bow earpiece to condyle.
8/8/2019 1. Model #8500 Articulator
6/67
While face-bow is in place, the condylar width is determined by
marking on front of face-bow-medium in this instance.
8/8/2019 1. Model #8500 Articulator
7/67
Condyle elements are moved to center holes of lower frame to
correspond to themedium registration.
8/8/2019 1. Model #8500 Articulator
8/67
To adjust the upper frame of the articulator to the medium width,
one spacer is removed from the shaft of the condylar guide on
each side.
8/8/2019 1. Model #8500 Articulator
9/67
The condylar guides are set at 30 angulation in preparation for
receiving face-bow registration.
8/8/2019 1. Model #8500 Articulator
10/67
The QUICKMOUNT face-bow registration of the maxillary teeth
is locked in position.
8/8/2019 1. Model #8500 Articulator
11/67
Transferring the face-bow registration to the articulator:
The holes in the earpieces are placed onto the pins extending
from the condylar guides of the articulator.
8/8/2019 1. Model #8500 Articulator
12/67
Holding the face-bow arms firmly in place, the three locking
screws are tightened.
8/8/2019 1. Model #8500 Articulator
13/67
The lower frame of the articulator is used as a support for the
face-bow registration and upper frame of the articulator while
mounting the upper cast.
8/8/2019 1. Model #8500 Articulator
14/67
The upper cast is placed into the registration of the face-bow
8/8/2019 1. Model #8500 Articulator
15/67
While supporting the face-bow fork, the upper arm of the
articulator is brought down until it touches the cross member of
the face-bow.
8/8/2019 1. Model #8500 Articulator
16/67
When Mounting Stone has hardened, the Incisal guide pin is
replaced in the upper member of the articulator.
8/8/2019 1. Model #8500 Articulator
17/67
The line that completelyencircles the guide pin, when
flush with the top of its
supporting bushing, sets
parallel the upper and lower
arms of the articulator.
This pin should be set a 5mm
opening in preparation for
mounting lower cast.
Place round end of pin down
if plastic incisal guide is used.
8/8/2019 1. Model #8500 Articulator
18/67
If the Adjustable Incisal
Guide is used, the chisel
shaped end of the guide pin
is used.
The guide is positioned so
that the chisel edge of the pin
rests on the small indentation
in the center of the table.
8/8/2019 1. Model #8500 Articulator
19/67
The Incisal Guide Table is then locked into place with the hex
driver used with the face-bow.
8/8/2019 1. Model #8500 Articulator
20/67
With the articulator inverted and using a centric relation
registration, the lower cast is positioned onto the upper cast and
Mounting Stone applied to the cast and mounting plate.
8/8/2019 1. Model #8500 Articulator
21/67
The lower frame is then pushed into place until the Incisal guide
contacts the guide pins.
8/8/2019 1. Model #8500 Articulator
22/67
Front view of the skull with the two jaws in centric relation.
8/8/2019 1. Model #8500 Articulator
23/67
Side view showing position of condyles when mandible is in
centric relation.
8/8/2019 1. Model #8500 Articulator
24/67
Front view with mandible in left lateral excursion. Wax
registration of this movement is in place between the upper and
lower teeth.
8/8/2019 1. Model #8500 Articulator
25/67
Left side view with mandible in left lateral excursion, the left
condyle remains in retruded position.
8/8/2019 1. Model #8500 Articulator
26/67
Right side view at the same time the right condyle moves down
and forward.
8/8/2019 1. Model #8500 Articulator
27/67
With this same lateral excursion registration transferred to the
articulated casts, the right condyle of the articulator moves down
and forward correspondingly. (Side plate of guide has been cut
away to improve view)
8/8/2019 1. Model #8500 Articulator
28/67
To set this inclined movement into the articulator, the condylar
guide is rotated downward until it touches the condyle element,
then locked into position.
8/8/2019 1. Model #8500 Articulator
29/67
The side shift guide is moved laterally until it also contacts the
right condyle elements, and locked into position.
8/8/2019 1. Model #8500 Articulator
30/67
Slide shift in position.
8/8/2019 1. Model #8500 Articulator
31/67
Left condyle has moved away from its side shift guide.
8/8/2019 1. Model #8500 Articulator
32/67
Front view of the skull with mandible in right lateral excursion.
8/8/2019 1. Model #8500 Articulator
33/67
In this movement, the right condyle remains in its retruded
position.
8/8/2019 1. Model #8500 Articulator
34/67
The left condyle moves forward and down.
8/8/2019 1. Model #8500 Articulator
35/67
This registration is transferred to
the articulated casts and the leftside guidance of the instrument is
adjusted in the same manner as the
right side.
8/8/2019 1. Model #8500 Articulator
36/67
The skull and articulated casts are both in left lateral excursion position,
but with the inclination of the eminentia set at an arbitrary angle slightly
less on the articulator than that of the skull. The second and third
molars of the casts are in closer relationship than are those of the skull.
8/8/2019 1. Model #8500 Articulator
37/67
With the articulator set at a slightly greater angle than exists in
the skull, this piece is greater on the casts than it is on the skull.
8/8/2019 1. Model #8500 Articulator
38/67
Front view of articulated casts and skull, comparing the two while
in left lateral excursion. (Settings of articulator are correct as
registered by wax transfers)
8/8/2019 1. Model #8500 Articulator
39/67
View comparing the two while in right lateral excursion.
8/8/2019 1. Model #8500 Articulator
40/67
Side view of the two while in partial lateral excursion.
8/8/2019 1. Model #8500 Articulator
41/67
Permanent Incisal guide registration may be obtained by cutting
guide path into plastic Incisal guide block.
8/8/2019 1. Model #8500 Articulator
42/67
Double exposure, superimposing the lower frame of the articulator,
in corresponding position of the mandible, over the skull.
8/8/2019 1. Model #8500 Articulator
43/67
With the mandible removed, the skull is set in place onto the
lower member of the articulator.
8/8/2019 1. Model #8500 Articulator
44/67
With the lower casts mounted on the articulator frame, it
replaces the mandible of the skull.
8/8/2019 1. Model #8500 Articulator
45/67
Front view of entire articulator with mounting stone in place,
superimposed by double exposure, over skull.
8/8/2019 1. Model #8500 Articulator
46/67
Front and side views of skull and articulated casts.
8/8/2019 1. Model #8500 Articulator
47/67
Dentoforms mounted on articulator, showing writing stylus in
place in an attempt to trace articulator movements to compare
different adjustments of the instrument.
8/8/2019 1. Model #8500 Articulator
48/67
Close-up showing method of mounting ball-point pen refill with self-
curing plastic to allow only vertical movement of the writing pen.
8/8/2019 1. Model #8500 Articulator
49/67
Flat shim of fused porcelain
was luted to the surface of
ground away lower molar
tooth with tacky sticky wax toreceive ink markings.
With dentoforms in centric
relation, the stylus rests on
the approximate center of thelower left first molar tooth.
Moving the articulator into
right lateral excursion will
draw a line from center tobuccal of tooth.
Left lateral excursion will
mark from center to lingual of
tooth.
8/8/2019 1. Model #8500 Articulator
50/67
The various paths caused by
changing only the amount of sideshift allowed, as indicated on the
individual slides.
8/8/2019 1. Model #8500 Articulator
51/67
With amount of side shift constant but changing the condylar
width.
8/8/2019 1. Model #8500 Articulator
52/67
With no side shift allowed,but again altering the
condylar width.
8/8/2019 1. Model #8500 Articulator
53/67
Composite of several paths caused by changing the condylar
width and the amount of side shift in various combinations.
8/8/2019 1. Model #8500 Articulator
54/67
Close-up views of front and bothsides of the articulated casts in
centric relation.
8/8/2019 1. Model #8500 Articulator
55/67
With the casts forced into left lateral excursion, but with no
angulation of the eminentia, the third molars on the right side are
in heavy contact.
8/8/2019 1. Model #8500 Articulator
56/67
No other teeth come close to meeting.
8/8/2019 1. Model #8500 Articulator
57/67
Setting the inclination to the average 30, the upper right
second and third molar contact the right lower third molar.
8/8/2019 1. Model #8500 Articulator
58/67
The teeth on the left side are much closer, but still no actual
contact.
8/8/2019 1. Model #8500 Articulator
59/67
The check bite registration taken from the skull set the condylar
guidance at 42 inclination. At this setting, the molar teeth on
the right side come close into a very light contact.
8/8/2019 1. Model #8500 Articulator
60/67
While the teeth on the left side are in the best occlusion possible
for these worn teeth.
8/8/2019 1. Model #8500 Articulator
61/67
With the inclination increased to 60, none of the teeth on the
right side come close to each other.
8/8/2019 1. Model #8500 Articulator
62/67
While on the left side only the cuspids make contact.
8/8/2019 1. Model #8500 Articulator
63/67
In an effort to check the authenticity of this 43 setting, a strip
of marking tape was applied to the right side of the skull crossing
the condyle at a right angle to the arm of the face-bow while it
was in place on the skull.
8/8/2019 1. Model #8500 Articulator
64/67
The marking tape was cut in two at point centered over the
condyle.
8/8/2019 1. Model #8500 Articulator
65/67
The mandible is moved into the left lateral exclusion position.
8/8/2019 1. Model #8500 Articulator
66/67
A protractor placed in relation to the two ends of the cut tape
indicates 42 . Close up of the protractor straight edge in
relation to the end of the cut marking tape.
8/8/2019 1. Model #8500 Articulator
67/67