Page 1: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

1

KX-TD500 Technical Training Seminar

Page 2: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

2

Table of Contents

Introduction 1-7KX-TD500 Basic and Expansion Shelf 8-19Configuration 20-23CPU Card KX-TD50101 24-27TSW Card KX-TD50102 28-32KX-TD500 Cards 33-59Activity One 60System Startup 61-65Activity Two 66Hardware Addresses 67-73Port Status 74-79Maintenance Console Software 80-90

Page 3: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

3

Table of Contents

Activity Three 91Activity Four 92-98Activity Five 99Activity Six 100Activity Seven 101-102T1 103-122Activity Eight 123-128Activity Nine 129

Page 4: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

4

KX-TD500

Page 5: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

5

Course Outline Day 1

Introduction KX-TD500 Hardware and Configuration System Specifications System Installation System Installation Lab System Startup System Startup Lab Hardware Addressing and Port Status Maintenance Consoles Software Maintenance Consoles Software Lab

Page 6: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

6

Course Outline Day 2

KX-TD500 Features Basic Programming Lab Toll Restriction Lab ARS Lab Voice Processing Integration Lab

Page 7: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

7

Course Outline Day 3

T1 T1 Lab Remote Programming Remote Programming Lab Final Exam

Page 8: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

8

KX-TD500Digital Super Hybrid

This TD-based system will offer a smooth upgrade path for 2-cabinet TD1232 users as well as a starter system for the medium-sized businesses or high-end residential users

Page 9: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

9

KX-TD500Digital Super Hybrid

The system will provide the TD dealers with a larger system size, but offer a similar programming and user interface as currently offered by the TD308/816/1232.

The major differences between the existing TD line of systems and the KX-TD500 includes a new Windows-based programming tool, and the universal slot design.

Page 10: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

10

KX-TD500 System Outline

The KX-TD500 consists of a basic shelf and up to two expansion shelves.

The systems features a universal slot design enabling station, CO, and other function cards to be installed into free slots in the cabinets.

Page 11: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

11

Basic ShelfKX-TD500

The Basic Shelf is the initial building-block of the KX-TD500 system allowing a single-cabinet system to be configured with up to a maximum of 192 ports.

The Basic Shelf then provides the foundation on which the system can be expanded by use of expansion shelves to configure a system up a maximum of 512 ports.

Page 12: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

12

Basic ShelfKX-TD500

The Basic Shelf houses the system’s common control cards including the Central Processing Unit (CPU) card and the Time Switch (TSW) card.

Only the TSW card is included with the Basic Shelf which includes the DOHCA and TSW-CONF cards

The CPU card is available separately.

Page 13: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

13

Basic ShelfKX-TD500

12 Free Slots (FS1-FS12) are available in the Basic Shelf and can be carded with CO, station, or other function cards as required by the installations application.

If the installation location requires more than the 12 slot configuration supports, the system can be expanded by attaching 2 additional Expansion Shelves to the upper portion of the Basic Shelf

Page 14: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

14

Basic Shelf Includes:

Top panel with 3 LED indicators (Run, Offline, Alarm)

2 Female RS-232C connectors One for Programming One for SMDR

An AC Power connector

Page 15: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

15

Basic Shelf Includes:

Primary AC Power Supply with: Main Power Switch Grounding Terminal AC outputs for Expansion Shelves

Shelf Power Supply with: Power Switch Power LED Indicator Fuse KX-A46 interface connector

Page 16: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

16

Basic Shelf Includes:

Shelf Cooling FanSLT Ring GeneratorMounting BracketsSide PanelsLower PanelFront Door with Lock

Page 17: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

17

Expansion ShelfKX-TD520

The KX-TD520 Expansion Shelf can be installed onto the Basic Shelf adding on a maximum of 224 additional ports. This provides a two-cabinet system with a maximum configuration of 416 ports.

A second Expansion Shelf could then be added bring the system up to its maximum port configuration of 512 ports.

Page 18: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

18

Expansion Shelves Include:

14 Free Slots (FS1-FS14)A Shelf Power Supply with:

Power Switch Power LED Indicator Fuse KX-A46 Interface Connector

Shelf Cooling FanSLT Ring Generator

Page 19: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

19

Expansion Shelves Include:

Side PanelsFront Door with LockData and Power Connecting Cables Mounting Hardware

Page 20: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

20

Maximum System Configurations

Although the systems model number is the KX-TD500, the actual maximum system configuration can be 512 ports.

This port configuration cannot be exceeded.

Page 21: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

21

Maximum System Configurations

Things to remember about system configuration 512 ports/system is the maximum allowed 448 extensions/system is the maximum allowed 192 CO Lines/system is the maximum allowed 216 PT, SLT, & CO ports/expansion shelf 192 PT and SLT ext./shelf is the max. allowed 128 PT/Shelf is the maximum allowed 160 SLT/Shelf is the maximum allowed

Page 22: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

22

System Configuration Example 1

Expansion Shelf 2 4 DLC x 16 ports =4 LCOT x 8 ports =6 FS for option cards

64 ports32 ports96 ports total

Expansion Shelf 1 8 DLC x 16 ports =4 ESLC x 16 ports =2 LCOT x 8 ports =

128 ports64 ports16 ports208 ports total

Basic Shelf 8 DLC x 16 ports =4 ESLC x 16 ports =

128 ports64 ports192 ports total

Final system configuration of (48) CO lines and (448) extensions (320 DPT & (128) SLT) = (496) Total

Page 23: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

23

System Configuration Example 1

41 - 48 CO = 6 LCOT (ELCOT)305 - 320 DPT = 20 DLC113 - 128 SLT = 8 ESLC34 out of 40 Free Slots used496 out of 512 ports used (16 avail.)XDP, Parallel Telephones or APT

require DHLC

Page 24: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

24

Expansion Shelf 2 8 DLC x 16 ports =2 T1 x 24 ports =

128 ports48 ports176 ports total

Expansion Shelf 1 5 DLC x 16 ports =3 T1 x 24 ports =

80 ports72 ports152 ports total

Basic Shelf 3 DLC x 16 ports =3 T1 x 24 ports =

48 ports72 ports120 ports total

Final system configuration of 192 T1 channels and 256 DPT extensions 448 Total

System Configuration Example 2

Page 25: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

25

System Configuration Example 2

169 - 192 T1 Channels = 8 T1241 - 256 DPT = 16 DLC32 out of 40 Free Slots used448 out of 512 ports used (64 avail.)

Page 26: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

26

KX-TD50101 CPU Card

386-based Main Central Processing Unit Card residing in the Basic Shelf

This card provides control and call processing data for all system functions including TSW control, power down and system clock alarms

Main components include 80386 CPU, RAM, ROM, memory backup lithium battery

Page 27: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

27

KX-TD50101 CPU Card

CPU card also includes circuitry for the RS-232C connectors

“System” and “Mode” switches are 10 position rotary switches located on the front edge of the CPU card along with the push reset switch.

The “System” switch is not used in the US version.

Page 28: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

28

KX-TD50101 CPU Card

The “Mode” switch is used to determine the startup condition of the system. Although it is a 10 position switch, only 4 position are utilized for normal operations.

Page 29: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

29

KX-TD50101 CPU Card

Mode switch positions are: Position 1 On-line while holding current data Position 0,2,3,9 On-line Same function as 1 Position 4 Off-line holding current data Position 5 Off-line while defaulting system Position 6 ON-LINE with “backdoor” password Position 7 Off-line factory finished product testing Position 8 Off-line factory finished product testing

Page 30: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

30

KX-TD50102 TSW Card

The Time Switch (TSW) card provides the systems voice switching matrix including 72 3- party conferencing circuits

The TSW card generates all audible call progress tones, including dial tone, busy tone, reorder and ringback tones

Page 31: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

31

KX-TD50102 TSW Card

The TSW card also provides an interface for 2 Music on Hold inputs (9/64” mini-plug) and 2 External Paging output jacks (RCA plugs) with volume adjustments

Two daughter boards are attached to the TSW card KX-TD50104 KX-TD50105

Page 32: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

32

TSW Cards

The KX-TD50104 TSW-CONF Expansion Card adds an additional 64 3-party conference circuit to the basic 8 provided by the TSW card

The KX-TD50105 DOHCA card allows for OHCA for Digital Proprietary station cards

Both of these cards play an important role in Digital Voice Mail integration

Page 33: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

33

TSW Card

The KX-TD50104 TSW-CONF card provides 3-party conferencing capability. This includes the three DPITS integration features Two-way Record, Two-way Transfer, and Live Call Screening.

Each of these features requires the use of conference circuit

Page 34: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

34

TSW Card

The KX-TD50105 DOHCA card provides for DPT OHCA by providing TSW circuitry to support the second “B” channel for DPT telephones and DPITS integrated voice mail ports

The KX-TD50105 DOHCA card must be installed for DPITS voice mail integration to work

Page 35: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

35

New KX-TD500 Cards include:

These cards will only operate in a KX-TD500KX-TD50170-Digital Hybrid Line Card (DHLC)KX-TD50172-Digital Line Card (DLC)KX-TD50175-Enhanced Single Line Card (ESLC)KX-TD50180-Enhanced Loop Central Office

Trunk (ELCOT)KX-TD50197-Enhanced Remote Card (ERMT)

Page 36: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

36

KX-TD50170Digital Hybrid Line Card

The DHLC supports 8 analog proprietary telephones or 8 digital proprietary and 8 SLT telephones (XDP or parallel)

This card supports 7000 and 7400 series telephones as well as SLT’s

See right side of page 2-41 in Installation Manual for block wiring

Page 37: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

37

KX-TD50170Digital Hybrid Line Card

OHCA using the KX-T7436/7130 is supported without any additional cards installed on the station card. (The KX-TD50105 card must be installed on the TSW card for OCHA to the KX-T7436)

Page 38: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

38

KX-TD50172Digital Line Card

The DLC supports 16 digital proprietary telephones (7400 series) and DSS consoles

No SLT’s are will operate on this cardSee right side of page 2-44 in

Installation Manual for block wiring

Page 39: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

39

KX-TD50175Enhanced Single Line Card

The ESLC supports 16 single line telephones with Message Waiting Lamp compatibility

No proprietary telephones will operate on this card

ESLC has 4 DTMF receiversSee right side of page 2-42 in

Installation Manual for block wiring

Page 40: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

40

KX-TD50180Enhanced Loop CO Trunk

The ELCOT card supports 8 Loop Start Central Office lines

When two optional KX-TD193 Caller ID cards are installed, Central Office Caller ID is provided to proprietary display telephones

See page 2-55 in Installation Manual for block wiring

Page 41: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

41

KX-TD50197Enhanced Remote Card

The ERMT card is a modem card (V.34) used for remote administration.

Page 42: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

42

Other Cards Supported by the KX-TD500

The following cards were previously supported by the KX-T336, and in the case of the KX-TD193, the KX-TD816/1232, and provide the same functions and capabilities.

Refer to KX-TD500 optional card compatibility chart for more information

Page 43: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

43

Other Cards Supported by the KX-TD500

KX-T96170 - 8 Station Hybrid Line Card (HLC) KX-T96172 - 8 Station Proprietary Line Card

(PLC) KX-T96174 - 8 Station Single Line Card (SLC) KX-T96175 - 8 Station Single Line Card with

Message Waiting Lamp compatibility (SLCM) KX-T96180 - 8 Loop Start Central Office Trunk

card (LCOT) KX-T96181 - 8 Ground Start Central Office Trunk

card (GCOT)

Page 44: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

44

Other Cards Supported by the KX-TD500

KX-T96182 - 4 DID Trunk card (DID) KX-T96185 - 4 Station Off-Premise extension

card (OPX) KX-T96186 - Off Premise Extension Power Unit KX-T96187 - T1 card (T1) KX-T96161 - Doorphone card (DPH) KX-T96191 - DISA card (DISA) KX-T96193 - Automatic Gain Control card

(AGC)

Page 45: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

45

Other Cards Supported by the KX-TD500

KX-T96196 - 1200 bps Remote card (RMT)

KX-T96136 - OHCA card for HLC and PLC cards (OHCA)

KX-TD193 - Caller ID card for ELCOT card (CID)

Page 46: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

46

KX-T96170

Hybrid Line Card (HLC)Each card provides 8 Hybrid extension

portsEither a Analog Proprietary Telephones

(7000 series) or a single line telephones can be connected to this card

See right side of page 2-41 in Installation Manual for block wiring

Page 47: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

47

KX-T96172

Proprietary Line Card (PLC)Each card provides 8 proprietary

extension portsOnly Analog Proprietary Telephones

(7000 Series) can be connected to this card

See right side of page 2-41 in Installation Manual for block wiring

Page 48: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

48

KX-T96174

Single Line Telephone card (SLC)Each card provides 8 single line

extension portsOnly single line telephones can be

connected to this cardSee right side of page 2-41 in

Installation Manual for block wiring

Page 49: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

49

KX-T96175

Single Line Card with Message Waiting (SLC-M)

Each card supports 8 single line extensions with Message Waiting lamps

See right side of page 2-41 in Installation Manual for block wiring

Page 50: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

50

KX-T96180

Loop Start Central Office Card (LCOT)Each card allows 8 Loop Start Central

Office lines to be connected to the system

See page 2-55 in Installation Manual for block wiring

Page 51: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

51

KX-T96181

Ground Start Central Office Card (GCOT)

Each card allows 8 Ground Start Central Office lines to be connected to the system

See page 2-55 in Installation Manual for block wiring

Page 52: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

52

KX-T96182

Direct Inward Dialing Trunk Card (DID)

Each card allows 4 DID Central Office lines to be connected to the system

This card will accept pulse signaling only

System interface is modular (RJ-11C)

Page 53: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

53

KX-T96185 and KX-T96186

KX-T96185--Off Premise EXtension Card (OPX)KX-T96186--Off Premise Extension Power

SupplyAn OPX card and Power Supply provides 4

OPX single line telephones onlyBoth OPX units are required when a single line

telephone must be placed in another building or location

System interface is modular (RJ-11C)

Page 54: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

54

KX-T96187

T-1 CardUp to 8 T1 cards can be installed in the KX-

TD500Frame Formats D4/SF or ESFLine Coding AMI or B8ZSChannel Types LCO/GCO/DID/OPX/TIESystem interface is RJ-48C (See page 2-53

in Installation Manual for cable configuration)

Page 55: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

55

KX-T96187

The T1 card can only be installed in slots 1 (2), 5 (6), and 9 (10).

The slot immediately adjacent to the right of each T1 card must be left empty as indicated above by the slot number that are parenthesized.

Page 56: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

56

KX-T96161

Doorphone cardProvides 4 Doorphones and 4 dry

contact relays2 card per system

Page 57: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

57

KX-T96191

Direct Inward Station Access card (DISA)Each DISA card can be programmed to

provide one of three functions. Basic 4 port automated attendant or; Outgoing Message for Uniform Call

Distribution Timed Reminder OGM

8 DISA cards can be installed in the system

Page 58: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

58

KX-T96193

Automatic Gain Control card (AGC)Each card provides 4 gain controlled

CO to CO conference circuits8 AGC cards can be installed in the

system

Page 59: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

59

KX-T96196

Remote Administration cardAllows remote system administration

at 1200 baud1 Remote card can be installed in the

system

Page 60: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

60

KX-T96136

KX-T96136 -- Off Hook Call Announce card

1 KX-T96136 card must be installed for every 2 KX-T7130 telephones that require OHCA

A maximum of 4 KX-T96136 connects to either the PLC or HLC cards

Page 61: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

61

KX-TD193Caller ID Card

1 KX-TD193 will support 4 Caller ID compatible Central Office Lines connected to the KX-TD50180 card (ELCOT). For all eight lines to support Caller ID, a second KX-TD193 must be installed.

The KX-TD193 supports both Single and Multi-Message formats

Page 62: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

62

Activity OneShelf and Card Installation

Purpose: To assemble a shelf and install cards in a shelf

1. Install an Expansion Shelf on a Basic Shelf2. Install all cards into the Basic Shelf leaving slots

09 and 10 empty. Also make sure that slot 01 has either a DLC or DHLC installed in it. This will be necessary for practice exercises at a later time.

Page 63: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

63

System Startup Procedure

System startup or initialization must be executed for every system

The purpose of this procedure is to default the system and to automatically assign installed hardware into their respective positions

This procedure is accomplished using rotary switch labeled “Mode” on the CPU card

Page 64: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

64

System Startup Procedure1.Ensure that all cards that are to be initially

installed are properly seated in the card slots and that the cabinets are properly assembled.

2.Connect the AC power cord to the Basic Shelf and then to a properly grounded and protected AC outlet

3.Connect a ground wire to the Ground terminal (Not necessary in training environment)

4.Turn On the Main Power Switch on the Basic Shelf5.Turn On the Power Switch for each Expansion Shelf

Page 65: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

65

System Startup Procedure

6. Turn On the Power Switch for the Basic Shelf

7. Using a small flathead screwdriver, turn the Mode Switch on the CPU to position “5”. Note: Leave the System in position 0

8.Press and release the CPU Reset button9.Wait 2 minutes. After 2 minutes, the Run

light will be green and the Off-line light will slowly flash yellow.

Page 66: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

66

System Startup Procedure

10.The system is now in the Off-line mode. Only system administration can be performed.

11.Turn the Mode Switch to position “1”. It is very important that the Mode Switch be placed in position ”1” at this time. If the system were to be reset, or if the AC power were to be lost momentarily, the system would re-initialize and return to the default condition. Any programming changes that you may have been made would have been lost.

Page 67: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

67

System Startup Procedure

12.To place the system into the On-line Mode, press and release the CPU Reset button.

13.Wait 2 minutes. After the 2 minute waiting period, the system will be On-line. The Run light will be lit, and the Off-line and Alarm light will be off. Call processing can be accomplish as well as system administration in the On-line mode. Only the Upload to PBX function can not be performed

Page 68: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

68

Activity TwoSystem Startup

Purpose: To become familiar with the system startup procedure

1. Execute the system startup procedure

Page 69: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

69

KX-TD500 Hardware Addresses

The KX-TD500, like most other universal free slot designed PBX’s, utilize a numbering system to identify ports, cards, and shelf locations.

This is necessary when programming and maintaining the system

Page 70: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

70

KX-TD500 Hardware Addresses

Generally hardware address will be either 3 digit or 5 digit numbers.

Example: 10205 The first digit (1) indicates the shelf. In

this example the 1 indicates the Basic Shelf. The first expansion shelf would be identified with a 2 and the second expansion shelf identified with a 3

Page 71: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

71

KX-TD500 Hardware Addresses

Example: 10205 The next two digits (02) indicate the slot

number. In this example the card is located in the Basic Shelf in slot 2. In the Basic Shelf, valid entries would be 01-12. In the Expansion Shelves, valid entries would be 01-14

Page 72: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

72

KX-TD500 Hardware Addresses

Example: 10205 The next two digits (05) indicate the

port number. Port number identifiers will vary based on the card type. Some will have up to 16 ports, others 8 or less.

For example, a DLC is a 16 port card and would have valid entries of 01-16.

Page 73: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

73

KX-TD500 Hardware Addresses

Example: 10205 A DHLC is slightly different. The first 8

port identifiers (01-08) are used to identify the 8 proprietary ports on this card. The second 8 port identifiers (09-16) are used to identify the XDP ports. For example, port identifier 09 is used to program the XDP single line extension for port 01.

Page 74: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

74

KX-TD500 Hardware Addresses

A card with twenty-four port identifiers (01-24) is the T1 card

Cards with sixteen port identifiers (01-16) include: DLC, DHLC and ESLC

Cards with eight port identifiers (01-08) include: HLC, PLC, SLC, SLC-M, LCOT, GCOT & ELCOT

Page 75: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

75

KX-TD500 Hardware Addresses

Cards with four port identifiers (01-04) include: OPX, DID, DISA, AGC & DPH

Cards that only have no port identifier include: RMT and ERMT

Page 76: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

76

Port Status

Ports and cards can be in various states of service

Operational devices are usually In-Service or the abbreviation “INS”

Disabled devices are usually Out-of-Service or the abbreviation “OUS”

Another state is Fault. This can be caused by several things including configuration problems as well as hardware failure

Page 77: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

77

Port Status

The final state of service is called Busy-out. This occurs on CO ports that have been placed in the Busy-out state by a system administrator.

Generally the “INS” and “OUS” states are most common. Changing from one to another is accomplished by using different screens from within the KX-TD500 Maintenance Console programming tool

Page 78: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

78

Port StatusWithin the Maintenance Console

programming tool, the state of service can be identified and changed by clicking on the “Status” button. The text on the “Status” button indicates the current state, and the state can be toggled from one state, for example OUS, to the alternative state, in this case INS, by clicking on the “Status” button and then selecting OK.

Page 79: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.
Page 80: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

Port Status

Page 81: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.
Page 82: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

82

Maintenance Console Software

Proprietary PC programming softwareOperating Systems

Windows® 3.1 Windows® 95/98

PC Requirements CPU: 486 25 Mhz or better RAM: Minimum of 8 MB HDD: Minimum of 5 MB free plus 500 KB per

user file

Page 83: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

83

Maintenance Console Setup

Page 84: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

84

InstallShield® Wizard

Page 85: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

85

Maintenance Console Setup

Page 86: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.
Page 87: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.
Page 88: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.
Page 89: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.
Page 90: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

90

Td500.exe.lnk

Shortcut can be created

Page 91: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

91

Page 92: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

92

Maintenance Console Software

Page 93: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

93

Activity ThreeInstalling Software

Purpose: To become familiar with the process of installing the KX-TD500 Maintenance Console program in your PC

1. Install the KX-TD500 Maintenance Console software into your PC.

Page 94: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

94

Activity FourMaintenance Console

Purpose: To become familiar with the Maintenance Console program by connecting and disconnecting, navigating, making basic programming changes and applying them.

1. Properly connect your serial cable and null modem connector to your PC and KX-TD500 programming RS-232C

2. Open the KX-TD500 Maintenance Console program3. Establish a local connection using the default parameters of:

Port Set according to your PCNL Code CR+LFBaud Rate 9600 bpsPassword 1234

Page 95: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

95

Activity FourMaintenance Console4. Enter Programming-Interactive and allow the software to

upload programming parameters5. Browse through all available programming screens but do

not change any parameters at this time. 6. Now make your first programming changes. Ensure that a

KX-T7436 is installed on the first port (ext.1001) of the DHLC or DLC installed in slot 01. In the Line-Extension Line screen, program and apply extension 1001 to have the following CO Keys:CO 1-6 PDN buttonsCO 7-14 S-CO buttons for the 1st 8 CO’sCO 15-24 Not Stored (for now)

Page 96: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

96

Activity FourMaintenance Console

7. Next, program and apply another extension to have the following CO Keys:

CO 1-8 Single-COCO 9-18 Not Stored (for now)CO 19-20 One-Touch buttonsCO 21-24 Not Stored (for now)

8. Now copy all parameters from the above extension to all other extension other than extension 1001 that was programmed in step 6.

9. Name the first 24 extensions10. Set the Time and Date

Page 97: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

97

Activity FourMaintenance Console

11. In the Line-Trunk Line screen, name the first 8 CO’s and assign the Day and Night Destination to be 1001

12. In the Features-System Speed Dialing screen, assign 20 System Speed Dialing names and numbers

13. In the System-System Options 4/4, change the FWD/DND lamp pattern to FWD:On, DND:Flash

14. Test the operation of all applicable programming to this point.

This completes some of the basic programming changes in the interactive mode, now let’s save this configuration to the hard disk drive and make some additional changes to the file in the batch mode.

Page 98: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

98

Activity FourMaintenance Console

15. Execute the File-Download from PBX menu option16. When the Download from PBX is complete, save the

file using the Save As menu option to your hard disk drive.

17. Disconnect from the PBXNow we will modify the file while not connected to the

PBX. The changes that are made will be saved to the hard disk when complete. We will then Upload the changes to the KX-TD500

18. Using the File-Open menu option, open the file that you saved in step 16

Page 99: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

99

Activity FourMaintenance Console

19. In the Configuration-Extension Port Assignment screen, set the XDP function for all extensions on the DHLC(s)

20. Select a port on a DLC installed in your system and assign it as a DSS in the Configuration-Extension Port Assignment screen. Pair the DSS with extension 1001

21. In the Line-DSS Console screen, assign 32 DSS keys to the DSS console

Now let’s save the file again to the hard disk drive and then Upload the modified file back into the KX-TD500

22. Save the modified file to the hard disk drive once again

Page 100: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

100

Activity FourMaintenance Console

23. Using the rotary Mode Switch on the CPU card, place the system in the Off-Line Mode

24. Establish a Local Connection once again25. Open the saved file26. Execute the File-Upload to PBX menu option27. When Upload is complete, disconnect the local connection28. Using the rotary Mode Switch on the CPU card, place the

system in the On-Line Mode29. Establish a Local Connection once again and enter

Interactive programming 30. Confirm the programming that was completed in step 19-21

Page 101: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

101

Activity FiveToll Restriction

Purpose: To understand the KX-TD500 toll restriction capabilities

1.Restrict extension 1001 and 1002 from dialing 1-900, 976, 1***976, 011 and 1-411. Allow all other calls.

2. Allow extension 1003 to dial local calls and 1-800 calls only.

Page 102: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

102

Activity SixARS

Purpose: To understand the KX-TD500 Automatic Route Selection capabilities

1. Using ARS, route all outgoing CO calls over the LCOT in Trunk Group 1.

Page 103: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

103

Activity SevenDPITS Voice Mail Integration

Purpose: To understand the programming involved in integrating a Panasonic Voice Processing System using DPITS integration.

1. Make the required physical connections between your KX-TD500 and the Voice Processing System for a 2 port DPITS integrated system. This will require that one data pair from an extension port of the KX-TD500 be wired into the input jacks of the VPS using a modular cord.

2. In the Configuration-Extension Port Assignment screen, assign the extension port selected in step 1 to be VPS(DPT)

Page 104: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

104

Activity SevenDPITS Voice Mail Integration

3. In the Configuration-VPS(DPT) Port Assignment screen, assign the correct VPS Card, VPS Type, Port No. and DN and Group No. for Ext. No. 1 and 2.

4. Connect your PC to the VPS’ s RS-232C, start your communication software, and default the VPS

5. Run the VPS’s Quick Setup Utility6. Confirm by dialing the VPS port DN that DPITS

integration has been achieved.

Page 105: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

105

What is T1?

T1 is the telephone companies infrastructure (copper wire, transmission equipment,…) that provides a high speed digital telephone circuit between two points.

T1 circuits operate at a rate of 1.544 Mbps or at what is referred to as DS1

A DS1 is comprised of 24 64 Kbps* channels (DS0) plus framing overhead

* Certain line code and frame selections can reduce the available bandwidth from 64 to 56 Kbps

Page 106: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

106

T1

channels 24bits per word x 8bits 192samples/sec x 8000 user data 1,536,000 bpsframe bits + 8000line speed 1,544,000 bps

Page 107: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

107

Digital Trunking

PSTN:Local Exchange Carrier (LEC)

orInterexchange Carrier (IEC)

T1 demarc at customer premise T1 Channel Service Unit

TD500 equipped with KX-TD97187

Page 108: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

108

T1 Channel Service Unit

A T1 Channel Service Unit (CSU) is required for each T1 line that is to be connected to the KX-TD500

For a basic TD500 T1 installation, only a CSU is required.

CSU’s come in a variety of configurations based on the application and prices will vary.

Page 109: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

109

T1 Channel Service Unit

CSU Functions: It is the first piece of Customer Premise

Equipment (CPE) after Telco’s demarcation point. Provides a 100 Ω circuit termination Provides FCC Part-68 protection Initiates and facilitates loopback testing Monitors line for errors and violations Maintain 0’s and 1’s density Supports Line Coding and Framing requirements

Page 110: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

110

Adtran ESF T1 CSU ACE

Full featured T1 CSU suitable for wall or desktop use.

Front panel LCD and four user keys provides easy configuration and unit monitoring

Physical Interface RJ-48CSupports D4/SF or ESFSupports AMI or B8ZS

Page 111: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

111

What is D4/SF and ESF?

Superframe (SF) or D4, and Extended Superframe (ESF) are the two frame formats used in North America.

Frame formats are used for frame synchronization and also for line management tasks

The KX-TD500 supports either frame formats

Page 112: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

112

D4/SF

D4 or Superframe was introduced in 1974. The D4 was derived from the first Telco channel bank which utilized this type of frame formatting.

D4/SF framing consists of a superframe made up of twelve individual frames

The twelve framing bits within the superframe follow a pattern of 100011011100

Page 113: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

113

D4/SF Superframe

F1 F2 F4F3 F5 F6 F8F7 F12F11F10F9

Superframe

F Ch1 Ch2 ……... Ch24

Frame 1

F Ch1 Ch2 ……... Ch24

Frame 2

0 1 11 10 0 0

Word

0

Frame 2 framing bit

Page 114: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

114

D4/SF

D4 or SF framing uses an in-band call control method called “bit robbing” which robs the least significant bit from each of the 24 channels within the 6th and 12th frame.

This call control information is used for dialing and other line maintenance functions.

This frame format restricts the channel bandwidth to 56 Kbps rather than 64 Kbps and is used most often in voice applications.

Page 115: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

115

Extended Superframe (ESF)

Extended Superframe is the preferred method of framing since it utilizes a larger number of frames (24 frames) and requires fewer framing bits to maintain synchronization

Framing bits for frames 4, 8, 12, 16, 20, are set to the pattern of 001011 that the far end equipment synchronizes on.

Page 116: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

116

Extended Superframe (ESF)

Since fewer frames require framing bits, the excess framing bits for the other frames can be used for other functions such as Cyclic Redundancy Checks and for an Embedded Operations Channel

The Embedded Operation Channel is an Out-of-Band call control method used for signaling, dialing, diagnostics as well as other functions.

Page 117: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

117

Extended Superframe

F1 F2 F4F3 F5 F6 F8F7 F12F11F10F9

Extended Superframe

F13 F14 F15

E

C

F

EE EEEEE

C C CFFF

E = Embedded Operations channel bitC = Cyclic Redundancy Check bitF = Framing bit

Only 15 of the 24 frames are shown

Page 118: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

118

Extended Superframe (ESF)

ESF should be used whenever possible since it has a more sophisticated diagnostic and maintenance capability and allows for a 64 Kbps channel bandwidth.

Page 119: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

119

What is AMI and B8ZS?

Alternate Mark Inversion and Binary 8 Zero Substitution are the two Line Coding formats used in North America for T1 lines

The purpose of Line Coding is to maintains synchronization by ensuring that no more than 7 consecutive “0’s” are transmitted within a DS0.

Page 120: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

120

Unipolar Signaling Used internally within most DTE equipment such as the KX-TD500 and computers

Bipolar Alternate Mark Inversion T1 lines utilize this type of signaling format

Signaling Formats

+5 v

0 v

0 1 1 0 0 1 0 0

+3 v

0 v

-3v

0 1 1 0 0 1 0 0

Page 121: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

121

AMI Line Coding

AMI get around the 1’s density requirement by forcing a 1 into the bit stream or what is called “bit stuffing.” The CSU accomplished this task by inserting a 1 into the least significant bit location.

The draw back to this method is that it reduces the available user bandwidth to 56 Kbps

Page 122: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

122

AMI Line Coding

+5 v

O v

-5 v

0 0 0 0 0 0 0 0

DTE Sends

+5 v

O v

-5 v

0 0 0 0 0 0 0 1

CSU setfor AMI sends

Page 123: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

123

B8ZS Line Coding

Binary 8 Zero Substitution is the most popular Line Coding technique used in North America.

B8ZS uses a method of inserting a particular bit pattern which includes intentional bipolar violations to replace a series of 8 “0’s”

This is the preferred Line Coding technique since it allows for 64 Kbps

Page 124: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

124

B8ZS Line Coding

+5 v

O v

-5 v

1 0 0 0 0 0 0 0 0

DTE Sends

+5 v

O v

-5 v

1 0 0 0 B 1 0 B 1

CSU setfor B8ZS sends

Previous Word

B = Bipoalar Violation

Page 125: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

125

Activity Number EightInstalling T1 Lines

Purpose: To become familiar with the installation of a T1 cards in the KX-TD500 and to be able to program the system accordingly. One T1 line has been installed at your location with the following configuration:Line Coding B8ZS

Framing ESFChannels 01-12 LCO See workstation notes for numbersChannels 13-20 GCO See workstation notes for numbers Channels 21-24 DID (E&M Immediate with DID enabled)

DID digits transferred = Last four See workstation notes for numbers

Page 126: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

126

Activity Number EightInstalling T1 Lines

1. Install a KX-T96187 card in slot 09. Refer to Installation Manual page 2-52, confirm SW5 (jumper) is in the correct position for the KX-TD500.

2. In the Configuration-Slot Assignment screen, assign a T1 card in slot 09

3. In the Configuration-Slot Assignment screen, click on slot 09 T1, and the Properties. Ensure the Line Coding and Frame Sequence is set to B8ZS and ESF.

4. In the Configuration-Slot Assignment screen, click on slot 14 TSW. Set the Clock Configuration Mode to External and Clock Configuration Priority to 109:T1

Page 127: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

127

Activity Number Eight Installing T1 Lines

5. Change the Status to INS6. Connect the T1 line to the NET jack of the CSU.

Connect the RJ-48C cable to the T1 card, the other end to the CPE jack of the CSU

7. Using the display and the four front panel buttons on the CSU, verify that in the CONFIG-NETWORK (NI) display that the Format and Code are set to ESF and B8ZS

8. The CSU Power LED should be lit and all other LED’s are off. The SYNC LED on the KX-TD96187 should flash slowly. If this is not the case, check the CSU and Configuration-Slot Assignment settings.

Page 128: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

128

Activity Number Eight Installing T1 Lines

9. Now, in the Configuration-T1 Port Assignment screen, assign the proper Channel Type

Channels 01-12 LCO Trunk Group 02

Channels 13-20 GCO Trunk Group 03Channels 21-24 TIE (E&M) Trunk Group 04

10. Place each channel INS11. On extension 1001, assign eight Single-CO buttons to CO

Keys 15-22 for Trunk Lines 10901-10904, and 10913-10916. Verify that you are able to draw dial tone for each of these lines.

12. Set up a ringing pattern of your choice for each of these lines and test

Page 129: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

129

Activity Number Eight Installing T1 Lines

13. In the Line-Trunk Line screens for 10921-10924, verify that the Incoming Type is set to “TIE”, the DID/TIE-Delete Digits is set to “O Digit”, Insert Dial is blank, and the Start Signal Type is “Immediate.”

14. Using the DID addresses provided at your work station, seize a Single-CO and make test calls to verify that the the extension that rings has the matching extension number of the last four digits of the number dialed. When other workstations are ready to receive test T1 DID type calls, make calls from workstation to workstation.

Page 130: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

130

Activity Number Eight Installing T1 Lines

15. Change the ARS routing so that the T1 channels (Trunk Group 2) are seized as a first priority for outgoing calls, and the LCOT in trunk group 1 are seized as a second priority.

Page 131: 1 KX-TD500 Technical Training Seminar. 2 Table of Contents Introduction1-7 KX-TD500 Basic and Expansion Shelf8-19 Configuration20-23 CPU Card KX-TD5010124-27.

131

Activity Number Nine Utility and Diagnostics

Purpose: To become familiar with the process of running diagnostic tests and checking status and error logs

1. Run various diagnostic test2. Check the error and status screens