1. GENERAL INFORMATION VD011E_19--CHAPTER01 2012.06.20
CONTENTS
1. GENERAL INFORMATION1-1. FEATURES OF SYSTEM .......................................................... 01-01
1-1-1. HIGH EFFICIENCY OPERATION....................................................................01-01
1-1-2. HIGH DESIGN FREEDOM ..............................................................................01-03
1-1-3. HIGH RELIABILITY.........................................................................................01-05
1-1-4. EASY INSTALLATION ....................................................................................01-07
1-1-5. MORE COMFORT & CONVENIENCE............................................................01-09
1-1-6. EASY SERVICE & MAINTENANCE ...............................................................01-11
1-2. MODEL LINE UP....................................................................... 01-13
1-2-1. OUTDOOR UNIT .............................................................................................01-13
1-2-2. INDOOR UNIT .................................................................................................01-15
1-2-3. CONTROLLER................................................................................................01-17
1-2-4. ADAPTOR / CONVERTOR / MAINTENANCE................................................01-18
1-2-5. OUTDOOR UNIT BRANCH KIT......................................................................01-19
1-2-6. SEPARATION TUBE .......................................................................................01-19
1-2-7. HEADER..........................................................................................................01-20
1-2-8. EV KIT .............................................................................................................01-21
1-2-9. CASSETTE GRILLE........................................................................................01-21
1-2-10.OTHERS (optional parts)..............................................................................01-22
1-3. REVISION CODE ...................................................................... 01-24
FEATURES OF SYSTEM1-1.HIGH EFFICIENCY OPERATION1-1-1.
SIGNIFICANTLY IMPROVED EER/COP �Significantly greater efficiency is realized by the use of a DC twin rotary compressor, inverter technology, and large heat exchanger.
ENERGY SAVING TECHNOLOGY �
The data refers to a 8HP outdoor unit. �
"EER" and "COP" is the coefficient of performance [= capacity (kW) input power (kW)]. �
EER and COP values are base on our own testing method. �
Current model
Cooling Heating
V-II Series
EEREER3.0 3.50.0 4.0
Cooling EER27% increase!
3.2
3.894.07
3.0 3.50.0 4.0 COPCOP
Heating COP18% increase!
3.7
4.37
AIR INTAKE
Sine wave DC inverter control
Front intake port (omnidirectional intake)
DC twin rotary compressor
Capacity 5%increase
Powerful large propeller fan
DC fan motor
Subcool heat exchanger
Heat exchanger
Use of sine wave DC inverter control allows high efficiency and energy saving.
High performance DC twin rotary compressor maximizes efficiency from low speed to high speed operation.
Front intake port is designed to prevent decreasing airflow when multiple outdoor units are installed.
A newly designed by CFD analysis fan achieves high performance and low noise operation.
Heat exchanger efficiency is increased up to approx.100% by use of heat exchanger tube with high heat transfer dual coil.
High performance and high efficiency compact DC fan motor.
Capacity is increased 5% due to new unique design.
- (01-01) -
GEN
ERA
LIN
FOR
MAT
ION
GEN
ERA
LIN
FOR
MAT
ION
ENERGY EFFICIENCY COMBINATION �
ECONOMY OPERATION �
Economy operation can be set by remote controller.The temperature setting is offset automatically over a certain period of time.
ROOM TEMPERATURE SET �POINT LIMITATION
The minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants.
PEAK CUT OPERATION �
Operation capacity can be set in 4 steps for rated capability.The power consumption at peak is cut down and the maximum load is suppressed.
AUTO-OFF TIMER �Each remote controller is equipped with an OFF timer function that automatically stops operation when a fixed time has elapsed from the start of operation. This prevents wasteful operation. (NB Except simple remote controller)
[For 16HP]
18%energy saving !
12%energy saving !
10%energy saving !
[For 24HP]
12HP 12HP
[For 28HP]
12HP16HP
16HP 8HP 8HP
8HP 8HP 8HP
12HP 8HP 8HP
[Space saving combination] [Energy efficiency combination]
Cooling Set Temperature
Economy operationControl Temperature
Heating Set Temperature
Economy operationControl Temperature
Set Temp.
MAX. -4°C
MAX. +2°C
Economy operation
UpUp
Economy operation
Set Temp.Down
DownDown
Down
Heating set temp. range
Cooling set temp. range
Heating Cooling
Original Settemp. limitation
Set pointlimitation setting
°C3028262422201816141210
Operation setting (System Controller)
W
Capacity
Time
Setting level
Peak cut
Controldevice
Signal input
(Comparison of average COP)
- (01-02) -
GEN
ERA
LIN
FOR
MAT
ION
GEN
ERA
LIN
FOR
MAT
ION
HIGH DESIGN FREEDOM1-1-2.OVERALL PIPING LENGTH �1,000m
World’s top class overall piping length of 1,000m allows for application in a wide variety buildings.
HIGH STATIC PRESSURE OF �80Pa
The outdoor unit can have a condenser hood easily connected with a static pressure of 80Pa standard. This allows outdoor units to be installed within plant rooms in high rise buildings.
1,000m max.
Total pipe length
Actual pipe length150m max.
For the outdoor unit stated below : 40m max.
Height difference between outdoor and indoor units 50m max.
Pipe length from first separation tube to the farthest indoor unit60m max.
Height difference between indoor and indoor units 15m max.
Installation scene
Large diameter fan and DC motor has been utilized allowing an external static pressure of 80Pa. This is approximately 2.6 times greater than the previous model.
Powerful discharge with an external static pressure of 80Pa.
80Paas standardPrevious model V-II Series
- (01-03) -
GEN
ERA
LIN
FOR
MAT
ION
GEN
ERA
LIN
FOR
MAT
ION
SPACE SAVING AND COMPACT SIZE �
Compact size has been achieved by significantly reducing the width of the outdoor units compared to previous models.
WIDE OPERATING RANGE �
Installation in extreme temperature conditions is possible due to an increase in operational range.Cooling : -15°C~46°CHeating : -20°C~21°C
*1 Note : When a multiple outdoor unit connection is used, operating range is from -5°C to 46°C in cooling.
VARIOUS COMBINATIONS �
Various combination from 8HP to 48HP with 2HP increments. 12 types, 55 models of indoor units can be selected ranging from 2.2kW to 25kW in capacity. A maximum of 150% indoor unit connectable capacity.
Note : when indoor unit connected capacity is greater than 100%, individual indoor units will operate at a slightly lower capacity when maximum capacity is required.
1,2401,300 2,600930
28%reduction
52%reduction
38.0m2
16.2m2
57%space saving
Previous model 10HP
16HP(8HPx2) ×10=160HP
16HP×10=160HP
Previous model
For 160HP
Previous model 16HP (8HP x 2)V-II Series 10HP
V-II Series
V-II Series 16HP
CoolingCooling46°C
21°C
-15°C -15°C -20°C -20°C
Heating
(°C)
-15°C areaOperationpossible
in cooling.
-20°C areaOperationpossible
in heating.
°C
°C°°C C
C
C CC
50
40
30
20
10
0
-10
-20
*1
Connectable indoor unit number
up to 48Wide variation of indoor units
12types, 55models
Connectable indoor unit capacity
Ratio up to 150%
- (01-04) -
GEN
ERA
LIN
FOR
MAT
ION
GEN
ERA
LIN
FOR
MAT
ION
HIGH RELIABILITY1-1-3.OUTDOOR UNIT OPERATION ROTATION �The compressor starting order is rotated so that the running time is shared.
BACKUP OPERATION �If one of two compressors malfunctions, it will not affect the operation of the remaining outdoor units.
Failure
If one of compressor fails, backup operation will be performed by the remaining compressors as emergency.*1
*1 Note: Backup operation may not be possible depending on the combination and trouble state.
Each indoor unit is controlled individually on the system network. This allows all indoor units to continue to operate unaffected even if an error should occur at any indoor unit’s on the VRF system.
Indoor unit continuous operation
Outdoor units
Indoor units
DC1
AC4
DC2
AAACCC55
DDDDCCCCCCCCCDDDDD33333333
DDDCCC111
AC4
DC2
AAACCC55
DC3
DC1
AC4
DDDDCCC22
AAACCC55
DC3
Rotation
Note : The inverter compressors start in priority. Operating rotation is alternated by the start / stop timing of the compressors
Rotation
Rotation
- (01-05) -
GEN
ERA
LIN
FOR
MAT
ION
GEN
ERA
LIN
FOR
MAT
ION
ADOPTION OF BLUE FIN HEAT EXCHANGER �
Corrosion resistant of the heat exchanger has been improved by the introduction of blue fin treatment to the outdoor unit’s heat exchanger.
REMOTE MONITORING �
The Web Monitoring system allows you view system operation at all times over the internet ensuring trouble free operation.
Blue fin heat exchanger
Standard chromate protection
Cobalt Blue protection
Aluminium base material
Hydrophilic coating
VRF System SideMonitoring Side
Internetor
Public Telephone Line
Outdoor unit
Indoor unit
Transmission line
Web Monitoring Tool
USB adaptor (Field supplied)
The operating VRF system in the building can be monitored in real time over the Internet.
- (01-06) -
GEN
ERA
LIN
FOR
MAT
ION
GEN
ERA
LIN
FOR
MAT
ION
EASY INSTALLATION1-1-4.EASILY TRANSPORTED �
SIMPLE SIGNAL LINE CONNECTION �Installation is made easier as the communications wiring can be connected continuously to any component.
Easy piping connection �The need for a oil equalization pipe as required on the previous model has been removed. The installation costs have been reduced by employing a Simple 2 pipe connection.
20% weight reduction(Than Previous model)
Note : In the case of 14HP
Design of outdoor unit allows for lifting straps to be used
Light weight Can be transported in a small elevator
Transporting by forklift
Easily craned into position using lifting belt hooks
Transport with forklift is possible.
Up to maximum length 3,600m
Other wiring method Simple wiring methodNote: In a multiple refrigerant system installation, Automatic addressing sequence cannot be initiated
Eliminating oil equalization pipe
- (01-07) -
GEN
ERA
LIN
FOR
MAT
ION
GEN
ERA
LIN
FOR
MAT
ION
AUTOMATIC ADDRESS SETTING �The address of each indoor unit can be automatically set by button swich of outdoor unit.
EASY ACCESS �By adopting a L-Shape front panel that can be removed, the work space for installation and service has been significantly expanded by this corner cutting structure. For multiple installations, work is performed easily and efficiently even in a narrow space.
FOUR WAY PIPING CONNECTION �Piping and wiring are available to the front, left and right, and bottom.
3 8 1 0
2 4 5 6
Automatic address setting is performed at outdoor unit
Addresses are automatically distributed from outdoor unit.
Press the pushbutton switch of outdoor unit.
Manual address setting from indoor unit and remote controller is also possible.
Expansion of work space
Four way connection
- (01-08) -
GEN
ERA
LIN
FOR
MAT
ION
GEN
ERA
LIN
FOR
MAT
ION
MORE COMFORT & CONVENIENCE1-1-5.LOW NOISE MODE �Two low noise modes can be selected automatically by quiet priority setting and capacity priority setting depending on the usage environment and outside temperature load.
SELECTABLE AUTO CHANGEOVER FUNCTION �Auto changeover setting allows for the product to easily switch between Cooling and heating modes regardless of the operation mode of other indoor units. This can be done via specific indoor unit with wired remote controller. This ensures comfortable operation all year round.
Switching to cooling and heating mode by specific remote controller in the main room, etc.
LOW NOISE DESIGN �Compressor noise has been significantly reduced by shielding the compressor compartment.
INDOOR UNIT �Low noise indoor unit lineup
100%
58dB
0
0
Heat load
100%
58dB
0
0
Heat loadHeat load
Air conditioning load factor
Quiet priority low noise mode
Quiet priority setting
Capacity priority low noise mode
Capacity priority setting
Reset automatically
Alternated automatically
Operating sound
CapacityDown
(time) (time)
Compressor compartment
Compact Duct Compact Cassette
Low Static Pressure Duct Compact Wall Mounted
- (01-09) -
GEN
ERA
LIN
FOR
MAT
ION
GEN
ERA
LIN
FOR
MAT
ION
PRECISION REFRIGERANT FLOW �CONTROLPrecision and Smooth refrigerant flow control is achieved by using a DC Inverter control in conjunction with individual indoor unit electronic expansion valve control. This allows for a high precision comfortable temperature control of ±0.5°C.
INDIVIDUAL AIR �CONDITIONING CONTROLThe desired temperature conditions of each room are met due to the Individual thermostat control of each indoor unit.
SIMPLE CENTRAL MANAGEMENT FUNCTION �
NON-STOP OIL RECOVERY OPERATION �A comfortable room condition is maintained during oil recovery mode because the product continues to operate without stopping the cooling or heating operation.
Set temp.
ColdColdCold
HotHot ±0.5
Room A24°C
Room C27°C
Room DOFF
Room E23°C
Room B18°C
Thermal change of the room *Simulation in heating operation.
Comfortable operation is achieved due to a small variation of room temperature
Reach the set temperature quickly
Previous model (Heating operation)
Operation stopped at oil recovery
On On
Time TimeOff
Non-stop oil recovery operation
High
Low
···················
···················
··········
Simple central control operation
Simple operation by icon display and color touch screen
Daily starting & stopping and temperature setting are managed.
The clock of each individual controller is periodically corrected.
Yearly schedule function
7.5 inch large LCD Touch Panel Controller
Clock setting function
Schedule screen
- (01-10) -
GEN
ERA
LIN
FOR
MAT
ION
GEN
ERA
LIN
FOR
MAT
ION
EASY SERVICE & MAINTENANCE1-1-6.DESIGN FOR EASY SERVICE AND MAINTENANCE �
ERROR STATUS CAN BE CHECKED EASILY VIA THE INDOOR �UNIT WIRED CONTROLLER
Consolidated electrical components make maintenance easy
Maintenance of electrical components, valves, and compressor parts from the front is possible.
Movable PCB panel that allows for easier maintenance work behind the PCB
Split front panel allows for maintenance from top or bottom of the outdoor unit
Easy-to-read 7-segment LED display which explains operational and trouble status
SU MO TU WE TH FR SA
An error code is displayed on a liquid crystal screen.
Wired remote controller Simple remote controllerFaulty unit number (Remote controller address)
Faulty unit number (Remote controller address)
Error code Error code
- (01-11) -
GEN
ERA
LIN
FOR
MAT
ION
GEN
ERA
LIN
FOR
MAT
ION
EMERGENCY STOP �Emergency alarm can be received by indoor, outdoor units or Touch Panel Controller when they received it, all units will be stopped.
NON-STOP OPERATION �When servicing a specific indoor unit, maintenance can be performed even without turning off the other indoor units.
TROUBLE DIAGNOSIS BY SERVICE TOOL �Suitable maintenance is possible by analysis of the operation data. Connection anywhere in the VRF network is easy.
Touch Panel Controller
Emergency stop function Emergency stop function
Emergency stop function
Note : In case of received Emergency alarm by Indoor/outdoor unit: All units connected within same refrigerant system will be stopped. Touch Panel Controller: all unit connected within VRF network system with Touch Panel Controller will be stopped.
Outdoor unit
Software
Transmission line
USB adaptor (Field supplied)
Service Tool
Indoor unit
Easy to carry out with USB adaptor
On On On On OnUndergoingmaintenance
- (01-12) -
GEN
ERA
LIN
FOR
MAT
ION
GEN
ERA
LIN
FOR
MAT
ION
MODEL LINE UP1-2.OUTDOOR UNIT1-2-1.
Extensive line up from 8HP to 48HP in 2HP increments. ●Space saving combination and Energy efficiency combination available, which can be ●selected to suit any air conditioning needs.
LINE UP (SINGLE) �
SPACE SAVING COMBINATION �Combinations other than the followings are prohibited. ●
HP Capacity(kW) Model name Chassis
8 22.4 AJ�A72LALH
10 28.0 AJ�A90LALH
12 33.5 AJ�108LALH
14 40.0 AJ�126LALH
16 45.0 AJ�144LALH
HP Capacity(kW) Set model name Unit1
(Model name)Unit2
(Model name)Unit3
(Model name)Maximum
connectable indoor unit
8 22.4 AJ�A72LALH AJ�A72LALH - - 1510 28.0 AJ�A90LALH AJ�A90LALH - - 1612 33.5 AJ�108LALH AJ�108LALH - - 1714 40.0 AJ�126LALH AJ�126LALH - - 2116 45.0 AJ�144LALH AJ�144LALH - - 2418 50.4 AJ�162LALH AJ�A90LALH AJ�A72LALH - 3220 55.9 AJ�180LALH AJ�108LALH AJ�A72LALH - 3222 61.5 AJ�198LALH AJ�108LALH AJ�A90LALH - 3224 67.0 AJ�216LALH AJ�108LALH AJ�108LALH - 3526 73.5 AJ�234LALH AJ�126LALH AJ�108LALH - 3928 78.5 AJ�252LALH AJ�144LALH AJ�108LALH - 4230 85.0 AJ�270LALH AJ�144LALH AJ�126LALH - 4532 90.0 AJ�288LALH AJ�144LALH AJ�144LALH - 4834 95.0 AJ�306LALH AJ�108LALH AJ�108LALH AJ�A90LALH 4836 100.5 AJ�324LALH AJ�108LALH AJ�108LALH AJ�108LALH 4838 107.0 AJ�342LALH AJ�126LALH AJ�108LALH AJ�108LALH 4840 112.0 AJ�360LALH AJ�144LALH AJ�108LALH AJ�108LALH 4842 118.5 AJ�378LALH AJ�144LALH AJ�126LALH AJ�108LALH 4844 123.5 AJ�396LALH AJ�144LALH AJ�144LALH AJ�108LALH 4846 130.0 AJ�414LALH AJ�144LALH AJ�144LALH AJ�126LALH 4848 135.0 AJ�432LALH AJ�144LALH AJ�144LALH AJ�144LALH 48
- (01-13) -
GEN
ERA
LIN
FOR
MAT
ION
GEN
ERA
LIN
FOR
MAT
ION
ENERGY EFFICIENCY COMBINATION �Combinations other than the followings are prohibited. ●
MODEL DESIGNATION �
HP Capacity(kW) Set model name Unit1
(Model name)Unit2
(Model name)Unit3
(Model name)Maximum
connectable indoor unit
16 44.8 AJ�144LALHH AJ�A72LALH AJ�A72LALH - 3022 62.4 AJ�198LALHH AJ�126LALH AJ�A72LALH - 3324 67.2 AJ�216LALHH AJ�A72LALH AJ�A72LALH AJ�A72LALH 3626 72.8 AJ�234LALHH AJ�A90LALH AJ�A72LALH AJ�A72LALH 3928 78.3 AJ�252LALHH AJ�108LALH AJ�A72LALH AJ�A72LALH 4230 84.8 AJ�270LALHH AJ�126LALH AJ�A72LALH AJ�A72LALH 4532 89.4 AJ�288LALHH AJ�108LALH AJ�108LALH AJ�A72LALH 4834 95.9 AJ�306LALHH AJ�126LALH AJ�108LALH AJ�A72LALH 4836 102.4 AJ�324LALHH AJ�126LALH AJ�126LALH AJ�A72LALH 4840 113.5 AJ�360LALHH AJ�126LALH AJ�126LALH AJ�108LALH 4842 120.0 AJ�378LALHH AJ�126LALH AJ�126LALH AJ�126LALH 4844 125.0 AJ�396LALHH AJ�144LALH AJ�126LALH AJ�126LALH 48
A J Y A 9 0 L A L H1 2 3 4 5 6 7 8 9 10 11
TypeAJ : Outdoor unit
DestinationH: GENERALY: FUJITSU
FunctionL : Inverter (R410A)
Series nameH : V II
Set nameH : Energy Efficiency CombinationBlank : Space Saving Combination
Model code (kW)A72 : (22.4)A90 : (28.0)108 : (33.5)126 : (40.0)144 : (45.0)
Model change codeAL
- (01-14) -
GEN
ERA
LIN
FOR
MAT
ION
GEN
ERA
LIN
FOR
MAT
ION
INDOOR UNIT1-2-2.LINE UP (1/2) �
Various combinations of types and capacity 12 types 55 models, ranging from 2.2kW to 25.0kW.
Capacity CompactCassette Cassette Compact
Duct Slim DuctLow StaticPressure
DuctDuct
kW Modelcode
2.2 072.8 093.6 124.5 145.6 187.1 249.0 3011.2 3612.5 4514.0 5418.0 6022.4 7225.0 90
Compact Cassette Cassette Compact DuctAUXB07LALHAUXB09LALHAUXB12LALHAUXB14LALHAUXB18LALHAUXB24LALH
AUXD18LALHAUXD24LALHAUXA30LALHAUXA36LALHAUXA45LALHAUXA54LALH
ARXB07LALHARXB09LALH
ARXB12LALHARXB14LALHARXB18LALH
Slim Duct Low Static Pressure Duct DuctARXD07LATHARXD09LATHARXD12LATHARXD14LATH
ARXD18LATH
ARXD24LATH
ARXB24LATHARXB30LATHARXB36LATHARXB45LATH
ARXA24LATHARXA30LATHARXA36LATHARXA45LATH
- (01-15) -
GEN
ERA
LIN
FOR
MAT
ION
GEN
ERA
LIN
FOR
MAT
ION
LINE UP (2/2) �
Various combinations of types and capacity 12 types 55 models, ranging from 2.2kW to 25.0kW.
Capacity High StaticPressure
DuctFloor / Ceiling Ceiling
CompactWall Mounted(EEV internal)
CompactWall Mounted
(EEV external)Wall Mounted
kW Modelcode
2.2 072.8 093.6 124.5 145.6 187.1 249.0 3011.2 3612.5 4514.0 5418.0 6022.4 7225.0 90
High Static Pressure Duct Floor / Ceiling CeilingARXC36LATHARXC45LATHARXC60LATH
ARXC72LATHARXC90LATH
AB�A12LBTHAB�A14LBTHAB�A18LBTHAB�A24LBTH
AB�A30LBTHAB�A36LBTHAB�A45LBTHAB�A54LBTH
Compact Wall Mounted(EEV internal)
Compact Wall Mounted(EEV external)
Wall Mounted
AS�A07LACHAS�A09LACHAS�A12LACHAS�A14LACH
AS�E07LACHAS�E09LACHAS�E12LACHAS�E14LACH
AS�A18LACHAS�A24LACHAS�A30LACH
MODEL DESIGNATION �
A U X B 1 2 L A L H1 2 3 4 5 6 7 8 9 10
TypeAU: CassetteAR: DuctAB: Floor/Ceiling or CeilingAS: Wall Mounted
DestinationH: GENERALY: FUJITSUX:Neutral brand
ModelA: StandardB: Compact (AU)B: Low Static Pressure (AR)C: High Static Pressure (AR)D: Slim (AU) (AR)E: EEV external (AS)
FunctionL : Inverter (R410A)
Series nameH : V II
Model code (kW)07 (2.2)09 (2.8)12 (3.6)14 (4.5)18 (5.6)24 (7.1)30 (9.0)36 (11.2)45 (12.5)54 (14.0)60 (18.0)72 (22.4)90 (25.0)
Model change codeACALATBT
EV kit
- (01-16) -
GEN
ERA
LIN
FOR
MAT
ION
GEN
ERA
LIN
FOR
MAT
ION
CONTROLLER1-2-3.LINE UP �
CENTRAL CONTROL �
INDIVIDUAL CONTROL �
MODEL DESIGNATION �
Type Model
System Controller UTY-APGXTouch Panel Controller UTY-DTG�Central Remote Controller UTY-DCG�Group Remote Controller UTY-CGG�Wired Remote Controller UTY-RNK�Simple Remote Controller (With operation mode) UTY-RSK�Simple Remote Controller (Without operation mode) UTY-RHK�Wireless Remote Controller UTY-LNH�
System Controller Touch Panel Controller
Central Remote Controller Group Remote Controller
Wired Remote Controller Simple Remote Controller Wireless Remote Controller
U T Y - R N K Y T1 2 3 4 5 6 7 8 9
TypeAPG: System ControllerDTG: Touch Panel ControllerDCG: Central Remote ControllerCGG: Group Remote ControllerRNK: Wired Remote ControllerRSK: Simple Remote Controller (with operation mode)RHK: Simple Remote Controller (without operation mode)LNH: Wireless Remote Controller
DestinationG: GENERALY: FUJITSUYT: FUJITSU (Australian standard)X:Neutral brand
Series nameUTY : Control unit
UTY-APGX UTY-DTG�
UTY-RNK� UTY-LNH�UTY-RSK� UTY-RHK�
UTY-CGG�Network Convertor (UTY-VGGXZ1) is necessary to connect Group Remote Controller to VRF network system.
SET TEMP. START/STOP
(With operation mode) (Without operation mode)
UTY-DCG�
- (01-17) -
GEN
ERA
LIN
FOR
MAT
ION
GEN
ERA
LIN
FOR
MAT
ION
ADAPTOR / CONVERTOR / MAINTENANCE1-2-4.
Network ConvertorModel : UTY-VGGXZ1
Split type systems can be controlled from a centralcontroller via the convertor.
Group remote controller can be controlled up to 96 indoor unitsvia the convertor.
Network Convertor for LONWORKS®
Model : UTY-VLGXFor connection between VRF network system and a LONWORKS® open network for management of small to medium-sized BMS.
Signal AmplifierModel : UTY-VSGX
If the total length of transmission line exceeds 500m, or the number of units exceeds 64, Signal Amplifier will be necessary to use.
Web Monitoring ToolModel : UTY-AMGX
Trouble free operation at all times by web monitoring system.The operation status of the VRFnetwork system within the building can be monitored in real time over the Internet.
Service ToolModel : UTY-ASGX
Extensive monitoring and analysis functions for installation and maintenance. Operation status and error history can be grasped promptly and adequately.
BACnet® GatewayModel : UTY-ABGX
The central control ofmaximum 1600 indoor unitscan be realized by connectingthe VRF network system tothe BACnet®, a global standardof the open network.
External Switch ControllerModel : UTY-TEKX
Air conditioner switchingcan be controlled byconnecting other externalsensor switches.
- (01-18) -
GEN
ERA
LIN
FOR
MAT
ION
GEN
ERA
LIN
FOR
MAT
ION
OUTDOOR UNIT BRANCH KIT1-2-5.Outdoor Unit Branch Kit Model :UTR-CP567X
Liquid Pipe Gas Pipe
Outdoor Unit Branch KitModel :UTP-CX567A
Liquid Pipe Gas Pipe
SEPARATION TUBE1-2-6.Separation Tube Model :UTR-BP567X
Liquid Pipe Gas Pipe
Separation TubeModel :UTP-AX567A
Liquid Pipe Gas Pipe
- (01-19) -
GEN
ERA
LIN
FOR
MAT
ION
GEN
ERA
LIN
FOR
MAT
ION
Separation Tube Model :UTR-BP090X
Liquid Pipe
Gas Pipe
Separation Tube Model :UTR-BP180X
Liquid Pipe
Gas Pipe
Separation TubeModel :UTP-AX090A
Liquid Pipe
Gas Pipe
Separation TubeModel :UTP-AX180A
Liquid Pipe
Gas Pipe
HEADER1-2-7.Header
Model : UTR-H0906L Model : UTR-H1806L Model : UTR-H0908L Model : UTR-H1808LLiquid Pipe Liquid Pipe Liquid Pipe Liquid Pipe
Gas Pipe Gas Pipe Gas Pipe Gas Pipe
- (01-20) -
GEN
ERA
LIN
FOR
MAT
ION
GEN
ERA
LIN
FOR
MAT
ION
EV KIT1-2-8.
EV Kit Models : UTR-EV09XB UTR-EV14XB
For Compact Wall Mounted type (EEV external type)
CASSETTE GRILLE1-2-9.
Cassette grille Models : UTG-UFYC-W UTG-UFGC-W
Cassette grille Models : UTG-UGYA-W UTG-UGGA-W
For Compact Cassette type For Cassette type
- (01-21) -
GEN
ERA
LIN
FOR
MAT
ION
GEN
ERA
LIN
FOR
MAT
ION
OTHERS (optional parts)1-2-10.
Flange (Square)Model : UTD-SF045T
Flange (Round)Model : UTD-RF204
For Low Static Pressure Duct / Duct type205 x 1,063 ; L=40 (mm)
For Low Static Pressure Duct / Duct / Ceiling typeø195 (ø205) ; L=85 (mm)
Long-life FilterModel : UTD-LF25NA
Long-life FilterModel : UTD-LF60KA
For Low Static Pressure Duct / Duct type For High Static Pressure Duct type
x 2 pcs x 2 pcs
For ARXC36For ARXC45For ARXC60
Drain Pump Unit Models : UTZ-PX1BBA *1 UTZ-PX1NBA *2
Drain Pump Unit Model : UTR-DPB24T
*1 For Compact Duct type*2 For Low Static Pressure Duct type / Duct type For Ceiling type
Air outlet shutter plate Models : UTR-YDZC
Air outlet shutter plate Models : UTR-YDZB
For Cassette typeFor Compact Cassette type
- (01-22) -
GEN
ERA
LIN
FOR
MAT
ION
GEN
ERA
LIN
FOR
MAT
ION
Panel spacerModel : UTG-BGYA-W
Wide panelModel : UTG-AGYA-W
242m
m
Panel spacerPanel 600mm
Panel 600mm
Indoor unit 950mm
IR Receiver Unit Models: UTB-YWB, UTB-TWB *1 Models: UTB-YWC, UTB-TWC *2
IR Receiver Unit Models : UTY-LRHYB1UTY-LRHGB1
*1: For all Duct type (Except for Slim Duct)*2: For all Duct type For Cassette type
Remote Sensor Unit Model : UTD-RS100
Thermo-sensor for sensing thetemperature of arbitrary placein the room
Fresh air intake kit Model : UTZ-VXGA
For Cassette type
Fresh air intake kit Model : UTZ-VXAA
For Compact Cassette type
Insulation Kit for High Humidity Models : UTZ-KXGA *1
UTZ-KXGB *2 UTZ-KXGC *3
Insulation Kit
*1 For Cassette type*2 For Slim Cassette type*3 For Compact Cassette type
Auto louver grille kit Models : UTD-GXSA-W *1 UTD-GXSB-W *2 UTD-GXSC-W *3
*1 For Slim Duct (07-14 models)*2 For Slim Duct (18 model)*3 For Slim Duct (24 model)
- (01-23) -
GEN
ERA
LIN
FOR
MAT
ION
GEN
ERA
LIN
FOR
MAT
ION
REVISION CODE1-3.ABOUT REVISION CODE �The following functions are different according to Revision code.
Revision code RemarksNone or A B / C
Out
door
uni
t
Energy-saving level Level 5 (Limited at 100%) � ○Back up operation � ○Electricity meter installation � ○ Electricity meter can be set up in Terminal CN135.
Energy saving software UTY-PEGX � ○
Indo
or u
nit Forced stop function �*1 ○
Energy saving software UTY-PEGX � ○Setting of Auto louver grille kit (option) �*2 ○ For Slim duct type only
*1: ARXD07, 09, 12, 14, 18, 24LATH (Slim Duct), AB*A12, 14, 18, 24LBTH (Floor/Ceiling), AB*A30, 36, 45, 54LBTH(Ceiling), AS*A18, 24, 30LACH (Wall Mounted) are available regardless of revision code.
*2: Auto louver grille kit doesn’t operate correctly when setting it to indoor unit other than Revision code B.
METHOD OF DISTINGUISHING REVISION CODE �Outdoor unit �
Rating LabelSerial No. Revision Code: None or A; X0XXXXX
B; X2XXXXX C; X3XXXXX
Revision code
Carton Label
Revision code
Indoor unit �
Rating Label
Revision code
Carton LabelRevision code
- (01-24) -