Top Banner
1 E895 - correlation analysis - Status Report Mike Lisa, The Ohio State University • E895 Motivation and Measurement • Status of HBT analysis • Summary and plans
32

1 E895 - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

Jan 29, 2016

Download

Documents

Amie Thomas
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

1

E895 - correlation analysis - Status ReportMike Lisa, The Ohio State University

• E895 Motivation and Measurement

• Status of HBT analysis

• Summary and plans

Page 2: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

2

Lawrence Berkeley Lab D. Best, T. Case, K. Crowe, D. Olson, G. Rai, H.-G. Ritter, L. Schroeder, J. Symons, T. Wienold

Brookhaven National Lab S. Gushue, N. Stone

Carnegie Mellon University M. Kaplan, Z. Milosevich, J. Whitfield

Columbia University I. Chemakin, B. Cole, H. Hiejima, X. Yang, Y. Zhang

U.C. Davis P. Brady, B. Caskey, D. Cebra, J. Chance, J. Draper, M. Heffner, J. Romero, L. Wood

St. Mary’s College J. Kintner

Harbin Institute (China) L. Huo, Y. Liu, W. Zhang

Kent State Univeristy M. Justice, D. Keane, H. Liu, S. Panitkin, S. Wang, R. Witt

Lawrence Livermore Lab V. Cianciolo, R. Sotlz

Ohio State University A. Das, M. Lisa, R. Wells

University of Auckland (NZ) D. Krofcheck

Purdue University M. Gilkes, A. Hirsch, E. Hjort, N. Porile, R. Scharenberg, B. Srivastava

S.U.N.Y. Stony Brook N.N. Ajitanand, J. Alexander, P. Chung, R. Lacey, J. Lauret, E. LeBras, B. McGrath, C. Pinkenburg

Page 3: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

3

Systematics/meta-analysis suggest approach to maximum AGS energy interesting...

P. Braun-Munzinger and J. Stachel,NPA606, 320 (1996)

Page 4: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

4

Perhaps some signals only apparent near threshold

D. Rischke, NPA 610, c88 (1996)

E895 flow statusdiscussed by R. Lacey

Page 5: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

5

Ideally, HBT gives a measure of source size

C k kP k k

P k P k

d x d x x x e

d x d x x x

Q

i k k x x

2 1 21 2

1 2

31

32 1 23

13

2 1 2

2

1

1

2 1 2 1

( , )( , )

( ) ( )

( ) ( )

( ) ( )

~( )

( ) ( )

r rr r

r r

r r

r r

r

r r r r

=⋅

= ± ⋅ ⋅ ⋅∫ ⋅⋅ ⋅ ⋅∫

= ±

⋅ − ⋅ −ρ ρρ ρ

ρ

PionSource ρ( )x

C (Qinv)

Qinv (GeV/c)

1

2

0.05 0.10

Width ~ 1/R

Page 6: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

6

HBT systematics at AGS interesting in themselves,

& can look for suprises

“”“c”

Rischke & GyulassyNPA 608, 479 (1996)

May miss signal at “too high” Ebeam

Page 7: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

7

HBT - another handle onmean field effects at AGS

Generated by H. Liu and S. Panitkin

Page 8: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

8

AGS BevalacParticle reconstruction upgrades have taken huge effort,but have born fruit...

Page 9: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

9

PID via dE/dxfor primaries

(negative particles cleaner)

2 AGeV

4 AGeV

8 AGeV

Page 10: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

10

Strange neutrals reconstructed(& provide sensitive diagnostic of data quality)

plots from P. Chung, SUNY-SB

p + K0

Page 11: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

11

Non-uniform trigger in dataset analysedWill be possible toselect top ~5% forall energies offline

Current analysis:2 GeV: b 0-8 fm4 GeV: b 0-8 fm8 GeV: b 0-3 fm

Otherwise seems OKe.g. log increase ofmultiplicity with Ebeam:Ebeam Ebeam

Mmax Mmax + 50M

max Mmax + 15

Page 12: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

12

Singles coverage for pions

Page 13: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

13

Large acceptance many -

But...phase space meansmost are at large Q

Background (denominator)generated with standardevent-mixing (15 previous)

4 GeV central

Page 14: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

14

Pairwise cuts to remove track splitting effects“Raw” correlation functionshows encouraging structureat low Qinv

Simulations: requirement that> 50% of track is seenkills truly found pairs.

(Au+Be event)

Page 15: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

15

Pairwise cuts, cont’Track-splitting virtually eliminated by pairwise cut:

require that sum of % track seen > 100% (applied to “real” and “mixed” pairs)

Next low-Q problem:track-merging.

Page 16: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

16

Merging effect reduced by cut on projected seperation at exit of TPC.

Real pairs

Mixed pairs

Page 17: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

17

Require particles to exit TPC 10 cm apart.

0 cm cut

5 cm cut

10 cm cut

15 cm cut

Page 18: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

18

Overview of E895 HBT AnalysisOverview of E895 HBT Analysis

raw data

(pass1)

TRKS

HBT_SWHBT_EVENT_CUTHBT_TRK_CUTHBT_PAIR_CUT

• Embed MC pairs into raw data• perform pass1• correlate embedded, extracted particles

fit of singles distribution

generation of MC pairs(kuip macro files)

EMBED_PARTSTRKS

AM_PID AM_HBT

histogramsacceptance correctionscoulomb correctiondiagnostic ntuplescorrelation functions

Page 19: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

19

Corrections - I

Ideally... C k kP k k

P k P kP k k

P k ktrue

mixed2 1 2

1 2

1 2

1 2

1 2

( , )( , )

( ) ( )( , )( , )

r rr r

r rr rr r=

⋅=

“Background” pair distribution contains all physicsand detector effects except for the BE symmetrization

Well-known deviation from this is due to final-state Coulomb repulsion...

Approximate correction - Gamow factor:

G Qe

m e

Qinvinv

( ) ;=−

=1

η ηη

h

(Better to do full Coulomb integration)

Page 20: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

20

Corrections - IIDetector acceptance effects are more subtle, especially with a tracking detector

Original pion pair

k1

k2

MC Scattering

Pattern recognition

Digitization, thresholds

Pixel noise

Measuredparticle(s)

k1’, k2

’, (k3’...)

Track merging and splitting and momentum resolution and distortion.

Hit the low-Q pairs hardest, and affect the correlation signal significantly.

Effects depend on k1, k2 (six-dimensional!), as well as track and pair cuts!!!

Correcting for or minimizing these 2-particle effects requires detailed simulation.

Page 21: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

21

Generating the Acceptance /Resolution Correction - I

C2(ideal)

C2(reconstructed)=

R(k1,k2)B(k1,k2)

R(k1,k2)B(k1,k2)

Kacceptance =

B(k1,k2) =d6N

d3k1d3k2

R(k1,k2) =d6N

d3k1d3k2

• C2(k1,k2)

for someset of cuts:

only phase space (k) cut applied(no track quality or 2-track cuts)

B(k1,k2) =d6N

d3k1d3k2

R(k1,k2) =d6N

d3k1d3k2

• C2(k1,k2)

apply same track and pair cuts as applied to data

(weighting by C2(k1,k2) implies foreknowledge of correlation function iterative approach)

Page 22: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

22

Understanding close pairs

•Close pairs are embedded into real data events at pixel levelwith measured momentum distribution, to get correct noisetrack density environment•Full event reconstruction run•Gives momentum distortions, pair loss...

Page 23: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

23

Resolution from the 4 GeV simulations...

10 MeV/c resolution(includes MCS)

finite resolution + phase spacegive Q distortion at low Q

(Qin > 40 MeV/c)

Page 24: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

24

Pair loss from 4 GeV simulations

Pair loss constant above 50 MeV/c(statistical loss of single track)

Single pair in...

Lost pair Split track

Page 25: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

25

Finally: “Correction to the Coulomb Correction”

In the measured ratios, we apply the Coulomb correction (currently the Gamowcorrection) according to the measured Q, not the true Q.

With the simulated pairs, we have the true and reconstructed momenta, socan account for this.

Then, the full acceptance/resolution correction function is:

R(k1,k2)B(k1,k2)

R(k1,k2)B(k1,k2)

G(k1,k2)

G(k1,k2)

Page 26: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

26

Corrections for 10 cm exit seperation

Page 27: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

27

Corrections for 2 cm exit separation

Page 28: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

28

Acceptance/resolution well understood & accounted for

2 cm exit separation cut10 cm exit separation cut

Different cuts give very different raw correlation functions.But corrected correlation function is robust.

2 GeV results2 GeV results

Page 29: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

29

Data points consistent - fits are sensitive

Page 30: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

30

4 GeV results stable (and reasonable) as well

10 cm exit separation cut 2 cm exit separation cut

Page 31: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

31

8 GeV results not stable or reasonable(under study)

10 cm exit separation cut 2 cm exit separation cut

Page 32: 1 E895  - correlation analysis - Status Report Mike Lisa, The Ohio State University E895 Motivation and Measurement Status of HBT analysis Summary and.

32

SummarySummary• E895 can measure low-Q correlations well

• Difficulties of close pairs (splitters/mergers) largely addressed through pairwise cuts

• Detailed simulations generate corrections that track with cuts– These corrections are significant and important

• Different quality cuts very different measured correlation functions very different measured corrections NOT different corrected correlation functions

• Must figure out what is going on at high energy

• Multi-dimensional HBT and phase space cuts come next

(present analysis on < 5% of data)