1 An Update on the Evaluation of Personal Air Monitoring Data at the Savannah River Site T. R. La Bone D. J. Hadlock Westinghouse Savannah River Company Aiken, SC 29808
Dec 24, 2015
1
An Update on the Evaluation of Personal Air Monitoring Data at
the Savannah River SiteT. R. La BoneD. J. HadlockWestinghouse Savannah River CompanyAiken, SC 29808
2
Outline
Some history on the use of PAS at SRS Why we developed a PAS program now
The current PAS program at SRS Evaluation of the Calendar Year 2003 data
Concurrent evaluation other aspects of the program
Dose Assignment from PAS What happened After the Presentation
3
History of PAS Use at SRS
Prior to 2003 the use of PAS was not well received by RCO or Workers. Results were calculated in DAC (Pu-239)
Used MDC for determining DAC-hr exposure DAC-hrs for workers tracked manually (paper and
pencil) RCO only used PAS if someone held a gun to
their head
4
History of PAS Use at SRS In 2002 we ran a pilot study in FB-Line for
bioassay associated with highly insoluble Pu. Included PAS
Still not well received, however there was light at the end of the tunnel. Put a minimum PAS program into existence; some PAS
equipment purchased.
PAS results were calculated only in DAC-hr Volume of sample no longer an issue Detectability based on counting equipment and PAS flow
rate.
5
Calculating DAC-hr from PAS
K
hrDAC
SR
BR
ALI
dpmhrDAC
2000
Where: dpm = Activity on filter paper
ALI = Annual Limit of Intake in dpm
BR = Worker Breathing Rate
SR = Sampling Rate of the sampler
K = Collection efficiency/self absorption
6
The Light Becomes Brighter MDE is <2 DAC-hrs at 4 Lpm
Sufficient to determine if worker significantly exposed
Negates need to calculate DAC Used Pilot program to do a few jobs
Middle of nowhere; no power; large area; etc. Worked well
A few procedure revisions along with developing a DAC-hr tracking database maintained by the Central Counting Facility and we had a complete program.
7
Program Outline
Issue PAS to worker; up to six additional workers on one PAS.
In-Facility counting within 24-hrs to show <8 DAC-hrs, if not contact Internal Dosimetry.
Send to CCF and count after 120-hr decay. CCF results placed in tracking database.
Flags any person >8 DAC-hrs single sample or, Any person >40 DAC-hrs for CY. Report generated for all workers >4 DAC-hrs for CY.
8
Use of PAS by Facility41
8
273 32
3
94 65
15 35 11 13 5 1 2 2 2
1384
578
420
162
127
44 39 34 33 11 4 4 3 3
0
200
400
600
800
1000
1200
1400
16002
47
-F
21
1-1
4H
30
0-M
72
4-7
E
22
1-H
67
7-T
73
0-2
B
66
1-6
E
10
5-K
ET
F
29
9-H
OH
BL
22
1-F
FB
L
Nu
mb
er
Measurements
Assignments
2846 assignments1259 measurements
9
Reason PAS SelectedLocation PAS Used Because Reason
247-F No Power in Facility convenience
211-14H Study to justify PPE selection of no respirators
representative
300-M Little power in facility (D&D work) convenience
724-7E Outdoor work; little power convenience
221-H Large work area convenience
677-T No power in facility convenience
730-2B Outdoor work in remote areas convenience
661-6E Heavy equipment ops convenience
105-K Fuel Cutting - fume hood with no respirators
representative
10
SRS PAS Rules of Engagement An exposure of >8 DAC-hrs in one day will
trigger a special bioassay. An exposure of >40 DAC-hrs in a CY will
trigger a special bioassay. The special bioassay will be used to assign
dose unless the special bioassay cannot refute the exposure data.
In January, all cumulative exposures will be converted to dose using conservative DCFs.
11
SRS PAS Rules of Engagement Doses between 10 and 100 mrem will be
reported as calculated. For doses >100 mrem, special bioassay
samples will be requested and analyzed before the dose is assigned.
12
Analysis of 2003 Results10
944
2115
95 7 5 36 5
1 2 2 04
1 2 1 0 1 1 1 1 0 0 2 0 0 0 0 1 2 1 0 1 1 1 0 0 0 0 0 0 0 1
0
20
40
60
80
100
1201 4 7
10
13
16
19
22
25
28
31
34
37
40
43
46
Number of Times PAS Worn
Nu
mb
er
of
Wo
rke
rs
255 workers wore PAS1259 times
13
Probit Plot: 1259 Exposures Measured for 255 Workers
-1
0
1
2
3
4
5
6
7
8
9
1 2 3 4 5 6 7 8 9
Probits
Me
as
ure
d D
AC
-Ho
urs
14
Probit Plot: 2846 Exposures Assigned to 447 Workers
-1
0
1
2
3
4
5
6
7
8
9
1 2 3 4 5 6 7 8 9
Probits
As
sig
ne
d D
AC
-Ho
urs
15
Cumulative CEDE for the 447 Workers – exposures >10 mrem from U.
-5
0
5
10
15
20
25
30
35
40
45
50
2 3 4 5 6 7 8
Probits
CE
DE
(m
rem
)
16
Bottom Line Reviewed all workers with >4 DAC-hrs
cumulative exposure for CY 2003 Excluded the DAC-hr exposure for those events
where a special bioassay was performed (3 workers).
Assigned dose based on conservative dose conversion factors
Sixteen workers assigned a dose ranging from about 11 to 45 mrem. All assigned dose was from Uranium exposure
(assumed Class Y)
End of 7/14/04 AMUG Session Talk.
17
Then What Happened? Phone Call the Next Morning
Non-HP Management was ‘concerned’ about the impact to the workers of being exposed internally and disagreed with our programmatic approach.
The assignment of dose to the workers for CY03 was put on hold.
Radiological Protection management concurred with our approach; DOE-SR Radiological Protection also concurred. A few days of e-mails and face to face discussion.
18
So, What’s the Problem? Conference call with Managers on August 24
of 04. List of concerns: Summing PAS results (both + and -).
You must have an MDA; how can you see that small? 4 DAC-hr Action Level (10 mrem)
To low; can’t see that low of a dose. Why can’t we use in-vitro bioassay?
Our routine program must be deficient. Why are we required to assign this dose?
We didn’t do this at Rocky Flats!
19
So, What’s the Problem? List of concerns (Cont.):
Why don’t we assign dose from a CAM? You don’t use the “CAM in the corner”.
Other Concerns brought up in conversation: If I had known workers were being exposed, I
would have had RCO do something to stop it. No one told our workers they would get internal
dose assigned when wearing a PAS. This started the long process of meetings
with Senior Managers to come to a resolution.
20
Our Responses to Their Concerns Summing +/- PAS results
Explained the validity of this method Wrote white paper detailing our justification
Showed that use of a DL did not affect the end results.
End result was that we decided it was not worth fighting for (end result not changed). instituted calculating a DL for each PAS sample in the
database. Results <DL excluded from a worker’s total.
21
Our Responses to Their Concerns Output from a worker’s annual exposure:
22
Our Responses to Their Concerns 4 DAC-hr Action Level (10 mrem)
SRS uses a threshold of 10 mrem for reporting internal dose from a bioassay sample; applied to PAS to eliminate reporting insignificant doses.
Strict reading of the regulations would lead one to believe that any dose should be reported. The real question, if you wanted to ask it, is why not less
than 4? Management decided they wanted doses reported
quarterly. Okay with us.
23
Our Responses to Their Concerns Why can’t we use in-vitro bioassay?
Attempt made to say that if PAS could “see” the dose, then our bioassay program is deficient. Continuing problem of management/workers believing
that if their routine bioassay is negative, it means zero. Discussions on what a routine bioassay can or cannot
do for you. Have been trying to get this point across for years. Too
many energy units to absorb.
This concern was essentially dropped. Beating up your bioassay program is not a good career
path.
24
Our Responses to Their Concerns Why are we required to assign this dose?
SRS is using PAS as a bioassay in some cases (e.g., Th-232, Pu-239SS). 10CFR835.702(b) states:
The results of individual external and internal dose monitoring that is performed but not required by §835.402, shall be recorded.
What is your definition of recorded? Write on an official document and file it away? Record the dose and apply the results to the workers
annual report card?
25
Our Responses to Their Concerns If we are going to assign dose from a PAS,
why don’t we assign dose from the CAM? A CAM, unlike a PAS, is not always
representative of the air the worker breathed. If a CAM triggers a special bioassay, and the
CAM is representative, the dose calculated from a CAM can be used if the bioassay cannot refute it. Typically special bioassay can see less than the dose
from the CAM and/or RCO is reluctant to call the CAM representative for the worker.
26
Our Responses to Their Concerns If I had known people were being exposed, I
would have had RCO do something about it. Discussions on what is or is not a significant
exposure. If a person is in a NPFF respirator; air sample shows
100 DAC-hr; exposure is 2 DAC-hr. Anything to be gained by going to a air-supplied hood?
Worn under the hood, exposure could be higher depending on how well the hood removal goes.
Zero exposure to radionuclides is not an achievable goal.
27
Our Responses to Their Concerns No one told our workers they would get
internal dose assigned when wearing PAS. Hindsight: RCO should have explained this. To reduce worker ‘discomfort’ decided that the
2003 PAS doses were just practice. Real dose assignment will start in 2004
Developed a briefing sheet for RCO to use for worker briefing; became an Q&A to pass out. Facility RCO does briefing.
28
The Heart of the Matter? In my opinion, there were two recurring points
that drove the majority of management’s concern: Internal dose is worse then external dose.
I realize that from a technical standpoint you are probably right but I still think it is worse. A rem is not a rem.
I don’t want to deal with workers angst about getting dose they never were assigned before; especially if it is internal.
29
Revised Rules of Engagement An exposure of >8 DAC-hrs in one day will
trigger a special bioassay. An exposure of >40 DAC-hrs in a CY will
trigger a special bioassay. The special bioassay will be used to assign
dose unless the special bioassay cannot refute the exposure data.
30
Revised Rules of Engagement At the end of each Calendar Quarter, all
cumulative exposures based on counting results – not DAC-hrs, will be converted to dose using conservative DCFs. PAS results <DL are excluded Exposures >2.5 mrem are assigned
2.5 mrem/qtr equates to 10 mrem/yr. Aligns with the SRS method for assigning tritium doses.
31
Dose Calculation Output
32
The End of the Line CY2004 doses from PAS were posted
2/24/05; 7 months to resolve. 30 workers assigned doses ranging from 3 - 28
mrem for the year. 21 workers had a dose assignment of 3 - 9 mrem.
Plan to post Q1 of CY2005 on April 15. No feedback from Field on whether anyone has
been upset by this information. May depend on whether they are touched by the
upcoming layoff.