Top Banner
1 4100 Series Eurotherm Chessell’s New 100mm Recorders
31
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

1

4100 Series

Eurotherm Chessell’s

New 100mm Recorders

Page 2: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

2

Highlights

• Six new 100mm recorders offers widest choice of features and prices:

– 1-4 Pen Continuous recorders.

– 6 input Multipoint recorders.

• Choice of displays:– Classical Analogue.

– Simple Digital

– 4 colour Digital/ Analogue.

• Embedded Technology:– Custom D/A converters.

– High speed Multipoint printing head.

– Annotation for both Continuous and Multipoint.

– PCMCIA card readers.

– µ processor with powerful data handling.

• Compact size.

• Common Mechanics.

Page 3: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

3

Model No Type Displays Price

4101C Continuous Analogue Lowest

4101M Multipoint Analogue

4102C Continuous Simple Digital

4102M Multipoint Simple Digital

4103C Continuous Advanced Digital

4103M Multipoint Advanced Digital Highest

4100 Series

Page 4: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

4

Common Technologies

• 1-4 pen continuous & 6 input Multipoint.

• Compact size.

• Universal Isolated inputs.

• Annotation.

• State of the art mechanics.

• Universal Power Supply (90-260Vac)

• Fan-Fold cassette.

Page 5: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

5

Compact Size

27mm

200 mm220 mm

Maximum panelthickness = 25 mm

137mm

View on right hand side

236 mm

Terminal cover

Case clamp

144 mm

14

4 m

m

4101 Front view

0 20 40 60 80 100

0 50 100 150 200 250

-10 0 10

20 30 40

40 60 80 1000 20

144 mm

14

4 m

m

4102/3 Front view

• Din Standard 144X144 mm fits installed base of recorders.

• Standard cut-out for the complete range.

• Small depth behind panel allows for installation in 250mm deep cabinets.

• Weight = 5kg

Page 6: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

6

Universal Inputs

• Custom chipset gives one converter per channel.

• Wide range of input types.

• 250V isolation channel to channel & ground.

• High stability due to digital design.

• Universally calibrated to allow re-ranging later.

• Input accuracy 0.2%.

Page 7: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

7

Annotation

• Available on the complete range.

• Avoids use of custom overprinted charts.

• High speed annotation.– Uses dedicated print system on Continuous.

– High speed Multipoint printer allows fast text printing.

Page 8: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

8

Mechanical Innovation

• Contactless Feedback & Motor.– No wear & tear.

– High noise immunity.

• Multipoint Printing– Few moving parts = Higher reliability.

• No mechanical adjustments– For higher reliability and longer calibration intervals.

19

Motor Assembly Multipoint Printer

Page 9: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

9

4101 Basic Recorder

• High Pen Visibility.

• Analogue Display.

• Pre-configured to user’s specifications.

• Front access to electronic pen zero/span adjust.

• Overall accuracy 0.5%.

• Ready to go.

4101C

4101M

Page 10: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

10

4101 Charts

• Continuous:– Highest quality of trace.

– High speed variables.

• Multipoint:– Economic for 4 to 6 inputs.

– Slower moving variables.

Page 11: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

11

4101 Application

• Plant History:– Any continuous process.

• Machine Monitoring:– Sterilisation processes.

– Turbines.

– Furnaces.

– Electricity usage.

– Test Chambers

• Environmental Monitoring:

– Weather.

– Simple analytical.

• Where a simple, reliable recorder is needed for trending of a variable.

• Trends are all important not absolute values.

• Instrument configuration will not change.

• Price is all important.

Page 12: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

12

4102 Digital Recorder

• 3 colour Digital Display.

• Annotation.

• Chart Illumination.

• Front Access to pen zero/span adjust.

• Pre-configured to user’s specifications.

• PC configuration.

• 4 to 12 relay outputs.

• 2 to 4 analogue O/P.

• Overall accuracy 0.5%.

• Ready to Go.

4102C

4102M

Page 13: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

13

4102 Display

• 3 Colour Display

• Large 4 digit display of process values.

• High / Low alarm annunciator.

• Channel Indentification.

• 0.2% Display accuracy.

Alarmannunciators

Channelnumber

Displayhold indicator

Measured variable

Page 14: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

14

4102 Application

• Plant History:– Any continuous process.

• Machine Monitoring:– Sterilisation in line processes.

– Turbines.

– Furnaces.

– Electricity usage.

• Environmental Monitoring:– Weather.

– Simple analytical.

• Digital display is needed to obtain accurate values of the measured variables.

• Where a simple, reliable recorder is needed.

• There is occasional need for reconfiguration.

Page 15: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

15

4102 PC- Configuration

• Simple Channel by Channel Configuration.

• Uses standard PC with special RS232 cable.

• Allows filing of instrument configurations on Hard Disk.

Page 16: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

16

4102 Annotation

• Time & Date stamping.

• Zero and Span values.

• Channel identification.

• Engineering units.

• Continuous recorder has dedicated print head.

• Multipoint recorder uses 6 colour print head.

Page 17: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

17

4103 Intelligent Recorder

• 4 - Colour Digital Display

• User Programmable.

• Annotation.

• Universal Isolated I/P.

• Chart Illumination.

• Mathematical Data processing.

• Communications.

• 4 to 16 relay O/P.

• 2 to 4 Analogue O/P.

• 16 Contact I/P.

• Overall Accuracy 0.25%.

4103C

4103M

Page 18: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

18

4103 Display

• Versatile four colour VFD display.

• Easy to use programming keys.

• Clear multilingual programming prompts.

• Comprehensive alarm summary.

• 20 character custom message.

13

5

24

6

5 0 m A 1 0 0

A l a r s : ^ 2m 1 ^ 3 4

1234

456

C h a n n e l T a g U n i t s

Page 19: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

19

4103 Universal Inputs

• Custom chipset gives one converter per channel– 8x per second update , 2x per second 4103M

• 250V isolation channel to channel to ground

• High stability due to digital design

• Digital accuracy 0.1%

dc Volts dc mA T/C RTD

- 2 to 10V 0 to 20 mA B,C,E,J,K,N,R,S,T.

Pt100ANSI,DIN,JPT100

-20 to 100Vwith attenuator

ProgrammableShunt.

Ni/Ni Mo 18%,L, U, Platinel

Ni 100 & 120,Cu10, Pt 1000

Ohms Custom Lin. Flow Lin. Digital

0 to 9000 Ohms 32 segments , X 3/2, X 5/2 > 60 ms

Page 20: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

20

4103 Advanced Features

• Grouping of process variables:– Allows group orientated computation.

• Comprehensive mathematical processing.

• Alarm Monitoring.

• Application orientated timers, counters, totalisers.

• Job orientated logical functions.

• Input and paper calibration

Page 21: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

21

4103 Logs / Alarms• Alarm Functions:

– 4 alarms per channel:» Absolute High/Low.

» Deviation In/Out.

» Rate of change.

– Text messages on alarm

– Message to display for operator action

• Logging:– Columnar of group data.

– Custom messages with embedded data:

» Time

» DV’s

» Process Variable

Page 22: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

22

Timer / Counters/Totalisers6 of each

• Time:– Alarm on absolute time

– Alarm every:

» Minute

» Hour

» Day

» Month

» Year

• Counter:(Input is any Job or Contact)

Increment from start position.

– Decrement from start position.

– Reset.

– Alarm at any value.

– 8 Digit resolution.

• Totaliser:(Any analogue input)

– As above but integrating.

– Integration time & unit scalar programmable.

Page 23: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

23

Mathematical functions(12 DV’s 4103C, 16 DV’s 4103M)

• Basic - (level 1):– Constant.

– Copy.

– Add & Subtract.

– Divide & Multiply.

– Modulus.

• Advanced - (level 2):– Maths:

» Square Root.

» Loge & Log10

» ex & 10x

» Rate of Change.

» 3rd Order Polynomial.

– Timers

• Advanced:– Statistical:

» Average Channel or Group.

» Rolling Average.

» Sample & Hold.

» Channel Min & Max.

» Group Min & Max. (latched / continuous)

» High/Low select.

– Specials:

» Relative Humidity.

» Fo Value.

» Mass flow.

» Zirconia Probe.

Page 24: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

24

Jobs• Triggered by:

– Channel Alarm.

– Totalisers & Counter threshold.

– Timers.

– Events:

» Instrument alarms.

» Digital Channel.

» Event Input.

• Actions– Printing:

»Chart on/off.

»Alternate Chart speed.

»Print Log,scales or Custom Message.

»Change channel range.

– Resetting:

»Reset DV’s (1 or all).

»Reset/Preset Timer etc..

– Others:

»Drive relays or buzzer.

»Inc. / Dec. Counter.

»Start / Stop Timer.

»Memory card control.

»Alarm messages to display

Page 25: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

25

4103 PCMCIA Card

• Storing and/or transferring Configurations.

• Storing Logs and alarm messages as part of a Job.

• Storing at pre-set intervals for transfer to PC spreadsheet or database.

• Chart Copy to re-print charts.

• Packed data for greater storage in a secure format

Tank Monitor In Temp In Flow Out Flow Tank Level Total Deg C L/Sec L/Sec Meters Liters Messages

15/9/95 10:00:01 22.05 56 55 50.00 105000015/9/95 10:00:02 22.05 56 55 50.01 105001015/9/95 10:00:03 22.05 56 55 50.03 105002015/9/95 10:00:04 22.05 56 55 50.04 1050030 Tank Level High15/9/95 10:00:05 22.05 56 55 50.05 105004015/9/95 10:00:06 22.05 56 55 50.06 105005015/9/95 10:00:07 22.05 56 55 50.06 1050060

Page 26: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

26

4103 PC- Configuration

• Simple Channel by Channel configuration

• Can be done off-site on PC: – Using PCMCIA card to transfer data

– Incorporating a configuration print -dump

– Allows multiple configurations to be stored

– Ideal for complex configurations

Page 27: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

27

4103 Communications

• Physical Layer:– RS485 (compatible with RS232):

» Allows for up to 8 multidrop ports.

– Up to 19200 Baud.

• Protocol:– MODBUS RTU ®.

• Allows :– Transfer of measured variables to master.

– Transfer of data from master:» To be plotted as a channel.

» Used as variable in Maths operations.

» Used as an alarm set point.

Page 28: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

28

4103 High Definition TracingMultipoint

• 6 colour traces updated each second.

• Interpolation.

• Adaptive recording.

• Line thickening.

• User configurable tags.

• Flexible zoning & scaling.

• Text or trace priority modes and text only.

Page 29: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

29

4103 High Definition TracingContinuous

• Pen offset compensation.

• Flexible zoning & scaling.

• Dedicated print head for annotation.

• Derived 5th Channel Multipoint printing.

• Text or trace priority modes.

Page 30: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

30

4103 Application

• Process plant:– Mass flow totalisation.

– Plant monitor.

• Machine Monitoring:– Heat treatment.

– Sterilisation validation.

– Any machine QA documentation.

• Environmental Monitoring:

– Continuous Emission monitoring.

– Relative Humidity calculations.

– Multi stream analysis

• Where a complete log of the process is required to be used as a transaction document.

• Where communications are required with a central unit or SCADA package.

• Where PC after the event processing or analysis is required.

• When configuration change is frequent or uncertain at time of order.

Page 31: 1 4100 Series Eurotherm Chessell’s New 100mm Recorders.

31

Summary

• The 4100 series is designed to offer the user a wide choice of features and costs.

4101C 4101M 4102C 4102M 4103C 4103MContinuous Pen • • •Multipoint Dotter • • •Digital Display • • • •Programmable • •Annotation • • • •Relay Outputs • • • • • •Retransmission O/P • • • •Contact Inputs • •Communications • •Memory Card • •Chart Lighting • • • • • •PC Configuration • • • •Mathematics • •Counters, Totalisers,Timers • •