1 02/21/12 WEB Firmware Upgrade Procedure
112

1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

Dec 24, 2015

Download

Documents

Sydney McGee
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

1

02/21/12

WEB Firmware Upgrade Procedure

Page 2: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

2

IndexChapter 1 Hardware Connection

…………………………3Chapter 2 Firmware Upgrade Procedure &

Notice…………7 2.6 Firmware Upgrade From 1.1x or 1.20 to

P143 …………..18 2.7 Firmware Upgrade From 1.3x or 1.4x to

P143 ………..19

Chapter 3 Java-Based ProRAID Manager Uninstall / Install..20

Chapter 4 Boot Up Firmware Upgrade …………………....34

Chapter 5 SES Firmware Upgrade……………………….…42

Chapter 6 Controller Bridge Firmware 1.21 Upgrade Java-Based ...53

Chapter 7 Controller expander Firmware Upgrade Java-Based …...64

Chapter 8 Controller Firmware Upgrade Java-Based

………...…..75Chapter 9 Web-Based proRAID Manager

Firmware Upgrade ..84Chapter 10 Firmware1.42 Command Mode

Procedure …….106

Page 3: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

3

Chapter 1

Hardware Connection

Page 4: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

4

1.1 External RS232 Cable

Phone Jack – To RS232 of RAID Controller

DB9 – To RS232 of PC with Windows Hyper terminal

Page 5: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

5

1.2 RS232 Cable Install to RS232 Port of Controller 1

RS232 Port of Master Controller (Controller 1)

Phone Jack Type

To Enter console mode of Controller

You can open Windows Hyper terminal And Set up 115200,N,8,1 on your PC

Page 6: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

6

1.3 RS232 Cable Install to RS2323 port of SES Board

RS232 Port of SES2 : 115200,N,8,1 (Ver 2.x of PRO-90-5601)RS232 Port of SES : 38400,N,8,1 (Ver 1.x of PRO-90-6601)

Phone Jack Type

Page 7: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

7

Chapter 2

Firmware Upgrade Procedure & Notice

Page 8: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

8

2.1 Firmware Version List

Please follow below firmware version for your upgrading

Controller Firmware / Expander Firmware / proSES Firmware / Java Based GUI / Web Based GUI / Boot Code/ Controller Model 1.10 / v379 / 1.13 / 1.5.25 / Not Support / V3 1.11 / v379 / 1.13 / 1.5.25 / Not Support / V3 1.20 / v388 / 1.16 / 1.5.34 / Not Support / 39 / V3 V4 1.30 / v389 / 1.18 / 1.5.35 / Yes / 39 / V3 V4 1.31 / v407 / 1.19 / 1.5.37 / Yes / 39 / V3 V4 1.33 / v410 / 1.23 / 1.5.37 / Yes / 39 / V3 V4 1.40 / v410 / 1.24 / 1.5.37 / Yes / 44 / V3 V4 1.41 / v410 / 1.24 / 1.5.37 / Yes / 44 / V3 V4 1.42 / v410 / 1.24 / Not Support / Yes / 46 / V4 P143 / v410 / 1.24 / Not Support / Yes / 46 / V4

NOTE : 1. Please Upgrade Bridge firmware to 1.21 firstly if you want to upgrade firmware from 1.1x or 1.20 to 1.3x or 1.4x 2. Bootup46 , needed to upgrade first 3. P143 does not support controller serial series number 000000000303xxxx (V3 ) P143 only support controller serial series number 000000000304xxxx (V4) 4. Controller IP Addres will change to DHCP, please memo your IP address before upgrade. 5. Please upgrade firmware to 1.42 first and then follow below procedure chapter 2-6 2-7 before upgrade firmware P143. 6. Please use 1G or 2G memory for firmware upgrade

Page 9: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

9

2.2 Controller Model _V3 or V4 with Serial Number

V4 Controller 304xxxxV3 Controller 303xxxx

Page 10: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

10

proSES firmware version follow below procedure 1.13 1.16 1.19 1.23 1.24

Boot Code firmware version follow below procedure 37 39 44 46

2.3 Firmware Version List

Page 11: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

11

2.4 Save configuration files from Java-based proRAID Manager

Page 12: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

12

2.4 Configuration Save from Java-based proRAID Manager

Page 13: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

13

2.4 Configuration Save from Java-based proRAID Manager

Page 14: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

14

2.4 Configuration Save from Java-based proRAID Manager

Page 15: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

15

2.5 Configuration Save from Web-based proRAID Manager

Page 16: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

16

2.5 Configuration Save from Web-based proRAID Manager

Page 17: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

17

2.5 Configuration Save from Web-based proRAID Manager

Page 18: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

18

2.6 Firmware Upgrade From 1.1x or 1.20 to P143

Follow below rules For New Firmware Upgrade

From 1.1x or 1.20 to P143 (Java-Based proRAID Manager)

1.Please use 1G or 2G memory for firmware upgrade2.Configuration Save Files ( Chapter 2.4)3.Uninstall / Install Java-Based proRAID Manager (Chapter 3)4.Bootup Firmware 046 upgrade (Chapter 4)5.SES Firmware Upgrade to 1.24 (Chapter 5)6.Controller Bridge Firmware 1.21Upgrade (Chapter 6)7.Controller Expander Firmware Upgrade to v410 (Chapter 7)8.Bottom Board Expander firmware upgrade to v200 (Chapter 7)9.Controller Firmware Upgrade to 1.42 Java Based (Chapter 8)10.Firmware 1.42 Command mode Procedure (Chapter 10)11.Controller Firmware Upgrade from 1.42 to P143 web based (Chapter 9)

Controller Firmware version : P143 only support V4 Controller

Page 19: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

19

From 1.30 or 1.31 or 1.4x to P143 (Web-Based proRAID Manager)

1.Please use 1G or 2G memory for firmware upgrade2.Configuration Save Files (Chapter 2.5)3.Bootup Firmware to 046 upgrade (Chapter 4)4.SES Firmware Upgrade to 1.24 (Chapter 5) 5.Controller Expander Firmware Upgrade to v410 (Chapter 9.13)6.Bottom Board Expander firmware upgrade to v200 (Chapter 9.13)7.Controller Firmware Upgrade to 1.42 (Chapter 8)8.Firmware 1.42 Command mode Procedure (Chapter 10)9.Controller Firmware Upgrade from 1.42 to P143 web based (Chapter 9)

2.7 Firmware Upgrade From 1.3x or 1.4x to P143

Controller Firmware version : P143 only support V4 Controller

Page 20: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

20

Chapter 3

Java-BasedproRAID Manager

Uninstall / Install

Page 21: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

21

3.1 Uninstall proRAID Manager

Please go to the proRAID Manager files directory and run the uninstall program

For Uninstall proRAID Manager

Page 22: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

22

3.2 Install proRAID Manager

Insert CD

proRAIDManager

Page 23: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

23

3.3 Support OS

Platform includes Java VM

without Java VM

Instructions

MacOSX Download (12.6M)

View

Windows Download (39.6M)

View

AIX Download (72.1M)

View

HPUX Download (76.1M)

View

Linux Download (45.9M)

View

Solaris Download (65.8M)

View

Any Unix Platform Download (

13.4M) View

Solaris Intel Download (60.9M)

View

Other Java-enabled Platforms Download (

13.2M) View

Page 24: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

24

3.4 Install proRAID Manager on Windows

Windows Instructions:Instructions

After downloading, double-click install.exe

NotesYou do not need to install any other software. A Java virtual machine is included with this download.

(Go To Top)

Page 25: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

25

Mac OS X Instructions:Instructions

After downloading, double-click install

NotesBe sure you have Java installed. You can download Java from Apple's site The compressed installer should be recognized by Stuffit Expander and should automatically be expanded after downloading. If it is not expanded, you can expand it manually using StuffIt Expander 6.0 or later. If you have any problems launching the installer once it has been expanded, make sure that the compressed installer was expanded using Stuffit Expander. If you continue to have problems, please contact technical support.

(Go To Top)

3.5 Install proRAID Manager on MAC

Page 26: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

26

AIX Instructions:Instructions

After downloading open a shell and,  cd to the directory where you downloaded the installer. At the prompt type:  sh ./install.bin

NotesA Java virtual machine is included with this download. It will run automatically when you run the shell script.

(Go To Top)

3.6 Install proRAID Manager on Aix

Page 27: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

27

3.7 Install proRAID Manager on Solaris

Solaris Instructions:Instructions

After downloading open a shell and,  cd to the directory where you downloaded the installer. At the prompt type:  sh ./install.bin

NotesA Java virtual machine is included with this download. It will run automatically when you run the shell script.

(Go To Top)

Page 28: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

28

3.8 Install proRAID Manager on Linux

Linux Instructions:Instructions

After downloading open a shell and,  cd to the directory where you downloaded the installer. At the prompt type:  sh ./install.bin

NotesA Java virtual machine is included with this download. It will be run automatically when you run the shell script.

(Go To Top)

Page 29: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

29

3.9 Install proRAID Manager on HP-UX

HP-UX Instructions:Instructions

After downloading open a shell and,  cd to the directory where you downloaded the installer. At the prompt type:  sh ./install.bin

NotesA Java virtual machine is included with this download. It will be run automatically when you run the shell script.

(Go To Top)

Page 30: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

30

Solaris_Intel Instructions:Instructions

After downloading open a shell and,  cd to the directory where you downloaded the installer. At the prompt type:  sh ./install.bin

NotesA Java virtual machine is included with this download. It will be run automatically when you run the shell script.

(Go To Top)

3.10 Install proRAID Manager on Solaris_Intel

Page 31: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

31

Generic Unix Instructions:Instructions

After downloading open a shell and,  cd to the directory where you downloaded the installer. At the prompt type:  sh ./install.bin

NotesYou need to install a Java virtual machine. You can download one from Sun's Java web site or contact your OS manufacturer.

(Go To Top)

3.11 Install proRAID Manager on General_Unix

Page 32: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

32

All Other Platforms Instructions:Instructions (Unix or Unix-like operating systems)

For Java 2, after downloading, type  java -jar install.jar For Java 1.1, after downloading, type  jre -cp install.jar install If that does not work, try  java -classpath [path to]classes.zip:install.jar install If that does not work either, on sh-like shells, try  cd [to directory where install.jar is located]  CLASSPATH=install.jar  export CLASSPATH  java install Or for csh-like shells, try  cd [to directory where install.jar is located]  setenv CLASSPATH install.jar  java install

3.12 Install proRAID Manager on Other Platform

Page 33: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

33

Instructions (for other platforms)Be sure you have Java installed. You can download Java from Sun's site In a console window, change to the directory where you downloaded install.jar to before running the installer Your operating system may invoke Java in a different way. To start the installer, add install.jar to your CLASSPATH, then start the main class of the installer named install

3.13 Install proRAID Manager on Other Platform

Page 34: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

34

Chapter 4

Bootup

Firmware Upgrade

Page 35: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

35

How to upgrade the bootup46:1. Remove the controller – WARNING be careful to always remove the serial cable before removing the controller. This is because it is very easy to break the serial connector if you don't.2. Set the system to OPTION by setting the OPT switches to OFF-ON, where the first switch is next to the FibreChannel . These switches are tiny surface mounted and are located on the PCB next to the ethernet port.

Set the system to OPTION by setting the OPT switches to OFF-ON, where the first switch is next to the FibreChannel . These switches are tiny surface mounted and are located on the PCB next to the ethernet port.

4.1 Controller OPT switch

Page 36: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

36

4.1 Controller OPT switch

Set OPT switch equals to 1=OFF2=ON

Page 37: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

37

To avoid damaging the switches, use a wooden or plastic toothpick. Don't use a ball point or other pen because the ink will block the switch. 

4.1 Controller OPT switch

Page 38: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

38

1. Reinsert the controller (It is best to have only one controller in the system), attach serial cable.2. Open a HyperTerminal session and ensure the associated COM port is configured as follows:

- 115200 Baud - 8 Bit- No Parity- 1 Stop- No flow control

3. Power up and you should see the following FC-SAS Bootup version 44, code mode VERBOSE, option MONITOR. DDR-SDRAM num_ranks 2 num_banks 4 MB0CF reg 40 mode 201 MB0CF reg 44 mode 201 mq setup dimm 0 ranks 2 size 134217728

4.2 Power up

Page 39: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

39

mq reg 40 val f000 mq reg 41 val 800f000 RQFD 37, RFFD 21a DDR DRAM size = 1073741824 ------------------------------------- processor name : 440SPe processor PVR value : 0x53421891 total SDRAM memory : 1073741824 system clk period (ps) : 30303 system clk frequency (Hz): 33000033 VCO frequency : 990000990 CPU frequency : 495000495 PLB frequency : 165000165 OPB frequency : 82500082 EBC frequency : 82500082 MAL frequency : 82500082 PCI frequency : 100-133MHz TMR frequency : 495000495 uart 0 clk frequency : 3402410316 uart 1 clk frequency : 372207941 PCI arbiter : Disabled bootstrap setting : 0x857cf2c6 0x05900401 SDRAM running at : DDR1 cpld version : 0x00 ------------------------------------- Run monitor code. ************************************************* flash utility version 44 ************************************************* upgrade>>

4.3 Messages after Power up

Page 40: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

40

1.Next upgrade the bootup by typing “bootup” and send the file bootup46.srec using HyperTerminal menu Transfer->Send Text File.

Do not use X/Y/ZMODEM. This will take about 1-2 minutes to download. You should see * characters being printed out if the download is working.

upgrade>>bootup ---Bootup module--- Pls send your S-Record file ... done! Total bytes: 492eb Flash write address from fffe0000, total size 0x20000, total sector 2 Flash sector fffe0000 erase successful! Flash sector ffff0000 erase successful! Writing flash ... ******************************************************* Flash write successful! Flash ChkSum sector fffb0000 erase successful! Writing flash ... Flash write ChkSum 0xe9d98477 successful!

upgrade>>

4.4 Bootup firmware upgrade

Page 41: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

41

2. Power off the enclosures3. Remove the controller and put the OPTION switches back to OPT 1=OFF 2=OFF -this puts the controller into the normal mode.

4. Reinsert the controller and power on.

4.5 OPT Switch return to Normal

Page 42: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

42

Chapter 5

SES

Firmware Upgrade

Page 43: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

43

To upgrade the SES firmware, first you need to check SES board version number. Check in the LCD display the SES version (use arrow down key).

“SES2” means Version 2.x of PRO-90-5601 SES boardPRO-90-5601 Baud Rate Terminal Setting is 115200.

5.1 SES Boards Version

Page 44: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

44

5.2 SES2 (5601) Board

PRO-90-5601 Ver: 2.xTerminal Settings : 115200,8,N,1,N

Another option is to check the SES board version. Power off the RAID subsystem and remove the SES module. Check the board version from the label marked on the SES board.

Page 45: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

45

5.3 SES2 (5601) Upgrade Procedure – Setup

1.Connect RS232 serial cable to the RS232 port of SES module.

2.Open terminal connection and configure terminal settings as follows:Baud Rate: 115200Data Bits: 8Parity: NoneStop Bits: 1Flow Control: None

Page 46: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

46

5.4 SES2 (5601) Upgrade Procedure - Upgrading

1. Press Enter and you will see the symbol of arrow 2. Please Key the “proses upgrade” proses upgrade3. Press Q then will have CCCC words display

Page 47: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

47

5.4 SES2 (5601) Upgrade Procedure - Upgrading

Click “Transfer” “Send File” tab

Page 48: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

48

5.4 SES2 (5601) Upgrade Procedure - Upgrading

EP95601_118.bin

EP95601_118.bin

Ymodem

1.Select Ymodem

2. Click Browse tabSelect Firmware File “EP95601_119.bin” For PRO-90-5601.

Page 49: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

49

Notice!

Power off / on and then next step

5.5 Power Off / On

Page 50: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

50

1. LCD Panel You can refer chapter 4.1

2. SES Borad command Line proses version

5.6 SES Firmware version confirm

You can refer the below chart of 6.2 and 6.3 for command mode using.

--> proses versionSES2 F/W V:1.19 for VSC7153-=-=-= Build time:Jul 9 2008 15:39:52 -=-=-=-

Page 51: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

51

3. Controller command Line You can login to console of controller via RS232 cable. ( Refer chapter 1.1 ~ 1.2 )

login: rootPassword:00000000# qmplease put a commandshow enclosuresthanksprocessing command line: show enclosures

Enclosure 0x1: i-Stor xxxxxxxx 1.19Status : 0xff

* Type below command

5.6 SES Firmware version confirm

Page 52: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

52

Notice!

Power off / on and then next step

5.7 Power Off / On

Page 53: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

53

Chapter 6

Controller

Bridge Firmware 1.21 Upgrade

JAVA-

Based proRAID Manager

Page 54: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

54

6.1 Java-Based proRAID Manager – Start Up

1. Click “start Program proRAIDManager proRAIDManager” on Windows

2. Click “search” tab then will display the RAID subsystem with ip address List, please double clicks you want to manage ip item

Page 55: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

55

6.2 Java-Based proRAID Manager – User name & Password

Enter the User Name : admin Password : admin

Page 56: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

56

6.3 Java-Based proRAID Manager – LAN Connection

On Line : You can upgrade firmware from your PC to Controller

Page 57: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

57

Off Line : You can not upgrade firmware from your PC to Controller

6.4 Java-Based proRAID Manager – LAN Connection

Page 58: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

58

2.2 Upgrade Firmware from proRAID ManagerClick the “Administration” tab and choose “Service Options”

6.5 Java-Based proRAID Manager – Controller Bridge Firmware Upgrade

Version1.20

Page 59: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

59

Choose “Upgrade Controller” tab

6.5 Java-Based proRAID Manager – Controller Bridge Firmware Upgrade

Page 60: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

60

Please Select 1.21 bridge firmware file : EP-901045-1.21.bin

5.2 Controller Bridge Firmware upgrade

EP-901045-1.21.bin

EP-901045-1.21.bin

6.5 Java-Based proRAID Manager – Controller Bridge Firmware Upgrade

Page 61: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

61

Click “Yes” and will take several minutes

Notice :Firmware will auto upgrade to controller 2 if you have redundant controllers model.

2.2 Upgrade Firmware from proRAID Manager

6.5 Java-Based proRAID Manager – Controller Bridge Firmware Upgrade

Page 62: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

62

6.6 Controller Bridge Firmware Version Confirm

Click Monitoring System Information

Page 63: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

63

6.7 Power off / power on

Notice!

Power off / on and then next step

Page 64: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

64

Chapter 7

Controller Expander

Firmware Upgrade

JAVA-Based proRAID Manager

Page 65: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

65

7.1 Java-Based proRAID Manager – Start Up

1. Click “start Program proRAIDManager proRAIDManager” on Windows

2. Click “search” tab then will display the RAID subsystem with ip address List, please double clicks you want to manage ip item

Page 66: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

66

7.2 Java-Based proRAID Manager – User name & Password

Enter the User Name : admin Password : admin

Page 67: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

67

7.3 Java-Based proRAID Manager – Controller Expander Upgrade

Click the “Administration” tab and choose “Service Options”

Page 68: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

68

Choose “Upgrade Controller” tab

7.4 Java-Based proRAID Manager – Controller Expander Upgrade

Page 69: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

69

Select All Files on File Type item and choose you want upgrade expander firmware version.

7.5 Java-Based proRAID Manager – Controller Expander Upgrade

All Files

V 407.s3r

V 407.s3rFile Name

File Type

Page 70: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

70

7.6 Java-Based proRAID Manager – Controller Expander Upgrade

Click OK

OK

Page 71: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

71

7.7 Java-Based proRAID Manager – Controller Expander Upgrade

OK

Click OK

Page 72: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

72

Notice!

Upgrading could take several minutes to complete. It is recommended to stop all access to the system and it takes around 4 minutes to upgrade each expander on the background.

7.8 Upgrading could take several minutes to complete

Page 73: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

73

7.9 Controller Expander Firmware Version Confirm

Click Monitoring System Information

Page 74: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

74

7.10 Power off / power on

Notice!

Power off / on and then next step

Page 75: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

75

Chapter 8

Controller

Firmware Upgrade

JAVA-Based proRAID Manager

Page 76: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

76

8.1 Java-Based proRAID Manager – Start Up

1. Click “start Program proRAIDManager proRAIDManager” on Windows

2. Click “search” tab then will display the EP-3169 RAID subsystem with ip address List, please double clicks you want to manage ip item

Page 77: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

77

8.2 Java-Based proRAID Manager – User name & Password

Enter the User Name : admin Password : admin

Page 78: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

78

Click the “Administration” tab and choose “Service Options”

8.3 Java-Based proRAID Manager – Controller Firmware Upgrade

Page 79: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

79

Choose “Upgrade Controller” tab

8.4 Java-Based proRAID Manager – Controller Firmware Upgrade

Page 80: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

80

Select you want to upgrade firmware version

8.5 Java-Based proRAID Manager – Controller Firmware Upgrade

EP-901045-1.31.bin

EP-901045-1.31.binFile Name

File Type

Page 81: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

81

Notice !Don’t Click “Yes”, please click “No”

8.6 Java-Based proRAID Manager – Controller Firmware Upgrade

Page 82: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

82

8.7 Power off / on

Notice!

Power off / on and we can run Web GUI normally

Page 83: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

83

8.8 Controller Firmware Version Confirm

Click Monitoring System Information

Page 84: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

84

Chapter 9

Web-BasedproRAID Manager Firmware

Upgrade

Page 85: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

85

9.1 Show IP address - LCD Panel

You can get the IP address show on LCD Panel

This menu displays the Controller IP address. Pressing the button will display second controller’s IP address.

In a single controller configuration, the second controller’s IP address will be shown as 0.0.0.0.

The IP display need to wait 2 Minutes after you power on

The IP display need to wait 15 Minutes after you change IP address

Pro-90-6601 SES Board can’t show IP Address on LCD Panel

Page 86: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

86

9.2 Show IP address - Console of Controller

You can see the IP address on console for 6601(SES) boardLogin to console of controller via RS232 cable.( Refer Chapter1.2 )

Login : netadmin

************Current ip setting********* Dynamic Ip address netmask ::: 255.255.0.0 inet addr ::: 10.11.1.40 gateway ::: 10.11.1.3 dns1 ::: 10.11.1.2 dns2 ::: 84.203.255.34 domain ::: raidtec.ie ***************** end ************** please enter a command

Type command follow left table

Page 87: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

87

9.2 Web-Based proRAID Manager – User name and Password

1. Open Web Browser and Type your IP address

2. User Name : admin Password : admin

Page 88: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

88

9.3 Web-Based proRAID Manager - Enable proRAID Manager

How to change to Java-based from Web-based proRAID manager on firmware 1.30?(1.31 or later firmware version no this item.)

Click Administration Enable RAID Manager AppNotice !Web GUI is the default Management tool when you power on with 1.30 firmware.

1.31or later firmware version can both start up web-based and java-based proRAID Manager.

Page 89: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

89

9.4 Web-Based proRAID Manager - Enable Web GUI

You can return to Web GUI Management with 1.30 firmware. (1.31 or later firmware version no this item)

Type IP Address on Web Browser Click Enable Web GUI

Page 90: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

90

9.5 Controller Firmware Version Confirm

Click Information System Information

Page 91: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

91

9.6 Expander Firmware Version Confirmation From Web

Click Information System Information

Page 92: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

92

9.7 Upgrade from 1.30 to higher

User Name : adminPassword : admin

Open Web Browser and Type your IP address

Page 93: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

93

9.7 Upgrade from 1.30 to higher

Click on “Administration>Upgrade Firmware” menu

Page 94: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

94

9.8 Locate the FW File

Click on “Browse” to locate the firmware

Page 95: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

95

9.9 Upgrade process

Click on “Upgrade” button to start the firmware upgrade process

NOTE: Stop all RAID operation e.g. “Rebuild, Initialization, verify” and host access before proceeding to upgrade

Page 96: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

96

9.10 Upgrade in progress

Upgrade in progress

NOTE: For dual controller, the firmware will auto upgrade the other boards.

Page 97: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

97

9.11 Upgrade Complete

Upgrade Complete.

Press “RESET” button to take effect the new firmware version

Page 98: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

98

9.11 Upgrade Complete

System Online after reset, the i-Stor is now ready to use.

Page 99: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

99

9.12 Verify New Version

Click “System Information “menu to verify new version.

EP-3169D-F4S3

Page 100: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

100

9.13 Upgrading the Expanders

Click on “Administration>Upgrade Firmware” menu to upgrade the expander firmware

Page 101: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

101

9.14 Locate the Expander FW File

Click on “Browse” to locate the expander firmware ,the firmware should in .s3r extension

Page 102: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

102

9.15 Expander Upgrade Start

Click on “Upgrade” button to start the expander firmware upgrade process

NOTE: Stop all RAID operation e.g. “Rebuild, Initialization, verify” and host access before proceeding to upgrade the expander.

Page 103: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

103

9.16 Upgrade in progress

Firmware uploading in progress

NOTE: For i-Stor dual controller and i-Stor Jbod , the firmware will auto upgrade the expanders firmware on the other boards and on the jbod. Each expanders upgrade process will take around 3~5 minutes.

Page 104: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

104

9.17 Background Install Background installation is progress.

NOTE: For i-Stor dual controller and i-Stor Jbod , the firmware will auto upgrade the expanders firmware on the other boards and on the jbod. Each expanders upgrade process will take around 3~5 minutes.

Page 105: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

105

9.18 Verify new Firmware version

NOTE: For dual controller, the firmware will auto upgrade the expanders firmware on the other boards.

Click “System Information” menu

Expander New Firmware version

Page 106: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

106

Firmware1.42 Command Mode Procedure

Chapter 10

Page 107: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

107

How to upgrade to P143 FW from firmware version 1.42

NOTE: Due P143 firmware version needs 11MB flash size, it is required to resize the flash partition of each controllers (000000000304xxxx). Controller 1 Partition Resize    A. Attached RS232 cable to the controller 1 RS232 port.    B. Open HyperTerminal, set setting to 115200-8-N-1   C. Login using username: “root” and password “00000000”   D. On the console, verify the controller flash is 16MB , type “flashctl -p /dev/fs0 -I” # flashctl -p /dev/fs0 -i

Array Info Total      :  0x01000000  100% Chip Size :  0x01000000  100%                         Unit Size :  0x00020000    0%

 The above results show “Chip Size:  0x01000000 100%” that controller is 16MB Flash E. Now resize the partition using the following command “init_flash_fs.sh force upgrade16mb”

# init_flash_fs.sh force upgrade16mb erasing old fs on 16MB chip building 11MB filesystem on 16MB chip

F. Verify if the partition is 11MB size, type “df”# df /dev/fs0p1   22016      1051     20964       5%  /fs0p1

G: After all steps is successful, the controller 2 needs to be resize. Follow the next procedure to resize the controller 2 flash.NOTE: DO NOT POWER CYCLE after resizing the partition

10.1 Run the command with firmware 1.42

Page 108: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

108

 Controller 2 Partition Resize      A. Attached RS232 cable to the controller 2 RS232 port.      B. Open HyperTerminal, set setting to 115200-8-N-1     C. Login using username: “root” and password “00000000”     D. On the console, verify the controller flash is 16MB , type “flashctl -p /dev/fs0 -I” # flashctl -p /dev/fs0 -i

Array Info Total      :  0x01000000  100% Chip Size :  0x01000000  100%                         Unit Size :  0x00020000    0%

 The above results show “Chip Size:  0x01000000 100%” that controller is 16MB Flash E. Now resize the partition using the following command “init_flash_fs.sh force upgrade16mb”

# init_flash_fs.sh force upgrade16mb erasing old fs on 16MB chip building 11MB filesystem on 16MB chip

F. Verify if the partition is 11MB size, type “df”# df /dev/fs0p1   22016      1051     20964       5%  /fs0p1

G: After all steps is successful, Both controller 1 and 2 are now ready for P143 upgrade via web proRAIDManager

10.1 Run the command with firmware 1.42

Page 109: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

109

NOTE: DO NOT POWER CYCLE after resizing the partitionH.# qmReset board allI. For WEB-GUI, update /etc/boa/boa.conf to allow up to 5MB code size, for the Controller with WEB-GUI access. # cat >> /etc/boa/boa.conf <blank> SinglePostLimit 0x500000 [CNTL].[D] #

J. Restart BOA # slay boa [19/Nov/2010:13:57:45 +0000] caught SIGTERM, starting shutdown [19/Nov/2010:13:57:45 +0000] exiting Boa normally (uptime 816 seconds)

10.1 Run the command with firmware 1.42

Page 110: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

110

Controller 1 & Controller 2 IP address change to DHCP, you can change the ip address from netadmin via RS232login: netadmin ************Current ip setting********* Dynamic Ip address netmask ::: 255.255.255.0 inet addr ::: 192.168.220.229 gateway ::: 192.168.220.6 dns1 ::: 168.95.192.1 dns2 ::: 168.95.1.1 domain ::: ***************** end ************** -------------- Commands Available ------------ set ip <ip_address> set ip <ip_address> <net_mask> set ip <ip_address> <net_mask><gateway> set ip dynamic /*Enable dhcp*/ show ip /*List ip settings*/ menu /*List available commands*/ exit /*Exit netadmin*/ -------------- end ------------please enter a commandset ip 192.168.220.61

10.2 Set up your IP from DHCP

Page 111: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

111

Upgrade to P143 FW from firmware version 1.42 from web proRAID Manager      A) Open the web proRAID MANAGER B) Login using username “admin” and password “admin” C) In the Administration>>Upgrade Firmware screen on the web browser, click            Browse' and select the file containing the firmware version P143 (EP-901045-P143.bin).     D) To begin the firmware upgrade, click the “Upgrade” .button NOTE: Do not perform any other actions until a message is displayed confirming          that the installation is finished.     E) If a system reset is needed to run the new firmware, you will be prompted          to do so at this point. F) Power cycle the enclosure so the new firmware to take effect. 

10.3 Upgrade firmware from 1.42 to P143

Page 112: 1 02/21/12 WEB Firmware Upgrade Procedure. 2 Index Chapter 1 Hardware Connection …………………………3 Chapter 2 Firmware Upgrade Procedure & Notice…………7 2.6 Firmware.

112

Do againController 1 & Controller 2 IP address change to DHCP, you can change the ip address from netadmin via RS232login: netadmin ************Current ip setting********* Dynamic Ip address netmask ::: 255.255.255.0 inet addr ::: 192.168.220.229 gateway ::: 192.168.220.6 dns1 ::: 168.95.192.1 dns2 ::: 168.95.1.1 domain ::: ***************** end ************** -------------- Commands Available ------------ set ip <ip_address> set ip <ip_address> <net_mask> set ip <ip_address> <net_mask><gateway> set ip dynamic /*Enable dhcp*/ show ip /*List ip settings*/ menu /*List available commands*/ exit /*Exit netadmin*/ -------------- end ------------please enter a commandset ip 192.168.220.61

10.4 Set IP again from DHCP