1 02/21/12 WEB Firmware Upgrade Procedure
1
02/21/12
WEB Firmware Upgrade Procedure
2
IndexChapter 1 Hardware Connection
…………………………3Chapter 2 Firmware Upgrade Procedure &
Notice…………7 2.6 Firmware Upgrade From 1.1x or 1.20 to
P143 …………..18 2.7 Firmware Upgrade From 1.3x or 1.4x to
P143 ………..19
Chapter 3 Java-Based ProRAID Manager Uninstall / Install..20
Chapter 4 Boot Up Firmware Upgrade …………………....34
Chapter 5 SES Firmware Upgrade……………………….…42
Chapter 6 Controller Bridge Firmware 1.21 Upgrade Java-Based ...53
Chapter 7 Controller expander Firmware Upgrade Java-Based …...64
Chapter 8 Controller Firmware Upgrade Java-Based
………...…..75Chapter 9 Web-Based proRAID Manager
Firmware Upgrade ..84Chapter 10 Firmware1.42 Command Mode
Procedure …….106
3
Chapter 1
Hardware Connection
4
1.1 External RS232 Cable
Phone Jack – To RS232 of RAID Controller
DB9 – To RS232 of PC with Windows Hyper terminal
5
1.2 RS232 Cable Install to RS232 Port of Controller 1
RS232 Port of Master Controller (Controller 1)
Phone Jack Type
To Enter console mode of Controller
You can open Windows Hyper terminal And Set up 115200,N,8,1 on your PC
6
1.3 RS232 Cable Install to RS2323 port of SES Board
RS232 Port of SES2 : 115200,N,8,1 (Ver 2.x of PRO-90-5601)RS232 Port of SES : 38400,N,8,1 (Ver 1.x of PRO-90-6601)
Phone Jack Type
7
Chapter 2
Firmware Upgrade Procedure & Notice
8
2.1 Firmware Version List
Please follow below firmware version for your upgrading
Controller Firmware / Expander Firmware / proSES Firmware / Java Based GUI / Web Based GUI / Boot Code/ Controller Model 1.10 / v379 / 1.13 / 1.5.25 / Not Support / V3 1.11 / v379 / 1.13 / 1.5.25 / Not Support / V3 1.20 / v388 / 1.16 / 1.5.34 / Not Support / 39 / V3 V4 1.30 / v389 / 1.18 / 1.5.35 / Yes / 39 / V3 V4 1.31 / v407 / 1.19 / 1.5.37 / Yes / 39 / V3 V4 1.33 / v410 / 1.23 / 1.5.37 / Yes / 39 / V3 V4 1.40 / v410 / 1.24 / 1.5.37 / Yes / 44 / V3 V4 1.41 / v410 / 1.24 / 1.5.37 / Yes / 44 / V3 V4 1.42 / v410 / 1.24 / Not Support / Yes / 46 / V4 P143 / v410 / 1.24 / Not Support / Yes / 46 / V4
NOTE : 1. Please Upgrade Bridge firmware to 1.21 firstly if you want to upgrade firmware from 1.1x or 1.20 to 1.3x or 1.4x 2. Bootup46 , needed to upgrade first 3. P143 does not support controller serial series number 000000000303xxxx (V3 ) P143 only support controller serial series number 000000000304xxxx (V4) 4. Controller IP Addres will change to DHCP, please memo your IP address before upgrade. 5. Please upgrade firmware to 1.42 first and then follow below procedure chapter 2-6 2-7 before upgrade firmware P143. 6. Please use 1G or 2G memory for firmware upgrade
9
2.2 Controller Model _V3 or V4 with Serial Number
V4 Controller 304xxxxV3 Controller 303xxxx
10
proSES firmware version follow below procedure 1.13 1.16 1.19 1.23 1.24
Boot Code firmware version follow below procedure 37 39 44 46
2.3 Firmware Version List
11
2.4 Save configuration files from Java-based proRAID Manager
12
2.4 Configuration Save from Java-based proRAID Manager
13
2.4 Configuration Save from Java-based proRAID Manager
14
2.4 Configuration Save from Java-based proRAID Manager
15
2.5 Configuration Save from Web-based proRAID Manager
16
2.5 Configuration Save from Web-based proRAID Manager
17
2.5 Configuration Save from Web-based proRAID Manager
18
2.6 Firmware Upgrade From 1.1x or 1.20 to P143
Follow below rules For New Firmware Upgrade
From 1.1x or 1.20 to P143 (Java-Based proRAID Manager)
1.Please use 1G or 2G memory for firmware upgrade2.Configuration Save Files ( Chapter 2.4)3.Uninstall / Install Java-Based proRAID Manager (Chapter 3)4.Bootup Firmware 046 upgrade (Chapter 4)5.SES Firmware Upgrade to 1.24 (Chapter 5)6.Controller Bridge Firmware 1.21Upgrade (Chapter 6)7.Controller Expander Firmware Upgrade to v410 (Chapter 7)8.Bottom Board Expander firmware upgrade to v200 (Chapter 7)9.Controller Firmware Upgrade to 1.42 Java Based (Chapter 8)10.Firmware 1.42 Command mode Procedure (Chapter 10)11.Controller Firmware Upgrade from 1.42 to P143 web based (Chapter 9)
Controller Firmware version : P143 only support V4 Controller
19
From 1.30 or 1.31 or 1.4x to P143 (Web-Based proRAID Manager)
1.Please use 1G or 2G memory for firmware upgrade2.Configuration Save Files (Chapter 2.5)3.Bootup Firmware to 046 upgrade (Chapter 4)4.SES Firmware Upgrade to 1.24 (Chapter 5) 5.Controller Expander Firmware Upgrade to v410 (Chapter 9.13)6.Bottom Board Expander firmware upgrade to v200 (Chapter 9.13)7.Controller Firmware Upgrade to 1.42 (Chapter 8)8.Firmware 1.42 Command mode Procedure (Chapter 10)9.Controller Firmware Upgrade from 1.42 to P143 web based (Chapter 9)
2.7 Firmware Upgrade From 1.3x or 1.4x to P143
Controller Firmware version : P143 only support V4 Controller
20
Chapter 3
Java-BasedproRAID Manager
Uninstall / Install
21
3.1 Uninstall proRAID Manager
Please go to the proRAID Manager files directory and run the uninstall program
For Uninstall proRAID Manager
22
3.2 Install proRAID Manager
Insert CD
proRAIDManager
23
3.3 Support OS
Platform includes Java VM
without Java VM
Instructions
MacOSX Download (12.6M)
View
Windows Download (39.6M)
View
AIX Download (72.1M)
View
HPUX Download (76.1M)
View
Linux Download (45.9M)
View
Solaris Download (65.8M)
View
Any Unix Platform Download (
13.4M) View
Solaris Intel Download (60.9M)
View
Other Java-enabled Platforms Download (
13.2M) View
24
3.4 Install proRAID Manager on Windows
Windows Instructions:Instructions
After downloading, double-click install.exe
NotesYou do not need to install any other software. A Java virtual machine is included with this download.
(Go To Top)
25
Mac OS X Instructions:Instructions
After downloading, double-click install
NotesBe sure you have Java installed. You can download Java from Apple's site The compressed installer should be recognized by Stuffit Expander and should automatically be expanded after downloading. If it is not expanded, you can expand it manually using StuffIt Expander 6.0 or later. If you have any problems launching the installer once it has been expanded, make sure that the compressed installer was expanded using Stuffit Expander. If you continue to have problems, please contact technical support.
(Go To Top)
3.5 Install proRAID Manager on MAC
26
AIX Instructions:Instructions
After downloading open a shell and, cd to the directory where you downloaded the installer. At the prompt type: sh ./install.bin
NotesA Java virtual machine is included with this download. It will run automatically when you run the shell script.
(Go To Top)
3.6 Install proRAID Manager on Aix
27
3.7 Install proRAID Manager on Solaris
Solaris Instructions:Instructions
After downloading open a shell and, cd to the directory where you downloaded the installer. At the prompt type: sh ./install.bin
NotesA Java virtual machine is included with this download. It will run automatically when you run the shell script.
(Go To Top)
28
3.8 Install proRAID Manager on Linux
Linux Instructions:Instructions
After downloading open a shell and, cd to the directory where you downloaded the installer. At the prompt type: sh ./install.bin
NotesA Java virtual machine is included with this download. It will be run automatically when you run the shell script.
(Go To Top)
29
3.9 Install proRAID Manager on HP-UX
HP-UX Instructions:Instructions
After downloading open a shell and, cd to the directory where you downloaded the installer. At the prompt type: sh ./install.bin
NotesA Java virtual machine is included with this download. It will be run automatically when you run the shell script.
(Go To Top)
30
Solaris_Intel Instructions:Instructions
After downloading open a shell and, cd to the directory where you downloaded the installer. At the prompt type: sh ./install.bin
NotesA Java virtual machine is included with this download. It will be run automatically when you run the shell script.
(Go To Top)
3.10 Install proRAID Manager on Solaris_Intel
31
Generic Unix Instructions:Instructions
After downloading open a shell and, cd to the directory where you downloaded the installer. At the prompt type: sh ./install.bin
NotesYou need to install a Java virtual machine. You can download one from Sun's Java web site or contact your OS manufacturer.
(Go To Top)
3.11 Install proRAID Manager on General_Unix
32
All Other Platforms Instructions:Instructions (Unix or Unix-like operating systems)
For Java 2, after downloading, type java -jar install.jar For Java 1.1, after downloading, type jre -cp install.jar install If that does not work, try java -classpath [path to]classes.zip:install.jar install If that does not work either, on sh-like shells, try cd [to directory where install.jar is located] CLASSPATH=install.jar export CLASSPATH java install Or for csh-like shells, try cd [to directory where install.jar is located] setenv CLASSPATH install.jar java install
3.12 Install proRAID Manager on Other Platform
33
Instructions (for other platforms)Be sure you have Java installed. You can download Java from Sun's site In a console window, change to the directory where you downloaded install.jar to before running the installer Your operating system may invoke Java in a different way. To start the installer, add install.jar to your CLASSPATH, then start the main class of the installer named install
3.13 Install proRAID Manager on Other Platform
34
Chapter 4
Bootup
Firmware Upgrade
35
How to upgrade the bootup46:1. Remove the controller – WARNING be careful to always remove the serial cable before removing the controller. This is because it is very easy to break the serial connector if you don't.2. Set the system to OPTION by setting the OPT switches to OFF-ON, where the first switch is next to the FibreChannel . These switches are tiny surface mounted and are located on the PCB next to the ethernet port.
Set the system to OPTION by setting the OPT switches to OFF-ON, where the first switch is next to the FibreChannel . These switches are tiny surface mounted and are located on the PCB next to the ethernet port.
4.1 Controller OPT switch
36
4.1 Controller OPT switch
Set OPT switch equals to 1=OFF2=ON
37
To avoid damaging the switches, use a wooden or plastic toothpick. Don't use a ball point or other pen because the ink will block the switch.
4.1 Controller OPT switch
38
1. Reinsert the controller (It is best to have only one controller in the system), attach serial cable.2. Open a HyperTerminal session and ensure the associated COM port is configured as follows:
- 115200 Baud - 8 Bit- No Parity- 1 Stop- No flow control
3. Power up and you should see the following FC-SAS Bootup version 44, code mode VERBOSE, option MONITOR. DDR-SDRAM num_ranks 2 num_banks 4 MB0CF reg 40 mode 201 MB0CF reg 44 mode 201 mq setup dimm 0 ranks 2 size 134217728
4.2 Power up
39
mq reg 40 val f000 mq reg 41 val 800f000 RQFD 37, RFFD 21a DDR DRAM size = 1073741824 ------------------------------------- processor name : 440SPe processor PVR value : 0x53421891 total SDRAM memory : 1073741824 system clk period (ps) : 30303 system clk frequency (Hz): 33000033 VCO frequency : 990000990 CPU frequency : 495000495 PLB frequency : 165000165 OPB frequency : 82500082 EBC frequency : 82500082 MAL frequency : 82500082 PCI frequency : 100-133MHz TMR frequency : 495000495 uart 0 clk frequency : 3402410316 uart 1 clk frequency : 372207941 PCI arbiter : Disabled bootstrap setting : 0x857cf2c6 0x05900401 SDRAM running at : DDR1 cpld version : 0x00 ------------------------------------- Run monitor code. ************************************************* flash utility version 44 ************************************************* upgrade>>
4.3 Messages after Power up
40
1.Next upgrade the bootup by typing “bootup” and send the file bootup46.srec using HyperTerminal menu Transfer->Send Text File.
Do not use X/Y/ZMODEM. This will take about 1-2 minutes to download. You should see * characters being printed out if the download is working.
upgrade>>bootup ---Bootup module--- Pls send your S-Record file ... done! Total bytes: 492eb Flash write address from fffe0000, total size 0x20000, total sector 2 Flash sector fffe0000 erase successful! Flash sector ffff0000 erase successful! Writing flash ... ******************************************************* Flash write successful! Flash ChkSum sector fffb0000 erase successful! Writing flash ... Flash write ChkSum 0xe9d98477 successful!
upgrade>>
4.4 Bootup firmware upgrade
41
2. Power off the enclosures3. Remove the controller and put the OPTION switches back to OPT 1=OFF 2=OFF -this puts the controller into the normal mode.
4. Reinsert the controller and power on.
4.5 OPT Switch return to Normal
42
Chapter 5
SES
Firmware Upgrade
43
To upgrade the SES firmware, first you need to check SES board version number. Check in the LCD display the SES version (use arrow down key).
“SES2” means Version 2.x of PRO-90-5601 SES boardPRO-90-5601 Baud Rate Terminal Setting is 115200.
5.1 SES Boards Version
44
5.2 SES2 (5601) Board
PRO-90-5601 Ver: 2.xTerminal Settings : 115200,8,N,1,N
Another option is to check the SES board version. Power off the RAID subsystem and remove the SES module. Check the board version from the label marked on the SES board.
45
5.3 SES2 (5601) Upgrade Procedure – Setup
1.Connect RS232 serial cable to the RS232 port of SES module.
2.Open terminal connection and configure terminal settings as follows:Baud Rate: 115200Data Bits: 8Parity: NoneStop Bits: 1Flow Control: None
46
5.4 SES2 (5601) Upgrade Procedure - Upgrading
1. Press Enter and you will see the symbol of arrow 2. Please Key the “proses upgrade” proses upgrade3. Press Q then will have CCCC words display
47
5.4 SES2 (5601) Upgrade Procedure - Upgrading
Click “Transfer” “Send File” tab
48
5.4 SES2 (5601) Upgrade Procedure - Upgrading
EP95601_118.bin
EP95601_118.bin
Ymodem
1.Select Ymodem
2. Click Browse tabSelect Firmware File “EP95601_119.bin” For PRO-90-5601.
49
Notice!
Power off / on and then next step
5.5 Power Off / On
50
1. LCD Panel You can refer chapter 4.1
2. SES Borad command Line proses version
5.6 SES Firmware version confirm
You can refer the below chart of 6.2 and 6.3 for command mode using.
--> proses versionSES2 F/W V:1.19 for VSC7153-=-=-= Build time:Jul 9 2008 15:39:52 -=-=-=-
51
3. Controller command Line You can login to console of controller via RS232 cable. ( Refer chapter 1.1 ~ 1.2 )
login: rootPassword:00000000# qmplease put a commandshow enclosuresthanksprocessing command line: show enclosures
Enclosure 0x1: i-Stor xxxxxxxx 1.19Status : 0xff
* Type below command
5.6 SES Firmware version confirm
52
Notice!
Power off / on and then next step
5.7 Power Off / On
53
Chapter 6
Controller
Bridge Firmware 1.21 Upgrade
JAVA-
Based proRAID Manager
54
6.1 Java-Based proRAID Manager – Start Up
1. Click “start Program proRAIDManager proRAIDManager” on Windows
2. Click “search” tab then will display the RAID subsystem with ip address List, please double clicks you want to manage ip item
55
6.2 Java-Based proRAID Manager – User name & Password
Enter the User Name : admin Password : admin
56
6.3 Java-Based proRAID Manager – LAN Connection
On Line : You can upgrade firmware from your PC to Controller
57
Off Line : You can not upgrade firmware from your PC to Controller
6.4 Java-Based proRAID Manager – LAN Connection
58
2.2 Upgrade Firmware from proRAID ManagerClick the “Administration” tab and choose “Service Options”
6.5 Java-Based proRAID Manager – Controller Bridge Firmware Upgrade
Version1.20
59
Choose “Upgrade Controller” tab
6.5 Java-Based proRAID Manager – Controller Bridge Firmware Upgrade
60
Please Select 1.21 bridge firmware file : EP-901045-1.21.bin
5.2 Controller Bridge Firmware upgrade
EP-901045-1.21.bin
EP-901045-1.21.bin
6.5 Java-Based proRAID Manager – Controller Bridge Firmware Upgrade
61
Click “Yes” and will take several minutes
Notice :Firmware will auto upgrade to controller 2 if you have redundant controllers model.
2.2 Upgrade Firmware from proRAID Manager
6.5 Java-Based proRAID Manager – Controller Bridge Firmware Upgrade
62
6.6 Controller Bridge Firmware Version Confirm
Click Monitoring System Information
63
6.7 Power off / power on
Notice!
Power off / on and then next step
64
Chapter 7
Controller Expander
Firmware Upgrade
JAVA-Based proRAID Manager
65
7.1 Java-Based proRAID Manager – Start Up
1. Click “start Program proRAIDManager proRAIDManager” on Windows
2. Click “search” tab then will display the RAID subsystem with ip address List, please double clicks you want to manage ip item
66
7.2 Java-Based proRAID Manager – User name & Password
Enter the User Name : admin Password : admin
67
7.3 Java-Based proRAID Manager – Controller Expander Upgrade
Click the “Administration” tab and choose “Service Options”
68
Choose “Upgrade Controller” tab
7.4 Java-Based proRAID Manager – Controller Expander Upgrade
69
Select All Files on File Type item and choose you want upgrade expander firmware version.
7.5 Java-Based proRAID Manager – Controller Expander Upgrade
All Files
V 407.s3r
V 407.s3rFile Name
File Type
70
7.6 Java-Based proRAID Manager – Controller Expander Upgrade
Click OK
OK
71
7.7 Java-Based proRAID Manager – Controller Expander Upgrade
OK
Click OK
72
Notice!
Upgrading could take several minutes to complete. It is recommended to stop all access to the system and it takes around 4 minutes to upgrade each expander on the background.
7.8 Upgrading could take several minutes to complete
73
7.9 Controller Expander Firmware Version Confirm
Click Monitoring System Information
74
7.10 Power off / power on
Notice!
Power off / on and then next step
75
Chapter 8
Controller
Firmware Upgrade
JAVA-Based proRAID Manager
76
8.1 Java-Based proRAID Manager – Start Up
1. Click “start Program proRAIDManager proRAIDManager” on Windows
2. Click “search” tab then will display the EP-3169 RAID subsystem with ip address List, please double clicks you want to manage ip item
77
8.2 Java-Based proRAID Manager – User name & Password
Enter the User Name : admin Password : admin
78
Click the “Administration” tab and choose “Service Options”
8.3 Java-Based proRAID Manager – Controller Firmware Upgrade
79
Choose “Upgrade Controller” tab
8.4 Java-Based proRAID Manager – Controller Firmware Upgrade
80
Select you want to upgrade firmware version
8.5 Java-Based proRAID Manager – Controller Firmware Upgrade
EP-901045-1.31.bin
EP-901045-1.31.binFile Name
File Type
81
Notice !Don’t Click “Yes”, please click “No”
8.6 Java-Based proRAID Manager – Controller Firmware Upgrade
82
8.7 Power off / on
Notice!
Power off / on and we can run Web GUI normally
83
8.8 Controller Firmware Version Confirm
Click Monitoring System Information
84
Chapter 9
Web-BasedproRAID Manager Firmware
Upgrade
85
9.1 Show IP address - LCD Panel
You can get the IP address show on LCD Panel
This menu displays the Controller IP address. Pressing the button will display second controller’s IP address.
In a single controller configuration, the second controller’s IP address will be shown as 0.0.0.0.
The IP display need to wait 2 Minutes after you power on
The IP display need to wait 15 Minutes after you change IP address
Pro-90-6601 SES Board can’t show IP Address on LCD Panel
86
9.2 Show IP address - Console of Controller
You can see the IP address on console for 6601(SES) boardLogin to console of controller via RS232 cable.( Refer Chapter1.2 )
Login : netadmin
************Current ip setting********* Dynamic Ip address netmask ::: 255.255.0.0 inet addr ::: 10.11.1.40 gateway ::: 10.11.1.3 dns1 ::: 10.11.1.2 dns2 ::: 84.203.255.34 domain ::: raidtec.ie ***************** end ************** please enter a command
Type command follow left table
87
9.2 Web-Based proRAID Manager – User name and Password
1. Open Web Browser and Type your IP address
2. User Name : admin Password : admin
88
9.3 Web-Based proRAID Manager - Enable proRAID Manager
How to change to Java-based from Web-based proRAID manager on firmware 1.30?(1.31 or later firmware version no this item.)
Click Administration Enable RAID Manager AppNotice !Web GUI is the default Management tool when you power on with 1.30 firmware.
1.31or later firmware version can both start up web-based and java-based proRAID Manager.
89
9.4 Web-Based proRAID Manager - Enable Web GUI
You can return to Web GUI Management with 1.30 firmware. (1.31 or later firmware version no this item)
Type IP Address on Web Browser Click Enable Web GUI
90
9.5 Controller Firmware Version Confirm
Click Information System Information
91
9.6 Expander Firmware Version Confirmation From Web
Click Information System Information
92
9.7 Upgrade from 1.30 to higher
User Name : adminPassword : admin
Open Web Browser and Type your IP address
93
9.7 Upgrade from 1.30 to higher
Click on “Administration>Upgrade Firmware” menu
94
9.8 Locate the FW File
Click on “Browse” to locate the firmware
95
9.9 Upgrade process
Click on “Upgrade” button to start the firmware upgrade process
NOTE: Stop all RAID operation e.g. “Rebuild, Initialization, verify” and host access before proceeding to upgrade
96
9.10 Upgrade in progress
Upgrade in progress
NOTE: For dual controller, the firmware will auto upgrade the other boards.
97
9.11 Upgrade Complete
Upgrade Complete.
Press “RESET” button to take effect the new firmware version
98
9.11 Upgrade Complete
System Online after reset, the i-Stor is now ready to use.
99
9.12 Verify New Version
Click “System Information “menu to verify new version.
EP-3169D-F4S3
100
9.13 Upgrading the Expanders
Click on “Administration>Upgrade Firmware” menu to upgrade the expander firmware
101
9.14 Locate the Expander FW File
Click on “Browse” to locate the expander firmware ,the firmware should in .s3r extension
102
9.15 Expander Upgrade Start
Click on “Upgrade” button to start the expander firmware upgrade process
NOTE: Stop all RAID operation e.g. “Rebuild, Initialization, verify” and host access before proceeding to upgrade the expander.
103
9.16 Upgrade in progress
Firmware uploading in progress
NOTE: For i-Stor dual controller and i-Stor Jbod , the firmware will auto upgrade the expanders firmware on the other boards and on the jbod. Each expanders upgrade process will take around 3~5 minutes.
104
9.17 Background Install Background installation is progress.
NOTE: For i-Stor dual controller and i-Stor Jbod , the firmware will auto upgrade the expanders firmware on the other boards and on the jbod. Each expanders upgrade process will take around 3~5 minutes.
105
9.18 Verify new Firmware version
NOTE: For dual controller, the firmware will auto upgrade the expanders firmware on the other boards.
Click “System Information” menu
Expander New Firmware version
106
Firmware1.42 Command Mode Procedure
Chapter 10
107
How to upgrade to P143 FW from firmware version 1.42
NOTE: Due P143 firmware version needs 11MB flash size, it is required to resize the flash partition of each controllers (000000000304xxxx). Controller 1 Partition Resize A. Attached RS232 cable to the controller 1 RS232 port. B. Open HyperTerminal, set setting to 115200-8-N-1 C. Login using username: “root” and password “00000000” D. On the console, verify the controller flash is 16MB , type “flashctl -p /dev/fs0 -I” # flashctl -p /dev/fs0 -i
Array Info Total : 0x01000000 100% Chip Size : 0x01000000 100% Unit Size : 0x00020000 0%
The above results show “Chip Size: 0x01000000 100%” that controller is 16MB Flash E. Now resize the partition using the following command “init_flash_fs.sh force upgrade16mb”
# init_flash_fs.sh force upgrade16mb erasing old fs on 16MB chip building 11MB filesystem on 16MB chip
F. Verify if the partition is 11MB size, type “df”# df /dev/fs0p1 22016 1051 20964 5% /fs0p1
G: After all steps is successful, the controller 2 needs to be resize. Follow the next procedure to resize the controller 2 flash.NOTE: DO NOT POWER CYCLE after resizing the partition
10.1 Run the command with firmware 1.42
108
Controller 2 Partition Resize A. Attached RS232 cable to the controller 2 RS232 port. B. Open HyperTerminal, set setting to 115200-8-N-1 C. Login using username: “root” and password “00000000” D. On the console, verify the controller flash is 16MB , type “flashctl -p /dev/fs0 -I” # flashctl -p /dev/fs0 -i
Array Info Total : 0x01000000 100% Chip Size : 0x01000000 100% Unit Size : 0x00020000 0%
The above results show “Chip Size: 0x01000000 100%” that controller is 16MB Flash E. Now resize the partition using the following command “init_flash_fs.sh force upgrade16mb”
# init_flash_fs.sh force upgrade16mb erasing old fs on 16MB chip building 11MB filesystem on 16MB chip
F. Verify if the partition is 11MB size, type “df”# df /dev/fs0p1 22016 1051 20964 5% /fs0p1
G: After all steps is successful, Both controller 1 and 2 are now ready for P143 upgrade via web proRAIDManager
10.1 Run the command with firmware 1.42
109
NOTE: DO NOT POWER CYCLE after resizing the partitionH.# qmReset board allI. For WEB-GUI, update /etc/boa/boa.conf to allow up to 5MB code size, for the Controller with WEB-GUI access. # cat >> /etc/boa/boa.conf <blank> SinglePostLimit 0x500000 [CNTL].[D] #
J. Restart BOA # slay boa [19/Nov/2010:13:57:45 +0000] caught SIGTERM, starting shutdown [19/Nov/2010:13:57:45 +0000] exiting Boa normally (uptime 816 seconds)
10.1 Run the command with firmware 1.42
110
Controller 1 & Controller 2 IP address change to DHCP, you can change the ip address from netadmin via RS232login: netadmin ************Current ip setting********* Dynamic Ip address netmask ::: 255.255.255.0 inet addr ::: 192.168.220.229 gateway ::: 192.168.220.6 dns1 ::: 168.95.192.1 dns2 ::: 168.95.1.1 domain ::: ***************** end ************** -------------- Commands Available ------------ set ip <ip_address> set ip <ip_address> <net_mask> set ip <ip_address> <net_mask><gateway> set ip dynamic /*Enable dhcp*/ show ip /*List ip settings*/ menu /*List available commands*/ exit /*Exit netadmin*/ -------------- end ------------please enter a commandset ip 192.168.220.61
10.2 Set up your IP from DHCP
111
Upgrade to P143 FW from firmware version 1.42 from web proRAID Manager A) Open the web proRAID MANAGER B) Login using username “admin” and password “admin” C) In the Administration>>Upgrade Firmware screen on the web browser, click Browse' and select the file containing the firmware version P143 (EP-901045-P143.bin). D) To begin the firmware upgrade, click the “Upgrade” .button NOTE: Do not perform any other actions until a message is displayed confirming that the installation is finished. E) If a system reset is needed to run the new firmware, you will be prompted to do so at this point. F) Power cycle the enclosure so the new firmware to take effect.
10.3 Upgrade firmware from 1.42 to P143
112
Do againController 1 & Controller 2 IP address change to DHCP, you can change the ip address from netadmin via RS232login: netadmin ************Current ip setting********* Dynamic Ip address netmask ::: 255.255.255.0 inet addr ::: 192.168.220.229 gateway ::: 192.168.220.6 dns1 ::: 168.95.192.1 dns2 ::: 168.95.1.1 domain ::: ***************** end ************** -------------- Commands Available ------------ set ip <ip_address> set ip <ip_address> <net_mask> set ip <ip_address> <net_mask><gateway> set ip dynamic /*Enable dhcp*/ show ip /*List ip settings*/ menu /*List available commands*/ exit /*Exit netadmin*/ -------------- end ------------please enter a commandset ip 192.168.220.61
10.4 Set IP again from DHCP