ISSUE ISSUE Fixed Network Curriculum Development Section 0AX001111 SoftX3000 Hardware &Software Installation 2.0 2.0
ISSUEISSUE
Fixed Network Curriculum
Development Section
Fixed Network Curriculum
Development Section
0AX001111 SoftX3000 Hardware&Software Installation
0AX001111 SoftX3000 Hardware&Software Installation
2.02.0
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
2
ReviewReview
According to the normal installation sequence,
the installation of equipment can be divided i
nto three major parts: hardware installation, s
oftware installation and data configuration & s
oftware debugging. Mainly presents the basic
procedures of U-SYS SoftX3000 hardware&sof
tware installation and describes them in detail.
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
3
ObjectivesObjectives
Mainly presents the basic procedures
of U-SYS SoftX3000 hardware&softwa
re installation and describes them in d
etail.
Upon completion of this course,you will be able to:
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
4
ReferencesReferences
SoftX3000 Package of Documents V300R001 (V3.06)
U-SYS SoftX3000 Hardware Installation Manual(V3.06)
U-SYS SoftX3000 Software Installation Manual(V3.06)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
5
Course ContentsCourse Contents
Chapter 1 Overview
Chapter 2 Installing Signal Cables
Chapter 3 software installation
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
6
Chapter 1 the Chapter NameChapter 1 the Chapter Name
Physical structure of SoftX3000
Hardware installation process of SoftX3000
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
7
structure of CN16IP frame structure of CN16IP frame
Back boards
Front boards
Backplane
Service boards System management boards
Service boards Alarm board
Power boards
Ethernet communication boards Power boardsInterface boards Interface boards
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
8
Physical Structure of SoftX3000Physical Structure of SoftX3000
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
9
Hardware installation process of SoftX3000 Hardware installation process of SoftX3000 Start
Installing client software
Installing iGWB software
End
Preparations
Installing BAM server software
Installing emergency workstation software
Installing billing workstation software
Configuring remote maintenance system
Checking Installed Software
Loading software and data to host
Start
Installing client software
Installing iGWB software
End
Preparations
Installing BAM server software
Installing emergency workstation software
Installing billing workstation software
Configuring remote maintenance system
Checking Installed Software
Loading software and data to host
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
10
SummarySummary
Physical structure of SoftX3000
Hardware installation process of SoftX3000
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
11
Course ContentsCourse Contents
Chapter 1 Overview
Chapter 2 Installing Signal Cables
Chapter 3 software installation
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
12
Chapter 2 Installing Signal Cables Chapter 2 Installing Signal Cables
2.1 Overview 2.1 Overview
2.2 Installing Internal Cables
2.3 Installing External Cables
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
13
Classification of Signal Cables Classification of Signal Cables
The internal signal cables
Straight through network cable between LAN Switches
Straight through network cable between iGWB/BAM and LA
N Switch
Straight through network cables between boards in service
frame and LAN Switch
FE signal cable between HSCI and SIUI
Serial port cable between iGWB servers
Data cable between iGWB server and hard disk array
Server/Switcher cable
Serial port cable for monitoring power distribution frame
Internal clock cable(optional)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
14
Classification of Signal CablesClassification of Signal Cables
External signal cables
Trunk cable(optional)
External clock cable(optional)
External network cable
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
15
Connection of internal cables in integrated configuration cabinet
Connection of internal cables in integrated configuration cabinet
(1)Power distribution frame(2)Expansion frame(3)Basic frame(4)Slave iGWB(5)Master iGWB
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
16
Chapter 2 Installing Signal Cables Chapter 2 Installing Signal Cables
2.1 Overview
2.2 Installing Internal Cables2.2 Installing Internal Cables
2.3 Installing External Cables
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
17
Process for installing internal signal cablesProcess for installing internal signal cables
Installing FE signal cable between HSCI and SIUI
Installing straight through network cables between iGWB/BAM and LAN Switch
Installing straight through cables between boards in service frame and LAN Switch
End of internal cables installation
Installing data cable between iGWB and hard disk array
Installing serial port cable between iGWBs
Installing straight through network cable between LAN Switches
End of power cables and grounding cables
installation
Installing Server/Switcher cable
Installing cable for monitoring power distribution frame
Installing internal clock cable (optional)
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
18
Straight Through Network Cable between LAN Switches
Straight Through Network Cable between LAN Switches
The two S3526 LAN
Switches are
interconnected with one
another with a straight
through cable. They work
in dual backup mode. The
dual backup mode, which
is adopted to ensure data
security, means that the
two LAN Switches detect
each other's heartbeat
signal.
X1 X2 Remark
1 1A twisted pair
2 2
3 3A twisted pair
4 4
5 5A twisted pair
6 6
7 7A twisted pair
8 8
Appearance of straight through network cable
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
19
Straight Through Network Cable between iGWB/BAM and LAN Switch
Straight Through Network Cable between iGWB/BAM and LAN Switch
Three servers (two iGWBs and one BAM) are configured i
n the integrated configuration cabinet, and each server us
es two straight through network cables to connect with th
e active & standby LAN Switches
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
20
Straight Through Network Cable between LAN Switch and HSCI Board
Straight Through Network Cable between LAN Switch and HSCI Board
In integrated configuration cabinet and service processing
cabinet, there are six 10/100M network ports on both active
and standby HSCI boards in each basic/expansion frame. The
ports labeled 10/100BT6 at the uppermost position of the
active/standby HSCI boards are connected to the active and
standby LAN Switches respectively through straight through
cables, realizing not only the communication between the
service processing subsystem and BAM, but also the
interconnection between the service processing frames.
The connection positions on the front panel of LAN Switch
are determined by port configuration scheme.
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
21
Straight Through Network Cable between HSCI and SIUI
Straight Through Network Cable between HSCI and SIUI
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
22
Serial Port Signal Cable between iGWBsSerial Port Signal Cable between iGWBs
To ensure the dual backup working mode of iGWB, and in
view of security design, the two iGWBs in the integrated c
onfiguration cabinet need to be connected by serial port c
able to form the second heartbeat signal transfer path for
the dual backup mode. The connection port is the RS232
serial port at the back of iGWB server, located above VGA
interface
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
23
Data Signal Cable between iGWB and Hard Disk Array
Data Signal Cable between iGWB and Hard Disk Array
Connection position of data signal cable on iGWB
Two pieces of SCSI data cables between iGWB and hard disk array are provided by the manufacturer of hard disk array. One end of the data cable connects with SCSI socket on iGWB, and the other end connects to the SCSI socket on the u
pper part of hard disk array
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
24
Connection of server/switcher cableConnection of server/switcher cable
iGWB0
KVM switcher
iGWB1
BAM
PC3 PC2PC4 PC1
iGWB0
KVM switcher
iGWB1
BAM
PC3 PC2PC4 PC1
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
25
Serial Port Cables for Monitoring Power Distribution Frame
Serial Port Cables for Monitoring Power Distribution Frame
The signal monitoring of the power distribution frame is
carried out by SMUI board of service frame. On the
monitor board of the power distribution frame, there are
two RS485 serial ports serving as the active and standby
power monitor ports, which are connected with the active
and standby monitor ports of SIUI board of the service
frame through the serial port cables to send the monitor
signals of the power distribution frame to the
background. Each cabinet is connected with two serial
port cables.
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
26
Appearance of the monitor cable and the cable connection relations
Appearance of the monitor cable and the cable connection relations
X1.1 X2.1 TX+A twisted pair
X1.2 X2.2 TX-
X1.4 X2.4 RX+ A twisted pair
X1.5 X2.5 RX-
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
27
Chapter 2 Installing Signal Cables Chapter 2 Installing Signal Cables
2.1 Overview
2.2 Installing Internal Cables
2.3 Installing External Cables 2.3 Installing External Cables
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
28
Flow of installing external signal cableFlow of installing external signal cable
Installing external clock cable (optional)
End of external signal cable installation
End of internal signal cable installation
Installing trunk cable (optional)
Installing external network cable
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
29
Trunk Cable between SoftX3000 and Digital Distribution Frame
Trunk Cable between SoftX3000 and Digital Distribution Frame
Two types of trunk cable are adopted in SoftX3000: 75
E1 trunk cable and 120 E1 trunk cable. Both the two
types of trunk cable adopt DB50 high density connector
with a locker for fixing.
The EPII boards are configured in active/standby mode,
and only the active EPII board is connected with the trunk
cable through its DB50 trunk port, as shown in Figure 6-
18. After out of the panel of EPII, the trunk cables pass
through the cabling trough of the cabinet in horizontal
direction, and then are out of the cabinet by upward or
downward cabling along the left column of the cabinet.
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
30
Appearance of 75 E1 trunk cableAppearance of 75 E1 trunk cable
(1) DB50 公接头(2) 主标签(3) 标签(4) 小标签
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
31
Appearance of 120 E1 trunk cable Appearance of 120 E1 trunk cable
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
32
Connection position of trunk cableConnection position of trunk cable
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
33
External Clock Cable between SoftX3000 and BITSExternal Clock Cable between SoftX3000 and BITS
External clock cable is used to connect the
active/standby CKII board with BITS, adopting 75Ω
coaxial cable.
BITS outputs two types of clock signals, including 2-MHz
analog clock signal and 2-Mbit/s digital clock signal.
When SoftX3000 adopts 2-MHz signal, the active and
standby clock cables connect respectively with the
corresponding SMB connectors LINE1 and LINE2 of CKII
boards in the basic frame. When SoftX3000 adopts 2-
Mbit/s signals, the active and standby clock cables
connect respectively with the corresponding SMB
connectors BITS1 and BITS2 of CKII boards in the basic
frame
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
34
Connection of external clock cable Connection of external clock cable
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
35
External network cableExternal network cable
External network cable is used to connect SoftX3000 with
external network devices, and the external network interfa
ces in SoftX3000 are provided by the corresponding back
interface boards. The media resource server is also conn
ected to SoftX3000 through external networking devices.
The active and standby MRIAs, MPCs and SCCs are conn
ected to the external Routers or LAN Switches through th
e external network cables.
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
36
SummarySummary
The signal cables are divided into internal signal cables
and external signal cables. Among the external signal
cables, the clock cable, trunk cable and external network
cable are optional depending on the actual hardware
configuration.
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
37
Course ContentsCourse Contents
Chapter 1 Overview
Chapter 2 Installing Signal Cables
Chapter 3 software installation
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
38
Chapter 3 software installationChapter 3 software installation
2.1 Overview2.1 Overview
2.2 Installing BAM Server Software
2.3 Installing Client Software
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
39
Overall StructureOverall Structure
SoftX3000 software system structure
Host software
Host
Terminal OAM
software
BAM
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
40
Software Configuration ListSoftware Configuration List
DeviceOperating
systemDatabase software Application software Preinstalled software
BAMWindows 2000 Server plus service pack 4
SQL Server 2000 plus service pack 3
BAM software
1) Windows 2000 Server plus service pack 42) SQL Server 2000 plus service pack 3
Ordinary workstation
1) Windows NT2) Windows XP3) Windows 2000
None
SoftX3000 operation & maintenance client software
None
Emergency workstation
Windows 2000 Server plus service pack4
SQL Server 2000 plus service pack 3
Emergency workstation software
1) Windows 2000 Server plus service pack 42) SQL Server 2000 plus service pack 3
iGWBWindows 2000 Server plus service pack 3
NoneBilling gateway software
Windows 2000 Server plus service pack 3
Billing workstation
1) Windows NT2) Windows XP3) Windows 2000
NoneBilling gateway client software
None
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
41
Overall Installation ProcessOverall Installation Process
Start
Installing client software
Installing iGWB software
End
Preparations
Installing BAM server software
Installing emergency workstation software
Installing billing workstation software
Configuring remote maintenance system
Checking Installed Software
Loading software and data to host
Start
Installing client software
Installing iGWB software
End
Preparations
Installing BAM server software
Installing emergency workstation software
Installing billing workstation software
Configuring remote maintenance system
Checking Installed Software
Loading software and data to host
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
42
Chapter 3 software installationChapter 3 software installation
2.1 Overview
2.2 Installing BAM Server Software2.2 Installing BAM Server Software
2.3 Installing Client Software
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
43
Software architecture Software architecture
BAM software architecture
Windows 2000 Server
BAM server software
SQL Server 2000
Application layer
Operating system layer
IBM server hardware platform
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
44
BAM software installation before deliveryBAM software installation before delivery
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
45
On-site installationOn-site installation
S ta r t
C h e c k w h e th e r t h e o p e r a t in g s y s te m a n d d a ta b a s e r u n
n o r m a lly
M o d i f y t h e a d m in is t r a to r p a s s w o r d o f S Q L S e r v e r
2 0 0 0
M o d i f y IP a d d r e s s e s o f n e t w o r k a d a p te r s
I n s ta ll t h e B A M s e r v e r s o f tw a r e
E n d
M o d i f y t h e c o m p u te r n a m e
N o
Y e sP e r f o r m f a c t o r y i n s t a l l a t io n
M o d i f y t h e a d m in is t r a to r p a s s w o r d o f W in d o w s 2 0 0 0
S e r v e r
M o d i f y f a c t o r y - d e f a u l t s e t t i n g s
S e t a u to m a t ic lo g in t o W in d o w 2 0 0 0 s e r v e r
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
46
Chapter 3 software installationChapter 3 software installation
2.1 Overview
2.2 Installing BAM Server Software
2.3 Installing Client Software2.3 Installing Client Software
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
47
Client Software architecture Client Software architecture
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
48
Software requirementSoftware requirement
Software type Version
Microsoft Windows NT
Microsoft Windows XP
Microsoft Windows 2000
Client software SoftX3000 V300R001
Internet ExplorerMicrosoft Internet Explorer 5.5 or later
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
49
Installation ProcedureInstallation Procedure
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
50
SummarySummary
Like the normal order of project construction, equipment i
nstallation falls into three stages, namely hardware install
ation, software installation, and data configuration & soft
ware debugging. This slide details the basic software inst
allation process of U-SYS SoftX3000 SoftSwitch System
(hereinafter referred to as SoftX3000).
Confidential Information of Huawei. No Spreading without Permission.
Security Level: Internal
51