Top Banner
victaulic.com 08.41 12808 Rev C Updated 03/2020 © 2020 Victaulic Company. All rights reserved. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. Series 725S with Manual Gear Operator Series 725S with Pneumatic Actuator Series 725S with Hydraulic Actuator Series 725S with Electric Actuator 1.0 PRODUCT DESCRIPTION Available Sizes • 4"/DN100 • 6"/DN150 • 8"/DN200 Maximum Working Pressure • 1500 psi/10342 kPa Function • Three-way, two position diverter valve with stainless steel wetted surfaces Pipe Preparation • Victaulic Original Groove System (OGS)/EndSeal™ (ES) Groove System: Prepare pipe ends in accordance with Publication 25.02 • Victaulic Style 808 High Pressure Coupling System: Prepare pipe ends in accordance with Publication 25.04 • Victaulic Style 809N High Pressure Coupling Ring System: Prepare pipe ends in accordance with Publication I-809N Application • Intended for backfill diversion in backfill mining operations and similar abrasive services • Intended for flush water diversion in backfill mining operations and similar abrasive services • May be operated under pressure to dump backfill in the event of a blockage Actuation Options • Manual: gear operator with limit stop, hand wheel, flange according to EN ISO 5211 • Manual: gear operator with limit stop, chain wheel, flange according to EN ISO 5211 • Pneumatic actuator: pneumatic vane motor with electronic positioning feedback mounted to gear operator (flange according to EN ISO 5211) • Hydraulic actuator: hydraulic vane motor with electronic positioning feedback mounted to gear operator (flange according to EN ISO 5211) • Electric actuator: multi-turn electric actuator mounted to gear operator (flange according to EN ISO 5211) Victaulic ® Diverter Valve Series 725S 08.41 1 System No. Location Submitted By Date Spec Section Paragraph Approved Date
6

08.41 Series 725S Diverter Valve Submittal | Victaulic · Series 725S with Manual Gear Operator Series 725S with Pneumatic Actuator Series 725S with Hydraulic Actuator Series 725S

Jul 31, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 08.41 Series 725S Diverter Valve Submittal | Victaulic · Series 725S with Manual Gear Operator Series 725S with Pneumatic Actuator Series 725S with Hydraulic Actuator Series 725S

victaulic.com 08.41 12808 Rev C Updated 03/2020 © 2020 Victaulic Company. All rights reserved.

ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT.

Series 725S with Manual Gear Operator

Series 725S with Pneumatic Actuator

Series 725S with Hydraulic Actuator

Series 725S with Electric Actuator

1.0 PRODUCT DESCRIPTION

Available Sizes• 4"/DN100

• 6"/DN150

• 8"/DN200

Maximum Working Pressure• 1500 psi/10342 kPa

Function• Three-way, two position diverter valve with stainless steel wetted surfaces

Pipe Preparation• Victaulic Original Groove System (OGS)/EndSeal™ (ES) Groove System: Prepare pipe ends in accordance with

Publication 25.02

• Victaulic Style 808 High Pressure Coupling System: Prepare pipe ends in accordance with Publication 25.04

• Victaulic Style 809N High Pressure Coupling Ring System: Prepare pipe ends in accordance with Publication I-809N

Application• Intended for backfill diversion in backfill mining operations and similar abrasive services

• Intended for flush water diversion in backfill mining operations and similar abrasive services

• May be operated under pressure to dump backfill in the event of a blockage

Actuation Options• Manual: gear operator with limit stop, hand wheel, flange according to EN ISO 5211

• Manual: gear operator with limit stop, chain wheel, flange according to EN ISO 5211

• Pneumatic actuator: pneumatic vane motor with electronic positioning feedback mounted to gear operator (flange according to EN ISO 5211)

• Hydraulic actuator: hydraulic vane motor with electronic positioning feedback mounted to gear operator (flange according to EN ISO 5211)

• Electric actuator: multi-turn electric actuator mounted to gear operator (flange according to EN ISO 5211)

Victaulic® Diverter ValveSeries 725S 08.41

1

System No. Location

Submitted By Date

Spec Section Paragraph

Approved Date

Page 2: 08.41 Series 725S Diverter Valve Submittal | Victaulic · Series 725S with Manual Gear Operator Series 725S with Pneumatic Actuator Series 725S with Hydraulic Actuator Series 725S

08.41 12808 Rev C Updated 03/2020 © 2020 Victaulic Company. All rights reserved.

victaulic.com

2.0 CERTIFICATION/LISTINGS

3.0 SPECIFICATIONS – MATERIAL

Cover: ASTM A216 Grade WCB

Inlet Cap/Body/Plug/Drive Stem: ASTM A743 Grade CA6NM, martensitic stainless steel

Body Sleeve/Top Seal: PTFE

Seat: Polyurethane

Gasket and O-Rings1: Grade “T” Nitrile

Nitrile (Orange color code). Temperature range +0°F to +150°F/–18°C to +66°C. Not compatible for hot water services over +150°F/+66°C. NOT RECOMMENDED FOR HOT WATER SERVICES.

1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible.

Limit Switches2:Limit switches set for full open at Port A and Port B. Electro mechanical DPDT. Signal voltage: Maximum 2A @ 250VAC. Maximum 2A @ 24VDC. Enclosure rating: IP 67.

2 Supplied standard with pneumatic and hydraulic actuators. Optional with manual operator.

4.0 DIMENSIONS

Series 725S with Manual Gear Operator

KU

90°

H

A

I

B

CJ

ED

Series 725S with Manual Gear Operator

Size Dimensions Weight

Actual Outside Approximate

Nominal Diameter A B C D E H I J U (Each)inches inches inches inches inches inches inches inches inches inches inches lb

DN mm mm mm mm mm mm mm mm mm mm kg4 4.5 19.34 20.26 13.32 16.14 19.10 13.75 8.88 11.43 24.80 505

DN100 114.3 491 515 338 410 485 350 226 290 630 2296 6.625 25.26 24.43 15.89 19.70 22.61 13.75 10.89 14.55 24.80 855

DN150 168.3 642 621 404 501 575 350 277 370 630 3888 8.625 30.50 30.61 19.50 24.20 27.60 16.70 13.96 17.19 24.80 1398

DN200 219.1 775 778 495 615 702 425 355 437 630 634

2

victaulic.com

Page 3: 08.41 Series 725S Diverter Valve Submittal | Victaulic · Series 725S with Manual Gear Operator Series 725S with Pneumatic Actuator Series 725S with Hydraulic Actuator Series 725S

08.41 12808 Rev C Updated 03/2020 © 2020 Victaulic Company. All rights reserved.

victaulic.com

4.1 DIMENSIONS

Series 725S with Pneumatic Actuator

K90°

J

H

A

I

B

C

E

D

K

H

A

I

30°

Series 725S with Pneumatic Actuator – Center Off-Center

Size Dimensions Weight

Actual Outside Center Off-Center Center Off-Center Approximate

Nominal Diameter A B C D E H H I J K K (Each)inches inches inches inches inches inches inches inches inches inches inches inches inches lb

DN mm mm mm mm mm mm mm mm mm mm mm mm kg4 4.5 19.34 20.26 13.32 16.14 25.00 34.00 22.40 8.88 11.43 4.92 27.50 546

DN100 114.3 491 515 338 410 635 864 569.00 226 290 125 698.50 2486 6.625 25.26 24.43 15.89 19.70 28.50 34.00 22.40 10.89 14.55 4.92 27.50 896

DN150 168.3 642 621 404 501 725 864 569.00 277 370 125 698.50 4068 8.625 30.50 30.61 19.50 24.20 33.50 37.00 25.00 13.96 17.19 6.30 29.40 1438

DN200 219.1 775 778 495 615 852 940 635.00 355 437 160 746.80 653

3

victaulic.com

Page 4: 08.41 Series 725S Diverter Valve Submittal | Victaulic · Series 725S with Manual Gear Operator Series 725S with Pneumatic Actuator Series 725S with Hydraulic Actuator Series 725S

08.41 12808 Rev C Updated 03/2020 © 2020 Victaulic Company. All rights reserved.

victaulic.com

4.2 DIMENSIONS

Series 725S with Hydraulic Actuator

K

90°

J

H

A

I

B

C

E

D

K

H

A

I

30°

Series 725S with Hydraulic Actuator – Center Off-Center

Size Dimensions Weight

Actual Outside Center Off-Center Center Off-Center Approximate

Nominal Diameter A B C D E H H I J K K (Each)inches inches inches inches inches inches inches inches inches inches inches inches inches lb

DN mm mm mm mm mm mm mm mm mm mm mm mm kg4 4.5 19.34 20.26 13.32 15.96 25.44 26.13 19.20 8.88 11.43 4.92 21.14 561

DN100 114.3 491 515 338 405 646 664 487.55 226 290 125 537.03 2556 6.625 25.26 24.43 15.89 19.70 29.18 26.13 19.20 10.89 14.55 4.92 21.14 911

DN150 168.3 642 621 404 501 741 664 487.55 277 370 125 537.03 4148 8.625 30.50 30.61 19.50 24.20 34.03 29.12 21.88 13.96 17.19 6.30 23.04 1454

DN200 219.1 775 777.5 495 615 864 740 555.80 355 437 160 585.21 660

4

victaulic.com

Page 5: 08.41 Series 725S Diverter Valve Submittal | Victaulic · Series 725S with Manual Gear Operator Series 725S with Pneumatic Actuator Series 725S with Hydraulic Actuator Series 725S

08.41 12808 Rev C Updated 03/2020 © 2020 Victaulic Company. All rights reserved.

victaulic.com

4.3 DIMENSIONS

Series 725S with Electric Actuator

K L90°

J

H

U

A

I

B

C

E

D

K

H

U

A

I

30°

Series 725S with Electric Actuator – Center Off-Center

Size Dimensions Weight

Nominal

Actual Outside Diameter A B C

D E

Center H

Off-Center H I J

Center K

Off-Center K L U

Approximate (Each)

inches DN

inches mm

inches mm

inches mm

inches mm

inches mm

inches mm

inches mm

inches mm

inches mm

inches mm

inches mm

inches mm

inches mm

inches mm

lb kg

4 4.5 19.34 20.26 13.32 18.89 31.26 27.83 29.50 8.88 11.43 7.56 20.20 11.42 12.50 611DN100 114.3 491 515 338 480 794 707 749.00 226 290 192 513.00 290 315 277

6 6.625 25.26 24.43 15.89 22.60 34.96 27.83 29.50 10.89 14.55 7.56 20.20 11.42 12.50 961DN150 168.3 642 621 404 574 888 707 749.00 277 370 192 513.00 290 315 436

8 8.625 30.50 30.61 19.50 27.60 39.50 30.82 32.20 13.96 17.19 8.90 22.50 11.42 12.50 1504DN200 219.1 775 778 495 702 1003 783 818.00 355 437 227 572.00 290 315 682

5.0 PERFORMANCENOTES

• When used for diverting backfill, abrasive media valve should be flushed after the backfill flow ceases and prior to operating the valve.

• During the water flushing operation, the valve may be operated under pressure.

• In the event a line becomes blocked, the valve may be rotated under pressure to the alternate port in an attempt to clear the line. The valve must be flushed with water thoroughly after each dump event. Depending on operating conditions, the valve may need to be serviced or replaced prior to returning to service.

5.1 PERFORMANCE

Operator/Actuator PerformanceSize Manual (Gear Operator) Pneumatic Hydraulic Electric†

Supply Air Supply Fluid

RPM RPMNominal

inches DN

# Turns from Flow Position A to Flow

Position B

Hand Wheel Dimensions

inches mm

Rim Pull

lbf N

Pressure

psi bar

Flow Rate

SFPM l/s

RPM Pressure

psi bar

Flow Rate

gpm l/s

4 DN100 80 24.80

63051 69

92 6.3

32 15 109 2500

17230

1.84 2000 90

6 DN150 80 24.80

63067 91

92 6.3

42 20 100 2500

17230

1.84 2000 90

8 DN200 109 24.80

63077

10492 6.3

85 40 * 90 § 2500

17230

1.84 2000 90

NOTE: For additional actuation requirements, contact Victaulic.* for Australia only: 61 l/s§ for Australia only: 192 RPM† electrical requirements vary based on voltage

5

victaulic.com

Page 6: 08.41 Series 725S Diverter Valve Submittal | Victaulic · Series 725S with Manual Gear Operator Series 725S with Pneumatic Actuator Series 725S with Hydraulic Actuator Series 725S

08.41 12808 Rev C Updated 03/2020 © 2020 Victaulic Company. All rights reserved.

victaulic.com

User Responsibility for Product Selection and Suitability NoteEach user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications. All productsVictaulic products for a particular end-use application, in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications, and the applicable building codes and related Victaulic reserves the right to change product specifications, designs and standard regulations as well as Victaulic performance, maintenance, safety, and warning equipment without notice and without incurring obligations.instructions. Nothing in this or any other document, nor any verbal recommendation, Installationadvice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale, installation instructions of the product you are installing. Handbooks are included with each shipmentguide, or this disclaimer. of Victaulic products, providing complete installation and assembly data, and are available

Intellectual Property Rights in PDF format on our website at www.victaulic.com.No statement contained herein concerning a possible or suggested use of any material, Warrantyproduct, service, or design is intended, or should be constructed, to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details.under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such Trademarksmaterial, product, service, or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right. The terms “Patented” or “Patent Pending” refer to design or utility patents Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries.or patent applications for articles and/or methods of use in the United States and/or other countries.

6.0 NOTIFICATIONS

WARNING

• Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products.

• Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products.

• Wear safety glasses, hardhat, and foot protection.

Failure to follow these instructions could result in death or serious personal injury and property damage.

7.0 REFERENCE MATERIALS

ClassSize

CodeNominal

SizeOperator/Actuator

Orientation 2 End Prep

V 1 C040 725

Style Actuation Options

1

ManualC – CenterPneumatic, Hydraulic, ElectricC – CenterF – O�-Center

040060080

V 725S4"/DN1006"/DN1508"/DN200

Manual (Gear Operator)M – Hand WheelN – Chain WheelPneumaticP – PneumaticHydraulicH – HydraulicElectric 1

1 – 575V, 50/60 Hz, 3 phase2 – 480V, 50/60Hz, 3 phase3 – 400V, 50/60 Hz, 3 phase4 – 220V, 50/60 Hz, 3 phase5 – 220V, 50/60 Hz, 1 phaseS – Special

1 – OGS/EndSeal Grooved8 – Style 808 Grooved 3

9 – Style 809N Ring

1 Allows for +/– 10% of voltage listed2 Refer to Section 4 of Publication 08.41 for orientation details3 Available in 6"/DN150 and 8"/DN200 only

I-100: Victaulic Field Installation Handbook

I-725S: Victaulic Series 725S Installation and Operating Manual

I-809N: Victaulic Style 809N High-Pressure Coupling for Ring Systems Installation Manual

05.01: Victaulic Seal Selection Guide

25.02: Victaulic EndSeal™ Pipe Groove Specifications

25.04: Victaulic Double Cut Groove Specifications

29.01: Victaulic Terms and Conditions/Warranty

6

victaulic.com