Top Banner
OPERATOR'S MANUAL Model 750, 751, 754, 774, 791, & 794 Soft Serve Freezers Original Operating Instructions 028754- M 2/01/02 (Original Publication) Updated 7/18/14
79
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 0750,751,754,774,791,794op0.pdf

OPERATOR'SMANUAL

Model 750, 751, 754, 774,791, & 794 Soft Serve Freezers

Original Operating Instructions

028754-M2/01/02 (Original Publication)

Updated 7/18/14

Page 2: 0750,751,754,774,791,794op0.pdf

Complete this page for quick reference when service is required:

Taylor Distributor:

Address:

Phone:

Service:

Parts:

Date of Installation:

Information found on the data label:

Model Number:

Serial Number:

Electrical Specs: Voltage Cycle

Phase

Maximum Fuse Size: A

Minimum Wire Ampacity: A

E 2002 Carrier Commercial Refrigeration, Inc.028754-MAny unauthorized reproduction, disclosure, or distribution of copies by any person of any portion of this work maybe a violation of Copyright Law of the United States of America and other countries, could result in the awardingof Statutory Damages of up to $250,000 (17 USC 504) for infringement, and may result in further civil and criminalpenalties. All rights reserved.

Taylor Companya division of Carrier Commercial Refrigeration, Inc.750 N. Blackhawk Blvd.Rockton, IL 61072

Page 3: 0750,751,754,774,791,794op0.pdf

Table of Contents Models 750, 751, 754, 774, 791, 794

Table of Contents

Section 1 To the Installer 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Section 2 To the Operator 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Section 3 Safety 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Section 4 Operator Parts Identification 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Model 750 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Model 751 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Model 754 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Model 774 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Model 774 Topping Pump (053794- ) 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Model 791 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Model 794 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Models 750 & 751 Single Spout Door and Beater Assembly 14. . . . . . . . . . . . . . . .Models 754, 774 & 794 Three Spout Door and Beater Assembly 15. . . . . . . . . . . .Model 791 Three Spout Door and Beater Assembly 16. . . . . . . . . . . . . . . . . . . . . . .Accessories 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Section 5 Important: To the Operator 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Symbol Definitions 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Power Switch 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .MIX LOW Indicator Light 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .MIX REF Key 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .STANDBY Key 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .WASH Key 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .AUTO Key 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Reset Button 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Air Tube 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Adjustable Draw Handle 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Section 6 Operating Procedures 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Prior to Set- Up (Model 774) 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Assembly 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Sanitizing 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Priming 28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Closing Procedure 29. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 4: 0750,751,754,774,791,794op0.pdf

Models 750, 751, 754, 774, 791, 794 Table of Contents

Table of Contents - Page 2

Draining Product From The Freezing Cylinder 29. . . . . . . . . . . . . . . . . . . . . . . . . . . .Rinsing 29. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cleaning 29. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Disassembly 30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Brush Cleaning 30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Section 7 Important: Operator Checklist 31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .During Cleaning and Sanitizing 31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Troubleshooting Bacterial Count 31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Regular Maintenance Checks 31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Winter Storage 32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Section 8 Troubleshooting Guide 33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Section 9 Parts Replacement Schedule 36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Section 10 Limited Warranty on Equipment 37. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Section 11 Limited Warranty on Parts 39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Section 12 Parts List 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Wiring Diagrams 66. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Note: Continuing research results in steady improvements; therefore, informationin this manual is subject to change without notice.

Note: Only instructions originating from the factory or its authorized translationrepresentative(s) are considered to be the original set of instructions.

E 2002 Carrier Commercial Refrigeration, Inc. (Original Publication)(Updated July, 2014)All rights reserved.028754-M

Any unauthorized reproduction, disclosure, or distribution of copies by any person of any portion of this workmay be a violation of Copyright Law of the United States of America and other countries, could result in theawarding of Statutory Damages of up to $250,000 (17 USC 504) for infringement, and may result in furthercivil and criminal penalties. All rights reserved.

Taylor Companya division of Carrier Commercial Refrigeration, Inc.750 N. Blackhawk Blvd.Rockton, IL 61072

Page 5: 0750,751,754,774,791,794op0.pdf

1Models 750, 751, 754, 774, 791, 794 To the Installer

131206

Section 1 To the Installer

The following information has been included in themanual as safety and regulatory guidelines. Forcomplete installation instructions, please see theInstallation Checklist.

Installer Safety

In all areas of the world, equipment should beinstalled in accordance with existing local codes.Please contact your local authorities if you have anyquestions.

Care should be taken to ensure that all basic safetypractices are followed during the installation andservicing activities related to the installation andservice of Taylor equipment.

S Only authorized Taylor service personnelshould perform installation and repairs on theequipment.

S Authorized service personnel should consultOSHA Standard 29CFRI910.147 or theapplicable code of the local area for theindustry standards on lockout/tagoutprocedures before beginning any installationor repairs.

S Authorized service personnel must ensurethat the proper PPE is available and wornwhen required during installation and service.

S Authorized service personnelmust remove allmetal jewelry, rings, and watches beforeworking on electrical equipment.

The main power supply(ies) to the freezermust be disconnected prior to performing any repairs.Failure to follow this instruction may result in personalinjury or death from electrical shock or hazardousmoving parts as well as poor performance or damageto the equipment.

Note: All repairs must be performed by anauthorized Taylor Service Technician.

This unit has many sharp edges that cancause severe injuries.

Site Preparation

Review the area the unit is to be installed in beforeuncrating the unit making sure that all possiblehazards the user or equipment may come into havebeen addressed.

Air Cooled Units

DO NOT obstruct air intake and discharge openings:

Counter Model: 6” (152 mm) minimum air space onboth sides and 0” on the rear.Console Models: 3” (76 mm) minimum air space onall sides.

This will allow for adequate air flow across thecondenser(s). Failure to allowadequate clearance canreduce the refrigeration capacity of the freezer andpossibly causepermanent damage to the compressor.

For Indoor UseOnly: This unit is designed to operateindoors, under normal ambient temperatures of70_-75_F (21_-24_C). The freezer has successfullyperformed in high ambient temperatures of104_(40_C) at reduced capacities.

This unit must NOT be installed in an areawhere a water jet or hose can be used. NEVER use awater jet or hose to rinse or clean the unit. Failure tofollow this instruction may result in electrocution.

This unit must be installed on a level surfaceto avoid the hazard of tipping. Extreme care should betaken in moving this equipment for any reason. Two ormore persons are required to safely move this unit.Failure to comply may result in personal injury orequipment damage.

Uncrate the unit and inspect it for damage. Report anydamage to your Taylor Distributor.

This piece of equipment is made in the USA and hasUSA sizes of hardware. All metric conversions areapproximate and vary in size.

Page 6: 0750,751,754,774,791,794op0.pdf

2 Models 750, 751, 754, 774, 791, 794To the Installer

101027

Water Connections(Water Cooled Units Only)

An adequate cold water supply must be provided witha hand shut- off valve. On the underside rear of thebase pan, two 3/8” I.P.S. (for single- head units) or two1/2” I.P.S. (for double- head units) water connectionsfor inlet and outlet have been provided for easyhook- up. 1/2” inside diameter water lines should beconnected to the machine. (Flexible lines arerecommended, if local codes permit.) Depending onlocal water conditions, it may be advisable to install awater strainer to prevent foreign substances fromclogging the automatic water valve. There will be onlyone water “in” and one water “out” connection for bothsingle- head and double- head units. DO NOT install ahand shut- off valve on the water “out” line! Watershould always flow in this order: first, through theautomatic water valve; second, through thecondenser; and third, through the outlet fitting to anopen trap drain.

A back flow prevention device is requiredon the incoming water connection side. Pleaserefer to the applicable National, State, and local codesfor determining the proper configuration.

Electrical Connections

In the United States, this equipment is intended to beinstalled in accordance with the National ElectricalCode (NEC), ANSI/NFPA70-1987. Thepurpose of theNEC code is the practical safeguardingof persons andproperty from hazards arising from the use ofelectricity. This code contains provisions considerednecessary for safety. In all other areas of the world,equipment should be installed in accordance with theexisting local codes. Please contact your localauthorities.

FOLLOW YOUR LOCAL ELECTRICAL CODES!

Each unit requires one power supply for each datalabel on the unit. Check the data label(s) on the freezerfor branch circuit overcurrent protection or fuse, circuitampacity, and other electrical specifications. Refer tothe wiring diagram provided inside of the electrical boxfor proper power connections.

CAUTION: THIS EQUIPMENT MUST BEPROPERLY GROUNDED! FAILURE TO DO SOCAN RESULT IN SEVERE PERSONAL INJURYFROM ELECTRICAL SHOCK!

DONOT operate this freezer with larger fusesthan specified on the unit data label. Failure to followthis instruction may result in electrocution or damageto the machine.

This unit is provided with an equipotentialgrounding lug that is to be properly attached to the rearof the frameby the authorized installer. The installationlocation is marked by the equipotential bondingsymbol (5021 of IEC 60417-1) on both the removablepanel and the equipment’s frame.

Stationary appliances which are not equippedwith a power cord and a plug or another device todisconnect the appliance from the power source musthave an all-pole disconnecting device with a contactgap of at least 3 mm installed in the externalinstallation.

Appliances that are permanently connected tofixed wiring and for which leakage currents mayexceed 10 mA, particularly when disconnected or notused for long periods, or during initial installation, shallhave protective devices such as a GFI, to protectagainst the leakage of current, installed by theauthorized personnel to the local codes.

Page 7: 0750,751,754,774,791,794op0.pdf

3Models 750, 751, 754, 774, 791, 794 To the Installer

130819

Supply cords used with this unit shall beoil-resistant, sheathed flexible cable not lighter thanordinary polychloroprene or other equivalent syntheticelastomer-sheathed cord (Code designation 60245IEC 57) installed with the proper cord anchorage torelieve conductors from strain, including twisting, atthe terminals and protect the insulation of theconductors from abrasion.

If the supply cord is damaged, it must be replaced byan authorized Taylor service technician in order toavoid a hazard.

Beater Rotation

Beater rotation must be clockwise as viewedlooking into the freezing cylinder.

Note: The following procedures should beperformed by a trained service technician.

To correct the rotation on a three- phase unit,interchange any two incoming power supply lines atfreezer main terminal block only.

To correct rotation on a single- phase unit, change theleads inside the beater motor. (Follow the diagramprinted on the motor.)

Electrical connections are made directly to theterminal block provided in themain control box locatedunder the upper left side panel on the countertop unit,or behind the service panel on the console units.

Refrigerant

In consideration of our environment, Tayloruses only earth friendly HFC refrigerants. The HFCrefrigerant used in this unit is R404A. This refrigerantis generally considered non-toxic and non-flammable,with an Ozone Depleting Potential (ODP) of zero (0).

However, any gas under pressure is potentiallyhazardous andmust be handled with caution. NEVERfill any refrigerant cylinder completely with liquid.Filling the cylinder to approximately 80% will allow fornormal expansion.

Use only R404A refrigerant that conforms tothe AHRI standard 700 specification. The use of anyother refrigerant may expose users and operators tounexpected safety hazards.

Refrigerant liquid sprayed onto the skin maycause serious damage to tissue. Keep eyes and skinprotected. If refrigerant burns should occur, flushimmediately with cold water. If burns are severe, applyice packs and contact a physician immediately.

Taylor reminds technicians to be cautious ofgovernment laws regarding refrigerant recovery,recycling, and reclaiming systems. If you have anyquestions regarding these laws, please contact thefactory Service Department.

WARNING: R404A refrigerant used inconjunction with polyolester oils is extremely moistureabsorbent. When opening a refrigeration system, themaximum time the system is openmust not exceed 15minutes. Cap all open tubing to prevent humid air orwater from being absorbed by the oil.

Page 8: 0750,751,754,774,791,794op0.pdf

4 Models 750, 751, 754, 774, 791, 794To the Operator

131206

Section 2 To the Operator

The freezer you have purchased has been carefullyengineered andmanufactured to give you dependableoperation. The Taylor soft- serve models covered inthis manual consist of the following: 750, 751, 754,774, 791, and 794.

Theseunits, whenproperly operatedand cared for, willproduce a consistent quality product. Like allmechanical products, they will require cleaning andmaintenance. A minimum amount of care andattention is necessary if the operating proceduresoutlined in this manual are followed closely.

This Operator’s Manual should be readbefore operating or performing any maintenance onyour equipment.

Your freezer will NOT eventually compensate andcorrect for any errors during the set- up or fillingoperations. Thus, the initial assembly and primingprocedures are of extreme importance. It is stronglyrecommended that all personnel responsible for theequipment’s operation study these procedurestogether in order to be properly trained and to makesure that no misunderstandings exist.

In the event you should require technical assistance,please contact your local authorized TaylorDistributor.

Note: Your Taylor warranty is valid only if the parts areauthorized Taylor parts, purchased from the localauthorized Taylor Distributor, and only if all requiredservice work is provided by an authorized Taylorservice technician. Taylor reserves the right to denywarranty claims on units or parts if non- Taylorapproved parts or incorrect refrigerant were installedin the unit, system modifications were performedbeyond factory recommendations, or it is determinedthat the failure was caused by abuse, misuse, neglect,or failure to follow all operating instructions. For fulldetails of your Taylor Warranty, please see the LimitedWarranty section in this manual.

Note: Constant research results in steadyimprovements; therefore, information in thismanual is subject to change without notice.

If the crossed out wheeled bin symbol isaffixed to this product, it signifies that this product is

compliant with the EUDirective as well as other similarlegislation in effect after August 13, 2005. Therefore,it must be collected separately after its use iscompleted, and cannot be disposed as unsortedmunicipal waste. The user is responsible for returningthe product to the appropriate collection facility, asspecified by your local code.

For additional information regarding applicable locallaws, please contact the municipal facility and/or localdistributor.

Compressor Warranty Disclaimer

The refrigeration compressor(s) on this unit arewarranted for the term stated in the Limited Warrantysection in this manual. However, due to the MontrealProtocol and the U.S. Clean Air Act Amendments of1990, many new refrigerants are being tested anddeveloped, thus seeking their way into the serviceindustry. Some of these new refrigerants are beingadvertised as drop- in replacements for numerousapplications. It should be noted that in the event ofordinary service to this unit’s refrigeration system,only the refrigerant specified on the affixed datalabel should be used. The unauthorized use ofalternate refrigerants will void your Taylor compressorwarranty. It is the unit owner’s responsibility to makethis fact known to any technician he employs.

It should also be noted that Taylor does not warrant therefrigerant used in its equipment. For example, if therefrigerant is lost during the course of ordinary serviceto this machine, Taylor has no obligation to eithersupply or provide its replacement either at billable orunbillable terms. Taylor does have the obligation torecommend a suitable replacement if the originalrefrigerant is banned, obsoleted, or no longer availableduring the five year warranty of the compressor.

The Taylor Company will continue to monitor theindustry and test new alternates as they are beingdeveloped. Should a new alternate prove, through ourtesting, that it would be accepted as a drop- inreplacement, then the above disclaimer wouldbecome null and void. To find out the current status ofan alternate refrigerant as it relates to yourcompressor warranty, call the local Taylor Distributoror the Taylor Factory. Be prepared to provide theModel/Serial Number of the unit in question.

Page 9: 0750,751,754,774,791,794op0.pdf

5Models 750, 751, 754, 774, 791, 794 Safety

130819

Section 3 Safety

We, at Taylor Company, are concerned about thesafety of the operatorwhen heor she comes in contactwith the freezer and its parts. Taylor has gone toextreme efforts to design and manufacture built- insafety features to protect both you and the servicetechnician. As an example, warning labels have beenattached to the freezer to further point out safetyprecautions to the operator.

IMPORTANT - Failure to adhere to thefollowing safety precautions may result in severepersonal injury or death. Failure to comply withthese warnings may damage the machine and itscomponents. Component damage will result inpart replacement expense and service repairexpense.

DONOT operate the freezer without readingthis Operator Manual. Failure to follow this instructionmay result in equipment damage, poor freezerperformance, health hazards, or personal injury.

This appliance is to be used only by trainedpersonnel. It is not intended for use by children orpeople with reduced physical, sensory, or mentalcapabilities, or lack of experience and knowledge,unless given supervision or instruction concerning theuse of the appliance by a person responsible for theirsafety.

This unit is provided with an equipotentialgrounding lug that is to be properly attached to the rearof the frameby the authorized installer. The installationlocation is marked by the equipotential bondingsymbol (5021 of IEC 60417-1) on both the removablepanel and the equipment’s frame.

DO NOT use a water jet to clean or rinse thefreezer. Failure to follow these instructions may resultin serious electrical shock.

S DO NOT operate the freezer unless it isproperly grounded.

S DO NOT operate the freezer with larger fusesthan specified on the freezer data label.

S All repairs must be performed by anauthorized Taylor service technician.

S Themain power supplies to the machinemustbe disconnected prior to performing anyrepairs.

S CordConnectedUnits: Only Taylor authorizedservice technicians may install a plug on thisunit.

S Stationary appliances which are not equippedwith a power cord anda plugor another deviceto disconnect the appliance from the powersource must have an all-pole disconnectingdevice with a contact gap of at least 3 mminstalled in the external installation.

S Appliances that are permanently connected tofixed wiring and for which leakage currentsmay exceed 10 mA, particularly whendisconnected or not used for long periods, orduring initial installation, shall have protectivedevices such as a GFI, to protect against theleakage of current, installed by the authorizedpersonnel to the local codes.

S Supply cords used with this unit shall beoil-resistant, sheathed flexible cable notlighter than ordinary polychloroprene or otherequivalent synthetic elastomer-sheathed cord(Code designation 60245 IEC 57) installedwith the proper cord anchorage to relieveconductors from strain, including twisting, atthe terminals and protect the insulation of theconductors from abrasion.

If the supply cord is damaged, it must bereplaced by an authorized Taylor servicetechnician in order to avoid a hazard.

Failure to follow these instructions may result inelectrocution. Contact your local authorized TaylorDistributor for service.

Page 10: 0750,751,754,774,791,794op0.pdf

6 Models 750, 751, 754, 774, 791, 794Safety

130819

S DONOT allow untrained personnel to operatethis machine.

S DO NOT put objects or fingers in door spout.S DONOT operate the freezer unless all service

panels and access doors are restrained withscrews.

S DO NOT remove any internal operating parts(example: freezer door, beater, scraperblades, etc.) unless all control switches are inthe OFF position.

Failure to follow these instructions may result incontaminated product or severe personal injury tofingers or hands from hazardous moving parts.

This unit has many sharp edges that cancause severe injuries.

S DO NOT put objects or fingers in the doorspout. This may contaminate the product andcause severe personal injury from bladecontact.

S USE EXTREME CAUTION when removingthe beater asssembly. The scraper blades arevery sharp.

Failure to follow these instructions may result inelectrocution or damage to the machine. Contact yourlocal authorized Taylor Distributor for service.

This freezer must be placed on a levelsurface. Failure to complymay result in personal injuryor equipment damage.

Cleaning and sanitizing schedules aregoverned by your state or local regulatory agenciesand must be followed accordingly. Please refer to thecleaning section of this manual for the properprocedure to clean this unit.

Access to the service area of the unit must berestricted to persons having knowledge and practicalexperience with the unit, in particular as far as safetyand hygiene are concerned.

DO NOT run the unit without product. Failure to followthis instruction can result in damage to the unit.

DO NOT obstruct air intake and discharge openings:Counter Model: 6” (152 mm) minimum air space onboth sides and 0” on the rear.Console Models: 3” (76 mm) minimum air space onall sides.

Failure to follow this instruction may cause poorfreezer performance and damage to the machine.

These freezers are designed to operate indoors, undernormal ambient temperatures of 70_- 75_F(21_- 24_C). The freezers have successfullyperformed in high ambient temperatures of 104_F(40_C) at reduced capacities.

NOISE LEVEL: Airborne noise emission does notexceed 78 dB(A) when measured at a distance of 1.0meter from the surface of the machine and at a heightof 1.6 meters from the floor.

Page 11: 0750,751,754,774,791,794op0.pdf

7Models 750, 751, 754, 774, 791, 794 Operator Parts Identification

101217

Section 4 Operator Parts Identification

Model 750

Item Description Part No.

1 Cover A.- Hopper X38458- SER

2 Gasket- Hopper Cover 038375

3 Tube A.- Feed X29429- 2

4 Panel- Rear 020891

5 Panel- Upper Side Right 042317

6 Pan- Drip 050766

7 Panel- Right Side 050742

8 Shield- Splash 022763

9 Tray- Drip 013690

Item Description Part No.

10 Panel- Side Left 050741

11 Leg- 4” SS w/O- Ring 013458

12 Louver- Side 051192

13 Stud- Nose Cone 022822

14 Panel A.- Front X50754

15 O- Ring- .643 OD x .077 W 018572

16 O- Ring- 3/8 OD x .070 W 016137

17 Orifice 022465- 100

Page 12: 0750,751,754,774,791,794op0.pdf

8 Models 750, 751, 754, 774, 791, 794Operator Parts Identification

111101

Model 751

Item Description Part No.

1 Cover A.- Hopper X38458- SER

2 Gasket- Hopper Cover 038375

3 Tube A.- Feed X29429- 2

4 Panel- Rear 013637

5 Panel- Upper Side Right 028823

6 Pan- Drip 11- 5/8 Long 027503

7 Panel A.- Lower Side Right X24424- SER

8 Shield- Splash 022763

9 Tray- Drip 14- 7/8 x 5- 1/8 013690

10 Panel- Upper Side 024426

11 Panel- Service 047170

Item Description Part No.

12 Caster- Swivel 018794

13 Stud- Nose Cone 022822

14 Panel A.- Side- Lower X39075- SER

15 O- Ring- .643 OD x .077 W 018572

16 O- Ring- 3/8 OD x .070 W 016137

17 Orifice 022465- 100

18 Louver- Side- Top 051191

19 Panel A.- Front X33237

20 Adaptor A.- Caster X18915

21 Caster- 4” Swivel 5/8” Stemw/Brake

034081

Page 13: 0750,751,754,774,791,794op0.pdf

9Models 750, 751, 754, 774, 791, 794 Operator Parts Identification

Model 754

Item Description Part No.

1 Cover A.- Hopper X38458- SER

2 Gasket- Hopper Cover 038474

3 Tube A.- Feed X29429- 2

4 Panel- Rear 053782

5 Panel- Upper Side Right 028823

6 Panel A.- Side Lower Right X46448- SER

7 Panel- Service 046584

8 Shield- Splash 022766

9 Tray- Drip 014533

10 Caster- Swivel 018794

Item Description Part No.

11 Panel- Upper Side Left 028822

12 Stud- Nose Cone 022822

13 Panel A.- Side Lower Left X46447- SER

14 Louver- Side- Top 051191

15 O- Ring- .643 OD x .077 W 018572

16 O- Ring- 3/8 OD x .070 W 016137

17 Orifice 022465- 100

18 Pan- Drip 17- 1/4” Long 027504

19 Panel A.- Front X32956

20 Adaptor A.- Caster X18915

Page 14: 0750,751,754,774,791,794op0.pdf

10 Models 750, 751, 754, 774, 791, 794Operator Parts Identification

140616

Model 774

Item Description Part No.

1 Cover A.- Hopper X38458- SER

2 Gasket- Hopper Cover 20 Qt. 038474

3 Tube A.- Feed X29429- 2

4 Panel- Upper Rear Inactive X42574

5 Louver- Side- Top 051191

6 Panel A.- Side Lower- Right X46448- SER

7 Panel- Service 047077

8 Shield- Splash 022766

9 Tray- Drip 014533

10 Caster- 4” Swivel 5/8 Stem/Brake 034081

11 Panel- Upper Side Left 028822

12 Pan- Drip 17- 1/4” Long 027504

13 Lid with Ladle 1 oz. 036575

Item Description Part No.

14 Pump A.- Syrup- Tan 053794- TAN

15 O- Ring- .643 OD x .077 W 018572

16 Panel A.- Side Lower- Left X46447- SER

17 Jar- Syrup- Plastic Shallow 036573

18 Jar- Syrup- Stainless- Shallow 036574

19 Stud- Nose Cone 022822

20 Caster- 4” Swivel 5/8” Stem 018794

21 Panel- Lower Rear Inactive 053837

22 O- Ring- 3/8 OD x .070 W 016137

23 Orifice 022465- 100

24 Panel A.- Front- Syrup Inactive X42539

25 Adaptor A.- Caster X18915

Page 15: 0750,751,754,774,791,794op0.pdf

11Models 750, 751, 754, 774, 791, 794 Operator Parts Identification

Model 774 Topping Pump (053794- )

ITEM DESCRIPTION PART NO.

1 Knob-Plunger-Tan 032762-TAN

1 Knob-Plunger-Brown 032762-BRN

1 Knob-Plunger-Red 032762-RED

2 O-Ring-9/16 OD x .103 W 016369

3 Nut-Plunger 036577

4 Collar-Gaging 1/2 Ounce 035514

5 Tube-Plunger 032757

6 Insert-Plunger 032758

7 Spring-Plunger 032761

8 Washer-Nylon 032760

9 Plunger 036578

10 Seal Assembly X33057

10a O-Ring-13/16 OD x .103 W 019330

11 Body-Syrup Pump 047934

12 Nut-Spout 036821

13 Lid-Pump 036822

14 Tube-Discharge 050912

15 O-Ring-1-5/16 OD x .103 W 048149

16 O-Ring-1 OD x .103 W 048148

17 Kit-Valve-Captured Ball Shallow 048166-001

Includes:

1 - Body A.-Pump Valve

1 - O-Ring-1-5/16 OD x .103W (048149)

1 - Brush-cleaning (054068)

1 - Instruction Sheet-Installation/Cleaning

Page 16: 0750,751,754,774,791,794op0.pdf

12 Models 750, 751, 754, 774, 791, 794Operator Parts Identification

120613

Model 791

ITEM DESCRIPTION PART NO.

1 PANEL A.- FRONT X41820- SP3

2 STUD- NOSE CONE 068410

3 PANEL- SIDE 069038

4 KIT A.- COVER- HOPPER X68150

5 TUBE A.- FEED- SS- 5/32 X29429- 2

6 PANEL- REAR 041855

ITEM DESCRIPTION PART NO.

7 CASTER- 4” SWV 5/8 STEM 018794

8 CASTER- 4” SWV 5/8 STEMW/BRAKE

034081

9 TRAY- DRIP 16- 7/8L X 5- 1/8 020157

10 SHIELD- SPLASH 022765

11 PAN- DRIP 19- 1/2 LONG 035034

Page 17: 0750,751,754,774,791,794op0.pdf

13Models 750, 751, 754, 774, 791, 794 Operator Parts Identification

130508

Model 794

ITEM DESCRIPTION PART NO.

1 COVER- HOPPER- 14 QT 041682- GRY

2 PAN- DRIP 19 1/2 LONG 035034

3 TUBE A.- FEED X29429- 2

4 PANEL- REAR 041855

5 PANEL- SIDE *LEFT 068691

6 PANEL- SIDE *RIGHT 068692

7 PANEL- SERVICE 064000

8 SHIELD- SPLASH 022765

9 TRAY- DRIP 021057

ITEM DESCRIPTION PART NO.

10 CASTER- 4” SWV 5/8 STEM 018794

11 ADAPTOR A.- CASTER X18915

12 CASTER- 4” SWV 5/8 STEMW/BRAKE

034081

13 STUD- NOSE CONE 022822

14 O- RING- 3/8 OD X .070W 016137

15 O- RING- .643 OD X .077W 018572

16 ORIFICE 022465- 100

17 PANEL A.- FRONT X41820- SP3

Page 18: 0750,751,754,774,791,794op0.pdf

14 Models 750, 751, 754, 774, 791, 794Operator Parts Identification

Models 750 & 751 Single Spout Door and Beater Assembly

ITEM DESCRIPTION PART NO.

1 HANDLE A.- DRAW X55096

1a DRAW HANDLE 028804

1b SCREW-ADJUST 055092

1c O-RING 1/4OD X .070W 015872

1d NUT-JAM 029639-BLK

2 NUT-STUD FLAT LONG 021508

3 DOOR A.- 1-SPOUT X51531-10

4 VALVE A.- DRAW X18303

5 O-RING 7/8OD X .070W 014402

6 CAP-DESIGN 014218

ITEM DESCRIPTION PART NO.

7 O-RING 5/16OD X .070W 016272

8 PLUG-PRIME 028805

9 O-RING-PRIME PLUG 016137

10 PIN A.- PIVOT X22820

11 GASKET-DOOR HT 4” 048926

12 BLADE- SCRAPER 035174

13 BEATER A.- HELICORE X31761

14 BEARING-FRONT 050216

15 SHAFT-BEATER 032564

16 SEAL-DRIVE SHAFT 032560

Page 19: 0750,751,754,774,791,794op0.pdf

15Models 750, 751, 754, 774, 791, 794 Operator Parts Identification

Models 754, 774 & 794 Three Spout Door and Beater Assembly

Item Description Part No.

1 Handle A.- Draw X55096

1a Draw Handle 028804

1b Screw- Adjustment 055092

1c O- Ring 1/4 OD x .070 W 015872

1d Nut- Jam 029639- BLK

2 Nut- Stud Long 034382

3 Nut- Stud Short 034383

4 Valve A.- Draw X18303

5 O- Ring 7/8 OD x .070 W 014402

6 Shaft- Beater 032564

Item Description Part No.

7 Seal- Drive Shaft 032560

8 Cap- Design 014218

9 Decal- Door 021521

10 Door A.- 3 Spout X51532- 12

11 Rod A.- Pivot X20683

12 O- Ring 5/16 OD x .070 W 016272

13 Gasket- Door HT 4” 048926

14 Bearing- Front 050216

15 Beater A.- Helicore X31761

16 Blade- Scraper 035174

Page 20: 0750,751,754,774,791,794op0.pdf

16 Models 750, 751, 754, 774, 791, 794Operator Parts Identification

120124

Model 791 Three Spout Door and Beater Assembly

ITEM DESCRIPTION PART NO.

1 HANDLE A.- DRAW X55096

1a DRAW HANDLE 028804

1b SCREW- ADJUST 055092

1c O- RING 1/4OD X .070W 015872

1d NUT- JAM 029639- BLK

2 PLUG- PRIME 028805

3 ROD A.- PIVOT X22388

4 NUT- STUD LONG 034382

5 NUT- STUD SHORT 034383

6 VALVE A.- DRAW X69539

7 O- RING 7/8OD X .070W 014402

ITEM DESCRIPTION PART NO.

8 CAP- DESIGN 014218

9 DECAL- DOOR 021521

10 DOOR A.- 3- SPOUT X49461- 4

11 ROD A.- PIVOT X22387

12 O- RING 5/16OD X .070W 016272

13 GASKET- DOOR HT 4” 048926

14 BEARING- FRONT 050216

15 BEATER A.- HELICORE X31761

16 BLADE- SCRAPER 035174

17 SHAFT- BEATER 032564

18 SEAL- DRIVE SHAFT 032560

Page 21: 0750,751,754,774,791,794op0.pdf

17Models 750, 751, 754, 774, 791, 794 Operator Parts Identification

140718

Accessories

Item Description Part No.

1 Tool- O- Ring Removal 048260-WHT

2 Brush- Rear Bearing 1” D x 2”L 013071

3 Brush- Double Ended 013072

4 Brush- Draw Valve 1” x 2” x 17” 013073

5 Brush- Mix Pump Body 3” x 7”White

023316

*6 Sanitizer- Stera Sheen Green See note

Item Description Part No.

7 Pail- 10 Qt.(751, 754, 774, 791, 794)

013163

8 Pail- 6 Qt. (750) 023348

9 Deflector- Blower Exhaust (794) 047912

10 Deflector- Blower Exhaust(751, 754, 774)

046586

**Note: A sample container of sanitizer is sent with theunit. For reorders, order Stera Sheen part no. 055492(100 2 oz. packs) or Kay- 5 part no. 041082 (200 packs).

Page 22: 0750,751,754,774,791,794op0.pdf

18 Models 750, 751, 754, 774, 791, 794Important: To the Operator

Section 5 Important: To the Operator750/751

754/774/791/794

ITEM DESCRIPTION

1 MIX LOW INDICATOR LIGHT2 MIX REFRIGERATION KEY3 STANDBY KEY4 WASH KEY5 AUTO KEY6 POWER ON/OFF (TOGGLE)7 RESET BUTTON

Symbol Definitions

To better communicate in the International arena, thewords onmany of our operator switchesand keyshavebeen replaced with symbols to indicate their functions.Your Taylor equipment is designed with theseInternational symbols.

Page 23: 0750,751,754,774,791,794op0.pdf

19Models 750, 751, 754, 774, 791, 794 Important: To the Operator

130819

The following chart identifies the symbol definitions.

= OFF

= ON

= MIX

= STANDBY

= WASH

= AUTO

Power Switch

When placed in the ON position, the power switchallows SOFTECH control panel operation.

MIX LOW Indicator Light

Located on the front of the machine is a mix levelindicating light. When the light is flashing, it indicatesthat themix hopper has a low supply of mix and shouldbe refilled as soon as possible. Always maintain atleast 3” (7.6 cm) of mix in the hopper. If you neglect toadd mix, a freeze- up may occur. This will causeeventual damage to the beater, blades, drive shaft,and freezer door.

MIX REF Key

When the MIX REF key is pressed, the light comes onindicating the mix hopper refrigeration system isoperating. For the Models 754, 774, 791, and 794 theMIX REF is controlled by the left side of the freezer asviewed from the operator end. The MIX REF functioncannot be cancelled unless the AUTO or STANDBYmodes are cancelled first.

STANDBY Key

The Separate Hopper Refrigeration System (SHR)and the Cylinder Temperature Retention System(CTR) are standard features on these machines. TheSHR incorporates the use of a separate smallrefrigeration system to maintain the mix in the hopperbelow 40_(4.4_C) to assure bacteria control. TheCTRworks with theSHR tomaintain agood quality product.

During long “No Sale” periods, it is necessary to warmthe product in the freezing cylinder to approximately35_F to 40_F (1.7_C to 4.4_C) to prevent overbeatingand product breakdown.

To activate the SHR and CTR, press the STANDBYkey. Remove the air orifice and place the air tube (endwithout the hole) into the mix inlet hole.

IMPORTANT: Make sure the level of mix in thehopper is below the mix delivery hole in the feedtube. Failure to follow this instruction may result inlower product quality when normal operation isresumed.

When the STANDBY key is pressed, the light comeson, indicating the CTR (Cylinder TemperatureRetention System) has been activated. In theSTANDBY mode, the WASH and AUTO functions areautomatically cancelled. The MIX REF function isautomatically locked in to maintain the mix in thehopper.

To resume normal operation, press the AUTO key.When the unit cycles off, the product in the freezingcylinder will be at serving viscosity. At this time, placethe air tube (end with the hole) into the mix inlet holeand install the air orifice.

WASH Key

When the WASH key is pressed, the light comes on.This indicates beater motor operation. The STANDBYor AUTOmodes must be cancelled first to activate theWASH mode.

AUTO Key

When the AUTO key is pressed, the light comes on.This indicates that the main refrigeration system hasbeen activated. In the AUTO mode, the WASH orSTANDBY functions are automatically cancelled. TheMIX REF function is automatically locked in tomaintain the mix in the mix hopper.

Note: An indicating light and an audible tone willsound whenever a mode of operation has beenpressed. To cancel any function, press the key again.The light and mode of operation will shut off.

Page 24: 0750,751,754,774,791,794op0.pdf

20 Models 750, 751, 754, 774, 791, 794Important: To the Operator

130819

Reset Button

On counter models, the reset button is located on theside of the unit. On console models, the reset buttonis located in the service panel. The reset protects thebeatermotor fromanoverload condition. If anoverloadoccurs, the reset mechanismwill trip. To properly resetthe freezer, press the AUTO key to cancel the cycle.Turn the power switch to the OFF position. Press thereset button firmly.

Donot usemetal objects to press the resetbutton. Failure to follow this instruction mayresult in electrocution.

Turn the power switch to the ON position. Press theWASH key and observe the freezer’s performance.Open the side access panel. Make sure the beatermotor is turning the drive shaft in a clockwise direction(from the operator end) without binding.

If the beatermotor is turning properly, press theWASHkey to cancel the cycle. Press theAUTOkey to resumenormal operation. If the freezer shuts down again,contact a service technician. (For Models 754, 774,791, and 794 press the AUTO key on both sides of theunit to resume normal operation.)

Air Tube

The air tube serves two purposes. One end of the tubehas a hole and the other end does not.

Figure 1

1. After priming the machine, lubricate the o- ringson the air tube (the end with the hole) andplace it into the mix inlet hole. Every time the

draw handle is raised, new mix and air from thehopper will flow down into the freezing cylinder.This will keep the freezing cylinder properlyloaded and will maintain overrun.

2. During long “No Sale” periods, remove the airorifice. Lubricate the o- rings on the air tube(the end without the hole), and place it intothe mix inlet hole. This will prevent any mixfrom entering the freezing cylinder.

IMPORTANT: Make sure the level ofmix in thehopper is below the mix delivery hole in thefeed tube. Failure to follow this instruction mayresult in lower product quality when normaloperation is resumed.

The air orifice is used to meter a certain amountof air into the freezing cylinder. The air orificemaintains overrunandallows enoughmix to enterthe freezing cylinder after a draw.

Adjustable Draw Handle

These units feature an adjustable draw handle toprovide the best portion control. The draw handleshould be adjusted to provide a flow rate of 5 to 7- 1/2oz. (148 to 222 ml) of product per 10 seconds. ToINCREASE the flow rate, turn the screwCOUNTERCLOCKWISE. Turn the screwCLOCKWISE to DECREASE the flow rate. During“Sanitizing” and “Rinsing”, the flow rate can beincreased by removing the pivot pin and placing therestrictive bar on the TOP. When drawing product,always place the restrictive bar on the bottom.

IMPORTANT!When dispensing product, pull onlyone draw handle at a time.

Figure 2

Note: Once the draw rate is set, tighten the lock nutwith a wrench.

Page 25: 0750,751,754,774,791,794op0.pdf

21Models 750, 751, 754, 774, 791, 794 Operating Procedures

080602

Section 6 Operating Procedures

The Model 751 has been selected to illustrate thestep- by- step operating procedures for all modelscontained in this manual. These models, for allpractical purposes of operation, are the same.

Each unit stores mix in a hopper. The mix then flowsby gravity through an air tube down into the freezingcylinder. They all have 3.4 quart (3.2 liter) capacityfreezing cylinders. TheModels 750, 751, 754, and 774have20quart (18.9 liter)mix hoppers. TheModels 791and 794 have 14 quart (13.2 liter) mix hoppers.

Duplicate the following procedures, where they apply,for the second freezing cylinder on Models 754, 774,791, and 794.

We begin our instructions at the point where we enterthe store in the morning and find the partsdisassembled and laid out to air dry from the previousnight’s cleaning.

These opening procedures will show you how toassemble these parts into the freezer, sanitize them,and prime the freezer with fresh mix in preparation toserve your first portion.

If you are disassembling the machine for the first timeor need information to get to this starting point in ourinstructions, turn to page 30, “Disassembly”, and startthere.

Prior to Set-Up (Model 774)

Step 1Remove the two stainless syrup jars with toppingpumps from the syrup rail. Check the water level in theheated syrup toppingwell. Make sure thewater is filledto the indicating mark on the bottom of the well. Theheated rail should have 32 oz. (946.2 ml) of water.

Step 2Place the heater switch in the ON position.

Note: This heating process will take approximately2- 1/2 hours to reach temperature. The water level inthe topping wells must be checked at least once daily.

Step 3Prepareapail of anapproved100PPMsanitizing solu-tion (examples: 2- 1/2 gal. [9.5 liters] of Kay- 5R or2 gal. [7.6 liters] of Stera- SheenR). USE WARMWA-TER AND FOLLOW THE MANUFACTURER’S SPE-CIFICATIONS. Sanitize the topping pumps by placingthe entire pump assembly in the pail of sanitizing solu-tion. Pump the solution through the assembly to thor-oughly sanitize the pump.

Step 4Remove the two topping pumps. Fill each stainlesssyrup jar with topping. Replace the topping pumps inthe syrup jars.

Assembly

Note: When lubricating parts, use an approved foodgrade lubricant (example: Taylor Lube).

MAKE SURE POWER SWITCH IS IN THE“OFF” POSITION! Failure to follow this instructionmay result in severe personal injury from hazardousmoving parts.

Step 1Lubricate the groove and shaft portion that comes incontact with thebearingon thebeater drive shaft. Slidethe seal over the shaft and groove until it snaps intoplace.DONOT lubricate the hex end of the drive shaft.Fill the inside portion of the seal with 1/4” morelubricant and lubricate the flat side of the seal that fitsonto the rear shell bearing.

Figure 3

Page 26: 0750,751,754,774,791,794op0.pdf

22 Models 750, 751, 754, 774, 791, 794Operating Procedures

Insert the drive shaft into the freezing cylinder, hex endfirst, and into the rear shell bearing until the seal fitssecurely over the rear shell bearing. Engage the hexend firmly into the drive coupling. Be sure the driveshaft fits into the drive coupling without binding.

Figure 4

Step 2Take one of the scraper blades and slip it under thehook at the front of the beater. Wrap the blade aroundthe beater following the helix and pushing the bladedown onto the helix as youwrap. At the back end of thebeater, slip the blade under the hook. Repeat thisstep for the second scraper blade.

Figure 5

Holding the beater securely, slide the beater one thirdof the way into the freezing cylinder. Looking into thefreezing cylinder, align thehole at the rear of thebeaterwith the flats on the end of the drive shaft.

Figure 6

Slide the beater the remainder of the way into thefreezing cylinder and over the end of the drive shaft.The beater should fit snugly, but not so tightly that thebeater cannot be turned slightly to engage the driveshaft. If the beater slides in too easily with little or noresistance, there will not be enough force against thebeater to hold the blades in place. If this is the case,contact your authorized Taylor service technician.

Repeat steps 1 and 2 for the other side of the freezeron Models 754, 774, 791, and 794.

Step 3Place the large rubber gasket(s) into the groove(s) onthe back side of the freezer door.

Slide the white plastic front bearing(s) over the bafflerod(s) onto the bearing hub(s) making certain that theflangedendof thebearing is resting against the freezerdoor.

Note: Do not lubricate the gasket(s) or the frontbearing(s).

Figure 7

Page 27: 0750,751,754,774,791,794op0.pdf

23Models 750, 751, 754, 774, 791, 794 Operating Procedures

Note: There are two gaskets and two front bearingsfor the Models 754, 774, 791, and 794 door, one foreach freezing cylinder.

Figure 8

Slide the two o- rings into the grooves on the primeplug(s). Apply an even coat of Taylor Lube to theo- rings and shaft(s).

Figure 9

Note: There are two prime plugs for the Models 754,774, 791, and 794 door, one for each freezing cylinder.

Insert the prime plug(s) into the hole(s) in the top of thefreezer door, and push down.

Figure 10

Step 4Insert the baffle rod(s) through the opening in thebeater(s) and seat the door flush with the freezingcylinder. With the door seated on the freezer studs,install the handscrews. Tighten equally in a crisscrosspattern to insure the door is snug.

Figure 11

Note: On the Models 754, 774, 791, and 794, theshort handscrews go on the bottom and the longhandscrews go on the top.

Page 28: 0750,751,754,774,791,794op0.pdf

24 Models 750, 751, 754, 774, 791, 794Operating Procedures

101109

Step 5Install the draw valve(s). Slide the two o- rings into thegrooves on the draw valve(s), and lubricate.

Figure 12

Note: Models 754, 774, 791, and794have threedrawvalves.

Lubricate the inside of the freezer door spout(s), topand bottom, and insert the draw valve(s) from thebottom until the slot in the draw valve(s) comes intoview.

Figure 13

Step 6Install the adjustable draw handle(s). Slide the o- ringinto the groove on the pivot pin, and lubricate.

Figure 14

Slide the fork over the bar in the slot of the draw valve.Secure with pivot pin.

Figure 15

Note: Models 754, 774, 791, and794have threedrawhandles. Slide the fork of the draw handle in the slot ofthe draw valve, starting from the right. Slide the pivotpin through each draw handle as you insert them intothe draw valves.

Note: These units feature adjustable draw handles toprovide the best portion control. The draw handles canbe adjusted for different flow rates. See page 20 formore information on adjusting these handles.

Page 29: 0750,751,754,774,791,794op0.pdf

25Models 750, 751, 754, 774, 791, 794 Operating Procedures

Step 7Snap the design cap(s) over the end of the doorspout(s).

Figure 16

Step 8Install the front drip tray and the splash shield underthe door spout(s).

Figure 17

Step 9Slide the rear drip pan(s) into thehole in the sidepanel.

Figure 18

Models791&794: Slide the rear drip pan into theholein the front panel.

Step 10Slide two o- rings on one end of the air tube. Slide twoo- rings on the other end of the air tube.

Figure 19

Slide the small o- ring into the groove of the air orifice.Do not lubricate the o- ring.

Figure 20

Note: Make sure the hole in the air orifice is clean andis not clogged. If the hole in the air orifice shouldbecome clogged, use soap and hot water to clear thehole. Do not enlarge the hole in the air orifice.

Page 30: 0750,751,754,774,791,794op0.pdf

26 Models 750, 751, 754, 774, 791, 794Operating Procedures

130118

Install the air orifice into the hole in the top of the airtube (in the end without the small hole on the side).

Figure 21

Step 11Lay the air tube (with the air orifice installed) and thehopper gasket in the bottom of the mix hopper forsanitizing.

Note: The Models 754 and 774 have one hoppergasket for each mix hopper. The Models 791 and 794do not require a hopper gasket.

Repeat steps 10 and 11 for the other side of thefreezer on Models 754, 774, 791, and 794.

CAUTION: Do not run the machine withoutproduct. Failure to follow this instruction can result indamage to the machine.

Sanitizing

Step 1Prepare an approved 100 PPM sanitizing solution(examples: 2- 1/2 gal. [9.5 liters] of Kay- 5R or 2gal. [7.6 liters] of Stera- SheenR). USE WARM WA-TER AND FOLLOW THE MANUFACTURER’SSPECIFICATIONS.

Step 2Pour the sanitizing solution into the hopper and allowit to flow into the freezing cylinder.

Figure 22

Step 3While the solution is flowing into the freezing cylinder,brush clean the mix hopper. When cleaning thehopper, take particular care in brushing the mix levelsensing probe on the rear wall of the hopper, the mixinlet hole, the air tube, and the hopper gasket.

Figure 23

Figure 24

Page 31: 0750,751,754,774,791,794op0.pdf

27Models 750, 751, 754, 774, 791, 794 Operating Procedures

Figure 25

Step 4Place the power switch in the ON position.

Figure 26

Step 5Press the WASH key. This will cause the sanitizingsolution in the freezing cylinder to agitate. Allow it toagitate for five minutes.

Figure 27

Step 6Place an empty pail beneath the door spout and raisethe prime plug.

Figure 28

Step 7When a steady stream of sanitizing solution is flowingfrom the prime plug opening in the bottom of thefreezer door, lower the draw handle. Draw off all thesanitizing solution.

Figure 29

Note: On the Models 754, 774, 791, and 794,momentarily pull the center draw handle down tosanitize the center door spout.

Step 8Once the sanitizer stops flowing from the door spout,raise the draw handle and press the WASH key,cancelling the beater motor operation.

Note: You have just sanitized the freezer. Be sureyour hands are sanitized before continuing theseinstructions.

Page 32: 0750,751,754,774,791,794op0.pdf

28 Models 750, 751, 754, 774, 791, 794Operating Procedures

Step 9Assemble the hopper gasket around the top edge ofthe mix hopper. Stand the air tube in the corner of thehopper.

Figure 30

Repeat steps 1 through 9 for the other side of thefreezer on Models 754, 774, 791, and 794.

Priming

Step 1With a pail beneath the door spout, lower the drawhandle. Be sure the prime plug is still in the UPposition. Pour two gallons (7.6 liters) of fresh mix intothe mix hopper and allow it to flow into the freezingcylinder. This will force out any remaining sanitizingsolution. When full strength mix is flowing from thedoor spout, raise the draw handle.

Note: Use only fresh mix when priming the freezingcylinder.

Figure 31

Step 2Once a steady stream of mix starts to flow from theprime plug opening in the bottom of the freezer door,push down the prime plug.

Figure 32

Step 3Lubricate the o- rings on the air tube on the end withthe small hole on the side.

Step 4Install the air tube (the end with the hole) with the airorifice installed into themix inlet hole in themix hopper.

Step 5Press the AUTO key. The AUTO light will come onindicating the main refrigeration system is operating.When the unit cycles off, the product will be at servingviscosity.

Note: On Models 751, 754, 774, 791, and 794 theMIX REF light will come on, indicating the mixrefrigeration system is operating to maintain the mix inthe mix hopper.

Figure 33

Step 6Fill the hopper with mix. As the mix level comes incontact with the mix level sensing probe on the rearwall of the hopper, the MIX LOW light will shut off.

Page 33: 0750,751,754,774,791,794op0.pdf

29Models 750, 751, 754, 774, 791, 794 Operating Procedures

140718

Step 7Place the mix hopper cover in position over the mixhopper.

Repeat steps 1 through 7 for the other side of thefreezer on Models 754, 774, 791, and 794.

Closing Procedure

To disassemble your unit, the following items will beneeded:

S Two cleaning pailsS Sanitized stainless steel rerun can with lidS Necessary brushes (provided with freezer)S CleanerS Single service towels

Draining Product From TheFreezing Cylinder

Step 1Press the AUTO key, cancelling compressor andbeater motor operation.

Press the MIX REF key, cancelling the mix hopperrefrigeration system.

Step 2Remove the hopper cover, hopper gasket and air tube.Take these parts to the sink for cleaning.

Step 3If local health codes permit the use of rerun, placea sanitized, NSF approved stainless steel reruncontainer beneath the door spout. Press the WASHkey and lower the draw handle. Drain the remainingproduct from the freezing cylinder and mix hopper.When the flow of product stops, press the WASH keyand raise the draw handle. Place the sanitized lid onthe rerun container and place it in the walk- in cooler.

Note: If local health codesDONOTpermit theuseof rerun, the product must be discarded. Drain theproduct into a pail and properly discard it.

Repeat steps 1 through 3 for the other side of thefreezer on Models 754, 774, 791, and 794.

ALWAYS FOLLOW LOCAL HEALTH CODES.

Rinsing

Step 1Pour twogallons (7.6 liters) of cool cleanwater into themix hopper. With the brushes provided, scrub the mixhopper, mix inlet hole and mix level sensing probe.

Step 2With apail beneath thedoor spout, raise theprimeplugand press the WASH key.

Step 3When a steady stream of rinse water is flowing fromthe prime plug opening in the bottom of the freezerdoor, lower the draw handle. Drain all the rinse waterfrom the freezing cylinder, raise the draw handle andpress the WASH key cancelling the WASH mode.

Repeat steps 1 through 3 for the other side of thefreezer on Models 754, 774, 791, and 794.

Cleaning

Step 1Prepare an approved 100 PPM cleaning solution(examples: 2- 1/2 gal. [9.5 liters] of Kay- 5R or 2gal. [7.6 liters] of Stera- SheenR). USE WARM WA-TER AND FOLLOW THE MANUFACTURER’SSPECIFICATIONS.

Step 2Push down the prime plug. Pour the cleaning solutioninto the mix hopper.

Step 3While the solution is flowing into the freezing cylinder,brush clean the mix hopper, mix level sensing probe,and the mix inlet hole.

Step 4Press the WASH key. This will cause the cleaningsolution in the freezing cylinder to agitate.

Step 5Place an empty pail beneath the door spout and raisethe prime plug.

Page 34: 0750,751,754,774,791,794op0.pdf

30 Models 750, 751, 754, 774, 791, 794Operating Procedures

080324

Step 6When a steady stream of cleaning solution is flowingfrom the prime plug opening in the bottom of thefreezer door, lower the draw handle. Draw off all of thesolution.

Step 7Once the cleaner stops flowing from the door spout,raise the draw handle and press the WASH keycancelling the WASH mode.

Repeat steps 1 through 7 for the other side of thefreezer on Models 754, 774, 791, and 794.

Disassembly

MAKE SURE POWER SWITCH IS IN THE“OFF” POSITION! Failure to follow this instructionmay result in severe personal injury from hazardousmoving parts.

Step 1Remove the handscrews, freezer door(s), beater(s),scraper blades, and drive shaft(s) from the freezingcylinder(s). Take these parts to the sink for cleaning.

Step 2Remove the front drip tray and the splash shield.

Brush Cleaning

Step 1Prepare a sink with an approved cleaning solution (ex-amples: Kay- 5r or Stera- Sheenr). USE WARMWA-TER AND FOLLOW THE MANUFACTURER’S SPE-CIFICATIONS. If another approved cleaner is used,dilute it according to the label instructions. (IMPORT-ANT: Follow the label directions. Too STRONG of asolution can cause parts damage, while too MILD of asolution will not provide adequate cleaning.) Makesure all brushes providedwith the freezer are availablefor brush cleaning.

Step 2Remove the seal(s) from the drive shaft(s).

Step 3From the freezer door(s) remove:

S gasket(s)S front bearing(s)S pivot pin(s)

S adjustable draw handle(s)S design cap(s)S draw valve(s)S prime plug(s)S all o- rings

Note: To remove o- rings, use a single service towelto grasp the o- ring. Apply pressure in an upwarddirection until the o- ring pops out of its groove. Withthe other hand, push the top of the o- ring forward andit will roll out of the groove and can be easily removed.If there is more than one o- ring to be removed, alwaysremove the rear o- ring first. This will allow the o- ringto slide over the forward rings without falling into theopen grooves.

Step 4Remove the o- rings from the air tube(s) and airorifice(s).

Step 5Return to the freezer with a small amount of cleaningsolution. Brush clean the rear shell bearing(s) at theback of the freezing cylinder(s) with the black bristlebrush.

Figure 34

Step 6Remove the rear drip pan(s) and take to the sink forcleaning.

Note: If the drip pan is filled with an excessive amountof mix, refer to the Troubleshooting Guide.

Step 7Thoroughly brush clean all disassembled parts in thecleaning solutionmaking sure all lubricant and mix filmis removed. Take particular care to brush clean thedraw valve core(s) in the freezer door. Place all thecleaned parts on a clean, dry surface to air dryovernight.

Step 8Wipe clean all exterior surfaces of the freezer.

Page 35: 0750,751,754,774,791,794op0.pdf

31Models 750, 751, 754, 774, 791, 794 Important: Operator Checklist

061122

Section 7 Important: Operator Checklist

During Cleaning and Sanitizing

Cleaning and sanitizing schedules are governedby federal, state, or local regulatory agencies,and must be followed accordingly. If the unithas a “Standby mode”, it must not be used inlieu of proper cleaning and sanitizingprocedures and frequencies set forth by theruling health authority. The following checkpoints should be stressed during the cleaningand sanitizing operations.

CLEANING AND SANITIZING MUST BEPERFORMED DAILY.

ALWAYS FOLLOW LOCAL HEALTH CODES.

Troubleshooting Bacterial Count

j 1. Thoroughly clean and sanitize machineregularly, including complete disassembly andbrush cleaning.

j 2. Use all brushes supplied for thorough cleaning.The brushes are specially designed to reach allmix passageways.

j 3. Use the white bristle brush to clean the mix inlethole which extends from the mix hopper downto the rear of the freezing cylinder.

j 4. Use the black bristle brush to thoroughly cleanthe rear shell bearing located at the rear of thefreezing cylinder. Be sure to have a generousamount of cleaning solution on the brush.

j 5. IF LOCAL HEALTH CODES PERMIT THEUSE OF RERUN, make sure the mix rerun isstored in a sanitized, covered stainless steelcontainer and used the following day. DO NOTprime the machine with rerun. When usingrerun, skim off the foam and discard. Mix thererunwith freshmix in a ratio of 50/50 during thedays operation.

j 6. On a designated day of theweek, run themix aslow as feasible and discard it after closing. Thiswill break the rerun cycle and reduce thepossibility of high bacteria and coliform counts.

j 7. Properly prepare the cleaning and sanitizingsolutions. Read and follow label directionscarefully. Too strong of a solution may damagethe parts and too weak of a solution will not doan adequate job of cleaning or sanitizing.

j 8. The temperature of the mix in the mix hopperand walk- in cooler should be below 40_F.(4.4_C.).

Regular Maintenance Checks

j 1. Replace scraper blades that are nicked ordamaged. Before installing the beaterassembly, be certain that scraper blades areproperly attached to the helix.

j 2. Check the rear shell bearing for signs of wear(excessive mix leakage in rear drip pan) and becertain it is properly cleaned.

j 3. Using a screwdriver and cloth towel, keep therear shell bearing and the 3/4 hex drive couplingclean and free of lubricant and mix deposits.

j 4. Dispose of o- rings and seals if they are worn,torn, or fit too loosely, and replace with newones.

j 5. Follow all lubricating procedures as outlined in“Assembly”.

Page 36: 0750,751,754,774,791,794op0.pdf

32 Models 750, 751, 754, 774, 791, 794Important: Operator Checklist

080324

j 6. If your machine is air cooled, check thecondensers for accumulation of dirt and lint.Dirty condensers will reduce the efficiency andcapacity of themachine. Condensers should becleaned monthly with a soft brush. Never usescrewdrivers or other metal probes to cleanbetween the fins.Note: For machines equipped with an air filter,it will be necessary to vacuum clean the filterson a monthly schedule.

Caution: Always disconnectelectrical power prior to cleaning thecondenser. Failure to follow this instructionmay result in electrocution.

j 7. If your machine is equipped with an auxiliaryrefrigeration system, check the auxiliarycondenser for accumulation of dirt and lint. Dirtycondensers will reduce the refrigerationcapacity of the mix hopper. Condensers mustbe cleanedmonthlywith a soft brush. Neverusescrewdrivers or other metal probes to cleanbetween the fins. Failure to follow thisinstruction may result in electrocution.

Caution: Always disconnectelectrical power prior to cleaning thecondenser. Failure to follow this instructionmay result in electrocution.

j 8. If yourmachine iswater cooled, check thewaterlines for kinks or leaks. Kinks can occur whenthe machine is moved back and forth forcleaning or maintenance purposes.Deteriorated or cracked water lines should bereplaced only by an authorized Taylordistributor.

Winter Storage

If the placeof business is to be closedduring thewintermonths, it is important to protect the freezer byfollowing certain precautions, particularly if thebuilding is subject to freezing conditions.

Disconnect the freezer from the main power source toprevent possible electrical damage.

On water cooled freezers, disconnect the watersupply. Relieve pressure on the spring in the watervalve. Use air pressure on the outlet side to blow outany water remaining in the condenser. This isextremely important. Failure to follow this proceduremay cause severe and costly damage to therefrigeration system.

Your local Taylor Distributor can perform this winterstorage service for you.

Wrap detachable parts of the freezer such as beater,blades, drive shaft, and freezer door, and place theminaprotecteddry place. Rubber trimparts andgasketscan be protected by wrapping them withmoisture- proof paper. All parts should be thoroughlycleaned of dried mix or lubrication which attract miceand other vermin.

Page 37: 0750,751,754,774,791,794op0.pdf

33Models 750, 751, 754, 774, 791, 794 Troubleshooting Guide

Section 8 Troubleshooting Guide

PROBLEM PROBABLE CAUSE REMEDY PAGEREF.

1. No product is beingdispensed with draw valveopen and the machine inthe AUTO mode.

a. Freeze- up in mix inlethole.

a. Call service technician toadjust the mix hoppertemperature.

- - -

b. Beater motor out on reset. b. Reset the freezer. 20

c. The beater is rotatingcounterclockwise from theoperator end.

c. Contact service technicianto correct rotation toclockwise from operatorend.

- - -

d. The circuit breaker is offor the fuse is blown.

d. Turn the breaker on, orreplace the fuse.

- - -

e. There is inadequate mix inthe mix hopper.

e. Fill the mix hopper withmix.

28

f. The air orifice is notinstalled.

f. Install air orifice in airtube.

28

2. The product is too stiff. a. The viscosity needsadjustment.

a. Contact servicetechnician.

- - -

b. The air orifice is notinstalled.

b. Install air orifice in airtube.

28

3. The product is too soft. a. Viscosity needsadjustment.

a. Contact servicetechnician.

- - -

b. Not enough air spacearound unit. (Air cooledunits)

b. Allow for adequate air flowacross the condenser.

6

c. Worn scraper blades. c. Replace regularly. 36

d. Dirty condenser (A/C) d. Clean monthly. 32

e. Mix is out of date. e. Use only fresh mix. - - -

f. Loss of water. (W/C) f. Locate cause of waterloss and correct.

32

4. The mix in the mix hopperis too cold.

a. The temperature is out ofadjustment.

a. Call service technician toadjust the mix hoppertemperature.

- - -

Page 38: 0750,751,754,774,791,794op0.pdf

34 Models 750, 751, 754, 774, 791, 794Troubleshooting Guide

PROBLEM PROBABLE CAUSE REMEDY PAGEREF.

5. The mix in the mix hopperis too warm.

a. The temperature is out ofadjustment.

a. Call service technician toadjust the mix hoppertemperature.

- - -

b. Missing or defective mixhopper gasket.

b. Replace/install the gasketaround the mix hopper.

28

c. The mix hopper cover isnot in position.

c. Place the cover inposition.

29

d. The MIX REF light is notlit.

d. Press the MIX REF key. 19

6. The drive shaft is stuck inthe drive coupling.

a. Rounded corners of driveshaft, coupling, or both.

a. Call service technician tocorrect cause, and toreplace the necessarycomponents. Do notlubricate the hex end ofthe drive shaft.

- - -

b. Mix and lubricant collectedin the drive coupling.

b. Brush clean the rear shellbearing area regularly.

30

7. The freezing cylinder wallsare scored.

a. The beater assembly isbent.

a. Call service technician torepair or replace thebeater and to correct thecause of insufficient mixin the freezing cylinder.

- - -

b. The front bearing ismissing or worn on thefreezer door.

b. Install or replace the frontbearing.

22

8. Excessive mix leakageinto the rear drip pan.

a. Missing or worn driveshaft seal on drive shaft.

a. Install or replace regularly. 21 / 36

b. The rear shell bearing isworn.

b. Call service technician toreplace rear shell bearing.

- - -

9. Excessive mix leakagefrom door spout.

a. Missing or worn drawvalve o- rings.

a. Install or replace regularly. 24 / 36

b. Inadequate lubrication ofdraw valve o- rings.

b. Lubricate properly. 24

c. Wrong type of lubricant isbeing used (example:petroleum base lubricant).

c. Use the proper lubricant(example: Taylor Lube).

21

10. No freezer operation afterpressing the AUTO key.

a. Unit is unplugged. a. Plug into wall receptacle. - - -

b. The circuit breaker is offor the fuse is blown.

b. Turn the breaker on, orreplace the fuse.

- - -

c. The beater motor is out onreset.

c. Reset the freezer. 20

Page 39: 0750,751,754,774,791,794op0.pdf

35Models 750, 751, 754, 774, 791, 794 Troubleshooting Guide

PROBLEM PROBABLE CAUSE REMEDY PAGEREF.

11. Product is not feeding intothe freezing cylinder.

a. Inadequate level of mix inthe mix hopper.

a. Fill the mix hopper withmix.

28

b. The mix inlet hole isfrozen up.

b. The mix hoppertemperature needsadjustment. Call servicetechnician.

- - -

c. The air tube is installedincorrectly.

c. Install the air tube in themix inlet hole, using theend with the small hole inthe side.

28

d. The air orifice is notinstalled.

d. Install the air orifice in theair tube.

28

Page 40: 0750,751,754,774,791,794op0.pdf

36 Models 750, 751, 754, 774, 791, 794Parts Replacement Schedule

Section 9 Parts Replacement Schedule

PARTDESCRIPTION EVERY3 MONTHS

EVERY6 MONTHS

ANNUALLY

Drive Shaft Seal X

Scraper Blade X

Freezer Door Gasket X

Front Bearing X

Draw Valve O- Ring X

Pivot Pin O- Ring X

Prime Plug O- Ring X

Air Tube O- Ring X

Air Orifice O- Ring X

White Bristle Brush, 3” x 7” Inspect & Replaceif Necessary

Minimum

White Bristle Brush, 1” x 2” Inspect & Replaceif Necessary

Minimum

Black Bristle Brush, 1” x 2” Inspect & Replaceif Necessary

Minimum

Double- Ended Brush Inspect & Replaceif Necessary

Minimum

Refer to Parts List on page 42 when ordering the above parts.

Page 41: 0750,751,754,774,791,794op0.pdf

37Models 750, 751, 754, 774, 791, 794 Limited Warranty on Equipment

131206

Section 10 Limited Warranty on Equipment

TAYLOR COMPANY LIMITED WARRANTY ON FREEZERS

Taylor Company, a division of Carrier Commercial Refrigeration, Inc. (“Taylor”) is pleased to provide this limitedwarranty on new Taylor-branded freezer equipment available from Taylor to the market generally (the “Product”)to the original purchaser only.

LIMITED WARRANTY

Taylor warrants the Product against failure due to defect in materials or workmanship under normal use andservice as follows. All warranty periods begin on the date of original Product installation. If a part fails due todefect during the applicable warranty period, Taylor, through an authorized Taylor distributor or service agency,will provide a new or re- manufactured part, at Taylor’s option, to replace the failed defective part at no charge forthe part. Except as otherwise stated herein, these are Taylor’s exclusive obligations under this limited warranty fora Product failure. This limited warranty is subject to all provisions, conditions, limitations and exclusions listedbelow and on the reverse (if any) of this document.

Product Part Limited Warranty Period

Soft ServeFrozen YogurtShakesSmoothies

Frozen BeverageBatch Desserts

Insulated shell assembly Five (5) years

Refrigeration compressor(except service valve)

Five (5) years

Beater motors Two (2) years

Beater drive gear Two (2) years

Printed circuit boards andSoftech controls beginningwith serial number H8024200

Two (2) years

Parts not otherwise listed inthis table or excluded below

One (1) year

LIMITED WARRANTY CONDITIONS

1. If the date of original installation of the Product cannot be verified, then the limited warranty period beginsninety (90) days from the date of Product manufacture (as indicated by the Product serial number). Proof ofpurchase may be required at time of service.

2. This limited warranty is valid only if the Product is installed and all required service work on the Product isperformed by an authorized Taylor distributor or service agency, and only if genuine, new Taylor parts areused.

3. Installation, use, care, and maintenance must be normal and in accordance with all instructions contained inthe Taylor Operator’s Manual.

4. Defective parts must be returned to the authorized Taylor distributor or service agency for credit.

5. The use of any refrigerant other than that specified on the Product’s data label will void this limited warranty.

LIMITED WARRANTY EXCEPTIONS

This limited warranty does not cover:

1. Labor or other costs incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling ofdefective parts, replacement parts, or new Products.

2. Normal maintenance, cleaning and lubrication as outlined in the Taylor Operator’s Manual, including cleaningof condensers.

Page 42: 0750,751,754,774,791,794op0.pdf

38 Models 750, 751, 754, 774, 791, 794Limited Warranty on Equipment

3. Replacement of wear items designated as Class “000” parts in the Taylor Operator’s Manual.

4. External hoses, electrical power supplies, and machine grounding.

5. Parts not supplied or designated by Taylor, or damages resulting from their use.

6. Return trips or waiting time required because a service technician is prevented from beginning warrantyservice work promptly upon arrival.

7. Failure, damage or repairs due to faulty installation, misapplication, abuse, no or improper servicing,unauthorized alteration or improper operation or use as indicated in the Taylor Operator’s Manual, includingbut not limited to the failure to use proper assembly and cleaning techniques, tools, or approved cleaningsupplies.

8. Failure, damage or repairs due to theft, vandalism, wind, rain, flood, high water, water, lightning, earthquakeor any other natural disaster, fire, corrosive environments, insect or rodent infestation, or other casualty,accident or condition beyond the reasonable control of Taylor; operation above or below the electrical orwater supply specification of the Product; or components repaired or altered in any way so as, in thejudgment of the Manufacturer, to adversely affect performance, or normal wear or deterioration.

9. Any Product purchased over the Internet.

10. Failure to start due to voltage conditions, blown fuses, open circuit breakers, or damages due to theinadequacy or interruption of electrical service.

11. Electricity or fuel costs, or increases in electricity or fuel costs from any reason whatsoever.

12. Damages resulting from the use of any refrigerant other than that specified on the Product’s data label willvoid this limited warranty.

13. Any cost to replace, refill or dispose of refrigerant, including the cost of refrigerant.

14. ANY SPECIAL, INDIRECT OR CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGE OF ANYNATURE WHATSOEVER. Some jurisdictions do not allow the exclusion of incidental or consequentialdamages, so this limitation may not apply to you.

This limited warranty gives you specific legal rights, and you may also have other rights which vary fromjurisdiction to jurisdiction.

LIMITATION OF WARRANTY

THIS LIMITED WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, CONDITIONSAND/OR REMEDIES UNDER THE LAW, INCLUDING ANY IMPLIED WARRANTIES OR CONDITIONS OFMERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THE ORIGINAL OWNER’S SOLEREMEDY WITH RESPECT TO ANY PRODUCTS SHALL BE REPAIR OR REPLACEMENT OF DEFECTIVECOMPONENTS UNDER THE TERMS OF THIS LIMITED WARRANTY. ALL RIGHTS TO CONSEQUENTIALOR INCIDENTAL DAMAGES (INCLUDING CLAIMS FOR LOST SALES, LOST PROFITS, PRODUCT LOSS,PROPERTY DAMAGES OR SERVICE EXPENSES) ARE EXPRESSLY EXCLUDED. THE EXPRESSWARRANTIES MADE IN THIS LIMITED WARRANTY MAY NOT BE ALTERED, ENLARGED, OR CHANGEDBY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON, WHATSOEVER.

LEGAL REMEDIES

The owner must notify Taylor in writing, by certified or registered letter to the following address, of any defect orcomplaint with the Product, stating the defect or complaint and a specific request for repair, replacement, or othercorrection of the Product under warranty, mailed at least thirty (30) days before pursuing any legal rights orremedies.

Taylor Companya division of Carrier Commercial Refrigeration, Inc.

750 N. Blackhawk Blvd.Rockton, IL 61072, U.S.A.

Page 43: 0750,751,754,774,791,794op0.pdf

39Models 750, 751, 754, 774, 791, 794 Limited Warranty on Parts

131206

Section 11 Limited Warranty on Parts

TAYLOR COMPANY LIMITED WARRANTY ON TAYLOR GENUINE PARTS

Taylor Company, a division of Carrier Commercial Refrigeration, Inc. (“Taylor”) is pleased to provide this limitedwarranty on new Taylor genuine replacement components and parts available from Taylor to the market generally(the “Parts”) to the original purchaser only.

LIMITED WARRANTY

Taylor warrants the Parts against failure due to defect in materials or workmanship under normal use and serviceas follows. All warranty periods begin on the date of original installation of the Part in the Taylor unit. If a Part failsdue to defect during the applicable warranty period, Taylor, through an authorized Taylor distributor or serviceagency, will provide a new or re- manufactured Part, at Taylor’s option, to replace the failed defective Part at nocharge for the Part. Except as otherwise stated herein, these are Taylor’s exclusive obligations under this limitedwarranty for a Part failure. This limited warranty is subject to all provisions, conditions, limitations and exclusionslisted below and on the reverse (if any) of this document.

Part’s Warranty Class Code or Part Limited Warranty Period

Class 103 Parts¹ Three (3) months

Class 212 Parts² Twelve (12) months

Class 512 Parts Twelve (12) months

Class 000 Parts No warranty

Taylor Part #072454 (Motor- 24VDC *C832/C842*) Four (4) years

LIMITED WARRANTY CONDITIONS

1. If the date of original installation of the Part cannot be otherwise verified, proof of purchase may be requiredat time of service.

2. This limited warranty is valid only if the Part is installed and all required service work in connection with thePart is performed by an authorized Taylor distributor or service agency.

3. The limited warranty applies only to Parts remaining in use by their original owner at their original installationlocation in the unit of original installation.

4. Installation, use, care, and maintenance must be normal and in accordance with all instructions contained inthe Taylor Operator’s Manual.

5. Defective Parts must be returned to the authorized Taylor distributor or service agency for credit.

6. This warranty is not intended to shorten the length of any warranty coverage provided pursuant to a separateTaylor Limited Warranty on freezer or grill equipment.

7. The use of any refrigerant other than that specified for the unit in which the Part is installed will void thislimited warranty.

1, 2 Except that Taylor Part #032129SER2 (Compressor-Air-230V SERV) and Taylor Part #075506SER1(Compressor-Air-115V 60HZ) shall have a limited warranty period of twelve (12) months when used in Taylorfreezer equipment and a limited warranty period of two (2) years when used in Taylor grill equipment.

Page 44: 0750,751,754,774,791,794op0.pdf

40 Models 750, 751, 754, 774, 791, 794Limited Warranty on Parts

LIMITED WARRANTY EXCEPTIONS

This limited warranty does not cover:

1. Labor or other costs incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling ofdefective Parts, replacement Parts, or new Parts.

2. Normal maintenance, cleaning and lubrication as outlined in the Taylor Operator’s Manual, including cleaningof condensers or carbon and grease buildup.

3. Required service, whether cleaning or general repairs, to return the cooking surface assemblies, includingthe upper platen and lower plate, to an operational condition to achieve proper cooking or allow properassembly of release sheets and clips as a result of grease build-up on the cooking surfaces, including butnot limited to the platen and plate, sides of the shroud or top of the shroud.

4. Replacement of cooking surfaces, including the upper platen and lower plate, due to pitting or corrosion (orin the case of the upper platen, due to loss of plating) as a result of damage due to the impact of spatulas orother small wares used during the cooking process or as a result of the use of cleaners, cleaning materialsor cleaning processes not approved for use by Taylor.

5. Replacement of wear items designated as Class “000” Parts in the Taylor Operator’s Manual, as well as anyrelease sheets and clips for the Product’s upper platen assembly.

6. External hoses, electrical power supplies, and machine grounding.

7. Parts not supplied or designated by Taylor, or damages resulting from their use.

8. Return trips or waiting time required because a service technician is prevented from beginning warrantyservice work promptly upon arrival.

9. Failure, damage or repairs due to faulty installation, misapplication, abuse, no or improper servicing,unauthorized alteration or improper operation or use as indicated in the Taylor Operator’s Manual, includingbut not limited to the failure to use proper assembly and cleaning techniques, tools, or approved cleaningsupplies.

10. Failure, damage or repairs due to theft, vandalism, wind, rain, flood, high water, water, lightning, earthquakeor any other natural disaster, fire, corrosive environments, insect or rodent infestation, or other casualty,accident or condition beyond the reasonable control of Taylor; operation above or below the gas, electrical orwater supply specification of the unit in which a part is installed; or Parts or the units in which they areinstalled repaired or altered in any way so as, in the judgment of Taylor, to adversely affect performance, ornormal wear or deterioration.

11. Any Part purchased over the Internet.

12. Failure to start due to voltage conditions, blown fuses, open circuit breakers, or damages due to theinadequacy or interruption of electrical service.

13. Electricity, gas or other fuel costs, or increases in electricity or fuel costs from any reason whatsoever.

14. Damages resulting from the use of any refrigerant other than that specified for the unit in which the Part isinstalled will void this limited warranty.

15. Any cost to replace, refill or dispose of refrigerant, including the cost of refrigerant.

16. ANY SPECIAL, INDIRECT OR CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGE OF ANYNATURE WHATSOEVER. Some jurisdictions do not allow the exclusion of incidental or consequentialdamages, so this limitation may not apply to you.

This limited warranty gives you specific legal rights, and you may also have other rights which vary fromjurisdiction to jurisdiction.

Page 45: 0750,751,754,774,791,794op0.pdf

41Models 750, 751, 754, 774, 791, 794 Limited Warranty on Parts

LIMITATION OF WARRANTY

THIS LIMITED WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, CONDITIONSAND/OR REMEDIES UNDER THE LAW, INCLUDING ANY IMPLIED WARRANTIES OR CONDITIONS OFMERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THE ORIGINAL OWNER’S SOLEREMEDY WITH RESPECT TO ANY PRODUCTS SHALL BE REPAIR OR REPLACEMENT OF DEFECTIVEPARTS UNDER THE TERMS OF THIS LIMITED WARRANTY. ALL RIGHTS TO CONSEQUENTIAL ORINCIDENTAL DAMAGES (INCLUDING CLAIMS FOR LOST SALES, LOST PROFITS, PRODUCT LOSS,PROPERTY DAMAGES OR SERVICE EXPENSES) ARE EXPRESSLY EXCLUDED. THE EXPRESSWARRANTIES MADE IN THIS LIMITED WARRANTY MAY NOT BE ALTERED, ENLARGED, OR CHANGEDBY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON, WHATSOEVER.

LEGAL REMEDIES

The owner must notify Taylor in writing, by certified or registered letter to the following address, of any defect orcomplaint with the Part, stating the defect or complaint and a specific request for repair, replacement, or othercorrection of the Part under warranty, mailed at least thirty (30) days before pursuing any legal rights or remedies.

Taylor Companya division of Carrier Commercial Refrigeration, Inc.

750 N. Blackhawk Blvd.Rockton, IL 61072, U.S.A.

Page 46: 0750,751,754,774,791,794op0.pdf

Section 12 Parts List

+ Available Separately

42Parts List Models 750, 751, 754, 774, 791, 794

121031

Models750,751,754,774,794

(HP62

Refrigerant:750-J6110454,751

-J6080596,754

-J6080465,774

-J6092382,and794-J4094101/up)

DESCRIPTION

PART

NUMBER

750

QTY.

751

QTY.

754

QTY.

774

QTY.

794

QTY.

WARR.

CLASS

REMARKS

PARTS

UPDATE

AD

AP

TO

RA

.-C

AS

TE

RX

1891

54

44

410

3

BE

AR

ING

-FR

ON

T05

0216

11

22

200

0

BE

AR

ING

-RE

AR

SH

ELL

0313

241

12

22

000

+G

UID

E-D

RIP

SE

AL

0289

921

12

22

000

+N

UT

-BR

AS

SB

EA

RIN

G02

8991

11

22

200

0

+W

AS

HE

R-B

EA

RIN

GLO

CK

0128

641

12

22

000

BE

AT

ER

AS

SE

MB

LYX

3176

11

12

22

103

+B

LAD

E-S

CR

AP

ER

0351

742

24

44

000

BE

LT-A

X40

0238

752

000

BE

LT-A

X35

0228

482

400

0

BE

LT-A

X34

0257

294

000

BE

LT-A

X31

0415

754

000

BLO

CK

-TE

RM

INA

L-2

P03

9422

11

22

210

3S

ING

LEP

HA

SE

BLO

CK

-TE

RM

INA

L-3

P03

9423

11

22

210

3T

HR

EE

PH

AS

E

SC

RE

W-T

ER

MIN

AL

BLO

CK

0394

202

24

44

000

BLO

WE

RA

SS

EM

BLY

X47

833-

271

11

110

3

CA

PA

CIT

OR

-RU

N03

3047

11

11

103

BO

OT

-CA

PA

CIT

OR

0313

141

11

100

0

HO

US

ING

A.-

w/W

HE

EL

X30

160

11

11

103

MO

TO

R-B

LOW

ER

0465

36-2

71

11

110

3

BO

AR

D-L

OG

ICX

6957

0SE

R2

11

22

221

2REPLA

CES

X36

641S

ER

1

BO

AR

D-P

OW

ER

X69

574-

SE

R1

12

22

212

REPLA

CES

X32

326-

SE

R

FU

SE

-SLO

BLO

0512

721

12

22

103

BR

US

H-B

LAC

K(1

”X

2”)

0130

711

11

11

000

BR

US

H-D

OU

BLE

EN

D01

3072

11

11

100

0

BR

US

H-W

HIT

E(1

”X

2”)

0130

731

11

11

000

BR

US

H-W

HIT

E(3

”X

7”)

0233

161

11

11

000

CA

BLE

-RIB

BO

N03

2445

11

22

103

CA

BLE

-RIB

BO

N04

2599

210

3

CA

P-D

ES

IGN

0142

181

13

33

000

Page 47: 0750,751,754,774,791,794op0.pdf

43

+ Available Separately

Models 750, 751, 754, 774, 791, 794 Parts List

120117

DESCRIPTION

PARTS

UPDATE

REMARKS

WARR.

CLASS

794

QTY.

774

QTY.

754

QTY.

751

QTY.

750

QTY.

PART

NUMBER

CA

PA

CIT

OR

-RU

N05

1785

110

3F

AN

MO

TO

R-

0517

44-2

713

6

CA

PA

CIT

OR

-RU

N01

9624

110

3F

AN

MO

TO

R-

0414

01-2

713

6

CA

ST

ER

-4”

SW

V5/

8S

TE

M01

8794

24

42

103

CA

ST

ER

-4”

SW

V5/

8S

TE

MW

/BR

AK

E03

4081

22

103

CO

MP

RE

SS

OR

-C

OP

ELA

ND

0519

58-2

71

512

J810

8583

/UP

-23

0-60

-113

6

CO

MP

RE

SS

OR

-C

OP

ELA

ND

0519

58-5

81

512

J810

8583

/UP

-220

-240

/380

-415

/50/

313

6

LIN

EA

.-A

CC

ES

SC

OM

PR

ES

SO

RX

4251

31

130

CO

PE

LAN

D13

6

CA

PA

CIT

OR

-RU

N01

2906

110

323

0-60

-1-

J810

8583

/UP

136

CA

PA

CIT

OR

-ST

AR

T03

3044

-11

103

230-

60-1

-J8

1085

83/U

P13

6

RE

LAY

-ST

AR

TC

OM

PR

ES

SO

R05

1957

-27

110

323

0-60

-1-

J810

8583

/UP

136

CO

MP

RE

SS

OR

-B

RIS

TO

L04

8727

-1

512

PR

IOR

TO

J810

8583

112/

136

CA

PA

CIT

OR

-RU

N02

3606

110

323

0-60

-1-

PR

IOR

TO

J810

8583

136

CA

PA

CIT

OR

-ST

AR

T03

1790

110

323

0-60

-1-

PR

IOR

TO

J810

8583

136

RE

LAY

-ST

AR

T04

8765

110

323

0-60

-1-

PR

IOR

TO

J810

8583

136

CO

MP

RE

SS

OR

-B

RIS

TO

L04

8259

-1

22

512

CA

PA

CIT

OR

-RU

N01

2906

12

210

323

0-60

-1

CA

PA

CIT

OR

-ST

AR

T03

1790

12

210

323

0-60

-1

RE

LAY

-ST

AR

T03

8145

12

210

323

0-60

-1

CO

MP

RE

SS

OR

-T

EC

UM

SE

H04

7519

-2

512

CA

PA

CIT

OR

-RU

N04

8132

210

3

CA

PA

CIT

OR

-ST

AR

T03

6048

210

3

RE

LAY

-ST

AR

T03

6047

210

3

CO

MP

RE

SS

OR

-AU

XIL

IAR

Y04

7701

-27

11

11

151

2

CA

PA

CIT

OR

-ST

AR

T04

7703

11

11

110

3

RE

LAY

-ST

AR

T04

7702

-27

11

11

110

3

CO

VE

R-T

ER

MIN

AL

0477

391

11

11

103

CO

ND

EN

SE

R-A

UX

ILIA

RY

0271

551

11

11

103

CO

ND

EN

SE

R-M

AIN

0465

581

103

CO

ND

EN

SE

R-M

AIN

0482

331

22

210

3

CO

UP

LIN

G-D

RIV

E01

2721

11

22

210

3

CO

VE

RA

.-M

IXH

OP

PE

RX

3845

8-S

ER

11

22

103

+G

AS

KE

T-M

IXH

OP

PE

R03

8375

11

000

+G

AS

KE

T-M

IXH

OP

PE

R03

8474

11

000

Page 48: 0750,751,754,774,791,794op0.pdf

+ Available Separately

44Parts List Models 750, 751, 754, 774, 791, 794

DESCRIPTION

PARTS

UPDATE

REMARKS

WARR.

CLASS

794

QTY.

774

QTY.

754

QTY.

751

QTY.

750

QTY.

PART

NUMBER

KN

OB

-MIX

HO

PP

ER

0254

291

12

210

3

CO

VE

R-M

IXH

OP

PE

R04

1682

-GR

Y2

103

DE

CA

L-D

EC

OR

AT

IVE

SO

FT

EC

H03

3230

11

000

DE

CA

L-D

EC

OR

AT

IVE

SO

FT

EC

H03

2919

11

000

DE

CA

L-D

EC

OR

AT

IVE

SO

FT

EC

H04

5812

100

0

DE

CA

L-H

EA

TE

RS

WIT

CH

0365

511

000

”ON

-OF

F”

DE

CA

L-C

LEA

N&

SA

NIT

IZE

0190

291

11

11

000

DE

CA

L-P

OW

ER

SW

ITC

H-

ON

/OF

F(O

LD)

3248

41

100

0P

RIO

RT

OJ8

0800

0013

2

DE

CA

L-P

OW

ER

SW

ITC

H-

ON

/OF

F03

2484

11

100

0

DE

CA

L-T

RO

UB

LES

HO

OT

ING

0383

741

11

11

000

DE

CA

L-W

AR

NIN

G03

6529

33

33

300

0

DE

FLE

CT

OR

-BLO

WE

RE

XH

AU

ST

0465

861

11

103

DE

FLE

CT

OR

-BLO

WE

RE

XH

AU

ST

0479

121

103

DIA

GR

AM

-WIR

ING

0526

13-

100

0J8

1085

83/U

P(C

OP

ELA

ND

)13

6

DIA

GR

AM

-WIR

ING

0503

18-

11

000

750

-P

RIO

RT

OJ8

1085

8313

6

DIA

GR

AM

-WIR

ING

0465

85-

11

000

DIA

GR

AM

-WIR

ING

0481

99-

100

0

DO

OR

A.-

FR

EE

ZE

RX

5153

1-10

11

103

+B

EA

RIN

G-F

RO

NT

0502

161

100

0

+C

AP

-DE

SIG

N01

4218

11

000

+G

AS

KE

T-D

OO

R04

8926

11

000

DO

OR

A.-

FR

EE

ZE

RX

5153

2-12

11

110

3

+B

EA

RIN

G-F

RO

NT

0502

162

22

000

+C

AP

-DE

SIG

N01

4218

33

300

0

DE

CA

L-D

OO

R02

1521

11

100

0

+G

AS

KE

T-D

OO

R04

8926

22

200

0

DR

YE

R-C

AP

ILLA

RY

0476

991

11

11

000

AU

XIL

IAR

Y

DR

YE

R-F

ILT

ER

0489

011

12

22

000

GA

SK

ET

-FR

EE

ZE

RD

OO

R04

8926

11

22

200

0

GE

AR

-RE

DU

CE

R02

1286

11

22

221

2

GU

IDE

A.-

DR

IPP

AN

X50

752

110

3

GU

IDE

A.-

DR

IPP

AN

X28

863

110

3

GU

IDE

A.-

DR

IPP

AN

X28

699

11

103

Page 49: 0750,751,754,774,791,794op0.pdf

45

+ Available Separately

Models 750, 751, 754, 774, 791, 794 Parts List

DESCRIPTION

PARTS

UPDATE

REMARKS

WARR.

CLASS

794

QTY.

774

QTY.

754

QTY.

751

QTY.

750

QTY.

PART

NUMBER

GU

IDE

A.-

DR

IPP

AN

X45

691

110

3

HA

ND

LEA

.-A

DJU

ST

AB

LED

RA

WX

2699

61

110

3

HA

ND

LE-D

RA

W02

8804

11

103

SC

RE

W-A

DJU

ST

AB

LE02

6592

11

000

PLA

ST

IC

O-R

ING

0158

721

100

0

HA

ND

LEA

.-A

DJU

ST

AB

LED

RA

WX

3368

73

33

103

J709

0000

/UP

RE

PLA

CE

SX

2699

612

1

HA

ND

LE-D

RA

W02

8804

33

310

3

SC

RE

W-A

DJU

ST

AB

LE03

3662

33

310

3S

TA

INLE

SS

121

O-R

ING

0158

723

33

000

HO

OD

AS

SE

MB

LYX

3556

51

110

3

HO

OD

0354

341

110

3

JAR

-PLA

ST

ICS

YR

UP

0365

732

103

JAR

-ST

AIN

LES

SS

YR

UP

0365

742

103

KIT

A.-

TU

NE

-UP

X49

463-

111

100

0

BE

AR

ING

-FR

ON

T05

0216

11

000

CA

P-D

ES

IGN

0142

181

100

0

GA

SK

ET

-DO

OR

0489

261

100

0

O-R

ING

0185

724

400

0A

IRT

UB

E

O-R

ING

0144

022

200

0D

RA

WV

ALV

E

O-R

ING

0162

721

100

0P

IVO

TP

IN

O-R

ING

0161

373

300

0P

RIM

EP

LUG

&A

IRO

RIF

ICE

SE

AL

0325

601

100

0D

RIV

ES

HA

FT

TO

OL-

O-R

ING

RE

MO

VA

L04

8260

-WH

T1

100

0

KIT

A.-

TU

NE

-UP

X49

463-

41

11

000

BE

AR

ING

-FR

ON

T05

0216

22

200

0

CA

P-D

ES

IGN

0142

183

33

000

GA

SK

ET

-DO

OR

0489

262

22

000

O-R

ING

0185

728

88

000

AIR

TU

BE

O-R

ING

0144

025

55

000

DR

AW

VA

LVE

O-R

ING

0162

721

11

000

PIV

OT

PIN

O-R

ING

0161

376

66

000

PR

IME

PLU

G&

AIR

OR

IFIC

E

SE

AL

0325

602

22

000

DR

IVE

SH

AF

T

SE

AL-

DR

AW

VA

LVE

0346

981

11

000

H-R

ING

Page 50: 0750,751,754,774,791,794op0.pdf

+ Available Separately

46Parts List Models 750, 751, 754, 774, 791, 794

DESCRIPTION

PARTS

UPDATE

REMARKS

WARR.

CLASS

794

QTY.

774

QTY.

754

QTY.

751

QTY.

750

QTY.

PART

NUMBER

TO

OL-

O-R

ING

RE

MO

VA

L04

8260

-WH

T1

11

000

LAB

EL-

SW

ITC

H-P

OW

ER

-OF

F/O

NS

YM

BO

L05

2632

11

000

J808

0000

/UP

-ON

PO

SIT

ION

ON

R/S

132

LAB

EL-

WA

RN

-CO

VE

R05

1433

45

67

500

0

LEG

(4”

w/O

-RIN

G)

0134

584

103

LID

-W/L

AD

LE03

6575

210

3

LOU

VE

R-S

IDE

(LE

FT

)01

3631

110

3LE

FT

LOU

VE

R-S

IDE

0174

712

22

210

3

LUB

RIC

AN

T-T

AY

LOR

4O

Z.

0475

181

11

11

000

MA

N-O

PE

R02

8754

-M1

11

11

000

MO

TO

R-B

EA

TE

R02

1522

-1

12

22

212

CA

PA

CIT

OR

-RU

N(2

30-6

0-1)

0270

871

12

22

103

MA

GN

ET

EK

/CE

NT

UR

Y23

0-30

-1

CA

PA

CIT

OR

-RU

N(2

30-6

0-1)

0360

841

12

22

103

LEE

SO

N23

0-30

-1

CA

PA

CIT

OR

-ST

AR

T(2

30-6

0-1)

0283

151

12

22

103

MA

GN

ET

EK

/CE

NT

UR

Y23

0-30

-1

CA

PA

CIT

OR

-ST

AR

T(2

30-6

0-1)

0458

621

12

22

103

LEE

SO

N23

0-30

-1

MO

TO

R-F

AN

(CO

ND

EN

SE

R)

0517

44-2

71

103

J810

8583

/UP

(CO

PE

LAN

D)

136

MO

TO

R-F

AN

(CO

ND

EN

SE

R)

0414

01-2

71

103

PR

IOR

TO

J810

8583

136

+B

LAD

E-F

AN

(12”

PU

SH

)04

7279

110

3

MO

TO

R-F

AN

(w/B

LAD

E)

0273

09-

11

11

110

3S

HR

+B

LAD

E-F

AN

0334

991

11

11

103

SH

R

NU

T-J

AM

-5/1

6-24

0296

39-B

LK3

33

000

J709

0000

/UP

121

NU

T-S

TU

D(H

AN

DS

CR

EW

)02

1508

44

103

HA

ND

SC

RE

W

NU

T-S

TU

D(L

ON

G)

0343

822

22

103

LON

G

NU

T-S

TU

D(S

HO

RT

)03

4383

22

210

3S

HO

RT

OR

IFIC

E-A

IR02

2465

-100

11

22

210

3

O-R

ING

0161

371

12

22

000

PA

IL02

3348

100

06

QT

./5.

7LI

TE

R

PA

IL01

3163

11

11

000

10Q

T./

9.5

LIT

ER

PA

N-D

RIP

0507

661

103

PA

N-D

RIP

-11

-5/8

”LO

NG

0275

031

103

PA

N-D

RIP

17-1

/4”

LON

G02

7504

11

103

PA

N-D

RIP

0350

341

103

PA

NA

.-H

ING

ED

DR

IPX

4184

41

103

PA

NE

L-R

EA

R02

0891

110

3

Page 51: 0750,751,754,774,791,794op0.pdf

47

+ Available Separately

Models 750, 751, 754, 774, 791, 794 Parts List

DESCRIPTION

PARTS

UPDATE

REMARKS

WARR.

CLASS

794

QTY.

774

QTY.

754

QTY.

751

QTY.

750

QTY.

PART

NUMBER

PA

NE

L-R

EA

R01

3637

110

3

PA

NE

L-R

EA

R01

7563

110

3

PA

NE

L-R

EA

R04

1855

110

3

PA

NE

L-R

EA

R-L

OW

ER

0425

771

103

PA

NE

LA

.-R

EA

R-U

PP

ER

X42

574

110

3

PA

NE

L-S

ER

VIC

E04

7170

110

3

PA

NE

L-S

ER

VIC

E04

6584

110

3

PA

NE

L-S

ER

VIC

E04

7077

110

3

PA

NE

L-S

ER

VIC

E04

1856

110

3

PA

NE

L-U

PP

ER

RIG

HT

SID

E04

2317

110

3

PA

NE

L-R

IGH

TS

IDE

0507

421

103

PA

NE

L-U

PP

ER

RIG

HT

SID

E02

8823

11

110

3

PA

NE

L-LO

WE

RR

IGH

TS

IDE

X24

424

110

3

PA

NE

L-LE

FT

SID

E05

0741

110

3

PA

NE

LA

.-LO

WE

RS

IDE

-LO

UV

ER

ED

-LE

FT

X39

075

110

3

PA

NE

L-U

PP

ER

SID

E02

4426

12

103

PA

NE

L-U

PP

ER

SID

E-L

EF

T02

8822

11

103

PA

NE

LA

.-LO

WE

RS

IDE

-LE

FT

X46

447

11

110

3

PA

NE

LA

.-LO

WE

RS

IDE

-RIG

HT

X46

448

11

110

3

PA

NE

LA

.-F

RO

NT

X50

754

110

3

PA

NE

LA

.-F

RO

NT

X33

237

110

3

PA

NE

LA

.-F

RO

NT

X32

956

110

3

PA

NE

LA

.-F

RO

NT

X42

539

110

3

HE

AT

ER

-ST

RIP

0239

53-4

110

3

LAB

EL-

TE

MP

ER

AT

UR

EA

DJU

ST

ME

NT

0309

941

000

PLU

G-D

RA

IN02

3953

-51

103

O-R

ING

0163

691

000

TH

ER

MO

ST

AT

-AD

JUS

TA

BLE

0499

931

103

TH

ER

MO

ST

AT

-HIL

IMIT

0499

921

103

PA

NE

LA

.-F

RO

NT

X41

820

110

3

PIN

A.-

PIV

OT

X22

820

11

103

+O

-RIN

G01

6272

11

000

PIN

A.-

PIV

OT

X20

683

11

110

3

Page 52: 0750,751,754,774,791,794op0.pdf

+ Available Separately

48Parts List Models 750, 751, 754, 774, 791, 794

DESCRIPTION

PARTS

UPDATE

REMARKS

WARR.

CLASS

794

QTY.

774

QTY.

754

QTY.

751

QTY.

750

QTY.

PART

NUMBER

+O

-RIN

G01

6272

11

100

0

PLA

TE

-DE

CO

RA

TIV

E03

3239

11

103

PLA

TE

-DE

CO

RA

TIV

E03

2961

11

103

PLA

TE

-DE

CO

RA

TIV

E04

1854

110

3

PLU

G-D

RIP

TR

AY

HO

LE02

9595

11

000

PLU

G-P

RIM

E02

8805

11

22

210

3

+O

-RIN

G01

6137

22

44

400

0

PR

OB

EA

.-M

IXX

3092

21

12

22

103

+D

ISC

0309

651

12

22

103

+S

PA

CE

R03

0966

11

22

210

3

PR

OB

EA

.-T

HE

RM

IST

OR

-H

OP

PE

RX

5071

71

11

11

103

794

-J8

1100

00/U

P13

6

PR

OB

EA

.-T

HE

RM

IST

OR

-H

OP

PE

RX

3446

61

103

PR

IOR

TO

J811

0000

136

PR

OB

EA

.-T

HE

RM

IST

OR

-B

AR

RE

LX

3160

21

12

22

103

PU

LLE

Y(B

EA

TE

RM

OT

OR

)01

6403

11

22

210

3B

EA

TE

RM

OT

OR

PU

LLE

Y(G

EA

R)

0278

221

12

22

103

GE

AR

PU

MP

-TO

PP

ING

0366

232

103

BA

LL03

2752

400

0

BO

DY

-VA

LVE

-SY

RU

PP

UM

P04

8166

210

3

O-R

ING

-1-5

/16

OD

0481

492

000

O-R

ING

-1”

OD

0481

482

000

CO

LLA

R-G

AG

ING

-1/2

0203

5514

210

3

CY

LIN

DE

R-S

YR

UP

PU

MP

0510

652

103

INS

ER

T-P

LUN

GE

R03

2758

210

3

KN

OB

-PLU

NG

ER

(w/O

-RIN

G)

0327

62-

210

303

2762

-BR

N-

0327

62-T

AN

+O

-RIN

G01

6369

200

0

LID

-PU

MP

0368

222

103

NU

T-P

LUN

GE

R03

6577

210

3

NU

T-S

PO

UT

0368

212

103

PLU

NG

ER

0365

782

103

SE

AL

AS

SE

MB

LY(w

/O-R

ING

)X

3305

72

103

+O

-RIN

G01

9330

200

0

SP

RIN

G-P

LUN

GE

R03

2761

200

0

TU

BE

-DIS

CH

AR

GE

0509

122

103

Page 53: 0750,751,754,774,791,794op0.pdf

49

+ Available Separately

Models 750, 751, 754, 774, 791, 794 Parts List

DESCRIPTION

PARTS

UPDATE

REMARKS

WARR.

CLASS

794

QTY.

774

QTY.

754

QTY.

751

QTY.

750

QTY.

PART

NUMBER

TU

BE

-PLU

NG

ER

0327

572

103

WA

SH

ER

-NY

LON

0327

602

000

RE

LAY

-CO

MP

RE

SS

OR

0127

25-

11

22

210

3

RE

LAY

-SP

DT

-30A

-240

V(A

/C)

0326

07-

11

11

103

BLO

WE

R*7

50-F

OR

FA

NM

OT

OR

0414

01-2

713

6

SA

NIT

IZE

R-K

AY

-504

1082

11

11

100

0

SH

AF

T-B

EA

TE

RD

RIV

E03

2564

11

22

210

3

+S

EA

L-D

RIV

ES

HA

FT

0325

601

12

22

000

SH

ELL

A.-

INS

ULA

TE

DX

5074

51

512

SH

ELL

A.-

INS

ULA

TE

DX

4978

51

512

SH

ELL

A.-

INS

ULA

TE

DX

5032

71

151

2

SH

ELL

A.-

INS

ULA

TE

DX

5171

11

512

J811

0000

/UP

136

SH

ELL

A.-

INS

ULA

TE

DX

4178

61

512

PR

IOR

TO

J811

0000

136

+S

TU

D-N

OS

EC

ON

E02

2822

44

44

410

3

SH

IELD

-SP

LAS

H02

2763

11

103

SH

IELD

-SP

LAS

H02

2766

11

103

SH

IELD

-SP

LAS

H02

2765

110

3

ST

AR

TE

R-B

EA

TE

RLI

NE

0419

50-

11

22

210

3

OV

ER

LOA

D-T

HE

RM

AL

0471

50-

11

22

210

3

SW

ITC

H-P

RE

SS

UR

E40

5P

SI(

A/C

)-

NE

W05

2663

110

3J8

1085

83/U

P(C

OP

ELA

ND

)13

6

SW

ITC

H-P

RE

SS

UR

E44

0P

SI(

A/C

)04

8230

11

22

210

375

0-

PR

IOR

TO

J810

8583

136

SW

ITC

H-T

OG

GLE

(PO

WE

RS

WIT

CH

)02

4295

11

103

SW

ITC

H-T

OG

GLE

(PO

WE

RS

WIT

CH

)03

7394

11

110

3

SW

ITC

H-T

OG

GLE

(HE

AT

ER

SW

ITC

H)

0126

261

103

SW

ITC

HA

.-D

RA

WX

3332

2-S

ER

11

103

AR

MA

.-S

WIT

CH

X33

326

11

103

BR

AC

KE

TA

.-S

WIT

CH

X43

722

11

103

E-R

ING

0491

781

100

0

PIN

-PIV

OT

0154

781

110

3

SP

RIN

G-L

EF

TR

ET

UR

N04

1660

11

103

SP

RIN

G-R

IGH

TR

ET

UR

N04

1661

11

103

SW

ITC

H-M

ICR

O02

8889

11

103

SW

ITC

HA

.-D

RA

WX

3854

71

11

103

Page 54: 0750,751,754,774,791,794op0.pdf

+ Available Separately

50Parts List Models 750, 751, 754, 774, 791, 794

DESCRIPTION

PARTS

UPDATE

REMARKS

WARR.

CLASS

794

QTY.

774

QTY.

754

QTY.

751

QTY.

750

QTY.

PART

NUMBER

AR

M-S

WIT

CH

-LE

FT

0386

491

11

103

AR

M-S

WIT

CH

-RIG

HT

0386

501

11

103

BR

AC

KE

TA

.-S

WIT

CH

X38

252

11

110

3

E-R

ING

0321

904

44

000

PIN

-PIV

OT

0384

841

11

103

RO

D-S

PR

ING

RE

TA

INE

R03

8254

11

110

3

SP

RIN

G-E

XT

EN

SIO

N03

8922

22

210

3

SP

RIN

G-L

EF

TR

ET

UR

N03

8923

11

110

3

SP

RIN

G-R

IGH

TR

ET

UR

N03

8924

11

110

3

SW

ITC

HA

.-D

RA

WX

3926

91

11

103

BR

AC

KE

T-S

WIT

CH

0392

641

11

103

SW

ITC

H-M

IRC

O03

9252

22

210

3

TR

AY

-FR

ON

TD

RIP

0136

901

110

3

TR

AY

-FR

ON

TD

RIP

0145

331

110

3

TR

AY

-FR

ON

TD

RIP

0201

571

103

TR

IM-F

RO

NT

0208

891

103

TR

IM-L

EF

TR

EA

RC

OR

NE

R02

0678

110

3

TR

IM-L

EF

TR

EA

RC

OR

NE

R02

0882

110

3

TR

IM-L

EF

TR

EA

RC

OR

NE

R01

3761

11

103

TR

IM-L

EF

TR

EA

RC

OR

NE

R04

1852

110

3

TR

IM-R

IGH

TR

EA

RC

OR

NE

R02

0677

110

3

TR

IM-R

IGH

TR

EA

RC

OR

NE

R02

0883

110

3

TR

IM-R

IGH

TR

EA

RC

OR

NE

R01

3663

11

103

TR

IM-R

IGH

TR

EA

RC

OR

NE

R04

1853

110

3

TU

BE

A.-

AIR

X29

429-

21

12

22

103

+O

-RIN

G01

8572

44

88

800

0

VA

LVE

-AC

CE

SS

0470

162

12

22

103

VA

LVE

-AC

CE

SS

0444

551

12

103

750

W/B

RIS

TO

LC

OM

PR

ES

SO

R13

6

VA

LVE

-AC

CE

SS

0432

321

22

103

VA

LVE

-AC

CE

SS

0444

041

11

11

103

VA

LVE

-AC

CE

SS

0294

061

11

110

3

VA

LVE

-AU

TO

MA

TIC

EX

PA

NS

ION

0463

651

12

22

103

+B

OO

T-E

XP

AN

SIO

NV

ALV

E05

0900

11

22

200

0

Page 55: 0750,751,754,774,791,794op0.pdf

51

+ Available Separately

Models 750, 751, 754, 774, 791, 794 Parts List

DESCRIPTION

PARTS

UPDATE

REMARKS

WARR.

CLASS

794

QTY.

774

QTY.

754

QTY.

751

QTY.

750

QTY.

PART

NUMBER

VA

LVE

-E.P

.R.

0226

651

11

11

103

VA

LVE

A.-

DR

AW

X18

303

11

33

310

3J7

0600

00(R

EP

LAC

ES

X45

380)

118

+O

-RIN

G01

4402

22

66

600

0

VID

EO

-TR

AIN

ING

FIL

M03

8047

-1

11

11

000

OP

TIO

NA

LF

EA

TU

RE

SA

IR/M

IXP

UM

P

BE

AR

ING

-FR

ON

T02

3262

100

0us

ew

ithou

tsho

es

BE

AR

ING

-FR

ON

T05

0348

12

000

use

w/s

hoes

0503

46/0

5034

7

SH

OE

-FR

ON

TH

ELI

X-R

EA

R05

0346

12

000

use

with

0503

48be

arin

g

SH

OE

-FR

ON

TH

ELI

X-F

RO

NT

0503

471

200

0us

ew

ith05

0348

bear

ing

BE

AT

ER

AS

SE

MB

LYX

4623

11

210

3

+B

LAD

E-S

CR

AP

ER

0462

352

400

0

+C

LIP

-SC

RA

PE

RB

LAD

E04

6236

24

103

PIN

-SC

RA

PE

RB

LAD

E01

4170

24

000

BO

AR

D-L

OG

ICX

4200

2SE

R1

12

212

CA

PA

CIT

OR

-ST

AR

T(P

UM

P)

0372

51-

12

103

DE

CA

L-C

LEA

NA

ND

SA

NIT

IZE

0421

701

100

0

DE

CA

L-D

EC

OR

AT

IVE

0332

311

000

DE

CA

L-D

EC

OR

AT

IVE

0332

321

000

GA

SK

ET

-HO

PP

ER

0383

751

200

0

GU

IDE

A.-

DR

IPP

AN

-PU

MP

X48

433

110

3ho

pper

pum

p

HO

OD

AS

SE

MB

LYX

4199

61

103

HO

OD

0136

671

103

KIT

A.-

TU

NE

-UP

X49

463-

91

000

BA

ND

-CH

EC

K(L

IQU

IDV

ALV

EB

OD

Y)

0200

502

000

BA

ND

-CH

EC

K(L

IQU

IDV

ALV

EB

OD

Y)

0332

151

000

BE

AR

ING

-FR

ON

T(F

RE

EZ

ER

DO

OR

)02

3262

100

0us

ew

ithou

tsho

es

BE

AR

ING

-FR

ON

T(F

RE

EZ

ER

DO

OR

)05

0348

100

0us

ew

/sho

es05

0346

/050

347

SH

OE

-FR

ON

TH

ELI

X-R

EA

R05

0346

100

0us

ew

ith05

0348

bear

ing

SH

OE

-FR

ON

TH

ELI

X-F

RO

NT

0503

471

000

use

with

0503

48be

arin

g

CA

P-D

ES

IGN

(FR

EE

ZE

RD

OO

R)

0142

181

000

GA

SK

ET

-DO

OR

0489

261

000

Page 56: 0750,751,754,774,791,794op0.pdf

+ Available Separately

52Parts List Models 750, 751, 754, 774, 791, 794

DESCRIPTION

PARTS

UPDATE

REMARKS

WARR.

CLASS

794

QTY.

774

QTY.

754

QTY.

751

QTY.

750

QTY.

PART

NUMBER

O-R

ING

(PR

IME

PLU

G)

0161

373

000

O-R

ING

(DR

AW

VA

LVE

)01

4402

200

0

O-R

ING

(PU

MP

DR

IVE

SH

AF

T)

0089

041

000

O-R

ING

(LIQ

UID

VA

LVE

BO

DY

)01

8664

100

0

O-R

ING

(LV

B&

PIS

TO

N)

0200

513

000

O-R

ING

(MIX

INLE

TT

UB

E)

0158

351

000

O-R

ING

(MIX

FE

ED

TU

BE

)01

6132

200

0

O-R

ING

(PIV

OT

PIN

)01

6272

100

0

PO

PP

ET

-RU

BB

ER

0224

731

000

SE

AL

(AIR

INLE

TF

ITT

ING

)04

5327

100

0

SE

AL

(BE

AT

ER

DR

IVE

SH

AF

T)

0325

601

000

O-R

ING

(PU

MP

DR

IVE

SH

AF

T)

0486

322

000

SP

RIN

G02

2456

100

0

KIT

A.-

TU

NE

-UP

X49

463-

191

000

BA

ND

-CH

EC

K(L

IQU

IDV

ALV

EB

OD

Y)

0200

504

000

BA

ND

-CH

EC

K(L

IQU

IDV

ALV

EB

OD

Y)

0332

152

000

BE

AR

ING

-FR

ON

T(F

RE

EZ

ER

DO

OR

)05

0348

200

002

3262

used

with

outs

hoes

CA

P-D

ES

IGN

(FR

EE

ZE

RD

OO

R)

0142

183

000

GA

SK

ET

-DO

OR

0489

262

000

O-R

ING

(PR

IME

PLU

G)

0161

374

000

O-R

ING

(DR

AW

VA

LVE

)01

4402

700

0

O-R

ING

(DR

IVE

CR

AN

K)

0089

042

000

O-R

ING

(LIQ

UID

VA

LVE

BO

DY

)01

8664

200

0

O-R

ING

(LV

B&

PIS

TO

N)

0200

516

000

O-R

ING

(MIX

INLE

TT

UB

E)

0158

352

000

O-R

ING

(MIX

FE

ED

TU

BE

)01

6132

400

0

O-R

ING

(PIV

OT

PIN

)01

6272

100

0

O-R

ING

(PU

MP

DR

IVE

SH

AF

T)

0486

324

000

PO

PP

ET

-RU

BB

ER

0224

732

000

SE

AL-

DR

AW

VA

LVE

0346

981

000

SE

AL

(AIR

INLE

TF

ITT

ING

)04

5327

200

0

SE

AL

(BE

AT

ER

DR

IVE

SH

AF

T)

0325

602

000

SH

OE

-FR

ON

TH

ELI

X-R

EA

R05

0346

200

0us

ew

ith05

0348

bear

ing

Page 57: 0750,751,754,774,791,794op0.pdf

53

+ Available Separately

Models 750, 751, 754, 774, 791, 794 Parts List

DESCRIPTION

PARTS

UPDATE

REMARKS

WARR.

CLASS

794

QTY.

774

QTY.

754

QTY.

751

QTY.

750

QTY.

PART

NUMBER

SH

OE

-FR

ON

TH

ELI

X-F

RO

NT

0503

472

000

use

with

0503

48be

arin

g

SP

RIN

G02

2456

200

0

TO

OL-

O-R

ING

RE

MO

VA

L04

8260

-WH

T1

000

LOU

VE

R-S

IDE

-RIG

HT

0174

711

103

LOU

VE

R-S

IDE

-LE

FT

0282

881

103

MO

TO

R-R

ED

UC

ER

0369

55-3

41

210

3

OV

ER

LOA

D(M

OT

OR

RE

DU

CE

R)

0444

641

210

3

PA

N-D

RIP

0484

351

103

HO

PP

ER

PU

MP

PA

NA

.-D

RIP

X38

198

110

3

PA

NE

L-R

EA

R04

8203

110

3

PU

MP

A.-

CO

AX

IAL

AIR

/MIX

X45

316-

B1

210

3

BA

ND

-CH

EC

K(L

IQU

IDV

ALV

EB

OD

Y)

0200

502

400

0

BA

ND

-CH

EC

K(L

IQU

IDV

ALV

EB

OD

Y)

0332

151

200

0

BO

DY

A.-

LIQ

UID

VA

LVE

X46

860-

B1

210

3

+C

LIP

-LO

CK

ING

0447

311

210

3

+C

LIP

-PU

MP

0446

411

210

3

CY

LIN

DE

RA

.-P

UM

PX

4475

51

210

3

O-R

ING

(LIQ

UID

VA

LVE

BO

DY

)01

8664

12

000

O-R

ING

(LV

B&

PIS

TO

N)

0200

513

600

0

PIN

A.-

PU

MP

X36

950

12

103

PIS

TO

N04

5319

-B1

210

3

PO

PP

ET

-RU

BB

ER

0224

731

200

0

SP

RIN

G02

2456

12

000

TU

BE

A.-

MIX

INLE

TX

4531

81

210

3

O-R

ING

0158

351

200

0

SE

AL

0453

271

200

0

RE

LAY

(MO

TO

RR

ED

UC

ER

)03

9725

-1

210

3

SH

AF

TA

.-D

RIV

EX

3908

41

210

3

O-R

ING

(DR

IVE

CR

AN

K)

0089

041

200

0

O-R

ING

(DR

IVE

CR

AN

K)

0486

322

400

0

SH

ELL

A.-

INS

ULA

TE

DX

5033

21

512

SH

ELL

A.-

INS

ULA

TE

DX

5037

61

512

SLE

EV

EA

.-M

IXP

UM

PX

4501

21

210

3

Page 58: 0750,751,754,774,791,794op0.pdf

+ Available Separately

54Parts List Models 750, 751, 754, 774, 791, 794

DESCRIPTION

PARTS

UPDATE

REMARKS

WARR.

CLASS

794

QTY.

774

QTY.

754

QTY.

751

QTY.

750

QTY.

PART

NUMBER

+N

UT

-PU

MP

SLE

EV

E03

6933

12

103

TU

BE

A.-

MIX

FE

ED

X44

666

110

3

+O

-RIN

G01

6132

200

0

TU

BE

A.-

FE

ED

(LE

FT

)X

4466

21

103

TU

BE

A.-

FE

ED

(RIG

HT

)X

4466

41

103

O-R

ING

-FE

ED

TU

BE

0161

324

000

VID

EO

-TR

AIN

ING

0472

47-

11

000

WA

TE

RC

OO

LE

DB

LOW

ER

0127

96-

11

11

103

+G

UA

RD

-BLO

WE

R02

2505

11

11

103

CO

ND

EN

SE

R04

9309

110

3

CO

ND

EN

SE

R04

8287

12

22

103

MO

TO

R-F

AN

0151

84-

110

3

+B

LAD

E-F

AN

(10”

PU

SH

)01

3043

110

3

PA

NE

LA

.-LO

WE

RS

IDE

(R&

L)X

2442

42

22

210

3

SW

ITC

H-P

RE

SS

UR

E04

8231

11

22

210

3

VA

LVE

-WA

TE

R04

6686

11

22

103

Page 59: 0750,751,754,774,791,794op0.pdf

55

+ Available Separately

Models 750, 751, 754, 774, 791, 794 Parts List

DESCRIPTION

PARTS

UPDATE

REMARKS

WARR.

CLASS

794

QTY.

774

QTY.

754

QTY.

751

QTY.

750

QTY.

PART

NUMBER

50C

YC

LE

BE

LT-A

X35

0228

484

000

BE

LT-A

X32

0327

694

000

BLO

CK

-TE

RM

INA

L(2

30-5

0-1)

0394

211

12

103

BLO

CK

-TE

RM

INA

L(2

20/4

40-5

0-3)

0394

241

12

22

103

CA

PA

CIT

OR

-RU

N(B

EA

TE

RM

OT

OR

)02

3606

11

22

210

3C

EN

TU

RY

/MA

GN

ET

EK

CA

PA

CIT

OR

-RU

N(B

EA

TE

RM

OT

OR

)03

5765

-27

11

22

210

3LE

ES

ON

CA

PA

CIT

OR

-ST

AR

T(B

EA

TE

RM

OT

OR

)02

8315

11

22

210

3C

EN

TU

RY

/MA

GN

ET

EK

CA

PA

CIT

OR

-ST

AR

T(B

EA

TE

RM

OT

OR

)02

6659

11

22

210

3LE

ES

ON

CO

MP

RE

SS

OR

(MA

IN-

HP

62)

0487

27-

151

2B

RIS

TO

L

CA

PA

CIT

OR

-RU

N(2

30-5

0-1)

0270

871

103

CA

PA

CIT

OR

-ST

AR

T(2

30-5

0-1)

0317

901

103

RE

LAY

-ST

AR

T(2

30-5

0-1)

0487

661

103

CO

MP

RE

SS

OR

(MA

IN-

HP

62)

0482

59-

12

251

2B

RIS

TO

L

CA

PA

CIT

OR

-RU

N(2

30-5

0-1)

0237

391

210

3

CA

PA

CIT

OR

-ST

AR

T(2

30-5

0-1)

0317

901

210

3

RE

LAY

-ST

AR

T(2

30-5

0-1)

0381

461

210

3

CO

MP

RE

SS

OR

-MA

IN(H

P62

)04

7519

-2

512

TE

CU

MS

EH

CA

PA

CIT

OR

-RU

N(2

30-5

0-1)

0294

392

103

CA

PA

CIT

OR

-ST

AR

T(2

30-5

0-1)

0360

482

103

RE

LAY

-ST

AR

T(2

30-5

0-1)

0360

472

103

MO

TO

R-F

AN

0471

78-3

41

103

BLA

DE

-FA

N(1

2”P

US

H)

0472

791

103

PU

LLE

Y(B

EA

TE

RM

OT

OR

)01

1545

11

22

210

3

Page 60: 0750,751,754,774,791,794op0.pdf

+ Available Separately

56Parts List Models 750, 751, 754, 774, 791, 794

121031

Model791

DESCRIPTION

PART

NUMBER

791

QTY.

WARR.

CLASS

REMARKS

079127RW00

-208-230V60HZ1P

H,079133R

W00

-208-230V60HZ3P

H-3WIRE,W

/C-B

RISTO

L(R404A

),ROHSCOMPLIANT-STD

ARM-D

RAW

SWITCH-LEFT

069166

1103

ARM-D

RAW

SWITCH-R

IGHT

069167

1103

BEARING-FRONT

050216

2000

BEARING-R

EARSHELL

031324

2000

+GUIDE-D

RIP

SEAL

028992

2000

+NUT-BRASSBEARING

028991

2000

+WASHER-BEARINGLO

CK

012864

2000

BEATERASSEMBLY

X31761

2103

+BLA

DE-SCRAPER

035174

12000

BELT-AX31

041575

4000

BLO

CK-TERMINAL2P

.25SPADE

069015

1103

BLO

WER-100

CFM

012796-27

1103

+GUARD-BLO

WER

022505

1103

BOARD-LOGIC-G

EN2.10-W

/SELDI

X69570S

ER2

2212

REPLA

CESX36641S

ER2

BOARD-POWER

X69574-SER

2212

REPLA

CESX32326-SER

BRUSH-BLA

CK(1”X2”)

013071

1000

BRUSH-D

OUBLE

END

013072

1000

BRUSH-W

HITE(1”X2”)

013073

1000

BRUSH-W

HITE(3”X7”)

023316

1000

CABLE

-RIBBON

069474-60

2103

REPLA

CES032445

CAP-D

ESIGN

014218

3000

CASTER-4”SWV5/8”STEM

018794

2103

CASTER-4”SWV5/8”STEMW/BRAKE

034081

2103

CHANNEL-REARBEARINGDRIP

*794

041819

1103

COMPRESSORL64A

113B

BCA-40

048259-27H

1512

208-230V

60HZ1P

H

CAPACITOR-STA

RT189-227U

F/33

033044-1

1103

CAPACITOR-R

UN25UF/440V

037431

1103

RELAY-STA

RT-C

OMPRESSOR

062363

1103

COMPRESSORL63A

113D

BLA

-40W

CCH

048259-33H

1512

208-230V

60HZ3P

H-3WIRE

COMPRESSOR-AUXILIARY

047701-27

1512

Page 61: 0750,751,754,774,791,794op0.pdf

57

+ Available Separately

Models 750, 751, 754, 774, 791, 794 Parts List

DESCRIPTION

REMARKS

WARR.

CLASS

791

QTY.

PART

NUMBER

+CAPACITOR-STA

RT60UF-220/275V

047703

1103

+RELAY-STA

RT-C

OMPRESSOR-TL3G

047702-27

1103

+CAPACITOR-STA

RT60UF-220/275V

047739

1103

+DRYER-C

AP.TUBE.026ID

X13FT

047699

1000

+KIT-M

OUNTING-C

OMPRESSOR

047704

1000

CONDENSER-AUXILIARY

027155

1103

CONDENSER-W

C-C

OAX

047540

1103

CORD-POWER250V

30A*791*

069576-27

11

208-230V

60HZ1P

H

CORD-POWER250V

20A*791*

069576-33

11

208-230V

60HZ3P

H-3WIRE

COUPLING-D

RIVE

012721

2103

COVER-M

IXHOPPER

041682-G

RY

2103

DECAL-DEC-TAYLO

R791

069910

1000

DECAL-DOOR-3

SPOUT-TWIN

TWIS

021521

1000

DECAL-INST-C

LNHPR

019029

1000

DECAL-TROUBLE

SHOOT

038374

1000

DIAGRAM-W

IRING*791*

069543-27

1000

208-230V

60HZ1P

H

DIAGRAM-W

IRING*791*

069543-33

1000

208-230V

60HZ3P

H-3WIRE

DOORA.-3SPOUT

X51532-12

1103

+BEARING-FRONT

050216

2000

+DECAL-DOOR-3

SPOUT-TWIN

TWIS

021521

1000

+GASKET-D

OORHT4”-D

OUBLE

048926

2000

+HANDLE

A.-DRAW

ADJU

STA

BLE

X55096

3103

+LABEL-FLAVOR

036693

1000

+PLU

G-PRIME

028805

2103

+O-R

ING-3/8ODX.070W

016137

4000

+RODA.-PIVOT

X20683

1103

+O-R

ING-5/16ODX.070W

016272

1000

+VALVEA.-DRAW

X69539

3103

+O-R

ING-13/16

ODX.103W

019330

6000

DRYER-C

APILLA

RY

047699

1000

AUXILIARY

DRYER-FILTER3/8X3/8S

OLHP62

049154

1000

FUSE-.063A

-250V-5X20MM-SLO

BLO

051272

2000

GASKET-FREEZERDOOR

048926

2000

Page 62: 0750,751,754,774,791,794op0.pdf

+ Available Separately

58Parts List Models 750, 751, 754, 774, 791, 794

DESCRIPTION

REMARKS

WARR.

CLASS

791

QTY.

PART

NUMBER

GEAR-R

EDUCER

021286-SER

2212

GUIDEA.-DRIP

PAN

X45691

1103

HARNESS-W

IRE-D

ANFOSS*794*

067147-27

1103

HARNESS-W

IRE-C

NTRLSWITCH*79

069601

1103

HARNESS-W

IRE-C

ONTROL-R*791*

069633-27R

1103

208-230V

60HZ1P

H

HARNESS-W

IRE-C

ONTROL-R*791*

069633-33R

1103

208-230V

60HZ3P

H-3WIRE

HARNESS-W

IRE-C

ONTROL-L*7

069633-27L

1103

208-230V

60HZ1P

H

HARNESS-W

IRE-C

ONTROL-L*791*

069633-33L

1103

208-230V

60HZ3P

H-3WIRE

HARNESS-W

IRE-BEATERMTR*C

066440-27G

2103

208-230V

60HZ1P

H

HARNESS-W

IRE-BEATERMTR*C71

066440-33G

2103

208-230V

60HZ3P

H-3WIRE

HARNESS-W

IRE-C

OMPRESSOR*794*

068644-33

1103

208-230V

60HZ3P

H-3WIRE

HARNESS-W

IRE-SOLVLV*791*

069634

1103

INTERLO

CKA.-DOOR

X65658

*103

SEE-SWITCHA.-REEDINTERLO

CKDOOR

KITA.-COVER-H

OPPER*DUAL*GRAY

X68150

1103

COVER-H

OPPER-14QT-G

RAY

041682-G

RY

2103

KITA.-TUNEUP-3

SPOUT-N

OX49463-4

1000

BEARING-FRONT

050216

2000

CAP-D

ESIGN1.010”ID-6

POINT

014218

3000

GASKET-D

OORHT4”-D

OUBLE

048926

2000

KITA.-SILICONO-R

INGS

X69575

1000

O-R

ING-13/16

ODX.103W

019330

6000

LABEL-INSTRUCTIONO-R

INGUSA

069561

1000

O-R

ING-.643ODX.077W

018572

8000

O-R

ING-3/8ODX.070W

016137

6000

O-R

ING-5/16ODX.070W

016272

1000

O-R

ING-7/8ODX.103W

014402

6000

SEAL-DRAW

VALVE

034698

1000

SEAL-DRIVESHAFT

032560

2000

TOOL-O-R

INGREMOVAL-FREEZER

048260-W

HT

1000

LABEL-3P

HMTRPROT/1PHC-ENG/S

025949

1000

208-230V

60HZ3P

H-3WIRE

LABEL-ATTNSVCENG

015068

2000

LABEL-CKMTRROTATE-C

W-ENG/SPN

020090

1000

208-230V

60HZ3P

H-3WIRE

LABEL-CAUTION-G

RD-PERM-ENG/SP

032164

1000

Page 63: 0750,751,754,774,791,794op0.pdf

59

+ Available Separately

Models 750, 751, 754, 774, 791, 794 Parts List

140718

DESCRIPTION

REMARKS

WARR.

CLASS

791

QTY.

PART

NUMBER

LABEL-FLAVOR

036693

1000

LABEL-DOOR-W

ARN-M

OVEPARTS

032749

1000

LABEL-SW-POWER-O

FF/ON-SYMBOLS

052632

1000

LABEL-WARN-C

ONDENSER-SHARP

059287

1000

LABEL-WARN-C

OVER

051433

4000

LABEL-WARN-ELE

C-TW-SMALL

032718

1000

LABEL-WIRINGSINGLE

PHASE

036880-2

1000

208-230V

60HZ1P

H

LUBRICANT-TAYLO

R4OZ.

047518

1000

MAN-O

PER

028754-M

1000

MOTO

RA.-FA

NX69411-27

2103

MOTO

R-1.5HPCAPS@10&2O’

021522-27

2212

208-230V

60HZ1P

H

MOTO

R-1.5HP

021522-33

2212

208-230V

60HZ3P

H-3WIRE

MOTO

R-FAN

062253-27

1103

NUT-STUD-LO

NG

034382

2103

NUT-STUD-SHORT

034383

2103

ORIFICE-AIR

022465-100

2103

O-R

ING

016137

4000

PAIL-10QT.

013163

1000

10QT./9.5LITER

PANA.-HINGEDDRIP

X41844

1103

PAN-D

RIP

035034

1103

PANELA.-FRONT*794*

X41820-SP3

1103

PANEL-REAR

041855

1103

PANEL-SERVICE

064000

1103

PANEL-SIDE*794*WC

069038

2103

PLATE-D

ECORATIVE

041854

1103

PLU

G-H

OLE

7/8DIA.B

LACK

010077

2000

PLU

G-PRIME

028805

2103

PLU

G-H

OLE

1-3/4DIA.

027132

1000

PLU

G-H

OLE

1DIA-BLK

PLA

STIC

027143

2000

PLU

G-H

OLE

1-3/8DIA.-BLA

CK

053361

2000

PROBEA.-MIX

X30922

2103

+DISC-PROBE*SQHOLE

*030965

2103

+SPACER-PROBE*SQHOLE

*030966

2103

Page 64: 0750,751,754,774,791,794op0.pdf

+ Available Separately

60Parts List Models 750, 751, 754, 774, 791, 794

130122

DESCRIPTION

REMARKS

WARR.

CLASS

791

QTY.

PART

NUMBER

PROBEA.-MIX

OUT-SQUAREHOLE

X41348

2103

SPACER-PROBE-SQUAREHOLE

-7/8

041346

2103

SPACER-PROBE-R

OUNDHOLE

-5/8DIA

041347

2103

PROBEA.-THERMISTO

R-BARREL

X31602

2103

PROBEA.-THERMISTO

R-HOPPER

X50717

1103

PULLEY-2AK22

X.625-.6265

016403

2103

BEATERMOTO

R

PULLEY-2AK74-5/8

027822

2103

GEAR

RELAY-3

POLE

-20A

-208/240

50/60

066795-33

1103

RELAY-D

PDT100U

ATO

7A052111-76

2103

RELAY-D

PDT100U

ATO

7A1/8H

P052111-03

1103

RELAY-STA

RT-C

OMPRESSOR-TL3G

047702-27

1103

SANITIZER-STERASHEEN-G

REEN

055492

1000

SHAFT-BEATERDRIVE

032564

2103

+SEAL-DRIVESHAFT

032560

2000

SHELL

A.-INSULATED*794*M

IXOUT

X68678-SP4

1512

+STUD-N

OSECONE

068410

4103

SPRING-EXTENSION.467X.062X1.

069392

2103

SPRING-R

ETURN-LEFT-TWIN

TWIS

038923

1103

SPRING-R

ETURN-R

IGHT-TWIN

TWIST

038924

1103

SPRING-C

OMP.970

X.115

X2.00

025707

4000

BEATERMOTO

R

STA

RTER-1

PHASE6.3TO

10066794-27K

2103

208-230V

60HZ1P

H

OVERLO

AD-THERMAL-1P

-6.3/10A

067461-1K

2103

STA

RTER-3

PHASE4TO

6.5AMP

066794-33J

2103

208-230V

60HZ3P

H-3WIRE

OVERLO

AD-THERMAL-3P

-4.0/6.5A

067461-3J

2103

SWITCHA.-DRAW

*SELF

CLO

SING

X69821

1103

ARM-D

RAW

SWITCH-LEFT

069166

1103

ARM-D

RAW

SWITCH-R

IGHT

069167

1103

BRACKETA.-SPRING-R

ETURN

X69481

1103

BRACKETA.-SWITCH*338/39/75

X69388

1103

E-R

ING1/4BLA

CKPHOS

032190

3000

PIN-PIVOT-D

RAW

SWITCH

038484

1103

ROD-SPRINGRETA

INER

038254-SP

1103

SCREW-8-32X

3/8SLO

THEXWASH

039267

2000

Page 65: 0750,751,754,774,791,794op0.pdf

61

+ Available Separately

Models 750, 751, 754, 774, 791, 794 Parts List

120824

DESCRIPTION

REMARKS

WARR.

CLASS

791

QTY.

PART

NUMBER

SCREW-ADJU

STMENT-D

RAW

PADDLE

069374

2000

SPRING-EXTENSION.467X.062X1.

069392

2103

SPRING-R

ETURN-LEFT-TWIN

TWIS

038923

1103

SPRING-R

ETURN-R

IGHT-TWIN

TWI

038924

1103

SWITCHA.-DRAW-TWIN

TWIST

X39269

1103

SWITCH-LEVER-SPDT-11A

-125-277V

039252

2103

SWITCHA.-REEDINTERLO

CKDOOR

X65658

1103

SWITCH-R

EED*DOORINTERLO

CK*6

056771

1103

SWITCH-PRESSURE350PSI-SOLD

ER

048231

1103

SWITCH-R

EED*DOORINTERLO

CK*68”

056771

1103

SWITCH-LEVER-SPDT-11A

-125-277V

039252

2103

TRAY-D

RIP

16-7/8LX5-1/8

020157

1103

TRIM-C

ORNER-R

EAR-R

*794*

068689

1103

TRIM-C

ORNER-R

EAR-L

*794*

068690-SP2

1103

TUBEA.-FEED-SS-5/32HOLE

X29429-2

1103

VALVEA.-DRAW

X69539

3103

+O-R

ING-13/16

ODX.103W

019330

6000

VALVE-ACCESS-1/4FLX1/4S

OLD

ER

044404

1103

VALVE-ACCESS-1/4MFLX

1/4S-90

047016

2103

VALVE-ACCESS-1/4FLX3/8S

OLD

ER

043232

1103

VALVE-EPR1/4S

022665

1103

VALVE-EXP-AUTO

-1/4SX1/4FPT

046365

2103

VALVE-SOLE

NOID

7/16

ORF5/8ODF

048626-27

2103

VALVE-SOLE

NOID

7/64ORFX1/4S

043449-27

2103

Page 66: 0750,751,754,774,791,794op0.pdf

+ Available Separately

62Parts List Models 750, 751, 754, 774, 791, 794

DESCRIPTION

REMARKS

WARR.

CLASS

791

QTY.

PART

NUMBER

079133RWEW,208-230V60HZ3P

H-3WIRE,W

/C-B

RISTO

L-(R404A

),ROHSCOMPLIANT,ADJU

STA

BLEFEEDTUBE

DECAL-DOOR-M

ENCHIES-794

067494

1000

DECAL-DEC-M

ENCHIES*791*M

IXOUT

069977

1000

DOORA.-3SPOUT*M

ENCHES*

X51532-24

1103

+BEARING-FRONT

050216

2000

+DECAL-DOOR-M

ENCHIES-794

067494

1000

+GASKET-D

OORHT4”-D

OUBLE

048926

2000

+HANDLE

A.-DRAW

ADJU

STA

BLE

X55096

3103

+LABEL-FLAVOR

036693

1000

+PLU

G-PRIME

028805

2103

+O-R

ING-3/8ODX.070W

016137

4000

+RODA.-PIVOT

X20683

1103

+O-R

ING-5/16ODX.070W

016272

1000

+VALVEA.-DRAW

X69539

3103

+O-R

ING-13/16

ODX.103W

019330

6000

KITA.-TUNEUP-3

SPOUT-N

ONHT

X49463-4A

1000

KITA.-SILICONO-R

INGS

X69575

1000

O-R

ING-13/16

ODX.103W

019330

6000

LABEL-INSTRUCTIONO-R

INGUSA

069561

1000

CAP-D

ESIGN1.010”ID-6

POINT

014218

3000

O-R

ING-7/8ODX.103W

014402

6000

O-R

ING-3/8ODX.070W

016137

6000

O-R

ING-5/16ODX.070W

016272

1000

O-R

ING-.291ID

X.080W

018550

6000

O-R

ING-.643ODX.077W

018572

4000

SEAL-DRIVESHAFT

032560

2000

SEAL-DRAW

VALVE

034698

1000

TOOL-O-R

INGREMOVAL-FREEZER

048260-W

HT

1000

GASKET-D

OORHT4”-D

OUBLE

048926

2000

BEARING-FRONT

050216

2000

TUBEA.-FEED-INNER-AIR/MIX

X67103

2103

Page 67: 0750,751,754,774,791,794op0.pdf

63

+ Available Separately

Models 750, 751, 754, 774, 791, 794 Parts List

130122

DESCRIPTION

REMARKS

WARR.

CLASS

791

QTY.

PART

NUMBER

079133RWFD,208-230V60HZ3P

H-3WIRE,W

/C-B

RISTO

L-(R404A

),ROHSCOMPLIANT-R

EARMIXLIGHTS,ADJFEEDTUBE-R

EARPULLHANDLE

ADJFEEDTUBE-R

EARPULLHANDLE

COVER-BOX-LIGHT-M

IXLVL-R

080515

1103

HANDLE

-STNLS

FLU

SHPULL

019043

2103

HARNESS-W

IRE-R

MLL*791*

080516

1103

HARNESS-W

IRE-C

NTRLSWITCH

069601-SP

1103

LIGHT-AMBER-R

OUND-250V-M

I080039-27

2103

LIGHT-AMBER-R

OUND-250V-M

I080040-27

2103

PANEL-SIDE*794*W

C*LEFT

069038-SP

1103

PANEL-SIDE*794*W

C*RIGHT

069038-SP1

1103

PCBA.-DUALMIX

LVL-24V

X41420-SER

2212

CHIP-SOFTWAREMIX

LEVEL

X40799-SER

1103

RELAY-D

PDT100U

ATO

7A052111-76

4103

SHELL

A.-INSULATED*794*M

OX68678-SP6

1512

TRIM-C

ORNER-R

EAR-L

*791*

068690-SP3

1103

TRIM-C

ORNER-R

EAR-R

*794*

068689-SP1

1103

TUBEA.-FEED-INNER-AIR/MI

X67103

2103

TUBEA.-FEED-O

UTER-H

TX67104

2103

079133RWEX,208-230V60HZ3P

H-3WIRE,W

/C-B

RISTO

L-(R404A

),ROHSCOMPLIANT,HOPPERAGITATO

R-R

EARMIX

LIGHT-YOGURTLAND

ADAPTO

RA.-CASTER

X18915

4103

BLA

DEA.-AGITATO

R*794*

X56591-SP

2103

BLO

CK-TERMINAL3P

20A,300V

051331

1103

BUSHING-SNAP1-5/16ID

X1-1/

017008

2103

BUSHING-SNAP5/8IDX3/4O

D-B

017462

2000

BUSHING-SNAP3/4IDX1”ODBL

053144

2103

CONTROL-MIX

LEVEL-ROHS

065840

2103

CASTER-4”SWV5/8STEMW/

034081

2103

CASTER-4”SWV5/8STEMX

018794

2103

CD-O

PSTRAIN

794YOGURTLA

068592-YGL

1000

COVER-BOX-LIGHT-M

IXLVL-R

080515

1103

DOORA.-FREEZER3SPOUTT

X49461-37S

1103

+BAFFLE

A.-LO

NG4IN

W/RADTH

X50882

2103

Page 68: 0750,751,754,774,791,794op0.pdf

+ Available Separately

64Parts List Models 750, 751, 754, 774, 791, 794

DESCRIPTION

REMARKS

WARR.

CLASS

791

QTY.

PART

NUMBER

+BEARING-FRONT

050216

2000

+GASKET-D

OORHT4”-D

OUBLE

048926

2000

+HANDLE

A.-DRAW

*794*WHITE

X81010-SP

3000

PULL

DOWNHANDLE

12/10/12

&UP

+LABEL-FLAVOR

036693

1000

+O-R

ING-13/16

ODX.103W

019330

6000

+O-R

ING-3/8ODX.070W

016137

4000

+O-R

ING-5/16ODX.070W

016272

1000

+PLU

G-PRIME

028805

2103

+RODA.-PIVOT

X20683

1103

+VALVEA.-DRAW

X69539

3103

HANDLE

-STNLS

FLU

SHPULL

019043

2103

HARNESS-W

IRE-C

AP-AGIT*791*

080517

1103

HARNESS-W

IRE-C

NTRLSWITCH

069601-SP

1103

HARNESS-W

IRE-R

MLL*791*

080516-G

1

SOCKET-R

ELAY-FORUSEW/05211

052112

4103

BLO

CK-TERMINAL2P

.25SPADE

069015

2103

HARNESS-W

IRE-C

AP-AGIT*791*

080517

1103

HARNESS-W

IRE-SWITCH-AGIT*

069407

1103

SWITCH-TOGGLE

-SPST-3/4HP/25

012626

2103

HOUSINGA.-AGITATO

R*C708

X56586-03

2103

BODY-AGITATO

RHOUSING*C708*

056588

1103

CAP-AGITATO

RHOUSING

080827

1103

MAGNETA.-AGITATO

R-INNER

066937

1103

MOTO

R-AGITATO

R-24VAC50/60H

050535-03

1103

O-R

ING-1-3/8ODX.070W

017395

1000

PLATE-H

OLD

ING-AGITATO

R*C708

056587

1103

SCREW-4-40X

1/4SOCKETHEAD

600165

4000

SCREW-8-32X

3/16

SOCKETSET

006812

2000

KITA.-TUNEUP-3

SPOUT-N

OX49463-4B

1000

LABEL-SWITCH-AGIT.OFF/ON-

067719

2000

LIGHT-AMBER-R

OUND-250V-M

I080039-27

2103

LIGHT-AMBER-R

OUND-250V-M

I080040-27

2103

M2016393&UP

LUBRICANT-TAYLO

RHIP

ERF

048232

1000

Page 69: 0750,751,754,774,791,794op0.pdf

65

+ Available Separately

Models 750, 751, 754, 774, 791, 794 Parts List

DESCRIPTION

REMARKS

WARR.

CLASS

791

QTY.

PART

NUMBER

MOTO

R-AGITATO

R-24VAC50/60HZ

050535-03

2103

+CAPACITOR-M

OTO

R-AGITATO

R057525

2103

PANELA.-FRONT*794*

X41820-SP4

1103

PANEL-SIDE*794*W

C*LEFT

069038-SP

1103

PANEL-SIDE*794*W

C*RIGHT

069038-SP1

1103

PCBA.-DUALMIX

LVL-24V

X41420-SER

2212

CHIP-SOFTWAREMIX

LEVEL

X40799-SER

2103

RELAY-D

PDT100U

ATO

7A052111-76

6103

SHELL

A.-INSULATED*794*M

O*HA

X68678S

SP5

1S/N

M2036866&UP

SWITCH-TOGGLE

-SPST-3/4HP/25

012626

2103

TRIM-C

ORNER-R

EAR-L

*791*

068690-SP3

1103

M2016393&UP

TRIM-C

ORNER-R

EAR-R

*794*

068689-SP1

1103

M2016393&UP

Page 70: 0750,751,754,774,791,794op0.pdf

Models 750&751052613- 27Rev. 8/10

Page 71: 0750,751,754,774,791,794op0.pdf

Models 750&751052613- 33Rev. 8/10

Page 72: 0750,751,754,774,791,794op0.pdf

Models 750&751052613- 40Rev. 8/10

Page 73: 0750,751,754,774,791,794op0.pdf

Models 750&751052613- 58Rev. 8/10

Page 74: 0750,751,754,774,791,794op0.pdf

Models 754&774046585- 27Rev. 8/10

Page 75: 0750,751,754,774,791,794op0.pdf

Models 754&774046585- 33Rev. 8/10

Page 76: 0750,751,754,774,791,794op0.pdf

Model 791069543- 27Rev. 10/12

Page 77: 0750,751,754,774,791,794op0.pdf

Model 794048199- 27Rev. 10/12

Page 78: 0750,751,754,774,791,794op0.pdf

Model 794048199- 33Rev. 10/12

Page 79: 0750,751,754,774,791,794op0.pdf

Model 794048199- 62Rev. 10/12