Top Banner
Figure-D (Main Control Panel Functions) A. Select Button: Scrolls menu through filter cycle pro- gramming features. B. Cycle Button: Accesses filter cycle program mode and advances display to next cycle. C. Mode Button: Switches between standard and econo- my modes. D. Display Button: Displays time of day and initiates time setting and locking functions. E. Jets 2 Button: Controls jets pump #2 (and Maxxus Jets Pump #3) F. Jets 1 Button: Controls the 1-speed jets pump #1 G. Blower Button: Controls the air blower (on, off). H. Light Button: Controls hot tub footwell and waterfall light. I. Invert Button: Inverts the main 4-digit LCD display. J. Warmer (+) and Cooler (-) Buttons: These display temper- ature setting and increase or decrease temperature setting and other programming features. *Display shown for example purposes only, actual water temperature will vary. Figure-E (LCD Screen Functions) = Lock: Indicates panel, set temperature, or filter cycle programming is locked. = Heat: Indicates heater is on. = Ozone: Indicates optional CD ozonator is on. = Adjust Filter Cycle: Indicates filter cycle program- ming feature is accessed. = Filter Cycle Number: Indicates whichprogrammed filter cycle is running. = Filter Cycle: Indicates programmed filter cycle is running. = Filter Cycle Start Time: Indicates filter cycle start time programming is accessed. = Filter Cycle Duration: Indicates filter cycle duration programming is accessed. = Set Temperature: Indicates the current set temperature is displayed. = Set Time: Indicates current time is displayed. = Filter Annunicator: Indicates filter cleaning and/or replacement. = Light: Indicates light is on. = Blower: Indicates blower in on. = Jets 1: Indicates jets pump 1 is on. = Jets 2: Indicates jets pump 2 is on. = Mode: Indicates selected filter mode. Note: No icon means Economy mode is selected. ADDENDUM - Sundance Hot Tubs The control panel buttons and display symbols on some hot tubs has recently changed. This page replaces Figures D-E in specified owners manuals and has been provided to simplify setup and operation of your new hot tub! 6530-823, Rev.A STANDARD AM PM ADDENDUM: This text replaces Figure-D in all Sundance 880 LCD Series Owners Manuals. ADDENDUM: This text replaces Figure-E in all Sundance 880 LCD Series Owners Manuals. STANDARD STANDARD AM PM A B C D E G H I J F
78
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 06880 Eng Man

Figure-D (Main Control Panel Functions)

A. Select Button: Scrolls menu through filter cycle pro-gramming features.

B. Cycle Button: Accesses filter cycle program mode and advances display to next cycle.

C. Mode Button: Switches between standard and econo-my modes.

D. Display Button: Displays time of day and initiates time setting and locking functions.

E. Jets 2 Button: Controls jets pump #2 (and Maxxus Jets Pump #3)

F. Jets 1 Button: Controls the 1-speed jets pump #1

G. Blower Button: Controls the air blower (on, off).

H. Light Button: Controls hot tub footwell and waterfall light.

I. Invert Button: Inverts the main 4-digit LCD display.

J. Warmer (+) and Cooler (-) Buttons: These display temper-ature setting and increase or decrease temperature setting and other programming features.

*Display shown for example purposes only, actual water temperature will vary.

Figure-E (LCD Screen Functions)

= Lock: Indicates panel, set temperature, or filter cycle programming is locked.

= Heat: Indicates heater is on.

= Ozone: Indicates optional CD ozonator is on.

= Adjust Filter Cycle: Indicates filter cycle program-ming feature is accessed.

= Filter Cycle Number: Indicates whichprogrammed filter cycle is running.

= Filter Cycle: Indicates programmed filter cycle is running.

= Filter Cycle Start Time: Indicates filter cycle start time programming is accessed.

= Filter Cycle Duration: Indicates filter cycle duration programming is accessed.

= Set Temperature: Indicates the current set temperature is displayed.

= Set Time: Indicates current time is displayed.

= Filter Annunicator: Indicates filter cleaning and/or replacement.

= Light: Indicates light is on.

= Blower: Indicates blower in on.

= Jets 1: Indicates jets pump 1 is on.

= Jets 2: Indicates jets pump 2 is on.

= Mode: Indicates selected filter mode. Note: No icon means Economy mode is selected.

ADDENDUM - Sundance Hot TubsThe control panel buttons and display symbols on some hot tubs has recently changed. This page replaces Figures D-E in specified owners manuals and has been provided to simplify setup and operation of your new hot tub!

6530-823, Rev.A

STANDARD

AMPM

ADDENDUM:This text replaces Figure-D in all Sundance 880 LCD

Series Owners Manuals.

ADDENDUM:This text replaces Figure-E in all Sundance 880 LCD

Series Owners Manuals.

STANDARD

STANDARD

AMPM

A

B

C

D

EGHI

J

F

Page 2: 06880 Eng Man

AltamarTM • CameoTM • CapriTM • MajestaTM • MarinTM • MaxxusTM • OptimaTM

6530-395, Rev. B

Page 3: 06880 Eng Man

pH 7.2 - 7.4Free Chlorine 3-5 ppmFree Bromine 4-6 ppmTotal Alkalinity 100-120 ppmCalcium Hardness 150-250 ppm

Attention New Hot Tub Owner!Congratulations on the purchase of your new Sundance® hot tub! The following is a list of automated functions performed by your hot tub. These functions are listed below in an attempt to suppress any operational concerns you may have during the first 24-hours of ownership! Also listed below are important maintenance recom-mendations you should observe on a regular basis to protect your new investment.

Automated Spa OperationsYour new hot tub is equipped with an automated “blow-out” cycle that clears all plumbing lines daily to promote maximum water sanitation. Each day at 12:00 PM (noon), pump 2, pump 3 (Maxxus Models Only) and the blower will automatically turn on for a period of one minute, then go off. Then pump 1 will turn on and run for one minute to complete the blow-out cycle. Be aware, the factory programmed blow-out cycle cannot be canceled or altered!

Maintain Healthy Spa WaterAlways maintain your hot tub’s water chemistry within the following parameters as defined by the Association of Pool And Spa Professionals:

Always maintain your spa filter as outlined below to ensure healthy spa water. Refer to page 51-52 for additional information.

Required Filter MaintenanceYour new hot tub is equipped with an advanced MicroClean IITM water filtration system that provides unsurpassed water quality! To ensure maximum water quality at all times, you should replace the filter cartridge every six months, or earlier as necessary. The filter cartridge is designed to be thrown away! Attempts to reuse the filter cartridge may result in the re-release of unwanted particles back into the hot tub. See page 51-52 for detailed filter cartridge replacement instructions.

Required Water ReplacementYou should replace the hot tub’s water every 3 to 6 months. The frequency depends on a number of variables including frequency of use, number of users, and attention paid to water quality maintenance. You will know it is time for a change when you cannot control sudsing and/or you can no longer get the normal feel or sparkle to the water, even though the key water balance measurements are all within the proper parameters. See page 56 for additional information.

Page 4: 06880 Eng Man

Table of Contents

1.0 Important Hot Tub Owner Information ......................... 12.0 Important Safety Instructions ........................................ 23.0 Locating Your Sundance Hot Tub ................................. 64.0 General Electrical Safety Instructions .......................... 85.0 Electrical Installation Instructions (240V Service) ...... 86.0 Maxxus Power Requirements ...................................... 127.0 Altamar, Cameo, Capri, Optima, Majesta, Marin Power Requirements .................................................... 138.0 Hot Tub Fill Up Procedure ........................................... 149.0 Hot Tub Features (All Models) ..................................... 18 10.0 Operating Instructions ................................................ 2710.1 View Button..................................................................... 2710.2 Light Button (Main Control Panel) .................................. 2710.3 AquaTerraceTM Light Control ........................................... 2710.4 Air Injection ..................................................................... 28 10.5 Activate Jets Pump 1 ...................................................... 2810.6 Activate Jets Pump 2/Pump 3 ........................................ 2810.7 Selecting The Desired Massage Action .......................... 2810.8 Adjusting Fluidix Intelli-Jets ............................................ 2910.9 Air Controls ..................................................................... 2910.10 Waterfall Control ............................................................. 3010.11 Fragrance Dispenser ...................................................... 3010.12 Optional SunSound Audio System ................................. 3010.13 Maxxus Massage/Waterfall Selector Diagram ................ 3110.14 Maxxus Air Controls Diagram ......................................... 3210.15 Optima Massage/Waterfall Selector Diagram ................ 3310.16 Optima Air Controls Diagram .......................................... 3410.17 Cameo Massage/Waterfall Selector Diagram ................ 3510.18 Cameo Air Controls Diagram .......................................... 3610.19 Majesta Massage/Waterfall Selector Diagram ............... 3710.20 Majesta Air Controls Diagram ......................................... 3810.21 Altamar Massage/Waterfall Selector Diagram ................ 3910.22 Altamar Air Controls Diagram ......................................... 4010.23 Marin Massage/Waterfall Selector Diagram ................... 4110.24 Marin Air Controls Diagram ............................................ 4210.25 Capri Massage/Waterfall Selector Diagram ................... 4310.26 Capri Air Controls Diagram ............................................. 44

Page 5: 06880 Eng Man

11.0 Heating Modes ..................................................................4511.1 Standard Mode ...................................................................4511.2 Economy Mode ...................................................................4511.3 Selecting Standard or Economy Filter Mode ......................4511.4 Clean-Up “Blow-Out” Cycle ................................................45

12.0 Programming Instructions ...............................................4612.1 Programming Filter/Circulation Pump Run Time ................4612.2 Programming Filter Cycles .................................................4612.3 Adjusting The Time of Day .................................................4812.4 Main Control Panel Lock ....................................................4812.5 Locking Filter Cycles ..........................................................4912.6 Temperature Setting Lock ...................................................4912.7 Programming The Change Filter Reminder .......................49

13.0 Hot Tub Maintenance .......................................................5113.1 Replacing the Filter Cartridge .............................................5113.2 Draining and Refilling .........................................................5213.3 Cleaning the Hot Tub Interior .............................................5313.4 Pillow Care .........................................................................5413.5 Maintaining the Synthetic Cabinet ......................................5413.6 Maintaining the Cover ........................................................5413.7 Winterizing ..........................................................................5513.8 Restarting your Hot Tub in Cold Weather ..........................56

14.0 Water Quality Maintenance ..............................................5614.1 pH Control ..........................................................................5614.2 Sanitizing ............................................................................5614.3 Other Additives ...................................................................5714.4 Optional Ozone Water Maintenance System .....................5714.5 Handrail Maintenance .........................................................57

15.0 Troubleshooting - Display Messages .............................5816.0 Troubleshooting - Procedures ........................................6017.0 US/Canada 60Hz Maxxus Electrical Wiring Diagram ....6318.0 US/Canada 60Hz Altamar, Cameo, Capri, Majesta, Optima, Marin Electrical Wiring Diagram .......6419.0 Export 50Hz Maxxus Electrical Wiring Diagram ............6520.0 Typical Spa Wiring Diagrams (US/Canada 60Hz Models) .....................................................................6621.0 Optional SunSound Stereo Receiver Features .............67

Page 6: 06880 Eng Man

Page �

1.0 Important Hot Tub Owner InformationYour Sundance® hot tub is constructed to the highest standards and is capable of providing many years of trouble-free use. However, because heat retentive materials are utilized to insulate the hot tub for efficient operation, an uncovered hot tub surface directly exposed to sunlight and high temperatures for an extended period is subject to permanent damage. Damage caused by exposing the hot tub to this abuse is not covered by warranty. We recommend that you always keep the hot tub full of water when it is exposed to direct sunlight and that you keep the Sundance insulating cover in place at all times when the hot tub is not in use. Read and carefully follow the requirements for your hot tub’s support base found in the section 3.0 titled, “Locating Your Sundance Hot Tub” (page 6) or as prescribed by your authorized Sundance Dealer.

Sundance hot tubs constantly strives to offer the finest hot tubs available, therefore, modifications and enhancements may be made which affect the specifications, illustrations and/or instruc-tions contained herein.

FCC NoticeThis equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part �5 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be deter-mined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

�. Rearrange or relocate the receiving antenna; 2. Increase the separation between the equipment and receiver; 3. Connect the equipment into an outlet on a circuit different from the

circuit connected; 4. Consult the dealer or an experienced radio/TV technician for help.

(Changes or modifications not expressly approved by the party responsible for FCC compliance could void the user’s authority to operate this equipment.)

Page 7: 06880 Eng Man

Page 2

2.0 IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS CAREFULLYWhen installing and using this electrical equipment, basic safety precau-tions should always be followed, including:

�. WARNINg: To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.

2. WARNINg: A grounding wire connector is provided on this unit to connect a minimum No. 8 AWG (8.4mm2) solid copper conductor between this unit and any metal equipment, metal enclosures of electrical equipment, metal water pipe, or conduit within 5 feet (�.5m) of the unit.

3. DANgER: Risk of Accidental Drowning. Extreme caution must be exercised to prevent unauthorized access by children. To avoid acci-dents, ensure that children cannot use this hot tub unless they are supervised at all times.

4. DANgER: Risk of Injury. The suction fittings in this hot tub are sized to match the specific water flow created by the pump. Should the need arise to replace the suction fittings or the pump, be sure that the flow rates are compatible. Never operate the hot tub if the suction fittings are broken or missing. Never replace a suction fitting with one rated less than the flow rate marked on the original suction fitting.

5. DANgER: Risk of Electric Shock. Install at least 5 feet (�.5m), from all metal surfaces. As an alternative, a hot tub may be installed within 5 feet of metal surfaces if each metal surface is permanently con-nected (bonded) by a minimum No. 8 AWG (8.4 mm2) solid copper conductor attached to the wire connector on the grounding lug, inside the equipment compartment on the equipment box.

6. DANgER: Risk of Electric Shock. Do not permit any electrical appli-ance, such as a light, telephone, radio, television, etc. within 5 feet (�.5m) of a hot tub unless such appliances are built-in by the manu-facturer.

7. ELECTRICAL SUPPLY: The electrical supply for this product must include a suitably rated switch or circuit breaker to open all unground-ed supply conductors to comply with section 422-20 of the National Electrical Code, ANSI/NFPA 70. The disconnect must be readily accessible and visible to the hot tub occupant but installed at least 5 feet (�.5m), from the hot tub water.

Page 8: 06880 Eng Man

Page 3

8. WARNINg: To Reduce the Risk of Injury:

9. The water in the hot tub should never exceed �04°F (40°C). Water temperatures between �00°F (38°C) and �04°F (40°C) are consid-ered safe for a healthy adult. Lower water temperatures are recom-mended for young children and when hot tub use may exceed �0 minutes.

�0. Since excessive water temperatures have a high potential for caus-ing fetal damage during the early months of pregnancy, pregnant or possibly pregnant women should limit hot tub water temperatures to

�00°F (38°C). If pregnant, please consult your physician before using a hot tub.

��. Before entering the hot tub, the user should measure the water temperature with an accurate thermometer since the tolerance of

water temperature-regulating devices may vary as much as +/- 5°F (2°C).

�2. The use of alcohol, drugs, or medication before or during hot tub use may lead to unconsciousness with the possibility of drowning.

�3. Persons suffering from obesity or a medical history of heart disease, low or high blood pressure, circulatory system problems, diabetes, infectious diseases or immune deficiency syndromes should consult a physician before using a hot tub. If you experience breathing diffi-culties in association with using or operating your hot tub, discontinue use and consult your physician.

�4. Persons using medication should consult a physician before using a hot tub since some medication may induce drowsiness, while other medication may affect heart rate, blood pressure, and circulation.

�5. Always shower before and after using your hot tub. To reduce the possibility of contracting a waterborne illness, always maintain water chemistry within the parameters listed on the inside cover of this manual. If you or other bathers experience such a condition, discon-tinue use and seek medical attention.

IMPORTANT CSA SAFETY INSTRUCTIONS (CANADA ONLY)When using this electrical equipment, basic safety precautions should always be followed, including the following:

�. READ AND FoLLoW ALL INSTRuCTIoNS.

Page 9: 06880 Eng Man

Page 4

2. A green colored terminal or a terminal marked G, Gr, Ground, Grounding or the symbol* is located inside the supply terminal

box or compartment. To reduce the risk of electric shock, this terminal must be connected to the grounding means provided in the

electric supply service panel with a continuous copper wire equiva-lent in size to the circuit conductors that supply this equipment.

*IEC Publication 4�7, Symbol 50�9.

3. At least two lugs marked “Bonding Lugs” are provided on the external surface or on the inside of the supply terminal box/compartment. To reduce the risk of electric shock, connect the local common bonding grid in the area of the hot tub to these terminals with an insulated or bare copper conductor not smaller than No. 6 AWG.

4. All field-installed metal components such as rails, ladders, drains or other similar hardware within �0 feet (3m) of the hot tub shall be bonded to the equipment grounding buss with copper conductors not smaller than No. 6 AWG.

5. SAVE THESE INSTRUCTIONS.

WARNINg: Children should not use hot tubs without adult supervision.

WARNINg: Do not use hot tubs unless all suction guards are installed to prevent body and hair entrapment.

WARNINg: People with infectious diseases should not use a hot tub.

WARNINg: To avoid injury, exercise care when entering or exiting the hot tub.

WARNINg: Do not use drugs or alcohol before or during the use of a hot tub to avoid unconsciousness and possible drowning.

WARNINg: Pregnant or possibly pregnant women should consult a physician before using a hot tub.

WARNINg: Water temperature in excess of 40 °C (�04 °F) may be injuri-ous to your health.

WARNINg: Before entering the hot tub, measure the water temperature with an accurate thermometer.

WARNINg: Do not use a hot tub immediately following strenuous exercise.

Page 10: 06880 Eng Man

Page 5

WARNINg: Prolonged immersion in a hot tub may be injurious to your health.

WARNINg: Do not permit electric appliances (such as lights, telephone, radio, television, etc.) within 5 feet (�.5m) of this hot tub unless such appliances are built-in by the manufacturer.

CAUTION: Maintain water chemistry in accordance with manufacturer’s instructions.

WARNINg: The use of alcohol or drugs can greatly increase the risk of fatal hyperthermia in hot tubs.

SAVE THESE INSTRUCTIONS

HYPERTHERMIAProlonged immersion in hot water may induce hyperthermia. A descrip-tion of the causes, symptoms, and effects of hyperthermia are as fol-lows:

Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6°F (37°C). The symptoms of hyperthermia include drowsiness, lethargy, and an increase in the internal temperature of the body. The effects of hyperthermia include:

�. unawareness of impending hazard;2. Failure to perceive heat;3. Failure to recognize the need to exit hot tub;4. Physical inability to exit hot tub;5. Fetal damage in pregnant women; and6. unconsciousness and danger of drowning.

A warning sign is provided in your warranty packet. Please install it at a location near your hot tub, where it is visible to the user of the hot tub. For additional or replacement signs please contact your local Sundance Hot tubs dealer and reference item number #6530-082.

CAUTIONS�. Persons suffering from heart disease, diabetes, high or low blood

pressure, and any condition requiring medical treatment, pregnant women, the elderly, or infants should consult with a physician before

Page 11: 06880 Eng Man

Page 6

using a hot tub.2. The Consumer Products Safety Commission has stated that the

water temperature in a hot tub should not exceed �04°F (40°C). Immersion in water in excess of �04°F (40°C) can be hazardous to your health.

3. observe a reasonable time limit when using the hot tub. Long expo-sures at higher temperatures can cause high body temperature. Symptoms may include dizziness, nausea, fainting, drowsiness, and reduced awareness. These effects could possibly result in drown-ing.

4. Do not use the hot tub under the influence of alcohol, narcotics, or other drugs. use of the hot tub under these conditions may lead to serious consequences.

5. Always test the hot tub water temperature before entering the hot tub. Enter and exit the hot tub slowly. Wet surfaces can be very slip-pery.

6. Never bring any electrical appliances into or near the hot tub. Never operate any electrical appliances from inside the hot tub or when you are wet unless such appliances are built-in by the manu-facturer.

7. Proper chemical maintenance of hot tub water is necessary to maintain safe water and prevent possible damage to hot tub components.8. use the straps and clip tie downs to secure the cover when not in

use. This will help to discourage unsupervised children from enter-ing the hot tub and keep the hot tub cover secure in high-wind con-ditions. There is no representation that the cover, clip tie-downs, or

actual locks will prevent access to the hot tub.

3.0 Locating Your Sundance Hot Tub

IMPORTANT: Because of the combined weight of the hot tub, water and users, it is extremely important that the base upon which the hot tub rests be smooth, flat, level and capable of uniformly supporting this weight, without shifting or settling, for the entire time the hot tub is in place. If the hot tub is placed on a surface which does not meet these requirements, damage to the skirt and/or the hot tub shell may result. Damage caused by improper support is not covered under warranty. It is the responsibility of the hot tub owner to assure the integrity of the support at all times.

Page 12: 06880 Eng Man

Page 7

We recommend a poured, reinforced concrete slab with a minimum thickness of 4 inches (�0cm). Wood decking is also acceptable provided it is constructed so that it meets the requirements outlined above.The hot tub must be installed in such a manner as to provide drainage away from the hot tub. Placing the hot tub in a depression without provi-sions for proper drainage could allow rain, overflow and other casual water to flood the equipment and create a wet condition in which it would sit.

For hot tubs which will be recessed into a floor or deck, install in such a way to permit access to the equipment, either from above or below, for servicing. Make certain that there are no obstructions which would pre-vent removal of the cabinet side panels, especially on the side with the equipment bay doors.

In selecting the ideal outdoor location for your hot tub, we suggest that you take into consideration the following: • The proximity to changing area and shelter (especially in regions

subject to cold weather). • The pathway to and from your hot tub (this should be free of debris

so that dirt and leaves are not easily tracked into the hot tub).• The closeness to trees and shrubbery (remember that leaves and

birds could create extra work in keeping the hot tub clean).• A sheltered environment (less wind and weather exposure can

result in lowered operation and maintenance costs).• The overall enhancement of your environment. It is preferable not

to place the hot tub under an unguttered roof overhang since run-off water will shorten the life expectancy of the hot tub cover.

For indoor installations, be certain to make provisions for proper ventilation. When the hot tub is in use, considerable amounts of mois-ture will escape. This can damage certain surfaces over timeIf you have any questions regarding the placement or installation of your hot tub, consult your Sundance Dealer.

WARNINg: In addition to maintenance of filters and water chemistry, proper ventilation is recommended to reduce the risk of exposure to viruses and bacteria that could be present in the air or water. Consult a licensed architect or building contractor to determine your specific needs if installing your hot tub indoors.

Page 13: 06880 Eng Man

Page 8

4.0 general Electrical Safety InstructionsYour new Sundance® hot tub is equipped with the “state-of-the-art” SentryTM equipment system. It contains the most advanced safety and self-protective equipment in the industry. Nonetheless, this hot tub must be installed properly to ensure dependable usage. Please contact your local Sundance dealer or local building department should you have any questions regarding your installation.

Proper grounding is extremely important. Sundance hot tubs are equipped with a current collector system. A pressure wire connector is provided on the surface of the control box, located inside the equip-ment door (Figure-C, Page ��) to permit connection of a bonding wire between this point and any ground metal equipment, metal water pipe or conduit within 5 feet (�.5m) of the hot tub, or copper clad grounding rod buried within 5 feet (�.5m) of the hot tub. Bonding wire must be at least No. 8 AWG (8.4mm2) solid copper wire. This is a most important safety assurance feature.

Before installing your hot tub, check with your local building department to ensure installation conforms to local building codes.

5.0 Electrical Installation Instructions (240V Service)

IMPORTANT NOTICE: The electrical wiring of this hot tub must meet the requirements of the National Electrical Code (NEC) and any appli-cable state or local codes. The electrical circuit must be installed by a qualified electrician and approved by a local building/electrical inspec-tion authority.

�. This hot tub must be permanently connected (hard-wired) to the power supply. No plug-in connections or extension cords are to be used in conjunction with the operation of this hot tub. Supplying power to the hot tub which is not in accordance with these instructions will void both the independent testing agency listing and the manufacturer’s warranty.

2. The power supplied to this hot tub must be a dedicated circuit with no other appliances or lights sharing the power provided by the circuit.

3. To determine the current, voltage and wire size required, refer to section 6.0-7.0 “Power Requirements” (page �2-�3) for your specific

Page 14: 06880 Eng Man

Page 9

hot tub model.

• Wire size must be appropriate per NEC and/or local codes.• We recommend type THHN wire.• All wiring must be copper to ensure proper connections. Do not

use aluminum wire.• When using wire larger than #6, add a junction box near the hot tub

and reduce to short lengths of #6 wire to connect to the hot tub.

4. The electrical supply for this product must include a suitably rated switch or circuit breaker to open all ungrounded supply conduc-tors to comply with Section 422-20 of the National Electrical Code, ANSI/NFPA 70. The disconnecting means must be readily acces-sible to the hot tub’s occupant but installed at least 5 feet (�.5m) from hot tub water.

5. The electrical circuit supplied for the hot tub must include a suitable ground fault circuit interrupter (GFCI) as required by NEC Article 680-42.

6. To gain access to the hot tub’s power terminal block, remove the four screws securing the center cabinet panel on the side of the hot tub under the controls. Then remove the four control box door screws and door (Figure-C, page ��).

7. Select the power supply entrance you want to use (Figures A-B, page �0) and remove the short cabinet panel from the front of the hot tub to allow you to feed the cable through to the control box. Install the cable with connector through the large opening provided in the bottom of the control box.

8. Connect wires, color to color, on terminal blocks TB� and TB3 (Figure-D, page ��). TIGHTEN SECuRELY! All wires must be hooked up securely or damage could result.

9. Install control box door and reinstall the cabinet side panels.

Page 15: 06880 Eng Man

Page �0

Figure-A (Maxxus Equipment Area)

�. Sentry Control Box2. Power Supply Entrance(s)3. Jets Pump #�4. Jets Pump #25. Jets Pump #36. Blower7. Heater

8. Hot Tub Drain (Removable External Drain Cap)9. Pump Drain Plug(s)�0. Filter/Circulation Pump��. optional Subwoofer Behind Bulkhead (Models with Audio option only.)

53

4

SENTRYSPA CONROLLER

1

11

99

102 2

8

7

6

�. Sentry Control Box 2. Power Supply Entrance(s) 3. Jets Pump #� 4. Heater5. Hot Tub Drain (Removable External Drain Cap)6. Air Blower

7. Pump Drain Plug(s)8. Jets Pump #29. Filter/Circulation Pump�0. optional Subwoofer Behind Bulkhead (Models with Audio option only.)

SPA CONROLLER

Note: Pump Locations Vary by Model

8

1

77

10 9

4

62 2

5

3

Figure-B (Equipment Area for All Models Except Maxxus)

Page 16: 06880 Eng Man

Page ��

TB1

Red (L2)

Green

Black (L1)

TB1

TB3

1. Terminal Block2. Bonding Lug3. Receptacle for Optional Ozone Purification System4. Grounding Terminal

SENTRYSPA CONROLLER

1

3

4 2

Figure-C Sentry Control Box

Figure-DTerminal Block 240V

Wire Connection

Page 17: 06880 Eng Man

Page �2

6.0 Maxxus Power RequirementsSundance® hot tubs are designed to provide optimum performance and flexibility of use when connected to their maximum electrical service. However, they are shipped factory configured for their most common preferred electrical connection as follows:

• uS/Canada 60Hz Model: 240VAC/60A• Export 50Hz Model: 230VAC/45A

If you prefer, your Sundance dealer can perform a minor circuit board modification that allows the hot tub to operate on a different electrical service (see Table below).

US/Canada 60Hz Maxxus

US/Canada 60Hz ModelVoltage 240VAC 240VACMax. Current Draw 38A 48ANumber of Wires 3 3Circuit Breaker (2-Pole) 50A** 60A***

** In this configuration, the heater will not operate while any two jets pumps are running.*** In this configuration the heater will operate while any two jets pumps and the blower are running but will not operate when all three jets pumps are running.

Export 50Hz Maxxus

Voltage 230VAC 230VACMax. Current Draw 34A 42ANumber of Wires 3 3Circuit Breaker (2-Pole) 45A** 50A***

** In this configuration, the heater will not operate while any two jets pumps are running.*** In this configuration the heater will operate while any two jets pumps and the blower are running but will not operate when all three jets pumps are running.

Page 18: 06880 Eng Man

Page 13

7.0 Altamar, Cameo, Capri, Marin, Majesta, Optima Power RequirementsSundance® hot tubs are designed to provide optimum performance and flexibility of use when connected to their maximum electrical service. However, they are shipped factory configured for their most common preferred electrical connection as follows:

• All US/Canada 60Hz Models: 240VAC/50A**

If you prefer, your Sundance dealer can perform a minor circuit board modification that allows the hot tub to operate on a different electrical service (see table below).a

US/Canada 60Hz Altamar, Cameo, Capri, Marin, Majesta, Optima

60Hz Altamar, Cameo, Marin, Majesta, Optima ModelsVoltage 240VAC 240VAC 240VACMax. Current Draw 26A 40A 48ANumber of Wires 3 3 3Circuit Breaker (2-Pole) 40A* 50A** 60A***

* In this configuration, the heater will not operate while either jets pump is running or when the blower is running.

** In this configuration, the heater will not operate while both jets pumps are running in high speed.

*** In this configuration the heater will operate while both jets pumps and the blower are running.

60Hz Capri ModelsVoltage 240VAC 240VAC N/AMax. Current Draw 26A 40A N/ANumber of Wires 3 3 N/ACircuit Breaker (2-Pole) 40A* 50A** N/A

* In this configuration, the heater will not operate while either jets pump is running or when the blower is running.

** In this configuration, the heater will not operate while both jets pumps are running in high speed.

Page 19: 06880 Eng Man

Page �4

8.0 Hot Tub Fill Up ProcedureFoR BEST RESuLTS, READ EACH STEP IN ITS ENTIRETY BEFoRE PRoCEEDING WITH THAT STEP.

1. Prepare The Hot Tub For Filling• Clear all debris from the hot tub. (Although the hot tub shell has

been polished at the factory, you may want to treat it with a specially formulated hot tub cleaner. Consult your dealer for

additional information prior to filling hot tub.• Remove filter lid (Figure G-M, page 20-26), then remove filter cartridge from filter bucket as illustrated in section �3.� (pg. 5�).

2. Fill Hot Tub• Place the end of your garden hose into the empty filter bucket.

CAUTION: Never fill with water from a water softener. If your water is extremely “hard”, it is preferable to fill half-way with hard water and the rest of the way with softened water. or, you may fill entirely with hard water if you use a special water additive available from your Sundance dealer.

• Fill hot tub with clean tap water from garden hose until water covers all jets but does not touch the bottom of the lowest headrest (Do NoT oVERFILL!)

IMPORTANT: Always fill your hot tub through the filter bucket after draining. Failure to do so may cause air to be trapped in either pump, preventing the pump from circulating water. Remove the hose and replace the filter cartridge as illustrated in section �3.� (page 5�).

3. Turn On Power Turn on power to hot tub at the home’s circuit breaker. The heater

and filter/circulation pump will automatically activate. If the control panel LCD flashes water temperature and “CooL” or “ICE”, refer to page 58-59 for additional information.

4. Activate Jets Pump 1 Depress the JETS � button on the control panel once to

activate jets pump #�.

Page 20: 06880 Eng Man

Page �5

5. Add Start-Up Chemicals Add the hot tub water chemicals as recommended by your Sundance Dealer. See section titled “WATER QuALITY

MAINTENANCE” (page 56) for general guidance.

6. Establish A Stable Sanitizer Reading Establish a stable sanitizer reading between 3 ppm and 5 ppm chlo-

rine or 4 ppm and 6 ppm bromine. To ensure healthy water condi-tions, always maintain a constant sanitizer reading within the levels recommended by the Association of Pool And Spa Professionals printed on the inside cover of this manual. If sanitizer levels cannot be stabilized, perform the decontamination procedure steps 9-�5 on the following page. Note: the “decontamination procedure” steps

9-15 should also be used after the hot tub has been “Winterized” (sec. 13.7) or has been sitting without power for an extended period.

7. Set Hot Tub To Heat To warm hot tub water to a comfortable temperature, follow these

steps:• The LCD display on the control panel displays the actual

temperature of the hot tub water. Press either the CooLER (Down) or WARMER (up) button once to display the “set”

temperature for 5 seconds. If you want the water to heat to a different temperature, simply press CooLER or WARMER

within 5 seconds. The set temperature increases or decreases by one degree each time one of these buttons is pressed.

• The heater will turn off when the temperature corresponding to the thermostat setting is achieved.

Important Heater Details:• The maximum temperature for which the hot tub can be set is �04°F (40°C) and the minimum is 80°F (27°C). • For Altamar, Cameo, Capri, optima, Majesta, and Marin hot tubs powered with a 40 amp service, turn off jets pump #� and jets pump #2 to operate heater.• Setting the thermostat at maximum will not accelerate the heating process. This will only result in a higher ultimate temperature.• The heater operates until the water reaches the programmed “set temperature”, then turns off. The heater will reactivate after the water cools to approximately �.5° below the “set temperature.”

Page 21: 06880 Eng Man

Page �6

8. Place Cover On Hot Tub• Keeping the insulating cover in place anytime the hot tub is not

in use will reduce the time required for heating, thereby minimizing operating costs.

• The time required for initial heat-up will vary depending on the starting water temperature.

DANgER: Risk of injury, always check water temperature carefully before entering hot tub!

Decontamination Procedure (Steps 9-15)Steps 9-�5 below are only required when sanitizer levels are unstable after performing steps �-6 above. Disregard steps 9-�5 below if sanitizer levels remain stable at 3 ppm to 5 ppm after performing steps �-6 above.

9. Add 2.5 ounces of Sodium Dichlor for every �00 gallons of water. Refer to the table below for approximate water fill volume by model.

CAUTION: Never add chlorine tablets (trichlor) to your hot tub for any reason! This chemical may damage components within your hot tub and void the manufacturer warranty.

Water Fill Volume by ModelHot Tub Model Approximate Fill VolumeAltamar 385 uS Gallons (�,457 Liters)Cameo ....................................... 450 uS Gallons (�,703 Liters)Capri .......................................... 2�5 uS Gallons (8�4 Liters)Majesta ...................................... 375 uS Gallons (�,420 Liters)Marin .......................................... 3�0 uS Gallons (�,�73 Liters)Maxxus ...................................... 580 uS Gallons (2,�96 Liters)optima ....................................... 485 uS Gallons (�,836 Liters)

�0. Leave hot tub cover open during this step to allow excessive chemi-cal vapors to exit hot tub, protecting pillows and plastic knobs from chemical attack. If hot tub is indoors, open doors and windows for proper ventilation. Turn on all hot tub jets pumps for one hour, open all air controls, turn on the blower, and place all massage selector knob(s) in their cen-ter “combo” position as shown (right). Note: You will

Page 22: 06880 Eng Man

Page �7

need to press the jets pump button(s) and blower button every 20 minutes since these functions have an automatic 20 minute time-out function that turns them off.

CAUTION: Never leave your hot tub unattended for any reason while the cover is open and accessible to small children and animals!

��. Turn off power to the hot tub at the circuit breaker, then drain tub as outlined in section �3.2 (page 52).

12. Refill hot tub with clean tap water from garden hose until water covers all jets but does not touch the bottom of the lowest headrest (Do NoT oVERFILL!)

CAUTION: Never fill with water from a water softener. If your water is extremely “hard”, it is preferable to fill half-way with hard water and the rest of the way with softened water. or, you may fill entirely with hard water if you use a special water additive available from your Sundance dealer.

�3. Consult your authorized Sundance dealer for chemical recommen-dations, then add chemicals to hot tub water to achieve a constant sanitizer reading within the levels recommended by the Association of Pool And Spa Professionals printed on the inside cover of this manual.

�4. Turn on all jet pumps and the blower when adding chemicals to ensure proper mixing and leave your hot tub cover open until the sanitizer level falls below 5 ppm to protect pillows and plastic knobs from chemical attack.

CAUTION: Never leave your hot tub unattended for any rea-son while the cover is open and accessible to small children and animals!

CAUTION: To prevent the unlikely possibility of contracting a waterborne illness, maintain water chemistry within step 6 parameters. If you or other bathers experience such a condition, discontinue use and seek medical attention.

Page 23: 06880 Eng Man

Page �8

These display temperature setting and increase or decrease temperature setting and other programmable features.

Select

Cycle

Mode

Display

Figure - E (LCD screen functions

shown below)

Controls the air blower (on, off)

Controls Jets Pump �

Controls Jets Pump #2 (and Maxxus Jets Pump #3).

Accesses filter cycle program mode and advances display to next cycle.

Scrolls menu through filter cycle program-ming features.

Displays time of day and initiates time setting and locking functions.

Figure - D (Main Control Panel Functions)

Inverts main 4-digit display.

Switches between standard and economy modes (page 45).

�5. Establish a sanitizer reading between 3 ppm and 5 ppm chlorine or 4 ppm and 6 ppm bromine, then allow the hot tub to set undisturbed for 8 hours. Retest water after 8 hours to determine if sanitizer levels are stable. If sanitizer levels are stable, your hot tub is ready for use. To ensure healthy water conditions, always maintain a con-stant sanitizer reading within the levels recommended by the

Association of Pool And Spa Professionals printed on the inside cover of this manual. If sanitizer levels are not stable at this time, it will be necessary to repeat this procedure in its entirety (steps �-�5) until stable sanitizer readings are achieved.

9.0 Hot Tub Features (All Models)

Controls hot tub footwell and waterfall light (see page 27).

Page 24: 06880 Eng Man

Page �9

Changes AquaTerrace waterfall and footwell light modes as follows: Random - Freeze Current Color - Red, Purple, Blue, Teal, Green, Amber, White. Press button once for random mode; press a second time to freeze random color; press a third time to select one of seven solid colors. See section �0.2-�0.3 (page 27) for additional information.

Figure - F (AquaTerraceTM Waterfall/Footwell Light Control)

Indicates panel, set temperature or filter cycle programming locked.

Indicates filter cycle in progress or displays cycle programming features (page 46-47).

Indicates jets pump #2 (and Maxxus jets pump #3) is on.

Indicates jets pump #� is on.

Indicates air injection sys-tem (blower) is turned on.

Indicates hot tub light is turned on.

These characters identify what is being shown on the main 4-digit display Indicates operating

mode selected (page 45).

Indicates heater is on (page �5)

Indicates optional ozone generator is on.

Indicates pro-grammed filter cleaning interval has elapsed (page 49).

Figure - E (LCD Screen Functions)

Turns on and changes footwell light intensity asfollows: High - Med - Low - off

Turns on and changes water-fall light intensity as follows: High - Med - Low - off

Page 25: 06880 Eng Man

Page 20

1. Main Control Panel2. Handrails (2 ea.)3. Lights (2 ea.)4. Pillows (4 ea.)5. Euro Jets (6 ea.)6. Fluidix Intelli-Jets (7 ea.)7. Air Controls (8 ea.)8. Whirlpool Jets (4 ea.)9. Gravity Drain10. Massage Selectors (2 ea.)11. Air Injectors (14 ea.)12. Footwell Suction Covers (5 ea.)13. Accu-Pressure Jets (12 ea.)14. Weir Gate/Skimmer15. Filter Lid (The Filter Cartridge And

Suction Fitting/Filter Are Located Under The Filter Lid. The Suction Fitting

Figure - G (Maxxus Hot Tub Features)

Filter Requires Periodic Cleaning For Optimum Performance).

16. AquaTerrace Waterfall Control Valve17. AquaTerrrace Waterfall Filtration

Return18. Fluidix ST Jets (12 ea.)19. AquaTerrace Waterfalls (2 ea.)20. Fluidix ST Jets (6 ea.)21. AquaTerrace Waterfall/Footwell Light

Control22. Optional Audio System Speakers (2 ea.)23. Optional Audio System Receiver24. Pulsator Jets (6 ea.)25. Sunscents Dispenser26. Vortex Jets (2 ea.)

ee

Select

Cycle

Mode

Display

11

11

11

1111

11

11

11

1111

2424

24

24 24

24

11

11

66

5

4 4

44

1

7

10

10

7

7

7 7

7

7

7

5 5

12

12

12

12

12

9

8

8

8

8

26 26

1818

1818

18

18

18

19 19

21

20

20

20

16

3

3

22 22

11

1313

13

11

1313

13 13

1514

17

22

23

25

Spa features subject to change without notice.

Page 26: 06880 Eng Man

Page 21

Figure - H (Optima Hot Tub Features)

1. Main Control Panel2. Handrails (2 ea.)3. Light4. Pillows (4 ea.)5. Euro Jets (4 ea.)6. Fluidix Intelli-Jets (7 ea.)7. Air Controls (5 ea.)8. Whirlpool Jets (2 ea.)9. Gravity Drain10. Massage Selectors (2 ea.)11. Air Injectors (14 ea.)12. Footwell Suction Covers (3 ea.)13. Accu-Pressure Jets (12 ea.)14. Weir Gate/Skimmer15. Filter Lid (The Filter Cartridge And

Suction Fitting/Filter Are Located Under The Filter Lid. The Suction Fitting

Filter Requires Periodic Cleaning For Optimum Performance).

16. AquaTerrace Waterfall Control Valve17. AquaTerrace Waterfall Filtration

Return18. Fluidix ST Jets (12 ea.)19. AquaTerrace Waterfall20. AquaTerrace Waterfall/Footwell Light

Control21. Optional Audio System Speakers (2 ea.)22. Optional Audio System Receiver23. Sunscents Dispenser24. Vortex Jets (2 ea.)

ee

Select

Cycle

Mode

Display

4

1 22

4

4

21

21

4

2

3

6

6

6

24

5

55

2

711

12

12

12

11

11

11

11

11

11

11

11

11

11

11

11

11

7

7

7

7

8

8

9

10

16 10

6

1313

13

13

1313

13 13

14 15

23

17

18

18

18

19

1818

18

20

Spa features subject to change without notice.

Page 27: 06880 Eng Man

Page 22

Figure - I (Cameo Hot Tub Features)

7 1619

10 7

4 4

4

7

10

21

7

14 15

7

1 22

23

68

11

5

5

18

11

11

12

12 17

12

11

5

524

611

11

20

2

2

8 8

1111

139

13

3

11

11

11

11

25

25

6

65

6

6

11

188

1818

1818

18

11

ee

Select

Cycle

Mode

Display

21

1. Control Panel2. Handrails (2 ea.)3. Light4. Pillows (3 ea.)5. Euro Jets (6 ea.)6. Fluidix Intelli-Jets (8 ea.)7. Air Controls (5 ea.)8. Whirlpool Jets (5 ea.)9. Gravity Drain10. Massage Selectors (2 ea.)11. Air Injectors (14 ea.)12. Footwell Suction Covers (3 ea.) 13. Accu-Pressure Jets (2 ea.)14. Weir Gate/Skimmer15. Filter Lid (The Filter Cartridge And

Suction Fitting/Filter Are Located Under The Filter Lid. The Suction Fitting

Filter Requires Periodic Cleaning For Optimum Performance).

16. AquaTerrace Waterfall Control Valve17. AquaTerrace Waterfall Filtration

Return18. Fluidix ST Jets (12 ea.)19. AquaTerrace Waterfall20. AquaTerrace Waterfall Light Control21. Optional Audio System Speakers (2

ea.)22. Optional Audio System Receiver23. Sunscents Dispenser24. Vortex Jets (2 ea.)25. Pulsator Jets (2 ea.)

Spa features subject to change without notice.

Page 28: 06880 Eng Man

Page 23

Figure - J (Majesta Hot Tub Features)

18

18 1818

18

18

18

5

5

11

11

86

11

11

23

11

11

11

9

11

6

12

11

11

18

3

2

21

7

11

12

7

1415

13

13

1313

24

11

11

11

18

18

18

18

5

5

44

19

17

77 16

20

7

10

4

21

22

1

1. Control Panel2. Handrail3. Light4. Pillows (3 ea.)5. Euro Jets (4 ea.)6. Fluidix Intelli-Jets (3 ea.)7. Air Controls (5 ea.)8. Whirlpool Jets (1 ea.)9. Gravity Drain10. Massage Selectors (1 ea.)11. Air Injectors (14 ea.)12. Footwell Suction Covers (3 ea.)13. Accu-Pressure Jets (4 ea.)14. Weir Gate/Skimmer15. Filter Lid (The Filter Cartridge And Suc-

tion Fitting/Filter Are Located Under The Filter Lid. The Suction Fitting Requires

Periodic Cleaning for Optimum Perfor-mance).

16. AquaTerrace Waterfall Control Valve17. AquaTerrace Waterfall Filtration Return18. Fluidix ST Jets (20 ea.)19. AquaTerrace Waterfall20. AquaTerrace Waterfall Light Control21. Optional Audio System Speakers (2 ea.)22. Sunscents Dispenser23. Vortex Jets (2 ea.)24. Pro-Touch II Jets (1 ea.)

Spa features subject to change without notice.

Page 29: 06880 Eng Man

Page 24

Figure - K (Altamar Hot Tub Features)

1. Control Panel2. Handrail3. Light4. Pillows (3 ea.)5. Euro Jets (4 ea.)6. Fluidix ST Jets (12 ea.)7. Air Controls (5 ea.)8. Gravity Drain9. Massage Selector (1 ea.)10. Air Injectors (14 ea.)11. Footwell Suction Covers (3 ea.)12. FluidixReflexJets(6ea.)13. Pulsator Jets (2 ea.)14. Fluidix Intelli-Jets (4 ea.)15. Vortex Jets (2 ea.)16. Weir Gate/Skimmer17. Filter Lid (The Filter Cartridge And

Suction Fitting/Filter Are Located Under The Filter Lid. The Suction Fitting Requires Periodic Cleaning for Optimum Performance).

18. AquaTerrace Waterfall Control Valve19. AquaTerrace Waterfall Filtration Return20. AquaTerrace Waterfall21. Sunscents Dispenser22. Whirlpool Jets (3 ea.)23. AquaTerrace Light Control Panel24. Optional Audio System Speakers (2 ea.)

ne

ee

Select

Cycle

Mode

Display

12 1010

11

11 11

22

10 10

10

9

10

14

15

15

14

14

14

22 6

14 17

7

7

777

8

20

19

13

13 3

18

1

16

23

10

10

10

21

45 5

5 4

4

2

10

24

24

Spa features subject to change without notice.

Page 30: 06880 Eng Man

Page 25

Figure - L (Marin Hot Tub Features)

1. Control Panel2. Handrail3. Light4. Pillows (3 ea.)5. Euro Jets (4 ea.)6. Fluidix ST Jets (10 ea.)7. Air Controls (5 ea.)8. Gravity Drain9. Massage Selectors (1 ea.)10. Air Injectors (12 ea.)11. Footwell Suction Covers (3 ea.)12. FluidixReflexJets(6ea.)13. Pulsator Jets (2 ea.)14. Fluidix Intelli-Jets (5 ea.)15. Vortex Jets (2 ea.)16. Weir Gate/Skimmer17. Filter Lid (The Filter Cartridge And

Suction Fitting/Filter Are Located Under The Filter Lid. The Suction Fitting Requires Periodic Cleaning for Optimum Performance).

18. AquaTerrace Waterfall Control Valve19. AquaTerrace Waterfall Filtration Return20. AquaTerrace Waterfall21. Sunscents Dispenser22. Accu-Pressure Jets (2 ea.)23. AquaTerrace Waterfall Light Control24. Optional Audio System Speakers (2 ea.)

ee

Select

Cycle

Mode

Display

1

23

1416 17

1820

21

5

5

3

8

2

7

9

10

10

10

10

10

11

11

11

10

1212

13

13

14

14

14

15

15

22

1010

10

1010

10

7

77

7

4

4

66

6

44

19

24

24

Spa features subject to change without notice.

Page 31: 06880 Eng Man

Page 26

Figure - M (Capri Hot Tub Features)

1. Control Panel2. Integral Handrail3. Gravity Drain4. Pillows (3 ea.)5. Euro Jets (2 ea.)6. Fluidix ST Jets (10 ea.)7. Air Controls (3 ea.)8. Waterfall Control Valve (1 ea.)9. Light10. Massage Selectors (1 ea.)11. Air Injectors (12 ea.)12. Waterfall Bypass Fitting13. FluidixReflexJets(6ea.)14. Pulsator Jets (2 ea.)15. Fluidix Intelli-Jets (3 ea.)16. Vortex Jet (1 ea.)17. Filter Lid (The Filter Cartridge And

Suction Fitting/Filter Are Located Under The Filter Lid. The Suction Fitting Requires Periodic Cleaning for Optimum Performance).

18. AquaTerrace Waterfall19. SunScents Dispenser20. Footwell Suction Cover (1 ea.)21. AquaTerrace Light Control Panel

ee

Select

Cycle

Mode

Display

187 7

7

1

2

21

13

10

15

3

17

19

8

914

14

11

11

13

12

20

5 66

11

11

11

11

11

11

11

11

15

15

16

44

4

Spa features subject to change without notice.

Page 32: 06880 Eng Man

Page 27

10.0 Operating InstructionsYour Sundance hot tub has a touch-sensitive control panel, massage selector valves and air control knobs located on the top rim of the hot tub (Figures G-M, page 20-26). These controls let you operate many of the special functions of your Sundance hot tub. By familiarizing yourself with the following information, you will be able to gain the full benefit afforded by the various functions of your hot tub.

10.1 View ButtonPressing this button inverts the main four-digit display on the Command Center’s LCD screen to allow easy reading from either inside or outside the hot tub.

10.2 Light Button (Main Control Panel)Pressing the LIGHT button activates both footwell and waterfall lights in random color mode upon startup, both lights quickly advance through all seven colors, then change colors every 4 seconds thereafter. At this time, you can choose one of seven constant colors on the AquaTerrace control panel. Pressing this button a second time turns both lights off. See section 10.3 below for details.

10.3 AquaTerraceTM Light ControlThe AquaTerrace light control panel offers a variety of light settings described below. Note: lights automatically turn off after 1 hour.

The left button turns on, dims, and turns off the waterfall light(s) as shown. The right button turns on, dims, and turns off the footwell light as shown.

The center button selects random modeor one of 7 constant colors on the footwell and waterfalllights. In random mode, press a second time to freeze random color

Right Button Controls The Footwell Light

MED LOW OFFHigh

x1 x2 x3 x4

Footwell

Left Button Controls The Waterfall Light(s)

MED LOW OFFHigh

x1 x2 x3 x4

Waterfall(s)

Center Button Selects Waterfall And Footwell Light Color Mode

FreezeColor Red Purple Blue Teal Amber

RandomColor

x1 x2 x3 x4 x5 x6 x8

White

x9

green

x7

Right Button Controls The Footwell Light

MED LOW OFFHigh

x1 x2 x3 x4

Footwell

Left Button Controls The Waterfall Light(s)

MED LOW OFFHigh

x1 x2 x3 x4

Waterfall(s)

Center Button Selects Waterfall And Footwell Light Color Mode

FreezeColor Red Purple Blue Teal Amber

RandomColor

x1 x2 x3 x4 x5 x6 x8

White

x9

green

x7

Footwell

Waterfall(s)

Page 33: 06880 Eng Man

Page 28

or continue pressing for one of 7 constant colors. If you go past your favorite color, simply continue pressing to restart the color selection sequence. Note: your color selection is stored in memory and will auto-matically recall when is the light is cycled on and off.

10.4 Air InjectionWhen the AIR button is pressed, the air blower forces air through the injectors located in the seats and footwell. The bubbles symbol above the button appears on the LCD when-ever the air blower is on. An electronic timer automatically turns the air blower off 20 minutes after it was turned on. Note: The air blower automatically activates for 1 minute at the start of the clean-up cycle at 12:00 (Noon). This clears the lines of the air injector system to help ensure that all water is exposed to sanitizer. This cycle is non-program-mable.

10.5 Activate Jets Pump 1The button labeled JETS 1 controls jets pump #�. Press once to turn on jets pump #�. Press a second time to turn pump off.

10.6 Activate Jets Pump 2/Pump 3on two pump models, the button labeled JETS 2 controls jets pump #2. Press once to turn on jets pump #2. Press a second time to turn pump off.

on three pump Maxxus models, the button labeled JETS 2 controls both jets pump #2 and jets pump #3 in the following sequence:

A. Press once to turn on jets pump #2.B. Press a second time to turn on jets pump #3.C. Press a third time to turn off jets pump #2.D. Press a fourth time to turn off jets pump #3.

Auto Turn off - Anytime a jet pump has been manually turned on, it will automatically turn off after approximately 20 minutes. If at this time you desire more jet operation you may simply turn the pump(s) back on.

10.7 Selecting The Desired Massage ActionYour Sundance hot tub is equipped to allow you to customize the massage action you desire. Each model incorporates a massage

Page 34: 06880 Eng Man

Page 29

selector(s) that allows you to customize the massage and performance by diverting water between various jet systems. Simply turn massage selector to position A (Combo), B, or C to divert water pressure to various jet groups.

Note: This valve is designed to operate in positions A (Combo), B, and C for optimum performance. It is considered normal for sound levelswithin the valve to vary between positions due to the large amounts of water flowing through it! For optimum filtration benefits, leave the valve in position A when hot tub is covered. Select position B or C for maximum jet performance during hot tub use.

10.8 Adjusting Fluidix Intelli-JetsThe Fluidix Intelli-Jets in your new hot tub offer the advantage of no moving parts and zero maintenance. They can also be adjusted for a high and low impact massage, providing the ultimate massage! Each jet has its own water volume and directional or oscillating flow adjustment. The jet’s outer dial controls water volume (flow rate) and it’s center “mode disk” selects either an oscillating or directional flow massage.

To Adjust Jets�. Turn outer dial (A) clockwise to increase water volume. Turn outer dial counterclockwise to decrease water volume or to shut jet off. 2. Rotate center “mode disk” (B) clockwise to select a non-oscillating water stream or turn counterclock- wise to select an oscillating stream at any angle.3. For a high impact massage, turn corresponding air control knob clockwise. For low impact massage, turn corresponding air control knob counterclockwise. Refer to sections �0.�3-�0.26 (page 3�-44) for specific operation details.

Note: Always keep at least 6 adjustable jets open at all times on each jet system.

10.9 Air ControlsEach jet system has its own air control. These controls allow you to regulate the amount of air which is mixed with the water entering through the jets. Clockwise rotation adds more air and counterclockwise rotation reduces air flow. To minimize heat loss, these controls should be closed when the hot tub is not in use.

A B

BC

A

Page 35: 06880 Eng Man

Page 30

10.10 Waterfall ControlTurn waterfall control valve counterclockwise to increase waterfall(s) output. Turn control valve clockwise to decrease or turn off waterfall(s) output. Note: it takes 4 full revolutions to change the waterfall from a full off to a full on flow rate.

10.11 Fragrance Dispenseron the rim of your hot tub is a screw-off cap labeled “SunScentsTM Fragrance Dispenser” (Page 20-26). It is designed to contain packages of a specially made fragrance available from your Sundance dealer. The fragrance is carried into the hot tub water by the air coming through the injector system when the air blower is on.

CAUTION: To prevent personal injury, always turn off air blower before removing or installing SunScents dispenser cap. use only Sundance SunScents fragrances in your new hot tub. Never remove the SunScents beads from their plastic cage for any reason! Install bead cage directly into SunScents dispenser. Never use this dispenser for any other type of fragrance. Always make certain that the dispenser cap is securely in place before operating the hot tub’s air blower.

10.12 Optional SunSoundTM Audio SystemSundance models with the optional audio system offer enhanced hot tub enjoyment by offering an integrated state-of-the-art audio system. These models include a high-quality AM/FM/CD splash-resistant marine stereo receiver, two high-quality marine speakers, and an integrated sub woof-er for long-life and an excellent sound quality. Two speakers located on the top of the hot tub shell (Figures G-M, page 20-26) are designed for manual extension and retraction. To expose each speaker for audio playback, simply press download on each enclosure to unlatch it’s “pop-up” mechanism, then release. To retract each speaker before covering hot tub, gently press downward on each enclosure until you feel a slight “click”, then release. Refer to section 2�.0 (page 67) for complete ste-reo operation details.

CAUTION: Never step or sit on a speaker enclosure! This type of misuse will damage the speaker enclosure latching and track mecha-nism. Always retract speakers prior to covering hot tub.

Full on

Full oFF

4x

4x

Page 36: 06880 Eng Man

Page 31

10.13 MaxxusTM Massage / Waterfall Selector Diagram

..

Spa operation subject to change without notice.

Page 37: 06880 Eng Man

Page 32

10.14 MaxxusTM Air Controls Diagram

Spa operation subject to change without notice.

Page 38: 06880 Eng Man

Page 33

Massage Selectors (1-2):• Massage Selector #1 Controls Pump #1• Massage Selector #2 Controls Pump #2

Waterfall Selector (2)• Waterfall Selector #3 Controls Waterfall Output.

Continously Powered Jets (3):• Jets #4 Are Always on When Pump #1 is Running.• Jets #5 Are Always on When Pump #2 is Running.

10.15 OptimaTM Massage / Waterfall Selector Diagram

Spa operation subject to change without notice.

Page 39: 06880 Eng Man

Page 34

10.16 OptimaTM Air Controls Diagram

Spa operation subject to change without notice.

Page 40: 06880 Eng Man

Page 35

10.17 CameoTM Massage / Waterfall Selector Diagram

2a

1a

1a

2a

2a2b

1b

1b

1b

1b

1b

Massage Selector OperationRotate Massage Selectors 1 & 2 to Divert Water

Between Designated Jet Groups.

Massage Selectors (1-2):• Massage Selector #1 Controls Pump #1• Massage Selector #2 Controls Pump #2

Waterfall Selector (3):• Waterfall Selector #3 Controls Waterfall Output.

Continuously Powered Jets (4):• Jets #4 Are Always On When Pump #1 is Runnng.

Spa operation subject to change without notice.

Page 41: 06880 Eng Man

Page 36

10.18 CameoTM Air Controls Diagram

Air Control OperationRotate Air Controls 1-5 to Add Air

to Designated Jet Groups.

Spa operation subject to change without notice.

Page 42: 06880 Eng Man

Page 37

10.19 MajestaTM Massage / Waterfall Selector Diagram

3

1a

1b

1b

3

33

2

3

Massage Selector OperationRotate Massage Selector 1 to Divert Water

Between Designate Jet Groups.

Massage Selector (1):• Massage Selector #1 Controls Pump #1

Waterfall Selector (2)• Waterfall Selector #2 Controls Waterfall Output.

Continously Powered Jets (3):• Jets #3 Are Always on When Pump #2 is Running.

Spa operation subject to change without notice.

Page 43: 06880 Eng Man

Page 38

10.20 MajestaTM Air Controls Diagram

3

4

5

2

3

5

4

4

15

1

1

Air Control OperationRotate Air Controls 1-5 to Add Air to

Designated Jet Groups.

Spa operation subject to change without notice.

Page 44: 06880 Eng Man

Page 39

10.21 AltamarTM Massage / Waterfall Selector Diagram

ee

Select

Cycle

Mode

Display

Massage Selector OperationRotate Massage Selector 1 to Divert

Water Between Designated Jet Groups.

Massage Selector (1): • Massage Selector #1 Controls Pump #2.

Waterfall Selector (2):• Waterfall Selector #2 Controls Waterfall.

Continuously Powered Jets• All Unmarked Jets Are Always On When Pump #1 is Running.

2

1a1b

1b

2

Spa operation subject to change without notice.

Page 45: 06880 Eng Man

Page 40

10.22 AltamarTM Air Controls Diagram

n usnt

MT

ec S

S

ee

Select

Cycle

Mode

Display

Air Control OperationRotate Air Controls 1-5 to AddAir to Designated Jet Groups.

11

2

1

5

2

34

2

5

3 4

Spa operation subject to change without notice.

Page 46: 06880 Eng Man

Page 41

10.23 MarinTM Massage / Waterfall Selector Diagram

Massage Selector OperationRotate Massage Selector 1 to Divert Water

Between Designated Jet Groups.

Massage Selector (1):• Massage Selector #1 Controls Pump #1.

Waterfall Selector (2):• Waterfall Selector #2 Controls Waterfall.

Continuously Powered Jets:All Unmarked Jets Are Always On When Pump #2is Running.

1

2

ee

Select

Cycle

Mode

Display

1a

1b

2

1b

1b

Spa operation subject to change without notice.

Page 47: 06880 Eng Man

Page 42

10.24 MarinTM Air Controls Diagram

Air Control OperationRotate Air Controls 1-5 to AddAir to Designated Jet Groups.

ee

Select

Cycle

Mode

Display

1

2

34

5

1

2

5

4

15

3

Spa operation subject to change without notice.

Page 48: 06880 Eng Man

Page 43

10.25 CapriTM Massage / Waterfall Selector Diagram

ee

Select

Cycle

Mode

Display

Massage Selector OperationRotate Massage Selector 1 to Divert Water

Between Designated Jet Groups.

Massage Selector (1):• Massage Selector #1 Controls Pump #1.

Waterfall Selector (2):• Waterfall Selector #2 Controls Waterfall.

1

1a

1b

1b

2

2

Spa operation subject to change without notice.

Page 49: 06880 Eng Man

Page 44

10.26 CapriTM Air Controls Diagram

ee

Select

Cycle

Mode

Display

Air Control OperationRotate Air Controls 1-3 to AddAir to Designated Jet Groups.

1 2

3

3

12

2

Spa operation subject to change without notice.

Page 50: 06880 Eng Man

Page 45

11.0 Heating ModesThe control system in your hot tub activates a programmable “standard” or “economy” mode which effects when the heater operates. Refer to sections 11.1 and 11.2 below for additional information.

11.1 Standard Mode (Factory Default)Standard mode is typically selected by customers in cold climates where heat up times are extended due to lower ambient temperatures. In this mode, water temperature is regulated by the set temperature which acti-vates the heater automatically as needed.

11.2 Economy ModeEconomy mode is typically selected by customers in warm climates where heat up times are minimized due to higher ambient temperatures. In this mode, the water temperature is regulated by the set temperature only when a programmed filter cycle is running, unless in summer logic (page 47).

11.3 Selecting Standard or Economy ModePress the MoDE button to select either “Standard” or “Economy” mode. The control panel’s indicator on the right side of the LCD changes to indicate which mode is selected.

11.4 Clean-Up “Blow-Out” CycleThe clean-up cycle is once per day in both Standard and Economy modes at �2:00 (noon) for two minutes. This is not user programmable. Jets pump 2 (and Maxxus jets pump 3) activate for one minute to circu-late any water in the plumbing. After � minute they both go off and jets pump � turns on, runs for � minute, then shuts off.

Page 51: 06880 Eng Man

Page 46

12.0 Programming Instructions

12.1 Programming Filter/Circulation Pump Run TimeThe Sentry control system allows you to easily adjust two separate aspects of filter/circulation pump operation:

�. The time of day (start time) the filter/circulation pump turns on.2. The length of time (duration) the filter/circulation pump operates.

The factory default start time is �2:00am (midnight). The default duration is 24-hours. To make adjustments, press the button labeled CYCLE five times to enter the filter/circulation pump programming mode. The LCD screen will display ADJUST Circ. At this time the system is ready to accept your changes:

• Press the SELECT button once. The previously programmed start time appears on the LCD display.• Press UP or DOWN buttons to adjust the start time in 30-minute increments.• Press the SELECT buttons to program duration.• Press UP or DOWN buttons to program the duration time in � hour increments.• Press DISPLAY button to save changes and recall the main water temperature display. Note: If no button is pressed within 30 seconds, all changes are recorded and the screen automatically returns to the standard water temperature display.

Note: When the standard mode is selected (sec. 11.3), the filter/circulation pump automatically turns on for a heat call regardless of the pump’s programmed start time and duration.

12.2 Programmable Filter CyclesYour hot tub comes with four 30-minute filter cycles which activate the filter/circulation pump. These cycles are factory programmed to start at 6:00 am, �2:00 (noon), 6:00 pm, and �2:00 (midnight). The control system allows you to easily adjust two separate aspects of each cycle: �) the time of day at which it begins; 2) the duration of the cycle.

Note: When “Standard” mode is selected (sec. 11.3) and the filter/circulation pump is set to the factory default duration of 24-hours (sec. 12.1), each cycle is displayed on the main control panel, when

Page 52: 06880 Eng Man

Page 47

running, but no apparent change of operation will occur. However, when “Economy” mode is selected (sec. 11.3), the heater activates only during a programmed filter cycle.

When in a Summer Logic condition is active (see note below), the filter/circulation pump will turn on for all programmed filter cycles.

Summer Logic: In warm weather, the water temperature in the hot tub may exceed the set temperature. This condition may occur due to heat transference from the filter/circulation pump and jets pumps. If the water temperature is higher than 95°F (35°C) and rises two degrees above the set temperature, a “Summer Logic” condition occurs that deactivates the filter/circulation pump and optional ozonator (if equipped). This safety feature cannot be altered! The filter/circulation pump and ozonator will remain off until the water temperature cools to the set temperature (except between �2am-2am when the filter/circulation pump runs for it’s mandatory 2-hour cycle). To help prevent a “Summer Logic” condition, it may be necessary to reduce filter/circulation pump cycles run times in warm weather.

To make adjustments, first press the CYCLE button to enter the filter cycle programming mode. The LCD screen will display the following in the upper right corner:

ADJUST START TIME FILTER CYCLE

This means the system is ready to accept your changes to the starttime for cycle number one. Simultaneously, the large four-digit display in the center of the screen displays the currently programmed start time for that cycle. At this point, you have four options. You may:

�. Press UP or DOWN button to adjust the start time in increments of 30 minutes.

2. Press CYCLE button to display and adjust each subsequent cycles start time. With each press, the currently programmed status will be shown in the large four digit display. To adjust any displayed value, simply press the UP or DOWN button.

3. Press SELECT button to move down the menu from Start Time to Duration, with each press, the currently programmed duration will be shown in the large four-digit display. Press UP or DOWN button

Page 53: 06880 Eng Man

Page 48

to adjust the duration in increments of �5 minutes.4. Press DISPLAY button to save changes and recall the main water temperature display. Note: If no button is pressed within 30 seconds, all changes are recorded and the screen automatically returns to the standard water temperature display.

When a programmed filter/heating cycle activates, the LCD screen displays the following message:

FILTER CYCLE ON

At any time, you may check the programming of any aspect of any filter/heating cycle by first pressing CYCLE button then moving through the menu by pressing either CYCLE or SELECT button. The program-ming is changed only by pressing UP or DOWN buttons during this process.

12.3 Adjusting Time of DayThe Sentry control system remembers the time of day even in the event of a prolonged power outage. However, it may occasionally be neces-sary to reset the time of day. For example: if you are not in the Pacific Time Zone you will want to reset the time for your own time zone. (The system will automatically adjust to and from daylight savings time.) To accomplish this, press DISPLAY, MODE and DISPLAY button within five seconds each. A number representing the hour will be displayed, followed by AM or PM. The hour will advance or decrease each time UP or DOWN button is pressed within five seconds. Then, press DISPLAY button again to display the minutes. Adjust the minutes as necessaryby pressing UP or DOWN button. After 5 seconds, the display will return to normal and save your settings.

12.4 Main Control Panel LockTo help prevent unauthorized use of your hot tub, the Sentry controls incorporate a unique panel locking system which disables the controls on the panel.

• To Lock The Main Control Panel: Press DISPLAY, MODE, and UP buttons within five seconds each. A padlock symbol will appear on the LCD screen. With the panel LOCKED

Page 54: 06880 Eng Man

Page 49

locked, none of the components can be turned on and the only settings that can be adjusted are the standard and economy filter/heating mode and time of day. All automatic hot tub functions will operate normally.• To unlock Main Control Panel: Press DISPLAY, MODE, and DOWN buttons within five seconds. The “lock” symbol will disappear. All buttons are now active.

12.5 Locking Filter CyclesYou may keep all filter cycle programs from being inadvertently altered by electronically “locking” them.

• To Lock All Filter Cycles: Press CYCLE button, then within 30 seconds, press DISPLAY, MODE and UP buttons within five seconds each. A padlock symbol will appear on the screen.

In this state, the status of the cycle program may be checked, but may not be altered.• To unlock Filter Cycles: Press DISPLAY, MODE

and DOWN buttons within five seconds each.

12.6 Temperature Setting LockThe hot tubs temperature setting can be locked to prevent unauthorized use. When locked, all other hot tub buttons and functions remain undisturbed.

• To Lock Temperature Setting: Press UP or DOWN button to display temperature setting, then immediately press the DISPLAY, MODE, and UP buttons within five seconds each. A padlock symbol will appear on the screen. • To unlock Temperature Setting: Press UP or DOWN button to display temperature setting, then immediately press the DISPLAY, MODE, and DOWN buttons within five seconds. each.

12.7 Programming The Change Filter ReminderYour new hot tub is equipped with a programmable “Change Filter” reminder that appears on the control panel display after a specified number of days. It is designed to remind you to inspect or replace the MicroClean II

LOCKED

LOCKED

LOCKED

LOCKED

LOCKED

CHANgEFILTER

Page 55: 06880 Eng Man

Page 50

filter cartridge on a regular basis but does not affect hot tub operation in any way. Your new hot tub’s MicroClean II filter cartridge is designed as a disposable cartridge and should be replaced (thrown-out) every 6 months to ensure optimum water filtration. The “Change Filter” reminder must be reset at each filter inspection/replacement interval. It offers a selectable range from �0-�20 days or can be disabled (turned off). We recommend an initial setting of �20 days (4 months) to remind you to check your MicroClean II cartridge after your first 4 months of operation. At this time, you can easily determine whether you need to change this interval by visually inspecting the filter cartridge. Note: this reminder must be reset at each filter inspection/replacement interval. Refer to section 13.1 for filter replacement instructions.

Programming Instructions �. Press the CYCLE button 6 times. The main display reads “FIL”

indicating the “Change Filter” display program has been accessed.2. Press SELECT button once to display the currently programmed duration or to view days elapsed since last filter cleaning interval. 3. Press UP or DOWN button to change duration setting as follows: 0 - �0 - 20 - 30 - 40 - 50 - 60 - 70 - 80 - 90 - �00 - ��0 - �20 - oFF4. Press DISPLAY button once to save changes and return to the standard water temperature display. Note: If no button is pressed within 30 seconds, all changes are recorded and the screen auto-

matically returns to the standard water temperature display.

Page 56: 06880 Eng Man

Page 5�

13.0 Hot Tub MaintenanceProper and regular maintenance of your hot tub will help it retain its beauty and performance. Your authorized Sundance Dealer can supply you with all the information, supplies, and accessory products you will need to accomplish this. Your new hot tub is equipped with an advanced MicroClean II filter cartridge. This cartridges utilizes a dynamic flow design that allows it to compress in the center to form a hour-glass shape under normal operating conditions. Note: The degree of filter compression will vary from hot tub to hot tub and is normal for the filter cartridge to straighten out when power to the hot tub is turned off.

13.1 Replacing The Filter CartridgeA programmable “Change Filter” reminder flashes on the control panel display after a specified number days to remind you to inspect and/or replace the MicroClean II filter cartridge. This reminder must be reset at each filter inspection/replacement interval. Refer to section �2.7 (page 49) for additional information and programming details.

Your Sundance hot tub is equipped a high-efficiency MicroClean II filter cartridge under the filter lid (Figures G-M, page 20-26). Debris is filtered by the filter/circulation pump drawing water through this cartridge 24-hours a day, 7 days a week (unless programmed otherwise.) To ensure optimum performance, replace this cartridge every 6 months or as needed. This filter cannot be cleaned and reused and MuST be thrown out after use.

All models include a suction cover filter (#6540-2�3) located directly under the MicroClean II filter cartridge that prevents debris from entering the hot tub plumbing when jets pump � is running. This filter should be cleaned every 2 months. Refer to step B below for cleaning instructions.

ALWAYS TURN POWER TO THE HOT TUB OFF BEFORE REPLACING THE MICROCLEAN II FILTER CARTRIDGE! To accomplish this, refer to the filter replacement procedure on the follow-ing page:

Normal Filter Shapes

Filter/Circulation Pump On

Filter/Circulation Pump Off

CHANgEFILTER

Page 57: 06880 Eng Man

Page 52

Replacement MicroClean II filter cartridges may be purchased from your Sundance dealer. An optional pleated filter cartridge is also available from your Sundance dealer (#6540-488). This filter can be cleaned andreused for up to two years but does not maintain the same water qualityand clarity as the standard MicroClean II cartridge.

13.2 Draining And RefillingAbout every 3 to 6 months, you will should replace the hot tub’s water. The frequency depends on a number of variables including the amount of use, attention paid to water quality maintenance, etc. You will know it is time for a change when you cannot control sudsing and/or you can nolonger get the normal feel or sparkle to the water even though the key water balance measurements are all within the proper parameters.

B

A

C

D

Replace (throw-away) the MicroClean filter cartridge every 6 months, or as needed! DO NOT reuse this cartridge for any reason!

Loosen filter nut (A) to provide clearance, then remove used MicroClean II filter cartridge (steps B-C). Remove suctionfitting filter (D) and clean with mild liquid soap solution and warm water, then reinstallover suction fitting.

TURN POWER TO HOT TUB OFF!

Submerge new filter cartridge in spa and tilt each end upward to remove most of theair bubbles trapped inside the filter.

E

1. Install new filter cartridge, then tighten filter nut until it just touches filter face. DO NOT OVERTIGHTEN!2. Turn power to hot tub back on.

FilterNut

FilterNut

TrappedAir

Bubbles

Replace MicroClean IIcartridge every 6 months, DO NOT Reuse for any reason!

A

B

B

C

AD

A

C

Page 58: 06880 Eng Man

Page 53

CAUTION! READ THIS BEFORE DRAININg: To prevent damage to the hot tub’s components, turn off power to the hot tub at the circuit breaker before draining it. Do not turn the power back on until your hot tub has been refilled. There are certain precautions to keep in mind when draining your hot tub. If it is extremely cold, and the hot tub is outdoors, freezing could occur in the lines or the equipment (see “WINTERIZING” page 55). on the other hand, if it is hot outdoors, do not leave the hot tub’s surface exposed to direct sunlight for long periods.

Draining Procedures: �. Turn off power to hot tub at breaker.2. Locate the 3” gray drain valve cap on side of

the hot tub cabinet. unscrew drain valve cap to expose the underlying male garden hose fitting (fig. A-B).

3. Attach female garden hose end to drain fitting and route opposite end of garden hose away from hot tub (fig. B).

4. Pull outward on garden hose end at drain con-nection (approx. 3/8”) to open drain valve and release water from hot tub (fig. C). Water drains at approximately 3 gallons per minute.

5. After hot tub has drained, close drain valve by pushing inward on garden hose end at drain con-nection until you feel it bottom out. Remove gar-den hose and install gray drain cap before refill-ing hot tub. Note: the gray drain cap cannot be installed until the drain valve is closed. Refer to “Hot Tub Fillup Procedure” (page 14) for recom-mended filling instructions.

13.3 Cleaning The Hot Tub InteriorTo preserve the sheen of your hot tub’s surface, it is crucial that you avoid using abrasive cleaners or cleaners which have adverse chemi-cal effect on the surface. If you are not certain as to the suitability of a particular cleanser, consult your authorized Sundance Dealer. Regardless of the cleanser used, use extreme care to assure that no soap residue is left on the surface. This could cause severe sudsing when the

3/8"

Figure A

Figure B

Figure C

Page 59: 06880 Eng Man

Page 54

hot tub is refilled.

13.4 Pillow CareRemove and clean the headrest pillows as needed with soapy water using a cloth or soft-bristle brush. To maintain water resistance and lus-ter, apply a quality vinyl conditioner once a month.

IMPORTANT: Never attempt to remove the pillows by pulling on them! The pillows utilize a bolt-on design that prohibits removal without tools.

To remove pillows:�. Grasp center pillow insert (A)

with finger tips and gently pry outward from pillow base (C).

2. use a standard screwdriver to loosen and remove mounting bolts (B) from pillow base.

3. Assemble in reverse order after cleaning. Do NoT overtighten pillow mounting bolts!

13.5 Maintaining The Synthetic CabinetThe synthetic cabinet requires little or no maintenance of any kind. To clean, simply wipe cabinet with a clean towel and mild detergent soap solution.

CAUTION: Never spray cabinet with a high pressure garden hose for any reason since this action may induce an electrical short in the hot tub’s electrical equipment.

13.6 Maintaining The Coverusing the Sundance insulating hot tub cover anytime the hot tub is not in use will significantly reduce your operating costs, heat-up time, and maintenance requirements. To prolong the life of the cover, handle it with care and clean it regularly using mild soap and water. Periodic treat-ments with a special conditioner developed for Sundance hot tub covers will help protect against deterioration caused by u.V. rays from the sun. Never allow anyone to stand or sit on the cover, and avoid dragging it across rough surfaces.

Page 60: 06880 Eng Man

Page 55

13.7 WinterizingYour Sundance hot tub is designed to automatically protect itself against freezing when operating properly. During periods of severe freezing temperatures, you should check periodically to be certain that the elec-trical supply to the hot tub has not been interrupted. In extreme, bitter cold weather (less than -20°F) verify the filter/circulation pump is set for 24-hour operation (sec. �2.�, page 46) and that standard mode is selected (sec. ��.3 page 45) to protect the hot tub from freezing.

If you do not intend to use your hot tub, or if there is a prolonged power outage during periods of severe freezing temperatures, it is important that all water be removed from the hot tub and equipment to protect against damage from freezing.

For expert winterization of your hot tub, contact your authorized Sundance Dealer. In emergency situations, damage can be minimized by taking the following steps:

CAUTION: Turn off power to hot tub.

�. Follow the directions on page 53 for draining the hot tub.2. As the water level drops below the seats, use whatever means necessary to get the water out of the recessed seating areas and

into the footwell.3. When the water level ceases to drop, use whatever means available to remove any remaining water from the footwell. 4. Remove the equipment-side cabinet panels and locate the drain

plugs in the front of each pump (Figures A-B page �0). Remove these plugs to allow the water to drain out of the pumps and heater.

(Note: Approximately one to two gallons will be released during this procedure. use a wet/dry vacuum or other means to keep this from flooding the equipment compartment. Replace the drain plugs.5. Loosen hose clamp at bottom of heater (Figures A-B, page �0) and pull hose off of heater fitting (twist the hose back and forth while

pulling downward). Tip hose down and allow to drain, then reinstall hose and clamp.

6. Re-install cabinet side panels and cover hot tub so that no casual moisture can enter into it. Consult your Sundance Dealer if you

have any questions regarding winter use or winterizing.

Page 61: 06880 Eng Man

Page 56

13.8 Restarting Your Hot Tub in Cold WeatherIf you want to start up your hot tub after it has sat empty for a time in freezing temperatures, be aware that the water remaining in certain sec-tions of the piping may still be frozen. This situation will block water flow preventing the hot tub from operating properly and possibly damaging the equipment. We recommend you consult your dealer for guidance

before attempting to restart your hot tub under these conditions.

14.0 Water Quality MaintenanceMaintaining the quality of the water within specified limits will serve to enhance your enjoyment and prolong the life of the hot tub’s equipment. It is a fairly simple task, but it requires regular attention because the water chemistry involved is a balance of several factors. There is no simple formula, and there is no avoiding it. Procrastination in regard to water maintenance will result in poor and potentially unhealthful condi-tions for soaking and even damage to your hot tub investment. For spe-cific guidance on maintaining water quality, consult your AuthorizedSundance Dealer who can recommend appropriate chemical products for sanitizing and maintaining your hot tub.

CAUTION: Never store hot tub chemicals inside the hot tub’s equipment bay.

14.1 pH ControlpH is a measure of relative acidity or alkalinity of water and is measured on a scale of 0 to �4. The midpoint of 7 is said to be neutral, above which is alkaline and below which is acidic. In hot tub water, IT IS VERY IMPoRTANT To MAINTAIN A SLIGHTLY ALKALINE CoNDITIoN oF 7.2 to 7.8. Problems become proportionately severethe further outside of this range the water gets. A low pH will be cor-rosive to metals in the hot tub equipment. A high pH will cause minerals to deposit on the interior surface (scaling). In addition, the ability of the sanitation agents to keep the hot tub clean is severely affected as the pH moves beyond the ideal range. That is why almost all hot tub water test kits contain a measure for pH as well as sanitizer.

14.2 SanitizingTo destroy bacteria and organic compounds in the hot tub water, a sanitizer must be used regularly. Your Sundance hot tub is equipped

Page 62: 06880 Eng Man

Page 57

with the Brominator™, a special compartment built into the floating skimmer gate to hold bromine tablets. By regulating the number of bromine tablets in the Brominator™ you can control the amount of bromine which is actively working in your hot tub water. A bromine resid-ual of 2 to 3 ppm is generally considered desirable. A two-part bromine system or granular chlorine (Dichlor) are also acceptable sanitizers.

IMPORTANT: Do not use chlorine tablets (Trichlor) in your hot tub. This chemical can have an extremely corrosive effect on certain materials in the hot tub. Damage caused by use of this chemical, or improper use of any chemicals, is not covered under the hot tub’s warranty.

14.3 Other AdditivesMany other additives are available for your hot tub. Some are necessary to compensate for out-of-balance water, some aid in cosmetic water treatment and others simply alter the feel or smell of the water. Your Authorized Sundance Dealer can advise you on the use of these additives.

14.4 Optional Ozone Water Maintenance SystemIf you have elected to have your hot tub equipped with the optional Sundance CD ozone water purification system you will find that your water stays fresh and clear with significantly less chemical sanitizer usage. You will also probably be able to go longer between complete hot tub drainings.

14.5 Handrail MaintenanceThe handrails in your Sundance hot tub are manufactured from a high quality 3�6 stainless steel alloy. Many people are familiar with the term “stainless steel” and are surprised to learn that it does indeed rust and corrode in the presence of chloride salts, free chlorine, or sulfide gas-ses. The bad news is the environments that produce these elements are ocean spray, salted highways, chemical treatments added to swim-ming pools and hot tubs, and ground water in numerous coastal areas. The good news is with proper care, your hot tub’s handrails can main-tain their original finish.

If your stainless handrails shows signs of rusting you should:• Wash with fresh water (a good detergent won’t hurt).

Page 63: 06880 Eng Man

Page 58

• Clean with a good car chrome polish.• Wax with an automotive or fiberglass wax.

You should never:• Clean with chlorinated cleaners or scouring powders.• use sand paper, “Scotch Brite”, Brillo pads, or similar abrasive products.• Clean with muratic or hydrochloric acids. Vinegar is ok, but it won’t do much to remove rust.

15.0 Troubleshooting - Display MessagesThere are a number of unique functions designed into your Sundance hot tub to protect it from damage and/or to aid in troubleshooting. Following is a listing of all the possible messages along with their mean-ings:

MESSAGE MEANING overheat Protection (Heater is deactivated, filter/

circulation pump is activated). Water temperature is above acceptable limits. Do not enter the water! Remove hot tub cover to speed cooling. See “Water is too hot” on page 6�. If condition persists, contact your dealer or authorized service center.

If the hot tub water is more than 20 °F cooler than the temperature setpoint, jets pump #� and heater will automatically activate to provide freeze

protection. The hot tub will stay in this mode until the water temperature reaches �5 degrees below the set temperature. No corrective action is neces-sary.

FLoW SWITCH (Heater is deactivated. The fil-ter/circulation may also be deactivated). Proper flow of water is inhibited or a flow switch has mal-functioned. Check for proper water level and for clogged filter (page 5�-52). Contact your dealer or service organization.

*

Page 64: 06880 Eng Man

Page 59

*NOTE: THIS MESSAGE CAN ALSO APPEAR IF THE PUMP HAS NOT REGAINED PRIME AFTER THE HOT TUB HAS BEEN DRAINED AND REFILLED. IF YOU SUSPECT THAT THIS IS THE CASE, SEE THE INSTRUCTIONS ON PAGE 60 UNDER “PUMP DOES NOT OPERATE AND ICON DOES.”

Panel sensors have been pressed too many times in a short period of time. Because this could cause excessive wear on equipment components, panel sensors are temporarily deactivated. Panel sensors

will automatically re-activate if no sensor is pressed for 30 seconds.

Circuit board temperature has exceeded acceptable limit. This message will disappear when the circuit board temperature drops below

acceptable limit. If condition persists, provide shade for equipment side of hot tub.

FREEZE PROTECTION A potential freeze condition has been detected. No action is required. Jets pump(s) operate until the hot tub is out of danger. Note: This error

commonly occurs when the hot tub is first filled because tap water is often very cold.

Communication between the control panel and/or remote control panel and circuit board is faulty. Contact your dealer or service organization.

“WATCHDOG” (hot tub is deactivated) A problem has been detected which could cause damage to the hot tub or its components. Contact

your dealer or service organization.

OPEN SENSOR (heater disabled) OR SHORTED SENSOR (hot tub is deactivated) The high-limit temperature sensor is non-functional. This must be repaired only by a dealer or qualified service

organization.

OPEN OR SHORTED SENSOR (heater disabled) The main sensor is non-functional. This must be repaired only by a dealer or qualified service organization.

Page 65: 06880 Eng Man

Page 60

CLOSED OR SHORTED FLOW SWITCH ON SYSTEM STARTUP (system disabled) Flow switch is non-functional. This must be repaired only by a

dealer or qualified service organization.

16.0Troubleshooting-ProceduresIn the unlikely event your hot tub is not working the way you believe it should, please first review all the installation and operating instructions in this manual and check the message on the panel display; second, if you are still not satisfied it is working properly, please follow the appropriate troubleshooting instructions.

PROBLEM PROCEDURENONE OF THE Check the control panel lights.COMPONENTS 1. If there are letters or symbols displayed on OPERATE (i.e. the screen, refer to the previous section to pump, light) determine the meaning and action required. 2. If nothing appears on the screen: a. Check the household circuit breaker b. Contact you dealer or authorized service center

PUMP DOES Depress “JETS” sensor.NOT OPERATE 1. If no sound is detected or if a “buzzing” sound AND ICON DOES is detected, turn off power to the hot tub and contact your dealer or service center. 2. If motor operates but no water flows to jets: a. Pump may not be properly primed. See instructions below. b. Contact dealer or authorized service center.

PumpPrimingInstructions:1. Turn off power to the hot tub.2. Remove the handle from the massage selector supplied by the pump you are priming.3. Loosen the massage selector’s cap slightly (counterclockwise), listening for the air to seep out.4. Tighten the cap finger-tight, replace the handle and turn the hot tub’s power back on.

Page 66: 06880 Eng Man

Page 6�

Note: This method must be used for the jets pumps because these pumps are not connected to the main filter system in any way.

IMPORTANT: If freezing conditions exist and pump is not operational, take measures to protect the system from freeze damage. See section titled “Winterizing”, page 55.

PooR JET ACTIoN �. Make certain the jets pump is turned on.(see Fig. G-M, page 2. Check position of massage selectors.20-26) 3. open air control for selected jet system. 4. Check for adequate water level. 5. Check for dirty filter (page 5�-52).

WATER IS Too HoT �. Reduce thermostat setting (page �5). 2. Switch hot tub to “Economy” mode to turn heater on only during programmed filter cycles (page 45).

No HEAT �. Check thermostat setting. 2. Keep the cover in place while heating. 3. If “heater on” indicator is lit (Figure-E, Page �9), but no temperature rise is experienced after a reasonable period of time, contact your dealer or authorized service center.

FILTER/CIRCuLATIoN �. Verify filter/circulation pump is PuMP oFF programmed to run 24-hours a day (page 46). 2. Filter/circulation pump cycle canceled by power interruption. Wait 24-hours for hot tub to reset. 3. Hot tub water is warmer than 95°F (35°C) and two degrees warmer than the set temperature. The “Summer Logic” safety feature has activated. See note on page 47 for details.

Page 67: 06880 Eng Man

Page 62

FILTER CARTRIDGE Your new hot tub is equippedLooKS with an advanced CoMPRESSED MicroClean II filter cartridge This cartridges utilizes a

dynamic flow design which allows it to compress in the center to form a hour-glass shape under normal operating conditions. Note: the degree of filter compression will vary from hot tub to hot tub and it is normal for the filter cartridge to straighten out when power to the hot tub is turned off.

Should checking the above steps fail to correct the problem, please call your dealer so that he may arrange service.

Sundance builds the best hot tubs in the industry. Nonetheless, we are always striving to improve the quality and features of our products. Your input as a Sundance hot tub owner is a cherished part of this process. If you have any comments or suggestions, or if you wish to be informed on any new products for your hot tub, please write to us.

CoNGRATuLATIoNS on your good taste and welcome to the happiest and most relaxed family in the world!

Normal Filter Shapes

Filter/Circulation Pump On

Filter/Circulation Pump Off

Page 68: 06880 Eng Man

Page 63

17.0 US/Canada 60Hz Maxxus Electrical Wiring Diagram

SEN

SOR

S80

0 LC

D P

ANEL

240

VAC

, 38A

/ 48

A1

PHA

SE, 6

0 H

z; U

SE M

IN. 6

AW

GC

OPP

ER C

ON

DU

CTO

RS

ON

LY

J4

J8

J2

K8

K14

K6K5

K4K1

K2K3

K7

J1

Z1

J6J7

J3

OPT

ION

S

FLO

W S

WIT

CH

HI -

LIM

IT /

FREE

ZE S

ENSO

R

TRAN

SFO

RM

ERT1

RED

Red

BLU

GR

N/Y

EL

Wht

WhtBl

k

Blk

Blk

Blk

Red

BRN

BLK

Blk

PU

MP

3P

UM

P 1

T92

Pu

mp

2R

elay

HI

Wht

Wht

Blk

Blk

Blk

Wht

PU

MP

2H

I

HI

TB

3

TB2

TB6

TB

1

TB1

GR

N

1

XW

BB

YY

35

68

101

21

2

TEM

PER

ATU

RE

SEN

SOR

To P

ump

2 R

elay

&

Hea

ter R

elay

Fr

om T

B1

From

Con

tact

orKX

-2

From

TB

1

From

C

onta

ctor

KX-2

TB5

TB3

K13

TB4

30A,

25

0VSC

-30

F1

CD

Ozo

nat

or

(Op

tio

nal

)

INTE

RLO

CK

JUM

PER

HE

AT

ER

5.

5 kW

, 240

VA

C

Cir

cula

tio

nP

um

p

Blo

wer

ST

ER

EO

(Op

tio

nal

)

This

dev

ice

com

plie

s w

ith p

art 1

5 of

the

FCC

rule

s. O

pera

tion

is

subj

ect t

o th

e fo

llow

ing

two

cond

ition

s:

1.

This

dev

ice

may

not

cau

se

ha

rmfu

l int

erfe

renc

e.2.

Th

is d

evic

e m

ust a

ccep

t any

inte

rfere

nce

rece

ived

incl

udin

g

inte

rfere

nce

that

may

cau

se

un

desi

red

oper

atio

n.

Po

wer

Su

pp

ly20

A, 2

50V

MD

A20

F2

Max

xus

Co

ntr

ol P

anel

XW

12VA

C O

utpu

t to

Wat

erfa

ll Li

ght/

Foot

wel

l Lig

ht

Con

trolle

r

Wat

erfa

llL

igh

t &

Fo

otw

ell

Lig

ht

Co

ntr

olle

r

12VA

C F

rom

T1

Tra

nsfo

rmer

P1H

P1

H

Z

Z

Z T

T

H

12

2A, 2

50V

FX

Fro

m

TB

1

KX

-3

KX

-1

KX

-2

KX

-4

Fro

mC

onta

ctor

KX

-3

Co

nta

cto

rTo

Xfm

r.

To C

onta

ctor

KX-

1 (2

Wire

s) &

Fus

e FX

(1

Wire

)

Two

Wire

s Fr

om T

B1Z

P1

P2

To 3

0A

Fuse

F1

To F

use

F2 &

Hea

ter

Rel

ay (2

Loc

atio

ns)

P2

Fro

m C

onta

ctor

KX

-2

Page 69: 06880 Eng Man

Page 64

18.0 US/Canada 60Hz Altamar, Cameo, Capri, Majesta Optima, Marin Electrical Wiring Diagram

SEN

SOR

S80

0 LC

D P

ANEL

240

VAC

, 26A

/ 40

A / 4

8A1

PHA

SE, 6

0 H

z; U

SE M

IN. 6

AW

GC

OPP

ER C

ON

DU

CTO

RS

ON

LY

J4

J8

J2

K8K6

K5K7

J1

Z1

J6J7

J3

OPT

ION

S

FLO

W S

WIT

CH

HI -

LIM

IT /

FREE

ZE S

ENSO

R

TRAN

SFO

RM

ERT1

RED

Red

BLU

GR

N/Y

EL

Wht

Wht

Blk

Blk

Blk

Red

BRN

BLK

Blk

PUM

P 1

PUM

P 2

HI

Wht

Blk

Blk

Wht

HI

TB3

TB2

TB6

TB1

TB1

GR

N

1

XW

BB

YY

35

68

101

21

2

TEM

PER

ATU

RE

SEN

SOR

To H

eate

rR

elay

s

From

TB

1

TB5

TB3

K13

TB4

30A,

25

0VSC

-30

F1

UV

or C

DO

zona

tor

(Opt

iona

l)

INTE

RLO

CK

JUM

PER

HEA

TER

5.

5 kW

, 240

VAC

Circ

ulat

ion

Pum

p

Blow

er

STER

EO(O

ptio

nal)

This

dev

ice

com

plie

s w

ith p

art 1

5 of

the

FCC

rule

s. O

pera

tion

is

subj

ect t

o th

e fo

llow

ing

two

cond

ition

s:

1.

This

dev

ice

may

not

cau

se

ha

rmfu

l int

erfe

renc

e.2.

Th

is d

evic

e m

ust a

ccep

t any

inte

rfere

nce

rece

ived

incl

udin

g

inte

rfere

nce

that

may

cau

se

un

desi

red

oper

atio

n.

Pow

er S

uppl

y

Con

trol P

anel

XW

12VA

C O

utpu

t to

Wat

erfa

ll Li

ght/

Foot

wel

l Lig

ht

Con

trolle

r

Wat

erfa

llLig

ht/

Foot

wel

l Lig

ht

Con

trolle

r

12VA

C F

rom

T1

Tra

nsfo

rmer

ZY

ZY

12K1

4

K1K2

K3

Pum

p 2

No

t A

vaila

ble

on

Cap

ri M

od

els

Page 70: 06880 Eng Man

Page 65

19.0 Export 50Hz Maxxus Electrical Wiring Diagram

SEN

SOR

S80

0 LC

D P

ANEL 23

0 VA

C, 3

4A /

42A

, 1-P

hase

, 50

Hz;

USE

MIN

. 6 A

WG

(10m

m2 )

CO

PPER

CO

ND

UC

TOR

S O

NLY

J8J6

J7

J3

OPT

ION

S

FLO

W S

WIT

CH

HI -

LIM

IT /

FREE

ZE S

ENSO

R

TRAN

SFO

RM

ERT1

TB3

TB3

TB4

G

11

11

2TB

2 21

1 2

PUM

P 1

PUM

P 2

PUM

P 3

HI

HI

TEM

PER

ATU

RE

SEN

SOR

TB7

From

TB1

Te

rmin

al B

lock

TB1

TB2

UV

or C

DO

zona

tor

(Opt

iona

l)

HEA

TER

5.

5 kW

, 240

VAC

Circ

ulat

ion

Pum

p

TB5

TB1

2 11

TB6 2 1

12

3

HI

30A,

25

0VSC

-30

F1Fo

r Con

nect

ion

To T

wo

Pow

er S

uppl

ies,

Rem

ove

Thes

e W

ires

And

Con

nect

To

Top

Term

inal

s on

TB2

. Th

en C

onne

ct2n

d Su

pply

To

Botto

m T

B2 T

erm

inal

s.

BLU

(N)

GR

N/Y

EL (G

ND

)

NN

NN

N

LN

N

LL

LL

LL

BRN

(L)

L

L

NN

LN

Red

Red

Blac

k

Blac

k

BB

YY

J4

STER

EO(O

ptio

nal)

Pow

er S

uppl

y

This

equ

ipm

ent w

as te

sted

and

foun

d to

be

fully

com

plia

nt w

ith E

N55

014-

1 (1

997)

, EN

5501

4-2

(199

7), E

N61

000-

3-2

(199

5), E

N61

000-

3-3

(199

5), E

N55

022

Cla

ss B

, and

EN

5008

2-1

(199

2)

Stan

dard

s.

XW

Wat

erfa

llLig

ht/

Foot

wel

l Lig

ht

Con

trolle

r

12VA

C F

rom

T1

Tra

nsfo

rmer

XW12

VAC

Out

put t

oW

ater

fall

Ligh

t/Fo

otw

ell L

ight

C

ontro

ller

NL

Blow

er

To H

eate

rR

elay

ZY

ZY

Max

xus

Con

trol P

anel

JP20

JP19

JP9

1 1 3 5 7 9 1 3 5 7 9 11 13

Page 71: 06880 Eng Man

Page 66

Red (L2)

PigtailNeutral Bus

Ground

TB2

TB1

Black (L1)

Green

MainService

Panelwith

GFCI

2-Pole GFCIBreaker

Ground/Bonding Lug**

2-Pole Circuit Breaker with 2-Wire Grounded Load Connection(3 Wires to Hot Tub, 2-Hot (L1-L2), 1-Ground)

White (N)Black (L1)

Red (L2)

240 VAC

No Load Neutral Wire

Note: service disconnect not shown in this diagram. The control box TB1 terminal position varies between models.

BR

Red (L2)

Red (L2)

PigtailNeutral Bus

Ground

TB2

Black (L1)

Black (L1)

Green

GFCI Sub Panel*

Main Panel*

2-Pole GFCIBreaker

Ground/Bonding Lug**

No Load Neutral Wire

Main Panel with Secondary GFCI Shut-Off Box Using a2-Pole GFCI Breaker with 2-Wire Grounded Connection

(3 Wires to Hot Tub, 2-Hot (L1-L2), 1-Ground)

TB1

White (N)

Green (Ground)

*GFCI Sub Panel commonly used when recommended GFCI does not install in Main Panel.

Note: service disconnect not shown in this diagram. The control box TB1 terminal position varies between models.

BR

B

A

SENTRYSPA CONROLLER

SENTRYSPA CONROLLER

240 VAC

20.0 Typical Hot tub Wiring Diagrams A-B (US/Canada 60 Hz Models Only)

Page 72: 06880 Eng Man

Page 67

21.0 Optional SunSoundTM Stereo Receiver Features

Optional SunSoundTM Stereo Receiver general Controls

A. Power On and Off Make sure hot tub power is turned on, then press power button (3) once to turn on. Press a second time to turn off.

B. Adjusting VolumeRotate volume knob (�) to increase or decrease volume. Current volume setting is briefly indicated on the display (0 to 3�).

C. MutePress mute button (2) once to mute audio output (“Mute” flashes on display). To restore audio output, press mute button a second time, or rotate volume knob.

D. Program SelectionPress source button (4) to cycle through available program sources as follows: Tuner - CD - Tuner. If a source is unavailable (e.g. no CD inserted), that source will not appear on the display.

MUTE

POWER

SOURCE

MRD 60 M A R I N E

INTRO RANDOM REPEAT DISK

LOCAL

SCAN

BAND

SET

TUNE

1 2 3 4 5 6

AUDIO AUTO

TRACKDISC IN

4

21 1920 18 17 16 15 14 13

112

11

2

3

5 6 7 8 9 10

�. Volume up/Down (VoL)2. Mute3. Power on/off4. Source5. Infrared Receiver for Wireless Remote Control6. Preset Buttons � to 67. Front Panel Release Button8. Display9. Clock Set�0. Local

��. Scan�2. Band�3. Tune/Seek up�4. Tune/Seek Down�5. Disc +�6. Auto�7. Disc -�8. CD Repeat�9. CD Random20. Audio2�. CD Intro.

Page 73: 06880 Eng Man

Page 68

E. Adjusting Bass LevelPress audio button (20) until display reads “BAS.” Rotate volume knob to desired setting. A display of “C o” indicates center, -2 to -�2 indicates bass cut, and +2 to +�2 indicates bass boost. Note: unit returns to volume mode if volume control is not rotated for 3 seconds.

F. Adjusting Treble LevelPress audio button (20) until display reads “TRE.” Rotate volume knob to desired setting. A display of “C o” indicates center, -2 to -�2 indicates treble cut, +2 to +�2 indicates treble boost. Note: unit returns to volume mode if volume control is not rotated for 3 seconds.

g. Adjusting BalancePress the audio button (20) until display indicates “BAL.” Rotate volume knob to desired setting. A display of “C o” indicates center, L� to �5 indicates left balance, R� to �5 indicates right balance. Note: unit returns to volume mode if volume control is not rotated for 3 sec-onds.

Optional SunSoundTM Stereo Receiver Operation

A. Adjust FaderPress audio button (20) until display reads “FAD.” Rotate volume knob to desired setting. A display of “C o” indicates center, “R” � to �5 indicates rear fade, “F” � to �5 indicates front fade. Note: unit returns to volume mode if volume control is not rotated for 3 seconds.

B. Display ClockPress set button (9) to toggle display between clock and radio modes. When clock mode is selected, the current time displays whenever the unit is left undisturbed.

C. Set ClockPress and hold set button (9) for 2 seconds until first time digit flashes on display. use tune/seek-up button (�3) or tune/seek-down button (�4) to set hour, noting AM/PM indicator at left. Briefly press set button a second time to select minutes display. Press set button a third time to complete procedure. unit remains in clock mode and displays time after 3 seconds. Note: When power to hot tub is shut off for any reason, the clock will be reset to �2:00 AM.

Page 74: 06880 Eng Man

Page 69

D. Open/Close Front PanelPlace thumb on front panel release button (7) with forefinger below front overhang. Press firmly on release button, then flip panel open by pulling outward at top edge. To close panel, flip panel up and press firmly until you hear an audible click. Keep the front panel closed at all times to prevent water intrusion, except when changing discs. CAuTIoN: never insert wet discs into unit or CD player will be damaged!

E. Radio OperationPress source button (4) to select radio mode. Station frequency is indicated on display. • To Select Band: press band button (�2) to toggle through radio

modes as follows: FM� - FM2 - FM3 - AM� - AM2 - FM�. Each radio band stores up to 6 independent presets, for a total of �8 FM and �2 AM presets.

• To Program Presets: tune in desired radio station, then press and hold desired preset button for at least 2 seconds. ”PX”, where X=preset number, appears at bottom right of the display. Note: When power to hot tub is shut off for any reason, all station presets are reset.

F. Automatically Setting Station PresetsTo automatically set station presets to their next higher stations, press the preset button (� to 6) from which to start programming, then press and hold the auto button (�6) for at least 2 seconds. The current station preset and additional preset memories up to P6 will be reprogrammed with their next higher tunable stations. When the auto preset cycle is complete, the unit will remain in preset scan mode and continue scanning for presets until the auto button (�6) is pressed. To select only the strongest stations, press the local button (�0). All �8 FM and �2 AM presets can be set sequentially by selecting the next band and continuing the operation during auto programming.

g. Seek / Manual TunePress tune/seek-up button (�3) once to automatically tune the next higher station. Press tune/seek-down button (�4) once to automatically tune the next lower station. To manually tune to a specific station frequency, press and hold either tune/seek button for at least 2 seconds. Holding either button down will increase or decrease the displayed frequency manually. When the desired frequency is reached, release the button. The unit remains in manual tune mode for 3

Page 75: 06880 Eng Man

Page 70

seconds after either button is released so you can fine tune the station frequency with additional button presses. Note: After 3 seconds, seek mode is re-enabled.

H. Scan FunctionsSelect any AM or FM band and press scan button (��) to listen to a few seconds of each radio station. The display will flash and the radio will automatically scan to the next higher station, play that station for a few seconds, then scan to the next higher station. To stop scanning and continue listening to the current station, press scan button a second time. Note: the radio remains in scan mode until the scan button is pressed a second time or one of the tune buttons is pressed.

I. Preset Scan FunctionPress the auto button (�6) once to enter scan mode. The next higher preset station will be selected and be played for 3 seconds while the preset number on the display flashes. If you wish to remain on this station, press the auto button (�6) a second time. Note: preset scanning continues unless you press the auto button (�6) or either preset button (P�-P6) to cancel.

J. Local/Distance FunctionPress the local button (�0) to toggle between local and distant station mode. When “LoCAL” is displayed, only the strongest stations will be selected during seek or scan. Note: in the default mode (no LoCAL display), all usable stations will be selected during seek or scan.

K. Changing Tuner Frequency from US to EuropeYour unit is factory set to uS tuning frequency steps. To switch to Europe tuning steps, use the switch on the bottom of the unit. With the unit disconnected from the power source, use a screwdriver to slide the switch to the desired position. Note: power must be removed from the radio, or the reset switch must be pressed before the new frequency mode is activated.

Page 76: 06880 Eng Man

Page 7�

Optional SunSoundTM Stereo Receiver CD Player Operation A. Insert, Play, and Eject a CDopen the front panel and insert a CD into the slot with the CD label facing up. The CD will be drawn inside by the motorized mechanism. Close the front panel. The “DISC IN” symbol on the display indicates that a CD is in the drive. • To play CD: press the source button (4) to change to CD mode. The CD will play. The display shows the current track and play time, and will animate a 3-D rotating disc while the CD is playing. Note: if CD play time is not shown, press clock set button (9) once.• To remove CD: open the front panel and press the CD eject button located under the front panel. Remove CD from drive and close front panel. CAUTION: listen for an audible click to ensure the front panel is closed to prevent water intrusion that could damage your unit.

B. Changing CD Tracks and Music SeekTo advance to the next track, press the tune/seek-up button (�3) once and the track counter will increase one track. When the final track is reached on the CD, play will resume on track #�.• To fast forward through tracks: press and hold the tune/seek-up button (�3) until the track counter displays the desired track, then release the button. • To return to the beginning of the current track: press the tune/ seek-down button (�4). Pressing it a second time within � second will skip back to the previous track.• To rewind the current track: press and hold the tune/seek-down button (�4). The track will quickly rewind until you release the button.

C. Intro Scan, Random, Repeat• Intro Scan Mode: press intro button (2�) to enter intro scan mode. The left side of the display reads “SCN” and the first �0 seconds of each CD track will play continuously until you press the intro button a second time, or press either tune/seek-up button (�3) or tune/seek-down button (�4).• Random Mode: press the random button (�9) to play the CD tracks in random order. The left side of the display reads “RDM” when random mode is enabled.• Repeat Mode: press the repeat button (�8) to repeat the current CD track continuously. The left side of the display reads “RPT” when repeat mode is enabled.

Page 77: 06880 Eng Man

Page 72

Optional SunSoundTM Stereo Receiver Troubleshooting

A. Unit will not turn-onMake sure hot tub power is turned on, then check both harness fuses on back of unit making sure they are the proper ratings: • Yellow memory B+ line (�A fuse); Red ACC line (�0A fuse).• With hot tub power off, use a thin rod to press the reset button located under the front panel.

B. Fogged CDs and LensThis condition may occur when it’s cold. Wipe fogged CDs with a soft cloth. Fogged optical components inside the unit will return to normal operation after an hour in a heated environment.

Wireless Remote Control Five function buttons on your supplied wireless remote (highlighted at right) are inoperable until you install an optional control module in your hot tub (purchased separately). For additional information, contact your authorized Sundance dealer.• usable range �5’ (5m)• Never leave the remote under the hot tub cover for any reason.• Battery Replacement: use Coin Type, CR2025 or equivalent.

Wireless Remote Battery Replacement ProcedureRemove remote from rubber housing, then remove protective adhesive seal from battery door. Depress hook with thumbnail and pull outward on battery door. Replace depleted battery with fresh battery, be sure to note polarity. Install battery door. Replace adhesive seal material, mak-ing sure to cover the entire cover gap (additional seal material included, if required). Replace remote firmly into rubber housing.

Stereo Receiver SpecificationsTunerFM usable sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . �0 dBfFM 50 dB quieting sensitivity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . �5 dBFFM alternate channel selectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 dBFM stereo separation @ �kHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 dBfAM usable sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 uVCD PlayerSampling frequency (8X oversampling) . . . . . . . . . . . . . . . . . . .44.� kHzChannel separation @ � kHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 dbSignal-to-noise ratio. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 dBAFrequency-to-noise response @ ±� dB . . . . . . . . . . . . . . . . . .20-20 kHz

Page 78: 06880 Eng Man

Page 73

AudioMaximum power output (45 watts x 4 channel) . . . . . . . . . . . . . . .180 WContinuous power, 20-20 kHz, 4 ohms, 1% THD . . . . . . . . . . . . . . 18 x 4Bass boost/cut . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10/100±dB/HzTreble boost/cut . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10/10+/-dB/kHz

GeneralNominal power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 .4 VDCAllowable power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 .8-15 .6 VDCCurrent consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<10 AmpSpeaker impedance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8 Ohms

14525 Monte Vista Avenue, Chino, California 91710 / U .S .A .Phone 909 606 7733 | Fax 909 606 0195

6530-395, Rev . B ©2006 Sundance Spas, Inc . Printed in U .S .A .

D .A .L ./03/14/06

The following UL requirements must be observed for all spas with optional stereo components installed.

A. “CAUTION - Risk of Electric Shock. Do not leave compartment door open”;

B. “CAUTION - Risk of Electric Shock. Replace components only with identical components”; and

C. Do not operate the audio/video controls while inside the spa.”

D. “WARNING - Prevent Electrocution. Do not connect any auxiliary components (for example: cable, additional speakers, headphones, additional audio/video

components etc.) to the system.”

E. These units are not provided with an outdoor antennae; when provided, it should be installed in accordance with Article 810 of the National Electric Code, ANSI/NFPA 70.

F. Do not service this product yourself as opening or removing covers may expose you to dangerous voltage or other risk of injury. Refer all servicing to qualified service personnel.

G. When the power supply connections or power supply cord(s) are damage; if water is entering the audio/video compartment or any electrical equipment compartment area; if the protective shields or barriers are showing signs of deterioration; or if there are signs of other potential damage to the unit, turn off the unit and refer to a qualified service personnel.

H. This unit should be subjected to periodic routing maintenance (for example, once every 3 months) to make sure that the unit is operating properly.

P/N: 6530-509, Rev. A