P_2017_00555 Received 29/06/2017
Portable pumps with v ortex impellers ideal f or applicat ions in which thewater or liquid contains concentrat ions of abrasiv es when cloggingproblems can occur.
Head
410 185mm410 185mm
47.4% Eff.
0.0
0.4
0.8
1.2
1.6
2.0
2.4
2.8
3.2
3.6
4.0
4.4
4.8
5.2
5.6
6.0
6.4
6.8
7.2
7.6
8.0
8.4
8.8
9.2
9.6
10.0
[m]
0 2 4 6 8 10 12 14 16 18 20 22 24 26 [l/s]
Impeller
Frequency
Motor
Rated v oltage
-
Rated power
Rated speed
Number of poles
Rated current
400 V50 Hz
2 kW
4
1355 rpm
4.9 A
DP 3069 LT 3~ 410
Motor #
3~
Suction Flange Diameter
DP 3069 LT
DN8 0[3 "]
*DIM ENSION TO ENDS OF GUIDE BARS
REF.L INE
REF.L INE
(TO FURTHEST POINT)
MIN
LE
VE
L
CL
OF
DIS
CH
Weight Pump Stand
kg 51 34
lbs 112 75
2 5 0[9 1 31 6
]
200
[77 8]
100
[315 16
]
7 2[2 1 31 6
]
8 4 2[3 3 18
]
1 4 9[5 78
]
149
[57 8]
149
[57 8]
*264
[*10
3 8]
400
[15
3 4]
2 " GUIDE BARS
3 5 2[1 3 78
]8 5[3 38
]
2 3 9[9 71 6
]
489
[19
1 4]
100
[315 16
]
523
[20
9 16]
5 8 6[2 3 11 6
]
6 3[2 71 6
]
1 1 6[4 91 6
]
14[
9 16]
2 3[78
]
Z-Z
Z Z
Impeller diameter 185 mmNumber of blades 6
D3069.180 13-10-4BB-W 2KW
Stator v ariant 1
Phases
Starting current 19 A
Technical specification
Note: Picture might not correspond to the current configuration.
Power f actor
Motor ef f iciency
1/1 Load3/4 Load1/2 Load
1/1 Load3/4 Load1/2 Load
0.850.770.64
69.5 %72.2 %70.9 %
80 mmCurve ISO
P - Semi permanent, WetInstallation:
Configuration
Impeller material Grey cast iron
General
Discharge Flange Diameter 80 mm
Water, pure
Standard
Last updateCreated on
6/1/2017
Created byProject IDProject
P_2017_00555Received 29/06/2017
Head
Pump efficiency
Overall eff iciency
Pow er input P1
Shaft pow er P2
410 185mm410 185mm
47.4% Eff.
7.59 m
46.5 %
33.6 %
1.48 kW
9.24 l/s
2.05 kW
9.24 l/s
410 185mm410 185mm
7.59 m
46.5 %
33.6 %
1.48 kW
9.24 l/s
2.05 kW
9.24 l/s
410 185mm410 185mm
7.59 m
46.5 %
33.6 %
1.48 kW
9.24 l/s
2.05 kW
9.24 l/s
410 185mm (P2)410 185mm (P2)
7.59 m
46.5 %
33.6 %
1.48 kW
9.24 l/s
2.05 kW
9.24 l/s
410 185mm (P1)410 185mm (P1)
7.59 m
46.5 %
33.6 %
1.48 kW
9.24 l/s
2.05 kW
9.24 l/s
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
6.5
7.0
7.5
8.0
8.5
9.0
9.5
10.0
[m]
05
1015202530354045
[%]
0.4
0.8
1.2
1.6
2.0
2.4
[kW]
0 2 4 6 8 10 12 14 16 18 20 22 24 26 [l/s]
Motor #
50 Hz
Phases 3~
400 VNumber of poles 4
Rated power 2 kW
Starting currentRated current 4.9 A
Rated speed 1355 rpm
D3069.180 13-10-4BB-W 2KW
Stator variantNumber of blades 6
Power factor
DP 3069 LT 3~ 410
Suction Flange Diameter
Performance curve
Pump
Impeller diameter 185 mm
Motor
Rated voltage
19 A
Motor efficiency
1/1 Load3/4 Load1/2 Load
1/1 Load3/4 Load1/2 Load
Frequency1
0.85
69.5 %
0.770.64
72.2 %70.9 %
80 mm
Curve ISO
Flow Head ISO:1999 Grade
9 l/s 7.2 m No
Duty point Guarantee
Discharge Flange Diameter 80 mm
Water, pure
Last updateCreated on
6/1/2017
Created byProject IDProject
Head
410 185mm
47.4% Eff.
7.59 m
9.24 l/s0.0
0.4
0.8
1.2
1.6
2.0
2.4
2.8
3.2
3.6
4.0
4.4
4.8
5.2
5.6
6.0
6.4
6.8
7.2
7.6
8.0
8.4
8.8
9.2
9.6
10.0
[m]
0 2 4 6 8 10 12 14 16 18 20 22 24 26 [l/s]
1
DP 3069 LT 3~ 410Duty Analysis
Curve ISO
Indiv idual pump Total
1 9.24 l/s 7.59 m 1.48 kW 9.24 l/s 7.59 m 1.48 kW 46.5 % 0.0616 kWh/m³
Pumps running Specific /System Flow Head Shaft power Flow Head Shaft power Pump eff. energy NPSHre
Water, pure
Curve issue 4
Last updateCreated on
6/1/2017
Created byProject IDProject
DP 3069 LT 3~ 410Dimensional drawing
DP 3069 LT
DN80[3"]
*DIMENSION TO ENDS OF GUIDE BARS
REF.LINE
REF.LINE
(TO FURTHEST POINT)
MIN
LE
VEL
CL
OF
DIS
CH
Weight Pump Stand
kg 51 34
lbs 112 75
250[913
16]
200
[77 8]
100
[31
51
6]
72[213
16]
842[331
8]
149[57
8]
149
[57 8]
149
[57 8]
*264
[*1
03 8]
400
[153 4]
2" GUIDE BARS
352[137
8]
85[33
8]
239[97
16]
489
[191 4]
100
[31
51
6]
523
[209 16]
586[231
16]
63[27
16]
116[49
16]
14
[9 16]
23[78]
Z-Z
Z Z
Last updateCreated on
6/1/2017
Created byProject IDProject
Version 10
0% 0.00 GBP Energy
0% 0.00 GBP Investment costs
0% 0.00 GBP Installation & commissioning
0% 0.00 GBP Operating cost
0% 0.00 GBP Maintenance & repair
0% 0.00 GBP Downtime
0% 0.00 GBP Environmental
0% 0.00 GBP Decommissioning
0% 0.00 GBP Energy (1st year)
0% 0.00 GBP Investment costs (1st year)
0% 0.00 GBP Installation & commissioning (1st year)
0% 0.00 GBP Operating cost (1st year)
0% 0.00 GBP Maintenance & repair (1st year)
0% 0.00 GBP Downtime (1st year)
0% 0.00 GBP Environmental (1st year)
0% 0.00 GBP Decommissioning (1st year)
2 %
3 %
15
0.00
0.00
DP 3069 LT 3~ 410
5600
0.00 GBP
Inflation rate (rate of price increases)
Interest rate (for investment)
Total l ifetime
Annual operating time
Energy cost per kWh
Total costs
First year costs
Life cycle costs (LCC)
Disclaimer: The calculations and the results are based on user input values and general assumptions and provide only estimated costs for the input data. Xylem inc can therefore not guarantee that the estimated savings will actually occur.
GBP
GBP
Power input P1
Last updateCreated on
6/1/2017
Created byProject IDProject