Travel Distance = 105' - 0" 637 SF RETAIL 6377 SF MUSEUM 4944 SF RETAIL 13197 SF LOADING DOCK EXIT 16 576 SF RETAIL 3581 SF AE VAULTS 208 SF STORAGE 347 SF FIRE COMMAND 757 SF FIRE PUMP 8300 SF MAIN LOBBY EXIT 6 EXIT 7 EXIT 5 EXIT 8 EXIT 9 EXIT 10 EXIT 4 EXIT 12 EXIT 17 EXIT 11 EXIT 13 500 SF MECHANICAL 1542 SF ELECTRICAL STAIR 1 STAIR 6 STAIR 4 STAIR 3 STAIR 5 STAIR 2 123 SF BFP EXIT 1 EXIT 2 EXIT 3 597 SF RECYCLING 245 SF TRASH & COMPOST 180 SF BIKE ACCESS ELEV V ELEV U ELEV T ELEV H ELEV G ELEV S ELEV R ELEV F ELEV E ELEV Q ELEV D ELEV P ELEV O ELEV C ELEV B ELEV N ELEV A ELEV K ELEV J ELEV I EXIT 15 EXIT 18 ELEV L ELEV M DIAGONAL = 336' - 6" SEPARATION DISTANCE = 312' - 3" FIRE SERVICE ACCESS LOBBY 2055 SF GARAGE RAMP 1474 SF GARAGE RAMP 169 SF MECHANICAL 6345 SF RETAIL 569 SF TELECOM EXIT 7 LIFE SAFETY LEGEND ROOM NAME NAME AND AREA 1 HR FIRE BARRIER 1 HR FIRE/SMOKE BARRIER 2 HR FIRE BARRIER 2 HR FIRE/SMOKE BARRIER SMOKE PARTITION (NON RATED) NON RATED WALL HORIZONTAL EXIT WALL FIRE EXTINGUISHER CABINET FIRE HOSE CABINET STANDPIPE HOSE CNXN CABINET EMERGENCY KEY CABINET EXIT SYMBOL FEC FHC FIRE EXTINGUISHER FE SHC EKC EXIT SIGN - HATCH INDICATES EXIT TEXT & ARROW INDICATES DIRECTION XXX' - X" TRAVEL DISTANCE FROM THE MOST REMOTE POINT TO THE CLOSEST XXX' - X" TRAVEL DISTANCE WITHIN A SMOKE ZONE TO AN ADJACENT SMOKE ZONE 3 HR FIRE BARRIER 150 SF FIRE DEPARTMENT CONNECTION FDC BUS. OCCUPANCY ASSEMBLY EXIT CORRIDOR RETAIL STORAGE MECHANICAL 637 SF EXIT ACCESS CORRIDOR 457 SF EXIT ACCESS CORRIDOR 1809 SF EXIT ACCESS CORRIDOR SECTION 1023.1 REQUIRED: 2 HRS FOR TYPE IA CONSTRUCTION SEC. 708.4 PROVIDED: STAIRWELL W/2 HR FIRE BARRIER SHAFT EXIT ENCLOSURE AND 90 MINUTE LABELED DOOR IBC 707.3.1, 707.3.2, 1022.1 EXIT CAPACITY EXIT/STAIR NUMBER EXIT/STAIR WIDTH EXIT/STAIR CAPACITY STAIR 1 48" 48" / 0.2" = 240 Occpt. STAIR 1- DOOR DOOR WIDTH 42" OCCUPANT CAPACITY 40" / 0.15 = 266 SECTION 1023.1 REQUIRED: 2 HRS FOR TYPE IA CONSTRUCTION SEC. 708.4 PROVIDED: STAIRWELL W/2 HR FIRE BARRIER SHAFT EXIT ENCLOSURE AND 90 MINUTE LABELED DOOR IBC 707.3.1, 707.3.2, 1022.1 EXIT CAPACITY EXIT/STAIR NUMBER EXIT/STAIR WIDTH EXIT/STAIR CAPACITY STAIR 2 48" 48" / 0.2" = 240 Occpt. STAIR 2- DOOR DOOR WIDTH 42" OCCUPANT CAPACITY 40" / 0.15 = 266 SECTION 1023.1 REQUIRED: 2 HRS FOR TYPE IA CONSTRUCTION SEC. 708.4 PROVIDED: STAIRWELL W/2 HR FIRE BARRIER SHAFT EXIT ENCLOSURE AND 90 MINUTE LABELED DOOR IBC 707.3.1, 707.3.2, 1022.1 EXIT CAPACITY EXIT/STAIR NUMBER EXIT/STAIR WIDTH EXIT/STAIR CAPACITY STAIR 4 60" 60" / 0.2" = 300 Occpt. STAIR 4- DOOR DOOR WIDTH 48" OCCUPANT CAPACITY 46" / 0.15 = 306 SECTION 1023.1 REQUIRED: 2 HRS FOR TYPE IA CONSTRUCTION SEC. 708.4 PROVIDED: STAIRWELL W/2 HR FIRE BARRIER SHAFT EXIT ENCLOSURE AND 90 MINUTE LABELED DOOR IBC 707.3.1, 707.3.2, 1022.1 EXIT CAPACITY EXIT/STAIR NUMBER EXIT/STAIR WIDTH EXIT/STAIR CAPACITY STAIR 3 48" 48" / 0.2" = 240 Occpt. STAIR 3- DOOR DOOR WIDTH 36" OCCUPANT CAPACITY 34" / 0.15 = 226 SECTION 1023.1 REQUIRED: 2 HRS FOR TYPE IA CONSTRUCTION SEC. 708.4 PROVIDED: STAIRWELL W/2 HR FIRE BARRIER SHAFT EXIT ENCLOSURE AND 90 MINUTE LABELED DOOR IBC 707.3.1, 707.3.2, 1022.1 EXIT CAPACITY EXIT/STAIR NUMBER EXIT/STAIR WIDTH EXIT/STAIR CAPACITY STAIR 5 60" 60" / 0.2" = 300 Occpt. STAIR 5- DOOR DOOR WIDTH 48" OCCUPANT CAPACITY 46" / 0.15 = 306 SECTION 1023.1 REQUIRED: 2 HRS FOR TYPE IA CONSTRUCTION SEC. 708.4 PROVIDED: STAIRWELL W/2 HR FIRE BARRIER SHAFT EXIT ENCLOSURE AND 90 MINUTE LABELED DOOR IBC 707.3.1, 707.3.2, 1022.1 EXIT CAPACITY EXIT/STAIR NUMBER EXIT/STAIR WIDTH EXIT/STAIR CAPACITY STAIR 6 60" 60" / 0.2" = 300 Occpt. STAIR 6 - DOOR DOOR WIDTH 48" OCCUPANT CAPACITY 46" / 0.15 = 306 SECTION 1023.1 REQUIRED: 2 HRS FOR TYPE IA CONSTRUCTION SEC. 708.4 PROVIDED: STAIRWELL W/2 HR FIRE BARRIER SHAFT EXIT ENCLOSURE AND 90 MINUTE LABELED DOOR IBC 707.3.1, 707.3.2, 1022.1 EXIT CAPACITY EXIT/STAIR NUMBER EXIT/STAIR WIDTH EXIT/STAIR CAPACITY STAIR 4 60" 60" / 0.2" = 300 Occpt. STAIR 4 - EXIT ACCESS CORRIDOR DOOR WIDTH N/A CORRIDOR WIDTH 66" SECTION 1023.1 REQUIRED: 2 HRS FOR TYPE IA CONSTRUCTION SEC. 708.4 PROVIDED: STAIRWELL W/2 HR FIRE BARRIER SHAFT EXIT ENCLOSURE AND 90 MINUTE LABELED DOOR IBC 707.3.1, 707.3.2, 1022.1 EXIT CAPACITY EXIT/STAIR NUMBER EXIT/STAIR WIDTH EXIT/STAIR CAPACITY STAIR 3 48" 48" / 0.2" = 240 Occpt. STAIR 3- EXIT ACCESS CORRIDOR DOOR WIDTH N/A CORRIDOR WIDTH 60" SECTION 1023.1 REQUIRED: 2 HRS FOR TYPE IA CONSTRUCTION SEC. 708.4 PROVIDED: STAIRWELL W/2 HR FIRE BARRIER SHAFT EXIT ENCLOSURE AND 90 MINUTE LABELED DOOR IBC 707.3.1, 707.3.2, 1022.1 EXIT CAPACITY EXIT/STAIR NUMBER EXIT/STAIR WIDTH EXIT/STAIR CAPACITY STAIR 5 60" 60" / 0.2" = 300 Occpt. STAIR 4 - EXIT ACCESS CORRIDOR DOOR WIDTH N/A CORRIDOR WIDTH 66" SECTION 1023.1 REQUIRED: 2 HRS FOR TYPE IA CONSTRUCTION SEC. 708.4 PROVIDED: STAIRWELL W/2 HR FIRE BARRIER SHAFT EXIT ENCLOSURE AND 90 MINUTE LABELED DOOR IBC 707.3.1, 707.3.2, 1022.1 EXIT CAPACITY EXIT/STAIR NUMBER EXIT/STAIR WIDTH EXIT/STAIR CAPACITY STAIR 6 60" 60" / 0.2" = 300 Occpt. STAIR 6 - EXIT ACCESS CORRIDOR DOOR WIDTH N/A CORRIDOR WIDTH 60" SECTION 1023.1 REQUIRED: 2 HRS FOR TYPE IA CONSTRUCTION SEC. 708.4 PROVIDED: STAIRWELL W/2 HR FIRE BARRIER SHAFT EXIT ENCLOSURE AND 90 MINUTE LABELED DOOR IBC 707.3.1, 707.3.2, 1022.1 EXIT CAPACITY EXIT/STAIR NUMBER EXIT/STAIR WIDTH EXIT/STAIR CAPACITY STAIR 1 48" 48" / 0.2" = 240 Occpt. STAIR 1- EXIT ACCESS CORRIDOR DOOR WIDTH N/A CORRIDOR WIDTH 60" SECTION 1023.1 REQUIRED: 2 HRS FOR TYPE IA CONSTRUCTION SEC. 708.4 PROVIDED: STAIRWELL W/2 HR FIRE BARRIER SHAFT EXIT ENCLOSURE AND 90 MINUTE LABELED DOOR IBC 707.3.1, 707.3.2, 1022.1 EXIT CAPACITY EXIT/STAIR NUMBER EXIT/STAIR WIDTH EXIT/STAIR CAPACITY STAIR 2 48" 48" / 0.2" = 240 Occpt. REVISION HKS PROJECT NUMBER DATE SHEET TITLE SHEET NO. PLOT DATE: ISSUE © 2018 HKS, INC. TEMPLATE VERSION: THE REPUBLIC LINCOLN PROPERTY COMPANY DALLAS, TX 75201 OWNER 2000 MCKINNEY AVENUE, SUITE 1000 MBC CONSULTANTS TERRELL, TX 75160 OWNER REPRESENTATIVE 113 W. MOORE AVE. DESIGN ARCHITECT DUDA|PAINE ARCHITECTS, PA DURHAM, NC 27701 333 LIGGETT STREET ARCHITECT OF RECORD HKS INC. DALLAS, TX 75201 - 4240 350 N SAINT PAUL ST, SUITE 100 STRUCTURAL ENGINEER BROCKETTE DAVIS DRAKE, INC. DALLAS, TX 75204 4144 NORTH CENTRAL EXPRESSWAY, SUITE 1100 MEP ENGINEER BLUM CONSULTING ENGINEERS, INC. DALLAS, TX 75231 8144 WALNUT HILL LANE, SUITE 200 CIVIL ENGINEER BIG RED DOG ENGINEERING & CONSULTING AUSTIN, TX 78702 2021 EAST 5TH STREET, SUITE 200 PARKING CONSULTANT PARC, INC. DRIPPING SPRINGS, TX 78620 1678 BEAUCHAMP ROAD LANDSCAPE ARCHITECT TBG PARTNERS AUSTIN, TX 78701 1705 GUADALUPE STREET, SUITE 500 AUSTIN, TEXAS ELEVATOR CONSULTANT LERCH BATES DALLAS, TX 75201 2001 BRYAN STREET, SUITE 1930 LIGHTING DESIGNER CBBLD NEW YORK, NY 10016 116 EAST 27TH STREET, 4TH FLOOR 11/2/2018 3:54:33 PM ALS.01 LIFE SAFETY PLANS - LEVEL 01 GROUND & 1.5 TRANSFERS 02 NOVEMBER 2018 21440.000 BUILDING PERMIT 3.0.0.20170623 1/16" = 1'-0" 01 LIFE SAFETY PLAN - LEVEL 01 GROUND LIFE SAFETY OCCUPANT SUMMARY - LEVEL 01 GROUND PRIMARY USE AREA SF OCCUPANT LOAD FACTOR PER PERSON OCCUPANT LOAD ASSEMBLY (30) 6377 SF 30 SF 213 BUSINESS 8300 SF 100 SF 84 MECHANICAL 3581 SF 300 SF 12 MECHANICAL 347 SF 300 SF 2 MECHANICAL 757 SF 300 SF 3 MECHANICAL 500 SF 300 SF 2 MECHANICAL 1542 SF 300 SF 6 MECHANICAL 123 SF 300 SF 1 MECHANICAL 169 SF 300 SF 1 MECHANICAL 569 SF 300 SF 2 MERCANTILE 637 SF 60 SF 11 MERCANTILE 4944 SF 60 SF 83 MERCANTILE 576 SF 60 SF 10 MERCANTILE 6345 SF 60 SF 106 PARKING 2055 SF 200 SF 11 PARKING 1474 SF 200 SF 8 STORAGE 13197 SF 300 SF 44 STORAGE 208 SF 300 SF 1 STORAGE 597 SF 300 SF 2 STORAGE 245 SF 300 SF 1 STORAGE 180 SF 300 SF 1 GRAND TOTAL 52725 SF 604 1/16" = 1'-0" 02 LIFE SAFETY PLAN - LEVEL 1.5 TRANSFER N TRUE NORTH N PROJECT NORTH EXIT SUMMARY - DOORS - LEVEL 01 GROUND EXIT TYPE EXIT NUMBER CODE EXIT FACTOR WIDTH PROVIDED IN INCHES CAPACITY IN PERSONS EXIT 1 0.15 34" 227 EXIT 2 0.15 34" 227 EXIT 3 0.15 34" 227 EXIT 4 0.15 70" 467 EXIT 5 0.15 70" 467 EXIT 6 0.15 40" 267 EXIT 7 0.15 40" 267 EXIT 7 0.15 34" 227 EXIT 8 0.15 46" 307 EXIT 9 0.15 70" 467 EXIT 10 0.15 70" 467 EXIT 11 0.15 70" 467 EXIT 12 0.15 70" 467 EXIT 13 0.15 46" 307 EXIT 15 0.15 70" 467 EXIT 16 0.15 40" 267 EXIT 17 0.15 70" 467 EXIT 18 0.15 70" 467 GRAND TOTAL: 18 6526 VERTICAL SHAFT EXIT ENCLOSURE PRESSURIZED VERTICAL SHAFT EXIT ENCLOSURE PRESSURIZED ELEVATOR HOISTWAY / FIRE SERVICE ACCESS WALLS: 2 HOUR REQUIRED, SEC 708.4 FIRE SERVICE ACCESS ELEVATOR LOBBY, SECTION 3007.4 STANDPIPE/ HOSE STATIONS, SECTION 905.4 VERTICAL SHAFT EXIT ENCLOSURE PRESSURIZED VERTICAL SHAFT EXIT ENCLOSURE PRESSURIZED ELEVATOR HOISTWAY SECTION 708.4 WALL: 2 HOUR REQUIRED SECTION 3008 OCCUPANT EVACUATION ELEVATORS ELEVATOR HOISTWAY SECTION 708.4 WALL: 2 HOUR REQUIRED SECTION 3008 OCCUPANT EVACUATION ELEVATORS VERTICAL SHAFT EXIT ENCLOSURE PRESSURIZED VERTICAL SHAFT EXIT ENCLOSURE PRESSURIZED VERTICAL SHAFT EXIT ENCLOSURE PRESSURIZED VERTICAL SHAFT EXIT ENCLOSURE PRESSURIZED VERTICAL SHAFT EXIT ENCLOSURE PRESSURIZED VERTICAL SHAFT EXIT ENCLOSURE PRESSURIZED VERTICAL SHAFT EXIT ENCLOSURE PRESSURIZED VERTICAL SHAFT EXIT ENCLOSURE PRESSURIZED ELEVATOR HOISTWAY SECTION 708.4 WALL: 2 HOUR REQUIRED SECTION 3008 OCCUPANT EVACUATION ELEVATORS ELEVATOR HOISTWAY SECTION 708.4 WALL: 2 HOUR REQUIRED SECTION 3008 OCCUPANT EVACUATION ELEVATORS LIFE SAFETY OCCUPANT SUMMARY - LEVEL 1.5 STAIRS TRANSFER PRIMARY USE AREA SF OCCUPANT LOAD FACTOR PER PERSON OCCUPANT LOAD N/A N/A N/A N/A NO. DESCRIPTION DATE 1/ /2018 0 20 1