MindTuner X1-10

• Up to 8 channels EEG• 1 ECG channel• 1 EMG channel• 1 GSR channel• 1 TEMP channel

Total 10 channels

www.mindtuner.net

The 10 channel solution

Page 3: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 3

MindTuner X1-10 Specifications

• 10 Channel EEG-Biofeedback6-8 EEG

1 ECG, EMG, GSR, TEMP

• Dual 24-bits signal conversion

• Variable sampling rateUp to 13.000 samples/sec. total HW capacity

• USB connection

• System inter-connectability

• Software compatibilityMindTuner software

Bio-Explorer

Neuroguide

Labview

More to follow soon

Page 4: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 4

EEG-Biofeedback features

• 8 Channel EEG training

• Combined bio-feedbackEEG-ECG-EMG-GSR-TEMP

• Wide variety of protocolsamplitude

standard deviation

coherence

binaural beats

ratio

similarity

synchrony

comodulation

etc.

• Mini QEEG

• Programmed for flexibility

Page 5: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 5

MindTuner Software

MindTuner software

Page 6: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 6

Sequentiële – Bipolaire montage

Page 7: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 7

Multiple Channel view

Page 8: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 8

Session Summary

Page 9: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 9

Spectrum analyze

Page 10: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 10

Ratio Training

Page 11: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 11

Standard Deviation training

Page 12: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 12

Band Coherence

Page 13: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 13

FeedbackMovies/games

Feedback options

Page 14: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 14

movies

Page 15: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 15

Walker / Pacman variant

Page 16: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 16

Mini QEEG

Mini QEEG

Page 17: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 17

Mini QEEG Assessment

Page 18: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 18

Evaluation

Page 19: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 19

Assessment maps

Page 20: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 20

ECG, EMG, GSR, Temperature

ECG, EMG, GSR and temperature

Page 21: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 21

ECG

Page 22: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 22

EMG, Galvanic skin response and Temperature

Page 23: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 23

EXTRA’S

Extra’s

Page 24: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 24

Connection test

Page 25: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 25

Location

Page 26: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 26

Session Comments

Page 27: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 27

Artifact

Page 28: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 28

Define Bands

Page 29: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 29

Midi Setings

Page 30: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 30

Binaural Sounds

Page 31: ©  MindTuner X1-10 Neurotherapie Centrum Hilversum Pole to Pole Communications BV .

© WWW.MINDTUNER.NET Page: 31

Input channels 10 EEG 6(+2) – channel ECG 1 – channel EMG 1 – channel Galvanic Skin Response channel 1 – channel Temperature channel 1 – channel EEG band pass 0,16 to 40 Hz ECG band pass 0,16 to 40 Hz EMG band pass 0,16 to 1000 Hz GSR range  0-200 µSiemens TEMP range 0-70 C Input Impedance 10 G Ohm Driven Right Leg frequency 50 / 60 Hz Notch filter 50 / 60 Hz 24 bits ADCs 2 Average power consumption 0,75 W Common Mode Rejection 116 dB Sampling frequency 1,024 samples / sec / channel   max 13,000 samples / sec / MindTuner unit PC connection USB 1.1 / 2.0 compatible Power source 5V USB Optical isolation 8000 V Amplifier failure protection < 50 µA Electrode impedance test 250 Ohm to 1 M Ohm Dimensions (l * w * h) 180 * 206 * 64 mm

MindTuner X1-10 - technical specifications