5.2 MW Solar Mobile Power Unit Neutral Grounding Resistor Lube oil cooler Leveling jacks & pads Access stairs & platforms Exhaust Silencer Ventilation air intake Gas & Liquid Fuel Connections Air inlet & silencer 13.8 to 480 vac Aux. Power Transformer Ventilation air exhaust Power Control Room & Trailer -13.8 KV switchgear -CO2 fire system -480 VAC MCCC for turbine accessories -120VDC battery systems -Allen Bradley TT4000 Monitor/control
36
Embed
gabrielandassociates.comgabrielandassociates.com/support-files/SolarT60MPU... · Translate this page%PDF-1.6 %âãÏÓ 172 0 obj endobj xref 172 15 0000000016 00000 n 0000001246
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
5.2 MW Solar Mobile Power Unit
Neutral Grounding Resistor
Lube oil cooler
Leveling jacks & pads
Access stairs & platforms
Exhaust Silencer
Ventilation air intake
Gas & Liquid Fuel Connections
Air inlet & silencer
13.8 to 480 vac Aux. Power Transformer
Ventilationair exhaust
Power Control Room &Trailer-13.8 KV switchgear-CO2 fire system-480 VAC MCCC for turbineaccessories
Standard Solar Taurus 60 Power Gen. PackageRapid Setup & CommissioningEase of transport…Land, Sea, & AirTotally self contained, Needs only…
o Gas and/or Liquid Fuel o 13.8kV load connectiono Black Start Requires 480VAC
Mobile Turbine Design Goals
Standard Solar Taurus 60 Power Gen. Package
Parts ServiceOverhaulsUpgrades Retrofits
Solar T60 – Engine
Simple Cycle Single shaft axial flow engine Close Coupled to separate Gear Box Twelve-stage axial flow compressor Variable geometry control on inlet guide vanes and first three rows of statorsAnnular combustor with 12 fuel injectorsThree-stage turbine assembly
Standard Solar Taurus 60 Power Gen. Package
Solar T60 – Gear Box
Coupled directly to the turbine engineSpeed Reduciton from 13,800RPM to 1800 RPM
Solar T60 – Generator & Voltage Regulation
Ideal or AlstomSleeve Bearings with pressure fed sumpsSix-lead WYE connectionForm wound stator windingsPermanent magnet pilot exciter12,470 – 13,800 Volt, 3 phase, 60 Hz. 11kV, 3 phase, 50 Hz. Insulation class F with Voltage Regulator CharacteristicsSolid state, Single-phase sensing0.5% steady state voltage regulationReactive load sharing to within 5% nameplate ratingCrosscurrent compensation capability
Solar T60 – Dual Fuel System
Designed to operate on Natural Gas or Distillate Liquid Fuels
NATURAL GASo maximum flow demand rate of 1200 scfmo 250 psig minimum and 300 psig maximum
Distillate Liquid Fuelso maximum flow demand rate of 8.0 gpm. o 20ft. Suction minimum to 25 psig maximum
Solar T60 – Starter, Lube system
Direct drive AC motor with VFD motor controllerLube system provides oil to the Taurus 60 gas turbine engine, gear box and generator.
o Engine driven lube oil pumpo Pre/Post Lube AC Motor Driven Pumpo Pre/Post Lube DC Motor Drive Pumpo Lube Oil Sump (integral part of turbine skid) with
space heater, level controls, and thermostatic control valve.
o Horizontal core lube oil cooler mtd. on Power Control Room
Solar T60 – Auxiliary Systems
On Crank and On Line Water WashWEATHERPROOF ACOUSTIC ENCLOSURE
o Ventilation Silencers and Fans, o Lightso Fire Detection and Gas Monitoring System o High Temperature Detection and Alarmo CO2 Fire Suppression System.
High Efficiency Combustion Air Barrier Filter and Silencer Trailer mounted exhaust silencer