Acid Dilution 6 7 With squeeze chamber 2 until capsule breaks. , thumb and forefinger Gently shake test unit for 2-3 seconds. Wait 5 minutes. Disposal The test kit is now safe to dispose of in the trash. Acid Dilution 8 9 With squeeze chamber 3 until capsule breaks. , thumb and forefinger Gently shake test unit for 2-3 seconds. Denta I World Leader in Forensic Products All results are presumptive. If necessary, further confirmatory testing by a competent drug testing lab may provide additional identification and quantification using gas chromatography/mass spectrometry analysis. 99% accurate presumptive field screening when used correctly. Manufactured by IDenta Corp. www.identa-corp.com • +972-2-5872220 • Patented Technology Made in Israel The test window will warm up. This is normal. The test window will warm up. This is normal. As a precaution, gloves and eye protection should be worn when handling drug substances and using test units. Do not puncture any part of unit. Do not remove probe once locked into unit. In the unlikely event of a spill, rinse affected area thoroughly with water. Keep out of reach of children. Gently shake test unit for 2-3 seconds. 4 With , squeeze chamber 1 until capsule breaks. thumb and forefinger 5 Identification If no color develops, MDMA/Amphetamine precursors are not present. Proceed to Acid Dilution (steps 6-9), regardless of whether or not a color appeared. The appearance of a red-brown color indicates the presence of 3,4- Methyleneedioxyphenyl-2 propanone (PMK, MDP2P). The appearance of an intense yellow color indicates the presence of Piperonal. If the substance is a liquid, the appearance of an orange color indicates the presence of Safrole. * Color may turn to violet after 10-15 minutes. If the substance is a solid, the appearance of an orange color indicates the presence of 1-phenyl-2-propaneone (BMK). Results Powder 2 1 Test Preparation Sample suspected substance. To u c h adhesive Smart-Tip™ to sample. Liquid Remove the Smart-Tip™ probe from test unit. Place the absorbent paper of Smart-Tip™ probe into liquid. Make sure paper is wet. Lock Smart- Tip™ probe into test unit. Press firmly. Flex Pins Lock Smart- Tip™ probe into test unit. Press firmly. 3 Test Preparation Flex Pins Do not continue unless probe is locked below the Flex Pins and cannot be removed from the test unit. A click sound will indicate the probe is locked. 10-13 READ BEFORE USE IDenta MDMA - Amphetamine Precursors Substance Procedure Card for IDT 0270-10 DRUG PRECURSORS TEST KIT