Page 1: High Power RF Systems (352 MHZ - 12 GHz)  High Efficiency Power Sources  High Voltage Systems  High Gradient Accelerating Structures.

Olivier Brunner, on behalf of RF/MK.

RF/MK: 2014 in a nutshell

Page 2: High Power RF Systems (352 MHZ - 12 GHz)  High Efficiency Power Sources  High Voltage Systems  High Gradient Accelerating Structures.

What we do…

High Power RF Systems (352 MHZ - 12 GHz)

High Efficiency Power Sources

High Voltage Systems

High Gradient Accelerating Structures

Page 3: High Power RF Systems (352 MHZ - 12 GHz)  High Efficiency Power Sources  High Voltage Systems  High Gradient Accelerating Structures.

Who we are… 36 persons 9 status

• FELL• DOCT• PJAS• STAFF• VISC• COAS• ADMI• DOCT• TRN

14 nations• Scotland• Italy• Russia• Holland• Spain• Germany• Swizerland• France• Belgium• Japan• Finland• Hungary• Greece• Pakistan

a big THANK YOU to everyone !!!

Page 4: High Power RF Systems (352 MHZ - 12 GHz)  High Efficiency Power Sources  High Voltage Systems  High Gradient Accelerating Structures.

The LHC RF System

Page 5: High Power RF Systems (352 MHZ - 12 GHz)  High Efficiency Power Sources  High Voltage Systems  High Gradient Accelerating Structures.

LS1 activities: Upgrade, Repair, Commissioning

• HV connectors repair campaign (>100)• New crowbar systems• Replacement of obsolete equipment (e.g. Tetrode):R&D in

progress• New arc detectors (License agreement signed with an external company)

• Control system upgrade• Reliability is a key issue here

Page 6: High Power RF Systems (352 MHZ - 12 GHz)  High Efficiency Power Sources  High Voltage Systems  High Gradient Accelerating Structures.

Energetic & sporting activities

Diet plans: http://www.eatingwell.com/nutrition_health/weight_loss

Page 7: High Power RF Systems (352 MHZ - 12 GHz)  High Efficiency Power Sources  High Voltage Systems  High Gradient Accelerating Structures.

Installation: equipment, waveguides, water cooling, local cabling LEP equipment: 20 – 30 year old! , CW klystrons now being pulsed 6 HPRF units fully commissioned / on schedule Reliability is a key issue here

Linac 4 – HPRF system installation and commissioning

Page 8: High Power RF Systems (352 MHZ - 12 GHz)  High Efficiency Power Sources  High Voltage Systems  High Gradient Accelerating Structures.

Linac 4 – HPRF development

3 post phase tuner• 352MHz, 1.5 MW peak• WR 2300, L = 1500 mm, r1=70mm, r2 = 40mm • VSWR ≈ 1.2 [depth 0 -> 100 mm]• S11 ≤ -30 dB [depth 0 -> 90 mm]• Range: ≈ max 60˚

Page 9: High Power RF Systems (352 MHZ - 12 GHz)  High Efficiency Power Sources  High Voltage Systems  High Gradient Accelerating Structures.

CTF3 Facility

CTF3 maintenance, upgrade & operation :• 11 S Band and 1 L Band power sources• Complexe waveguide systems• HV system upgrade (thyratron replacement by solid state devices)

Plateform for experiments

Page 10: High Power RF Systems (352 MHZ - 12 GHz)  High Efficiency Power Sources  High Voltage Systems  High Gradient Accelerating Structures.

The test Beam Line (TBL): a small scale version of a CLIC decelerator

Experimental demonstration of the:• deceleration process • beam dymanic issues• power production in PETS• power transfer to accelerating structures• main beam acceleration => high gradients

Page 11: High Power RF Systems (352 MHZ - 12 GHz)  High Efficiency Power Sources  High Voltage Systems  High Gradient Accelerating Structures.

Drive Beam front-end developments

Gun SHB 1-2-3 PB Buncher Acc. Structures

500 MHzModulator-klystrons, 1 GHz,

20 MW

~ 140 keV ~ 12 MeV

Diagnostics

Beam dynamics studies completed Gun and buncher prototypes being

constructed

Page 12: High Power RF Systems (352 MHZ - 12 GHz)  High Efficiency Power Sources  High Voltage Systems  High Gradient Accelerating Structures.

Zone with welding defect

Thales Electron Devices:10 beam multi beam klystrons77 % efficiency calculated

Toshiba:6 beam multi beam klystrons75 % efficiency calculated

Delivery and test in 2016

Drive Beam front end RF power

• Development of a very high efficiency L-band multi-beam klystron with industry

• 1 GHz, 20 MW, 150 ms, 50 Hz, > 70% efficiency

Page 13: High Power RF Systems (352 MHZ - 12 GHz)  High Efficiency Power Sources  High Voltage Systems  High Gradient Accelerating Structures.

First CLIC prototype module installed in CLEX

TD26R05CC

Page 14: High Power RF Systems (352 MHZ - 12 GHz)  High Efficiency Power Sources  High Voltage Systems  High Gradient Accelerating Structures.

Zone with welding defectOur range: 100 MV/m CLIC 50 MV/m low-β proton therapy linacs

High Gradient Activities

State-of-the-acceleration: Normal conducting:

≈30 MV/m SwissFEL Superconducting:

31.5 MV/m ILC LHC < 8MV/m Not only for CLIC !

Page 15: High Power RF Systems (352 MHZ - 12 GHz)  High Efficiency Power Sources  High Voltage Systems  High Gradient Accelerating Structures.

Applications of High Gradient Linac Technology

Page 16: High Power RF Systems (352 MHZ - 12 GHz)  High Efficiency Power Sources  High Voltage Systems  High Gradient Accelerating Structures.

High Gradient Structures

222

mm

Production of RF accelerating structures is very challenging

It comprises subsequent steps and quality analysis control

Page 17: High Power RF Systems (352 MHZ - 12 GHz)  High Efficiency Power Sources  High Voltage Systems  High Gradient Accelerating Structures.

High Gradient Testing – Xbox1

TD26R05CC

Full-fledged CLIC accelerating structure TD26R05CC build by CERN is successfully processed in XBOX1 up to 107 MW/m at 250 ns pulses

Page 18: High Power RF Systems (352 MHZ - 12 GHz)  High Efficiency Power Sources  High Voltage Systems  High Gradient Accelerating Structures.

High Gradient Testing – Xbox2

Page 19: High Power RF Systems (352 MHZ - 12 GHz)  High Efficiency Power Sources  High Voltage Systems  High Gradient Accelerating Structures.

High Gradient Testing – Xboxe3

Presented by Igor

Page 20: High Power RF Systems (352 MHZ - 12 GHz)  High Efficiency Power Sources  High Voltage Systems  High Gradient Accelerating Structures.

MERRY CHRISTMASS AND HAPPY NEW YEAR