Top Banner
WHC-SA-1976-FP ' Hanford Site Tank 241-SY-101, Damaged Equipment Removal Preparedforthe U.S. Department of Energy Office of Environmental Restorationand Waste Management _ WestinKhouse Hanford Company Richland, Washington HanfordOperations andEngineering Contractor forthe U.S.Department ofEnergyunderContract DE-ACO6-87RL10930 4 Copyright License By acceptanceofthisirtide, the publish_ and/orrecipientacknowledges the U.S. Government's rightto retaina nonexctusive,royalty-free licensein andto any(;:opy_ight coveringthis paper. Approvedfor PublicRelease "_'Fi_IBUTIOi'_ OF THIS I:)OCUMENT IS UNLIMITED
17

' Hanford Site Tank 241-SY-101, Damaged Equipment Removal

Jan 01, 2017

Download

Documents

duongkhanh
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: ' Hanford Site Tank 241-SY-101, Damaged Equipment Removal

WHC-SA-1976-FP

' Hanford SiteTank 241-SY-101,Damaged EquipmentRemoval

Preparedforthe U.S.Departmentof EnergyOfficeof EnvironmentalRestorationandWasteManagement

_ WestinKhouseHanfordCompanyRichland, WashingtonHanfordOperationsandEngineeringContractorfortheU.S.DepartmentofEnergyunderContractDE-ACO6-87RL10930

4 Copyright License Byacceptanceofthisirtide, the publish_ and/orrecipientacknowledgesthe U.S. Government's righttoretaina nonexctusive,royalty-freelicensein andto any(;:opy_ightcoveringthispaper.

Approvedfor PublicRelease

"_'Fi_IBUTIOi'_ OF THIS I:)OCUMENT IS UNLIMITED

Page 2: ' Hanford Site Tank 241-SY-101, Damaged Equipment Removal

C_.._._ i J(oc>- -,__5WHC-SA-1976-FP

• Hanford S:_qTank 241-SY-101Damaged u,pment Removai

P.A. TitzlerD. E. LegareH. G. Barrus

DatePublishedNovember 1993

To be presentedatANS1993WinterMeetingSanFrancisco,CalifomiaNovember14-19,1993

Prepared for the U.S. Department of EnergyOffice of Environmental Restoration andWaste Management

(_ Westini[houseP.O.Box1970HanfordCompanyRichland,Washington99352

Hanford Operations and Engineering Contractor for theU.S. Department of Energy under Contract DE-AC06-87RL10930

• Copyright License By,..accept,,anceofthisarticle,thepubSs.herandiorrecipientacknowledgestheU.S.Government'srighttoretaina nonexclusiva,royany-treedcenseinandtoanycopyrightcoveringthispaper.

Approved for Public Release MASTEROI_TI_IB"UTIONOF THIS DOCUMENT IS UNLIMITED

Page 3: ' Hanford Site Tank 241-SY-101, Damaged Equipment Removal

LEGALDISCLAIMER

Thisreportwaspreparedasan accountof worksponsoredbyan agencyof theUnitedStatesGovernment.NeithertheUnitedStatesGovernmentnoranyagencythereof,noranyoftheiremployees,noranyof theircontractors,subcontractorsor theiremployees,makesanywarranty,expressor implied,or assumesanylegalliabilityorresponsibilityfortheaccuracy,completeness,orany thirdparty'suseor the resultt_of suchuseof anyinformation,apparatus,product,orprocessdisclosed,or representsthatits usewouldnotinfringeprivatelyownedrights. Referencehereinto anyspecificcommercialproduct,process,orservicebytradename,trademark,manufacturer,orotherwise,doesnotnecessarilyconstituteor implyitsendorsement,recommendation,orfavoringby theUnitedStatesGovernmentoranyagencythereofor itscontractorsorsubcontractors.Theviewsandopinionsof authorsexpressedhereindo notnecessarilystateor reflectthoseof the UnitedStatesGovernmentoranyagencythereof.

Thisreporthas beenreproducedfromthebestavailablecopy.

Printed in the UnitedStatesofAmerica

DtSCLM.2,CHP(t-91)

Page 4: ' Hanford Site Tank 241-SY-101, Damaged Equipment Removal

WHC-SA-Ig76-FP

HANFORDSITE TANK241-SY-101, DAMAGEDEQUIPMENTREMOVAL

• P.A. TitzlerD. E. LegareH. G. Barrus

ABSTRACT

Hanford Site Tank 241-SY-I01has a historyof generatinghydrogen-

nitrous oxide gases. The gases are generatedand trappedin the non-

convectivewaste layernear the bottom of the 23-m- (75-it-)diameter

undergroundtank. Approximatelyevery three months the pressure in the tank

is relieved as the trappedgases are releasedthroughor around the surface

crust into the tank dome. This process moves large amountsof liquidwaste

and crust material around in the tank. The moving waste displaced air lances

and thermocoupleassemblies(2-in. schedule-40pipe) installedin four tank

risers and permanentlybent them to a maximum angle of 40 degrees. The bends

were so severe that assembliescould not be removedfrom the tank using the

originallydesigned hardware. Just after the tank releasesthe trappedgas, a

20-to-30-daywork "window"opens.

An engineeredsystem was developedand successfullyused to remove the

damaged tank hardware throughthe 10-cm- (4-in.-)diameter risers in which

they were originally installed. Some phases of the removaloperationrequired

that equipmentbe designed for remoteoperationand total containmentbecause

• of high radiationfields (up to 8 Rad/h). The equipmenthad to be

electricallybonded becauseof the potentialof hydrogen ventingduring the

removalprocess. The equipmentwas designed to extract the assemblies slowly

so that sparks or heat would not be generatedas an ignitionsource for the

Page 5: ' Hanford Site Tank 241-SY-101, Damaged Equipment Removal

WHC-SA-1976-FP

hydrogen. Sparks could occur if spray nozzleswere shearedoff the assemblies

too quickly. Also, the removalprocess involvedmetal-to-metalcontactwhen

" the assemblieswere straightenedby exerting largepressure loads against the

bottom of the risers.

e

Page 6: ' Hanford Site Tank 241-SY-101, Damaged Equipment Removal

WHC-SA-1976-FP

TANKDESCRIPTION

Tank 241-SY-I01containsa bottom layer of sludge 5.1 m (16.7 ft) thickwith a 4.1-m- (13.3-ft-)layer of liquid on top of the sludge,topped by a

" crust with an estimatedheight of 1.1 m (3.5 ft). The tank is of double-wallconstruction,consistingof a 23-m- (75-ft-)diameter steel primary inner tankwithin a 24.4-m- (80-ft-)diameter steel secondaryouter tank. The overall

" maximum height within the primary tank is 14.3m (47 ft). The tank contains10 risers extendingapproximately2.7 m (9 ft) from the tank dome to gradelevel. The risers have the followingdiameters: 10 cm (4 in.), 15.2 cm(6 in.), 30.5 cm (12 in.), and 106.7 cm (42 in.). Three air lances and onethermocoupletree were installedin four of the 10-cm (4-in.)risers, one ineach riser.

AIR LANCEANDTHERMOCOUPLECONDITION

The air lances and thermocoupletree were built from 2-in. schedule-40pipe approximately10 years ago. Pipe lengthswere welded togetherapproximatelyevery 6.1 m (20 ft). The air lance welds were 100 percentpenetrationwelds; the thermocouplewelds were less than 100 percentpenetration. The air lances also had spray nozzles installedat 1.5-m (5-ft)intervalson the sectioncontactingthe waste. All four assemblieswere bentjust below the riser dome interfaceby as much as 40 degrees (FigureI). Acoating of dried waste covered a sectionof the pipe includinglarge-diameterwaste-cakeballs that adheredto the pipes just above the waste (Figure2).

REMOVALEQUIPMENT

The air lance and thermocouple tree removal hardware included a modified37-ton commercialwell-casingpuller (Figure3), a 20.2-m- (66-ft-) longreceiverand receiver stand (Figure4), containmenttubes and boots, rigging,assemblycleaning equipment,load measuringequipment,a shieldedglove box,and specialretrievalequipment. Hardwarewas designed to be installedon thetop of the tank dome risers for the removal process. The equipment kept theremoval reaction force (compressionloads) appliedto the riser only. Thismethod preventeddamaging the riser-to-tank-dome-interfaceattachmentweld,which is consideredpart of the tank containment. Also, equipmentwasdesigned to remove large deposits of hard waste material that was attached toeach of the bent assemblies. The hot water spray system removedwastematerial before and during the pullingoperation. All hardware waselectricallybonded to the riser during the removalprocess because of theslight possibilityof hydrogenventingduring the removal operation.

The assemblieswere straightenedduring the removaloperationusing thebottom of the riser as a pivot point. The carbon steel assemblieswere taken

° slightlybeyond the yield point to straightenthem enough to be pulled throughthe riser. The rebendingoperationcaused very little damage to the bottom ofthe riser.

Modificationsto the well-casingpullers used on the radioactivestoragetank includedchanging the top and bottom plates to provide enough room forthe containmentequipmentand to allow the slip bowl on the top plate to

Page 7: ' Hanford Site Tank 241-SY-101, Damaged Equipment Removal

WHC-SA-1976-FP

float. Movement of the slip bowl was needed to relieve some of the sideloadingcaused by the bent pipe as it passed throughthe puller assembly. Thecontainmentused on the equipmentcan be seen in Figure 3. The lowercontainmentconsistedof sealed telescopingclear plastictubes between the

" top and bottom plate. The upper containmentwas a flexible plastictube toallow for misalignmentbetweenthe puller and receiver. Once the shieldedglove box was placed over the pullingequipment,all removaloperationswere

" completedremotely. Glove box ports were availablefor nonstandardproceduresif problems were encountered.

SPECIALRETRIEVALTOOLS

Special retrievaltools consistedof commercialpipe internalmandrelsthat were modified so they could be maneuveredaround large angles to retrievebroken pipes. The thermocoupletree broke at two weld joints because of lessthan 100 percent penetration. When the pipe broke, angles estimatedat up toapproximately40 degrees had to be accommodatedto latch the retrievaltools•The first break occurred insidethe lower sectionof the riser. The brokenpipe was jammed againstthe riser wall at an approximately20-degreeangle.Access to the broken pipe was limitedthrough a !O-cm- (4-in.-)diameterriser. A commercialmandrelused in the well-drillingindustrywas modified,then attachedto a speciallydesignedswivel joint and mounted on the end of ahigh-strengthextensionrod (Figure5). This apparatuswas used to grapplethe broken pipe end. The second break was at a sectionof pipe located justbelow the bottom of the riser. Two sectionsof pipe were being held togetherby a small sectionof the metal wall. This break could be seen using an in-tank camera. The grapple for this retrievalconsistedof a split blockattachedto a 16-mm (5/8-in.)cable. The split block concept had been used toretrievepipes sections in wells and it was recommendedby an offsiteconsultant. This conceptwas modifiedby adding lead-incomponentsandspecialwire ties to assist in positioningthe split blocks. Thesemodificationsallowedthe split blocks to be installedthrough the internaldiameter of the top sectionof the broken pipe and go around the 40-degreeangle at the break then into the internaldiameter of the lower sectionofpipe. The grappleand 5.2-m- (17-ft-)long cable was guided into positionusing a taperedguide designed to maneuver a 40-degreebend without catchingon the broken ends of the pipe. Fiber optic cameraswere used before eachbroken-piperetrievaloperationto determineif obstructionswere presentinside the thermocoupleassembly.

TEST PROGRAM

A preliminarytest program was completedin parallel to designingtheremoval equipment. As the individualtest resultsbecame available,they wereused to improvethe design. The preliminarytests were used to determinethe

' required removal loads and the feasibilityof using commerciallyavailablecasing pullingequipment. The latter part of the preliminarytest phase alsoverified fit-up and operationof removalequipmentand containmentcomponents.

• The removal loads were determinedby forcinga simulatedbent assembly througha full-scaleriser mockup. The removal-loadtesting also included shearingoff nozzles (I/B-in.pipe plugs), simulatingthose installedon the airlances. In addition,methods for removingthe material caked on the lances

Page 8: ' Hanford Site Tank 241-SY-101, Damaged Equipment Removal

WHC-SA-1976-FP

were tested. The final checkoutand qualificationtestingof the removalequipmentwas completedbefore releasingthe equipmentto Tank Farm Operationsfor field use.

The resultsof removal-loadtests at the mockup facility indicateda forceof between6,000 and 12,000 pounds would be requiredto remove the bentsectionsof pipe, dependingon the amount of resistanceencounteredfrom the

' waste material. Actual removalloads encounteredin the field was a maximumof 14,000 pounds force. The waste resisted the movement of the air lance orthermocouplesmore than expected.

CONCLUSIONS

The air lance and thermocoupletree removalwas successfullycompletedinthe field on Tank 241-SY-I01. The assembly removaloperationwas completedbasicallyin severalphases: site preparation,cuttingoff the assembly tops,waste-cakeball removal, assemblypulling, and packagingthe assemblies inreceiversfor disposal. The air lances were removedwithout problems.However, during removal, a thermocoupletree assemblybroke at two weldedareas. The less-than-full-penetrationwelds connectingthe sectionsof theassemblybroke near the bottom of the riser. Special retrievalequipmentwasthen developedon a fast-trackprocessand adaptedto the removalequipment.The specialretrievalequipmentwas remotely latchedonto the brokenassembliesto allow the removaloperationto be completed.

Page 9: ' Hanford Site Tank 241-SY-101, Damaged Equipment Removal

WHC-SA-1976-FP

Figure 1. Air Lance Bent at Approximately40 Degrees Due to Movement ofRadioactiveTank Waste.

Page 10: ' Hanford Site Tank 241-SY-101, Damaged Equipment Removal

WHC-SA-1976-FP

Figure 2. Tank Waste Material Dried on Air Lance, IncludingLarge-DiameterCake Bal l.

Page 11: ' Hanford Site Tank 241-SY-101, Damaged Equipment Removal

g

•a,_e_paeH)lUel-Ul5U.LAOmB_I_0_ pBU6.LSB(],_aLLnd5u.tse3Le.LO,_ammo3pa.t_.Lpog"£ a,_nB.L..l

d.-I-9L6I-VS-3HM

Page 12: ' Hanford Site Tank 241-SY-101, Damaged Equipment Removal

WHC-SA-1976-FP

Figure 4. Field OperationsInstallinga 66-ft-longReceiver into the SShieldedGlovebox Containingthe PullingEquipmentis Shown Below the S

Page 13: ' Hanford Site Tank 241-SY-101, Damaged Equipment Removal
Page 14: ' Hanford Site Tank 241-SY-101, Damaged Equipment Removal

WHC-SA-1976-FP

DISTRIBUTION

Number of CODies

ONSITE

, 26 WestinqhouseHanford Company

H. G. Barrus H5-72D. E. Legare H5-70P. A. Titzler (20) H5-70Central Files L8-04InformationRelease

Administration(3) A3-36

Distr-1

Page 15: ' Hanford Site Tank 241-SY-101, Damaged Equipment Removal

WHC-SA-Ig76-FP

This pageintentionallyleft blank.

Distr-2

Page 16: ' Hanford Site Tank 241-SY-101, Damaged Equipment Removal

j J!

Page 17: ' Hanford Site Tank 241-SY-101, Damaged Equipment Removal