St. Elizabeth Fire Protection System 100% Fire Sprinkler Coverage 100% Heat/Smoke Detector Coverage
22

Familiarization of system Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen Unique Fire Protection Element Smoke Curtain.

Dec 22, 2015

Download

Documents

Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.

St. Elizabeth Fire Protection System

100% Fire Sprinkler Coverage 100% Heat/Smoke Detector Coverage

Page 2: Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.

Course Objectives Familiarization of system Locations of:

HydrantsFDCKnox BoxFACPSprinkler Riser RoomLiquid Oxygen

Unique Fire Protection Element Smoke Curtain Kitchen Hood System Standpipe Pre Action & VESDA Systems

Page 3: Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.

Hospital GroundsNORTHAmbulance Entrance

Main Entrance

Sprinkler Riser Room

Fire Dept. Connection

Knox Box

Enunciator Panel

Standpipe

Roof Acess

Page 4: Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.

Fire Department ConnectionLocated on Jensen St. Side Of Hospital

You will need the knox key to

remove the caps on the FDC

Page 5: Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.

To access Key use door code followed by

#

Knox Box

Page 6: Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.

Fire Alarm Control Panels

FACP located on floor one

in boiler room.

Annunciator panels

located on all floors.

Printer located near FACP prints

all activity associated with

fire systems

Page 7: Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.

BRAIN(Fire Pump Control Panel)

HEART(FIRE PUMP)

CPR

Blood Vessels(Piping)

Nervous System

Page 8: Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.

Sprinkler Riser Room

Water In

Pump Bypass Always Open

Fire Pump

Jockey Pump

Test Header Always Closed

Back To Riser

Double Check Valve

Floor 1 Riser/Standpip

e

Floor 2,3 & Roof

Riser/Standpipe

Page 9: Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.

Standpipe

Isolation Valve Will Turn off

water to floors 2 & 3

Isolation Valve Isolates

2nd floor Sprinklers

Flow Switch Floor 2

2 ½ Inch Connection

Page 10: Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.

StandpipeNorth Stairwell

2 ½ “ Connection

Both Are Supplied From Sprinkler

System

Page 11: Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.

Roof Top

Roof Access South

Stairwell

RoofStandpip

e

PIV

PIV

Dry Beyond Valve

Ceiling of south Stairwell

Roof Standpipe

Page 12: Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.

Kitchen Hood SystemKitchen Hood Flow Switch Is Tied Into The Fire Alarm System

Page 13: Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.
Page 14: Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.

Fire Curtain Separation

Located outside every elevator door. Curtains are activated with fire

alarm or sprinkler water flow

Page 15: Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.
Page 16: Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.

Located near stairway/ atrium on floor one.

Activated with fire alarm or water flow. In place to

prevent smoke migration between

floors.

Page 17: Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.
Page 18: Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.

Generator

Generator Located Here

Page 19: Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.

Underground Fuel Storage

Underground tank contains approximately 3,000 gallons of

diesel fuel.

Page 20: Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.

Liquid Oxygen Tank

Page 21: Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.

Pre-Action System & VESDA System

Pre Action Located In

ClosetFloor 2VESDA Located On Floor 1 in

MRI Area

Loss Of Air Pressure Plus Activation Of

Smoke Detector Required For

Water To Enter The Sprinkler

Piping

Air Compressor

SolenoidHolds Water

BackVESDA Similar To Pre Action. Goes Into Pre Alarm Notifying Staff

Well In Advance Of Actual Fire.

Page 22: Familiarization of system  Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen  Unique Fire Protection Element Smoke Curtain.