(A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 1 of 12 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 JM TEST SYSTEMS, INC. Calibration Laboratory Division 1600 Watterberg Way Alexandria, LA 71303 Jerry Kraus Phone: 225 925 2029 x 3028 CALIBRATION Valid To: February 28, 2015 Certificate Number: 1995.02 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following calibrations 1 : I. Electrical – DC/Low Frequency Parameter/Equipment Range CMC 2, 3, 4 () Comments DC Voltage – Generate (0 to 220) mV (0.22 to 2.2) V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1100) V 13 μV/V + 0.6 μV 8.6 μV/V + 1.0 μV 8.2 μV/V + 3.5 μV 8.2 μV/V + 6.5 μV 9.8 μV/V + 80 μV 11 μV/V + 500 μV Fluke 5700A DC Voltage – Measure (0 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V 32 μV/V + 0.3 μV 21 μV/V + 0.3 μV 21 μV/V + 0.5 μV 32 μV/V + 30 μV 33 μV/V + 100 μV Agilent 3458A
13

& ANSI/NCSL Z540-1-1994 CALIBRATION ISO 17025 certificate and... · 2017. 4. 7. · (A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 1 of 12 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Dec 16, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: & ANSI/NCSL Z540-1-1994 CALIBRATION ISO 17025 certificate and... · 2017. 4. 7. · (A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 1 of 12 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

(A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 1 of 12

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994

JM TEST SYSTEMS, INC. Calibration Laboratory Division

1600 Watterberg Way Alexandria, LA 71303

Jerry Kraus Phone: 225 925 2029 x 3028

CALIBRATION

Valid To: February 28, 2015 Certificate Number: 1995.02 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following calibrations1: I. Electrical – DC/Low Frequency

Parameter/Equipment

Range CMC2, 3, 4 ()

Comments

DC Voltage – Generate

(0 to 220) mV (0.22 to 2.2) V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1100) V

13 µV/V + 0.6 µV 8.6 µV/V + 1.0 µV 8.2 µV/V + 3.5 µV 8.2 µV/V + 6.5 µV 9.8 µV/V + 80 µV 11 µV/V + 500 µV

Fluke 5700A

DC Voltage – Measure

(0 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V

32 µV/V + 0.3 µV 21 µV/V + 0.3 µV 21 µV/V + 0.5 µV 32 µV/V + 30 µV 33 µV/V + 100 µV

Agilent 3458A

Page 2: & ANSI/NCSL Z540-1-1994 CALIBRATION ISO 17025 certificate and... · 2017. 4. 7. · (A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 1 of 12 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

(A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 2 of 12

Parameter/Equipment

Range CMC2, 3, 4, 5 ()

Comments

DC Current – Generate

(0 to 220) μA (0.22 to 22) mA (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A (2.2 to 11) A (11 to 110) A (110 to 550) A

60 µA/A + 8 nA 59 µA/A + 8 nA 61 µA/A + 80 nA 73 µA/A + 0.8 µA 110 µA/A + 2.5 µA 0.073 % + 330 µA 0.26 % of output + 0.5A 0.27 % of output + 0.5A

Fluke 5700A Fluke 5500A Fluke 5500A + 50 turn coil

DC Current – Measure

(10 to 100) μA (0.10 to 1.0) mA (1.0 to 10) mA (10 to 100) mA (0.10 to 1) A (1 to 10) A (10 to 100) A

49 µA/A + 0.8 nA 48 µA/A + 5 nA 66 µA/A + 50 nA 77 µA/A + 0.5 µA 0.02 % + 10 µA 0.014 % 0.064 %

Agilent 3458A Guildline 9211A shunt & Agilent 3458A

DC Power – Generate

(0 to 1) mW (1 to 10) mW (10 to 100) mW (0.1 to 1) W (1 to 10) W (10 to 100) W (100 to 300) W (300 to 2000) W (2000 to 11 000) W

0.020 % 0.015 % 0.014 % 0.015 % 0.015 % 0.019 % 0.019 % 0.040 % 0.080 %

Fluke 5500A

Page 3: & ANSI/NCSL Z540-1-1994 CALIBRATION ISO 17025 certificate and... · 2017. 4. 7. · (A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 1 of 12 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

(A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 3 of 12

Parameter/Equipment

Range CMC2, 3, 5 ()

Comments

Resistance –

Fixed Points

0.001 0.01 0.1 0 1 1.9 10 19 100 190 1 k 1.9 k 10 k 19 k 100 k 190 k 1 M 1.9 M 10 M 19 M 100 M

0.062 % 0.014 % 0.013 % 41 µ 0.013 % 0.019 % 34 µΩ/Ω 35 µΩ/Ω 20 µΩ/Ω 21 µΩ/Ω 15 µΩ/Ω 15 µΩ/Ω 14 µΩ/Ω 14 µΩ/Ω 17 µΩ/Ω 17 µΩ/Ω 26 µΩ/Ω 29 µΩ/Ω 54 µΩ/Ω 63 µΩ/Ω 0.016 %

Guildline 9211A shunt Fluke 5700A

Resistance – Generate

(0 to 11) Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (0.33 to 1.1) kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (0.33 to 1.1) MΩ (1.1 to 33) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ

0.017 % + 0.006 Ω 0.019 % + 0.01 Ω 0.011 % + 0.01 Ω 0.011 % + 0.01 Ω 0.011 % + 0.06 Ω 0.011 % + 0.06 Ω 0.011 % + 0.6 Ω 0.011 % + 0.6 Ω 0.013 % + 6 Ω 0.015 % + 6 Ω 0.018 % + 55 Ω 0.021 % + 55 Ω 0.071 % + 0.55 kΩ 0.13 % + 0.55 kΩ 0.59 % + 5.5 kΩ 0.72 % + 17 kΩ

Fluke 5500A

Page 4: & ANSI/NCSL Z540-1-1994 CALIBRATION ISO 17025 certificate and... · 2017. 4. 7. · (A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 1 of 12 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

(A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 4 of 12

Parameter/Equipment

Range CMC2, 3, 4, 5 ()

Comments

Resistance – Measure

(0 to 10) (10 to 100) (0.1 to 1) k (1 to 10) k (10 to 100) k (0.1 to 1) M (1 to 10) M (0 to 100) M

65 µΩ/Ω + 50 µΩ 48 µΩ/Ω + 0.5 mΩ 35 µΩ/Ω + 0.5 mΩ 35 µΩ/Ω + 5 mΩ 36 µΩ/Ω + 50 mΩ 39 µΩ/Ω + 2 Ω 0.013 % + 100 Ω 0.063 % + 1 kΩ

Agilent 3458A

Capacitance – Generate

(0.33 to 0.5) nF (0.5 to 1.1) nF (1.1 to 3.3) nF (3.3 to 11) nF (11 to 33) nF (33 to 110) nF (110 to 330) nF (0.33 to 1.1) µF (1.1 to 3.3) µF (3.3 to 11) µF (11 to 33) µF (33 to 110) µF (110 to 330) µF (330 to 1100) µF

1.1 % + 0.01 nF 0.69 % + 0.01 nF 0.61 % + 0.01 nF 0.59 % + 0.01 nF 0.3 % + 0.1 nF 0.3 % + 0.1 nF 0.3 % + 0.3 nF 0.3 % + 1 nF 0.44 % + 3 nF 0.44 % + 10 nF 0.49 % + 30 nF 0.6 % + 100 nF 0.86 % + 300 nF 1.3 % + 300 nF

Fluke 5500A

Page 5: & ANSI/NCSL Z540-1-1994 CALIBRATION ISO 17025 certificate and... · 2017. 4. 7. · (A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 1 of 12 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

(A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 5 of 12

Parameter/Equipment

Range CMC2 ()

Comments

Electrical Calibration of Thermocouple Indicators – Generate & Measure

Type E Type J Type K

Type T

(-250 to -100) C (-100 to -25) C (-25 to 350) C (350 to 650) C (650 to 1000) C (-210 to -100) C (-100 to -30) C (-30 to 150) C (150 to 760) C (760 to 1200) C (-200 to -100) C (-100 to -25) C (-25 to 120) C (120 to 1000) C (1000 to 1372) C (-250 to -150) C (-150 to 0) C (0 to 120) C (120 to 400) C

0.59 C 0.23 C 0.21 C 0.23 C 0.28 C 0.34 C 0.23 C 0.21 C 0.24 C 0.3 C 0.4 C 0.25 C 0.23 C 0.33 C 0.48 C 0.74 C 0.31 C 0.23 C 0.21 C

Fluke 5500A

Electrical Calibration of RTD Indicators – Generate

Pt 385, 100

(-200 to -80) C (-80 to 0) C (0 to 100) C (100 to 300) C (300 to 400) C (400 to 630) C (630 to 800) C

0.06 C 0.06 C 0.08 C 0.11 C 0.12 C 0.14 C 0.27 C

Fluke 5500A

Page 6: & ANSI/NCSL Z540-1-1994 CALIBRATION ISO 17025 certificate and... · 2017. 4. 7. · (A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 1 of 12 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

(A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 6 of 12

Parameter/Range

Frequency CMC2, 3 ()

Comments

AC Voltage – Generate

Up to 2.2 mV (2.2 to 22) mV (22 to 220) mV (0.22 to 2.2) V

(10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz

0.21 % + 4.5 µV 0.13 % + 4.5 µV 0.11 % + 4.5 µV 0.16 % + 4.5 µV 0.22 % + 7 µV 0.59 % + 13 µV 0.56 % + 25 µV 1.5 % + 25 µV 0.069 % + 5 µV 0.030 % + 5 µV 0.022 % + 5 µV 0.048 % + 5 µV 0.11 % + 7 µV 0.16 % + 12 µV 0.22 % + 25 µV 0.43 % + 25 µV 0.070 % + 13 µV 0.025 % + 8 µV 0.013 % + 8 µV 0.044 % + 8 µV 0.10 % + 25 µV 0.13 % + 25 µV 0.20 % + 35 µV 0.41 % + 80 µV 0.060 % + 80 µV 0.020 % + 25 µV 0.011 % + 6 µV 0.015 % + 16 µV 0.030 % + 70 µV 0.054 % + 130 µV 0.13 % + 350 µV 0.33 % + 850 µV

Fluke 5700A

Page 7: & ANSI/NCSL Z540-1-1994 CALIBRATION ISO 17025 certificate and... · 2017. 4. 7. · (A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 1 of 12 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

(A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 7 of 12

Parameter/Range

Frequency CMC2, 3, 4 ()

Comments

AC Voltage – Generate (cont.)

(2.2 to 22) V

(22 to 220) V

(220 to 250) V

(220 to 1100) V

(10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (15 to 50) Hz 50 Hz to 1 kHz

0.058 % + 800 µV 0.019 % + 250 µV 90 µV/V + 60 µV 0.015 % + 160 µV 0.030 % + 350 µV 0.065 % + 1.5 mV 0.16 % + 4.3 mV 0.38 % + 8.5 mV 0.062 % + 8 mV 0.031 % + 2.5 mV 0.028 % + 0.8 mV 0.034 % + 3.5 mV 0.077 % + 8 mV 0.23 % + 90 mV 0.59 % + 90 mV 0.045 % + 16 mV 97 µV/V + 3.5 mV

Fluke 5700A

AC Voltage – Measure

(0 to 10) mV (10 to 100) mV

(1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz

0.08 % + 3 µV 0.06 % + 1.1 µV 0.09 % + 1.1 µV 0.46 % + 1.1 µV 0.78 % + 1.1 µV 4.7 % + 2 µV 0.011 % + 4 µV 0.015 % + 2 µV 0.03 % + 2 µV 0.013 % + 2 µV 0.024 % + 2 µV 0.41 % + 10 µV 1.2 % + 10 µV

Agilent 3458A

Page 8: & ANSI/NCSL Z540-1-1994 CALIBRATION ISO 17025 certificate and... · 2017. 4. 7. · (A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 1 of 12 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

(A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 8 of 12

Parameter/Range

Frequency CMC2, 4 ()

Comments

AC Voltage – Measure (cont)

(0.10 to 1.0) V

(1 V to 10) V

(10 to 100) V

(100 to 750) V

(1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz

0.011 % + 40 µV 0.016 % + 20 µV 0.03 % + 20 µV 0.05 % + 20 µV 0.011 % + 20 µV 0.36 % + 100 µV 1.2 % + 100 µV 0.01 % + 0.4 mV 0.012 % + 0.2 mV 0.02 % + 0.2 mV 0.04 % + 0.2 mV 0.1 % + 0.2 mV 0.37 % + 1 mV 1.2 % + 1 mV 0.025 % + 4 mV 0.025 % + 2 mV 0.03 % + 2 mV 0.05 % + 2 mV 0.16 % + 2 mV 0.47 % + 10 mV 1.8 % + 10 mV 0.048 % + 40 mV 0.048 % + 20 mV 0.08 % + 20 mV 0.14 % + 20 mV 0.35 % + 20 mV

Agilent 3458A

Page 9: & ANSI/NCSL Z540-1-1994 CALIBRATION ISO 17025 certificate and... · 2017. 4. 7. · (A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 1 of 12 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

(A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 9 of 12

Parameter/Range

Frequency CMC2, 3 ()

Comments

AC Current – Generate

(10 to 200) µA 220 µA to 2.2 mA (2.2 to 22) mA (22 to 220) mA 220 mA to 2.2 A (2.2 to 11) A

(11 to 110) A (110 to 550) A

(10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 20 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz

0.082 % + 25 nA 0.042 % + 20 nA 0.018 % + 16 nA 0.74 % + 40 nA 0.2 % + 80 nA 0.082 % + 40 nA 0.042 % + 35 nA 0.017 % + 35 nA 0.07 % + 0.4 µA 0.19 % + 0.8 µA 0.082 % + 0.4 µA 0.041 % + 0.35 µA 0.017 % + 0.35 µA 0.07 % + 4 µA 0.19 % + 8 µA 0.083 % + 4 µA 0.042 % + 3.5 µA 0.017 % + 3.5 µA 0.07 % + 40 µA 0.19 % + 80 µA 0.077 % + 35 µA 0.12 % + 80 µA 1 % + 0.16 mA 0.08 % + 2 mA 0.12 % + 2 mA 0.39 % + 2 mA 0.26 % of output + 0.5 A 0.28 % of output + 0.5 A 0.26 % of output + 0.5 A

Fluke 5700A Fluke 5500A Fluke 5500A + 50 turn coil

Page 10: & ANSI/NCSL Z540-1-1994 CALIBRATION ISO 17025 certificate and... · 2017. 4. 7. · (A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 1 of 12 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

(A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 10 of 12

Parameter/Range

Frequency CMC2, 4 ()

Comments

AC Current – Measure

(10 to 100) μA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA

(0.1 to 1) A

(1 to 2) A (2 to 20) A (20 to 100) A

(10 to 20) Hz (20 to 40) Hz (40 to 100) Hz (0.1 to 5) kHz (10 to 20) Hz (20 to 40) Hz (40 to 100) Hz (0.1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz (40 to 100) Hz (0.1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz (40 to 100) Hz (0.1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz (40 to 100) Hz (0.1 to 5) kHz (5 to 10) kHz 40 Hz to 10 kHz 40 Hz to 1 kHz (1 to 5) kHz (45 to 65) Hz

0.47 % + 0.03 µA 0.18 % + 0.03 µA 0.07 % + 0.03 µA 0.07 % + 0.03 µA 0.47 % + 0.2 µA 0.18 % + 0.2 µA 0.08 % + 0.2 µA 0.04 % + 0.2 µA 0.08 % + 0.2 µA 0.47 % + 2 µA 0.18 % + 2 µA 0.08 % + 2 µA 0.04 % + 2 µA 0.08 % + 2 µA 0.47 % + 20 µA 0.18 % + 20 µA 0.08 % + 20 µA 0.04 % + 20 µA 0.08 % + 20 µA 0.47 % + 200 µA 0.2 % + 200 µA 0.11 % + 200 µA 0.13 % + 200 µA 0.36 % + 200 µA 0.12 % of range 0.12% of range 0.58 % of range 0.13% of range

Agilent 3458A Valhalla Scientific 2575A wideband current shunt & Agilent 3458A

Page 11: & ANSI/NCSL Z540-1-1994 CALIBRATION ISO 17025 certificate and... · 2017. 4. 7. · (A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 1 of 12 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

(A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 11 of 12

Parameter/Range

Frequency CMC2, 5 ()

Comments

AC Power – Generate (PF=1)

(10 to 100) µW (0.1 to 1) mW (1 to 10) mW (10 to 100) mW (0.1 to 3.3) W (3.3 to 33) W (33 to 3300) W (3300 to 11 000) W

(45 to 65) Hz

0.35 % 0.25 % 0.15 % 0.14 % 0.13 % 0.12 % 0.11 % 0.12 %

Fluke 5500A

II. Mechanical

Parameter/Equipment

Range CMC2, 5 ()

Comments

Torque Testers

(0 to 2000) ft·lbf 0.17 % Torque arms and weights

Torque Wrenches

(2.5 to 750) in·lbf (12.5 to 2000) ft·lbf

0.6 % 0.6 %

CDI 2000 torque calibrator

Force Gauges

(5 to 62) lbf (62 to 2000) lbf (1 to 500) lbf

0.24 % 0.23 % 0.29 %

CDI 2000 torque/force calibrator Class “T” weights

III. Time & Frequency

Parameter/Equipment

Range CMC2 ()

Comments

Frequency – Time Base

10.0000000 MHz 4.0 parts in 1011 GPS steered Rubidium

OCXO continuously in GPS locked state

Page 12: & ANSI/NCSL Z540-1-1994 CALIBRATION ISO 17025 certificate and... · 2017. 4. 7. · (A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 1 of 12 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

(A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 12 of 12

Parameter/Equipment

Range CMC2 ()

Comments

Frequency – Measuring Equipment

10.0000000 MHz 4.0 parts 1011 Uses phase comparison

system to compare test signal with time base 10 MHz output signal

Frequency – Measure

10 mHz to 100 MHz 10 MHz to 18 GHz

4.0 parts in 1011 + counter resolution of 0.02 Hz at 100 MHz frequency input 4.0 parts in 1011 + counter resolution (resolution = 2 Hz)

HP 5335A counter slaved to time base – GPS steered Rubidium OCXO EIP 575 counter slaved to time base – GPS steered Rubidium OCXO

________________________________________

1 This laboratory offers commercial calibration service and field calibration services. 2 Calibration and Measurement Capability (CMC) is the smallest uncertainty of measurement that a

laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal Generate . Calibration and Measurement Capabilities represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.

3 Fluke 5700A and 5500A CMCs are based upon the temperature the standard was calibrated (tcal ± 5 oC) and assuming the instrument is zeroed at least every seven days or when the ambient temperature changes more than 5 oC. For Resistance, a zero calibration is performed at least every 12 hours within ± 1 oC of use. For AC Current, CMCs are determined with the LCOMP off. CMCs are also based upon 1-year floor specifications. CMCs are expressed as either a specific value that covers the full range or as a fraction of the reading plus a fixed floor specification.

4 Agilent 3458A CMCs are based upon the temperature the standard was calibrated (tcal ± 5 oC) and an

auto calibration (ACAL) was performed within the previous 24 hours (± 1 oC of ambient temperature.) CMCs are also based upon 1-year floor specifications. CMCs are expressed as either a specific value that covers the full range or as a combination of the fraction of the reading/output plus a range specification.

5 In the statement of CMC, percentages are percentages of reading, unless otherwise indicated.

Page 13: & ANSI/NCSL Z540-1-1994 CALIBRATION ISO 17025 certificate and... · 2017. 4. 7. · (A2LA Cert. No. 1995.02) Revised 11/24/2014 Page 1 of 12 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

A2LA has accredited

JM TEST SYSTEMS, INC. Alexandria, LA

for technical competence in the field of

Calibration

This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration Laboratories. This laboratory also meets the requirements of ANSI/NCSL Z540-1-1994 and any additional program requirements in the field of calibration. This accreditation demonstrates technical competence for a defined scope and the

operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009).

Presented this 21st day of March 2013.

_______________________ President & CEO For the Accreditation Council Certificate Number 1995.02 Valid to February 28, 2015 Revised November 24, 2014

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.