Top Banner
目目 8 in 1 Sensor ◆8 in 1 Sensor Unique Features ●Built in PIR motion sensor and light intensity sensor ●Built in 2 Dry Input Ports ●Built in 32 Logics ●Infrared receiver ●Infrared transmitter ●Built in security alarm logic (work with Security Module)
29

目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

Jan 18, 2018

Download

Documents

1.Input key target Qty 3.Select IR code from database 2.Select key no. 4.Downlaod 5.Confirm IR Code download
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

目录8 in 1 Sensor

◆8 in 1 SensorUnique Features

●Built in PIR motion sensor and light intensity sensor●Built in 2 Dry Input Ports●Built in 32 Logics●Infrared receiver●Infrared transmitter●Built in security alarm logic (work with Security Module)

Page 2: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

Subnet ID and Device ID

Remark

MAC Address

Basic information

Page 3: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

1.Input key target Qty

3.Select IR code from database

2.Select key no.

4.Downlaod

5.Confirm

IR Code download

Page 4: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

6.Select key no.

7. Select key stroke type

IR Code testing 8. Press Transmit and test

Page 5: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

IR Code receiving

1.Configuration same as switch panel, first select key no. of remoter

2.Setup the mode for the key

Page 6: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

3.Select key control mode

4.Save

IR Code receiving

Page 7: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

5.Select control target

IR Code receiving

Page 8: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

6.Input target Subnet ID, Device ID and Parameter

7. Save

IR Code receiving

Page 9: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

IR Code receiving

8. Align the Remoter with 8 in 1 sensor, press the key and test

Page 10: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

1. Select a Logic Block (Max 32 blocks)

2.Input Remark and charge the status to Valid, default is invalid

3. Save

4.Click Edit to setup menu

Automation logics configuration

Page 11: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

Automation logics configuration

Current statusSelect logic condition Select logics

relation

Command

Page 12: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

Application

In case of a meeting room has below requirements:

1.When people open the door and come in the meeting room, the lights open automatically2. After people come in the room for more than 1 minute, open the AC and change the temperature to 25℃3. After people leave the room for 1 minute, off the lights and the temperature increase 2℃4.After people leave the room for 3 minute,turn off the AC automaticallyWe need 4 logic blocks to accomplish the requirements above

Page 13: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

1.When people open the door and come in the meeting room, the lights open automatically

Requirements

Page 14: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

2. Input remark and change current status to Valid

3.Save

4.Edit Logic setting

1.Select a Logic block

Page 15: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

Requirement: When people open the door and come in the meeting room, the lights open automatically

5.If the door installed a magnetic contact and connect to 8 in 1 sensor, change condition to disconnect

6. Select Motion sensor and Condition movement

7. Change delay time to 0 sec.

8.Select relation And

9.Save logic setting

10.Click Command to select control target

Page 16: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

11. Input light channel to open

12.Save

Requirement: When people open the door and come in the meeting room, the lights open automatically

Page 17: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

2. After people come in the room for more than 1 minute, open the AC and change the temperature to 25℃

Requirements

Page 18: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

Requirement: After people come in the room for more than 1 minute, open the AC and change the temperature to 25℃

2. Input remark and change current status to Valid

3.Save

4.Edit Logic setting

1.Select a Logic block

Page 19: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

5.If the door installed a magnetic contact and connect to 8 in 1 sensor, change condition to disconnect

6. Select Motion sensor and Condition movement

7. Change delay time to 1 minutes

8.Select relation And

9.Save logic setting

10.Click Command to select control target

Requirement: After people come in the room for more than 1 minute, open the AC and change the temperature to 25℃

Page 20: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

12.Input target with the subnet ID and device ID of the sensor. Type “Infrared remote sensor", parameter 1 “3”, parameter 2 “on”

13.SaveRequirement: After people come in the room for more than 1 minute, open the AC and change the temperature to 25℃

11.Before set the control target, please go to IR transmitter page and record the key no.(3) of 25℃

Page 21: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

3. After people leave the room for 1 minute, off the lights and the temperature increase 2℃

Requirements

Page 22: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

2. Input remark and change current status to Valid

3.Save

4.Edit Logic setting

1.Select a Logic block

Requirement: After people leave the room for 1 minute, off the lights and the temperature increase 2℃

Page 23: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

Requirement: After people leave the room for 1 minute, off the lights and the temperature increase 2℃

5.Select Motion sensor and Condition No movement

6.Change delay time to 1 minutes

7.Select either AND or OR because there’s only one logic condition

8.Save logic setting

9.Click Command to select control target

Page 24: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

10.Input target with the subnet ID and device ID of the sensor. Type “Infrared remote sensor", parameter 1 “5”, parameter 2 “on”

11.Save Requirement: After people leave the room for 1 minute, off the lights and the temperature increase 2℃

Page 25: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

4.After people leave the room for 3 minute, turn off the AC automatically

Requirements

Page 26: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

2. Input remark and change current status to Valid

3.Save

4.Edit Logic setting

1.Select a Logic block

Requirement: After people leave the room for 3 minute, turn off the AC automatically

Page 27: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

5.Select Motion sensor and Condition No movement

6.Change delay time to 3 minutes

7.Select either AND or OR because there’s only one logic condition

8.Save logic setting

9.Click Command to select control target

Requirement: After people leave the room for 3 minute, turn off the AC automatically

Page 28: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

10.Input control target

11. SaveRequirement: After people leave the room for 3 minute, turn off the AC automatically

Page 29: 目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.

Complete