사양승인원 제품명 : 순간온수모듈 모델명 : IHM-2216NP 납품처 : 검 토 심 사 승 인 ( 주) 인터텍 경기도 화성시 동탄면 송리 동탄기흥로 15 TEL : (031) 206-2626 FAX : (031)8015-2625
사 양 승 인 원
제품명 :
순 간 온 수 모 듈
모델명 : I H M - 2 2 1 6 N P
납품처 :
검
토
심
사
승
인
(
주)
인터텍
경기도
화성시
동탄면
송리
동탄기흥로 15TEL : (031) 206-2626FAX : (031)8015-2625
2/18 (
주)
인
터
텍 A4(210×297)
사 양 승 인 원
관 리
이 력
제품명:
비데용
순간온수모듈
모델명:IHM-2216N
개정
번호
유 효 일 자
개 정 내 역
담 당
검 토
승 인
3/18 (
주)
인
터
텍 A4(210×297)
<
차
례 >
1.
적용범위 ··································································· 4
2.
기계적
특성 ····························································· 4
3. Characteristics ····················································· 4
4.
통신
제어
사양 ······················································· 5
5.
외부
결선도 ····························································· 7
6.
주요
부품 ································································· 8
7.
부속
정격 ······························································· 10
8.
동작성능 ································································· 11
9. Part Number Decoder ··········································· 16
10. Label ······································································· 16
11. IHM Simulator (PC Version) ····························· 17
12.
품질검사 Jig ························································· 17
(
주 )
인 터 텍
연
구
소
생산기술
품질관리
대 표 이 사
작
성
검
토
승
인
검
토
검
토
승
인
4/18 (
주)
인
터
텍 A4(210×297)
1.
적용범위
본
사양서는
가정용
비데의
순간온수모듈 IHM Series
에
적용한다.
2.
기계적
특성
2.1
형상
및
치수
외관은
도면(
도번 IMO1-8001)
를
만족한다.
2.2
외관
세라믹히터,
입수온도센서,
출수온도센서,
유량센서, PCB ASS'Y
등
구성품의
취부상태가
양호
해야
하며,
이물질,
긁힘
등이
없이
외관상
양호해야
한다.
2.3
적용
수압
수압은 0.5~1.5/
내에서
적용한다.
2.4
취부
방법
취부는
별첨
도면(FIX-ASSY BODY)
에
따르며
유동이
없어야
한다.
3. Characteristics
3.1 AC Characteristics
Characteristics Model/Condition Unit Min Typ Max
AC Supply Voltage IHM-1012N V 90 100 110
IHM-1112N V 100 110 120
IHM-1212N V 110 120 130
IHM-1214N V 110 120 130
IHM-2216N V 200 220 240
IHM-2228N V 200 220 240
AC Frequency Hz - 50/60 -
Heater Power Consumption IHM-1012N W - 1200 -
(Heater
정격) IHM-1112N W - 1200 -
IHM-1212N W - 1200 -
IHM-1214N W - 1400 -
IHM-2216N W - 1600 -
IHM-2228N W - 2800 -
Storage Temperature 0 20 40
3.2 DC Characteristics
Characteristics Model/Condition Unit Min Typ Max
DC Supply Voltage
비데에서
공급 V 4.8 5.0 5.2
Current Consumption mA - 10 30
Communication Speed bps - 2400 -
5/18 (
주)
인
터
텍 A4(210×297)
3.3 Temperature Characteristics
Characteristics Condition Unit Min Typ Max
Input Water Temperature 5 20 40
Output Water Temperature 0.5
간격
설정 30 - 42
Need Time To Reach Ttarget
1200W
급T 30 540mℓ/min1600W
급T 30 640mℓ/min
sec - 6 10
Stabilization on Ttarget -1 ± 0.5 +1
※ Ttarget : Target Temperature (
목표온도)
4.
통신
제어
사양
4.1
통신방식
통신방식 UART
통신
전송속도 2400 bps
Parity No
Stop Bit 1 bit
Data Flow Master :
비데본체 ↔ Slave : IHM Series
4.2
통신 Flow
비데 →
순간온수모듈
순간온수모듈 →
비데
5ms
Min 200ms
※ 1. Master
인
비데
본체가
송신을
하면
순간온수모듈은 Slave
로 5ms
후에
응답한다.
2. Master
의
최소
송신
주기는 200ms
이다.(500ms
를
추천함.)
6/18 (
주)
인
터
텍 A4(210×297)
4.3
통신 Data
4.3.1
비데 →
순간온수모듈
ST Add Mode Data1 Data2 Data3 Data4 Data5 Data6 Data7 Data8 CHK END
32h F0h 81h
1)
bit0
:on/off
2)
설정
온도
H
2)
설정
온도
L
0 0 0 0 0
Add~
Data8
까지의
Xor
34h
1) Bit0=0
면 OFF, 1
일
경우 ON
2)
설정온도가 20
도
이하일
경우
강제로 20
도로
조정
설정온도가 43
도
이상일
경우
강제로 43
도로
조정
4.3.2
순간온수모듈 →
비데
ST Add Mode Data1 Data2 Data3 Data4 Data5 Data6 Data7 Data8 CHK END
32h 0Fh 01h
1)
bit0
:on/off
2)
Error
입력
온도
H
입력
온도
L
출력
온도
H
출력
온도
L
유량
센서
H
유량
센서
L
Add~
Data8
까지의
Xor
34h
1)
순간온수모듈이 OFF
상태면 0, ON
상태면 1
2) Error
bit 0 : Zerocross Interrupt
가
발생하지
않을
경우
bit 1 :
입수 Thermistor Error(Open)
bit 2 :
입수 Thermistor Error(Short)
bit 3 :
출수 Thermistor Error(Open)
bit 4 :
출수 Thermistor Error(Short)
bit 5 :
출수
온도
과승
4.3.3
정상통신일
경우 Rx
를 1
회
받을때
마다 50msec
동안 LED
점멸
4.3.4
입수센서 EEROR,
출수센서 EEROR
1) 3
초주기로 2
회
연속
점멸한다. 2) EEROR
조건이
해지되었을
경우 EEROR
가
해지
된다. 3)
입수 Open : -10
도,
입수 Short : 50
도 4)
출수 Open : -10
도,
출수 Short : 50
도
4.3.5 ZeroCrossing EEROR
1) 3
초주기로 3
회
연속
점멸한다. 2) 100msec
동안 ZeroCrossing
인터럽트가
한번도
들어오지
않을
경우 EEROR
가
된다. 3) ZeroCrossing
인터럽트가
들어오는
즉시 ZeroCrossing EEROR
는
해지
된다.
7/18 (
주)
인
터
텍 A4(210×297)
4.3.6
온도과승EEROR
1) 3
초주기로 4
회
연속
점멸한다. 2)
온수모듈
출수온도
기준으로 45
도이상이
되면
온도과승EEROR
가
발생한다. 3)
온도가 43
도이하가
되고
통신으로 Heater Off → Heater On
이
되는
순간에 EEROR
는
해지
된다. 4)
통신을
하지
않는
모델에서는
온도과승EEROR
가
없다.
4.3.7
통신 EEROR
1) 3
초주기로 5
회
연속
점멸한다. 2) 10
초
동안 Mater
쪽에서
통신포멧에
맞지
않은
신호가
들어오거나,
통신이
되지
않을
경우
통신EEROR
가
된다. 3)
통신을
하지
않는
모델에서는
통신EEROR
가
없다.
4.3.8
출수온도
비정상에러
1) 3
초주기로 6
회
연속
점멸한다. 1) Heate On
신호가
들어오지만
유량이 50cc
이하일
경우
유량미만
표시가
점멸된다. 2)
유량미만
표시는
통신으로
데이터를 Master
에게
보내지
않는다.
8/18 (
주)
인
터
텍 A4(210×297)
5.
외부
결선도
5.1
순간온수모듈에는 AC 2 Line
과 DC 4 Line
이
연결되어야
한다.
5.1.1 AC 2 Line
은 AC
가 Thermostat
과 PCB
상의 Connector(①)
에
연결되며,
5.1.2 DC 4 Line
은
비데
본체와 Connector(②)
로
연결된다.(+5V, RXD, TXD, GND)
No
구분
접속부위
비
고
1AC
Thermostat AC1 187 Tap Terminal
2 CN2 AC2 187 Tap Terminal
3
DC
CN11
의 1 +5V
SMW250-04/WHTYEONHO ELEC.
4 CN11
의 2 RXD
5 CN11
의 3 TXD
6 CN11
의 4 GND
① AC Water Outlet Thermistor
Water Inlet Thermistor
Flow sensor
② DC Ceramic Heater GND Connector Tx Data Rx Data +5Vdc Thermal cut-off Connector
9/18 (
주)
인
터
텍 A4(210×297)
6.
주요
부품
6.1 Ceramic Heater
6.1.1
제
조
사 :
인터텍
6.1.2
정
격 : 100Vac, 110Vac, 120Vac, 220Vac
6.1.3
히터용량 : 1200W, 1400W, 1600W, 2800W
6.1.4
저
항
정
격 Ambient Condition Resistance100Vac 1200W 6.4Ω± 5%110Vac 1200W 7.8Ω± 5%120Vac 1200W 22± 1 9.2Ω± 5%120Vac 1400W 6.3Ω± 5%220Vac 1600W 23.3Ω± 5%220Vac 2800W 13.3Ω± 5%
6.1.5
내
전
압 : AC 1800V 1sec
에
견딜
것. (
전극과
발열부위
수중
간에
측정)
6.1.6
절연저항 : 500Vdc 100
이상 (
전극과
발열부위
수중
간에
측정)
6.2 Hall Sensor(Flow Sensor)
6.2.1
제
조
사 : DIODE
6.2.2
품
명 : Bipolar Hall Effect Latch Sensor
6.2.3
모
델
명 : AH173, AH373
6.3 Water Inlet Thermistor Ass'y
6.3.1
제
조
사 : SHINSHIN ELECTRONIC INDUSTRY
6.3.2
모
델
명 : R842H34FCJ-I219
6.3.3
규
격 : R50 = 3.485KΩ±2%
6.3.4
내
전
압 : AC 1800V 1mA 1sec
6.3.5
절연저항 : 500Vdc 100
이상
6.4 Water Outlet Thermistor Ass'y
6.4.1
제
조
사 : SHINSHIN ELECTRONIC INDUSTRY
6.4.2
모
델
명 : G349J39GES-I218
6.4.3
규
격 : R25 = 49.12KΩ±3%
6.4.4
내
전
압 : AC 1800V 1mA 1sec
6.4.5
절연저항 : 500Vdc 100
이상
10/18 (
주)
인
터
텍 A4(210×297)
6.5 Thermostat(1200~1600W
급) (
자동복귀형
변경
가능)
6.5.1
제
조
사 : KYUNG IN ELECTRONICS
6.5.2
모
델
명 : NT-102NA (Menual Reset Type)
6.5.3
규
격 : 125Vac 15A / 230Vac 10A
6.5.4
정격
작동
온도 : (OFF) 48±3
6.5.5
내
전
압 : AC 1800V 1mA 1sec
6.5.6
절연저항 : 500Vdc 100
이상
6.5.7 VDE Approved File No : 14728-4510-0002
6.5.8 UL Approved File No : E110152
6.6 Thermal Cut-Off(1200~1600W
급)
6.6.1
제
조
사 : DONG-YANG ELECTRONICS
6.6.2
모
델
명 : DF-77S
6.6.3
규
격 : 250Vac 15A
6.6.4
정격
작동
온도(Tf) : 77
6.6.5 VDE Approved File No : 40017388
6.6.6 UL Approved File No : E117626
6.6.7 CCC Approved File No : 2003010205079617
6.7 Triac(1200~1600W
급)
6.7.1
제
조
사 : RENESAS
6.7.2
모
델
명 : BCR16PM-12LG
6.7.3
규
격 : 600V 16A
6.7.4 Insulated Tab / Rated at 2000Vrms
6.7.5 UL Approved File No : E80271
6.8 Photo Triac
6.8.1
제
조
사 : TOSHIBA(2
차 VENDER KODENSHI, SHARP, LITEON)
6.8.2
모
델
명 : TLP560J
6.8.3
규
격 : 600V 100mA
6.8.4 Isolation Voltage : 2500Vrms
6.8.5 UL Approved File No : E67349
6.9 Photo TR
6.9.1
제
조
사 : TOSHIBA(2
차 VENDER KODENSHI, LITEON)
6.9.2
모
델
명 : TLP181
6.9.3 Isolation Voltage : 3750Vrms(min)
6.9.4 UL Approved File No : E67349
※
상기
부품은
순간온수모듈의
응용방법(
적용
사양)
에
따라
변경될
수
있으므로
국내,
해외
인증시
인터텍과
협의하여
주시기
바랍니다.
11/18 (
주)
인
터
텍 A4(210×297)
7.
부속
정격
7.1
절연저항
상온(20±5),
상습에서
충전부와
비충전
금속부
사이를 DC500V
절연저항계로
측정시 100
이상일
것.
7.2
절연내압
상온(20±5),
상습에서
충전부와
비충전
금속부
사이에
내전압측정기 AC1800V 5mA 1sec
에
견딜
것.
7.3
누설전류
정격전압,
정격주파수를
가하고
비충전
금속부와
접지
사이에서
누설전류계를
사용하여
측정한
누설전류가 1mA
이하일
것.
7.4
순시정전
시험
정격전압,
정격주파수를
가한
상태에서
순시정전(
순간단락)
지속시간 50ms
이하에서
정상동작
할
것.
7.5
입수압력
시험
과부하
수압 3.0f/
의
수압을 1
분간
가해
누수,
변형등
기타
이상이
없을것.
7.6
내습
시험
40±3,
습도 90%
에서 24
시간
방치
후
수분을
닦아내고
충전부와
비충전
금속부
사이의
절연
저항을
측정했을
때 100
이상이며
절연내압 AC 1800V 5mA 1sec
간
견딜
것.
7.7
저온방치
시험
제품
안의
물을
모두
배수하고 -5
에서 24
시간
방치한
후
상온(20±5)
에서 4
시간이
지난
뒤에
사용했을
때,
누수나
기능상
이상이
없을
것.
7.8
고온방치
시험
제품
안의
물을
모두
배수하고 40±3,
습도 60%
에서 72
시간
방치한
후
상온(20±5)
에서 4
시간이
지난
뒤에
사용했을
때,
누수나
기능상
이상이
없을
것.(48±3 THERMOSTAT
적
용)
7.9
수명
시험
온수모듈
내부로 700cc/min
의
물이
흐르는
상태에서
동작 2
분,
휴지 10
초를 1
회로
하여 30,000
회
반복
시험
후 7-1, 7-2, 7-3
항을
만족하고
누수나
기능상
이상이
없을
것.
12/18 (
주)
인
터
텍 A4(210×297)
8.
동작성능
-
측정
시료 : IHM-2216N (220Vac/1600W) /
출수 Buffer
사용
-
측정
계측기 YOKOGAWA LR8100
열전대 T Range(0~100) 0.1Hz
8.1
가열&
온도유지
성능
50
40
30
20
10
----
입수온도----
출수온도
- Chart Speed(10mm/min)
-
입력전압 : 220Vac / 60Hz
-
입수온도 : 15
-
입수유량 : 740cc/min
-
설정온도
40→40→35→30→40
-
설정온도 ON/OFF
반복시 Overheat
없음
-
설정온도
도달
성능 ± 1
유지
-
설정온도
온도유지
성능 ± 0.5
유지
8.2
출수온도
세분화
성능
50
40
30
20
10
----
입수온도----
출수온도
- Chart Speed(10mm/min)
-
입력전압 : 220Vac / 60Hz
-
입수온도 : 15
-
입수유량 : 740cc/min
-
설정온도
30→33→36→38→40
→38→36→33→30
-
설정온도
도달
성능 ± 1
유지
-
설정온도
온도유지
성능 ± 0.5
유지
-
설정온도
변경시 Over/Underheat
없음
13/18 (
주)
인
터
텍 A4(210×297)
8.3
입수
유량별
성능
8.3.1
유량 540cc/min
가열&
온도유지
성능
50
40
30
20
10
----
입수온도----
출수온도
- Chart Speed(10mm/min)
-
입력전압 : 220Vac / 60Hz
-
입수온도 : 15
-
입수유량 : 540cc/min
-
설정온도
40→40→35→30→40
-
설정온도 ON/OFF
반복시 Overheat
없음
-
설정온도
도달
성능 ± 1
유지
-
설정온도
온도유지
성능 ± 0.5
유지
8.3.2
유량 900cc/min
가열&
온도유지
성능
50
40
30
20
10
----
입수온도----
출수온도
- Chart Speed(10mm/min)
-
입력전압 : 220Vac / 60Hz
-
입수온도 : 15
-
입수유량 : 900cc/min
-
설정온도
40→40→35→30→40
-
설정온도 ON/OFF
반복시 Overheat
없음
-
설정온도
도달
성능 ± 1
유지
-
설정온도
온도유지
성능 ± 0.5
유지
- 40
설정시 Full Power
동작
14/18 (
주)
인
터
텍 A4(210×297)
8.4
입력
전압별
성능
8.4.1
입력전압 -10Vac(210Vac)
에서의
가열&
온도유지
성능
50
40
30
20
10
----
입수온도----
출수온도
- Chart Speed(10mm/min)
-
입력전압 : 210Vac / 60Hz
-
입수온도 : 15
-
입수유량 : 740cc/min
-
설정온도
40→40→35→30→40
-
설정온도 ON/OFF
반복시 Overheat
없음
-
설정온도
도달
성능 ± 1
유지
-
설정온도
온도유지
성능 ± 0.5
유지
8.4.2
입력전압 +10Vac(230Vac)
에서의
가열&
온도유지
성능
50
40
30
20
10
----
입수온도----
출수온도
- Chart Speed(10mm/min)
-
입력전압 : 230Vac / 60Hz
-
입수온도 : 15
-
입수유량 : 740cc/min
-
설정온도
40→40→35→30→40
-
설정온도 ON/OFF
반복시 Overheat
없음
-
설정온도
도달
성능 ± 1
유지
-
설정온도
온도유지
성능 ± 0.5
유지
15/18 (
주)
인
터
텍 A4(210×297)
8.5
동작중
입수
유량
가변시
온도유지
성능
50
40
30
20
10
----
입수온도----
출수온도
- Chart Speed(10mm/min)
-
입력전압 : 220Vac / 60Hz
-
입수온도 : 15
-
입수유량 : 650~850 cc/min
가변(3sec)
550~850 cc/min
가변(3sec)
-
설정온도 : 40
-
설정온도
도달
성능 ± 1
유지
- 200cc
가변시
출수온도 ± 0.5
- 300cc
가변시
출수온도 ± 0.8
8.6
동작중
입력
전압
가변시
온도유지
성능
50
40
30
20
10
----
입수온도----
출수온도
- Chart Speed(10mm/min)
-
입력전압 : 220± 10Vac/60Hz
가변(3sec)
220± 20Vac/60Hz
가변(3sec)
-
입수온도 : 15
-
입수유량 : 740 cc/min
-
설정온도 : 36
-
설정온도
도달
성능 ± 1
유지
- 10Vac
가변시
출수온도 ± 0.5
- 20Vac
가변시
출수온도 ± 1.0
16/18 (
주)
인
터
텍 A4(210×297)
8.7
입수
온도별
성능
8.7.1
입수온도 10
에서의
출수온도
세분화
성능
50
40
30
20
10
----
입수온도----
출수온도
- Chart Speed(10mm/min)
-
입력전압 : 220Vac / 60Hz
-
입수온도 : 10
-
입수유량 : 740cc/min
-
설정온도
30→33→36→38→40
→38→36→33→30
-
설정온도
도달
성능 ± 1
유지
-
설정온도
온도유지
성능 ± 0.5
유지
-
설정온도
변경시 Over/Underheat
없음
8.7.2
입수온도 25
에서의
출수온도
세분화
성능
50
40
30
20
10
----
입수온도----
출수온도
- Chart Speed(10mm/min)
-
입력전압 : 220Vac / 60Hz
-
입수온도 : 25
-
입수유량 : 740cc/min
-
설정온도
30→33→36→38→40
→38→36→33→30
-
설정온도
도달
성능 ± 1
유지
-
설정온도
온도유지
성능 ± 0.5
유지
-
설정온도
변경시 Over/Underheat
없음
17/18 (
주)
인
터
텍 A4(210×297)
9. Part Number Decoder
IHM - 22 16 N 02 DR 1 ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➀ Instantaneous Heater Module ➁ AC Supply Voltage - 10 : 100 Vac 50/60Hz - 11 : 110 Vac 50/60Hz - 12 : 120 Vac 50/60Hz - 22 : 220 Vac 50/60Hz ➂ Operating Dissipation - 12 : 1200 W - 14 : 1400 W - 16 : 1600 W - 24 : 2400 W - 28 : 2800 W - 80 : 8000 W ➃ Option 1 - Blank :
원통형히터 - N :
판형히터 - T :
판형 3
중히터 ➄ Option 2 - 02 : Hardware Version ➅ Option 3 - XX :
납품처
약자 ➆ Option 4 - X1 :
납품처
요청
옵션사항 (ex) BIMETAL 187Y or Z TERMINAL / Earth Wire / Thermal Cut-Off
사양
10. Label
IHM-2216N 01 DR1 ①
220Vac/60Hz ② V1.1F38 ③
IT0901-0001 ④
① Instantaneous Heater Module Model ② AC Supply Voltage ③ Program Version F : Temperature Fix (F38 : 38
온도고정형) L : Limit Power (L08 : 800W
히터출력제한형) ④ Serial Number IT YYMM-XXXX (YY : Year / MM : Month / XXXX : Serial No.)