Page 1: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 1

Finding the root cause of ESD problems

Dr. David Pommerenke

With contributions from all members of the EMC laboratory

University Missouri Rolla – EMC [email protected]

Page 2: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 2

ESD is combines many tests in one test

ESD failure analysis

Susceptibility scanning

Voltage in traces during ESD testing

Content

Page 3: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 3

Definitions

Hard-error: Any error that leads to a physical failure of the IC. (Excessive leakage current, loss of functionality)

Soft-error: Any error that can be cured by resetting the system (logical errors: bit error, false reset)

Page 4: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 4

EnergieDirect discharge into a PIN of a connector

Dielletric breakdownSpark through a plastik front panel

CurrentVoltage drop accross a protection circuit

Current derivativeInsufficient response of a protection circuit

Secondary breakdownCurrent raises chassies potential until secondary breakdown occurs inside the chassie

Near fieldDischarge to the metallic chasies. Fields couple through a nearby opening.Fields couple into a cable.

FarfieldFields from a distant ESD induce currents on the chassis.

Physical parameters that may lead to an ESD failure

ESD combines many different tests into one test standard.

From electrostatics, via breakdown physics to a 1 GHz 20kV/m pulse.

Page 5: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 5

It failed, what now?

Is it a soft or a hard failure?

At which test point did it fail?

At which voltage did it fail?

Was it in contact or air discharge mode?

How repeatable is the failure?

It has failed! - What to do now?

Question: What do you do to debug ESD problems?

Page 6: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 6

How to fix it?

Exact circuit understanding

Pro: The most cost efficient solution. Learn how to design in the future.

Contra: Need to understand software Need to understand circuits Requires specialized equipment May require special firmware

Shielding

Pro: No system understanding needed. If it works, the fast!

Contra: Often more expensive solution Adds material

But how to do it?

Page 7: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 7

20mm50mm

200mm

@ 8kV,

restart

@ 10kV

restart

@ 15kV

restart

EUT

display

Local probing around the EUT

A first start of finding the root cause may be:

Locating sensitivity on the outside might help to correlate to the affected IC or trace, but:

• Outside location may only be a result of breach in shielding

• Outside location is too broad to correlate to details inside: Let’s go inside!

Page 8: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 8

Different coupling mechanisms require different probes

Injection can be done:

• To the enclosure

• To cables

• To connectors

• To boards

• To board traces

• To lead-frames traces

- dm

- cm

- mm

- cm2

- 5 mil (using microscope)

- 1 mil (using microscope)

Page 9: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 9

Probes used for injection

Page 10: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 10

Different coupling mechanisms require different probes

Direct injection between to “grounds”.

In selecting the right injection method one has to try to emulate the same excitation mechanism as occurs during the standardized test or at the customer site.

Anticipating the right method is often guided by carefully observing the differences of failure signature at different test points.

Page 11: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 11

0 20 40 60 80 100-200

0

200

400

600

800

1000

Time [ns]

Vol

tage

[V

]

The Output of the High Voltage Transmission Line Pulse Generator

Disturbance sources: TLP and narrow pulse

The measurement of the high voltage transmission line pulse generator output pulse, about 500 ps rise (20-80%)

0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2-0.04

-0.02

0

0.02

0.04

0.06

0.08

0.1

0.12

0.14

0.16

Time [ns]

Vol

tage

on

trac

e [V

]

Less than 200 ps pulse

Narrow pulse generator

Page 12: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 12

Automated Susceptibility Scanning system of UMR

Brief explanation

The system moves injection probes to predefined locations, injects pulses and observes the system response.

In most cases, pulses are “ESD-like”, e.g., having rise times 0.1 -2 ns.

Injection is done using different injection probes for testing direct coupling, E and H-field coupling.

If needed, the voltages at the input of the IC are measured during the ESD event.

Page 13: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 13

ControlComputerScope

signal probing

Pulse injection

Probe position data, motion control

TLP triggering signal

MotionControl

TLP

PowerS/W

System monitor(parallel port)

Automated Susceptibility Scanning system of UMR

Critical is the error feedback: A test code needs to be operating on the EUT. The test code signals to the control PC if a malfunction has occurred. If so, the level of injected noise (by source setting, not by induced voltage) is recorded and the EUT is reset.

Page 14: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 14

Test flow diagram

Page 15: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 15

Example: Identifying sensitive nets

• Besides direct coupling to an IC, four sensitive nets are identified

• Only 4 nets are sensitive, but there sensitivity is 10X as strong as any other net

180 190 200 210 220 230 240 250240

250

260

270

280

290

300

310

180 190 200 210 220 230 240 250

240

250

260

270

280

290

300

310

180 190 200 210 220 230 240 250

240

250

260

270

280

290

300

310

180 190 200 210 220 230 240 250

240

250

260

270

280

290

300

310

Net 1

Net 2

Net 3

Net 4

50 100 150 200 250

250

300

350

400

450

Net 1

Net 2

Net 3

Net 4

Page 16: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 16

180 190 200 210 220 230 240 250

240

250

260

270

280

290

300

310Probe Polarization : ←

Scanned in next stage

The same area is scanned using different polarization of the H-field probe.

The difference between the “left” and the “right” polarization is the polarity of the induced noise voltage.

The sensitive traces are identified by circuit diagram.

If needed a finer scan is performed.

Example: Identifying sensitive nets

Page 17: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 17

1mm

1.5mm178 180 182 184 186 188 190 192 194

238

240

242

244

246

248

250

252

254

256

• A critical part of the board in the previous scanned area has been fine-scanned using very small magnetic field probe to identify the correct trace

• The scan resolution was set to 0.5mm x 0.5mm• The small probe couples less energy into the trace, but in a highly localized area

Example: Identifying sensitive nets

Page 18: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 18

180 190 200 210 220 230 240 250

240

250

260

270

280

290

300

310

180 190 200 210 220 230 240 250

240

250

260

270

280

290

300

310

180 190 200 210 220 230 240 250

240

250

260

270

280

290

300

310

180 190 200 210 220 230 240 250

240

250

260

270

280

290

300

310

Net 1

Net 2

Net 2

Net 3

50 100 150 200 250

250

300

350

400

450

Net 1

Net 2

Net 2

Net 3

• After comparing the identified sensitive nets with PCB layout, three nets have been identified to be sensitive to ESD

• The sensitivity of those nets have been quantified in terms of applied voltage in the HV generator

• Induced current direction on the each sensitive net has been identified

Modification to a sensitive net

Page 19: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 19

TX RX

100ohm

330pF

Filter Location

Modification to a sensitive net

Simple Low Pass

Page 20: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 20

60 80 100 120 140 160 180 200 220 240 260

260

280

300

320

340

360

380

400

420

440

460

Before After

60 80 100 120 140 160 180 200 220 240 260

260

280

300

320

340

360

380

400

420

440

460

Filter location

Modification to a sensitive net

Page 21: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 21

70 75 80 85 90 95 100 105

275

280

285

290

295

300

305

310

Scanned Area

Medium Magnetic Probe

• The top side of the PCB is scanned using the medium size magnetic probe with four different polarization

• Some sensitive areas on the IC are identified

Direct coupling to ICs

Page 22: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 22

Direct coupling to ICs

5 10 15 20 25 30 35 40

5

10

15

20

25

30

35

40

Signal couples directly into the IC IC reacts to narrow pulses much narrower than the intended signals

2.5 3 3.5 4

-2.5

-2

-1.5

-1

-0.5

0

0.5

Time [ns]

V

300ps

For such an ICs, no PCB or shielding solution is economical.Scanning can identify such situations and help to verify improvementsin the IC design, packaging (e.g., flip-chip) or the control software.

In our experience, direct coupling to ICs is growing problem:• Fast IC process technology is used more and more in badly shielded products.• Coupling to PCBs is reduced by burried layers and traces• Dense PCBs have hardly any traces visible (BGA packages)

Page 23: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 23

New is better, well ….

Shown are the voltage settings of a pulse generator at which an upset occurs if A narrow pulse (less than 300 ps width at 50% amplitude) is causing an upset of the IC.Note: the new IC performed worse!

Worsening ESD soft-error performance is a significant risk if new processesare introduced, or if I/O structures are modified.

Page 24: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 24

Voltages on traces

-10 -5 0 5 10 15 20-2

0

2

4

6

8

time [ns]

Tra

ce v

olt

age

[V

]

-2 -1.5 -1 -0.5 0 0.5 1 1.5 2-2

0

2

4

6

8

time [ns]

Tra

ce v

olt

age

[V

]

Page 25: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 25

Semi rigid coax cable, connected to 20GS/sec 6 GHz bandwidth scope

470 Ohm

GND VIA(close to the Trace)

How measure in-circuit while pulsing?

The trace is loaded by 470 + 50 Ohm.

The small loop areaensures little dB/dtcoupling and good frequency response of the probing method.

Page 26: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 26

Three traces have been isolated by terminating/filtering circuits

Double pulse has been eliminated

The reset line still reacts to this narrow pulse (the system crashed)

It has been shown that the IC of interest is causing the crash, reacting

to a very narrow pulse

Inner layer trace

connects to another IC

connects to another IC

0 1 2 3 4 5

0.8

1

1.2

1.4

Time [ns]

Vo

ltag

e[V

]

75ohm

75ohm

100pF

56pF

75ohm

56pF

IC of interest

Coaxial Probeattached here

Pulse injectionhere

1000 Very Narrow pulse on slow status line (< 150ps) leads to crash

Voltages on a status line

Page 27: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 27

208 210 212 214 216 218 220 222 224

265

270

275

280

285

290

208 210 212 214 216 218 220 222 224

265

270

275

280

285

290

208 210 212 214 216 218 220 222 224

265

270

275

280

285

290

208 210 212 214 216 218 220 222 224

265

270

275

280

285

290

200 202 204 206 208 210 212 214 216 218

285

290

295

300

305

310

315

200 202 204 206 208 210 212 214 216 218

285

290

295

300

305

310

315

200 202 204 206 208 210 212 214 216 218

285

290

295

300

305

310

315

200 202 204 206 208 210 212 214 216 218

285

290

295

300

305

310

315

Clock_N Clock_P

Clock_P(Ch 2 on scope)

Clock_N(Ch 1 on scope)

200ps pulse injection here!

Pulse has been applied repeatedly, increasing the voltage until system crashes

Waveforms are recorded (20 GHz / 6 Gsample/sec).

Differential clock

Page 28: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 28

ESD Event on differential clock

Pulse injectionhere

Coaxial Probeattached here

Drive IC ReceiverIC

3 3

3 3

5 0

5 0

0 10 20

0

0.4

0.8 V

olta

ge

on

tra

ce [

V]

-5V, on DP, crashed - 2

0 10 20-1

0

1

Time [ns]

Vo

ltag

e[V

]

Voltage difference

crash

Very sensitive to noise during the transition

Page 29: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 29

ESD Event on differential clock

0 4 8 12 16 20

0

1

2

Vo

ltag

e o

n t

race

[V

] 20V, on DP, Not crashed - 1

0 4 8 12 16 20-1

0

1

Time [ns]

Vo

ltag

e[V

]

Voltage difference

Crash threshold: approx. 0.2V

0 4 8 12 16 20

0

1

Vo

ltag

e o

n t

race

[V

] -8V, on DP, Crashed - 2

0 4 8 12 16 20-1

0

1

Time [ns]

Vo

ltag

e[V

]

Voltage difference

No crash!

crash

Crash threshold: approx. 0.2V

+

-Clock_N

Clock_P

Differential inputhas an offset

Page 30: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 30

The result is repeatable. Increasing difference should not lead to a system crash.Why?

0 5 10 15 20 25-0.5

0

0.5

1

1.5

2

Time [ns]

Vol

tage

on

trac

e [V

]

13V, on DP, crashed - 2

0 5 10 15 20 25-1

-0.5

0

0.5

1

1.5

Time [ns]

Vol

tage

[V]

Voltage difference

Noise increased differential voltage

Page 31: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 31

ESD on differential clock – Common Mode disturbance

0 4 8 12 16 20

0

1

2

Vo

ltag

e o

n t

race

[V

]

0 4 8 12 16 20-1

0

1

Time [ns]

Vo

ltag

e[V

]

Voltage difference

No crash If the common mode voltage is relatively low, the differential input will suppress the common mode signal.

2x330

Page 32: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 32

0 2 4 6 8 10 12 14 16 18 20-3

-2

-1

0

1

2

Time [ns]

Vol

tage

on

trac

e [V

]

CK PE 100M ICH DN/DP(inject on DP/DN -100V)

0 2 4 6 8 10 12 14 16 18 20-2

-1

0

1

Time [ns]

Vol

tage

[V]

Voltage difference

no crash

no crash

No crash, although the differential signal is already strongly disturbed

Common mode: Not crashed

Page 33: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 33

120V from the HV generator was injected on both Clock_P andClock_N

Crashed

0 2 4 6 8 10 12 14 16 18 20-1

0

1

2

3

4

Time [ns]

Vol

tage

on

trac

e [V

]

CK PE 100M ICH DN/DP(inject on DP/DN 120V)

0 2 4 6 8 10 12 14 16 18 20-1

-0.5

0

0.5

1

Time [ns]

Vol

tage

[V]

Voltage difference

Common mode: Crashed

Differential Mode is about as robust as single ended signaling. Design details matter: (conversion, common mode termination etc.)

0 2 4 6 8 10 12 14 16 18 20-1

0

1

2

3

4

Time [ns]

V

oltage on trace [V

]

CK PE 100M ICH DN/DP(inject on DP/DN 120V)

0 2 4 6 8 10 12 14 16 18 20-1

-0.5

0

0.5

1

Time [ns]

V

oltage[V

]

Voltage difference

crash

Page 34: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 34

How an IC can react to pulses

• Voltage surpasses threshold for a sufficiently long time

• Linear network, bond wire inductance and input capacitance, ring or peak the pulse, leading to a softerror.

• Voltage triggers non-linear effect on the input buffer

• Voltage causes ESD protection to forward bias, causes substrate injection or internal power fluctuations, leading to crash

• Current leads to latch-up, or latch-up like situation.

Page 35: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 35

Immunity problems caused by global coupling vs.

local coupling to one trace.

Correlation system level – board level.

IC level immunity test methods and robustness guidelines

for IC design are not well developed yet.

IC level immunity standards.

Software for improving immunity.

Latch-up and ESD protection circuit recovery, how many

of the observed soft errors are caused by latch-up?

Open Questions

Page 36: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 36

Conclusion

Using local injection the disturbed traced can be identified.

The sensitivity of I/O ports can be quantified.

These data can be used to analyze the function of circuits designed to reduce ESD sensitivity.

In-circuit measurements can be done while doing local injection, as the amount of common mode signal is vastly reduced.

This is a developing field, many questions are still out there,just waiting to be solved.

Page 37: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 37

IC ESD System level ESD

Consequence

Standard

Voltage

DUT

Operating?

Application method

Tested properties

When does it occur?

Destructive

CDM / HBM / MM

Typically < 3000

IC, sub system

System is not powered

Direct to the IC PINs

IC protection circuits

Manufacturing, handling

Destructive and Upset

IEC 61000-4-2

Typically < 15 000

System

System is operating

Enclosure, PINs

System design

Qualification tests,Customer site

IC and system level ESD testing

Page 38: # 1 Finding the root cause of ESD problems Dr. David Pommerenke With contributions from all members of the EMC laboratory University Missouri Rolla – EMC.

# 38

ProbePolarization

Induced Currenton the net

• The board has been scanned with four different probe polarization (up, down, left, right) to take account of the induced current on the board

• The medium size magnetic field probe was used with 1.5mm x 1.5mm scan resolution

• ESD sensitive net can be identified roughly, but the resolution is not so fine enough to pin point a single trace.

Example: Identifying sensitive nets