Transcript
8/2/2019 Vertical Pumps 50hz
1/36
vertical pumps 50 Hz
technical data
dp pumps
8/2/2019 Vertical Pumps 50hz
2/36
Content
Model identification 1
Features 2
Applications 3
Material specification 4
Pump connections 5
Shaft seal 6
Motor specifications 7
Dimensions and curves
DPV 2 / DPVE 2 8
DPV 4 / DPVE 4 10
DPV 10 12
DPV 14 Low speed motor 14
DPV 18 16
DPVF 24 Low speed motor 18
DPVF 32 20
DPVF 45 22
DPVF 65 24
DPLHS 6High pressure 26
Notes 28
dppumps is ISO-9001
and ISO-14001 certified.
Excellence in stainless
For decades DP-Pumps has been specialised
in vertical pumps.
A Dutch company in competition with big multi-
nationals in the world market.
The success of DP-Pumps lies in the innova-
tion of her products coming from a combination
of smart thinking and common sense.
The optimal involvement of our employees plus
a natural urge for improvement creates an
environment in which Total Quality
Management is self-evident.
The latest result of DP-Pumps' R&D depart-
ment is the vertical pump DPVE, a pump
specially developed for booster sets, which
from now on will set the trend.
Excellence instainless steel technologyThe most exceptional merit of the DPV series
is that all wetted parts are made of stainless
steel AISI 304 (DPV series) or stainless steel
AISI 316 (DPVS series).
For normal water the DPV series (stainless
steel AISI 304) fulfils, for water containing more
aggressive elements the DPVS series (stain-
less steel AISI 316) will be appropriate.
The existing deep draw and welding
technology has been significantly improved.
Through this technology more durable and
lighter stainless steel pump parts can be pro-
duced. The use of stainless steel for all wetted
parts prevents corrosion.
DPVE
Stainless steel pumps
02
8/2/2019 Vertical Pumps 50hz
3/36
Innovate with vision Of course DP-Pumps is there toserve you with tailor made advice.
Please feel free to contact us.
teel technology
One solution for many applications
Traditionally the building industry is one of themost important application fields for vertical
pumps.
The service friendly, compact DPVE has been-
specially developed for booster sets, but also
for sprinklers, fire-fighting and airconditioning
installations. Some of the applications in which
DPV pumps can be used are: water treatment,
boiler feed, cleaning appliances, cooling and
marine applications.
DPV 14 and DPV 24:
low noise level,long working life.In numerous cases extra demands are speci-
fied in relation to the noise level of pumps.
Specially for applications in housing, DP-
Pumps developed a low-speed pump. The
DPV14 and DPV24 are equipped with a 1425
min-1 motor.Not only producing a particularly
low noise level, but also guaranteeing an extra
long working life. The other DPV types are
equipped with 2850 min-1 motors.
03
8/2/2019 Vertical Pumps 50hz
4/36
FEATURES
Top bracket
One-piece casting ensures maxi-
mum stability. Stainless steel inlay
for maximum corrosion resistance.The height of the top bracket is
related to the shaft seal and the
electrical motor connection.
Shaft sealingSpring loaded DIN seal with bellow
construction and the fit to purpose
material combinations, ensure long
lifetime. For models with heavy
motors a cartridge version is provid-
ed, which enables seal exchange
without removing the motor.
Suction discharge casing
The separate base plate has under-
gone a special corrosion resistence
treatment. Entire housing made ofstainless steel. Flange connection
rotates to match flange and bolt ori-
entation. Victaulic connection
available on selected series.
Built-in check valve
The DPVE suction discharge casing
has an integrated check valve.
Construction with less partsforquick & easy assembly
04
8/2/2019 Vertical Pumps 50hz
5/36
Sleeve sealingSleeve construction ensures total
compensation of thermal expansion.
Specially shaped o-ring grooves for
optimal sealing.
Stainless steel pump shaftFlat faces on shaft for strong
shaft/impeller construction.
Stainless steel diffuser
Special design reduces internal
losses, which improves the efficien-
cy of the pump.
Pump shaft bearings
A combination of tungsten-carbide
and ceramic is used for the pumpshaft bearing.
Tailormade solutions
05
8/2/2019 Vertical Pumps 50hz
6/36
Booster sets
Boiler feed
Water treatment
Irrigation
Sprinkler installations
Carwash
Fire fighting
Cooling water transport
Marine applications
Chemical industry
Processing industry
Food processing industry
APPLICATIONS
06
8/2/2019 Vertical Pumps 50hz
7/36
MODEL IDENTIFICATION
dp pumps www.dp-pumps.com
Pumptype DPVS F 45 - 50 - 1
Basic materials DPV DP Vertical pumps in AISI 304 (1.4301).
DPVEDP Vertical pumps in AISI 304 (1.4301).
Male thread with built-in non-return valve on discharge side.
DPVS DP Vertical pumps in superior grade AISI 316 (1.4401).
DPLHS DP Vertical pumps in superior grade AISI 316 (1.4401) 40 Bar.
Pump connections Oval counterflanges with female thread (DPLHS round flanges).
F Round flanges DIN, JIS or ANSI.
V Victaulic connection.
Model/flow 45 Pump model indicates nominal flow in [M3/h].
Stages/head - 50 Indicates number of impeller stages (50=5).
- 1 One stage with half head impeller (only available on DPVF 45).
120
15 m3/h
Selectionexample: 15 m3/h - 120 m. (selected: DPV 18)
07
8/2/2019 Vertical Pumps 50hz
8/36
MATERIAL SPECIFICATION
08
Pumpseries DPVE DPV DPVS DPLHS
Material specification
Pump shaft and bushes AISI 303 (1.4305) AISI 316 (1.4401)
Impeller, diffuser,
suction/dischargecasing, sleeve
AISI 304 (1.4301) AISI 316L (1.4404)
Base plate GG20 (GJL-200) GG25 (GJL-250) -
Top bracket GG25 (GJL-250) AISI 316 (1.4408)
(Collar) flange - GGG40 (GJS-400) AISI 316 (1.4408)
Elastomers EPDM Viton
Liquid lubricated
bearings- ceramic/tungsten-carbide
Deareating
and drain plugbrass AISI 316 (1.4401)
Duty range
Temperature range [oC] -15 to 60 -15 to 120
Max. ambienttemperature [oC]
50
8/2/2019 Vertical Pumps 50hz
9/36
PUMP CONNECTIONS
dp pumps www.dp-pumps.com
Pump series DPVE DPV(S) DPV(S)F DPV(S)V DPLHS
Pressure class PN10 PN16 PN25 PN40
Connections male thread oval flange round sliding flange victaulic connection round cast flange
Norm G NEN ISO 228 G NEN ISO 228 DIN EN 1092-2 PN25 - DIN EN 1092-2 PN40
Optional - Rc NEN EN 10226ANSI B 16.1 cl.250
JIS B2238 16K- ANSI B 16.5 cl. 600
Counter-
connectionsoptional
oval counterflangeincluded
(female thread)optional
DPVE 2 G 112 - - - -
DPVE 4 G 112 - - - -
DPV 2 - G 1 DN 25 32 mm -
DPV 4 - G 114 DN 32 32 mm -
DPV 10 - G 112 DN 40 50 mm -
DPV 14 - G 114 - 50 mm -
DPV 18 - G 2 DN 50 50 mm -
DPVF 24 - - DN 65 - -
DPVF 32 - - DN 65 - -
DPVF 45 - - DN 80 - -
DPVF 65 - - DN 100 - -
DPLHS 6 - - - - DN 40
09
8/2/2019 Vertical Pumps 50hz
10/36
SHAFT SEAL
Shaft seal
Pump seriesDPV(S)
DPVE
DPV(S)F 24, 32, 45
> 7,5 kW andDPV(S)F 65 range
DPLHS 6
Seal type bellow sealbellow /
cartridge seal
spring loaded high
pressure seal
According to (norm) DIN 24960
max. working
pressure
1000 [kPa]
Carbon -
-
-
-
- Tungsten carbide
Secondary sealings DPV EPDM -
Secondary sealings
DPVS and DPLHSViton
Options
Dynamic part Silicon carbide -
Stationary part Silicon carbide -
Secondary sealings Viton or EPDM -
max. working
pressure
2500 [kPa]max. working
pressure
4000 [kPa]
Silicon carbide
Silicon carbide
Carbon
-
-
Carbon
dynamic
stationary
dynamic
stationary
dynamic
stationary
10
8/2/2019 Vertical Pumps 50hz
11/36
MOTOR SPECIFICATIONS
Motor specifications:
Specially developed three-phase improved efficiency motors according to IEC standard.
Nominal power supply [V] : 380 and 420
Frequency [Hz] : 50
Nominal rotation speed [min-1] : 1425 or 2850
Protection class : IP55
Insulation class : F
Efficiency class : eff2
dp pumps www.dp-pumps.com11
P[kW]
[%]
n[min-1]
Lp
[dB(A)]
Max.
Starts
[h-1]
220V 230V 240V 380V 400V 420V 660V 692V 725V
I max[A]
P[kW
]
[%]
n[min-1]
Lp
[dB(A)]
Max.
Starts[h-1]
220V 230V 240V 380V 400V 420V 660V 692V 725V
I max[A]
2 Pole - 3 Phase 50Hz
4 Pole - 3 Phase 50Hz
0,37 2730 1,9 1,8 1,8 1,1 1,1 1,070,0 64 50
0,55 2765 2,8 2,7 2,6 1,6 1,6 1,575,0 64 50
0,75 2890 3,6 3,5 3,3 2,1 2,0 1,979,0 66 50
1,10 2920 5,2 5,0 4,8 3,1 2,9 2,884,0 66 50
1,50 2840 7,1 6,8 6,4 4,1 3,9 3,778,0 65 30
2,20 2845 9,9 9,4 8,9 5,7 5,4 5,281,5 65 30
3,00 2895 12,6 12,0 11,4 7,3 6,9 6,683,5 67 204,00 2915 16,3 15,5 14,7 9,4 8,9 8,585,0 69 20
5,50 2910 22,8 21,6 20,6 13,2 12,5 11,986,0 69 15
7,50 2900 28,6 27,1 25,9 16,5 15,7 15,087,0 69 12
11,00 2935 46,0 43,9 42,4 26,5 25,4 24,588,5 76 11
15,00 2930 59,0 55,7 53,6 34,0 32,2 31,090,0 76 10
18,50 2940 72,0 67,9 65,7 41,5 39,2 38,091,0 76 10
22,00 2935 84,5 81,3 77,8 49,0 46,9 45,091,0 76 10
30,00 2945 96,7 92,5 88,7 56,0 53,2 50,791,5 84 6
37,00 2951 116,9 111,9 107,2 67,7 64,3 61,392,2 86 6
4,2 4,0 3,85,4 5,2 4,9
7,6 7,2 6,9
9,6 9,1 8,6
15,3 14,7 14,2
19,7 18,6 17,9
24,0 22,6 22,0
28,3 27,1 26,0
35,8 34,3 32,6
39,0 38,0 38,0
0,55 1390 2,8 2,7 2,5 1,6 1,5 1,470,0 58 50
0,75 1385 3,6 3,4 3,3 2,1 2,0 1,974,0 58 50
1,10 1415 5,7 5,4 5,2 3,3 3,1 3,076,0 58 50
1,50 1420 7,3 7,0 6,7 4,3 4,1 3,978,5 58 50
2,20 1420 10,3 9,8 9,4 6,0 5,7 5,481,0 62 50
3,00 1415 13,3 13,3 12,1 7,7 7,7 7,082,7 62 15
4,00 1445 16,9 17,0 15,6 9,8 10,0 9,084,5 62 15
5,50 1450 22,8 21,7 21,7 13,2 12,5 12,586,0 62 10
7,50 1455 30,4 30,4 30,5 17,6 17,6 17,687,5 62 10
11,00 1450 41,9 41,9 41,9 24,2 24,2 24,288,5 64 10
15,00 1460 57,2 52,9 51,0 33,0 30,5 29,590,0 64 10
4,5 4,5 4,0
5,8 5,8 5,2
7,6 7,2 7,2
10,6 10,2 10,2
12,5 14,0 14,0
19,1 17,7 17,0
8/2/2019 Vertical Pumps 50hz
12/36
DPV 2
DPVE 2
12
DPVE
Pumptype
DPV(S)(F)(V)(E)
Motorpower
[kW]
DimensionsE1
[mm]
DimensionsE2
[mm]
Shippingvolume
[m3]
DimensionsF1
[mm]
DimensionsF1
[mm]
DimensionsF2
[mm]
Netweight
[kg]
Netweight
[kg]
DPVEDPV(S)(V)General
DimensionsF1
[mm]
DimensionsF2
[mm]
Netweight
[kg]
DPV(S)F
Grossweight
[kg]
Grossweight
[kg]
Grossweight
[kg]
DimensionsE1
[mm]
DimensionsE2
[mm]
2- 10 0,37 431433 232 138 110 1113 13170,042 458 257 14 16143 93
2- 20 0,37 431433 232 138 110 1113 13170,042 458 257 14 16143 93
2- 30 0,37 452454 253 138 110 1214 14170,042 479 278 14 16143 93
2- 40 0,55 473475 274 138 110 1315 15190,042 500 299 16 18143 93
2- 50 0,55 494496 295 138 110 1416 16190,042 521 320 16 18143 93
2- 60 0,75 554553 326 156 120 1917 21210,049 578 351 18 201 60 1 01
2- 70 0,75 574 347 18 210,049 599 372 18 211 60 1 01
2- 80 1,10 595 368 20 230,049 620 393 20 221 60 1 01
2- 90 1,10 616 389 20 240,049 641 414 21 231 60 1 01
2- 100 1,10 637 410 21 240,049 662 435 22 241 60 1 01
2- 110 1,10 658 431 21 250,055 683 456 24 241 60 1 01
2- 130 1,50 739 483 27 310,055 764 508 28 301 74 1 42
2- 150 1,50 781 525 28 320,069 806 550 29 311 74 1 42
2- 160 2,20 827 546 31 350,069 852 571 32 351 74 1 42
2- 180 2,20 869 588 32 360,069 894 613 33 361 74 1 42
2- 200 2,20 911 630 33 370,069 936 655 34 371 74 1 42
2- 230 3,00 1017 703 43 490,114 1042 728 44 491 98 1 55
2- 250 3,00 1059 745 44 500,114 1084 770 45 501 98 1 55
8/2/2019 Vertical Pumps 50hz
13/36
(E) 2-10-0,37kW
(E) 2-20-0,37kW
(E) 2-30-0,37kW
(E) 2-40-0,55kW
(E) 2-50-0,55kW
(E) 2-60-0,75kW
2-70-0,75kW
2-80-1,1kW
2-90-1,1kW
2-100-1,1kW
2-110-1,1kW
2-130-1,5kW
2-150-1,5kW
2-160-2,2kW
2-180-2,2kW
2-200-2,2kW
2-230-3,0kW
2-250-3,0kW
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 Q(l/s)
H (m)
Pst0.07
0.09
0.11
0.13
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 Q(l/s)
Pst (kW)
20
30
40
50 (%)
2
4
6
8
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 Q(l/s)
NPSH (m)
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0Q(m
3/h)
DPV 2
DPVE 2Performance curveaccording to:
DIN 2548 Class C
50 Hz 2850 min-1
H (m)
1 m = 1,42 Psi
3,28 feet
9,806 kPa
0,098 Bar
Q (l/s)
1 l/s = 15,85 US.Gpm
13,20 Imp.Gpm
60 l/min
dp pumps www.dp-pumps.com 13
8/2/2019 Vertical Pumps 50hz
14/36
DPV 4
DPVE 4
14
DPVE
Pump
type
DPV(S)(F)(V)(E)
Mo
torpower
[kW]
Dimens
ions
E1
[mm
]
Dimens
ions
E2
[mm
]
Shipp
ingvo
lume
[m3]
Dimens
ions
F1
[mm
]
Dimens
ions
F1
[mm
]
Dimens
ions
F2
[mm
]
Ne
twe
ight
[kg
]
Ne
twe
ight
[kg
]
DPVEDPV(S)(V)General
Dimens
ions
F1
[mm
]
Dimens
ions
F2
[mm
]
Ne
twe
ight
[kg
]
DPV(S)F
Grosswe
ight
[kg
]
Grosswe
ight
[kg
]
Grosswe
ight
[kg
]
Dimens
ions
E1
[mm
]
Dimens
ions
E2
[mm
]
4- 10 0,37 431433 232143 93 1113 13170,042 458 257 13 15 138 110
4- 20 0,37 431433 232143 93 1113 13170,042 458 257 13 15 138 110
4- 30 0,55 452454 253143 93 1315 15180,042 479 278 15 17 138 110
4- 40 0,75 512511 284160 101,5 1816 20200,042 536 309 16 18 156 120
4- 50 0,75 533532 305160 101,5 1917 21200,042 557 330 17 19 156 120
4- 60 1,10 554553 326160 101,5 2119 23220,049 578 351 19 21 156 120
4- 70 1,10 574 347160 101,5 19 230,049 599 372 19 21
4- 80 1,50 634 378174 142 25 280,049 659 403 25 27
4- 90 1,50 655 399174 142 25 290,055 680 424 25 28
4- 100 1,50 676 420174 142 26 290,055 701 445 26 28
4- 110 2,20 722 441174 142 29 330,055 747 466 29 32
4- 130 2,20 764 483174 142 30 340,069 789 508 30 33
4- 150 2,20 806 525174 142 31 350,069 831 550 31 34
4- 160 3,00 870 556198 155 40 450,095 895 581 42 46
4- 180 3,00 912 598198 155 41 460,095 937 623 42 47
4- 200 3,00 954 640198 155 42 480,114 979 665 43 48
4- 230 4,00 1026 703224 168 49 550,114 1051 728 51 56
4- 250 4,00 1068 745224 168 50 560,114 1093 770 52 57
8/2/2019 Vertical Pumps 50hz
15/36
(E) 4-10-0,37kW
(E) 4-20-0,37kW
(E) 4-30-0,55kW
(E) 4-40-0,75kW
(E) 4-50-0,75kW
(E) 4-60-1,1kW
4-70-1,1kW
4-80-1,5kW
4-90-1,5kW
4-100-1,5kW
4-110-2,2kW
4-130-2,2kW
4-150-2,2kW
4-160-3,0kW
4-180-3,0kW
4-200-3,0kW
4-230-4,0kW
4-250-4,0kW
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 Q(l/s)
H (m)
Pst0.12
0.14
0.16
0.18
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 Q(l/s)
Pst (kW)
10
30
50
70 (%)
0
2
46
8
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 Q(l/s)
NPSH (m)
0 1 2 3 4 5 6 7 8 Q(m3/h)
DPV 4
DPVE 4Performance curveaccording to:
DIN 2548 Class C
50 Hz 2850 min-1
H (m)
1 m = 1,42 Psi
3,28 feet
9,806 kPa
0,098 Bar
Q (l/s)
1 l/s = 15,85 US.Gpm
13,20 Imp.Gpm
60 l/min
dp pumps www.dp-pumps.com15
8/2/2019 Vertical Pumps 50hz
16/36
DPV 10
16
8/2/2019 Vertical Pumps 50hz
17/36
10-10-0,75kW
10-20-0,75kW
10-30-1,1kW
10-40-1,5kW
10-50-2,2kW
10-60-2,2kW
10-70-3,0kW
10-80-3,0kW
10-90-4,0kW
10-100-4,0kW
10-120-5,5kW
10-140-5,5kW
10-160-5,5kW
10-180-7,5kW
10-200-7,5kW
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
0.0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 3.3 Q(l/s)
H (m)
Pst0.2
0.3
0.4
0.5
0.0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 3.3 Q(l/s)
Pst (kW)
10
30
50
70 (%)
0
1
2
3
0.0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 3.3 Q(l/s)
NPSH (m)
0 1 2 3 4 5 6 7 8 9 10 11 12 Q(m3/h)
DPV 10
Performance curve
according to:
DIN 2548 Class C
50 Hz 2850 min-1
dp pumps www.dp-pumps.com
H (m)
1 m = 1,42 Psi
3,28 feet
9,806 kPa
0,098 Bar
Q (l/s)
1 l/s = 15,85 US.Gpm
13,20 Imp.Gpm
60 l/min
17
8/2/2019 Vertical Pumps 50hz
18/36
DPV 14
18
8/2/2019 Vertical Pumps 50hz
19/36
8/2/2019 Vertical Pumps 50hz
20/36
DPV 18
20
8/2/2019 Vertical Pumps 50hz
21/36
DPV 18
Performance curve
according to:
DIN 2548 Class C
50 Hz 2850 min-1
H (m)
1 m = 1,42 Psi
3,28 feet
9,806 kPa
0,098 Bar
Q (l/s)
1 l/s = 15,85 US.Gpm
13,20 Imp.Gpm
60 l/min
dp pumps www.dp-pumps.com21
8/2/2019 Vertical Pumps 50hz
22/36
DPVF 24
22
8/2/2019 Vertical Pumps 50hz
23/36
DPVF 24
Performance curve
according to:
DIN 2548 Class C
50 Hz 1425 min-1
H (m)
1 m = 1,42 Psi
3,28 feet
9,806 kPa
0,098 Bar
Q (l/s)
1 l/s = 15,85 US.Gpm
13,20 Imp.Gpm
60 l/min
dp pumps www.dp-pumps.com23
8/2/2019 Vertical Pumps 50hz
24/36
DPVF 32
24
8/2/2019 Vertical Pumps 50hz
25/36
DPVF 32
Performance curve
according to:
DIN 2548 Class C
50 Hz 2850 min-1
dp pumps www.dp-pumps.com25
32-10-2,2kW
32-20-4,0kW
32-30-5,5kW
32-40-7,5kW
32-50-11,0kW
32-60-11,0kW
32-70-15,0kW
32-80-15,0kW
32-90-15,0kW
32-100-18,5kW
32-110-18,5kW
32-120-22,0kW
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
0 1 2 3 4 5 6 7 8 9 10 11 Q(l/s)
H (m)
Pst0.0
1.5
3.0
4.5
0 1 2 3 4 5 6 7 8 9 10 11 Q(l/s)
Pst (kW)
20
40
60
80 (%)
0
2
4
6
0 1 2 3 4 5 6 7 8 9 10 11 Q(l/s)
NPSH (m)
0 4 8 12 16 20 24 28 32 36 Q(m3/h)
H (m)
1 m = 1,42 Psi
3,28 feet
9,806 kPa
0,098 Bar
Q (l/s)
1 l/s = 15,85 US.Gpm
13,20 Imp.Gpm
60 l/min
8/2/2019 Vertical Pumps 50hz
26/36
DPVF 45
26
8/2/2019 Vertical Pumps 50hz
27/36
45-10-1-2,2kW
45-10-4,0kW
45-20-1-5,5kW
45-20-7,5kW
45-30-1-11,0kW
45-30-11,0kW
45-40-1-11,0kW
45-40-15,0kW
45-50-1-15,0kW
45-50-18,5kW
45-60-1-18,5kW
45-60-22,0kW
45-70-1-22,0kW
45-70-30,0kW
45-80-1-30,0kW
45-80-30,0kW
45-90-1-30,0kW
45-90-37,0kW
45-100-1-37,0kW
45-100-37,0kW
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
260
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Q(l/s)
H (m)
Pst 1/1
Pst 1/20
2
4
6
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Q(l/s)
Pst (kW)
20
40
60
80 (%)
0
3
6
9
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Q(l/s)
NPSH (m)
0 6 12 18 24 30 36 42 48 54 Q(m3/h)
DPVF 45
Performance curve
according to:
DIN 2548 Class C
50 Hz 2850 min-1
H (m)
1 m = 1,42 Psi
3,28 feet
9,806 kPa
0,098 Bar
Q (l/s)
1 l/s = 15,85 US.Gpm
13,20 Imp.Gpm
60 l/min
dp pumps www.dp-pumps.com27
8/2/2019 Vertical Pumps 50hz
28/36
DPVF 65
28
8/2/2019 Vertical Pumps 50hz
29/36
65-10-3,0kW
65-20-5,5kW
65-30-7,5kW
65-40-11,0kW
65-50-15,0kW
65-60-15,0kW
65-70-18,5kW
65-80-22,0kW
65-90-22,0kW
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
0.0 1.5 3.0 4.5 6.0 7.5 9.0 10.5 12.0 13.5 15.0 16.5 18.0 19.5 21.0 Q(l/s)
H (m)
Pst1.5
3.0
4.5
6.0
0.0 1.5 3.0 4.5 6.0 7.5 9.0 10.5 12.0 13.5 15.0 16.5 18.0 19.5 21.0 Q(l/s)
Pst (kW)
20
40
60
80 (%)
0.0
2.5
5.0
7.5
0.0 1.5 3.0 4.5 6.0 7.5 9.0 10.5 12.0 13.5 15.0 16.5 18.0 19.5 21.0 Q(l/s)
NPSH (m)
0 10 20 30 40 50 60 70 Q(m3/h)
DPVF 65
Performance curve
according to:
DIN 2548 Class C
50 Hz 2850 min-1
H (m)
1 m = 1,42 Psi
3,28 feet
9,806 kPa
0,098 Bar
Q (l/s)
1 l/s = 15,85 US.Gpm
13,20 Imp.Gpm
60 l/min
dp pumps www.dp-pumps.com29
8/2/2019 Vertical Pumps 50hz
30/36
DPLHS 6
30
8/2/2019 Vertical Pumps 50hz
31/36
DPLHS 6
Performance curve
according to:
DIN 2548 Class C
50 Hz 2850 min-1
H (m)
1 m = 1,42 Psi
3,28 feet
9,806 kPa
0,098 Bar
Q (l/s)
1 l/s = 15,85 US.Gpm
13,20 Imp.Gpm
60 l/min
dp pumps www.dp-pumps.com31
8/2/2019 Vertical Pumps 50hz
32/36
NOTES
32
8/2/2019 Vertical Pumps 50hz
33/36
NOTES
dp pumps www.dp-pumps.com33
8/2/2019 Vertical Pumps 50hz
34/36
NOTES
dp-pumps reserves the right to
make modifications
without prior notice.
All specifications could besubject to change.
dp-pumps reserves the right to
make modifications
without prior notice.
All specifications could be
subject to change.
34
8/2/2019 Vertical Pumps 50hz
35/36
NOTES
dp pumps www.dp-pumps.com35
8/2/2019 Vertical Pumps 50hz
36/36
dp pumps
dp pumps
P.O. Box 282400 AAAlphen aan den Rijn
Holland
t +31 172 48 83 25
f+31 172 46 89 30
dp@dp-pumps.com
www.dp-pumps.com