Vertical Emittance Tuning at the Australian Synchrotron Light Source Rohan Dowd Presented by Eugene Tan.

Post on 21-Jan-2016

218 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

Transcript

Vertical Emittance Tuning at the Australian Synchrotron Light Source

Rohan Dowd

Presented by Eugene Tan

Overview

• Machine overview

• LOCO method and minimisation technique

• Minimisation results and Measurements

• Sextupole alignment measurements

• Conclusion

ICFA - Low Emittance Ring Workshop 3-5 October 2011

Australian Synchrotron Light Source Overview

• Storage Ring Parameters

Energy 3 GeV

Circumference 216 m

RF Frequency 499.654 MHz

Peak RF Voltage 3.0 MV

Current 200 mA

Betatron Tune (h/v) 13.3/5.2

Momentum Compaction 0.002

εx (nominal) 10.4 nm∙rad

•Double bend lattice•14 fold symmetric •Gradient dipoles•Corrector and skew quad coils on sextupoles.•Independent power supplies for all multipoles.

ICFA - Low Emittance Ring Workshop 3-5 October 2011

LOCO method

• LOCO – Linear Optics from Closed Orbits.

• Adjusts the linear optics in the model to fit the real machine data

• Model response matrix – Machine response matrix = Error

• Minimise error by adjusting the model ‘fit parameters’

• Fit Parameters normally include:– BPM/Corrector gains and coupling– Corrector gains and coupling– Quadrupole strengths– Skew Quadrupole strengths

• We fit skew quadrupole components in all multipole magnets in our model lattice to represent rolls and misalignments.

ICFA - Low Emittance Ring Workshop 3-5 October 2011

LOCO Outputs

Outputs:• BPM Gains + Couplings• Skew components• Quad Strengths• Corrector gains/tilts

From these outputs we can calibrate the model and calculate skew corrections needed to adjust coupling

Consistent BPM/corrector coupling results for differing machine coupling settings – LOCO is not attributing the machine coupling to BPM/corrector coupling

Fits to varying machine coupling states (0.01-17% coupling)

Fits to identical machine coupling (10 samples)

ICFA - Low Emittance Ring Workshop 3-5 October 2011

Verified from attenuation measurements for the BPM.

Emittance Coupling minimisation• Emittance coupling (εy/εx) calculated from LOCO Calibrated model.

• Minimisation algorithm used to adjust skew quads to desired emittance coupling.

• Emittance coupling can be adjusted to arbitrary amounts with this method.Set Coupling LOCO Measured

CouplingCalculated εy (pm)

0.0% 0.01% 1.0

0.1% 0.12% 12.2

0.2% 0.23% 23.5

0.3% 0.33% 33.7

0.4% 0.43% 43.9

0.5% 0.54% 55.1

0.6% 0.64% 65.3

0.7% 0.74% 75.5

0.8% 0.84% 85.7

0.9% 0.92% 93.8

1.0% 1.04% 106.1

Phys. Rev. ST Accel Beams, 14, 012804 (2011)

Touschek Lifetime vs RF

• By taking single bunch lifetime over extended period the Touschek component of the lifetime can be extracted.

duu

edu

u

ueeD

DcNr

uu

x

x

yxz

e

)2)ln(3(2

1)ln(

22

3)(

,,)(

8

1 max3max

2

2

)1(

)( 1

0

1

0

2

a

a

eaib

beiti

b

i

a

i

dt

di

ICFA - Low Emittance Ring Workshop 3-5 October 2011

Touschek Lifetime vs RF

• Touschek component will also change with RF voltage.

• 2.1% energy acceptance (measured)

• Curve fit by varying εy/εx , other values fixed.

• Blue curve fit corresponds to εy = 1.24 pm

Set εy/εx (%)

Fitted εy/εx

(%)εy (pm)

0.01 0.012 ± 0.003 1.2 ± 0.3

0.06 0.043 ± 0.013 4.5 ± 1.3

0.10 0.093 ± 0.025 9.4 ± 2.6

ICFA - Low Emittance Ring Workshop 3-5 October 2011

Tune Crossing Results

LOCO Model εy (pm) ηy Component (pm) Betatron Coupling Component (pm)

Total Measured εy (pm)

Model – Measured (pm)

92.31 ± 2.77 2.24 ± 0.09 86.90 ± 2.65 89.55 ± 2.65 2.76 ± 3.83

76.30 ± 2.23 2.96 ± 0.12 76.50 ± 2.14 78.64 ± 2.14 2.34 ± 3.09

41.41 ± 1.24 1.73 ± 0.07 40.39 ± 1.84 42.23 ± 1.84 0.82 ± 2.22

22.75 ± 0.68 2.04 ± 0.08 19.69 ± 1.33 21.72 ± 1.33 1.03 ± 1.49

12.75 ± 0.38 2.14 ± 0.09 10.71± 1.02 12.85 ± 1.02 0.10 ± 1.09

7.55 ± 0.23 1.73 ± 0.07 5.41 ± 0.71 7.14 ± 0.71 0.41 ± 0.75

1.05 ± 0.03 0.73 ± 0.09 0.59 ± 0.30 1.32 ± 0.31 0.27 ± 0.31

ICFA - Low Emittance Ring Workshop 3-5 October 2011

How to improve?

• With current correction scheme we are stuck at 1-2 pm.

• Instead of correcting for misalignments, lets eliminate them.

• Recent ring alignments have made the coupling worse!

• Need to measure them independently – Beam based method

ICFA - Low Emittance Ring Workshop 3-5 October 2011

Sextupole offsets

•Shunt each sextupole magnet family to different strengths and take a response matrix at each point

•Perform LOCO analysis and fit skew quadrupole terms to each sextupole.

•Gradient of skew field vs sextupole field gives vertical offset.

ICFA - Low Emittance Ring Workshop 3-5 October 2011

Sextupole Offset Results

•Average offset: 70 microns

•Systematic alignment effect?

ICFA - Low Emittance Ring Workshop 3-5 October 2011

Cross Checks

Applied BPM Offset Measure Mean Beam Offset

Difference from zero

+125 234.6 ± 10.6 128.7 ± 18.8+75 167.7 ± 16.5 61.8 ± 22.6

0 105.9 ± 15.5 0-75 33.1 ± 17.8 -72.8 ± 23.6

-125 -16.1 ± 21.6 -122 ± 26.6

Magnet Original Offset (μm)

Applied Shim (μm)

New Offset (μm)

Delta offset (μm)

Sector 9 SFB -108.4 ± 44.6 150 -249.3 ± 7.2 140.9 ± 45.2Sector 11 SFB -56.7 ± 10.0 100 -120.4 ± 56.0 -63.4 ± 57.4Sector 9 SDA -14.6 ± 9.9 100 -118.3 ± 8.3 -103.7 ± 14.1

Cross checks show that amplitude of offset is correct and individual magnets can be adjusted accurately.

ICFA - Low Emittance Ring Workshop 3-5 October 2011

Sextupole Realignment – latest results

Re-aligned section (girder #16-21) now has much lower offsets. Simulated minimal vertical emittance has reduced from 1pm to 0.7 pm.

ICFA - Low Emittance Ring Workshop 3-5 October 2011

Conclusions

• εy of 1.3 pm.rad achieved through LOCO based minimisation.

• We have developed tools to accurately measure sextupole misalignments and eliminate them.

• Aim to have all sextupoles realigned by end of year and expect to reach < 1 pm emittance

• Also working on an inexpensive way to increase available skew correctors

ICFA - Low Emittance Ring Workshop 3-5 October 2011

Thank you

ICFA - Low Emittance Ring Workshop 3-5 October 2011