THERMO-HYGROMETER TERMO-HIGRÓMETRO
E N G L I S H User Manual
E S PA Ñ O L Manual de Instrucciones
CA846
Statement of Compliance
Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments certifies that this instrument has been calibrated using standards and instruments traceable to international standards.
We guarantee that at the time of shipping your instrument has met its published specifications.
An NIST traceable certificate may be requested at the time of purchase, or obtained by returning the instrument to our repair and calibration facility, for a nominal charge.
The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the customer. For recalibration, please use our calibration services. Refer to our repair and calibration section at www.aemc.com.
Serial #: ________________________________
Catalog #: 2121.24
Model #: CA846
Please fill in the appropriate date as indicated:
Date Received: _________________________________
Date Calibration Due: _______________________
Chauvin Arnoux®, Inc.d.b.a AEMC® Instrumentswww.aemc.com
Thermo-Hygrometer Model CA846 1
Table of Contents
ENGLISH .................................................................................................1ESPAÑOL ..............................................................................................13
1. INTRODUCTION ............................................................................... 21.1 International Electrical Symbols ................................................21.2 DefinitionofMeasurementCategories .....................................31.3 ReceivingYourShipment ..........................................................31.4 OrderingInformation .................................................................3
2. PRODUCT FEATURES ...................................................................... 42.1 Description ................................................................................42.2 PushButtons ............................................................................5
2.2.1 Center(Yellow)FunctionSwitch ...................................5
2.2.2 Back-Light and°C/°FButton ...................................52.2.3 MAXButton ...................................................................52.2.4 HOLDButton ................................................................5
3. SPECIFICATIONS............................................................................. 63.1 EnvironmentalSpecifications ....................................................63.2 MechanicalSpecifications ........................................................73.3 SafetySpecifications ................................................................7
4. OPERATION .................................................................................... 84.1 Recommendations ....................................................................84.2 OperatingtheModelCA846 .....................................................8
5. MAINTENANCE ............................................................................... 95.1 ReplacingtheBattery ...............................................................95.2 Cleaning ....................................................................................9
RepairandCalibration ...........................................................................10
Technical and Sales Assistance ............................................................10
Limited Warranty ...................................................................................11
WarrantyRepairs ...................................................................................11
2 Thermo-Hygrometer Model CA846
CHAPTER 1
INTRODUCTION
Warning • Do not connect to, or touch, any electrical circuit with the
Thermo-Hygrometer.
• Toavoidinjuryorfirehazard,donotoperatethisproductinanexplosiveatmosphereorenvironment.
• Remove (unscrew) the protective metal tube covering thesensorheadwhenusingtheThermo-Hygrometer.
• DonotimmersetheThermo-Hygrometersensorheadintoliq-uids-thismaycausepermanentdamagetothesensors.
• Screwontheprotectivemetal tubecoveringthesensorheadwhennotusingtheThermo-Hygrometer.
1.1 International Electrical SymbolsThis symbol signifies that the instrument is protected by double or reinforced insulation.This symbol on the instrument indicates a WARNING and that the operator must refer to the user manual for instructions before operating the instrument. In this manual, the symbol preceding instructions indicates that if the instructions are not followed, bodily injury, installation/sample and product damage may result.Risk of electric shock. The voltage at the parts marked with this symbol may be dangerous.This symbol refers to a type A current sensor. This symbol signifies that application around and removal from HAZARDOUS LIVE conductors is permitted.
In conformity with WEEE 2002/96/EC
Thermo-Hygrometer Model CA846 3
1.2 Definition of Measurement CategoriesCat. I: Formeasurementsoncircuitsnotdirectlyconnected to theAC
supplywall outlet such as protected secondaries, signal level,andlimitedenergycircuits.
Cat. II: Formeasurements performed on circuits directly connected totheelectricaldistributionsystem.Examplesaremeasurementsonhouseholdappliancesorportabletools.
Cat. III: For measurements performed in the building installation atthe distribution level such as on hardwired equipment in fixedinstallationandcircuitbreakers.
Cat. IV: For measurements performed at the primary electrical supply(<1000V) such as on primary overcurrent protection devices,ripplecontrolunits,ormeters.
1.3 Receiving Your ShipmentUponreceivingyourshipment,makesure that thecontentsareconsis-tentwith thepacking list.Notifyyourdistributorofanymissing items. Iftheequipmentappearstobedamaged,fileaclaimimmediatelywiththecarrierandnotifyyourdistributoratonce,givingadetaileddescriptionofanydamage.Savethedamagedpackingcontainertosubstantiateyourclaim.
1.4 Ordering InformationThermo-Hygrometer Model CA846 ..................................Cat. #2121.24Includes meter, shockproof holster, 9V battery and user manual.
4 Thermo-Hygrometer Model CA846
CHAPTER 2
PRODUCT FEATURES
2.1 DescriptionTheThermo-HygrometerModelCA846isaportable,compactdigitalmeterdesignedforsimplicityandone-handoperation.ThemeterusesanNTCasthetemperaturesensorprovidingexcellentresponsetimetochangesintemperature,goodrepeatabilityandaccuratereadings.
TheModelCA846alsoutilizesathin-filmpolymer-capacitivetyperelativehumidity sensorashygrometersensor,offeringexcellent recovery from100%moistureandfastresponsetimeanddurability.
1.Temperature/humiditysensor withprotectivesensorcover
2.3½digitdisplay
3.MAXbutton
4.°C/°Fselector&backlight
5.HOLDbutton
6. Power/mode selector
1
2
3 5
64
Thermo-Hygrometer Model CA846 5
2.2 Push Buttons
2.2.1 Center (Yellow) Function Switch
TurnsONtheThermo-Hygrometerandselectsthe%RHor°C/°Fsetting.SlidethebuttontoOFFafteruse.
2.2.2 Back-Light and °C/°F Button
• Pressthe buttontoturntheBack-LightON.
• Pressthe buttonagaintoturntheBack-LightOFF.
• Pressthe buttonfor2secondstochangethetemperaturescaleto°Cor°F.Thetemperaturescale°Cor°Fisdisplayedinthelowerrighthandcornerofthedisplay.
2.2.3 MAX Button• PresstheMAXbuttontoentertheMAXmode.The“MAX”annunciator
appearsintheupperrighthandcornerofthedisplay.• Theselectedrange(%RHor°C/°F)recordsandupdatesthemaximum
absolutevalues.• PresstheMAXbuttonagaintoexittheMAX-recordingmode(“MAX”
goesout).• TheHOLDbuttonmaybeusedintheMAXmodeto“Freeze”(nolonger
updates)theMAXmeasurementonthedisplay.
2.2.4 HOLD ButtonTheHoldbutton“freezes”thereadingonthedisplay.Pressthe“HOLD”buttontotoggle(activate/release)HOLD.IntheHOLDmode,the“HOLD”annunciatorisdisplayedintheupperpartoftheLCDdisplayandthelastreadingisdisplayeduntilreleased.
6 Thermo-Hygrometer Model CA846
CHAPTER 3
SPECIFICATIONS
3.1 Environmental SpecificationsTemperature Scale:Celsius(°C)orFahrenheit(°F)user-selectable
Temperature Sensor: NTC
Measurement Range:-4°to140°F,-20°to60°C
Resolution: 0.1°F/°C
Accuracy: -4° to 32°F ± 2°F (-20° to 0°C ± 1°C) 32° to 140°F ± 1°F (0° to 60°C ± 0.5°C)
Temperature Coefficient:0.1timestheapplicableaccuracyspecificationper°Cfrom0°to18°Cand28°to50°C(32°to64°Fand82°to122°F)
Humidity Sensor:Electroniccapacitancepolymerfilmsensor.(Thesensorisunaffectedbywatercondensation,andisimmunetomostreagentvapors)
Measurement Range: 0% to 100% RH
Resolution: 0.1% RH
Accuracy (@ 25°C): 10%-90% RH ± 5.0% 0%-10% RH; 90% to 100% RH ± 10.0%
Sensor Response Time for 90% of Range:60stypical
Sensor Stability:±2%RH,2yearstypical
Sensor Hysterisis (10% to 90% to 10% RH):±1%RHtypical
Sensor Temperature Dependence:Negligiblefrom32°to140°F(0°to60°C)
Operating Temperature:32° to 122°F (0°C to 50°C) at < 80% RH
Storage Temperature:-4°to140°F(-20°to60°C),0to80%RHwithbatteryremoved
Thermo-Hygrometer Model CA846 7
Accuracy:Statedaccuracyat23°C±5°C,<90%RH
Altitude: 2000m max
3.2 Mechanical SpecificationsDisplay:3½digitliquidcrystaldisplay(LCD)withmaximumreadingof1999
Over-Range:“OL”isdisplayed
Low Battery Indication: The isdisplayedwhenthebatteryvoltagedropsbelowtherequiredlevel
Sample Rate: 2.5timespersecond,nominal
Input Protection:24VDCor24Vrmsmaximuminputvoltageonanyinput
Power Supply:Standard9Vbattery(NEDA1604,IEC6F22006P,orequivalent)
Battery Life:200hourstypicalwithcarbonzincbattery
Dimensions:6.81 x 2.38 x 1.5" (173 x 60.5 x 38mm)
Weight:Approx7oz(197g)includingbattery
3.3 Safety Specifications
EN61010-1(1995-A2),ProtectionClassIII
OvervoltageCategory(CATIII,24V),PollutionDegree2
Indoor Use
*All specifications are subject to change without notice
8 Thermo-Hygrometer Model CA846
CHAPTER 4
OPERATION
4.1 Recommendations• Forreliablemeasurements,letthereadingsstabilize.Thehygrometer
andtemperaturesensormustreachequilibriumwiththemediummea-sured.
• Avoid temperature measurement errors induced by too short mea-surementtime,sunshineduringthemeasurement,heating,coldouterwalls,airdraft(e.g.fans),radiatingsourcesincludinghandand/orbodyheat,etc.
• Avoidhumiditymeasurementerrorsinducedbysteam,watersplashes,drippingwaterorcondensationonthesensor,etc.
• Avoidsensorcontaminationinducedbyparticlesintheairormeasure-mentsinpowderlikesubstances.Contaminationmaybeavoidedbymeasuringthroughafilter(usersupplied).Thefiltermustbecleanedorreplacedperiodically,dependinguponthedegreeofcontaminationatthemeasurementsite.
4.2 Operating the Model CA8461. Unscrewtheprotectivemetaltubecoveringthesensor.
2. Setthepowerswitchtothedesired%RHor°C/°Frange.
3. Letthereading(s)stabilize(%RHtakesatleast60secondstoreach90%).
4. Readthedisplay.
5. Afteruse,screwtheprotectivemetaltubebackontothesensor.
6. TurntheinstrumentOFFwhenfinished.
Thermo-Hygrometer Model CA846 9
CHAPTER 5
MAINTENANCE
Use only factory specified replacement parts.AEMC® will not be held responsible for anyaccident, incident, ormalfunction followinga repairdoneotherthanbyitsservicecenterorbyanapprovedrepaircenter.
5.1 Replacing the Battery The symbolappearsontheLCDdisplaywhenreplacementisneeded.Replacewithastandard9Vbattery(NEDA1604,IEC6F22).
Toreplacethebattery:• TurntheThermo-HygrometerOFF.• Removetherubberholster.• Removethescrewfromthebackofthemeterandliftoffthebattery
cover.• Replacethebattery,thenputtherearcoverandholsterbackon.
5.2 Cleaning• Useasoftclothlightlydampenedwithsoapywater.
• Rinsewithadampclothandthendrywithadrycloth.
• Donotuseanyabrasivesorsolvents.
• Donotletanyliquidenterthecaseorsensorarea.
10 Thermo-Hygrometer Model CA846
Repair and CalibrationToensurethatyourinstrumentmeetsfactoryspecifications,werecommendthatitbescheduledbacktoourfactoryServiceCenteratone-yearintervalsforrecalibration,orasrequiredbyotherstandardsorinternalprocedures.
For instrument repair and calibration:Youmust contactourServiceCenter foraCustomerServiceAuthorizationNumber(CSA#).Thiswillensurethatwhenyourinstrumentarrives,itwillbetrackedandprocessedpromptly.PleasewritetheCSA#ontheoutsideoftheshipping container. If the instrument is returned for calibration,weneed toknowifyouwantastandardcalibration,oracalibrationtraceabletoN.I.S.T.(Includescalibrationcertificateplusrecordedcalibrationdata).
Ship To: ChauvinArnoux®,Inc. d.b.a. AEMC®Instruments 15 Faraday Drive Dover,NH03820USA Tel: (800) 945-2362 (Ext. 360) (603) 749-6434 (Ext. 360) Fax: (603) 742-2346 or (603) 749-6309 repair@aemc.com
(Orcontactyourauthorizeddistributor)Costsforrepair,standardcalibration,andcalibrationtraceabletoN.I.S.T.areavailable.NOTE: You must obtain a CSA# before returning any instrument.
Technical and Sales AssistanceIfyouareexperiencinganytechnicalproblems,orrequireanyassistancewiththeproperoperationorapplicationofyourinstrument,pleasecall,mail,faxore-mailourtechnicalsupportteam:
ChauvinArnoux®,Inc. d.b.a. AEMC®Instruments 200FoxboroughBoulevard Foxborough,MA02035USA Phone: (800) 343-1391 (508) 698-2115 Fax: (508) 698-2118 techsupport@aemc.com www.aemc.com
NOTE: Do not ship Instruments to our Foxborough, MA address.
Thermo-Hygrometer Model CA846 11
Limited WarrantyTheModelCA846iswarrantedtotheownerforaperiodofoneyearfromthedateoforiginalpurchaseagainstdefectsinmanufacture.Thislimitedwarrantyis given by AEMC® Instruments, not by the distributor from whom it waspurchased.Thiswarrantyisvoidiftheunithasbeentamperedwith,abusedorifthedefectisrelatedtoservicenotperformedbyAEMC® Instruments.
For full and detailed warranty coverage, please read the Warranty Cov-erage Information, which is attached to the Warranty Registration Card (if enclosed) or is available at www.aemc.com. Please keep the War-ranty Coverage Information with your records.
What AEMC® Instruments will do:If a malfunction occurs within the one-year period, you may return theinstrument to us for repair, provided we have your warranty registrationinformation on file or a proof of purchase.AEMC® Instruments will, at itsoption,repairorreplacethefaultymaterial.
REGISTER ONLINE AT:www.aemc.com
Warranty RepairsWhat you must do to return an Instrument for Warranty Repair: First, requestaCustomerServiceAuthorizationNumber (CSA#)byphoneorbyfaxfromourServiceDepartment(seeaddressbelow),thenreturntheinstrumentalongwiththesignedCSAForm.PleasewritetheCSA#ontheoutsideoftheshippingcontainer.Returntheinstrument,postageorshipmentpre-paidto: ChauvinArnoux®,Inc.d.b.a.AEMC®Instruments ServiceDepartment 15FaradayDrive•Dover,NH03820USA Tel: (800) 945-2362 (Ext. 360) (603) 749-6434 (Ext. 360) Fax: (603) 742-2346 or (603) 749-6309 repair@aemc.com
Caution:Toprotectyourselfagainstin-transitloss,werecommendyouinsureyourreturnedmaterial.
NOTE: You must obtain a CSA# before returning any instrument.
12 Thermo-Hygrometer Model CA846
NOTES:
Termo-Higrómetro Modelo CA846 13
Table of Contents
1. INTRODUCCIÓN ............................................................................. 141.1 Símbolos Eléctricos Internacionales .......................................141.2 DefinicióndelasCategoríasdeMedición ..............................151.3 RecepcióndeSuEmbarque ...................................................151.4 InformaciónparaponerunaOrden .........................................15
2. CARACTERÍSTICAS DEL PRODUCTO .............................................. 162.1 Descripción .............................................................................162.2 Botones ...................................................................................17
2.2.1 SelectordeFuncionesCentral(Amarillo) ...................17
2.2.2 Botóndeluzposterior y ºC/ºF ..............................172.2.3 BotónMAX ..................................................................172.2.4 BotónHOLD ...............................................................17
3. ESPECIFICACIONES ...................................................................... 183.1 EspecificacionesAmbientales ................................................183.2 EspecificacionesdeMecanicas ..............................................193.3 EspecificacionesdeSeguridad ...............................................19
4. OPERACIÓN .................................................................................. 204.1 Recomendaciones ..................................................................204.2 Operación ...............................................................................20
5. MANTENIMIENTO ......................................................................... 215.1 ReemplazodelaBatería ........................................................215.2 Limpieza .................................................................................21
ReparaciónyCalibración ......................................................................22Asistencia Técnica y de Ventas .............................................................22Garantía Limitada ..................................................................................23ReparacionesbajoGarantía..................................................................23
14 Termo-Higrómetro Modelo CA846
CAPÍTULO 1
INTRODUCCIÓN
Advertencia • No conectar ni tocar ningún circuito eléctrico con enTermo-
Higrómetro.
• Paraevitarheridasoriesgodeincendio,noopereesteproductoenatmósferasoambientesexplosivos.
• CuandouseelTermo-Higrómetroremueva(destornille)eltubometálicoprotectorquecubrelacabezasensora.
• NosumerjalacabezasensoradelTermo-Higrómetroenlíquidos–estopuededañarpermanentementelossensores.
• RepongaeltubometálicoprotectorquecubrelacabezasensoracuandonoestéusandoelTermo-Higrómetro.
1.1 Símbolos Eléctricos Internacionales
Este símbolo significas que el instrumento esta protegido con doble aislamiento.Este símbolo en el instrumento indica una ADVERTENCIA y que el operador deberá consultar el manual del usuario para obtener instrucciones antes de utilizar el instrumento. En este manual, el símbolo anterior a las instrucciones indica que si las instrucciones no se siguen, se pueden provocar, lesión corporal y también se pueden provocar daños en los productos¡Peligro! Riesgo de shock eléctrico. La tensión en la parte marcada con este símbolo puede ser peligroso
De conformidad con WEEE 2002/96/EC
Termo-Higrómetro Modelo CA846 15
1.2 Definición de las Categorías de MediciónCat. I: Para lasmedicionesde los circuitosquenoestándirectamente
conectadasalareddesuministro,talescomotomadecorrientesecundarias protegida, de nivel, y circuitos con limitación decorriente...
Cat. II:Paralasmedicionesrealizadasenloscircuitosconectadodirecta-mentealsistemadedistribucióneléctrica.Ejemplosdeellosonlasmedicionesdelosaparatosdomésticosoinstrumentosportátiles.
Cat. III:Para lasmediciones realizadas en la construcción de la insta-laciónaniveldedistribución, talescomo laconfiguraciónenunequipodeinstalaciónfijaydisyuntores
Cat. IV:Paralasmedicionesrealizadasenelprincipalsuministroeléctrico(<1000),comoenlosdispositivosdeproteccióndesobrecorrienteprimaria,unidadesdecontroldeondulación,omedidores.
1.3 Recepción de Su EmbarqueLuegoderecibidosuembarque,asegúresequeelcontenidocoincideconlaguíadedespacho.Aviseasudistribuidorsobrecualquierpartefaltante.Si el equipo aparece dañado, presente un reclamo inmediatamente altransportadoryavise inmediatamenteasudistribuidor,dandounades-cripcióndetalladadelosdaños.Conserveelempaquedañadoparares-paldarsureclamo.Noutiliceuninstrumentoqueaparezcadañado.
1.4 Información para poner una OrdenTermo-Higrómetro Modelo CA846 ...................................Cat. #2121.24Incluye una batería Alcalina de 9V, un protector gris rugoso a pruebas de golpes y resistente al polvo y manual del usuario
16 Termo-Higrómetro Modelo CA846
CAPÍTULO 2
CARACTERÍSTICAS DEL PRODUCTO
2.1 DescripciónEl Modelo CA846 de AEMC®esunTermo-Higrómetrodigitalportátil,com-pactoyfácildeusardiseñadoparaoperarloconunasolamano.UtilizaunsensorNTCyunsensordehumedadcapacitivoformadoporunapelículadelgadadepolímero.
ElTermo-Higrómetroseentregaconelsensoryunafundaprotectoradegoma.ElModeloCA846poseetambiénunapantalladeLCDconilumi-naciónposterior,unafunciónmantenerlectura(HOLD),yunafunciónderegistro de máximos (MAX).
1.SensorTemperatura/Humedady cubiertaprotectoradelsensor
2. Pantalla de 3½ digitos
3.BotónMAX(Máximo)
4.Selector°C/°FyLuzPosterior
5.BotónHOLD(Guardar)
6. Selector Encendido/Modo (Temp.-RH)
1
2
3 5
64
Termo-Higrómetro Modelo CA846 17
2.2 Botones
2.2.1 Selector de Funciones Central (Amarillo)
DesliceelbotóncentralparaencenderelTermo-Higrómetroyseleccionelaposición%HRoºC/ºF.DesliceelbotónhaciaOFFdespuésdeusarlo.
2.2.2 Botón de luz posterior y ºC/ºF
• Presioneelbotón paraencenderlailuminaciónposterior.
• Presione el botón nuevamente para apagar la iluminación poste-rior.
• Presioneelbotón durante2segundosparacambiarlaescaladetemperaturaaºCoºF.LaescaladetemperaturaºCoºFsemuestraenlaesquinainferiorderechadelapantalla.
2.2.3 Botón MAX
• PresioneelbotónMAXparaentrarenelmodoMAX.Elsímbolo“MAX”apareceenlaesquinasuperiorderechadelapantalla.
• Laescalaseleccionada(%HRoºC/ºF)registrayactualizalosvaloresmáximosabsolutos.
• PresioneelbotónMAXnuevamenteparasalirdelmodode registroMAX(elsímbolo“MAX”desaparece).
• ElbotónHOLD(veaabajo)puedeserusadoenelmodoMAXpara“congelar”(noseactualizamás)lalecturaMAXenlapantalla.
2.2.4 Botón HOLD
El botón HOLD “congela” la lectura en la pantalla. Presione el botón“HOLD”alternadamenteparaactivar/desactivar la funciónHOLD.EnelmodoHOLD,elsímbolo“HOLD”apareceenlapartesuperiordelapanta-llaLCDysemuestralaúltimalecturahastaquesedesactiveestemodo.
18 Termo-Higrómetro Modelo CA846
CAPÍTULO 3
ESPECIFICACIONES
3.1 Especificaciones AmbientalesEscala de Temperatura:Celsius(°C)oFahrenheit(°F)aeleccióndelusuario
Sensor de Temperatura: NTC
Rango de Medición:-4°a140°F,-20°a60°C
Resolución: 0.1°F/°C
Exactitud: 32° a 140°F: ±1°F -4° a 32°F: ±2°F 0° a 60°C: ±0.5°C -20° a 0°C: ±1°C
Coeficiente de Temperatura:0.1veceslaexactitudaplicablepor°Cde0°a18°Cy28°a50°C(32°a64°F y 82° a 122°F)
Sensor de Humedad:Sensor electrónico capacitivo basado en una película de polímero. (Elsensornoesafectadoporcondensacióndeaguayes inmunea lamayoríadelosvaporesdereactivos)
Rango de Medición: 0% a 100%HR
Resolución: 0.1%HR
Exactitud (@ 25°C): 10%-90% HR; ± 5.0% 0%-10% HR; 90% a 100% HR; ± 10.0%
Tiempo de Respuesta del Sensor para 90% del Rango:Valortípico60s
Estabilidad del Sensor:±2%HR,valortípico2años
Histéresis del Sensor (10% a 90% a 10% HR):valortípico±1%HR
Dependencia de la temperatura del Sensor:Despreciablede32°a140°F(0°a60°C)
Termo-Higrómetro Modelo CA846 19
Temperatura de Operación: 32° a 122°F (0° a 50°C) a < 80%HR
Temperatura de Almacenaje:-4°a140°F(-20°a60°C),0a80%HRsinbatería
Exactitud:Exactitudestablecidaa23°C±5°C,<90%HR
Altitud: 2000m máx
Protección de Entrada:Voltajedeentradamáximoencualquierentrada24VCDo24Vrms
3.2 Especificaciones de MecanicasPantalla: Pantalla de cristal líquido (LCD) con dígitos de 3½ y lecturamáxima de 1999
Sobre-Rango:semuestraelsímbolo“OL”
Indicación de Batería Baja:Semuestraelsímbolo cuandoelvoltajede labateríacaebajoelvalorrequerido.
Velocidad de Muestreo:nominal, 2.5vecesporsegundo.
Batería:BateríaEstándarde9V(NEDA1604,IEC6F22006P,oequiva-lente)
Duración de la Batería:Valortípico200horasconbateríadecinc-car-bón
Dimensiones: 6.81 x 2.38 x 1.5 (173 x 60.5 x 38mm)
Peso:Aprox7oz(197g)incluyendobatería
3.3 Especificaciones de Seguridad
EN61010-1(1995-A2),ProtecciónClaseIII
CategoríadeSobrevoltaje(CATIII,24V),ContaminaciónGrado2
Uso Interior
20 Termo-Higrómetro Modelo CA846
CAPÍTULO 4
OPERACIÓN
4.1 Recomendaciones• Paratenermedicionesconfiables,dejequelaslecturasseestabilicen.
Elsensordehumedadyeldetemperaturadebenalcanzarunequili-brio con el medio a medir.
• Evite loserroresen lamediciónde temperatura inducidospor tiem-posdemediciónmuycortos,luzdelsolincidentedurantelamedición,calefacción,murosexternosfríos,corrientesdeaire(Ej.ventiladores),fuentesradiantesinclusivelamanoy/ocalorcorporal,etc.
• Eviteerroresenlamedicióndehumedadinducidosporvapor,salpica-durasdeagua,goterasdeaguaocondensaciónsobreelsensor,etc.
• Evitelacontaminacióndelsensorinducidaporpartículasenelaireomediciones en sustancias polvorientas. La contaminación se puedeevitarefectuandolasmedicionesatravésdeunfiltro(proporcionadoporelusuario).Elfiltrodebeser limpiadoo reemplazadoperiódica-mente,dependiendodelgradodecontaminaciónenelsitiodemedi-ción.
4.2 Operación1. Remuevaeltubometálicoprotectorquecubreelsensor,destornillán-
dolo.
2. Coloqueelinterruptordeencendidoenelrangodeseado%HRoºC/ºF.
3. Dejequela(s)lectura(s)seestabilice(n).El%HRtomaalmenos60segundosenalcanzar90%.
4. Lealapantalla.
5. Despuésdeusarlo,repongaeltubometálicoprotectorquecubreelsensor,atornillándolo.
6. Apagueelinstrumentocuandohayaterminado
Termo-Higrómetro Modelo CA846 21
CAPÍTULO 5
MANTENIMIENTO
Utilicesólorepuestosdefábricaparalamanutención.Elfabricantenosehaceresponsableporaccidentes,incidentes,omalfuncionamientopos-terioresaunareparaciónefectuadaporotrosquenoseansuCentrodeServiciouotrocentrodeservicioautorizado.
5.1 Reemplazo de la BateríaLaenergíaesproporcionadaporunabateríaestándarde9voltios.(NEDA1604,IEC6F22).El símbolo apareceen lapantallaLCDcuandohayque reempla-zarla.
Para reemplazar la batería:• ApagueelHigrómetro.• Remuevalafundadegoma.• Remueva el tornillo en la parte posterior del medidor y levante la
cubiertadelabatería.• Reemplacelabateríayrepongalacubiertaylafunda.
5.2 Limpieza• Periódicamente limpie lacajaconunpañohúmedoyundetergente
suave,siserequiere.• Noutiliceabrasivosnisolventes.• Nopermitaqueentrelíquidoalacajaoalazonadelsensor.
22 Termo-Higrómetro Modelo CA846
Reparación y CalibraciónParaasegurarquesuinstrumentocumpleconlasespecificacionesdefábrica,recomendamosqueloenvíeanuestroCentrodeServicioparare-calibración,anualmenteosegúnlorequieranotrosestándaresoprocedimientosinternos.
Para reparación y calibración del instrumento:DebecontactarnuestroCentrodeServicioparasolicitarunNúmerodeAuto-rizacióndeServicioalCliente(CSA#).Estoaseguraráquecuandollegue,elinstrumentoserá ingresadoyprocesadoconprontitud.Por favorescribaelCSA#enelexteriordelenvase. ChauvinArnoux®,Inc. d.b.a. AEMC®Instruments 15 Faraday Drive Dover,NH03820USA Tel: (800) 945-2362 (Ext. 360) (603) 749-6434 (Ext. 360) Fax: (603) 742-2346 or (603) 749-6309 repair@aemc.com(Ocontactesudistribuidorautorizado)Loscostosdereparaciónycalibraciónestándarestándisponibles.NOTA: Todos los clientes deben obtener un a CSA# antes de enviar cualquier instrumento.
Asistencia Técnica y de VentasSitienecualquierproblematécnicoonecesitaayudaparalacorrectaopera-ciónoaplicacióndesuinstrumentoporfavorllame,escriba,envíeunfaxoe-mailanuestrosoportetécnico: ChauvinArnoux®,Inc. d.b.a. AEMC®Instruments 200FoxboroughBoulevard Foxborough,MA02035,USA Phone: (800) 343-1391 (508) 698-2115 Fax: (508) 698-2118 techsupport@aemc.com www.aemc.com
NOTA: No envíe instrumentos a nuestra dirección en Foxborough, MA.
Termo-Higrómetro Modelo CA846 23
Garantía LimitadaEl Termo-Higrómetro Modelo CA846 es garantizados al propietario pordefectosdefabricación,porunperíododeunañodesdelafechaoriginaldecompra.Estagarantía limitadaesdadaporAEMC® Instruments,noporeldistribuidoraquiensecompróelinstrumento.Estagarantíaquedaviciadasilaunidadhasidointervenida,abusadaosilafallaserelacionaconunservicionorealizadoporAEMC®Instruments.
Para detalles y una descripción completa de la cobertura de la garantía, por favor lea la Tarjeta de Cobertura de Garantía, que se adjunta a la Tar-jeta de Registro de Garantía. Por favor conserve la Tarjeta de Cobertura de Garantía con sus registros.
Lo que AEMC® Instruments hará:Siocurreunafalladefuncionamientodentrodeunaño,ustedpuededevol-vernoselinstrumentoparasureparaciónsincargo,siempreycuandotenga-mossuTARJETADEREGISTROarchivada.AEMC®Instrumentsrepararáoreemplazaráelmaterialdefectuosos,asudiscreción.Sinotenemosarchivadasutarjetaderegistro,lepediremosuncomprobantede compra fechado, como también su TARJETA DE REGISTRO junto almaterialdefectuoso.
Registro En línea en: www.aemc.com
Reparaciones bajo GarantíaLo que Usted debe hacer para enviar un Instrumento para Reparación bajo Garantía: Primero, solicite unNúmerodeAutorización deServicio alCliente (CSA#)porteléfonooporfaxanuestroDepartamentodeServicio(vealadirecciónabajo), luegoenvíeel instrumentojuntoconelformularioCSAfirmado.PorfavorescribaelCSA#enelexteriordelenvase.Envíeelinstrumentoconelfranqueoofleteprepagadoa: ChauvinArnoux®,Inc.d.b.a.AEMC®InstrumentsServiceDepartment 15FaradayDrive•Dover,NH03820USA Tel: (800) 945-2362 (Ext. 360) (603) 749-6434 (Ext. 360) Fax: (603) 742-2346 or (603) 749-6309 repair@aemc.comPrecaución:Paraprotegersecontrapérdidasentránsito,lerecomendamosasegurarsumercadería.NOTA: Todos los clientes deben obtener un CSA# antes de enviar un instrument.
24 Termo-Higrómetro Modelo CA846
NOTAS:
07/08
99-MAN 100240 v5
Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments15FaradayDrive•Dover,NH03820USA•Phone:(603)749-6434•Fax:(603)742-2346