pr app dtl.aspx?param=wGEVXQ - loxwindowsanddoors.com · 3urgxfw $ssurydo 0hwkrg 0hwkrg 2swlrq ' 'dwh 6xeplwwhg 'dwh 9dolgdwhg 'dwh 3hqglqj )%& $ssurydo 'dwh $ssuryhg 6xppdu\ ri 3urgxfwv
Post on 31-Aug-2019
4 Views
Preview:
Transcript
BCIS HomeLog InUser RegistrationHot TopicsSubmit SurchargeStats & FactsPublicationsFBC StaffBCIS Site MapLinksSearch
Product ApprovalUSER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL22331
Application TypeNew
Code Version2017
Application Status Approved
Comments
Archived
Product ManufacturerNan Ya Plastics Corporation USA
Address/Phone/Email8989 North Loop EastHouston, TX 77029(713) 674-7822 Ext 105ajen96@yahoo.com.tw
Authorized SignatureLuis Lomasrllomas@lrlomaspe.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
CategoryExterior Doors
SubcategorySwinging Exterior Door Assemblies
Compliance MethodEvaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Evaluation Report
LUIS ROBERTO LOMAS
Florida LicensePE-62514
Quality Assurance EntityNational Accreditation & Management Institute
Quality Assurance Contract Expiration Date12/31/2018
Validated BySteven M. Urich, PE
Validation Checklist - Hardcopy Received
Certificate of IndependenceFL22331_R0_COI_FLCOI.pdf
Referenced Standard and Year (of Standard)StandardYearTAS 2011994TAS 2021994TAS 2031994
Equivalence of Product StandardsCertified By
Sections from the Code
Page 1 of 2 Florida Building Code Online
1/2/2018 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqs3M6m9%2fK8...
Product Approval MethodMethod 1 Option D
Date Submitted05/03/2017
Date Validated08/09/2017
Date Pending FBC Approval08/09/2017
Date Approved10/10/2017
Summary of Products
FL #Model, Number or NameDescription
22331.16'11" Outswing Hinged Patio Door6'11" Outswing Hinged Patio Door - Impact HVHZ
Limits of UseApproved for use in HVHZ: YesApproved for use outside HVHZ: YesImpact Resistant: YesDesign Pressure: +70.0/-70.0Other: GLAZING INTERLAYER MEET THE REQUIREMENTS
OF THE FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE NOA FOR EASTMAN INTERLAYERS.
Installation InstructionsFL22331_R0_II_08-02985.pdf
Verified By: LUIS ROBERTO LOMAS 62514 Created by Independent Third Party: YesEvaluation ReportsFL22331_R0_AE_513838.pdf
Created by Independent Third Party: Yes
22331.28' Inswing Door LPR (X/XX)8' Inswing Door LPR (X/XX) - Impact HVHZ
Limits of UseApproved for use in HVHZ: YesApproved for use outside HVHZ: YesImpact Resistant: YesDesign Pressure: +50.0/-50.0Other: GLAZING INTERLAYER MEET THE REQUIREMENTS
OF THE FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE NOA FOR KURARAY INTERLAYERS.
Installation InstructionsFL22331_R0_II_08-02983.pdf
Verified By: LUIS ROBERTO LOMAS 62514 Created by Independent Third Party: YesEvaluation ReportsFL22331_R0_AE_513836.pdf
Created by Independent Third Party: Yes
22331.38' Outswing Door SLP (OXX)8' Outswing Door SLP (OXX) - Impact HVHZ
Limits of UseApproved for use in HVHZ: YesApproved for use outside HVHZ: YesImpact Resistant: YesDesign Pressure: +50.0/-50.0Other: GLAZING INTERLAYER MEET THE REQUIREMENTS
OF THE FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE NOA FOR KURARAY INTERLAYERS.
Installation InstructionsFL22331_R0_II_08-02984.pdf
Verified By: LUIS ROBERTO LOMAS 62514 Created by Independent Third Party: YesEvaluation ReportsFL22331_R0_AE_513837.pdf
Created by Independent Third Party: Yes
22331.4Series SLPL Fiberglass Skin Glazed Outswing Door
Series SLPL Fiberglass Skin Glazed Outswing Door
Limits of UseApproved for use in HVHZ: YesApproved for use outside HVHZ: YesImpact Resistant: YesDesign Pressure: +70.0/-70.0Other: GLAZING INTERLAYER MEET THE REQUIREMENTS
OF THE FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE NOA FOR KURARAY INTERLAYERS.
Installation InstructionsFL22331_R0_II_08-02986.pdf
Verified By: LUIS ROBERTO LOMAS 62514 Created by Independent Third Party: YesEvaluation ReportsFL22331_R0_AE_513839.pdf
Created by Independent Third Party: Yes
BackNext
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
Page 2 of 2 Florida Building Code Online
1/2/2018 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqs3M6m9%2fK8...
L. Roberto Lomas P.E. Engineering Evaluation Report 1432 Woodford Rd.
Lewisville, NC 27023 Report No.: 513838 434-688-0609 rllomas@lrlomaspe.com
1 of 2 Luis R. Lomas, P.E. FL No.: 62514
03/14/2017
Manufacturer: Nan Ya Plastics Corp. USA 8989 North Loop East Houston, TX 77029
Product Line: 6’11” Outswing Hinged Patio Door, Impact, HVHZ Compliance: The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of Business and Professional Regulation for Statewide Acceptance per Rule 61G20-3.005 method 1(d). The product listed herein complies with requirements of the current Florida Building Code. Supporting Technical Documentation: 1. Approval document: drawing number 08-02985, prepared, signed and sealed by Luis Roberto Lomas P.E. 2. Test report No.: CTLA 2019W signed and sealed by Ramesh Patel, P.E.
Certified Testing Laboratories, Orlando, FL TAS 201-94 Large Missile Impact Test, Level D, Wind Zone 4 TAS 202 -94 Uniform Static Air Pressure, ±70.0psf design pressure, 10.5psf water penetration. TAS 203-94 Cyclic Pressure loading ±70.0psf design pressure
3. Test report ETC-05-255-16776.1 signed and sealed by Joseph Labora Doldan P.E. ETC Laboratories, Rochester, NY Fiberglass testing ASTM D2843 Smoke density 52.1% ASTM D635 Rate of burning C1 ASTM D1929 Self ignition temperature 1060 oF ASTM D638 Tensile strength unexposed 11,860 psi Tensile strength Xenon arc exposed 11,063 psi
4. Test report ETC-05-255-16777.1 signed and sealed by Joseph Labora Doldan P.E. ETC Laboratories, Rochester, NY Cellular PVC testing ASTM D2843 Smoke density 49.6% ASTM D635 Rate of burning C1 ASTM D1929 Self ignition temperature 950 oF ASTM D638 Tensile strength unexposed 6,019 psi Tensile strength Xenon arc exposed 6,014 psi
5. Test report ETC-05-255-17144-7 signed and sealed by Joseph Labora Doldan P.E. ETC Laboratories, Rochester, NY Rigid PVC testing ASTM D2843 Smoke density 37.4% ASTM D635 Rate of burning C1 ASTM D1929 Self ignition temperature 900 oF ASTM D638 Tensile strength unexposed 6,140 psi Tensile strength Xenon arc exposed 6,053 psi
6. Test report ETC-06-255-17412.1 signed and sealed by Joseph Labora Doldan P.E. ETC Laboratories, Rochester, NY Phenolic Foam testing ASTM E84 flame spread index 10 Smoke developed index 95
7. Test report ETC-06-255-17900.0 signed and sealed by Joseph Labora Doldan P.E. ETC Laboratories, Rochester, NY Phenolic Foam testing ASTM D1929 Self ignition temperature 1100 oF
8. Anchor calculations, report number 513838-1, prepared, signed and sealed by Luis Roberto Lomas P.E.
L. Roberto Lomas P.E. Engineering Evaluation Report 1432 Woodford Rd.
Lewisville, NC 27023 Report No.: 513838 434-688-0609 rllomas@lrlomaspe.com
2 of 2 Luis R. Lomas, P.E. FL No.: 62514
03/14/2017
Limitations and Conditions of use: Maximum design pressure: ±70.0psf Maximum unit size: 108 ½” x 82 ½” Approved configurations: O/XX, XX/O, O/X, X/O, O/XO, XO/O, O/OX, OX/O, XX, X. Units must be glazed per ASTM E1300-04/09, refer to installation instructions for details. This product is rated to be used in the HVHZ. This product is impact resistant and does not require impact protection in wind borne debris regions. Frame material to be foam PVC. Installation: Units must be installed in accordance with manufacturer’s installation instructions and approval document 08-02985. Certification of Independence: Please note that I don’t have nor will acquire a financial interest in any company manufacturing or distributing the product(s) for which this report is being issued. Also, I don’t have nor will acquire a financial interest in any other entity involved in the approval process of the listed product(s).