Transcript

Plan_Checker7v3By Dayanti Pratiwi

• BTS_NAME• CI• X: Longitude• Y: Latitude• CELL_TYPE: Macro, Micro, Indoor• CELL_SYST: DCS, GSM• NUM_SECT:

• #of sector 1 for single cell, > 1 for quasi antennas

• AZM1 to AZM4 (azimuth)• -2 for indoor (small square)• -1 for omni antenna (circle)• If single cell just use AZM1 and

others put 0• NCC• BCC• BCCH• TCH1 to TCH7: put 0 if not use• SIZE (optional): in meter

• Was developed under:• Windows XP• MapInfo/MapBasic 7

• Necessary header/column for bts table:

1 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential

• Necessary header/column for adjacency table (using BTS_NAME format):• SOURCE• TARGET

Plan_Checker7v3By Dayanti Pratiwi

2 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential

• No need to create specific directory nor specific table name• Flexibility format data txt/xls/mdb for input table • Capable for Frequency Checker; Handover Checker; BSIC Checker; KPI Checker• Additional menu for neighbor audit

• Delete/Create HO, the list of deleted/created relation will be recorded in tabnameAudit.TAB

• Mapping the KPI from different table and create the thematic on the map• Three different style of drawing the btstable for your presentation purposes• Connect the measurement data with related cell using Line Connection

Note: Please exit the tools and run again if you found problem cannot draw the btstable, this is bugs from MapInfo7, I cannot fix it

3 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential

4 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential

Arrow style

Clover1 style⇒The DCS and GSM data keep maintain in one table

Clover2 style⇒The DCS and GSM data will be split into two different table

Clover1 style using user defined from column SIZE value

MicroIndoor

Macro GSM

Macro DCS Size = 300

SIZE = 100

Select the coordinate column with XY; and the projection that you useDefault projection is Longitude/Latitude in decimal degree

Follow the instruction on the dialog

Flexible for any data type (txt/xls/mdb)The simplest one is txt format, minimize your mistakes if you forgot to put 0 value when no data

5 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential

6 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential

Quasi omni with 4 antennas direction

indoor

Put 0 value if you have no data

7 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential

Necessary columns are SOURCE & TARGET, the other columns are your own additional data

8 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential

You need to open the btstable first before continue with the checker menus

9 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential

Frequency Checker Menus:Open window frequency checker and then select the freq that you want to check

10 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential

New freq will be checked

Red = co = ch55Blue = co + 1 = ch56Green = co – 1 = ch54

11 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential

Handover Checker Menus:Open window HO checker; Open HO table; and then select the relation that you want to check

12 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential

New HO will be checked

Red = selected bts / SOURCEBlue = adjacencies bts / TARGET

13 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential

Select the bts that you want to add in your neighbor list; and then choose menu Create HO

14 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential

After Ctr+j you will see that the new neighbors were added

15 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential

Select the bts that you want to delete in your neighbor list; and then choose menu Delete HO

16 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential

After Ctr+j you will see that the old neighbors were deleted

17 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential

Your delete/create list result will be saved in the new tableAudit.TAB in the same directory with your other data

When you delete the adjacency from the HO list there will be blank rows in the adce table, you can Packing the HO Table to clean up the blank rows after you finished the neighbor audit

18 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential

BSIC Checker Menus:Open window BSIC checker and then select the BSIC or co BCCH_BSIC that you want to check

19 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential

Check BSIC only, if you want to check co BCCH_BSIC choose menu

20 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential

KPI Checker Menus:Open window KPI checker; Open KPI table; and then select the column kpi that you want to display

Open KPI tableYou can use any data and no need to create specific table/columns name

Column from KPI table that you want to display will be inserted temporarily into BTS table

If you want to modify the previous threshold and redraw the result

21 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential

Line Connection Menus:Open window Line Connection; Open measurement table (TAB format); and then draw the line connection between bts vs measurement point using CI as reference

22 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential

You can use any measurement data (TOM ; TEMS ; etc) as long as you have CI column with integer type in your TAB table

The result will be saved in measnameLine.TAB in the same directory

23 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential

Note: we are using dummy data for the sample

24 © 2005 Nokia Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential

Have a nice day☺

top related