PENDANT MOUNTING GUIDE Multiple Mounting Points · 2020. 7. 15. · PENDANT MOUNTING GUIDE (T) 514-225-4304 (F) 514-931-4862- All right are reserved to Lumenwerx inc. File Name:...
Post on 01-Sep-2020
3 Views
Preview:
Transcript
PENDANT MOUNTING GUIDE W W W . L U M E N W E R X . C O M
www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862- © All right are reserved to Lumenwerx inc. File Name: Pendant-Fixtures-Mounting-Guide-REV1 February 27, 2020 Page: 1 / 7
Lumenwerx ULC. reserves the right to change or modify product specifications without notification.
PLEASE NOTE: GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING APPROPRIATE ANCHORING RODS TO SUPPORT LOAD OF FIXTURES DETAILED ON SHOP DRAWING. PLEASE CALL CUSTOMER SERVICE FOR ANY QUESTIONS
RISK OF FIRE AND ELECTRICAL SHOCK. FIXTURE MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN ONLY IN ACCORDANCE WITH NATIONAL, LOCAL BUILDING AND ELECTRICAL CODES. DISCONNECT POWER AT ELECTRICAL PANEL BEFORE SERVICING.
WARNING
Please specify required canopy type, canopy color, stem ot cable length, stem color, when done enter complete under MOUNTING in the product code.
For custom mounting options please add one of the following options to the end of the mounting code
See Sloped and Seismic guides for detailed informationOptions may vary according to fixture. See product's spec sheet
Multiple Mounting Points
AIR CRAFT AND STEM MOUNTING
CANOPY TYPE CANOPY COLOR HARDWARE CABLE OR STEM LENGTH CUSTOM OPTIONS
53
Power side 5" canopy
Non power side 3" canopy
(available for cable mount only)
W
White
AC
Air Craft Cable
18
18 inches
+SEM
Sesmic Mounting
A
Aluminum
SW
Stem white
24
24 inches
+SLC
Sloped ceiling for cable
55
Power side 5" canopy
Non power side 5" canopy
B
Black
SA
Stem aluminum
36
36 inches
+SLS
Sloped ceiling for stem
####
For all other specify RAL#
SB
Stem black ###
For all other specify length
S#####
For all other stem
color specify RAL#
For required caddy clips please specify under OPTIONS the ceiling type and the ceiling size.
CADDY CLIP OPTIONS
CEILING TYPE
15/16” 9/16” 15/16” 9/16” 9/16”
TG 15/16
Tegular ceiling
TG 9/16
Tegular ceiling
TB 15/16
T-bar ceiling
TB 9/16
T-bar ceiling
ST
Screw slot ceiling
PENDANT MOUNTING GUIDE W W W . L U M E N W E R X . C O M
www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862- © All right are reserved to Lumenwerx inc. File Name: Pendant-Fixtures-Mounting-Guide-REV1 February 27, 2020 Page: 2 / 7
Lumenwerx ULC. reserves the right to change or modify product specifications without notification.
PLEASE NOTE: GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING APPROPRIATE ANCHORING RODS TO SUPPORT LOAD OF FIXTURES DETAILED ON SHOP DRAWING. PLEASE CALL CUSTOMER SERVICE FOR ANY QUESTIONS
RISK OF FIRE AND ELECTRICAL SHOCK. FIXTURE MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN ONLY IN ACCORDANCE WITH NATIONAL, LOCAL BUILDING AND ELECTRICAL CODES. DISCONNECT POWER AT ELECTRICAL PANEL BEFORE SERVICING.
WARNING
Please specify required canopy type, canopy color, stem ot cable length, stem color, when done enter complete under MOUNTING in the product code.
For custom mounting options please add one of the following options to the end of the mounting code
Options may vary according to fixture. See product's spec sheet
Single Mounting Point
AIR CRAFT AND STEM MOUNTING
CANOPY TYPE (see images below) CANOPY COLOR HARDWARE CABLE OR STEM LENGTH
5
5" round canopy
W
White
AC
Air Craft Cable
18
18 inches
5S
5" square canopy
A
Aluminum
SW
Stem white
24
24 inches
SCD
Square canopy driver box
B
Black
SA
Stem aluminum
36
36 inches
RCD
Round canopy driver box ####
For all other specify RAL#
SB
Stem black ###
For all other specify length
LCD
Linear canopy driver box S#####
For all other stem
color specify RAL#
CANOPY TYPE
5
5" round canopy
(shown with an air carft cable)
5S
5" square canopy
(shown with a stem)
SCD
Square canopy driver box
(shown with power over cable)
RCD
Round canopy driver box
(shown with power over cable)
LCD
Linear canopy driver box
(shown with power over cable)
PENDANT MOUNTING GUIDE W W W . L U M E N W E R X . C O M
www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862- © All right are reserved to Lumenwerx inc. File Name: Pendant-Fixtures-Mounting-Guide-REV1 February 27, 2020 Page: 3 / 7
Lumenwerx ULC. reserves the right to change or modify product specifications without notification.
PLEASE NOTE: GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING APPROPRIATE ANCHORING RODS TO SUPPORT LOAD OF FIXTURES DETAILED ON SHOP DRAWING. PLEASE CALL CUSTOMER SERVICE FOR ANY QUESTIONS
RISK OF FIRE AND ELECTRICAL SHOCK. FIXTURE MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN ONLY IN ACCORDANCE WITH NATIONAL, LOCAL BUILDING AND ELECTRICAL CODES. DISCONNECT POWER AT ELECTRICAL PANEL BEFORE SERVICING.
WARNING
TILE CEILING - ON GRID
Power side 5” canopy Non Power side 3” canopy
1
2
3
8
4
9
5
10
6
11
7
12
13
14
15
Armored cable & connector (by others) Junction Box (by others)Support wire (by others)Wire nutCaddy clip (by others)T-Bar grid (by others)Ceiling tile (by others)Caddy clip screw (by others)Power CordCanopy 5" power sidePlastic nutAircraft cableGrip lockWire cable clipCanopy 3" non power side
1054 12
13 14
1
2
34
567
8
910
11
12
13
14
15
PART LIST
15
TILE CEILING - ON GRID
PENDANT MOUNTING GUIDE W W W . L U M E N W E R X . C O M
www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862- © All right are reserved to Lumenwerx inc. File Name: Pendant-Fixtures-Mounting-Guide-REV1 February 27, 2020 Page: 4 / 7
Lumenwerx ULC. reserves the right to change or modify product specifications without notification.
PLEASE NOTE: GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING APPROPRIATE ANCHORING RODS TO SUPPORT LOAD OF FIXTURES DETAILED ON SHOP DRAWING. PLEASE CALL CUSTOMER SERVICE FOR ANY QUESTIONS
RISK OF FIRE AND ELECTRICAL SHOCK. FIXTURE MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN ONLY IN ACCORDANCE WITH NATIONAL, LOCAL BUILDING AND ELECTRICAL CODES. DISCONNECT POWER AT ELECTRICAL PANEL BEFORE SERVICING.
WARNING
TILE CEILING - MOUNTING PLACED OFF GRID
Power side 5” canopy Non Power side 5” canopy
1
2
3
8
4
9
5
10
6
11
7
12
13
14
15
16
Juction box support (by others) T-bar grid (by others)Ceiling Tile (by others)Junction Box (by others) Power CordCanopy 5" power sidePlastic nutArmored cable & connector (by others) Wire nutJunction Box screw (by others)Junction box crossbar1/4"-20 Crimp studAircraft cableGrip lockWire cable clipCanopy 5" non power side
6 7 9 13 14 1511
PART LIST
1
2
3
4
5
6
8
7
9
10111213
14
15
16
TILE CEILING - MOUNTING PLACED OFF GRID
PENDANT MOUNTING GUIDE W W W . L U M E N W E R X . C O M
www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862- © All right are reserved to Lumenwerx inc. File Name: Pendant-Fixtures-Mounting-Guide-REV1 February 27, 2020 Page: 5 / 7
Lumenwerx ULC. reserves the right to change or modify product specifications without notification.
PLEASE NOTE: GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING APPROPRIATE ANCHORING RODS TO SUPPORT LOAD OF FIXTURES DETAILED ON SHOP DRAWING. PLEASE CALL CUSTOMER SERVICE FOR ANY QUESTIONS
RISK OF FIRE AND ELECTRICAL SHOCK. FIXTURE MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN ONLY IN ACCORDANCE WITH NATIONAL, LOCAL BUILDING AND ELECTRICAL CODES. DISCONNECT POWER AT ELECTRICAL PANEL BEFORE SERVICING.
WARNING
DRYWALL CEILING
Power side 5” canopy Non Power side 3” canopy
1
2
3
8
4
9
5
10
6
11
7
12
13
14
15
16
17
18
Ceiling structure (by others)Drywall (by others)Screw (by others)Junction Box (by others) Power CordCanopy 5" power sidePlastic nutArmored cable & connector (by others) Wire nutJunction box crossbar1/4"-20 Crimp studJunction Box screw (by others)Aircraft cableGrip lockWire cable clip1/4"-20 Treated rod (by others)Canopy 3" non power side1/4"-20 Cable holder
6 7 9 13 14 1810
PART LIST
1
8
9
10
11
12
13
14
15
16
17
18
3
2
4
5
6
7
17
DRYWALL CEILING
PENDANT MOUNTING GUIDE W W W . L U M E N W E R X . C O M
www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862- © All right are reserved to Lumenwerx inc. File Name: Pendant-Fixtures-Mounting-Guide-REV1 February 27, 2020 Page: 6 / 7
Lumenwerx ULC. reserves the right to change or modify product specifications without notification.
PLEASE NOTE: GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING APPROPRIATE ANCHORING RODS TO SUPPORT LOAD OF FIXTURES DETAILED ON SHOP DRAWING. PLEASE CALL CUSTOMER SERVICE FOR ANY QUESTIONS
RISK OF FIRE AND ELECTRICAL SHOCK. FIXTURE MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN ONLY IN ACCORDANCE WITH NATIONAL, LOCAL BUILDING AND ELECTRICAL CODES. DISCONNECT POWER AT ELECTRICAL PANEL BEFORE SERVICING.
WARNING
SOLID CEILING
Power side 5” canopy Non Power side 5” canopy
1
2
3
8
4
9
5
10
6
11
7
12
13
14
15
Ceiling surface material (by others)Screw (by others)Junction Box (by others) Power CordCanopy 5" power sidePlastic nutArmored cable & connector (by others) Wire nutJunction box crossbar1/4"-20 Crimp studJunction box screw (by others)Aircraft cableGrip lockWire cable clipCanopy 5" non power side
5 6 8 12 139
PART LIST
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
SOLID CEILING
14
PENDANT MOUNTING GUIDE W W W . L U M E N W E R X . C O M
www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862- © All right are reserved to Lumenwerx inc. File Name: Pendant-Fixtures-Mounting-Guide-REV1 February 27, 2020 Page: 7 / 7
Lumenwerx ULC. reserves the right to change or modify product specifications without notification.
PLEASE NOTE: GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING APPROPRIATE ANCHORING RODS TO SUPPORT LOAD OF FIXTURES DETAILED ON SHOP DRAWING. PLEASE CALL CUSTOMER SERVICE FOR ANY QUESTIONS
RISK OF FIRE AND ELECTRICAL SHOCK. FIXTURE MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN ONLY IN ACCORDANCE WITH NATIONAL, LOCAL BUILDING AND ELECTRICAL CODES. DISCONNECT POWER AT ELECTRICAL PANEL BEFORE SERVICING.
WARNING
STEM MOUNT IN DRYWALL CEILING
Power side 5” canopy Non Power side 5” canopy
1
2
3
8
4
9
5
10
6
11
7
12
13
Ceiling structure (by others)Drywall (by others)Screw (by others)Junction Box (by others) Power CordCanopy 5" power sideArmored cable & connector (by others) Wire nutJunction box crossbarJunction box screw (by others)StemStem slip ringCanopy 5" non power side
8 11 129
PART LIST
1
2
3
4
5
6
7
8
9
10
11
12
13
6 13
STEM MOUNT IN DRYWALL CEILING