PC Wiring System Series PCW - SMC Pneumatics · PDF filePC Wiring System Series Connection cable with connector P. 12 ... PC Wiring System Series PCW 1. ... Connected to PLC via connection
Post on 24-Mar-2018
219 Views
Preview:
Transcript
CAT.ES02-20 A
PC Wiring System
Series PCW
The PC wiring system is a revolutionary new system that simplifieswiring between a PLC and all types of connected equipment.
Features 1
Input32
points
Output64 points
CompatiblePLC Manufacturers
24VDCPowersupply
OMRON CorporationMitsubishi Electric CorporationFuji Electric Co., Ltd.Hitachi Ltd.Toshiba CorporationYasukawa Electric CorporationSHARP CorporationYokogawa Electric Corporation Matsushita Electric WorksKeyence CorporationKoyo Electronics Industries Co., Ltd. Branch unit
PLC directconnected type
16 point input unitBox mount type
16 point input unitDIN rail mount type
16 point output unitDIN rail mount type
8 point output unit (terminalblock type) DIN rail mount type
HI
16points
32points
32points
16 points
16 points
16points
Branch unitDIN rail
mount type
With 16 points separated
With 16 points unseparated
16 points
16 points
Input Output
P. 2
P. 3
P. 6
P. 6
P. 6
With 32 points separatedWith 32 points unseparated
Connectioncablewith connector
P. 12
Connectioncable with connector
P. 13
32 pointreduced
common typealso available.
P. 5
32 point output unitDIN rail mount type
32 points
Output32
points
Output32
points
A revolutionary new wiring system...
Series PCW
Features 2
LO
16points
16points
32points
16 points
8 points
P. 4
P. 8
P. 14
PC Wiring System
Series PCW
Connectioncable withconnector
P. 12
Connectioncable withconnector
P. 11
Connection cablewith connector
P. 13
Check unit
t
s
The PC wiring system simplifies wiring between a P
Features 3
PC wiring system terminal block unit (40P connector + 64 pin terminal block + Added value)
General purpose terminal block unit (40P connector + 40 pin terminal block)
Standard specifications Fujitsu Ltd. FCN connector specifications
In the case of a general purpose terminal block, common and power supply terminal blocks are not supplied as shown below, making it necessary to purchase them separately. Labor is also required for assembly.
In the case of the PC wiring system terminal block unit, it is only necessary to purchase one piece and nothing else is required. (It is also compact, and the PLC manufacturer's address is stated directly on the label.)
P. 11, 12, 13
Commonality achieved with branch unit
Simple parallel type
Improved wiring efficiency and ease of handling
Fujitsu Ltd. FCN connector specifications also available.
Connection cable
Space saving
Commonality achieved with branch unit The branch unit separates each PLC manufacturer's 32 point I/O into a 16 point common pin layout.
Conversion to a common pin layout makes it possible to connect the pin layout to SMC manifold solenoid valves and other manufacturers' relay equipment without even thinking about it.
Power can be supplied to the PLC's I/O unit.
Compatible branch units are available for each PLC manufacturer's I/O.
Simple parallel type Unlike serial transmission, there is no need to worry about transmission delay time.
Visually and sensually easy to understand, maintenance is easy for start-up, debugging and trouble shooting.
Improved wiring efficiency and ease of handling Reduced wiring equivalent to a serial transmission system can be attained with a special cable.
The single block pressure connection system using a connector allows standardization of wiring work, prevents miswiring and greatly improves work efficiency.
Fujitsu Ltd. FCN connector specifications also available.
Consult SMC regarding compatibility.
Connection cable The special cable with power supply line consists of a flat cable and power supply lines enclosed in a single sheath, making the conventional separate wiring of the power supply line unnecessary.
Maximum wiring length 49m
Also available without the power supply lines specification.
Space saving
a PLC and all types of connected equipment.
Features 4
Connected to manifold solenoid valves
With input from a sensor switch, etc. Reduces wiring labor Prevents miswiring Requires fewer I/O points
PC Wiring System Application Examples
Example
1
Example
2
Manifold solenoid valves(16 point output)
Branch unit(32 point output 16 point output x 2)
PLC (32 point output)
Manifold solenoid valves(16 point output)
Input unit(16 point input)
Input unit(8 point input)
Cascade connectionInput unit (8 point input)
Branch unit(32 point input 16 point input x 2)
PLC(32 point input)
Reduces wiring labor Prevents miswiring Commercially available relay terminals, etc., can also be connected
24VDC
2A
0.3A
5MΩ or more at 100VDC
0.5kV
500m/s²
0.4 to 0.6Nm/0.4 to 0.7Nm
0.5 to 0.6Nm/0.5 to 0.7Nm
7mm
AWG26 to 14 (0.13 to 2.5mm²)
AWG26 to 12 (0.13 to 4mm²)
Common Specifications
Cable Specifications
Rated voltage
Rated current
Insulation resistance
Withstand voltage
Impact resistance
Flat cable
Power lines
Sheath O.D.
Power supply line
Communication line
Power terminal (Phillips screwdriver/Flat head screw driver)I/O terminal (Phillips screw driverFlat head screw driver)
Power terminal
I/O terminal
Power terminal
I/O terminal
Brown
Blue
PVC sheath
Flat cableAWG28
Power linesAWG20 (20, 40 cores)
With power lines
AWG28 (7 wires/0.127mm)
AWG20 (21 wires/0.18mm) ——
20 cores
10.3mm
40 cores
12.0mm
20 cores
8.7mm
34 cores
11.8mm
40 cores
13.0mm
Without power lines
Screwtighteningtorque
Wire strippinglength(recommended)
Connecting wire size
Term
inal
blo
cksp
ecifi
catio
ns
PC Wiring System
Series PCW
1
18.2
(5.2)16.5
CN1CN2
1NDN–1D/1
–+
70.1
23.127.4
+ –
Dimensions
Specifications
Weight
Ambient temperature
25g
–25 to 55°C
Compatible PLC's and Models
PLCmanufacturer
OMRONCorporation
Mitsubishi Electric
Corporation
YokogawaElectric Corp.
I/Opoints
32
32
32
64
64
64
Input
Compatible model Model Model
Output
PCW-993155
PCW-993106
PCW-993104
C200H-ID216C200H-ID218
A1SX41
F3XD32-3N
F3XD64-3N
AX42A1SX42
C500-ID219C200H-ID217C200H-ID219
Note 1)
Note 3) PCW-993156
PCW-993107
PCW-993105
C200H-OD218
C500-OD213C200H-OD219
A1SY41
F3YD32-1A
F3YD64-1A
AY42A1SY42 Note 2)
Note 4)
CautionWhen removing a cable with connector, a PCW-04T puller is required.
Two pieces are required for 64 points of input/output.Note 1) Combine one piece each of PCW-993106 and PCW-993108 (the PLC connection side connectors are
reversed).Note 2) Combine one piece each of PCW-993107 and PCW-993109 (the PLC connection side connectors are
reversed).Note 3) Combine one piece each of PCW-993155 and PCW-993174 (the PLC connection side connectors are
reversed).Note 4) Combine one piece each of PCW-993156 and PCW-993175 (the PLC connection side connectors are
reversed).
PLC connection
Can be directly mounted on PLC.
PLC
Compatible model
Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page 1.
Series PCWBranch Unit: PLC Direct Connected Type
2
Dimensions
Specifications
Weight
Ambient temperature
80g
–25 to 80°C
Compatible PLC's and Models
PLCmanufacturer
OMRONCorporation
MitsubishiElectric
Corporation
Fuji ElectricCo., Ltd.
Hitachi, Ltd.
Toshiba Corp.
Yasukawa Electric
SHARPCorporation
MatsushitaElectric Works
Koyo ElectronicsIndustries Co., Ltd.
Keyence Corp.
YokogawaElectric Corp.
I/Opoints
32
32
32
32
32
64
64
64
64
64
64
64
64
64
64
Input Output
PCW-993023A
C200H-ID216C200H-ID218CQM1-ID213
KZ-C32X Note 1)
PCW-993033A
PCW-993015A PCW-993017A
PCW-993019A PCW-993021A
PCW-993029A PCW-993039A
C200H-OD218CQM1-OD213
C500-ID219C200H-ID217C200H-ID219
A1SX41AJ35TC1-32D
AX42A1SX42
AY42A1SY42
A1SY41AJ35TC1-32T
FTU125ANS-X64-I
FTU222ANS-Y64-TI
PCW-993025A PCW-993035ADI335DI-6241
DO335DO-6242
JW-34NCJW-234N
JW-32SCJW-232S
AFP33027AFP33028AFP33068
AFP33487
XDC24D2H YTR24DH
PCW-993049A PCW-993043A
PCW-993045A PCW-993047A
PCW-993027A PCW-993037A
PCW-993168A PCW-993169A
U-19TPCW-993200A PCW-993201A
PCW-993139A PCW-993140A
JAMSC-B2605 JAMSC-B2604
JW-64NC JW-62SC
F3XD32-3N F3YD32-1A
F3XD64-3N
U-09N
F3YD64-1A
C500-OD213C200H-OD219
KZ-C32T Note 1)
28.3
45
103
16.7
(3.6)
4.1
5.1
10.5 10.5
OUTIN
ID!/4-A
CNO
CN2CN1
C1 C2 8 7 6 5 4 3 2 1
RS–
4950.5
4.5
55
Two pieces are required for 64 points of input/output.Note 1) The mounted connector has 34 pins.
PLC connection
Connected to PLC via connection cable.
PLC
Compatible model Model Compatible model Model
Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page 1.
∗ Refer to pages 11 and 13 for the junction cable part number.
Series PCWBranch Unit: DIN Rail Mount Type
3
Keyence Corp.
Compatible PLC's and Models
Two pieces are required for 64 points of input/output.Note 1) The mounted connector has 34 pins.
OMRONCorporation
MitsubishiElectric
Corporation
Fuji ElectricCo., Ltd.
Hitachi, Ltd.
Toshiba Corp.
Yasukawa Electric
SHARPCorporation
MatsushitaElectric Works
32
32
32
32
32
64
64
64
64
64
64
64
64
64
64
PCW-990344A
C200H-ID216C200H-ID218CQM1-ID213
KZ-C32XNote 1)
PCW-990345A
PCW-993157A PCW-993158A
PCW-993159A PCW-993160A
PCW-990355A PCW-990356A
C200H-OD218CQM1-OD213
C500-ID219C200H-ID217C200H-ID219
A1SX41AJ35TC1-32D
AX42A1SX42
AY42A1SY42
A1SY41AJ35TC1-32T
FTU125ANS-X64-I
FTU222ANS-Y64-TI
PCW-990386A PCW-990387ADI335DI-6241
DO335DO-6242
JW-34NCJW-234N
JW-32SCJW-232S
AFP33027AFP33028AFP33068
AFP33487
XDC24D2H YTR24DH
PCW-993011A PCW-993012A
PCW-993163A PCW-993164A
PCW-993013A PCW-993014A
PCW-993166A PCW-993167A
U-19TPCW-993202A PCW-993203A
PCW-993161A PCW-993162A
JAMSC-B2605 JAMSC-B2604
JW-64NC JW-62SC
F3XD32-3N F3YD32-1A
F3XD64-3N
U-09N
F3YD64-1A
C500-OD213C200H-OD219
KZ-C32T Note 1)
Dimensions
Specifications
Weight
Ambient temperature
210g
–25 to 55°C
53.555
4.5
55
1 1F1F1616D40
+
E F 1010 1111 1212 1313 1414 1515 1717 1818 1919 1A1A 1B1B 1C1C 1D1D 1E1E
-+-+-+-+-+-+-+-+-+-
C
+
B
-
A
+
9
-
8
+
7
-
6
+
5
-+
3
-
2
+-
16.7
45 28.3
178
4.1
10.510.5
5.1
OUTINAX/140-A
01 CHCH
RS–
(3.6)
(3.7)
PLC connection
Connected to PLC via connection cable.
PLC
PLCmanufacturer
I/Opoints
Input Output
Compatible model Compatible model ModelModel
Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page 1.
∗ Refer to page 11 for the junction cable part number.
Koyo ElectronicsIndustries Co., Ltd.
YokogawaElectric Corp.
Series PCW32 Point Input/Output Unit
4
OMRONCorporation
Mitsubishi Electric
Corporation
ToshibaCorporation
Fuji ElectricCo., Ltd.
YokogawaElectric Corp.
Keyence Corp.
Output points
32
32
32
32
64
64
64
64
64
Compatible model Model
PCW-993224
PCW-993222
PCW-993223
PCW-993225
PCW-993194
PCW-993193
C200H-OD218CQM1-OD213
AY42A1SY42
A1SY41AJ35TC-32T
DO335DO-6242
F3YD32-1A
F3YD64-1A
KZ-C32T
FTU222ANS-Y64-T1
C500-OD213C200H-OD219
Note 1)
Compatible PLC's and Models
Two pieces are required for 64 points of output.Note 1) The mounted connector has 34 pins.
Dimensions
Specifications
Weight
Ambient temperature
130g
–25 to 55°C
4.5
113
131211
112111110
1098
109108107
765
106105
4
104103
32
102
15
115
14
114
1
101100
0+
-
53.555
OD/040LPOUT
CH1
–
+
CH
RS–
113
28.3
45
16.7
103
5.1
4.1
10.5 10.5(3.6)
(3.7)
PLC connection
Connected to PLC via connection cable.
PLC
PLC manufacturer
Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page 1.
∗ Refer to page 11 for the junction cable part number.
Series PCW32 Point Output Reduced Common Unit
5
Dimensions
Models
Input
OutputPCW-993051APCW-993052A
Specifications
Weight
Ambient temperature
125g
–25 to 80°C
Terminal Block: DIN Rail Mount Type
5553.5
–
F
+
E
–
D
+
C
–
B
+
A
–
9
+
8
–
7
+
6
–
5
+
4
–
3
+
2
–
10
+–
+
4.5
55
28.3
45103
16.7IN
OUT
CN1
RS-
CHF16/1D-A
10.5 10.5
(3.7) 5.1
4.1
PCW-993055APCW-993056A
480g
–25 to 80°C
Terminal Block: Box Mount Type
33.5139
59
–– + –+ – v– + –– ++ –– + – +
+FEDCBA9875 642 31+ 0
INOUT
1 2 C1
0/118-A
C2
–
+
CN
1
CN
2
CH
(3.7
)
(3)158
55
8
6
67.4
10
40
1614 16 1614 1614
41.2(2)
65
1.2
4-M3 x 0.5 2-ø5 machined for bar ringMounting hole5
101055 55
2525
55 55
6-ø4
2-ø8
Dimensions
Models Specifications
Input
Output
Weight
Ambient temperature
Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page 1.
Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page 1.
Series PCW16 Point Input/Output Unit
6
PCW-993132APCW-993133A
70g
–25 to 80°C
Connector: DIN Rail Mount Type
Output PCW-993195 80g
–25 to 80°C
Terminal Block: DIN Rail Mount V Type16 Point Output Reduced Common Unit
4.5
16.7
4.1
5.1113
28.3
4510.510.5 103
4950.5
F16/1DTB–A
–S+
321
21
IN
CH
CN–PS
CN–FCN–ECN–D
CN–5
CN–C
CN–4
CN–8
CN–3
CN–A
CN–2
CN–9
CN–1CN–PC
CN–6CN–7
RS–CN–0
CN–8
–+
(3.6)
53.55579
28.3
45
16.7
69
4.5
5.1
4.1
10.5 10.5
F16/0DLPOUT
4
CB
32
A
765
F]ED
1
98
0+
–
–
+
L
HCH
RS–
(3.6)
(3.7)
CautionConnectors are manufactured by Molex Japan Co., Ltd., and are not handled by SMC.Please order them separately.Housing: 51103-0300Crimp pin: 50351-8100
Input
Output
Weight
Ambient temperature
Dimensions
Model Specifications
Weight
Ambient temperature
Dimensions
Model Specifications
Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page 1.
Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page 1.
Series PCW16 Point Input/Output Unit
7
Dimensions
PCW-993053APCW-993054A
105g
–25 to 80°C
Terminal Block: DIN Rail Mount Type
Dimensions
PCW-993057APCW-993058A
365g
–25 to 80°C
Terminal Block: Box Mount Type
5553.5
28.3
45
103
4.5
16.7
CH
––– –– –– –––
+764 5320+
F8/1D-A
CN2CN1
HL
76543210
+
–
1 2 3 4 C
1
RS–
55
10.5 10.5
4.1
5.1(3.7)
59
33.599118
55
8
1.2
4-M3 x 0.52-ø5 machined for bar ringMounting hole
51010
667
.4
10
2525
40
701614 16 1614
41.2(2)
65
70
2-ø8
4-ø4
–+ ––++– –– +
+75 6431 20+
OUTIN
1 2 C1
D/18-A
L
H
0 1 2 3 4 5 6 7
–
+
C2
CN
2
CN
1
CH
(3.7
)
(3)
7
6
1
0L H
……
7
6
1
0
HL
……
Models
Input
Output
Specifications
Weight
Ambient temperature
Models
Input
Output
Specifications
Weight
Ambient temperature
Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page 1.
Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page 1.
HI/LO setting(8 point input/output unit) Since most PLC manufacturers use 16 points of input/output in units of one channel, 8 point input/output units can be connected in a series of two units. In this case, either the “Lo” 0 to 7 or “Hi” 8 to F address can be selected by means of these jumpers (short-circuit sockets). To select the “Lo” side address the “Lo” side is shorted. It is set to the “Lo” side when shipped from the factory.
Note) When two 8 point input/output units are used in a cascade connection, set the jumpers (short-circuit sockets) so that the jumpers (short-circuit sockets) of both units are not set to the same address (i.e., not “Lo” and “Lo” or Hi” and “Hi”).(Trouble will occur during input due to the activation of OR circuits for two sensors.)Use caution, because incorrect connection of input and output for 8 point or 16 point input/output units following the branch unit, will cause short-circuiting of the power supply.
“Hi”“Lo”
Series PCW8 Point Input/Output Unit: HI/LO Setting Type
8
Dimensions
HI
LO
HI
LO
PCW-993210PCW-993211PCW-993212PCW-993213
105g
–25 to 80°C
Terminal Block: DIN Rail Mount Type
Dimensions
365g
–25 to 80°C
Terminal Block: Box Mount Type
Models
HI
LO
HI
LO
Input
Output
PCW-993214PCW-993215PCW-993216PCW-993217
F8/ID-A
113 5553.5
28.3
45103
4.5
16.7
OUTIN
1 2
C1
C2
––– –– –– –––
–FEC DBA8–
CN2CN1
+
–
9
HICH
RS–
10.5 10.5
4.1
5.1(3.7)
67.4
(2)(2) 41.2118
702-ø5
HI OUTIN
1 2 C1
MDP/18H
–
+
C2
CN
2
CN
1
CH
HI/LO limit typeFor this type, the upper or lower position is fixed, and it is not necessary to set jumpers (short-circuit sockets).Lo type: The address assignment is fixed at “Lo” 0 to 7.Hi type: The address assignment is fixed at “Hi” 8 to F.
Specifications
Weight
Ambient temperature
Specifications
Weight
Ambient temperature
Models
Input
OutputNote) Since some series PCW specifications are
included in the common specifications, also refer to the common specifications on page 1.
Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page 1.
Series PCW8 Point Input/Output Unit: HI/LO Limit Type
9
Dimensions
Models
HI (master) Input
Output
PCW-993135APCW-993136A
Specifications
Weight
Ambient temperature
75g
–25 to 80°C
Connector: DIN Rail Mount Type
Master
Dimensions
Models
LO (slave) Input
Output
PCW-993137APCW-993138A
Specifications
Weight
Ambient temperature
55g
–25 to 80°C
SlaveCN1PS
Address
4.5
5.179
4.1
16.7
10.510.5 69
28.3
45
4950.5
F8/1D2TB-A +–0
000
LH
CHCN-3 (B) CN-2 (A) CN-1 (9) CN-0 (8)
CN-7 (F) CN-6 (E) CN-5 (D)
IN
CN-4(C) –S+
321
1
2
RS-
CN-PC1
+
(3.6)
4.5
4.1
16.7
5.1113
45 28.3
10.510.5 103
4950.5
F8/1D1TB-A
+–
CN-PS2CN-PS1RS-
21001
CH CN-PC2CN-PC1
1 2 3
+ S –
CN-7CN-6CN-5CN-4CN-3CN-2CN-1CN-0
IN
–
+–+
(3.6)
Manifold solenoid valves
CN-PC1 CN-PC2
Address 8 to FAddress 0 to 7
Connector type8 point output unit(master)
8 point relay terminalMatsushita Electric WorksRT1S-OD08-V-SRT1S-ID08-V-S
CN-PC1
Address 8 to FAddress 0 to 7
Connector type8 point I/O unit(slave)
Connector type8 point I/O unit(master)
Connector type8 point I/O unit(slave)
CN-PC1 CN-PC1CN-PC2
Address 8 to FAddress 0 to 7
1. 2. 3.
Cascade connection examples (Consult with SMC in case of a cascade connection.)
CautionConnectors are manufactured by Molex Japan Co., Ltd., and are not handled by SMC. Please order them separately.Housing: 51103-0300, Crimp pin: 50351-8100
Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page 1.
Note) Since some series PCW specifications are included in the common specifications, also refer to the common specifications on page 1.
Cascade connectionA connector type 8 point input/output unit can be used with a cascade connection of a master unit and slave unit, or a cascade connection of a master unit with another device.Note) Connector type input/output units are not available with HI/LO settings.
1st unit: Connector type 8 point input/output unit(master unit)
2nd unit: Connector type 8 point input/output unit(slave unit)
1st unit: Connector type 8 point output unit(master unit)
2nd unit: Manifold
1st unit: Relay terminal2nd unit: Connector type 8 point input/output unit
(slave unit)
Series PCW8 Point Input/Output Unit: HI/LO Limit Type
10
For Connection of PLC Input/Output Card to PCW Unit
PCW 02
Power supply lineYesNo
SymbolNilN
Lead wire length0.5m1m1.5m2m3m5m
Symbol005010015020030050
Power supply line
SpecificationsStandard specificationsFor connection of PCW unit for Keyence Corp. PLC I/O card (KZ-C32X, KZ-C32T)For connection of PCW unit for Hitachi, Ltd. PLC I/O card (XDC24D2H, YTR24DH)
Symbol020506
Specifications
005Lead wire length
• PLC input/output card to PCW branch unit• PLC input/output card to PCW 32 point unit
DimensionsSeries PCW-02
With power linesPLC connection side
PCW unit connection side
Fujitsu FCN40 pin connector
MIL-C-8350340 pin connector
Without power linesPLC connection side
PCW unit connection side
Fujitsu FCN40 pin connector
MIL-C-8350340 pin connector
Series PCW-05 With power linesPLC connection side PCW unit connection side
MIL-C-8350334 pin connector
MIL-C-8350334 pin connector
Without power linesPLC connection side PCW unit connection side
MIL-C-8350334 pin connector
MIL-C-8350334 pin connector
Series PCW-06 With power linesPLC connection side PCW unit connection side
MIL-C-8350340 pin connector
MIL-C-8350340 pin connector
Without power linesPLC connection side PCW unit connection side
MIL-C-8350340 pin connector
MIL-C-8350340 pin connector
Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above.
Note) When using a PCW unit equipped with Fujitsu FCN connector, contact your SMC sales representative as the connector cable is different.
Series PCWPC Wiring SystemConnector Cable
11
Dimensions
With power lines
Branch unit: PLC direct connecting typeconnection side
Branch unit: PLC direct connecting typeconnection side
PCW unit connection side
IDEC Izumi JM1S20 pin connector
MIL-C-8350320 pin connector
Without power lines
PCW unit connection side
IDEC Izumi JM1S20 pin connector
MIL-C-8350320 pin connector
Branch Unit:Connection of PLC Direct Connecting Type
to PCW Unit
PCW 04
Power supply linesYesNo
SymbolNilN
Lead wire length0.5m1m1.5m2m3m5m
Symbol005010015020030050
Power supply lines
005Lead wire length
Branch Unit:Connection of PLC Direct Connecting Type
to Manifold Solenoid Valves
PCW 04
Powersupply lines
YesNo
Applicable manifoldsolenoid valve kit
G kitJ kit
Symbol
VN
Lead wire length0.5m1m1.5m2m3m5m
Symbol005010015020030050
Power supply lines
005Lead wire length
Refer to the section starting on page 16 for details regarding applicable manifold solenoid valves.
With power lines
Branch unit: PLC direct connecting typeconnection side
Branch unit: PLC direct connecting typeconnection side
Manifold solenoid valve connection side
(G kit)
Manifold solenoid valveconnection side
(J kit)
IDEC Izumi JM1S20 pin connector
MIL-C-8350320 pin connector
Without power lines
IDEC Izumi JM1S20 pin connector
MIL-C-8350320 pin connector
Dimensions
V
• Branch unit: Connection of PLC direct connecting type to PCW 16 point unit
• Branch unit: Connection of PLC direct connecting type to PCW 8 point unit
Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above.
• Branch unit: Connection of PLC direct connecting type to manifold solenoid valves
Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above.
Series PCWPC Wiring SystemConnector Cable
12
Dimensions
With power lines
PCW unit connection side
MIL-C-8350320 pin connector
MIL-C-8350320 pin connector
Without power lines
PCW unit connection side
PCW unit connection side
PCW unit connection side
PCW unit connection side
PCW unit connection side
MIL-C-8350320 pin connector
MIL-C-8350320 pin connector
Connection ofPCW Unit to PCW Unit
PCW 01
Power supply linesYesNo
SymbolNilN
Lead wire length
0.5m1m1.5m2m3m5m
Symbol005010015020030050
Power supply lines
005Lead wire length
Connection of PCW Unit to Manifold Solenoid Valves
PCW 01
Lead wire length
0.5m1m1.5m2m3m5m
Symbol005010015020030050
005Lead wire length
With power linesManifold solenoid valve connection side
(G kit)
Manifold solenoid valve connection side (J kit)
MIL-C-8350320 pin connector
MIL-C-8350320 pin connector
Without power lines
MIL-C-8350320 pin connector
MIL-C-8350320 pin connector
Dimensions
V
Power supply lines
YesNo
Applicable manifoldsolenoid valve kit
G kitJ kit
Symbol
VN
Power supply lines
Refer to the section starting on page 16 for details regarding applicable manifold solenoid valves.
• Connection of PCW branch unit to PCW 16 point unit
• Connection of PCW branch unit to PCW 8 point unit
• Connection of PCW 8 point unit to PCW 8 point unit
• Connection of PCW branch unit to manifold solenoid valves
• Connection of PCW 8 point unit to manifold solenoid valves
Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above.
Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above.
13
Series PCWPC Wiring SystemConnector Cable
24VDC
0.3A
0.5kV
0.4 to 0.6Nm/0.4 to 0.7Nm
7mm
AWG26 to 14 (0.13 to 2.5mm²)
–25 to 80°C
Specifications
Dimensions
How to Order
Internal Circuit Diagram
Rated voltage
Rated current
Withstand voltage
Thread tightening torque(Phillips screw driver/Flat head screw driver)
Wire stripping length
Connecting wire size
Ambient temperature
• Effective for software/hardware debugging and maintenance of PC wiring systems and other compatible systems.
• Signal monitoring possible with LED.
• Switches allow forced release and forced ON operation of connections between connectors in one bit increments.
• Allows voltage measurement and wave form observation of signals between the check terminal and common terminal.
PCW 993065
Check unit
Term
inal
blo
ck
116 22.5
(41)
130 (149
)
Series PCWCheck Unit
14
15
Manifold ValvesP. 18
P. 34
P. 54
5 Port Solenoid Valve
Series SQ1000/2000 • Low profile compact manifold• Stacking manifold type makes it easy to increase or decrease
the number of stations• Maintenance of valves is simplified by the one-screw mounting• A variety of options
Back pressure check valve, Built-in silencer, Name plate, etc.• Seal type allows selection of metal seals or rubber seals
Rubber Seal5 Port Solenoid Valve
Series SZ3000 • Size and weight reductions have been realized by eliminating the manifold base• The plug-in cassette system makes valve replacement easy• A plug-in manifold has been achieved with a height of 43.5mm (including DIN rail)• Valves with switches are available to allow each valve to be turned off individually• 4 position dual 3 port valve provided by combining two 3 port valves in one valve
body• Valve with back-pressure check function available• Low power consumption: 0.65W (with light)
(Current value: 27mA, 24VDC)
Rubber Seal5 Port Solenoid Valve
Series SX3000/5000 • Low power consumption: 0.65W
(with light)(Current value: 27mA, 24VDC)
• Compact with high flow rateCv factor 1.7 to 3 times greater with same body width as previous series
• High reliabilityLong life exceeding 50 million cycles
• Main valve and pilot valve common exhaust construction eliminates pilot valve exhaust mist and noise
Rubber Seal5 Port Solenoid Valve
Series SY3000/5000 • Low power consumption: 0.55W (with light)
(Current value: 23mA, 24VDC) • Compact with high flow rate
Cv factor 1.7 to 3 times greater with same body width as previous series
• High reliabilityLong life exceeding 50 million cycles
• Main valve and pilot valve common exhaust construction eliminates pilot valve exhaust mist and noise
5 Port Solenoid ValveBody Ported Type/Flip Plug-in Unit
Series VQ1000 • Compact manifold for efficient use of space• Valves can be replaced without disassembling the entire manifold• Seal type allows selection of metal seals or rubber seals
5 Port Solenoid ValveBase Mounted Type/Plug-in Unit
Series VQ1000/2000 • Space saving design locates all pilot valves on one side• One-clamp construction with no screws for easy valve replacement• A variety of options
Back pressure check valve, Built-in silencer, Name plate, etc.
• Seal type allows selection of metal seals or rubber seals
P. 44
P. 28
16
Manifold Electrical Wiring
Common Shared Wiring Connectors
• With power supply terminals (G kit) • Without power supply terminals (J kit)
SOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.B
201816141210861917151311975
3.4
1.2
–+
Terminal no.
Electrical circuit diagram (The wiring below indicates all double solenoid connections)
1 station
24VDC
2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations
SOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.BSOL.ASOL.B
20181614121086
1917151311975
3.4 24VDC (–)
1.2 24VDC (+)
Terminal no.
Electrical circuit diagram (The wiring below indicates all double solenoid connections)
1 station 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations
Common shared wiring connector assemblies are also available for series SX/SZ. Refer to the catalog for each series for details.
Applicable seriesSeries SZ3000Series SX3000/5000Series SY3000/5000Series VQ1000/2000 (base mounted type)
Applicable seriesSeries SQ1000/2000Series VQ1000 (body ported) Series VQ1000/2000 (base mounted type)
For standard electrical wiring specifications, the internal wiring for up to eight stations is double wiring (connected to SOL.A and SOL.B) for each station regardless of the valve or option type. Connect to SOL.A in case of single solenoids. Furthermore, when mixed single and double wiring is required, indicate this on a manifold specification sheet. (except Series SY)
For standard electrical wiring specifications, the internal wiring for up to eight stations is double wiring (connected to SOL.A and SOL.B) for each station regardless of the valve or option type. Connect to SOL.A in case of single solenoids. Furthermore, when mixed single and double wiring is required, indicate this on a manifold specification sheet.
Manifold Valve Common Specifications
17
top related