Pap Smear Technique

Post on 24-Jan-2017

301 Views

Category:

Documents

7 Downloads

Preview:

Click to see full reader

Transcript

Operational Obstetrics & Gynecology · Bureau of Medicine and Surgery · 2000 Slide 1

Pap Smear Technique

Video

Operational Obstetrics & Gynecology · Bureau of Medicine and Surgery · 2000 Slide 2

Positioning

• Privacy• Buttocks just off table• Good Lighting• Drape• Standby

Operational Obstetrics & Gynecology · Bureau of Medicine and Surgery · 2000 Slide 3

Padded Stirrups

• Soft, padded stirrups• Oven mitts• Socks• Battle dressings

Operational Obstetrics & Gynecology · Bureau of Medicine and Surgery · 2000 Slide 4

Inspect

• Spread labia• Discharge• Ulcers• Growths

Operational Obstetrics & Gynecology · Bureau of Medicine and Surgery · 2000 Slide 5

Anatomy

Operational Obstetrics & Gynecology · Bureau of Medicine and Surgery · 2000 Slide 6

Vaginal Speculum

Operational Obstetrics & Gynecology · Bureau of Medicine and Surgery · 2000 Slide 7

Warm Speculum• Warm water• Not too hot• Lubricates speculum• Don’t use K-Y,

Surgilube or Vaseline to lubricate speculum

Operational Obstetrics & Gynecology · Bureau of Medicine and Surgery · 2000 Slide 8

Insert Speculum• Spread labia• Keep labia apart• Blades remain closed

until fully inserted

Operational Obstetrics & Gynecology · Bureau of Medicine and Surgery · 2000 Slide 9

Squamo-Columnar Junction• Junction of pink cervical skin

and red endocervical canal• Inherently unstable • Key portion of the cervix to

sample• Most likely site of dysplasia

Operational Obstetrics & Gynecology · Bureau of Medicine and Surgery · 2000 Slide 10

Ayers Spatula• Concave end to fit the

cervix• Convex end for vaginal

wall and vaginal pool scrapings

Operational Obstetrics & Gynecology · Bureau of Medicine and Surgery · 2000 Slide 11

Sample Cervix• Use concave end • Rotate 360 degrees• Don’t use too much force

(bleeding, pain)• Don’t use too little force

(inadequate sample)

Operational Obstetrics & Gynecology · Bureau of Medicine and Surgery · 2000 Slide 12

Cytobrush• Insert ~ 2 cm (until brush

is fully inside canal)• Rotate only 180 degrees

(otherwise will cause bleeding)

Operational Obstetrics & Gynecology · Bureau of Medicine and Surgery · 2000 Slide 13

Make Pap Smear• As thin as possible• Properly labeled

Operational Obstetrics & Gynecology · Bureau of Medicine and Surgery · 2000 Slide 14

Spray with Fixative• Within 10-15 seconds• Allow to fully dry

before packaging• Cytologic Fixative

(hairspray works acceptably also)

top related