NIOS 701 Release Notes

copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 1 of 21 400-0579-001 Rev A 1212015

INTRODUCTION 2

Supported Platforms 2

NEW FEATURES 5

NIOS 700 5

CHANGES TO DEFAULT BEHAVIOR 7

NIOS 700 7 NIOS 6x Releases 7

CHANGES TO Infoblox API and RESTful API 7

RESTful API Deprecation and Backward Compatibility Policy 8 NIOS 70x 8 NIOS 6x Releases 8

UPGRADE GUIDELINES 9

Upgrading to NIOS 70x 9

BEFORE YOU INSTALL 10

ACCESSING GRID MANAGER 12

ADDRESSED VULNERABILITIES 12

RESOLVED ISSUES 13

Fixed in 701 13 Fixed in 700 13

KNOWN GENERAL ISSUES 16

NIOS 701 Release Notes

copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 2 of 21 400-0579-001 Rev A 1212015

INTRODUCTION Infoblox NIOS 70x software coupled with Infoblox appliance platforms enables customers to deploy large robust manageable and cost-effective Infoblox Grids This next-generation solution enables distributed delivery of core network servicesmdashincluding DNS DHCP IPAM TFTP and FTPmdashwith the nonstop availability and real-time service management required for todayrsquos 24x7 advanced IP networks and applications Please note the following

bull NIOS 70x releases are not supported on the following appliances IB-250-A IB-550-A IB-1050-A IB-1550-A IB-1552-A IB-1852-A IB-2000 IB-2000-A IB-VM-250 IB-VM-550 IB-VM-1050 IB-VM-1550 IB-VM-1850 IB-VM-2000 and Trinzic Reporting TR-2000 series appliances You cannot upgrade to NIOS 70x on these appliances See Upgrade Guidelines on page 9 for additional upgrade information

bull NIOS 70x releases do not support the IF-MAP service You cannot upgrade Infoblox Orchestration Servers to NIOS 70 and later The IF-MAP service is supported in 51r2-IBOS-1 600-IBOS-1 IBOS 210 and later releases For more information visit the Infoblox Support web site at httpssupportinfobloxcom

Supported Platforms Infoblox NIOS 70x is supported on the following platforms bull NIOS Appliances

- Infoblox Advanced Appliances PT-1400 PT-2200 and PT-4000 - Network Insight Appliances ND-800 ND-1400 ND-2200 and ND-4000 - Trinzic Appliances TE-100 TE-810 TE-820 TE-1410 TE-1420 TE-2210 TE-2220 and Infoblox-4010 - All Trinzic Rev-1 and Rev-2 appliances (For more information about Trinzic Rev-2 appliances refer to

KB article 17748 available on the Infoblox Support web site at httpssupportinfobloxcom) - Cloud Network Automation CP-V800 CP-V1400 and CP-V2200 - Trinzic Reporting TR-800 TR-1400 TR-2200 and TR-4000 - Infoblox-4030 DNS Caching Accelerator Appliance

bull vNIOS for VMware on ESXESXi Servers

The Infoblox vNIOS on VMware software can run on ESX or ESXi servers that have DAS (Direct Attached Storage) or iSCSI (Internet Small Computer System Interface) or FC (Fibre Channel) SAN (Storage Area Network) attached You can install the vNIOS software package on a host with VMware ESX or ESXi 41 50 51 or 55 installed and configure it as a virtual appliance Note that IB-VM-100 virtual appliances can only run on ESXi 51 servers vSphere vMotion is also supported You can migrate vNIOS virtual appliances from one ESX or ESXi server to another without any service outages The migration preserves the hardware IDs and licenses of the vNIOS virtual appliances VMware Tools is automatically installed for each vNIOS virtual appliance Infoblox supports the control functions in VMware Tools For example through the vSphere client you can shut down the virtual appliance You can deploy certain vNIOS virtual appliances with different hard disk capacity Some vNIOS appliances are not supported as Grid Masters or Grid Master Candidates Note that the IB-VM-800 and IB-VM-1400 virtual appliances are designed for reporting purposes For more information about vNIOS on VMware refer to the Infoblox Installation Guide for vNIOS Software on VMware For information about vNIOS virtual appliances for reporting refer to the Infoblox Installation Guide for vNIOS Reporting Virtual Appliances

NIOS 701 Release Notes

copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 3 of 21 400-0579-001 Rev A 1212015

bull vNIOS for Microsoft Server 2008 R2 and 2012 R2 Hyper-V The Infoblox vNIOS virtual appliance is now available for Windows Server 2008 R2 and Windows Server 2012 R2 that have DAS (Direct Attached Storage) Administrators can install vNIOS virtual appliance on Microsoft Windowsreg servers using either Hyper-V Manager or SCVMM A Microsoft Powerscript is available for ease of installation and configuration of the virtual appliance Note that vNIOS for Hyper-V is not recommended as a Grid Master or Grid Master Candidate With this release you can deploy certain vNIOS appliances with a 50 GB 55 GB or 160 GB hard disk You can also deploy the IB-VM-800 and IB-VM-1400 virtual appliances as reporting servers For more information about vNIOS for Hyper-V refer to the Infoblox Installation Guide for vNIOS on Microsoft Hyper-V

bull vNIOS for Xen Hypervisor The Infoblox vNIOS for Xen is a virtual appliance designed for Citrix XenServer 61 and 62 running Xen hypervisor and for Linux machines running Xenprojectorg 43 hypervisor You can deploy vNIOS for Xen virtual appliances as the Grid Master Grid members or reporting servers depending on the supported models Note that the IB-VM-800 virtual appliances are designed for reporting purposes only For more information about vNIOS for Xen refer to the Infoblox Installation Guide for vNIOS for Xen Hypervisor For information about vNIOS virtual appliances for reporting refer to the Infoblox Installation Guide for vNIOS Reporting Virtual Appliances

The following table shows available vNIOS virtual appliances and their specifications

Trinzic Series Virtual Appliances

Disk (GB)

of CPU Cores

Memory Allocation

Virtual CPU Core Frequency

vNIOS for VMware

vNIOS for MS Hyper-V

vNIOS for Xen

Supported as Grid Master and Grid Master Candidate (YesNo)

IB-VM-100 55 1 1 GB 1300 MHz No

IB-VM-800 (for reporting only

1 GB daily limit)

50 2 Range 2 ndash 8 GB

Default 8 GB

3000 MHZ No

IB-VM-800 (for reporting only

2 GB daily limit)

50 2 Range 4 ndash 8 GB

Default 8 GB

3000 MHZ No

IB-VM-810 55 2 2 GB 2000 MHz No

IB-VM-810 160 2 2 GB 2000 MHz Yes

IB-VM-820 55 2 2 GB 3000 MHz No

IB-VM-820 160 2 2 GB 3000 MHz Yes

IB-VM-1400 (for reporting only

5 GB daily limit)

55 4 Default 8 GB

8000 MHz No

IB-VM-1410 55 4 8 GB 6000 MHz No

NIOS 701 Release Notes

copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 4 of 21 400-0579-001 Rev A 1212015

IB-VM-1410 160 4 8 GB 6000 MHz Yes

IB-VM-1420 160 4 8 GB 8000 MHz Yes

IB-VM-2210 160 4 12 GB 12000 MHz Yes

IB-VM-2220 160 4 12 GB 12000 MHz Yes

Network Insight Virtual Appliances

Disk (GB)

of CPU

Cores

Memory Allocation

Virtual CPU Core

Frequency

vNIOS for

VMware

vNIOS for MS

Hyper-V

vNIOS for Xen

Supported as Grid Master and Grid Master Candidate (YesNo)

ND-VM-800 160 2 8 GB 3000 MHz No

ND-VM-1400 160 4 16 GB 8000 MHz No

ND-VM-2200 160 4 24 GB 24000 MHz No

Cloud Platform Virtual Appliances

Disk (GB)

of CPU

Cores

Memory Allocation

Virtual CPU Core

Frequency

vNIOS for

VMware

vNIOS for MS

Hyper-V

vNIOS for Xen

Supported as Grid Master and Grid Master Candidate (YesNo)

CP-V800 160 2 2 GB 2000 MHz No

CP-V1400 160 4 8 GB 6000 MHz No

CP-V2200 160 4 12 B 12000 MHz No vNIOS for VMware on Cisco UCS ExpressSRE-V

The Infoblox vNIOS on VMware software can also run on Cisco SRE-V (Services Ready Engine Virtualization) which is part of the Cisco UCS (Unified Computing System) Express Infoblox has certified running vNIOS for VMware on Cisco SRE-V v15 (for ESXi 41) and v20 (for ESXi 50) Cisco SRE-V enables the VMware vSphere Hypervisor to be provisioned on Cisco SRE 700710 and 900910 Service Modules The Cisco SRE Service Module can reside in the Cisco 2900 and 3900 series ISRs G2 The following table lists the supported vNIOS on VMware virtual appliances on SRE 700710 and SRE 900910

vNIOS on VMware Virtual Appliances

Disk (GB) of CPU Cores

Memory Allocation

Virtual CPU Core

Frequency

Cisco SRE 700710

Cisco SRE 900910

IB-VM-810 55 2 2 GB 2000 MHz No Yes

IB-VM-810 160 2 2 GB 2000 MHz No Yes

IB-VM-820 55 2 2 GB 3000 MHz No Yes

IB-VM-820 160 2 2 GB 3000 MHz No Yes

NIOS 701 Release Notes

copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 5 of 21 400-0579-001 Rev A 1212015

Note that all vNIOS on VMware virtual appliances running on Cisco SRE-V are not recommended as Grid Masters or Grid Master Candidates The IB-BOB virtual appliance has been renamed to IB-VM-100 For new installation use the 55 GB software image IB-VM-100 only supports configuration as a Grid member

bull vNIOS on Riverbedreg Steelhead Appliances

Infoblox has certified the vNIOS on Riverbed software with the following Riverbed Steelhead models and software versions

Riverbed Models Supported RiOS and EX versions

1050 2050 5050 RiOS 75 RiOS 80 RiOS 85

EX560 EX760 EX1160 EX1260 EX 10 (RiOS 7) EX 20 (RiOS 80) EX 25 (RiOS 80) EX 30 (RiOS 850) EX 31 (RiOS 851)

For additional information refer to the Infoblox Installation Guide for vNIOS Software on Riverbed Steelhead Platforms NOTE You can upgrade a Grid with a Riverbed virtual member to NIOS 7x Ensure that the Riverbed model has 64 bit support

NEW FEATURES This section lists new features in the 70x releases NIOS 700 Cloud Network Automation The Infoblox Cloud Network Automation solution automates IPAM (IP address management) for physical and virtual network devices on your CMP (Cloud Management Platform) Instead of manually provisioning IP addresses and DNS name spaces for network devices and interfaces you can use Cloud Network Automation to provision and manage IPAM DNS and DHCP within the Grid automatically as VMs (Virtual Machines) are created and destroyed When your Cloud consists of a large number of servers and VMs (virtual machines) that have multiple associated network interfaces manually provisioning and de-provisioning IP addresses and managing DNS and DHCP data can be error-prone and time consuming Utilizing Cloud Network Automation minimizes human errors by streamlining IP Address and DNS record management improves visibility of your cloud networks and maximizes the flexibility efficiency and agility of your cloud environment Cloud Network Automation includes two components the Grid Master that has a Cloud Network Automation license installed and one or more Cloud Platform Appliances The Cloud Network Automation license enables visibility and reporting on cloud tenant network VM IP address and DNS record allocation Cloud Platform Appliances enable processing of API requests from your CMP locally on the same appliances that serve DNS and DHCP to your cloud These appliances provide local survivability and additional scalability of Cloud API requests within your data centers in addition to the visibility provided by the Cloud Network Automation license on the Grid Master DNS Traffic Control Infoblox DNS Traffic Control provides a load balancing solution by adjusting DNS responses based on DNS query source IP server availability and network topology Through DNS Traffic Control you can set up multiple global sites and configure supported objects and load balancing methods to direct responses to the best available servers

NIOS 701 Release Notes

copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 6 of 21 400-0579-001 Rev A 1212015

Support for IPv6 Grid

The Infoblox appliance now supports IPv6 networking configuration in most deployments You can deploy a Grid and configure a Grid Master Grid Member reporting member and an HA pair in one of the following modes IPv4 only IPv6 only or IPv4 and IPv6 dual mode You can also configure the default communication protocol settings using IPv4 or IPv6 In addition services and functionality such as NTP service DNS Firewall and admin notifications now support both IPv4 and IPv6 addresses In addition Grid communication can now support IPv6 only and you can configure an appliance with only IPv6 addresses (no IPv4 addresses are required) Support for Microsoft Sites This release enhances the Microsoft Management solution by adding support for managing Microsoft Active Directory Sites and Subnets on Microsoft servers through Grid Manager DNS Firewall Enhancements This release adds the following enhancements for DNS Firewall

bull Threat severity levels for RPZ zones bull Threat details in the syslog bull Categorization and filtering for DNS and Advanced DNS Protection syslog messages bull Severity level in the DNS Top RPZ Hits report

Automated Mitigation of Phantom Domain Attacks This release provides a few CLI commands for mitigating phantom domain attacks in which a flood of queries are sent to resolve non-existent domains When phantom domain attacks happen the recursive server continues to query non-responsive servers spending valuable resources waiting for responses When resources are fully consumed the recursive server may drop legitimate queries causing serious performance issues To mitigate phantom domain attacks you can use the following CLI commands to control queries to non-responsive servers set holddown set fetches_per_server set fetches_per_zone and set recursion_query_timeout For information about these commands refer to the Infoblox CLI Guide DNSSEC Enhancement You can now add multiple cryptographic algorithms that the Grid Master uses when it generates the KSK and ZSK When you add multiple algorithms at the Grid level you can override them at the zone level By default the appliance uses RSASHA1 for both KSK and ZSK You can now add DSA RSAMD5 RSASHA1 RSASHA-256 or RSASHA-512 algorithms Configuring Fixed Addresses without Restarting DHCP Service When you configure or modify a fixed address a DHCP service restart is required by default in order for the new configuration to take effect You can now override this default behavior by enabling the appliance to take immediate action without restarting DHCP service when you configure or modify a fixed address that is outside a DHCP range You can enable this feature at the Grid or member level For Cloud Network Automation deployment this feature is automatically enabled on the Cloud Platform Appliance that has a valid Cloud Platform license installed Ignoring MAC Addresses for New Leases In addition to the UID (unique client identifier) you can now set the DHCP server to ignore the MAC address (hardware address) of a DHCP client when it places a request to the DHCP server for a new lease When you configure the appliance to ignore the MAC addresses of DHCP clients you can specify up to 10 MAC addresses to be ignored

NIOS 701 Release Notes

copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 7 of 21 400-0579-001 Rev A 1212015

Name Server Groups for Delegated Zones When you configure a name server group you can now create a set of external name servers as a delegation name server group and assign it to delegated zones Specifying a single delegation name server group instead of configuring multiple name servers individually for delegated zones can significantly reduce configuration efforts Network Insight Assets for Trunk Reports Device discovery now includes in the Asset tab all hosts (physical and virtual) connected to a trunk port Reporting Enhancement This release adds the capability to email reporting search results Infoblox API and RESTful API Enhancement This release adds newly supported objects for the API and RESTful API CHANGES TO DEFAULT BEHAVIOR This section lists changes to default behavior in NIOS 70x and 6x releases NIOS 700

bull Starting with this release you must have IPv6 addresses for both nodes in an HA pair if one of them has an IPv6 address This was optional in previous releases

bull In previous releases when you apply a non-global DHCP option filter to a DHCP range the appliance may return option 43 in the response Starting with this release the appliance does not return option 43 in any responses when you apply a non-global DHCP option filter to a range

NIOS 6x Releases bull In previous releases you could configure DHCP Option 60 (Vendor Class Identifier) match rules

associated with Microsoft option_space in the Grid or member DHCP properties or DHCP option filters associated with Microsoft option_space Starting with this release these configurations are no longer supported and you cannot configure them

bull Reporting The ldquoDomain Namerdquo and ldquoMitigation Actionrdquo filters are no longer supported in the Top RPZ Hits by Client report

bull In previous releases the appliance added grace period to the KSK (Key Signing Key) and ZSK (Zone Signing Key) rollover periods In this release the rollover periods for a particular zone start as soon as it is signed

bull In previous releases you could assign read-only permission for hosts in a network to restrict admins to only viewing hosts in the specified network In this release assigning read-only permission for hosts in a network does not affect the visibility of hosts in the specified network

CHANGES TO Infoblox API and RESTful API This section lists changes made to the Infoblox API and RESTful API in NIOS releases For detailed information about the supported methods and objects refer to the latest versions of the Infoblox API Documentation and the Infoblox WAPI Documentation available through the NIOS products and on the Infoblox Support web site The latest available RESTful API version is 20

NIOS 701 Release Notes

copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 8 of 21 400-0579-001 Rev A 1212015

RESTful API Deprecation and Backward Compatibility Policy This policy covers the interfaces exposed by the Infoblox RESTful API and the protocol used to communicate with it

Unless explicitly stated in the release notes previously available RESTful API versions are intended to remain accessible and operative with later versions

The planned deprecation of a given version of the RESTful API will normally be announced in the release notes at least one year in advance Upon deprecation the announced RESTful API version and all prior versions will no longer be supported in subsequent releases For example if the current RESTful API release is v34 and the release notes contain an announcement of the v15 deprecation v14 and v15 API requests would continue to work with later releases for one year from the announcement date After that some or all requests for these deprecated versions may not work with versions later than v15 API requests adherent to versions later than v15 (v20 for example) would continue to work with subsequent releases Infoblox seeks to avoid any deprecation that has not been announced in advance however product modifications and enhancements may affect specific API requests without a prior announcement Infoblox does not warrant that all API requests will be unaffected by future releases This policy applies to both major and minor versions of the RESTful API Infoblox reserves the right to change this policy NIOS 70x

bull When executing a RESTful API request from version 20 and later the XML data format has been updated to accommodate tag names (used primarily in extensible attributes) that contain spaces andor invalid XML characters

NIOS 6x Releases

bull The RESTful API (WAPI) sample code advises using curl -k3 to access the RESTful API through SSLv3 SSLv3 is no longer supported and the ndashk3 option in curl is no longer supported To correctly use curl to access the RESTful API specify curl -k1 to force the use of TLS

bull The following changes for keytabs have been made in the Infoblox API

remove_datakeytab has been removed

import_datakeytab has been removed

import_dataupload_keytab has been added

The API also supports multiple TSIG keys To use a keytab you must upload it and manually assign it to individual members or to DHCP you cannot complete this task in one operation If you have only one keytab you can still use the old gss_tsig members However Infoblox recommends that you switch to the new gss_tsig_keysipv6_gss_tsig_keys members

bull The following objects have been deprecated in the Infoblox API

InfobloxGridMSServerDNS (new object InfobloxGridMSServerServerDNS)

status_last_updated member in InfobloxGridMSServerDNS (new object status_last_updated_ts member in epoc format)

Though the deprecated objects will continue to function for backward compatibility purposes Infoblox recommends that you use the new objects in your new code

bull The InfobloxGridAdminUser object password method and the InfobloxGrid object secret method have been modified to adhere to Infoblox security policies

NIOS 701 Release Notes

copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 9 of 21 400-0579-001 Rev A 1212015

bull API and RESTful API After upgrading to NIOS 67x all international domain names (IDNs) in punycode are converted to Unicode (in the respective API way of encoding Unicode strings) You can use the dns_[hellip] fields in relevant objects to retrieve read-only IDNs in punycode For more information about IDNs refer to the Infoblox NIOS Administrator Guide For information about API and RESTful API refer to the Infoblox API Documentation and Infoblox RESTful API Documentation

UPGRADE GUIDELINES Upgrading to NIOS 70x NOTES

bull You cannot upgrade NIOS 6124 to NIOS 70x You will however be able to upgrade NIOS 6124 and later to NIOS 71x releases when they become available

bull You cannot upgrade directly from NIOS 5x to NIOS 70x However you can first upgrade to NIOS 66x or later and then to NIOS 70x

You cannot upgrade to NIOS 70x on the following appliances IB-250-A IB-550-A IB-1050-A IB-1550-A IB-1552-A IB-1852-A IB-2000 IB-2000-A IB-VM-250 IB-VM-550 IB-VM-1050 IB-VM-1550 IB-VM-1850 IB-VM-2000 and Trinzic Reporting TR-2000 series appliances For information about supported platforms see Supported Platforms on page 1 Note the following for IPv6 Grid support

bull If your Grid Master is configured with an IPv6 VIP all Grid Master Candidates must also include an IPv6 VIP For an HA pair both nodes of the HA pair must have IPv6 addresses for the Grid Master and the Grid Master Candidate

bull After you upgrade to NIOS 70x Infoblox recommends that you back up the configuration after you change network connectivity to a different mode (IPv4 IPv6 or IPv4 and IPv6 dual mode) Restoring an old backup by performing a forced restore may prevent some Grid members from rejoining the Grid after the restore

bull IPv6-only configuration does not support the following HSM LCD NAT groups OSPF and BGP

When you schedule a full upgrade from a previous release to NIOS 70x the following DNSSEC limitations are applicable

bull You cannot configure new settings that are added to the authoritative zone object while the upgrade is still in progress This restriction is not applicable to future upgrades

bull When you upgrade you can sign or unsign an authoritative zone only if the Grid Master Candidate and the associated serving members are upgraded This restriction is not applicable to future upgrades

bull An authoritative zone can have its KSK rollover only if the Grid Master Candidate and all the serving members are upgraded This restriction is not applicable to future upgrades

bull An authoritative zone can have its ZSK rollover by the daemon only if the Grid Master Candidate and all the serving members are upgraded This restriction is not applicable to future upgrades

bull You cannot delete keys while the upgrade is still in progress bull You cannot update DNSSEC related parameters at the member level while the upgrade is still in

progress Example rollover mechanism NSEC3 salt length and iterations and enable or disable automatic KSK rollover

NIOS 701 Release Notes

copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 10 of 21 400-0579-001 Rev A 1212015

For Cloud Network Automation bull After upgrading to NIOS 70x you must manually select the Delegated To Cloud Usage

and Owned By columns in the Data Management tab of Grid Manager to display relevant information This is applicable only if you have installed the Cloud Network Automation license on the Grid Master

BEFORE YOU INSTALL To ensure that new features and enhancements operate properly and smoothly Infoblox recommends that you evaluate the capacity on your Grid and review the upgrade guidelines before you upgrade from a previous NIOS release Infoblox recommends that administrators planning to perform an upgrade from a previous release create and archive a backup of the Infoblox appliance configuration and data before upgrading You can run an upgrade test before performing the actual upgrade Infoblox recommends that you run the upgrade test so you can resolve any potential data migration issues before the upgrade Following is a list of upgrade and revert paths You can also schedule a full upgrade from these releases 700 6122 and earlier 612x releases 6117 and earlier 611x releases 610201 and 610200 61010 and earlier 610x releases 69201-LD and 69200-LD 690 6813 and earlier 68x releases 678 and earlier 67x releases 6613 and earlier 66x releases Technical Support Infoblox technical support contact information

Telephone 1-888-463-6259 (toll-free US and Canada) +1-408-625-4200 ext 1

E-mail supportinfobloxcom

Web httpssupportinfobloxcom

GUI Requirements Grid Manager supports the following operating systems and browsers You must install and enable Javascript for Grid Manager to function properly Grid Manager supports only SSL version 3 and TLS version 1 connections Infoblox recommends that you use a computer that has a 2 GHz CPU and at least 1 GB of RAM

NIOS 701 Release Notes

copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 11 of 21 400-0579-001 Rev A 1212015

Infoblox supports the following browsers for Grid Manager

OS Browser Microsoft Windows 80 and 81reg Microsoft Internet Explorerreg 11x 10x

Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

Microsoft Windows 7reg Microsoft Internet Explorerreg 11x 10x 9x and 8x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

Microsoft Windows XPreg (SP2+) Microsoft Internet Explorer 7x and 8x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

Red Hatreg Enterprise Linuxreg 7x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

Red Hatreg Enterprise Linuxreg 6x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

Red Hatreg Enterprise Linux 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

Applereg Mac OS X 109x Safari 7x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

Applereg Mac OS X 108x Safari 6x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

Applereg Mac OS X 107x Safari 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

Applereg Mac OS X 106x Safari 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

NOTE Grid Manager fully supports Microsoft Internet Explorerreg 11x and 10x when you enable compatibility view in the browser Features in the Reporting tab may not function properly if you disable compatibility view In the browser go to Tools -gt Compatibility View to enable the feature When viewing Grid Manager set the screen resolution of your monitor as follows

Minimum resolution 1280 x 768 Recommended resolution 1280 x 1024 or better

Documentation You can download the Infoblox NIOS Administrator Guide from the appliance From Grid Manager expand the Help panel and then click Documentation -gt Admin Guide Training Training information is available at httpinterviewcentralcomeventsuploadsinfobloxloginhtml

NIOS 701 Release Notes

copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 12 of 21 400-0579-001 Rev A 1212015

ACCESSING GRID MANAGER Before you log in to Grid Manager ensure that you have installed your NIOS appliance as described in the installation guide or user guide that shipped with your product and configured it accordingly To log in to Grid Manager

1 Open an Internet browser window and enter httpsltIPv4 address or hostname of your NIOS appliancegt or https[IPv6 address] of your NIOS appliance The Grid Manager login page appears

2 Enter your user name and password and then click Login or press Enter The default user name is admin and password is infoblox

3 Read the Infoblox End-User License Agreement and click I Accept to proceed Grid Manager displays the Dashboard your home page in Grid Manager

ADDRESSED VULNERABILITIES This section lists security vulnerabilities that were addressed in the past 12 months For vulnerabilities that are not listed in this section refer to Infoblox KB 2899 For additional information about these vulnerabilities including their severities please refer to the National Vulnerability Database (NVD) at httpnvdnistgov The Infoblox Support website at httpssupportinfobloxcom also provides more information including vulnerabilities that do not affect Infoblox appliances CERT VULNERABILITY NOTE CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation CERT VULNERABILITY NOTE CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet CERT VULNERABILITY NOTE CVE-2014-3566 SSL3 is vulnerable to man-in-the-middle-attacks SSL3 is disabled in NIOS and connections must use TLSv1 (which is already used by all supported browsers)

CERT VULNERABILITY NOTE CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

CERT VULNERABILITY NOTE CVE-2014-7187 Off-by-one error in the read_token_word function in parsey in GNU BASH through v 43 allowed remote attackers to cause a denial of service (out-of-bounds array access and application crash) or possibly an unspecified impact through deeply nested for loops (also known as the word_lineno issue)

CERT VULNERABILITY NOTE CVE-2014-7186 The redirection implementation in parsey in GNU BASH through v 43 allowed remote attackers to cause a denial of service (out-of-bounds array access and application crash) or possibly an unspecified impact through the redir_stack issue

CERT VULNERABILITY NOTE CVE-2014-6271 CVE-3014-6277 CVE-2014-6278 AND CVE-2014-7169 GNU Bash through v 43 processed trailing strings after function definitions in the values of environment variables which allowed remote attackers to execute arbitrary code via a crafted environment (also known as the ShellShock vulnerability)

NIOS 701 Release Notes

copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 13 of 21 400-0579-001 Rev A 1212015

CERT VULNERABILITY NOTE CVE-2014-3470 Enabling anonymous ECDH cipher suites on TLS clients could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0224 A specially crafted handshake packet could force the use of weak keying material in the SSLTLS clients allowing a man-in-the-middle (MITM) attack to decrypt and modify traffic between a client and a server CERT VULNERABILITY NOTE CVE-2014-0221 Remote attackers could utilize DTLS hello message in an invalid DTLS handshake to cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0198 Enabling SSL_MODE_RELEASE_BUFFERS failed to manage buffer pointer during certain recursive calls that could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0195 Remote attackers could trigger buffer overrun attack through invalid DTLS fragments to an OpenSSL DTLS client or server resulting in a denial of service CERT VULNERABILITY NOTE CVE-2014-0591 A crafted query against an NSEC3-signed zone could cause the named process to terminate RESOLVED ISSUES The following issues were reported in previous NIOS releases and resolved in this release The resolved issues are listed by severity For descriptions of the severity levels refer to Severity Levels on page 16 Fixed in 701

ID Severity Summary

NIOS-51535 Major An IPv6 address configured before NIOS 640 was not properly preserved during an upgrade to NIOS 700 which caused an error during product initialization

Fixed in 700

ID Severity Summary

NIOS-50432 Critical Addressed zone journal file size issues that caused DNS service to slow down

NIOS-50295 Critical After a DIW import there were some missing delegations and records in the Grid data set

NIOS-50162 NIOS-50124

Critical Under certain circumstances intermittent DNS service interruptions occurred

ID Severity Summary

NIOS-51186 Major DNS failed to respond to some queries due to new limits exposed by CVE-2014-8500

NIOS-51051 Major DNS service interruptions occurred after changing RPZ records

NIOS 701 Release Notes

copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 14 of 21 400-0579-001 Rev A 1212015

NIOS-50894 Major Updated the Infoblox NIOS Administrator Guide to include information about virtual TFTP root is supported only for file downloads but not for file uploads using TFTP client

NIOS-50784 Major Addressed the following OpenVPN vulnerability CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet

NIOS-50532 Major Addressed the following vulnerabilities CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation

NIOS-50617 NIOS-49810

Major Grid Manager inappropriately marked IPv6 leases as having invalid MAC addresses

NIOS-50575 Major NIOS did not show the root domain for Microsoft servers belonging to two Domains in the same Forest

NIOS-50567 Major DIW failed to handle common CNAME records in different DNS views

NIOS-50453 Major Added information about HA Grid Master providing NTP service through VIP to the Infoblox NIOS Administrator Guide

NIOS-50402 Major Under certain circumstances NIOS returned option 43 in the response when users applied a non-global IPv4 option filter to a DHCP range

NIOS-50250 Major Unable to remove a Grid from the Master Grid

NIOS-50208 Major On some occasions the inheritance state for inherited extensible attributes was displayed as ldquooverriddenrdquo instead of ldquoinheritedrdquo

NIOS-50199 Major Unable to modify a DHCP scope that was synchronized from a Microsoft DHCP failover partner

NIOS-50171 Major Users could not convert a lease to a fixed address without the ldquoNetwork Discoveryrdquo permission which was not required

NIOS-50137 Major VLAN tagging was not functional properly on the HA interface

NIOS-50112 Major High CPU usage on Captive Portal caused by the ldquoomshellrdquo process

NIOS-50081 Major Unable to add the same IPv6 loopback address on other Grid members when the IPv6 address is already configured on the Grid Master

NIOS-50057 Major DHCP service interruptions occurred after an upgrade due to issues related to disabled Grid members in a MAC address filter

NIOS-50052 Major Addressed the following SSL 30 vulnerability CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

NIOS-49962 Major Unable to edit and save Upgrade Schedule

NIOS-49941 Major In a Multi-Grid configuration the Master Grid experienced high swap usage while processing a lot of data

NIOS-49935 Major Under certain circumstances exporting visible data from Grid Manager could fail for a zone

NIOS 701 Release Notes

copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 15 of 21 400-0579-001 Rev A 1212015

NIOS-49934 Major API On rare occasions searching with return_methods could result in incorrect PAPI results

NIOS-49847 Major The appliance returned an error when users tried to disable GSS-TSIG and remove the keys

NIOS-49826 Major Could not start DNS service on the Grid Secondary for a zone that had an external Primary while moving the LAN2 IP address from one member to the other

NIOS-49809 Major In a network template users could not save values for an extensible attribute that was a ldquolistrdquo type

NIOS-49735 Major The status of a Microsoft server was ldquoConnectingrdquo even when synchronization was in progress

NIOS-49505 Major High disk space usage was observed after enabling ldquoCapture DNS Queriesrdquo and ldquoCapture DNS Responsesrdquo

NIOS-49473 Major On rare occasions the Grid Master rebooted and went offline

NIOS-49349 Major The infobloxlog captured bloxTools user password in plain text

NIOS-49339 Major Grid Manager access was denied due to a missing object in the backup file

NIOS-49137 Major Advanced DNS Protection An unexpected HA failover occurred due to a general protection fault

NIOS-48437 Major DNS latency for DNS responses from cache was higher than usual for a duration of a couple seconds

NIOS-48009 Major A schedule upgrade did not function properly if the HA Grid Master had not replicated the schedule to the passive node before the upgrade started

NIOS-47994 Major DHCP service failed to start due to invalid DHCP option spaces defined in the DHCP configuration file

NIOS-50571 Minor Added descriptions about VLAN tag and DSCP support for TE-1400 series appliances to the Infoblox NIOS Administrator Guide

NIOS-50466 Minor DNS service startup took longer than expected due to journal file fragmentation

NIOS-50430 Minor Redefined the description for ldquoinfoblox-deny-rpzrdquo in the Infoblox NIOS Administrator Guide

NIOS-50401 Minor When associating a network with a Microsoft site an error message was displayed in the background instead of inside the editor

NIOS-50366 Minor Updated the CSV Import Reference to include the file format for ldquoresponsepolicyipaddressrdquo objects

NIOS-50267 Minor Unable to perform a discovery for a Microsoft managed subnet

NIOS-49986 Minor Updated IP addresses used in example in the Infoblox NIOS Administrator Guide

NIOS-49838 Minor Could not transfer support bundle using the transfer_supportbundle command

NIOS-49816 Minor The Discoverer field value was truncated in the IP MAP viewer under the Discovered Data tab

NIOS-49787 Minor The appliance logged excessive debugging messages

NIOS 701 Release Notes

copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 16 of 21 400-0579-001 Rev A 1212015

NIOS-48037 Minor Value for the extensible attribute ldquoSiterdquo was not displayed in the Lease Selector when

users tried to connect to an auto-provisioned member

NIOS-50399 Enhance Enhanced the ldquoConvertrdquo button to also appear in the IPAM home page

Severity Levels Severity Description

Critical Core network services are significantly impacted Major Network services are impacted but there is an available workaround Moderate Some loss of secondary services or configuration abilities Minor Minor functional or UI issue Enhance An enhancement to the product

KNOWN GENERAL ISSUES

ID Summary

NIOS-51323 DNS Traffic Control The appliance may return a timeout error while loading the Traffic Management tab in Grid Manager if you have configured health monitoring for a lot of DTC servers

NIOS-51287 Cloud Network Automation Modifying resource records through the cloud API will cause extensible attribute values to be removed

NIOS-51235 In a Multi-Grid configuration converting network connectivity for the Master Grid and its sub Grids to IPv6 only is not supported even though Grid Manager may allow you to do so

NIOS-51134 Infoblox appliances currently do not support HP passive copper cables

NIOS-51054 After you upgrade to NIOS 700 Infoblox recommends that you back up the configuration after you change network connectivity to a different mode (IPv4 IPv6 or IPv4 and IPv6 dual mode) Restoring an old backup by performing a forced restore may prevent some Grid members from rejoining the Grid after the restore

NIOS-50997 In this release the appliance does not automatically create a reverse-mapping zones for 1 for DNS servers that support IPv6

NIOS-50873 When you enable DNS and DHCP services for IPv6 only DDNS updates may not function properly for certain configurations Infoblox recommends that you do not enable DDNS updates in an IPv6-only Grid

NIOS-50859 Creating custom IPv6 NS records and pointing a zone to a particular IPv6 name server is not supported in this release

NIOS-50994 Cloud Network Automation When there is no tenant associated with a network or VM or if a network or VM is created by a cloud adapter but the tenant ID is not specified in the cloud API request the Name or ID column for the tenant or VM is left blank in Grid Manager which implies ldquoNArdquo or not applicable for the specified network or VM

NIOS 701 Release Notes

copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 17 of 21 400-0579-001 Rev A 1212015

NA Reporting When there is too much data being displayed in a graph data can overlap each other and make it difficult for viewing You can expand the graph to view specific data by stretching the graph on display However you will not be able to download the expanded graph in a PDF Workaround Right-click the expanded graph and then select This Frame -gt Print Frame from the drop-down menu to print the graph

NIOS-49238 Network Insight Under certain circumstances deleting networks may not remove the corresponding IP helper addresses from the device configuration

NIOS-49123 Network Insight When scheduling a discovery or port control blackout the scheduled time and time zone will always be standard time No time adjustments are made if the selected time zone is currently in daylight savings time and no adjustments are made when the time zone switches to daylight savings time

NIOS-49107 Network Insight If a recurring port control blackout is scheduled and it includes the current time port control tasks will be delayed during the current blackout period However you may not be warned until the next blackout period If a recurring discovery blackout is scheduled and it includes the current time the Discover Now functionality may not be blocked until the next blackout period

AUGUSTA2-1606

Network Insight Some devices such as the Cisco 3750X may report interfaces (that are not actually functional) as available through SNMP which could cause Port Control jobs on these non-functional interfaces to fail

NIOS-48944 Reporting When there are disconnected data points in the reporting data for reports (such as the DNS Query Rate by Query Type report) that support the stacked area panel type the stacked area that represents the disconnected data in the PDF report may not fill up accordingly and may cause it to look like a line chart when it is actually a stacked area chart Workaround Interpret the information correctly when reading the stacked area charts that contain disconnected data points

NIOS-48912 Network Insight Is a device is not connected to another host through a network the appliance will not be able to detect the Voice VLAN information

NIOS-48897 Network Insight Alcatel Omniswitches can operate in two modesmdashWorking mode and Certified mode Alcatel OmniSwitch 6000 devices must run in Working mode to allow Port Control jobs to work on these devices

NIOS-48704 Reporting When you configure a search for Top Devices Denied an IP Address using Member Network View Network and CIDR as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

NIOS-48560 Network Insight Before joining the Network Data Consolidator to the Grid use the CLI command reset net-automation database to ensure that previously discovered device information is removed from the database

NIOS-48399 You cannot restore the existing deleted resource records from the Recycle Bin after you promote a Grid Master Candidate to the Grid Master

NIOS-48311 On the IB-4010 appliance the maximum resource records allowed in a single signing zone is 800K not 25 of the object limit as in other platforms Exceeding this limit may result in a system restart

NIOS-48135 bloxTools data prior to NIOS 640 cannot be restored on NIOS 611x Workaround Upgrade to NIOS 64x first to get a backup before upgrading to NIOS 611x

NIOS 701 Release Notes

copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 18 of 21 400-0579-001 Rev A 1212015

NIOS-48030 You may not be able to log in to the bloxTools Workflow environment if you download the snapin-workflow file from the bloxTools Community site

NIOS-47959 Through the API and RESTful API users can add records and data without entering values for required extensible attributes Users cannot do the same through Grid Manager

NIOS-46356 An upgrade may fail if you clone reports and searches with duplicate names for the following reports DNS Query Rate by Server DNS Daily Query Rate by Server DNS Daily Peak Hour Query Rate by Server DHCP Device Operating System Trend DHCP Top Device Operating System and Traffic Rate

NIOS-46290 In some scenarios upgrading from NIOS 67x to NIOS 610x on an Infoblox-4030 appliance may require a manual restart to complete the upgrade

NIOS-46102 Advanced DNS Protection You may not be able to join an independent appliance to the Grid if the appliance has threat protection service enabled and only the LAN interface configured Workaround Disable threat protection service on the appliance before joining the Grid or configure the MGMT port and enable VPN on MGMT before joining the offline appliance to the Grid

NIOS-46051 Reporting When you configure a search for Threat Protect Event Count by Severity Trend using Member Category and Rule ID as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

NIOS-45906 Network Insight On rare occasions when there is incomplete inaccurate or misinterpreted data in discovered spanning tree information the appliance may not be able to determine the correct switch to which an end host is attached In this scenario the appliance may display inaccurate discovered data

NIOS-45904 Network Insight In Grid Manager the same end host on different VLANs may appear as duplicates that contain the same VLAN information

NIOS-45872 Content in the bloxHub widget on the Status Dashboard may not be displayed in certain versions of Google Chrome Mozilla FireFox and Microsoft Internet Explorer browsers due to security updates implemented by these browsers Workarounds For Chrome Click the security shield icon next to the URL and select Load unsafe script For FireFox Click the security shield icon next to the URL and select Disable Protection on This Page from the drop-down list For IE Click Show all content in the Only secure content is displayed message bar at the bottom of the page

NIOS-45598 Network Insight When a seed router is specified for an IP address that has already been assigned as a fixed address the IP will still be discovered even if the fixed address is excluded from discovery

NIOS-45233 Reporting When you use Microsoft Internet Explorer 10x and disable ldquoCompatibility Viewrdquo you may not be able to view reports in the Reporting tab Workaround In the Internet Explorer 10 browser go to Tools -gt Compatibility View to enable the feature

NIOS-45220 When you upgrade from NIOS 51r6-12 or earlier releases the Try Snapinstall option may not be available in the bloxTools environment after the upgrade Workaround Stop bloxTools service on the member console connect to the member through the CLI and execute the set bloxtools reset all command Once the reset process is complete restart the bloxTools service to access the Try Snapinstall option

NIOS 701 Release Notes

copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 19 of 21 400-0579-001 Rev A 1212015

VLAN-324 If you have assigned multiple VLANs to the LAN1 or LAN2 interfaces on the appliance you may receive messages about having ldquomultiple interfaces that match the same subnetrdquo during dhcpd process startups or restarts Note that these are not error messages and no actions are required

NIOS-44055 If you use certain versions of Mozilla FireFox to run Grid Manager the auto-detected time zone feature may not function properly even if you have enabled it in your User Profile

NIOS-43957 When you upgrade from NIOS 66x or earlier releases the email address in the SOA resource record that was entered in punycode will be converted into IDN (Internationalized Domain Name) after the upgrade Workaround Convert the IDN back to punycode using the IDN converter utility through Grid Manager

NIOS-43569 You may not be able to view reverse-mapping zones in an internal DNS view Workaround Set the table size to 10 in User Profile log out and then log back in to the system again

NIOS-41136 Reporting When you use certain versions of Mozilla Firefox and Google Chrome browsers on Windows 7 or Linux you may not be able to properly print reports

NIOS-39922 On Trinzic 2200 series appliances it may take up to three minutes for the LOM (Light On Management) LED to stop blinking after you have disabled the LOM feature

NIOS-38870 When you change the member type of an appliance from Infoblox to vNIOS the appliance might display an error message indicating that all network port settings of the vNIOS member must be changed to Automatic Workaround Through the Infoblox API use InfobloxGridMember and the functions lan_port_duplex( ) and lan_port_speed ( ) to change the network port settings for the vNIOS member

NIOS-38579 Reporting If you have a quick filter that includes a filter criterion with report comment equals to a value that NIOS automatically translates to another value the quick filter may not function properly after an upgrade to NIOS 65 or 66 NIOS automatically translates the following ldquoIPAM Utilizationrdquo to ldquoDDI Utilizationrdquo ldquoDNS Zone Statistics per DNS Viewrdquo to ldquoDNS Statistics per DNS Viewrdquo ldquoDNS Zone Statistics per DNS Zonerdquo to ldquoDNS Statistics per Zonerdquo ldquoDNS Member QPS Trendrdquo to ldquoDNS Query Rate by Serverrdquo and ldquoDNS Queries per Second Trendrdquo to ldquoDNS Query Rate by Query Typerdquo Workaround 1 Edit the original report comment values to match the translated values For example if you have entered ldquoIPAM Utilizationrdquo in the comment field of a report change it to ldquoDDI Utilizationrdquo Workaround 2 Edit the quick filter names to match the original comment values For example if you have entered ldquoQF1rdquo as a quick filter name and ldquoIPAM Utilizationrdquo as the report comment change the quick filter name to ldquoIPAM Utilizationrdquo

NIOS-37415 Users cannot execute Trinzic Automation Engine (TAE) if they log out of NetMRI during an active NetMRI session

NIOS-33600 There is an issue with SafeNet HSMs in that configuration changes do not immediately take effect such as when adding a new member to an existing SafeNet HSM Group deleting a client from the HSM or making member changes You can perform a forced restart of services to apply the changes immediately

NIOS-31864 Modifying a zone from a client increments the zonersquos serial number even if the zone contents did not change This causes unnecessary AXFRs to secondary servers and if the zone is served by a Microsoft Server that is managed in read-write mode it causes extra synchronizations as well

NIOS 701 Release Notes

copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 20 of 21 400-0579-001 Rev A 1212015

NIOS-31501 When a Microsoft server is the primary server for a zone and another Microsoft server is hosting the same zone as a stub zone and the NIOS appliance synchronizes DNS data with only one of these zones it will synchronize the zone as an authoritative or stub zone depending on which Microsoft server it synchronizes with first For more information please refer to KB article 17593

NIOS-25064 (45488)

If you configured a member DHCP server to authenticate DHCP clients with a RADIUS authentication server group and RADIUS is disabled (the server group is disabled all RADIUS servers in the group are disabled or the member DHCP server was not assigned an authentication server group) NAC filters with ldquodoes not equalrdquo rules will always match Workaround Do not disable RADIUS

NIOS-21512 (39917)

When you stop the DNS service of an independent appliance with temporary DNS and DHCP licenses Grid Manager displays the Restart Services panel regardless of which function you select

NIOS-21499 (38968)

An admin cannot display DNS views created by other admins during the same browser session To display the DNS views created by other admins you must log out and log in again

NIOS-19853 (31668)

Grid Manager does not display an error when you move a DNS view to a network view that contains a host record that has the same MAC address as a host record in the DNS view that is being moved

NIOS-19144 (30208)

Grid Manager does not sort columns correctly in the IPAM and Network list panels when the columns contain UTF-8 data

NIOS-18163 (27831)

The appliance allows users with read-only permission to A records to view DNSSEC resource records as well

NIOS-17636 (26233)

Syslog messages generated during a TFTP file transfer display the incorrect time zone

NIOS-17513 (26080)

Adding updating or deleting reverse zones could fail due to unsupported PTR records in the root zone

PAPIPASS-39

When you use Mozilla Firefox 16x 17x or Mozilla Firefox Beta 180b3 browser the hidden password in the Add Administrator Wizard of Grid Manager may disappear when you click the Password field after you have confirmed the password This is a known issue when you use Firefox browsers

MME-154 When a NIOS user deletes a Microsoft AD domainrsquos primary zones and subzones NIOS should display a more specific message warning users about the consequences of the operation instead of the general warning message it currently displays

MME-129 When a Microsoft admin creates a delegation on the Microsoft server and the delegation is synchronized to the NIOS appliance the glue A record of the delegation name server is synchronized to the appliance as a manually created record If on the NIOS appliance an admin changes the IP address on the NS record of the delegation name server two A glue records are generated one with the original address one with the new address NIOS retains the original glue A record because itrsquos marked as a manually created record and it can only be changed or deleted either manually on Grid Manager or through the API When synchronization occurs the Microsoft server correctly updates the existing glue A record and does not retain the original Note that NIOS retains the original A record only after the initial update If you update the A record again NIOS just updates the existing record without retaining the original

MME-23 NIOS displays an ldquoInternal Errorrdquo message when you try to apply a quick filter for a range that equals 1 when you display a range in the IPv4 Microsoft Superscopes tab

MME-6 If you add a hostname to the Target field of an SRV record on Grid Manager when the member synchronizes the SRV record to a Microsoft server it adds a new SRV record with the hostname instead of modifying the existing record

NIOS 701 Release Notes

copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 21 of 21 400-0579-001 Rev A 1212015

MSSS-11 (45296)

When you run a discovery on a network served by Microsoft servers and Grid Manager discovers a MAC address that does not match any of the fixed addresses associated with an IP address it reports a conflict and lists the associated fixed address objects in the Related Objects table You cannot select which fixed address to resolve in the Related Objects table You can only resolve the conflict for the first address

VNIOS-36 (41215)

If a virtual NIOS member does not start up due to a license violation Grid Manager displays the status of the vNIOS member as ldquoonlinerunningrdquo even though the member is not online

  • INTRODUCTION
    • Supported Platforms
      • NEW FEATURES
        • NIOS 700
          • CHANGES TO DEFAULT BEHAVIOR
            • NIOS 700
            • NIOS 6x Releases
              • CHANGES TO Infoblox API and RESTful API
                • RESTful API Deprecation and Backward Compatibility Policy
                • NIOS 70x
                • NIOS 6x Releases
                  • UPGRADE GUIDELINES
                    • Upgrading to NIOS 70x
                      • BEFORE YOU INSTALL
                      • ACCESSING GRID MANAGER
                      • ADDRESSED VULNERABILITIES
                      • RESOLVED ISSUES
                        • Fixed in 701
                        • Fixed in 700
                          • KNOWN GENERAL ISSUES

    NIOS 701 Release Notes

    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 2 of 21 400-0579-001 Rev A 1212015

    INTRODUCTION Infoblox NIOS 70x software coupled with Infoblox appliance platforms enables customers to deploy large robust manageable and cost-effective Infoblox Grids This next-generation solution enables distributed delivery of core network servicesmdashincluding DNS DHCP IPAM TFTP and FTPmdashwith the nonstop availability and real-time service management required for todayrsquos 24x7 advanced IP networks and applications Please note the following

    bull NIOS 70x releases are not supported on the following appliances IB-250-A IB-550-A IB-1050-A IB-1550-A IB-1552-A IB-1852-A IB-2000 IB-2000-A IB-VM-250 IB-VM-550 IB-VM-1050 IB-VM-1550 IB-VM-1850 IB-VM-2000 and Trinzic Reporting TR-2000 series appliances You cannot upgrade to NIOS 70x on these appliances See Upgrade Guidelines on page 9 for additional upgrade information

    bull NIOS 70x releases do not support the IF-MAP service You cannot upgrade Infoblox Orchestration Servers to NIOS 70 and later The IF-MAP service is supported in 51r2-IBOS-1 600-IBOS-1 IBOS 210 and later releases For more information visit the Infoblox Support web site at httpssupportinfobloxcom

    Supported Platforms Infoblox NIOS 70x is supported on the following platforms bull NIOS Appliances

    - Infoblox Advanced Appliances PT-1400 PT-2200 and PT-4000 - Network Insight Appliances ND-800 ND-1400 ND-2200 and ND-4000 - Trinzic Appliances TE-100 TE-810 TE-820 TE-1410 TE-1420 TE-2210 TE-2220 and Infoblox-4010 - All Trinzic Rev-1 and Rev-2 appliances (For more information about Trinzic Rev-2 appliances refer to

    KB article 17748 available on the Infoblox Support web site at httpssupportinfobloxcom) - Cloud Network Automation CP-V800 CP-V1400 and CP-V2200 - Trinzic Reporting TR-800 TR-1400 TR-2200 and TR-4000 - Infoblox-4030 DNS Caching Accelerator Appliance

    bull vNIOS for VMware on ESXESXi Servers

    The Infoblox vNIOS on VMware software can run on ESX or ESXi servers that have DAS (Direct Attached Storage) or iSCSI (Internet Small Computer System Interface) or FC (Fibre Channel) SAN (Storage Area Network) attached You can install the vNIOS software package on a host with VMware ESX or ESXi 41 50 51 or 55 installed and configure it as a virtual appliance Note that IB-VM-100 virtual appliances can only run on ESXi 51 servers vSphere vMotion is also supported You can migrate vNIOS virtual appliances from one ESX or ESXi server to another without any service outages The migration preserves the hardware IDs and licenses of the vNIOS virtual appliances VMware Tools is automatically installed for each vNIOS virtual appliance Infoblox supports the control functions in VMware Tools For example through the vSphere client you can shut down the virtual appliance You can deploy certain vNIOS virtual appliances with different hard disk capacity Some vNIOS appliances are not supported as Grid Masters or Grid Master Candidates Note that the IB-VM-800 and IB-VM-1400 virtual appliances are designed for reporting purposes For more information about vNIOS on VMware refer to the Infoblox Installation Guide for vNIOS Software on VMware For information about vNIOS virtual appliances for reporting refer to the Infoblox Installation Guide for vNIOS Reporting Virtual Appliances

    NIOS 701 Release Notes

    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 3 of 21 400-0579-001 Rev A 1212015

    bull vNIOS for Microsoft Server 2008 R2 and 2012 R2 Hyper-V The Infoblox vNIOS virtual appliance is now available for Windows Server 2008 R2 and Windows Server 2012 R2 that have DAS (Direct Attached Storage) Administrators can install vNIOS virtual appliance on Microsoft Windowsreg servers using either Hyper-V Manager or SCVMM A Microsoft Powerscript is available for ease of installation and configuration of the virtual appliance Note that vNIOS for Hyper-V is not recommended as a Grid Master or Grid Master Candidate With this release you can deploy certain vNIOS appliances with a 50 GB 55 GB or 160 GB hard disk You can also deploy the IB-VM-800 and IB-VM-1400 virtual appliances as reporting servers For more information about vNIOS for Hyper-V refer to the Infoblox Installation Guide for vNIOS on Microsoft Hyper-V

    bull vNIOS for Xen Hypervisor The Infoblox vNIOS for Xen is a virtual appliance designed for Citrix XenServer 61 and 62 running Xen hypervisor and for Linux machines running Xenprojectorg 43 hypervisor You can deploy vNIOS for Xen virtual appliances as the Grid Master Grid members or reporting servers depending on the supported models Note that the IB-VM-800 virtual appliances are designed for reporting purposes only For more information about vNIOS for Xen refer to the Infoblox Installation Guide for vNIOS for Xen Hypervisor For information about vNIOS virtual appliances for reporting refer to the Infoblox Installation Guide for vNIOS Reporting Virtual Appliances

    The following table shows available vNIOS virtual appliances and their specifications

    Trinzic Series Virtual Appliances

    Disk (GB)

    of CPU Cores

    Memory Allocation

    Virtual CPU Core Frequency

    vNIOS for VMware

    vNIOS for MS Hyper-V

    vNIOS for Xen

    Supported as Grid Master and Grid Master Candidate (YesNo)

    IB-VM-100 55 1 1 GB 1300 MHz No

    IB-VM-800 (for reporting only

    1 GB daily limit)

    50 2 Range 2 ndash 8 GB

    Default 8 GB

    3000 MHZ No

    IB-VM-800 (for reporting only

    2 GB daily limit)

    50 2 Range 4 ndash 8 GB

    Default 8 GB

    3000 MHZ No

    IB-VM-810 55 2 2 GB 2000 MHz No

    IB-VM-810 160 2 2 GB 2000 MHz Yes

    IB-VM-820 55 2 2 GB 3000 MHz No

    IB-VM-820 160 2 2 GB 3000 MHz Yes

    IB-VM-1400 (for reporting only

    5 GB daily limit)

    55 4 Default 8 GB

    8000 MHz No

    IB-VM-1410 55 4 8 GB 6000 MHz No

    NIOS 701 Release Notes

    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 4 of 21 400-0579-001 Rev A 1212015

    IB-VM-1410 160 4 8 GB 6000 MHz Yes

    IB-VM-1420 160 4 8 GB 8000 MHz Yes

    IB-VM-2210 160 4 12 GB 12000 MHz Yes

    IB-VM-2220 160 4 12 GB 12000 MHz Yes

    Network Insight Virtual Appliances

    Disk (GB)

    of CPU

    Cores

    Memory Allocation

    Virtual CPU Core

    Frequency

    vNIOS for

    VMware

    vNIOS for MS

    Hyper-V

    vNIOS for Xen

    Supported as Grid Master and Grid Master Candidate (YesNo)

    ND-VM-800 160 2 8 GB 3000 MHz No

    ND-VM-1400 160 4 16 GB 8000 MHz No

    ND-VM-2200 160 4 24 GB 24000 MHz No

    Cloud Platform Virtual Appliances

    Disk (GB)

    of CPU

    Cores

    Memory Allocation

    Virtual CPU Core

    Frequency

    vNIOS for

    VMware

    vNIOS for MS

    Hyper-V

    vNIOS for Xen

    Supported as Grid Master and Grid Master Candidate (YesNo)

    CP-V800 160 2 2 GB 2000 MHz No

    CP-V1400 160 4 8 GB 6000 MHz No

    CP-V2200 160 4 12 B 12000 MHz No vNIOS for VMware on Cisco UCS ExpressSRE-V

    The Infoblox vNIOS on VMware software can also run on Cisco SRE-V (Services Ready Engine Virtualization) which is part of the Cisco UCS (Unified Computing System) Express Infoblox has certified running vNIOS for VMware on Cisco SRE-V v15 (for ESXi 41) and v20 (for ESXi 50) Cisco SRE-V enables the VMware vSphere Hypervisor to be provisioned on Cisco SRE 700710 and 900910 Service Modules The Cisco SRE Service Module can reside in the Cisco 2900 and 3900 series ISRs G2 The following table lists the supported vNIOS on VMware virtual appliances on SRE 700710 and SRE 900910

    vNIOS on VMware Virtual Appliances

    Disk (GB) of CPU Cores

    Memory Allocation

    Virtual CPU Core

    Frequency

    Cisco SRE 700710

    Cisco SRE 900910

    IB-VM-810 55 2 2 GB 2000 MHz No Yes

    IB-VM-810 160 2 2 GB 2000 MHz No Yes

    IB-VM-820 55 2 2 GB 3000 MHz No Yes

    IB-VM-820 160 2 2 GB 3000 MHz No Yes

    NIOS 701 Release Notes

    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 5 of 21 400-0579-001 Rev A 1212015

    Note that all vNIOS on VMware virtual appliances running on Cisco SRE-V are not recommended as Grid Masters or Grid Master Candidates The IB-BOB virtual appliance has been renamed to IB-VM-100 For new installation use the 55 GB software image IB-VM-100 only supports configuration as a Grid member

    bull vNIOS on Riverbedreg Steelhead Appliances

    Infoblox has certified the vNIOS on Riverbed software with the following Riverbed Steelhead models and software versions

    Riverbed Models Supported RiOS and EX versions

    1050 2050 5050 RiOS 75 RiOS 80 RiOS 85

    EX560 EX760 EX1160 EX1260 EX 10 (RiOS 7) EX 20 (RiOS 80) EX 25 (RiOS 80) EX 30 (RiOS 850) EX 31 (RiOS 851)

    For additional information refer to the Infoblox Installation Guide for vNIOS Software on Riverbed Steelhead Platforms NOTE You can upgrade a Grid with a Riverbed virtual member to NIOS 7x Ensure that the Riverbed model has 64 bit support

    NEW FEATURES This section lists new features in the 70x releases NIOS 700 Cloud Network Automation The Infoblox Cloud Network Automation solution automates IPAM (IP address management) for physical and virtual network devices on your CMP (Cloud Management Platform) Instead of manually provisioning IP addresses and DNS name spaces for network devices and interfaces you can use Cloud Network Automation to provision and manage IPAM DNS and DHCP within the Grid automatically as VMs (Virtual Machines) are created and destroyed When your Cloud consists of a large number of servers and VMs (virtual machines) that have multiple associated network interfaces manually provisioning and de-provisioning IP addresses and managing DNS and DHCP data can be error-prone and time consuming Utilizing Cloud Network Automation minimizes human errors by streamlining IP Address and DNS record management improves visibility of your cloud networks and maximizes the flexibility efficiency and agility of your cloud environment Cloud Network Automation includes two components the Grid Master that has a Cloud Network Automation license installed and one or more Cloud Platform Appliances The Cloud Network Automation license enables visibility and reporting on cloud tenant network VM IP address and DNS record allocation Cloud Platform Appliances enable processing of API requests from your CMP locally on the same appliances that serve DNS and DHCP to your cloud These appliances provide local survivability and additional scalability of Cloud API requests within your data centers in addition to the visibility provided by the Cloud Network Automation license on the Grid Master DNS Traffic Control Infoblox DNS Traffic Control provides a load balancing solution by adjusting DNS responses based on DNS query source IP server availability and network topology Through DNS Traffic Control you can set up multiple global sites and configure supported objects and load balancing methods to direct responses to the best available servers

    NIOS 701 Release Notes

    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 6 of 21 400-0579-001 Rev A 1212015

    Support for IPv6 Grid

    The Infoblox appliance now supports IPv6 networking configuration in most deployments You can deploy a Grid and configure a Grid Master Grid Member reporting member and an HA pair in one of the following modes IPv4 only IPv6 only or IPv4 and IPv6 dual mode You can also configure the default communication protocol settings using IPv4 or IPv6 In addition services and functionality such as NTP service DNS Firewall and admin notifications now support both IPv4 and IPv6 addresses In addition Grid communication can now support IPv6 only and you can configure an appliance with only IPv6 addresses (no IPv4 addresses are required) Support for Microsoft Sites This release enhances the Microsoft Management solution by adding support for managing Microsoft Active Directory Sites and Subnets on Microsoft servers through Grid Manager DNS Firewall Enhancements This release adds the following enhancements for DNS Firewall

    bull Threat severity levels for RPZ zones bull Threat details in the syslog bull Categorization and filtering for DNS and Advanced DNS Protection syslog messages bull Severity level in the DNS Top RPZ Hits report

    Automated Mitigation of Phantom Domain Attacks This release provides a few CLI commands for mitigating phantom domain attacks in which a flood of queries are sent to resolve non-existent domains When phantom domain attacks happen the recursive server continues to query non-responsive servers spending valuable resources waiting for responses When resources are fully consumed the recursive server may drop legitimate queries causing serious performance issues To mitigate phantom domain attacks you can use the following CLI commands to control queries to non-responsive servers set holddown set fetches_per_server set fetches_per_zone and set recursion_query_timeout For information about these commands refer to the Infoblox CLI Guide DNSSEC Enhancement You can now add multiple cryptographic algorithms that the Grid Master uses when it generates the KSK and ZSK When you add multiple algorithms at the Grid level you can override them at the zone level By default the appliance uses RSASHA1 for both KSK and ZSK You can now add DSA RSAMD5 RSASHA1 RSASHA-256 or RSASHA-512 algorithms Configuring Fixed Addresses without Restarting DHCP Service When you configure or modify a fixed address a DHCP service restart is required by default in order for the new configuration to take effect You can now override this default behavior by enabling the appliance to take immediate action without restarting DHCP service when you configure or modify a fixed address that is outside a DHCP range You can enable this feature at the Grid or member level For Cloud Network Automation deployment this feature is automatically enabled on the Cloud Platform Appliance that has a valid Cloud Platform license installed Ignoring MAC Addresses for New Leases In addition to the UID (unique client identifier) you can now set the DHCP server to ignore the MAC address (hardware address) of a DHCP client when it places a request to the DHCP server for a new lease When you configure the appliance to ignore the MAC addresses of DHCP clients you can specify up to 10 MAC addresses to be ignored

    NIOS 701 Release Notes

    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 7 of 21 400-0579-001 Rev A 1212015

    Name Server Groups for Delegated Zones When you configure a name server group you can now create a set of external name servers as a delegation name server group and assign it to delegated zones Specifying a single delegation name server group instead of configuring multiple name servers individually for delegated zones can significantly reduce configuration efforts Network Insight Assets for Trunk Reports Device discovery now includes in the Asset tab all hosts (physical and virtual) connected to a trunk port Reporting Enhancement This release adds the capability to email reporting search results Infoblox API and RESTful API Enhancement This release adds newly supported objects for the API and RESTful API CHANGES TO DEFAULT BEHAVIOR This section lists changes to default behavior in NIOS 70x and 6x releases NIOS 700

    bull Starting with this release you must have IPv6 addresses for both nodes in an HA pair if one of them has an IPv6 address This was optional in previous releases

    bull In previous releases when you apply a non-global DHCP option filter to a DHCP range the appliance may return option 43 in the response Starting with this release the appliance does not return option 43 in any responses when you apply a non-global DHCP option filter to a range

    NIOS 6x Releases bull In previous releases you could configure DHCP Option 60 (Vendor Class Identifier) match rules

    associated with Microsoft option_space in the Grid or member DHCP properties or DHCP option filters associated with Microsoft option_space Starting with this release these configurations are no longer supported and you cannot configure them

    bull Reporting The ldquoDomain Namerdquo and ldquoMitigation Actionrdquo filters are no longer supported in the Top RPZ Hits by Client report

    bull In previous releases the appliance added grace period to the KSK (Key Signing Key) and ZSK (Zone Signing Key) rollover periods In this release the rollover periods for a particular zone start as soon as it is signed

    bull In previous releases you could assign read-only permission for hosts in a network to restrict admins to only viewing hosts in the specified network In this release assigning read-only permission for hosts in a network does not affect the visibility of hosts in the specified network

    CHANGES TO Infoblox API and RESTful API This section lists changes made to the Infoblox API and RESTful API in NIOS releases For detailed information about the supported methods and objects refer to the latest versions of the Infoblox API Documentation and the Infoblox WAPI Documentation available through the NIOS products and on the Infoblox Support web site The latest available RESTful API version is 20

    NIOS 701 Release Notes

    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 8 of 21 400-0579-001 Rev A 1212015

    RESTful API Deprecation and Backward Compatibility Policy This policy covers the interfaces exposed by the Infoblox RESTful API and the protocol used to communicate with it

    Unless explicitly stated in the release notes previously available RESTful API versions are intended to remain accessible and operative with later versions

    The planned deprecation of a given version of the RESTful API will normally be announced in the release notes at least one year in advance Upon deprecation the announced RESTful API version and all prior versions will no longer be supported in subsequent releases For example if the current RESTful API release is v34 and the release notes contain an announcement of the v15 deprecation v14 and v15 API requests would continue to work with later releases for one year from the announcement date After that some or all requests for these deprecated versions may not work with versions later than v15 API requests adherent to versions later than v15 (v20 for example) would continue to work with subsequent releases Infoblox seeks to avoid any deprecation that has not been announced in advance however product modifications and enhancements may affect specific API requests without a prior announcement Infoblox does not warrant that all API requests will be unaffected by future releases This policy applies to both major and minor versions of the RESTful API Infoblox reserves the right to change this policy NIOS 70x

    bull When executing a RESTful API request from version 20 and later the XML data format has been updated to accommodate tag names (used primarily in extensible attributes) that contain spaces andor invalid XML characters

    NIOS 6x Releases

    bull The RESTful API (WAPI) sample code advises using curl -k3 to access the RESTful API through SSLv3 SSLv3 is no longer supported and the ndashk3 option in curl is no longer supported To correctly use curl to access the RESTful API specify curl -k1 to force the use of TLS

    bull The following changes for keytabs have been made in the Infoblox API

    remove_datakeytab has been removed

    import_datakeytab has been removed

    import_dataupload_keytab has been added

    The API also supports multiple TSIG keys To use a keytab you must upload it and manually assign it to individual members or to DHCP you cannot complete this task in one operation If you have only one keytab you can still use the old gss_tsig members However Infoblox recommends that you switch to the new gss_tsig_keysipv6_gss_tsig_keys members

    bull The following objects have been deprecated in the Infoblox API

    InfobloxGridMSServerDNS (new object InfobloxGridMSServerServerDNS)

    status_last_updated member in InfobloxGridMSServerDNS (new object status_last_updated_ts member in epoc format)

    Though the deprecated objects will continue to function for backward compatibility purposes Infoblox recommends that you use the new objects in your new code

    bull The InfobloxGridAdminUser object password method and the InfobloxGrid object secret method have been modified to adhere to Infoblox security policies

    NIOS 701 Release Notes

    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 9 of 21 400-0579-001 Rev A 1212015

    bull API and RESTful API After upgrading to NIOS 67x all international domain names (IDNs) in punycode are converted to Unicode (in the respective API way of encoding Unicode strings) You can use the dns_[hellip] fields in relevant objects to retrieve read-only IDNs in punycode For more information about IDNs refer to the Infoblox NIOS Administrator Guide For information about API and RESTful API refer to the Infoblox API Documentation and Infoblox RESTful API Documentation

    UPGRADE GUIDELINES Upgrading to NIOS 70x NOTES

    bull You cannot upgrade NIOS 6124 to NIOS 70x You will however be able to upgrade NIOS 6124 and later to NIOS 71x releases when they become available

    bull You cannot upgrade directly from NIOS 5x to NIOS 70x However you can first upgrade to NIOS 66x or later and then to NIOS 70x

    You cannot upgrade to NIOS 70x on the following appliances IB-250-A IB-550-A IB-1050-A IB-1550-A IB-1552-A IB-1852-A IB-2000 IB-2000-A IB-VM-250 IB-VM-550 IB-VM-1050 IB-VM-1550 IB-VM-1850 IB-VM-2000 and Trinzic Reporting TR-2000 series appliances For information about supported platforms see Supported Platforms on page 1 Note the following for IPv6 Grid support

    bull If your Grid Master is configured with an IPv6 VIP all Grid Master Candidates must also include an IPv6 VIP For an HA pair both nodes of the HA pair must have IPv6 addresses for the Grid Master and the Grid Master Candidate

    bull After you upgrade to NIOS 70x Infoblox recommends that you back up the configuration after you change network connectivity to a different mode (IPv4 IPv6 or IPv4 and IPv6 dual mode) Restoring an old backup by performing a forced restore may prevent some Grid members from rejoining the Grid after the restore

    bull IPv6-only configuration does not support the following HSM LCD NAT groups OSPF and BGP

    When you schedule a full upgrade from a previous release to NIOS 70x the following DNSSEC limitations are applicable

    bull You cannot configure new settings that are added to the authoritative zone object while the upgrade is still in progress This restriction is not applicable to future upgrades

    bull When you upgrade you can sign or unsign an authoritative zone only if the Grid Master Candidate and the associated serving members are upgraded This restriction is not applicable to future upgrades

    bull An authoritative zone can have its KSK rollover only if the Grid Master Candidate and all the serving members are upgraded This restriction is not applicable to future upgrades

    bull An authoritative zone can have its ZSK rollover by the daemon only if the Grid Master Candidate and all the serving members are upgraded This restriction is not applicable to future upgrades

    bull You cannot delete keys while the upgrade is still in progress bull You cannot update DNSSEC related parameters at the member level while the upgrade is still in

    progress Example rollover mechanism NSEC3 salt length and iterations and enable or disable automatic KSK rollover

    NIOS 701 Release Notes

    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 10 of 21 400-0579-001 Rev A 1212015

    For Cloud Network Automation bull After upgrading to NIOS 70x you must manually select the Delegated To Cloud Usage

    and Owned By columns in the Data Management tab of Grid Manager to display relevant information This is applicable only if you have installed the Cloud Network Automation license on the Grid Master

    BEFORE YOU INSTALL To ensure that new features and enhancements operate properly and smoothly Infoblox recommends that you evaluate the capacity on your Grid and review the upgrade guidelines before you upgrade from a previous NIOS release Infoblox recommends that administrators planning to perform an upgrade from a previous release create and archive a backup of the Infoblox appliance configuration and data before upgrading You can run an upgrade test before performing the actual upgrade Infoblox recommends that you run the upgrade test so you can resolve any potential data migration issues before the upgrade Following is a list of upgrade and revert paths You can also schedule a full upgrade from these releases 700 6122 and earlier 612x releases 6117 and earlier 611x releases 610201 and 610200 61010 and earlier 610x releases 69201-LD and 69200-LD 690 6813 and earlier 68x releases 678 and earlier 67x releases 6613 and earlier 66x releases Technical Support Infoblox technical support contact information

    Telephone 1-888-463-6259 (toll-free US and Canada) +1-408-625-4200 ext 1

    E-mail supportinfobloxcom

    Web httpssupportinfobloxcom

    GUI Requirements Grid Manager supports the following operating systems and browsers You must install and enable Javascript for Grid Manager to function properly Grid Manager supports only SSL version 3 and TLS version 1 connections Infoblox recommends that you use a computer that has a 2 GHz CPU and at least 1 GB of RAM

    NIOS 701 Release Notes

    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 11 of 21 400-0579-001 Rev A 1212015

    Infoblox supports the following browsers for Grid Manager

    OS Browser Microsoft Windows 80 and 81reg Microsoft Internet Explorerreg 11x 10x

    Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

    Microsoft Windows 7reg Microsoft Internet Explorerreg 11x 10x 9x and 8x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

    Microsoft Windows XPreg (SP2+) Microsoft Internet Explorer 7x and 8x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

    Red Hatreg Enterprise Linuxreg 7x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

    Red Hatreg Enterprise Linuxreg 6x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

    Red Hatreg Enterprise Linux 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

    Applereg Mac OS X 109x Safari 7x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

    Applereg Mac OS X 108x Safari 6x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

    Applereg Mac OS X 107x Safari 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

    Applereg Mac OS X 106x Safari 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

    NOTE Grid Manager fully supports Microsoft Internet Explorerreg 11x and 10x when you enable compatibility view in the browser Features in the Reporting tab may not function properly if you disable compatibility view In the browser go to Tools -gt Compatibility View to enable the feature When viewing Grid Manager set the screen resolution of your monitor as follows

    Minimum resolution 1280 x 768 Recommended resolution 1280 x 1024 or better

    Documentation You can download the Infoblox NIOS Administrator Guide from the appliance From Grid Manager expand the Help panel and then click Documentation -gt Admin Guide Training Training information is available at httpinterviewcentralcomeventsuploadsinfobloxloginhtml

    NIOS 701 Release Notes

    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 12 of 21 400-0579-001 Rev A 1212015

    ACCESSING GRID MANAGER Before you log in to Grid Manager ensure that you have installed your NIOS appliance as described in the installation guide or user guide that shipped with your product and configured it accordingly To log in to Grid Manager

    1 Open an Internet browser window and enter httpsltIPv4 address or hostname of your NIOS appliancegt or https[IPv6 address] of your NIOS appliance The Grid Manager login page appears

    2 Enter your user name and password and then click Login or press Enter The default user name is admin and password is infoblox

    3 Read the Infoblox End-User License Agreement and click I Accept to proceed Grid Manager displays the Dashboard your home page in Grid Manager

    ADDRESSED VULNERABILITIES This section lists security vulnerabilities that were addressed in the past 12 months For vulnerabilities that are not listed in this section refer to Infoblox KB 2899 For additional information about these vulnerabilities including their severities please refer to the National Vulnerability Database (NVD) at httpnvdnistgov The Infoblox Support website at httpssupportinfobloxcom also provides more information including vulnerabilities that do not affect Infoblox appliances CERT VULNERABILITY NOTE CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation CERT VULNERABILITY NOTE CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet CERT VULNERABILITY NOTE CVE-2014-3566 SSL3 is vulnerable to man-in-the-middle-attacks SSL3 is disabled in NIOS and connections must use TLSv1 (which is already used by all supported browsers)

    CERT VULNERABILITY NOTE CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

    CERT VULNERABILITY NOTE CVE-2014-7187 Off-by-one error in the read_token_word function in parsey in GNU BASH through v 43 allowed remote attackers to cause a denial of service (out-of-bounds array access and application crash) or possibly an unspecified impact through deeply nested for loops (also known as the word_lineno issue)

    CERT VULNERABILITY NOTE CVE-2014-7186 The redirection implementation in parsey in GNU BASH through v 43 allowed remote attackers to cause a denial of service (out-of-bounds array access and application crash) or possibly an unspecified impact through the redir_stack issue

    CERT VULNERABILITY NOTE CVE-2014-6271 CVE-3014-6277 CVE-2014-6278 AND CVE-2014-7169 GNU Bash through v 43 processed trailing strings after function definitions in the values of environment variables which allowed remote attackers to execute arbitrary code via a crafted environment (also known as the ShellShock vulnerability)

    NIOS 701 Release Notes

    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 13 of 21 400-0579-001 Rev A 1212015

    CERT VULNERABILITY NOTE CVE-2014-3470 Enabling anonymous ECDH cipher suites on TLS clients could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0224 A specially crafted handshake packet could force the use of weak keying material in the SSLTLS clients allowing a man-in-the-middle (MITM) attack to decrypt and modify traffic between a client and a server CERT VULNERABILITY NOTE CVE-2014-0221 Remote attackers could utilize DTLS hello message in an invalid DTLS handshake to cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0198 Enabling SSL_MODE_RELEASE_BUFFERS failed to manage buffer pointer during certain recursive calls that could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0195 Remote attackers could trigger buffer overrun attack through invalid DTLS fragments to an OpenSSL DTLS client or server resulting in a denial of service CERT VULNERABILITY NOTE CVE-2014-0591 A crafted query against an NSEC3-signed zone could cause the named process to terminate RESOLVED ISSUES The following issues were reported in previous NIOS releases and resolved in this release The resolved issues are listed by severity For descriptions of the severity levels refer to Severity Levels on page 16 Fixed in 701

    ID Severity Summary

    NIOS-51535 Major An IPv6 address configured before NIOS 640 was not properly preserved during an upgrade to NIOS 700 which caused an error during product initialization

    Fixed in 700

    ID Severity Summary

    NIOS-50432 Critical Addressed zone journal file size issues that caused DNS service to slow down

    NIOS-50295 Critical After a DIW import there were some missing delegations and records in the Grid data set

    NIOS-50162 NIOS-50124

    Critical Under certain circumstances intermittent DNS service interruptions occurred

    ID Severity Summary

    NIOS-51186 Major DNS failed to respond to some queries due to new limits exposed by CVE-2014-8500

    NIOS-51051 Major DNS service interruptions occurred after changing RPZ records

    NIOS 701 Release Notes

    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 14 of 21 400-0579-001 Rev A 1212015

    NIOS-50894 Major Updated the Infoblox NIOS Administrator Guide to include information about virtual TFTP root is supported only for file downloads but not for file uploads using TFTP client

    NIOS-50784 Major Addressed the following OpenVPN vulnerability CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet

    NIOS-50532 Major Addressed the following vulnerabilities CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation

    NIOS-50617 NIOS-49810

    Major Grid Manager inappropriately marked IPv6 leases as having invalid MAC addresses

    NIOS-50575 Major NIOS did not show the root domain for Microsoft servers belonging to two Domains in the same Forest

    NIOS-50567 Major DIW failed to handle common CNAME records in different DNS views

    NIOS-50453 Major Added information about HA Grid Master providing NTP service through VIP to the Infoblox NIOS Administrator Guide

    NIOS-50402 Major Under certain circumstances NIOS returned option 43 in the response when users applied a non-global IPv4 option filter to a DHCP range

    NIOS-50250 Major Unable to remove a Grid from the Master Grid

    NIOS-50208 Major On some occasions the inheritance state for inherited extensible attributes was displayed as ldquooverriddenrdquo instead of ldquoinheritedrdquo

    NIOS-50199 Major Unable to modify a DHCP scope that was synchronized from a Microsoft DHCP failover partner

    NIOS-50171 Major Users could not convert a lease to a fixed address without the ldquoNetwork Discoveryrdquo permission which was not required

    NIOS-50137 Major VLAN tagging was not functional properly on the HA interface

    NIOS-50112 Major High CPU usage on Captive Portal caused by the ldquoomshellrdquo process

    NIOS-50081 Major Unable to add the same IPv6 loopback address on other Grid members when the IPv6 address is already configured on the Grid Master

    NIOS-50057 Major DHCP service interruptions occurred after an upgrade due to issues related to disabled Grid members in a MAC address filter

    NIOS-50052 Major Addressed the following SSL 30 vulnerability CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

    NIOS-49962 Major Unable to edit and save Upgrade Schedule

    NIOS-49941 Major In a Multi-Grid configuration the Master Grid experienced high swap usage while processing a lot of data

    NIOS-49935 Major Under certain circumstances exporting visible data from Grid Manager could fail for a zone

    NIOS 701 Release Notes

    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 15 of 21 400-0579-001 Rev A 1212015

    NIOS-49934 Major API On rare occasions searching with return_methods could result in incorrect PAPI results

    NIOS-49847 Major The appliance returned an error when users tried to disable GSS-TSIG and remove the keys

    NIOS-49826 Major Could not start DNS service on the Grid Secondary for a zone that had an external Primary while moving the LAN2 IP address from one member to the other

    NIOS-49809 Major In a network template users could not save values for an extensible attribute that was a ldquolistrdquo type

    NIOS-49735 Major The status of a Microsoft server was ldquoConnectingrdquo even when synchronization was in progress

    NIOS-49505 Major High disk space usage was observed after enabling ldquoCapture DNS Queriesrdquo and ldquoCapture DNS Responsesrdquo

    NIOS-49473 Major On rare occasions the Grid Master rebooted and went offline

    NIOS-49349 Major The infobloxlog captured bloxTools user password in plain text

    NIOS-49339 Major Grid Manager access was denied due to a missing object in the backup file

    NIOS-49137 Major Advanced DNS Protection An unexpected HA failover occurred due to a general protection fault

    NIOS-48437 Major DNS latency for DNS responses from cache was higher than usual for a duration of a couple seconds

    NIOS-48009 Major A schedule upgrade did not function properly if the HA Grid Master had not replicated the schedule to the passive node before the upgrade started

    NIOS-47994 Major DHCP service failed to start due to invalid DHCP option spaces defined in the DHCP configuration file

    NIOS-50571 Minor Added descriptions about VLAN tag and DSCP support for TE-1400 series appliances to the Infoblox NIOS Administrator Guide

    NIOS-50466 Minor DNS service startup took longer than expected due to journal file fragmentation

    NIOS-50430 Minor Redefined the description for ldquoinfoblox-deny-rpzrdquo in the Infoblox NIOS Administrator Guide

    NIOS-50401 Minor When associating a network with a Microsoft site an error message was displayed in the background instead of inside the editor

    NIOS-50366 Minor Updated the CSV Import Reference to include the file format for ldquoresponsepolicyipaddressrdquo objects

    NIOS-50267 Minor Unable to perform a discovery for a Microsoft managed subnet

    NIOS-49986 Minor Updated IP addresses used in example in the Infoblox NIOS Administrator Guide

    NIOS-49838 Minor Could not transfer support bundle using the transfer_supportbundle command

    NIOS-49816 Minor The Discoverer field value was truncated in the IP MAP viewer under the Discovered Data tab

    NIOS-49787 Minor The appliance logged excessive debugging messages

    NIOS 701 Release Notes

    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 16 of 21 400-0579-001 Rev A 1212015

    NIOS-48037 Minor Value for the extensible attribute ldquoSiterdquo was not displayed in the Lease Selector when

    users tried to connect to an auto-provisioned member

    NIOS-50399 Enhance Enhanced the ldquoConvertrdquo button to also appear in the IPAM home page

    Severity Levels Severity Description

    Critical Core network services are significantly impacted Major Network services are impacted but there is an available workaround Moderate Some loss of secondary services or configuration abilities Minor Minor functional or UI issue Enhance An enhancement to the product

    KNOWN GENERAL ISSUES

    ID Summary

    NIOS-51323 DNS Traffic Control The appliance may return a timeout error while loading the Traffic Management tab in Grid Manager if you have configured health monitoring for a lot of DTC servers

    NIOS-51287 Cloud Network Automation Modifying resource records through the cloud API will cause extensible attribute values to be removed

    NIOS-51235 In a Multi-Grid configuration converting network connectivity for the Master Grid and its sub Grids to IPv6 only is not supported even though Grid Manager may allow you to do so

    NIOS-51134 Infoblox appliances currently do not support HP passive copper cables

    NIOS-51054 After you upgrade to NIOS 700 Infoblox recommends that you back up the configuration after you change network connectivity to a different mode (IPv4 IPv6 or IPv4 and IPv6 dual mode) Restoring an old backup by performing a forced restore may prevent some Grid members from rejoining the Grid after the restore

    NIOS-50997 In this release the appliance does not automatically create a reverse-mapping zones for 1 for DNS servers that support IPv6

    NIOS-50873 When you enable DNS and DHCP services for IPv6 only DDNS updates may not function properly for certain configurations Infoblox recommends that you do not enable DDNS updates in an IPv6-only Grid

    NIOS-50859 Creating custom IPv6 NS records and pointing a zone to a particular IPv6 name server is not supported in this release

    NIOS-50994 Cloud Network Automation When there is no tenant associated with a network or VM or if a network or VM is created by a cloud adapter but the tenant ID is not specified in the cloud API request the Name or ID column for the tenant or VM is left blank in Grid Manager which implies ldquoNArdquo or not applicable for the specified network or VM

    NIOS 701 Release Notes

    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 17 of 21 400-0579-001 Rev A 1212015

    NA Reporting When there is too much data being displayed in a graph data can overlap each other and make it difficult for viewing You can expand the graph to view specific data by stretching the graph on display However you will not be able to download the expanded graph in a PDF Workaround Right-click the expanded graph and then select This Frame -gt Print Frame from the drop-down menu to print the graph

    NIOS-49238 Network Insight Under certain circumstances deleting networks may not remove the corresponding IP helper addresses from the device configuration

    NIOS-49123 Network Insight When scheduling a discovery or port control blackout the scheduled time and time zone will always be standard time No time adjustments are made if the selected time zone is currently in daylight savings time and no adjustments are made when the time zone switches to daylight savings time

    NIOS-49107 Network Insight If a recurring port control blackout is scheduled and it includes the current time port control tasks will be delayed during the current blackout period However you may not be warned until the next blackout period If a recurring discovery blackout is scheduled and it includes the current time the Discover Now functionality may not be blocked until the next blackout period

    AUGUSTA2-1606

    Network Insight Some devices such as the Cisco 3750X may report interfaces (that are not actually functional) as available through SNMP which could cause Port Control jobs on these non-functional interfaces to fail

    NIOS-48944 Reporting When there are disconnected data points in the reporting data for reports (such as the DNS Query Rate by Query Type report) that support the stacked area panel type the stacked area that represents the disconnected data in the PDF report may not fill up accordingly and may cause it to look like a line chart when it is actually a stacked area chart Workaround Interpret the information correctly when reading the stacked area charts that contain disconnected data points

    NIOS-48912 Network Insight Is a device is not connected to another host through a network the appliance will not be able to detect the Voice VLAN information

    NIOS-48897 Network Insight Alcatel Omniswitches can operate in two modesmdashWorking mode and Certified mode Alcatel OmniSwitch 6000 devices must run in Working mode to allow Port Control jobs to work on these devices

    NIOS-48704 Reporting When you configure a search for Top Devices Denied an IP Address using Member Network View Network and CIDR as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

    NIOS-48560 Network Insight Before joining the Network Data Consolidator to the Grid use the CLI command reset net-automation database to ensure that previously discovered device information is removed from the database

    NIOS-48399 You cannot restore the existing deleted resource records from the Recycle Bin after you promote a Grid Master Candidate to the Grid Master

    NIOS-48311 On the IB-4010 appliance the maximum resource records allowed in a single signing zone is 800K not 25 of the object limit as in other platforms Exceeding this limit may result in a system restart

    NIOS-48135 bloxTools data prior to NIOS 640 cannot be restored on NIOS 611x Workaround Upgrade to NIOS 64x first to get a backup before upgrading to NIOS 611x

    NIOS 701 Release Notes

    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 18 of 21 400-0579-001 Rev A 1212015

    NIOS-48030 You may not be able to log in to the bloxTools Workflow environment if you download the snapin-workflow file from the bloxTools Community site

    NIOS-47959 Through the API and RESTful API users can add records and data without entering values for required extensible attributes Users cannot do the same through Grid Manager

    NIOS-46356 An upgrade may fail if you clone reports and searches with duplicate names for the following reports DNS Query Rate by Server DNS Daily Query Rate by Server DNS Daily Peak Hour Query Rate by Server DHCP Device Operating System Trend DHCP Top Device Operating System and Traffic Rate

    NIOS-46290 In some scenarios upgrading from NIOS 67x to NIOS 610x on an Infoblox-4030 appliance may require a manual restart to complete the upgrade

    NIOS-46102 Advanced DNS Protection You may not be able to join an independent appliance to the Grid if the appliance has threat protection service enabled and only the LAN interface configured Workaround Disable threat protection service on the appliance before joining the Grid or configure the MGMT port and enable VPN on MGMT before joining the offline appliance to the Grid

    NIOS-46051 Reporting When you configure a search for Threat Protect Event Count by Severity Trend using Member Category and Rule ID as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

    NIOS-45906 Network Insight On rare occasions when there is incomplete inaccurate or misinterpreted data in discovered spanning tree information the appliance may not be able to determine the correct switch to which an end host is attached In this scenario the appliance may display inaccurate discovered data

    NIOS-45904 Network Insight In Grid Manager the same end host on different VLANs may appear as duplicates that contain the same VLAN information

    NIOS-45872 Content in the bloxHub widget on the Status Dashboard may not be displayed in certain versions of Google Chrome Mozilla FireFox and Microsoft Internet Explorer browsers due to security updates implemented by these browsers Workarounds For Chrome Click the security shield icon next to the URL and select Load unsafe script For FireFox Click the security shield icon next to the URL and select Disable Protection on This Page from the drop-down list For IE Click Show all content in the Only secure content is displayed message bar at the bottom of the page

    NIOS-45598 Network Insight When a seed router is specified for an IP address that has already been assigned as a fixed address the IP will still be discovered even if the fixed address is excluded from discovery

    NIOS-45233 Reporting When you use Microsoft Internet Explorer 10x and disable ldquoCompatibility Viewrdquo you may not be able to view reports in the Reporting tab Workaround In the Internet Explorer 10 browser go to Tools -gt Compatibility View to enable the feature

    NIOS-45220 When you upgrade from NIOS 51r6-12 or earlier releases the Try Snapinstall option may not be available in the bloxTools environment after the upgrade Workaround Stop bloxTools service on the member console connect to the member through the CLI and execute the set bloxtools reset all command Once the reset process is complete restart the bloxTools service to access the Try Snapinstall option

    NIOS 701 Release Notes

    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 19 of 21 400-0579-001 Rev A 1212015

    VLAN-324 If you have assigned multiple VLANs to the LAN1 or LAN2 interfaces on the appliance you may receive messages about having ldquomultiple interfaces that match the same subnetrdquo during dhcpd process startups or restarts Note that these are not error messages and no actions are required

    NIOS-44055 If you use certain versions of Mozilla FireFox to run Grid Manager the auto-detected time zone feature may not function properly even if you have enabled it in your User Profile

    NIOS-43957 When you upgrade from NIOS 66x or earlier releases the email address in the SOA resource record that was entered in punycode will be converted into IDN (Internationalized Domain Name) after the upgrade Workaround Convert the IDN back to punycode using the IDN converter utility through Grid Manager

    NIOS-43569 You may not be able to view reverse-mapping zones in an internal DNS view Workaround Set the table size to 10 in User Profile log out and then log back in to the system again

    NIOS-41136 Reporting When you use certain versions of Mozilla Firefox and Google Chrome browsers on Windows 7 or Linux you may not be able to properly print reports

    NIOS-39922 On Trinzic 2200 series appliances it may take up to three minutes for the LOM (Light On Management) LED to stop blinking after you have disabled the LOM feature

    NIOS-38870 When you change the member type of an appliance from Infoblox to vNIOS the appliance might display an error message indicating that all network port settings of the vNIOS member must be changed to Automatic Workaround Through the Infoblox API use InfobloxGridMember and the functions lan_port_duplex( ) and lan_port_speed ( ) to change the network port settings for the vNIOS member

    NIOS-38579 Reporting If you have a quick filter that includes a filter criterion with report comment equals to a value that NIOS automatically translates to another value the quick filter may not function properly after an upgrade to NIOS 65 or 66 NIOS automatically translates the following ldquoIPAM Utilizationrdquo to ldquoDDI Utilizationrdquo ldquoDNS Zone Statistics per DNS Viewrdquo to ldquoDNS Statistics per DNS Viewrdquo ldquoDNS Zone Statistics per DNS Zonerdquo to ldquoDNS Statistics per Zonerdquo ldquoDNS Member QPS Trendrdquo to ldquoDNS Query Rate by Serverrdquo and ldquoDNS Queries per Second Trendrdquo to ldquoDNS Query Rate by Query Typerdquo Workaround 1 Edit the original report comment values to match the translated values For example if you have entered ldquoIPAM Utilizationrdquo in the comment field of a report change it to ldquoDDI Utilizationrdquo Workaround 2 Edit the quick filter names to match the original comment values For example if you have entered ldquoQF1rdquo as a quick filter name and ldquoIPAM Utilizationrdquo as the report comment change the quick filter name to ldquoIPAM Utilizationrdquo

    NIOS-37415 Users cannot execute Trinzic Automation Engine (TAE) if they log out of NetMRI during an active NetMRI session

    NIOS-33600 There is an issue with SafeNet HSMs in that configuration changes do not immediately take effect such as when adding a new member to an existing SafeNet HSM Group deleting a client from the HSM or making member changes You can perform a forced restart of services to apply the changes immediately

    NIOS-31864 Modifying a zone from a client increments the zonersquos serial number even if the zone contents did not change This causes unnecessary AXFRs to secondary servers and if the zone is served by a Microsoft Server that is managed in read-write mode it causes extra synchronizations as well

    NIOS 701 Release Notes

    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 20 of 21 400-0579-001 Rev A 1212015

    NIOS-31501 When a Microsoft server is the primary server for a zone and another Microsoft server is hosting the same zone as a stub zone and the NIOS appliance synchronizes DNS data with only one of these zones it will synchronize the zone as an authoritative or stub zone depending on which Microsoft server it synchronizes with first For more information please refer to KB article 17593

    NIOS-25064 (45488)

    If you configured a member DHCP server to authenticate DHCP clients with a RADIUS authentication server group and RADIUS is disabled (the server group is disabled all RADIUS servers in the group are disabled or the member DHCP server was not assigned an authentication server group) NAC filters with ldquodoes not equalrdquo rules will always match Workaround Do not disable RADIUS

    NIOS-21512 (39917)

    When you stop the DNS service of an independent appliance with temporary DNS and DHCP licenses Grid Manager displays the Restart Services panel regardless of which function you select

    NIOS-21499 (38968)

    An admin cannot display DNS views created by other admins during the same browser session To display the DNS views created by other admins you must log out and log in again

    NIOS-19853 (31668)

    Grid Manager does not display an error when you move a DNS view to a network view that contains a host record that has the same MAC address as a host record in the DNS view that is being moved

    NIOS-19144 (30208)

    Grid Manager does not sort columns correctly in the IPAM and Network list panels when the columns contain UTF-8 data

    NIOS-18163 (27831)

    The appliance allows users with read-only permission to A records to view DNSSEC resource records as well

    NIOS-17636 (26233)

    Syslog messages generated during a TFTP file transfer display the incorrect time zone

    NIOS-17513 (26080)

    Adding updating or deleting reverse zones could fail due to unsupported PTR records in the root zone

    PAPIPASS-39

    When you use Mozilla Firefox 16x 17x or Mozilla Firefox Beta 180b3 browser the hidden password in the Add Administrator Wizard of Grid Manager may disappear when you click the Password field after you have confirmed the password This is a known issue when you use Firefox browsers

    MME-154 When a NIOS user deletes a Microsoft AD domainrsquos primary zones and subzones NIOS should display a more specific message warning users about the consequences of the operation instead of the general warning message it currently displays

    MME-129 When a Microsoft admin creates a delegation on the Microsoft server and the delegation is synchronized to the NIOS appliance the glue A record of the delegation name server is synchronized to the appliance as a manually created record If on the NIOS appliance an admin changes the IP address on the NS record of the delegation name server two A glue records are generated one with the original address one with the new address NIOS retains the original glue A record because itrsquos marked as a manually created record and it can only be changed or deleted either manually on Grid Manager or through the API When synchronization occurs the Microsoft server correctly updates the existing glue A record and does not retain the original Note that NIOS retains the original A record only after the initial update If you update the A record again NIOS just updates the existing record without retaining the original

    MME-23 NIOS displays an ldquoInternal Errorrdquo message when you try to apply a quick filter for a range that equals 1 when you display a range in the IPv4 Microsoft Superscopes tab

    MME-6 If you add a hostname to the Target field of an SRV record on Grid Manager when the member synchronizes the SRV record to a Microsoft server it adds a new SRV record with the hostname instead of modifying the existing record

    NIOS 701 Release Notes

    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 21 of 21 400-0579-001 Rev A 1212015

    MSSS-11 (45296)

    When you run a discovery on a network served by Microsoft servers and Grid Manager discovers a MAC address that does not match any of the fixed addresses associated with an IP address it reports a conflict and lists the associated fixed address objects in the Related Objects table You cannot select which fixed address to resolve in the Related Objects table You can only resolve the conflict for the first address

    VNIOS-36 (41215)

    If a virtual NIOS member does not start up due to a license violation Grid Manager displays the status of the vNIOS member as ldquoonlinerunningrdquo even though the member is not online

    • INTRODUCTION
      • Supported Platforms
        • NEW FEATURES
          • NIOS 700
            • CHANGES TO DEFAULT BEHAVIOR
              • NIOS 700
              • NIOS 6x Releases
                • CHANGES TO Infoblox API and RESTful API
                  • RESTful API Deprecation and Backward Compatibility Policy
                  • NIOS 70x
                  • NIOS 6x Releases
                    • UPGRADE GUIDELINES
                      • Upgrading to NIOS 70x
                        • BEFORE YOU INSTALL
                        • ACCESSING GRID MANAGER
                        • ADDRESSED VULNERABILITIES
                        • RESOLVED ISSUES
                          • Fixed in 701
                          • Fixed in 700
                            • KNOWN GENERAL ISSUES

      NIOS 701 Release Notes

      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 3 of 21 400-0579-001 Rev A 1212015

      bull vNIOS for Microsoft Server 2008 R2 and 2012 R2 Hyper-V The Infoblox vNIOS virtual appliance is now available for Windows Server 2008 R2 and Windows Server 2012 R2 that have DAS (Direct Attached Storage) Administrators can install vNIOS virtual appliance on Microsoft Windowsreg servers using either Hyper-V Manager or SCVMM A Microsoft Powerscript is available for ease of installation and configuration of the virtual appliance Note that vNIOS for Hyper-V is not recommended as a Grid Master or Grid Master Candidate With this release you can deploy certain vNIOS appliances with a 50 GB 55 GB or 160 GB hard disk You can also deploy the IB-VM-800 and IB-VM-1400 virtual appliances as reporting servers For more information about vNIOS for Hyper-V refer to the Infoblox Installation Guide for vNIOS on Microsoft Hyper-V

      bull vNIOS for Xen Hypervisor The Infoblox vNIOS for Xen is a virtual appliance designed for Citrix XenServer 61 and 62 running Xen hypervisor and for Linux machines running Xenprojectorg 43 hypervisor You can deploy vNIOS for Xen virtual appliances as the Grid Master Grid members or reporting servers depending on the supported models Note that the IB-VM-800 virtual appliances are designed for reporting purposes only For more information about vNIOS for Xen refer to the Infoblox Installation Guide for vNIOS for Xen Hypervisor For information about vNIOS virtual appliances for reporting refer to the Infoblox Installation Guide for vNIOS Reporting Virtual Appliances

      The following table shows available vNIOS virtual appliances and their specifications

      Trinzic Series Virtual Appliances

      Disk (GB)

      of CPU Cores

      Memory Allocation

      Virtual CPU Core Frequency

      vNIOS for VMware

      vNIOS for MS Hyper-V

      vNIOS for Xen

      Supported as Grid Master and Grid Master Candidate (YesNo)

      IB-VM-100 55 1 1 GB 1300 MHz No

      IB-VM-800 (for reporting only

      1 GB daily limit)

      50 2 Range 2 ndash 8 GB

      Default 8 GB

      3000 MHZ No

      IB-VM-800 (for reporting only

      2 GB daily limit)

      50 2 Range 4 ndash 8 GB

      Default 8 GB

      3000 MHZ No

      IB-VM-810 55 2 2 GB 2000 MHz No

      IB-VM-810 160 2 2 GB 2000 MHz Yes

      IB-VM-820 55 2 2 GB 3000 MHz No

      IB-VM-820 160 2 2 GB 3000 MHz Yes

      IB-VM-1400 (for reporting only

      5 GB daily limit)

      55 4 Default 8 GB

      8000 MHz No

      IB-VM-1410 55 4 8 GB 6000 MHz No

      NIOS 701 Release Notes

      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 4 of 21 400-0579-001 Rev A 1212015

      IB-VM-1410 160 4 8 GB 6000 MHz Yes

      IB-VM-1420 160 4 8 GB 8000 MHz Yes

      IB-VM-2210 160 4 12 GB 12000 MHz Yes

      IB-VM-2220 160 4 12 GB 12000 MHz Yes

      Network Insight Virtual Appliances

      Disk (GB)

      of CPU

      Cores

      Memory Allocation

      Virtual CPU Core

      Frequency

      vNIOS for

      VMware

      vNIOS for MS

      Hyper-V

      vNIOS for Xen

      Supported as Grid Master and Grid Master Candidate (YesNo)

      ND-VM-800 160 2 8 GB 3000 MHz No

      ND-VM-1400 160 4 16 GB 8000 MHz No

      ND-VM-2200 160 4 24 GB 24000 MHz No

      Cloud Platform Virtual Appliances

      Disk (GB)

      of CPU

      Cores

      Memory Allocation

      Virtual CPU Core

      Frequency

      vNIOS for

      VMware

      vNIOS for MS

      Hyper-V

      vNIOS for Xen

      Supported as Grid Master and Grid Master Candidate (YesNo)

      CP-V800 160 2 2 GB 2000 MHz No

      CP-V1400 160 4 8 GB 6000 MHz No

      CP-V2200 160 4 12 B 12000 MHz No vNIOS for VMware on Cisco UCS ExpressSRE-V

      The Infoblox vNIOS on VMware software can also run on Cisco SRE-V (Services Ready Engine Virtualization) which is part of the Cisco UCS (Unified Computing System) Express Infoblox has certified running vNIOS for VMware on Cisco SRE-V v15 (for ESXi 41) and v20 (for ESXi 50) Cisco SRE-V enables the VMware vSphere Hypervisor to be provisioned on Cisco SRE 700710 and 900910 Service Modules The Cisco SRE Service Module can reside in the Cisco 2900 and 3900 series ISRs G2 The following table lists the supported vNIOS on VMware virtual appliances on SRE 700710 and SRE 900910

      vNIOS on VMware Virtual Appliances

      Disk (GB) of CPU Cores

      Memory Allocation

      Virtual CPU Core

      Frequency

      Cisco SRE 700710

      Cisco SRE 900910

      IB-VM-810 55 2 2 GB 2000 MHz No Yes

      IB-VM-810 160 2 2 GB 2000 MHz No Yes

      IB-VM-820 55 2 2 GB 3000 MHz No Yes

      IB-VM-820 160 2 2 GB 3000 MHz No Yes

      NIOS 701 Release Notes

      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 5 of 21 400-0579-001 Rev A 1212015

      Note that all vNIOS on VMware virtual appliances running on Cisco SRE-V are not recommended as Grid Masters or Grid Master Candidates The IB-BOB virtual appliance has been renamed to IB-VM-100 For new installation use the 55 GB software image IB-VM-100 only supports configuration as a Grid member

      bull vNIOS on Riverbedreg Steelhead Appliances

      Infoblox has certified the vNIOS on Riverbed software with the following Riverbed Steelhead models and software versions

      Riverbed Models Supported RiOS and EX versions

      1050 2050 5050 RiOS 75 RiOS 80 RiOS 85

      EX560 EX760 EX1160 EX1260 EX 10 (RiOS 7) EX 20 (RiOS 80) EX 25 (RiOS 80) EX 30 (RiOS 850) EX 31 (RiOS 851)

      For additional information refer to the Infoblox Installation Guide for vNIOS Software on Riverbed Steelhead Platforms NOTE You can upgrade a Grid with a Riverbed virtual member to NIOS 7x Ensure that the Riverbed model has 64 bit support

      NEW FEATURES This section lists new features in the 70x releases NIOS 700 Cloud Network Automation The Infoblox Cloud Network Automation solution automates IPAM (IP address management) for physical and virtual network devices on your CMP (Cloud Management Platform) Instead of manually provisioning IP addresses and DNS name spaces for network devices and interfaces you can use Cloud Network Automation to provision and manage IPAM DNS and DHCP within the Grid automatically as VMs (Virtual Machines) are created and destroyed When your Cloud consists of a large number of servers and VMs (virtual machines) that have multiple associated network interfaces manually provisioning and de-provisioning IP addresses and managing DNS and DHCP data can be error-prone and time consuming Utilizing Cloud Network Automation minimizes human errors by streamlining IP Address and DNS record management improves visibility of your cloud networks and maximizes the flexibility efficiency and agility of your cloud environment Cloud Network Automation includes two components the Grid Master that has a Cloud Network Automation license installed and one or more Cloud Platform Appliances The Cloud Network Automation license enables visibility and reporting on cloud tenant network VM IP address and DNS record allocation Cloud Platform Appliances enable processing of API requests from your CMP locally on the same appliances that serve DNS and DHCP to your cloud These appliances provide local survivability and additional scalability of Cloud API requests within your data centers in addition to the visibility provided by the Cloud Network Automation license on the Grid Master DNS Traffic Control Infoblox DNS Traffic Control provides a load balancing solution by adjusting DNS responses based on DNS query source IP server availability and network topology Through DNS Traffic Control you can set up multiple global sites and configure supported objects and load balancing methods to direct responses to the best available servers

      NIOS 701 Release Notes

      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 6 of 21 400-0579-001 Rev A 1212015

      Support for IPv6 Grid

      The Infoblox appliance now supports IPv6 networking configuration in most deployments You can deploy a Grid and configure a Grid Master Grid Member reporting member and an HA pair in one of the following modes IPv4 only IPv6 only or IPv4 and IPv6 dual mode You can also configure the default communication protocol settings using IPv4 or IPv6 In addition services and functionality such as NTP service DNS Firewall and admin notifications now support both IPv4 and IPv6 addresses In addition Grid communication can now support IPv6 only and you can configure an appliance with only IPv6 addresses (no IPv4 addresses are required) Support for Microsoft Sites This release enhances the Microsoft Management solution by adding support for managing Microsoft Active Directory Sites and Subnets on Microsoft servers through Grid Manager DNS Firewall Enhancements This release adds the following enhancements for DNS Firewall

      bull Threat severity levels for RPZ zones bull Threat details in the syslog bull Categorization and filtering for DNS and Advanced DNS Protection syslog messages bull Severity level in the DNS Top RPZ Hits report

      Automated Mitigation of Phantom Domain Attacks This release provides a few CLI commands for mitigating phantom domain attacks in which a flood of queries are sent to resolve non-existent domains When phantom domain attacks happen the recursive server continues to query non-responsive servers spending valuable resources waiting for responses When resources are fully consumed the recursive server may drop legitimate queries causing serious performance issues To mitigate phantom domain attacks you can use the following CLI commands to control queries to non-responsive servers set holddown set fetches_per_server set fetches_per_zone and set recursion_query_timeout For information about these commands refer to the Infoblox CLI Guide DNSSEC Enhancement You can now add multiple cryptographic algorithms that the Grid Master uses when it generates the KSK and ZSK When you add multiple algorithms at the Grid level you can override them at the zone level By default the appliance uses RSASHA1 for both KSK and ZSK You can now add DSA RSAMD5 RSASHA1 RSASHA-256 or RSASHA-512 algorithms Configuring Fixed Addresses without Restarting DHCP Service When you configure or modify a fixed address a DHCP service restart is required by default in order for the new configuration to take effect You can now override this default behavior by enabling the appliance to take immediate action without restarting DHCP service when you configure or modify a fixed address that is outside a DHCP range You can enable this feature at the Grid or member level For Cloud Network Automation deployment this feature is automatically enabled on the Cloud Platform Appliance that has a valid Cloud Platform license installed Ignoring MAC Addresses for New Leases In addition to the UID (unique client identifier) you can now set the DHCP server to ignore the MAC address (hardware address) of a DHCP client when it places a request to the DHCP server for a new lease When you configure the appliance to ignore the MAC addresses of DHCP clients you can specify up to 10 MAC addresses to be ignored

      NIOS 701 Release Notes

      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 7 of 21 400-0579-001 Rev A 1212015

      Name Server Groups for Delegated Zones When you configure a name server group you can now create a set of external name servers as a delegation name server group and assign it to delegated zones Specifying a single delegation name server group instead of configuring multiple name servers individually for delegated zones can significantly reduce configuration efforts Network Insight Assets for Trunk Reports Device discovery now includes in the Asset tab all hosts (physical and virtual) connected to a trunk port Reporting Enhancement This release adds the capability to email reporting search results Infoblox API and RESTful API Enhancement This release adds newly supported objects for the API and RESTful API CHANGES TO DEFAULT BEHAVIOR This section lists changes to default behavior in NIOS 70x and 6x releases NIOS 700

      bull Starting with this release you must have IPv6 addresses for both nodes in an HA pair if one of them has an IPv6 address This was optional in previous releases

      bull In previous releases when you apply a non-global DHCP option filter to a DHCP range the appliance may return option 43 in the response Starting with this release the appliance does not return option 43 in any responses when you apply a non-global DHCP option filter to a range

      NIOS 6x Releases bull In previous releases you could configure DHCP Option 60 (Vendor Class Identifier) match rules

      associated with Microsoft option_space in the Grid or member DHCP properties or DHCP option filters associated with Microsoft option_space Starting with this release these configurations are no longer supported and you cannot configure them

      bull Reporting The ldquoDomain Namerdquo and ldquoMitigation Actionrdquo filters are no longer supported in the Top RPZ Hits by Client report

      bull In previous releases the appliance added grace period to the KSK (Key Signing Key) and ZSK (Zone Signing Key) rollover periods In this release the rollover periods for a particular zone start as soon as it is signed

      bull In previous releases you could assign read-only permission for hosts in a network to restrict admins to only viewing hosts in the specified network In this release assigning read-only permission for hosts in a network does not affect the visibility of hosts in the specified network

      CHANGES TO Infoblox API and RESTful API This section lists changes made to the Infoblox API and RESTful API in NIOS releases For detailed information about the supported methods and objects refer to the latest versions of the Infoblox API Documentation and the Infoblox WAPI Documentation available through the NIOS products and on the Infoblox Support web site The latest available RESTful API version is 20

      NIOS 701 Release Notes

      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 8 of 21 400-0579-001 Rev A 1212015

      RESTful API Deprecation and Backward Compatibility Policy This policy covers the interfaces exposed by the Infoblox RESTful API and the protocol used to communicate with it

      Unless explicitly stated in the release notes previously available RESTful API versions are intended to remain accessible and operative with later versions

      The planned deprecation of a given version of the RESTful API will normally be announced in the release notes at least one year in advance Upon deprecation the announced RESTful API version and all prior versions will no longer be supported in subsequent releases For example if the current RESTful API release is v34 and the release notes contain an announcement of the v15 deprecation v14 and v15 API requests would continue to work with later releases for one year from the announcement date After that some or all requests for these deprecated versions may not work with versions later than v15 API requests adherent to versions later than v15 (v20 for example) would continue to work with subsequent releases Infoblox seeks to avoid any deprecation that has not been announced in advance however product modifications and enhancements may affect specific API requests without a prior announcement Infoblox does not warrant that all API requests will be unaffected by future releases This policy applies to both major and minor versions of the RESTful API Infoblox reserves the right to change this policy NIOS 70x

      bull When executing a RESTful API request from version 20 and later the XML data format has been updated to accommodate tag names (used primarily in extensible attributes) that contain spaces andor invalid XML characters

      NIOS 6x Releases

      bull The RESTful API (WAPI) sample code advises using curl -k3 to access the RESTful API through SSLv3 SSLv3 is no longer supported and the ndashk3 option in curl is no longer supported To correctly use curl to access the RESTful API specify curl -k1 to force the use of TLS

      bull The following changes for keytabs have been made in the Infoblox API

      remove_datakeytab has been removed

      import_datakeytab has been removed

      import_dataupload_keytab has been added

      The API also supports multiple TSIG keys To use a keytab you must upload it and manually assign it to individual members or to DHCP you cannot complete this task in one operation If you have only one keytab you can still use the old gss_tsig members However Infoblox recommends that you switch to the new gss_tsig_keysipv6_gss_tsig_keys members

      bull The following objects have been deprecated in the Infoblox API

      InfobloxGridMSServerDNS (new object InfobloxGridMSServerServerDNS)

      status_last_updated member in InfobloxGridMSServerDNS (new object status_last_updated_ts member in epoc format)

      Though the deprecated objects will continue to function for backward compatibility purposes Infoblox recommends that you use the new objects in your new code

      bull The InfobloxGridAdminUser object password method and the InfobloxGrid object secret method have been modified to adhere to Infoblox security policies

      NIOS 701 Release Notes

      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 9 of 21 400-0579-001 Rev A 1212015

      bull API and RESTful API After upgrading to NIOS 67x all international domain names (IDNs) in punycode are converted to Unicode (in the respective API way of encoding Unicode strings) You can use the dns_[hellip] fields in relevant objects to retrieve read-only IDNs in punycode For more information about IDNs refer to the Infoblox NIOS Administrator Guide For information about API and RESTful API refer to the Infoblox API Documentation and Infoblox RESTful API Documentation

      UPGRADE GUIDELINES Upgrading to NIOS 70x NOTES

      bull You cannot upgrade NIOS 6124 to NIOS 70x You will however be able to upgrade NIOS 6124 and later to NIOS 71x releases when they become available

      bull You cannot upgrade directly from NIOS 5x to NIOS 70x However you can first upgrade to NIOS 66x or later and then to NIOS 70x

      You cannot upgrade to NIOS 70x on the following appliances IB-250-A IB-550-A IB-1050-A IB-1550-A IB-1552-A IB-1852-A IB-2000 IB-2000-A IB-VM-250 IB-VM-550 IB-VM-1050 IB-VM-1550 IB-VM-1850 IB-VM-2000 and Trinzic Reporting TR-2000 series appliances For information about supported platforms see Supported Platforms on page 1 Note the following for IPv6 Grid support

      bull If your Grid Master is configured with an IPv6 VIP all Grid Master Candidates must also include an IPv6 VIP For an HA pair both nodes of the HA pair must have IPv6 addresses for the Grid Master and the Grid Master Candidate

      bull After you upgrade to NIOS 70x Infoblox recommends that you back up the configuration after you change network connectivity to a different mode (IPv4 IPv6 or IPv4 and IPv6 dual mode) Restoring an old backup by performing a forced restore may prevent some Grid members from rejoining the Grid after the restore

      bull IPv6-only configuration does not support the following HSM LCD NAT groups OSPF and BGP

      When you schedule a full upgrade from a previous release to NIOS 70x the following DNSSEC limitations are applicable

      bull You cannot configure new settings that are added to the authoritative zone object while the upgrade is still in progress This restriction is not applicable to future upgrades

      bull When you upgrade you can sign or unsign an authoritative zone only if the Grid Master Candidate and the associated serving members are upgraded This restriction is not applicable to future upgrades

      bull An authoritative zone can have its KSK rollover only if the Grid Master Candidate and all the serving members are upgraded This restriction is not applicable to future upgrades

      bull An authoritative zone can have its ZSK rollover by the daemon only if the Grid Master Candidate and all the serving members are upgraded This restriction is not applicable to future upgrades

      bull You cannot delete keys while the upgrade is still in progress bull You cannot update DNSSEC related parameters at the member level while the upgrade is still in

      progress Example rollover mechanism NSEC3 salt length and iterations and enable or disable automatic KSK rollover

      NIOS 701 Release Notes

      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 10 of 21 400-0579-001 Rev A 1212015

      For Cloud Network Automation bull After upgrading to NIOS 70x you must manually select the Delegated To Cloud Usage

      and Owned By columns in the Data Management tab of Grid Manager to display relevant information This is applicable only if you have installed the Cloud Network Automation license on the Grid Master

      BEFORE YOU INSTALL To ensure that new features and enhancements operate properly and smoothly Infoblox recommends that you evaluate the capacity on your Grid and review the upgrade guidelines before you upgrade from a previous NIOS release Infoblox recommends that administrators planning to perform an upgrade from a previous release create and archive a backup of the Infoblox appliance configuration and data before upgrading You can run an upgrade test before performing the actual upgrade Infoblox recommends that you run the upgrade test so you can resolve any potential data migration issues before the upgrade Following is a list of upgrade and revert paths You can also schedule a full upgrade from these releases 700 6122 and earlier 612x releases 6117 and earlier 611x releases 610201 and 610200 61010 and earlier 610x releases 69201-LD and 69200-LD 690 6813 and earlier 68x releases 678 and earlier 67x releases 6613 and earlier 66x releases Technical Support Infoblox technical support contact information

      Telephone 1-888-463-6259 (toll-free US and Canada) +1-408-625-4200 ext 1

      E-mail supportinfobloxcom

      Web httpssupportinfobloxcom

      GUI Requirements Grid Manager supports the following operating systems and browsers You must install and enable Javascript for Grid Manager to function properly Grid Manager supports only SSL version 3 and TLS version 1 connections Infoblox recommends that you use a computer that has a 2 GHz CPU and at least 1 GB of RAM

      NIOS 701 Release Notes

      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 11 of 21 400-0579-001 Rev A 1212015

      Infoblox supports the following browsers for Grid Manager

      OS Browser Microsoft Windows 80 and 81reg Microsoft Internet Explorerreg 11x 10x

      Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

      Microsoft Windows 7reg Microsoft Internet Explorerreg 11x 10x 9x and 8x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

      Microsoft Windows XPreg (SP2+) Microsoft Internet Explorer 7x and 8x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

      Red Hatreg Enterprise Linuxreg 7x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

      Red Hatreg Enterprise Linuxreg 6x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

      Red Hatreg Enterprise Linux 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

      Applereg Mac OS X 109x Safari 7x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

      Applereg Mac OS X 108x Safari 6x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

      Applereg Mac OS X 107x Safari 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

      Applereg Mac OS X 106x Safari 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

      NOTE Grid Manager fully supports Microsoft Internet Explorerreg 11x and 10x when you enable compatibility view in the browser Features in the Reporting tab may not function properly if you disable compatibility view In the browser go to Tools -gt Compatibility View to enable the feature When viewing Grid Manager set the screen resolution of your monitor as follows

      Minimum resolution 1280 x 768 Recommended resolution 1280 x 1024 or better

      Documentation You can download the Infoblox NIOS Administrator Guide from the appliance From Grid Manager expand the Help panel and then click Documentation -gt Admin Guide Training Training information is available at httpinterviewcentralcomeventsuploadsinfobloxloginhtml

      NIOS 701 Release Notes

      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 12 of 21 400-0579-001 Rev A 1212015

      ACCESSING GRID MANAGER Before you log in to Grid Manager ensure that you have installed your NIOS appliance as described in the installation guide or user guide that shipped with your product and configured it accordingly To log in to Grid Manager

      1 Open an Internet browser window and enter httpsltIPv4 address or hostname of your NIOS appliancegt or https[IPv6 address] of your NIOS appliance The Grid Manager login page appears

      2 Enter your user name and password and then click Login or press Enter The default user name is admin and password is infoblox

      3 Read the Infoblox End-User License Agreement and click I Accept to proceed Grid Manager displays the Dashboard your home page in Grid Manager

      ADDRESSED VULNERABILITIES This section lists security vulnerabilities that were addressed in the past 12 months For vulnerabilities that are not listed in this section refer to Infoblox KB 2899 For additional information about these vulnerabilities including their severities please refer to the National Vulnerability Database (NVD) at httpnvdnistgov The Infoblox Support website at httpssupportinfobloxcom also provides more information including vulnerabilities that do not affect Infoblox appliances CERT VULNERABILITY NOTE CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation CERT VULNERABILITY NOTE CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet CERT VULNERABILITY NOTE CVE-2014-3566 SSL3 is vulnerable to man-in-the-middle-attacks SSL3 is disabled in NIOS and connections must use TLSv1 (which is already used by all supported browsers)

      CERT VULNERABILITY NOTE CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

      CERT VULNERABILITY NOTE CVE-2014-7187 Off-by-one error in the read_token_word function in parsey in GNU BASH through v 43 allowed remote attackers to cause a denial of service (out-of-bounds array access and application crash) or possibly an unspecified impact through deeply nested for loops (also known as the word_lineno issue)

      CERT VULNERABILITY NOTE CVE-2014-7186 The redirection implementation in parsey in GNU BASH through v 43 allowed remote attackers to cause a denial of service (out-of-bounds array access and application crash) or possibly an unspecified impact through the redir_stack issue

      CERT VULNERABILITY NOTE CVE-2014-6271 CVE-3014-6277 CVE-2014-6278 AND CVE-2014-7169 GNU Bash through v 43 processed trailing strings after function definitions in the values of environment variables which allowed remote attackers to execute arbitrary code via a crafted environment (also known as the ShellShock vulnerability)

      NIOS 701 Release Notes

      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 13 of 21 400-0579-001 Rev A 1212015

      CERT VULNERABILITY NOTE CVE-2014-3470 Enabling anonymous ECDH cipher suites on TLS clients could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0224 A specially crafted handshake packet could force the use of weak keying material in the SSLTLS clients allowing a man-in-the-middle (MITM) attack to decrypt and modify traffic between a client and a server CERT VULNERABILITY NOTE CVE-2014-0221 Remote attackers could utilize DTLS hello message in an invalid DTLS handshake to cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0198 Enabling SSL_MODE_RELEASE_BUFFERS failed to manage buffer pointer during certain recursive calls that could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0195 Remote attackers could trigger buffer overrun attack through invalid DTLS fragments to an OpenSSL DTLS client or server resulting in a denial of service CERT VULNERABILITY NOTE CVE-2014-0591 A crafted query against an NSEC3-signed zone could cause the named process to terminate RESOLVED ISSUES The following issues were reported in previous NIOS releases and resolved in this release The resolved issues are listed by severity For descriptions of the severity levels refer to Severity Levels on page 16 Fixed in 701

      ID Severity Summary

      NIOS-51535 Major An IPv6 address configured before NIOS 640 was not properly preserved during an upgrade to NIOS 700 which caused an error during product initialization

      Fixed in 700

      ID Severity Summary

      NIOS-50432 Critical Addressed zone journal file size issues that caused DNS service to slow down

      NIOS-50295 Critical After a DIW import there were some missing delegations and records in the Grid data set

      NIOS-50162 NIOS-50124

      Critical Under certain circumstances intermittent DNS service interruptions occurred

      ID Severity Summary

      NIOS-51186 Major DNS failed to respond to some queries due to new limits exposed by CVE-2014-8500

      NIOS-51051 Major DNS service interruptions occurred after changing RPZ records

      NIOS 701 Release Notes

      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 14 of 21 400-0579-001 Rev A 1212015

      NIOS-50894 Major Updated the Infoblox NIOS Administrator Guide to include information about virtual TFTP root is supported only for file downloads but not for file uploads using TFTP client

      NIOS-50784 Major Addressed the following OpenVPN vulnerability CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet

      NIOS-50532 Major Addressed the following vulnerabilities CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation

      NIOS-50617 NIOS-49810

      Major Grid Manager inappropriately marked IPv6 leases as having invalid MAC addresses

      NIOS-50575 Major NIOS did not show the root domain for Microsoft servers belonging to two Domains in the same Forest

      NIOS-50567 Major DIW failed to handle common CNAME records in different DNS views

      NIOS-50453 Major Added information about HA Grid Master providing NTP service through VIP to the Infoblox NIOS Administrator Guide

      NIOS-50402 Major Under certain circumstances NIOS returned option 43 in the response when users applied a non-global IPv4 option filter to a DHCP range

      NIOS-50250 Major Unable to remove a Grid from the Master Grid

      NIOS-50208 Major On some occasions the inheritance state for inherited extensible attributes was displayed as ldquooverriddenrdquo instead of ldquoinheritedrdquo

      NIOS-50199 Major Unable to modify a DHCP scope that was synchronized from a Microsoft DHCP failover partner

      NIOS-50171 Major Users could not convert a lease to a fixed address without the ldquoNetwork Discoveryrdquo permission which was not required

      NIOS-50137 Major VLAN tagging was not functional properly on the HA interface

      NIOS-50112 Major High CPU usage on Captive Portal caused by the ldquoomshellrdquo process

      NIOS-50081 Major Unable to add the same IPv6 loopback address on other Grid members when the IPv6 address is already configured on the Grid Master

      NIOS-50057 Major DHCP service interruptions occurred after an upgrade due to issues related to disabled Grid members in a MAC address filter

      NIOS-50052 Major Addressed the following SSL 30 vulnerability CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

      NIOS-49962 Major Unable to edit and save Upgrade Schedule

      NIOS-49941 Major In a Multi-Grid configuration the Master Grid experienced high swap usage while processing a lot of data

      NIOS-49935 Major Under certain circumstances exporting visible data from Grid Manager could fail for a zone

      NIOS 701 Release Notes

      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 15 of 21 400-0579-001 Rev A 1212015

      NIOS-49934 Major API On rare occasions searching with return_methods could result in incorrect PAPI results

      NIOS-49847 Major The appliance returned an error when users tried to disable GSS-TSIG and remove the keys

      NIOS-49826 Major Could not start DNS service on the Grid Secondary for a zone that had an external Primary while moving the LAN2 IP address from one member to the other

      NIOS-49809 Major In a network template users could not save values for an extensible attribute that was a ldquolistrdquo type

      NIOS-49735 Major The status of a Microsoft server was ldquoConnectingrdquo even when synchronization was in progress

      NIOS-49505 Major High disk space usage was observed after enabling ldquoCapture DNS Queriesrdquo and ldquoCapture DNS Responsesrdquo

      NIOS-49473 Major On rare occasions the Grid Master rebooted and went offline

      NIOS-49349 Major The infobloxlog captured bloxTools user password in plain text

      NIOS-49339 Major Grid Manager access was denied due to a missing object in the backup file

      NIOS-49137 Major Advanced DNS Protection An unexpected HA failover occurred due to a general protection fault

      NIOS-48437 Major DNS latency for DNS responses from cache was higher than usual for a duration of a couple seconds

      NIOS-48009 Major A schedule upgrade did not function properly if the HA Grid Master had not replicated the schedule to the passive node before the upgrade started

      NIOS-47994 Major DHCP service failed to start due to invalid DHCP option spaces defined in the DHCP configuration file

      NIOS-50571 Minor Added descriptions about VLAN tag and DSCP support for TE-1400 series appliances to the Infoblox NIOS Administrator Guide

      NIOS-50466 Minor DNS service startup took longer than expected due to journal file fragmentation

      NIOS-50430 Minor Redefined the description for ldquoinfoblox-deny-rpzrdquo in the Infoblox NIOS Administrator Guide

      NIOS-50401 Minor When associating a network with a Microsoft site an error message was displayed in the background instead of inside the editor

      NIOS-50366 Minor Updated the CSV Import Reference to include the file format for ldquoresponsepolicyipaddressrdquo objects

      NIOS-50267 Minor Unable to perform a discovery for a Microsoft managed subnet

      NIOS-49986 Minor Updated IP addresses used in example in the Infoblox NIOS Administrator Guide

      NIOS-49838 Minor Could not transfer support bundle using the transfer_supportbundle command

      NIOS-49816 Minor The Discoverer field value was truncated in the IP MAP viewer under the Discovered Data tab

      NIOS-49787 Minor The appliance logged excessive debugging messages

      NIOS 701 Release Notes

      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 16 of 21 400-0579-001 Rev A 1212015

      NIOS-48037 Minor Value for the extensible attribute ldquoSiterdquo was not displayed in the Lease Selector when

      users tried to connect to an auto-provisioned member

      NIOS-50399 Enhance Enhanced the ldquoConvertrdquo button to also appear in the IPAM home page

      Severity Levels Severity Description

      Critical Core network services are significantly impacted Major Network services are impacted but there is an available workaround Moderate Some loss of secondary services or configuration abilities Minor Minor functional or UI issue Enhance An enhancement to the product

      KNOWN GENERAL ISSUES

      ID Summary

      NIOS-51323 DNS Traffic Control The appliance may return a timeout error while loading the Traffic Management tab in Grid Manager if you have configured health monitoring for a lot of DTC servers

      NIOS-51287 Cloud Network Automation Modifying resource records through the cloud API will cause extensible attribute values to be removed

      NIOS-51235 In a Multi-Grid configuration converting network connectivity for the Master Grid and its sub Grids to IPv6 only is not supported even though Grid Manager may allow you to do so

      NIOS-51134 Infoblox appliances currently do not support HP passive copper cables

      NIOS-51054 After you upgrade to NIOS 700 Infoblox recommends that you back up the configuration after you change network connectivity to a different mode (IPv4 IPv6 or IPv4 and IPv6 dual mode) Restoring an old backup by performing a forced restore may prevent some Grid members from rejoining the Grid after the restore

      NIOS-50997 In this release the appliance does not automatically create a reverse-mapping zones for 1 for DNS servers that support IPv6

      NIOS-50873 When you enable DNS and DHCP services for IPv6 only DDNS updates may not function properly for certain configurations Infoblox recommends that you do not enable DDNS updates in an IPv6-only Grid

      NIOS-50859 Creating custom IPv6 NS records and pointing a zone to a particular IPv6 name server is not supported in this release

      NIOS-50994 Cloud Network Automation When there is no tenant associated with a network or VM or if a network or VM is created by a cloud adapter but the tenant ID is not specified in the cloud API request the Name or ID column for the tenant or VM is left blank in Grid Manager which implies ldquoNArdquo or not applicable for the specified network or VM

      NIOS 701 Release Notes

      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 17 of 21 400-0579-001 Rev A 1212015

      NA Reporting When there is too much data being displayed in a graph data can overlap each other and make it difficult for viewing You can expand the graph to view specific data by stretching the graph on display However you will not be able to download the expanded graph in a PDF Workaround Right-click the expanded graph and then select This Frame -gt Print Frame from the drop-down menu to print the graph

      NIOS-49238 Network Insight Under certain circumstances deleting networks may not remove the corresponding IP helper addresses from the device configuration

      NIOS-49123 Network Insight When scheduling a discovery or port control blackout the scheduled time and time zone will always be standard time No time adjustments are made if the selected time zone is currently in daylight savings time and no adjustments are made when the time zone switches to daylight savings time

      NIOS-49107 Network Insight If a recurring port control blackout is scheduled and it includes the current time port control tasks will be delayed during the current blackout period However you may not be warned until the next blackout period If a recurring discovery blackout is scheduled and it includes the current time the Discover Now functionality may not be blocked until the next blackout period

      AUGUSTA2-1606

      Network Insight Some devices such as the Cisco 3750X may report interfaces (that are not actually functional) as available through SNMP which could cause Port Control jobs on these non-functional interfaces to fail

      NIOS-48944 Reporting When there are disconnected data points in the reporting data for reports (such as the DNS Query Rate by Query Type report) that support the stacked area panel type the stacked area that represents the disconnected data in the PDF report may not fill up accordingly and may cause it to look like a line chart when it is actually a stacked area chart Workaround Interpret the information correctly when reading the stacked area charts that contain disconnected data points

      NIOS-48912 Network Insight Is a device is not connected to another host through a network the appliance will not be able to detect the Voice VLAN information

      NIOS-48897 Network Insight Alcatel Omniswitches can operate in two modesmdashWorking mode and Certified mode Alcatel OmniSwitch 6000 devices must run in Working mode to allow Port Control jobs to work on these devices

      NIOS-48704 Reporting When you configure a search for Top Devices Denied an IP Address using Member Network View Network and CIDR as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

      NIOS-48560 Network Insight Before joining the Network Data Consolidator to the Grid use the CLI command reset net-automation database to ensure that previously discovered device information is removed from the database

      NIOS-48399 You cannot restore the existing deleted resource records from the Recycle Bin after you promote a Grid Master Candidate to the Grid Master

      NIOS-48311 On the IB-4010 appliance the maximum resource records allowed in a single signing zone is 800K not 25 of the object limit as in other platforms Exceeding this limit may result in a system restart

      NIOS-48135 bloxTools data prior to NIOS 640 cannot be restored on NIOS 611x Workaround Upgrade to NIOS 64x first to get a backup before upgrading to NIOS 611x

      NIOS 701 Release Notes

      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 18 of 21 400-0579-001 Rev A 1212015

      NIOS-48030 You may not be able to log in to the bloxTools Workflow environment if you download the snapin-workflow file from the bloxTools Community site

      NIOS-47959 Through the API and RESTful API users can add records and data without entering values for required extensible attributes Users cannot do the same through Grid Manager

      NIOS-46356 An upgrade may fail if you clone reports and searches with duplicate names for the following reports DNS Query Rate by Server DNS Daily Query Rate by Server DNS Daily Peak Hour Query Rate by Server DHCP Device Operating System Trend DHCP Top Device Operating System and Traffic Rate

      NIOS-46290 In some scenarios upgrading from NIOS 67x to NIOS 610x on an Infoblox-4030 appliance may require a manual restart to complete the upgrade

      NIOS-46102 Advanced DNS Protection You may not be able to join an independent appliance to the Grid if the appliance has threat protection service enabled and only the LAN interface configured Workaround Disable threat protection service on the appliance before joining the Grid or configure the MGMT port and enable VPN on MGMT before joining the offline appliance to the Grid

      NIOS-46051 Reporting When you configure a search for Threat Protect Event Count by Severity Trend using Member Category and Rule ID as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

      NIOS-45906 Network Insight On rare occasions when there is incomplete inaccurate or misinterpreted data in discovered spanning tree information the appliance may not be able to determine the correct switch to which an end host is attached In this scenario the appliance may display inaccurate discovered data

      NIOS-45904 Network Insight In Grid Manager the same end host on different VLANs may appear as duplicates that contain the same VLAN information

      NIOS-45872 Content in the bloxHub widget on the Status Dashboard may not be displayed in certain versions of Google Chrome Mozilla FireFox and Microsoft Internet Explorer browsers due to security updates implemented by these browsers Workarounds For Chrome Click the security shield icon next to the URL and select Load unsafe script For FireFox Click the security shield icon next to the URL and select Disable Protection on This Page from the drop-down list For IE Click Show all content in the Only secure content is displayed message bar at the bottom of the page

      NIOS-45598 Network Insight When a seed router is specified for an IP address that has already been assigned as a fixed address the IP will still be discovered even if the fixed address is excluded from discovery

      NIOS-45233 Reporting When you use Microsoft Internet Explorer 10x and disable ldquoCompatibility Viewrdquo you may not be able to view reports in the Reporting tab Workaround In the Internet Explorer 10 browser go to Tools -gt Compatibility View to enable the feature

      NIOS-45220 When you upgrade from NIOS 51r6-12 or earlier releases the Try Snapinstall option may not be available in the bloxTools environment after the upgrade Workaround Stop bloxTools service on the member console connect to the member through the CLI and execute the set bloxtools reset all command Once the reset process is complete restart the bloxTools service to access the Try Snapinstall option

      NIOS 701 Release Notes

      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 19 of 21 400-0579-001 Rev A 1212015

      VLAN-324 If you have assigned multiple VLANs to the LAN1 or LAN2 interfaces on the appliance you may receive messages about having ldquomultiple interfaces that match the same subnetrdquo during dhcpd process startups or restarts Note that these are not error messages and no actions are required

      NIOS-44055 If you use certain versions of Mozilla FireFox to run Grid Manager the auto-detected time zone feature may not function properly even if you have enabled it in your User Profile

      NIOS-43957 When you upgrade from NIOS 66x or earlier releases the email address in the SOA resource record that was entered in punycode will be converted into IDN (Internationalized Domain Name) after the upgrade Workaround Convert the IDN back to punycode using the IDN converter utility through Grid Manager

      NIOS-43569 You may not be able to view reverse-mapping zones in an internal DNS view Workaround Set the table size to 10 in User Profile log out and then log back in to the system again

      NIOS-41136 Reporting When you use certain versions of Mozilla Firefox and Google Chrome browsers on Windows 7 or Linux you may not be able to properly print reports

      NIOS-39922 On Trinzic 2200 series appliances it may take up to three minutes for the LOM (Light On Management) LED to stop blinking after you have disabled the LOM feature

      NIOS-38870 When you change the member type of an appliance from Infoblox to vNIOS the appliance might display an error message indicating that all network port settings of the vNIOS member must be changed to Automatic Workaround Through the Infoblox API use InfobloxGridMember and the functions lan_port_duplex( ) and lan_port_speed ( ) to change the network port settings for the vNIOS member

      NIOS-38579 Reporting If you have a quick filter that includes a filter criterion with report comment equals to a value that NIOS automatically translates to another value the quick filter may not function properly after an upgrade to NIOS 65 or 66 NIOS automatically translates the following ldquoIPAM Utilizationrdquo to ldquoDDI Utilizationrdquo ldquoDNS Zone Statistics per DNS Viewrdquo to ldquoDNS Statistics per DNS Viewrdquo ldquoDNS Zone Statistics per DNS Zonerdquo to ldquoDNS Statistics per Zonerdquo ldquoDNS Member QPS Trendrdquo to ldquoDNS Query Rate by Serverrdquo and ldquoDNS Queries per Second Trendrdquo to ldquoDNS Query Rate by Query Typerdquo Workaround 1 Edit the original report comment values to match the translated values For example if you have entered ldquoIPAM Utilizationrdquo in the comment field of a report change it to ldquoDDI Utilizationrdquo Workaround 2 Edit the quick filter names to match the original comment values For example if you have entered ldquoQF1rdquo as a quick filter name and ldquoIPAM Utilizationrdquo as the report comment change the quick filter name to ldquoIPAM Utilizationrdquo

      NIOS-37415 Users cannot execute Trinzic Automation Engine (TAE) if they log out of NetMRI during an active NetMRI session

      NIOS-33600 There is an issue with SafeNet HSMs in that configuration changes do not immediately take effect such as when adding a new member to an existing SafeNet HSM Group deleting a client from the HSM or making member changes You can perform a forced restart of services to apply the changes immediately

      NIOS-31864 Modifying a zone from a client increments the zonersquos serial number even if the zone contents did not change This causes unnecessary AXFRs to secondary servers and if the zone is served by a Microsoft Server that is managed in read-write mode it causes extra synchronizations as well

      NIOS 701 Release Notes

      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 20 of 21 400-0579-001 Rev A 1212015

      NIOS-31501 When a Microsoft server is the primary server for a zone and another Microsoft server is hosting the same zone as a stub zone and the NIOS appliance synchronizes DNS data with only one of these zones it will synchronize the zone as an authoritative or stub zone depending on which Microsoft server it synchronizes with first For more information please refer to KB article 17593

      NIOS-25064 (45488)

      If you configured a member DHCP server to authenticate DHCP clients with a RADIUS authentication server group and RADIUS is disabled (the server group is disabled all RADIUS servers in the group are disabled or the member DHCP server was not assigned an authentication server group) NAC filters with ldquodoes not equalrdquo rules will always match Workaround Do not disable RADIUS

      NIOS-21512 (39917)

      When you stop the DNS service of an independent appliance with temporary DNS and DHCP licenses Grid Manager displays the Restart Services panel regardless of which function you select

      NIOS-21499 (38968)

      An admin cannot display DNS views created by other admins during the same browser session To display the DNS views created by other admins you must log out and log in again

      NIOS-19853 (31668)

      Grid Manager does not display an error when you move a DNS view to a network view that contains a host record that has the same MAC address as a host record in the DNS view that is being moved

      NIOS-19144 (30208)

      Grid Manager does not sort columns correctly in the IPAM and Network list panels when the columns contain UTF-8 data

      NIOS-18163 (27831)

      The appliance allows users with read-only permission to A records to view DNSSEC resource records as well

      NIOS-17636 (26233)

      Syslog messages generated during a TFTP file transfer display the incorrect time zone

      NIOS-17513 (26080)

      Adding updating or deleting reverse zones could fail due to unsupported PTR records in the root zone

      PAPIPASS-39

      When you use Mozilla Firefox 16x 17x or Mozilla Firefox Beta 180b3 browser the hidden password in the Add Administrator Wizard of Grid Manager may disappear when you click the Password field after you have confirmed the password This is a known issue when you use Firefox browsers

      MME-154 When a NIOS user deletes a Microsoft AD domainrsquos primary zones and subzones NIOS should display a more specific message warning users about the consequences of the operation instead of the general warning message it currently displays

      MME-129 When a Microsoft admin creates a delegation on the Microsoft server and the delegation is synchronized to the NIOS appliance the glue A record of the delegation name server is synchronized to the appliance as a manually created record If on the NIOS appliance an admin changes the IP address on the NS record of the delegation name server two A glue records are generated one with the original address one with the new address NIOS retains the original glue A record because itrsquos marked as a manually created record and it can only be changed or deleted either manually on Grid Manager or through the API When synchronization occurs the Microsoft server correctly updates the existing glue A record and does not retain the original Note that NIOS retains the original A record only after the initial update If you update the A record again NIOS just updates the existing record without retaining the original

      MME-23 NIOS displays an ldquoInternal Errorrdquo message when you try to apply a quick filter for a range that equals 1 when you display a range in the IPv4 Microsoft Superscopes tab

      MME-6 If you add a hostname to the Target field of an SRV record on Grid Manager when the member synchronizes the SRV record to a Microsoft server it adds a new SRV record with the hostname instead of modifying the existing record

      NIOS 701 Release Notes

      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 21 of 21 400-0579-001 Rev A 1212015

      MSSS-11 (45296)

      When you run a discovery on a network served by Microsoft servers and Grid Manager discovers a MAC address that does not match any of the fixed addresses associated with an IP address it reports a conflict and lists the associated fixed address objects in the Related Objects table You cannot select which fixed address to resolve in the Related Objects table You can only resolve the conflict for the first address

      VNIOS-36 (41215)

      If a virtual NIOS member does not start up due to a license violation Grid Manager displays the status of the vNIOS member as ldquoonlinerunningrdquo even though the member is not online

      • INTRODUCTION
        • Supported Platforms
          • NEW FEATURES
            • NIOS 700
              • CHANGES TO DEFAULT BEHAVIOR
                • NIOS 700
                • NIOS 6x Releases
                  • CHANGES TO Infoblox API and RESTful API
                    • RESTful API Deprecation and Backward Compatibility Policy
                    • NIOS 70x
                    • NIOS 6x Releases
                      • UPGRADE GUIDELINES
                        • Upgrading to NIOS 70x
                          • BEFORE YOU INSTALL
                          • ACCESSING GRID MANAGER
                          • ADDRESSED VULNERABILITIES
                          • RESOLVED ISSUES
                            • Fixed in 701
                            • Fixed in 700
                              • KNOWN GENERAL ISSUES

        NIOS 701 Release Notes

        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 4 of 21 400-0579-001 Rev A 1212015

        IB-VM-1410 160 4 8 GB 6000 MHz Yes

        IB-VM-1420 160 4 8 GB 8000 MHz Yes

        IB-VM-2210 160 4 12 GB 12000 MHz Yes

        IB-VM-2220 160 4 12 GB 12000 MHz Yes

        Network Insight Virtual Appliances

        Disk (GB)

        of CPU

        Cores

        Memory Allocation

        Virtual CPU Core

        Frequency

        vNIOS for

        VMware

        vNIOS for MS

        Hyper-V

        vNIOS for Xen

        Supported as Grid Master and Grid Master Candidate (YesNo)

        ND-VM-800 160 2 8 GB 3000 MHz No

        ND-VM-1400 160 4 16 GB 8000 MHz No

        ND-VM-2200 160 4 24 GB 24000 MHz No

        Cloud Platform Virtual Appliances

        Disk (GB)

        of CPU

        Cores

        Memory Allocation

        Virtual CPU Core

        Frequency

        vNIOS for

        VMware

        vNIOS for MS

        Hyper-V

        vNIOS for Xen

        Supported as Grid Master and Grid Master Candidate (YesNo)

        CP-V800 160 2 2 GB 2000 MHz No

        CP-V1400 160 4 8 GB 6000 MHz No

        CP-V2200 160 4 12 B 12000 MHz No vNIOS for VMware on Cisco UCS ExpressSRE-V

        The Infoblox vNIOS on VMware software can also run on Cisco SRE-V (Services Ready Engine Virtualization) which is part of the Cisco UCS (Unified Computing System) Express Infoblox has certified running vNIOS for VMware on Cisco SRE-V v15 (for ESXi 41) and v20 (for ESXi 50) Cisco SRE-V enables the VMware vSphere Hypervisor to be provisioned on Cisco SRE 700710 and 900910 Service Modules The Cisco SRE Service Module can reside in the Cisco 2900 and 3900 series ISRs G2 The following table lists the supported vNIOS on VMware virtual appliances on SRE 700710 and SRE 900910

        vNIOS on VMware Virtual Appliances

        Disk (GB) of CPU Cores

        Memory Allocation

        Virtual CPU Core

        Frequency

        Cisco SRE 700710

        Cisco SRE 900910

        IB-VM-810 55 2 2 GB 2000 MHz No Yes

        IB-VM-810 160 2 2 GB 2000 MHz No Yes

        IB-VM-820 55 2 2 GB 3000 MHz No Yes

        IB-VM-820 160 2 2 GB 3000 MHz No Yes

        NIOS 701 Release Notes

        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 5 of 21 400-0579-001 Rev A 1212015

        Note that all vNIOS on VMware virtual appliances running on Cisco SRE-V are not recommended as Grid Masters or Grid Master Candidates The IB-BOB virtual appliance has been renamed to IB-VM-100 For new installation use the 55 GB software image IB-VM-100 only supports configuration as a Grid member

        bull vNIOS on Riverbedreg Steelhead Appliances

        Infoblox has certified the vNIOS on Riverbed software with the following Riverbed Steelhead models and software versions

        Riverbed Models Supported RiOS and EX versions

        1050 2050 5050 RiOS 75 RiOS 80 RiOS 85

        EX560 EX760 EX1160 EX1260 EX 10 (RiOS 7) EX 20 (RiOS 80) EX 25 (RiOS 80) EX 30 (RiOS 850) EX 31 (RiOS 851)

        For additional information refer to the Infoblox Installation Guide for vNIOS Software on Riverbed Steelhead Platforms NOTE You can upgrade a Grid with a Riverbed virtual member to NIOS 7x Ensure that the Riverbed model has 64 bit support

        NEW FEATURES This section lists new features in the 70x releases NIOS 700 Cloud Network Automation The Infoblox Cloud Network Automation solution automates IPAM (IP address management) for physical and virtual network devices on your CMP (Cloud Management Platform) Instead of manually provisioning IP addresses and DNS name spaces for network devices and interfaces you can use Cloud Network Automation to provision and manage IPAM DNS and DHCP within the Grid automatically as VMs (Virtual Machines) are created and destroyed When your Cloud consists of a large number of servers and VMs (virtual machines) that have multiple associated network interfaces manually provisioning and de-provisioning IP addresses and managing DNS and DHCP data can be error-prone and time consuming Utilizing Cloud Network Automation minimizes human errors by streamlining IP Address and DNS record management improves visibility of your cloud networks and maximizes the flexibility efficiency and agility of your cloud environment Cloud Network Automation includes two components the Grid Master that has a Cloud Network Automation license installed and one or more Cloud Platform Appliances The Cloud Network Automation license enables visibility and reporting on cloud tenant network VM IP address and DNS record allocation Cloud Platform Appliances enable processing of API requests from your CMP locally on the same appliances that serve DNS and DHCP to your cloud These appliances provide local survivability and additional scalability of Cloud API requests within your data centers in addition to the visibility provided by the Cloud Network Automation license on the Grid Master DNS Traffic Control Infoblox DNS Traffic Control provides a load balancing solution by adjusting DNS responses based on DNS query source IP server availability and network topology Through DNS Traffic Control you can set up multiple global sites and configure supported objects and load balancing methods to direct responses to the best available servers

        NIOS 701 Release Notes

        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 6 of 21 400-0579-001 Rev A 1212015

        Support for IPv6 Grid

        The Infoblox appliance now supports IPv6 networking configuration in most deployments You can deploy a Grid and configure a Grid Master Grid Member reporting member and an HA pair in one of the following modes IPv4 only IPv6 only or IPv4 and IPv6 dual mode You can also configure the default communication protocol settings using IPv4 or IPv6 In addition services and functionality such as NTP service DNS Firewall and admin notifications now support both IPv4 and IPv6 addresses In addition Grid communication can now support IPv6 only and you can configure an appliance with only IPv6 addresses (no IPv4 addresses are required) Support for Microsoft Sites This release enhances the Microsoft Management solution by adding support for managing Microsoft Active Directory Sites and Subnets on Microsoft servers through Grid Manager DNS Firewall Enhancements This release adds the following enhancements for DNS Firewall

        bull Threat severity levels for RPZ zones bull Threat details in the syslog bull Categorization and filtering for DNS and Advanced DNS Protection syslog messages bull Severity level in the DNS Top RPZ Hits report

        Automated Mitigation of Phantom Domain Attacks This release provides a few CLI commands for mitigating phantom domain attacks in which a flood of queries are sent to resolve non-existent domains When phantom domain attacks happen the recursive server continues to query non-responsive servers spending valuable resources waiting for responses When resources are fully consumed the recursive server may drop legitimate queries causing serious performance issues To mitigate phantom domain attacks you can use the following CLI commands to control queries to non-responsive servers set holddown set fetches_per_server set fetches_per_zone and set recursion_query_timeout For information about these commands refer to the Infoblox CLI Guide DNSSEC Enhancement You can now add multiple cryptographic algorithms that the Grid Master uses when it generates the KSK and ZSK When you add multiple algorithms at the Grid level you can override them at the zone level By default the appliance uses RSASHA1 for both KSK and ZSK You can now add DSA RSAMD5 RSASHA1 RSASHA-256 or RSASHA-512 algorithms Configuring Fixed Addresses without Restarting DHCP Service When you configure or modify a fixed address a DHCP service restart is required by default in order for the new configuration to take effect You can now override this default behavior by enabling the appliance to take immediate action without restarting DHCP service when you configure or modify a fixed address that is outside a DHCP range You can enable this feature at the Grid or member level For Cloud Network Automation deployment this feature is automatically enabled on the Cloud Platform Appliance that has a valid Cloud Platform license installed Ignoring MAC Addresses for New Leases In addition to the UID (unique client identifier) you can now set the DHCP server to ignore the MAC address (hardware address) of a DHCP client when it places a request to the DHCP server for a new lease When you configure the appliance to ignore the MAC addresses of DHCP clients you can specify up to 10 MAC addresses to be ignored

        NIOS 701 Release Notes

        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 7 of 21 400-0579-001 Rev A 1212015

        Name Server Groups for Delegated Zones When you configure a name server group you can now create a set of external name servers as a delegation name server group and assign it to delegated zones Specifying a single delegation name server group instead of configuring multiple name servers individually for delegated zones can significantly reduce configuration efforts Network Insight Assets for Trunk Reports Device discovery now includes in the Asset tab all hosts (physical and virtual) connected to a trunk port Reporting Enhancement This release adds the capability to email reporting search results Infoblox API and RESTful API Enhancement This release adds newly supported objects for the API and RESTful API CHANGES TO DEFAULT BEHAVIOR This section lists changes to default behavior in NIOS 70x and 6x releases NIOS 700

        bull Starting with this release you must have IPv6 addresses for both nodes in an HA pair if one of them has an IPv6 address This was optional in previous releases

        bull In previous releases when you apply a non-global DHCP option filter to a DHCP range the appliance may return option 43 in the response Starting with this release the appliance does not return option 43 in any responses when you apply a non-global DHCP option filter to a range

        NIOS 6x Releases bull In previous releases you could configure DHCP Option 60 (Vendor Class Identifier) match rules

        associated with Microsoft option_space in the Grid or member DHCP properties or DHCP option filters associated with Microsoft option_space Starting with this release these configurations are no longer supported and you cannot configure them

        bull Reporting The ldquoDomain Namerdquo and ldquoMitigation Actionrdquo filters are no longer supported in the Top RPZ Hits by Client report

        bull In previous releases the appliance added grace period to the KSK (Key Signing Key) and ZSK (Zone Signing Key) rollover periods In this release the rollover periods for a particular zone start as soon as it is signed

        bull In previous releases you could assign read-only permission for hosts in a network to restrict admins to only viewing hosts in the specified network In this release assigning read-only permission for hosts in a network does not affect the visibility of hosts in the specified network

        CHANGES TO Infoblox API and RESTful API This section lists changes made to the Infoblox API and RESTful API in NIOS releases For detailed information about the supported methods and objects refer to the latest versions of the Infoblox API Documentation and the Infoblox WAPI Documentation available through the NIOS products and on the Infoblox Support web site The latest available RESTful API version is 20

        NIOS 701 Release Notes

        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 8 of 21 400-0579-001 Rev A 1212015

        RESTful API Deprecation and Backward Compatibility Policy This policy covers the interfaces exposed by the Infoblox RESTful API and the protocol used to communicate with it

        Unless explicitly stated in the release notes previously available RESTful API versions are intended to remain accessible and operative with later versions

        The planned deprecation of a given version of the RESTful API will normally be announced in the release notes at least one year in advance Upon deprecation the announced RESTful API version and all prior versions will no longer be supported in subsequent releases For example if the current RESTful API release is v34 and the release notes contain an announcement of the v15 deprecation v14 and v15 API requests would continue to work with later releases for one year from the announcement date After that some or all requests for these deprecated versions may not work with versions later than v15 API requests adherent to versions later than v15 (v20 for example) would continue to work with subsequent releases Infoblox seeks to avoid any deprecation that has not been announced in advance however product modifications and enhancements may affect specific API requests without a prior announcement Infoblox does not warrant that all API requests will be unaffected by future releases This policy applies to both major and minor versions of the RESTful API Infoblox reserves the right to change this policy NIOS 70x

        bull When executing a RESTful API request from version 20 and later the XML data format has been updated to accommodate tag names (used primarily in extensible attributes) that contain spaces andor invalid XML characters

        NIOS 6x Releases

        bull The RESTful API (WAPI) sample code advises using curl -k3 to access the RESTful API through SSLv3 SSLv3 is no longer supported and the ndashk3 option in curl is no longer supported To correctly use curl to access the RESTful API specify curl -k1 to force the use of TLS

        bull The following changes for keytabs have been made in the Infoblox API

        remove_datakeytab has been removed

        import_datakeytab has been removed

        import_dataupload_keytab has been added

        The API also supports multiple TSIG keys To use a keytab you must upload it and manually assign it to individual members or to DHCP you cannot complete this task in one operation If you have only one keytab you can still use the old gss_tsig members However Infoblox recommends that you switch to the new gss_tsig_keysipv6_gss_tsig_keys members

        bull The following objects have been deprecated in the Infoblox API

        InfobloxGridMSServerDNS (new object InfobloxGridMSServerServerDNS)

        status_last_updated member in InfobloxGridMSServerDNS (new object status_last_updated_ts member in epoc format)

        Though the deprecated objects will continue to function for backward compatibility purposes Infoblox recommends that you use the new objects in your new code

        bull The InfobloxGridAdminUser object password method and the InfobloxGrid object secret method have been modified to adhere to Infoblox security policies

        NIOS 701 Release Notes

        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 9 of 21 400-0579-001 Rev A 1212015

        bull API and RESTful API After upgrading to NIOS 67x all international domain names (IDNs) in punycode are converted to Unicode (in the respective API way of encoding Unicode strings) You can use the dns_[hellip] fields in relevant objects to retrieve read-only IDNs in punycode For more information about IDNs refer to the Infoblox NIOS Administrator Guide For information about API and RESTful API refer to the Infoblox API Documentation and Infoblox RESTful API Documentation

        UPGRADE GUIDELINES Upgrading to NIOS 70x NOTES

        bull You cannot upgrade NIOS 6124 to NIOS 70x You will however be able to upgrade NIOS 6124 and later to NIOS 71x releases when they become available

        bull You cannot upgrade directly from NIOS 5x to NIOS 70x However you can first upgrade to NIOS 66x or later and then to NIOS 70x

        You cannot upgrade to NIOS 70x on the following appliances IB-250-A IB-550-A IB-1050-A IB-1550-A IB-1552-A IB-1852-A IB-2000 IB-2000-A IB-VM-250 IB-VM-550 IB-VM-1050 IB-VM-1550 IB-VM-1850 IB-VM-2000 and Trinzic Reporting TR-2000 series appliances For information about supported platforms see Supported Platforms on page 1 Note the following for IPv6 Grid support

        bull If your Grid Master is configured with an IPv6 VIP all Grid Master Candidates must also include an IPv6 VIP For an HA pair both nodes of the HA pair must have IPv6 addresses for the Grid Master and the Grid Master Candidate

        bull After you upgrade to NIOS 70x Infoblox recommends that you back up the configuration after you change network connectivity to a different mode (IPv4 IPv6 or IPv4 and IPv6 dual mode) Restoring an old backup by performing a forced restore may prevent some Grid members from rejoining the Grid after the restore

        bull IPv6-only configuration does not support the following HSM LCD NAT groups OSPF and BGP

        When you schedule a full upgrade from a previous release to NIOS 70x the following DNSSEC limitations are applicable

        bull You cannot configure new settings that are added to the authoritative zone object while the upgrade is still in progress This restriction is not applicable to future upgrades

        bull When you upgrade you can sign or unsign an authoritative zone only if the Grid Master Candidate and the associated serving members are upgraded This restriction is not applicable to future upgrades

        bull An authoritative zone can have its KSK rollover only if the Grid Master Candidate and all the serving members are upgraded This restriction is not applicable to future upgrades

        bull An authoritative zone can have its ZSK rollover by the daemon only if the Grid Master Candidate and all the serving members are upgraded This restriction is not applicable to future upgrades

        bull You cannot delete keys while the upgrade is still in progress bull You cannot update DNSSEC related parameters at the member level while the upgrade is still in

        progress Example rollover mechanism NSEC3 salt length and iterations and enable or disable automatic KSK rollover

        NIOS 701 Release Notes

        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 10 of 21 400-0579-001 Rev A 1212015

        For Cloud Network Automation bull After upgrading to NIOS 70x you must manually select the Delegated To Cloud Usage

        and Owned By columns in the Data Management tab of Grid Manager to display relevant information This is applicable only if you have installed the Cloud Network Automation license on the Grid Master

        BEFORE YOU INSTALL To ensure that new features and enhancements operate properly and smoothly Infoblox recommends that you evaluate the capacity on your Grid and review the upgrade guidelines before you upgrade from a previous NIOS release Infoblox recommends that administrators planning to perform an upgrade from a previous release create and archive a backup of the Infoblox appliance configuration and data before upgrading You can run an upgrade test before performing the actual upgrade Infoblox recommends that you run the upgrade test so you can resolve any potential data migration issues before the upgrade Following is a list of upgrade and revert paths You can also schedule a full upgrade from these releases 700 6122 and earlier 612x releases 6117 and earlier 611x releases 610201 and 610200 61010 and earlier 610x releases 69201-LD and 69200-LD 690 6813 and earlier 68x releases 678 and earlier 67x releases 6613 and earlier 66x releases Technical Support Infoblox technical support contact information

        Telephone 1-888-463-6259 (toll-free US and Canada) +1-408-625-4200 ext 1

        E-mail supportinfobloxcom

        Web httpssupportinfobloxcom

        GUI Requirements Grid Manager supports the following operating systems and browsers You must install and enable Javascript for Grid Manager to function properly Grid Manager supports only SSL version 3 and TLS version 1 connections Infoblox recommends that you use a computer that has a 2 GHz CPU and at least 1 GB of RAM

        NIOS 701 Release Notes

        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 11 of 21 400-0579-001 Rev A 1212015

        Infoblox supports the following browsers for Grid Manager

        OS Browser Microsoft Windows 80 and 81reg Microsoft Internet Explorerreg 11x 10x

        Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

        Microsoft Windows 7reg Microsoft Internet Explorerreg 11x 10x 9x and 8x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

        Microsoft Windows XPreg (SP2+) Microsoft Internet Explorer 7x and 8x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

        Red Hatreg Enterprise Linuxreg 7x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

        Red Hatreg Enterprise Linuxreg 6x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

        Red Hatreg Enterprise Linux 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

        Applereg Mac OS X 109x Safari 7x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

        Applereg Mac OS X 108x Safari 6x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

        Applereg Mac OS X 107x Safari 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

        Applereg Mac OS X 106x Safari 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

        NOTE Grid Manager fully supports Microsoft Internet Explorerreg 11x and 10x when you enable compatibility view in the browser Features in the Reporting tab may not function properly if you disable compatibility view In the browser go to Tools -gt Compatibility View to enable the feature When viewing Grid Manager set the screen resolution of your monitor as follows

        Minimum resolution 1280 x 768 Recommended resolution 1280 x 1024 or better

        Documentation You can download the Infoblox NIOS Administrator Guide from the appliance From Grid Manager expand the Help panel and then click Documentation -gt Admin Guide Training Training information is available at httpinterviewcentralcomeventsuploadsinfobloxloginhtml

        NIOS 701 Release Notes

        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 12 of 21 400-0579-001 Rev A 1212015

        ACCESSING GRID MANAGER Before you log in to Grid Manager ensure that you have installed your NIOS appliance as described in the installation guide or user guide that shipped with your product and configured it accordingly To log in to Grid Manager

        1 Open an Internet browser window and enter httpsltIPv4 address or hostname of your NIOS appliancegt or https[IPv6 address] of your NIOS appliance The Grid Manager login page appears

        2 Enter your user name and password and then click Login or press Enter The default user name is admin and password is infoblox

        3 Read the Infoblox End-User License Agreement and click I Accept to proceed Grid Manager displays the Dashboard your home page in Grid Manager

        ADDRESSED VULNERABILITIES This section lists security vulnerabilities that were addressed in the past 12 months For vulnerabilities that are not listed in this section refer to Infoblox KB 2899 For additional information about these vulnerabilities including their severities please refer to the National Vulnerability Database (NVD) at httpnvdnistgov The Infoblox Support website at httpssupportinfobloxcom also provides more information including vulnerabilities that do not affect Infoblox appliances CERT VULNERABILITY NOTE CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation CERT VULNERABILITY NOTE CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet CERT VULNERABILITY NOTE CVE-2014-3566 SSL3 is vulnerable to man-in-the-middle-attacks SSL3 is disabled in NIOS and connections must use TLSv1 (which is already used by all supported browsers)

        CERT VULNERABILITY NOTE CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

        CERT VULNERABILITY NOTE CVE-2014-7187 Off-by-one error in the read_token_word function in parsey in GNU BASH through v 43 allowed remote attackers to cause a denial of service (out-of-bounds array access and application crash) or possibly an unspecified impact through deeply nested for loops (also known as the word_lineno issue)

        CERT VULNERABILITY NOTE CVE-2014-7186 The redirection implementation in parsey in GNU BASH through v 43 allowed remote attackers to cause a denial of service (out-of-bounds array access and application crash) or possibly an unspecified impact through the redir_stack issue

        CERT VULNERABILITY NOTE CVE-2014-6271 CVE-3014-6277 CVE-2014-6278 AND CVE-2014-7169 GNU Bash through v 43 processed trailing strings after function definitions in the values of environment variables which allowed remote attackers to execute arbitrary code via a crafted environment (also known as the ShellShock vulnerability)

        NIOS 701 Release Notes

        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 13 of 21 400-0579-001 Rev A 1212015

        CERT VULNERABILITY NOTE CVE-2014-3470 Enabling anonymous ECDH cipher suites on TLS clients could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0224 A specially crafted handshake packet could force the use of weak keying material in the SSLTLS clients allowing a man-in-the-middle (MITM) attack to decrypt and modify traffic between a client and a server CERT VULNERABILITY NOTE CVE-2014-0221 Remote attackers could utilize DTLS hello message in an invalid DTLS handshake to cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0198 Enabling SSL_MODE_RELEASE_BUFFERS failed to manage buffer pointer during certain recursive calls that could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0195 Remote attackers could trigger buffer overrun attack through invalid DTLS fragments to an OpenSSL DTLS client or server resulting in a denial of service CERT VULNERABILITY NOTE CVE-2014-0591 A crafted query against an NSEC3-signed zone could cause the named process to terminate RESOLVED ISSUES The following issues were reported in previous NIOS releases and resolved in this release The resolved issues are listed by severity For descriptions of the severity levels refer to Severity Levels on page 16 Fixed in 701

        ID Severity Summary

        NIOS-51535 Major An IPv6 address configured before NIOS 640 was not properly preserved during an upgrade to NIOS 700 which caused an error during product initialization

        Fixed in 700

        ID Severity Summary

        NIOS-50432 Critical Addressed zone journal file size issues that caused DNS service to slow down

        NIOS-50295 Critical After a DIW import there were some missing delegations and records in the Grid data set

        NIOS-50162 NIOS-50124

        Critical Under certain circumstances intermittent DNS service interruptions occurred

        ID Severity Summary

        NIOS-51186 Major DNS failed to respond to some queries due to new limits exposed by CVE-2014-8500

        NIOS-51051 Major DNS service interruptions occurred after changing RPZ records

        NIOS 701 Release Notes

        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 14 of 21 400-0579-001 Rev A 1212015

        NIOS-50894 Major Updated the Infoblox NIOS Administrator Guide to include information about virtual TFTP root is supported only for file downloads but not for file uploads using TFTP client

        NIOS-50784 Major Addressed the following OpenVPN vulnerability CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet

        NIOS-50532 Major Addressed the following vulnerabilities CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation

        NIOS-50617 NIOS-49810

        Major Grid Manager inappropriately marked IPv6 leases as having invalid MAC addresses

        NIOS-50575 Major NIOS did not show the root domain for Microsoft servers belonging to two Domains in the same Forest

        NIOS-50567 Major DIW failed to handle common CNAME records in different DNS views

        NIOS-50453 Major Added information about HA Grid Master providing NTP service through VIP to the Infoblox NIOS Administrator Guide

        NIOS-50402 Major Under certain circumstances NIOS returned option 43 in the response when users applied a non-global IPv4 option filter to a DHCP range

        NIOS-50250 Major Unable to remove a Grid from the Master Grid

        NIOS-50208 Major On some occasions the inheritance state for inherited extensible attributes was displayed as ldquooverriddenrdquo instead of ldquoinheritedrdquo

        NIOS-50199 Major Unable to modify a DHCP scope that was synchronized from a Microsoft DHCP failover partner

        NIOS-50171 Major Users could not convert a lease to a fixed address without the ldquoNetwork Discoveryrdquo permission which was not required

        NIOS-50137 Major VLAN tagging was not functional properly on the HA interface

        NIOS-50112 Major High CPU usage on Captive Portal caused by the ldquoomshellrdquo process

        NIOS-50081 Major Unable to add the same IPv6 loopback address on other Grid members when the IPv6 address is already configured on the Grid Master

        NIOS-50057 Major DHCP service interruptions occurred after an upgrade due to issues related to disabled Grid members in a MAC address filter

        NIOS-50052 Major Addressed the following SSL 30 vulnerability CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

        NIOS-49962 Major Unable to edit and save Upgrade Schedule

        NIOS-49941 Major In a Multi-Grid configuration the Master Grid experienced high swap usage while processing a lot of data

        NIOS-49935 Major Under certain circumstances exporting visible data from Grid Manager could fail for a zone

        NIOS 701 Release Notes

        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 15 of 21 400-0579-001 Rev A 1212015

        NIOS-49934 Major API On rare occasions searching with return_methods could result in incorrect PAPI results

        NIOS-49847 Major The appliance returned an error when users tried to disable GSS-TSIG and remove the keys

        NIOS-49826 Major Could not start DNS service on the Grid Secondary for a zone that had an external Primary while moving the LAN2 IP address from one member to the other

        NIOS-49809 Major In a network template users could not save values for an extensible attribute that was a ldquolistrdquo type

        NIOS-49735 Major The status of a Microsoft server was ldquoConnectingrdquo even when synchronization was in progress

        NIOS-49505 Major High disk space usage was observed after enabling ldquoCapture DNS Queriesrdquo and ldquoCapture DNS Responsesrdquo

        NIOS-49473 Major On rare occasions the Grid Master rebooted and went offline

        NIOS-49349 Major The infobloxlog captured bloxTools user password in plain text

        NIOS-49339 Major Grid Manager access was denied due to a missing object in the backup file

        NIOS-49137 Major Advanced DNS Protection An unexpected HA failover occurred due to a general protection fault

        NIOS-48437 Major DNS latency for DNS responses from cache was higher than usual for a duration of a couple seconds

        NIOS-48009 Major A schedule upgrade did not function properly if the HA Grid Master had not replicated the schedule to the passive node before the upgrade started

        NIOS-47994 Major DHCP service failed to start due to invalid DHCP option spaces defined in the DHCP configuration file

        NIOS-50571 Minor Added descriptions about VLAN tag and DSCP support for TE-1400 series appliances to the Infoblox NIOS Administrator Guide

        NIOS-50466 Minor DNS service startup took longer than expected due to journal file fragmentation

        NIOS-50430 Minor Redefined the description for ldquoinfoblox-deny-rpzrdquo in the Infoblox NIOS Administrator Guide

        NIOS-50401 Minor When associating a network with a Microsoft site an error message was displayed in the background instead of inside the editor

        NIOS-50366 Minor Updated the CSV Import Reference to include the file format for ldquoresponsepolicyipaddressrdquo objects

        NIOS-50267 Minor Unable to perform a discovery for a Microsoft managed subnet

        NIOS-49986 Minor Updated IP addresses used in example in the Infoblox NIOS Administrator Guide

        NIOS-49838 Minor Could not transfer support bundle using the transfer_supportbundle command

        NIOS-49816 Minor The Discoverer field value was truncated in the IP MAP viewer under the Discovered Data tab

        NIOS-49787 Minor The appliance logged excessive debugging messages

        NIOS 701 Release Notes

        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 16 of 21 400-0579-001 Rev A 1212015

        NIOS-48037 Minor Value for the extensible attribute ldquoSiterdquo was not displayed in the Lease Selector when

        users tried to connect to an auto-provisioned member

        NIOS-50399 Enhance Enhanced the ldquoConvertrdquo button to also appear in the IPAM home page

        Severity Levels Severity Description

        Critical Core network services are significantly impacted Major Network services are impacted but there is an available workaround Moderate Some loss of secondary services or configuration abilities Minor Minor functional or UI issue Enhance An enhancement to the product

        KNOWN GENERAL ISSUES

        ID Summary

        NIOS-51323 DNS Traffic Control The appliance may return a timeout error while loading the Traffic Management tab in Grid Manager if you have configured health monitoring for a lot of DTC servers

        NIOS-51287 Cloud Network Automation Modifying resource records through the cloud API will cause extensible attribute values to be removed

        NIOS-51235 In a Multi-Grid configuration converting network connectivity for the Master Grid and its sub Grids to IPv6 only is not supported even though Grid Manager may allow you to do so

        NIOS-51134 Infoblox appliances currently do not support HP passive copper cables

        NIOS-51054 After you upgrade to NIOS 700 Infoblox recommends that you back up the configuration after you change network connectivity to a different mode (IPv4 IPv6 or IPv4 and IPv6 dual mode) Restoring an old backup by performing a forced restore may prevent some Grid members from rejoining the Grid after the restore

        NIOS-50997 In this release the appliance does not automatically create a reverse-mapping zones for 1 for DNS servers that support IPv6

        NIOS-50873 When you enable DNS and DHCP services for IPv6 only DDNS updates may not function properly for certain configurations Infoblox recommends that you do not enable DDNS updates in an IPv6-only Grid

        NIOS-50859 Creating custom IPv6 NS records and pointing a zone to a particular IPv6 name server is not supported in this release

        NIOS-50994 Cloud Network Automation When there is no tenant associated with a network or VM or if a network or VM is created by a cloud adapter but the tenant ID is not specified in the cloud API request the Name or ID column for the tenant or VM is left blank in Grid Manager which implies ldquoNArdquo or not applicable for the specified network or VM

        NIOS 701 Release Notes

        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 17 of 21 400-0579-001 Rev A 1212015

        NA Reporting When there is too much data being displayed in a graph data can overlap each other and make it difficult for viewing You can expand the graph to view specific data by stretching the graph on display However you will not be able to download the expanded graph in a PDF Workaround Right-click the expanded graph and then select This Frame -gt Print Frame from the drop-down menu to print the graph

        NIOS-49238 Network Insight Under certain circumstances deleting networks may not remove the corresponding IP helper addresses from the device configuration

        NIOS-49123 Network Insight When scheduling a discovery or port control blackout the scheduled time and time zone will always be standard time No time adjustments are made if the selected time zone is currently in daylight savings time and no adjustments are made when the time zone switches to daylight savings time

        NIOS-49107 Network Insight If a recurring port control blackout is scheduled and it includes the current time port control tasks will be delayed during the current blackout period However you may not be warned until the next blackout period If a recurring discovery blackout is scheduled and it includes the current time the Discover Now functionality may not be blocked until the next blackout period

        AUGUSTA2-1606

        Network Insight Some devices such as the Cisco 3750X may report interfaces (that are not actually functional) as available through SNMP which could cause Port Control jobs on these non-functional interfaces to fail

        NIOS-48944 Reporting When there are disconnected data points in the reporting data for reports (such as the DNS Query Rate by Query Type report) that support the stacked area panel type the stacked area that represents the disconnected data in the PDF report may not fill up accordingly and may cause it to look like a line chart when it is actually a stacked area chart Workaround Interpret the information correctly when reading the stacked area charts that contain disconnected data points

        NIOS-48912 Network Insight Is a device is not connected to another host through a network the appliance will not be able to detect the Voice VLAN information

        NIOS-48897 Network Insight Alcatel Omniswitches can operate in two modesmdashWorking mode and Certified mode Alcatel OmniSwitch 6000 devices must run in Working mode to allow Port Control jobs to work on these devices

        NIOS-48704 Reporting When you configure a search for Top Devices Denied an IP Address using Member Network View Network and CIDR as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

        NIOS-48560 Network Insight Before joining the Network Data Consolidator to the Grid use the CLI command reset net-automation database to ensure that previously discovered device information is removed from the database

        NIOS-48399 You cannot restore the existing deleted resource records from the Recycle Bin after you promote a Grid Master Candidate to the Grid Master

        NIOS-48311 On the IB-4010 appliance the maximum resource records allowed in a single signing zone is 800K not 25 of the object limit as in other platforms Exceeding this limit may result in a system restart

        NIOS-48135 bloxTools data prior to NIOS 640 cannot be restored on NIOS 611x Workaround Upgrade to NIOS 64x first to get a backup before upgrading to NIOS 611x

        NIOS 701 Release Notes

        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 18 of 21 400-0579-001 Rev A 1212015

        NIOS-48030 You may not be able to log in to the bloxTools Workflow environment if you download the snapin-workflow file from the bloxTools Community site

        NIOS-47959 Through the API and RESTful API users can add records and data without entering values for required extensible attributes Users cannot do the same through Grid Manager

        NIOS-46356 An upgrade may fail if you clone reports and searches with duplicate names for the following reports DNS Query Rate by Server DNS Daily Query Rate by Server DNS Daily Peak Hour Query Rate by Server DHCP Device Operating System Trend DHCP Top Device Operating System and Traffic Rate

        NIOS-46290 In some scenarios upgrading from NIOS 67x to NIOS 610x on an Infoblox-4030 appliance may require a manual restart to complete the upgrade

        NIOS-46102 Advanced DNS Protection You may not be able to join an independent appliance to the Grid if the appliance has threat protection service enabled and only the LAN interface configured Workaround Disable threat protection service on the appliance before joining the Grid or configure the MGMT port and enable VPN on MGMT before joining the offline appliance to the Grid

        NIOS-46051 Reporting When you configure a search for Threat Protect Event Count by Severity Trend using Member Category and Rule ID as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

        NIOS-45906 Network Insight On rare occasions when there is incomplete inaccurate or misinterpreted data in discovered spanning tree information the appliance may not be able to determine the correct switch to which an end host is attached In this scenario the appliance may display inaccurate discovered data

        NIOS-45904 Network Insight In Grid Manager the same end host on different VLANs may appear as duplicates that contain the same VLAN information

        NIOS-45872 Content in the bloxHub widget on the Status Dashboard may not be displayed in certain versions of Google Chrome Mozilla FireFox and Microsoft Internet Explorer browsers due to security updates implemented by these browsers Workarounds For Chrome Click the security shield icon next to the URL and select Load unsafe script For FireFox Click the security shield icon next to the URL and select Disable Protection on This Page from the drop-down list For IE Click Show all content in the Only secure content is displayed message bar at the bottom of the page

        NIOS-45598 Network Insight When a seed router is specified for an IP address that has already been assigned as a fixed address the IP will still be discovered even if the fixed address is excluded from discovery

        NIOS-45233 Reporting When you use Microsoft Internet Explorer 10x and disable ldquoCompatibility Viewrdquo you may not be able to view reports in the Reporting tab Workaround In the Internet Explorer 10 browser go to Tools -gt Compatibility View to enable the feature

        NIOS-45220 When you upgrade from NIOS 51r6-12 or earlier releases the Try Snapinstall option may not be available in the bloxTools environment after the upgrade Workaround Stop bloxTools service on the member console connect to the member through the CLI and execute the set bloxtools reset all command Once the reset process is complete restart the bloxTools service to access the Try Snapinstall option

        NIOS 701 Release Notes

        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 19 of 21 400-0579-001 Rev A 1212015

        VLAN-324 If you have assigned multiple VLANs to the LAN1 or LAN2 interfaces on the appliance you may receive messages about having ldquomultiple interfaces that match the same subnetrdquo during dhcpd process startups or restarts Note that these are not error messages and no actions are required

        NIOS-44055 If you use certain versions of Mozilla FireFox to run Grid Manager the auto-detected time zone feature may not function properly even if you have enabled it in your User Profile

        NIOS-43957 When you upgrade from NIOS 66x or earlier releases the email address in the SOA resource record that was entered in punycode will be converted into IDN (Internationalized Domain Name) after the upgrade Workaround Convert the IDN back to punycode using the IDN converter utility through Grid Manager

        NIOS-43569 You may not be able to view reverse-mapping zones in an internal DNS view Workaround Set the table size to 10 in User Profile log out and then log back in to the system again

        NIOS-41136 Reporting When you use certain versions of Mozilla Firefox and Google Chrome browsers on Windows 7 or Linux you may not be able to properly print reports

        NIOS-39922 On Trinzic 2200 series appliances it may take up to three minutes for the LOM (Light On Management) LED to stop blinking after you have disabled the LOM feature

        NIOS-38870 When you change the member type of an appliance from Infoblox to vNIOS the appliance might display an error message indicating that all network port settings of the vNIOS member must be changed to Automatic Workaround Through the Infoblox API use InfobloxGridMember and the functions lan_port_duplex( ) and lan_port_speed ( ) to change the network port settings for the vNIOS member

        NIOS-38579 Reporting If you have a quick filter that includes a filter criterion with report comment equals to a value that NIOS automatically translates to another value the quick filter may not function properly after an upgrade to NIOS 65 or 66 NIOS automatically translates the following ldquoIPAM Utilizationrdquo to ldquoDDI Utilizationrdquo ldquoDNS Zone Statistics per DNS Viewrdquo to ldquoDNS Statistics per DNS Viewrdquo ldquoDNS Zone Statistics per DNS Zonerdquo to ldquoDNS Statistics per Zonerdquo ldquoDNS Member QPS Trendrdquo to ldquoDNS Query Rate by Serverrdquo and ldquoDNS Queries per Second Trendrdquo to ldquoDNS Query Rate by Query Typerdquo Workaround 1 Edit the original report comment values to match the translated values For example if you have entered ldquoIPAM Utilizationrdquo in the comment field of a report change it to ldquoDDI Utilizationrdquo Workaround 2 Edit the quick filter names to match the original comment values For example if you have entered ldquoQF1rdquo as a quick filter name and ldquoIPAM Utilizationrdquo as the report comment change the quick filter name to ldquoIPAM Utilizationrdquo

        NIOS-37415 Users cannot execute Trinzic Automation Engine (TAE) if they log out of NetMRI during an active NetMRI session

        NIOS-33600 There is an issue with SafeNet HSMs in that configuration changes do not immediately take effect such as when adding a new member to an existing SafeNet HSM Group deleting a client from the HSM or making member changes You can perform a forced restart of services to apply the changes immediately

        NIOS-31864 Modifying a zone from a client increments the zonersquos serial number even if the zone contents did not change This causes unnecessary AXFRs to secondary servers and if the zone is served by a Microsoft Server that is managed in read-write mode it causes extra synchronizations as well

        NIOS 701 Release Notes

        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 20 of 21 400-0579-001 Rev A 1212015

        NIOS-31501 When a Microsoft server is the primary server for a zone and another Microsoft server is hosting the same zone as a stub zone and the NIOS appliance synchronizes DNS data with only one of these zones it will synchronize the zone as an authoritative or stub zone depending on which Microsoft server it synchronizes with first For more information please refer to KB article 17593

        NIOS-25064 (45488)

        If you configured a member DHCP server to authenticate DHCP clients with a RADIUS authentication server group and RADIUS is disabled (the server group is disabled all RADIUS servers in the group are disabled or the member DHCP server was not assigned an authentication server group) NAC filters with ldquodoes not equalrdquo rules will always match Workaround Do not disable RADIUS

        NIOS-21512 (39917)

        When you stop the DNS service of an independent appliance with temporary DNS and DHCP licenses Grid Manager displays the Restart Services panel regardless of which function you select

        NIOS-21499 (38968)

        An admin cannot display DNS views created by other admins during the same browser session To display the DNS views created by other admins you must log out and log in again

        NIOS-19853 (31668)

        Grid Manager does not display an error when you move a DNS view to a network view that contains a host record that has the same MAC address as a host record in the DNS view that is being moved

        NIOS-19144 (30208)

        Grid Manager does not sort columns correctly in the IPAM and Network list panels when the columns contain UTF-8 data

        NIOS-18163 (27831)

        The appliance allows users with read-only permission to A records to view DNSSEC resource records as well

        NIOS-17636 (26233)

        Syslog messages generated during a TFTP file transfer display the incorrect time zone

        NIOS-17513 (26080)

        Adding updating or deleting reverse zones could fail due to unsupported PTR records in the root zone

        PAPIPASS-39

        When you use Mozilla Firefox 16x 17x or Mozilla Firefox Beta 180b3 browser the hidden password in the Add Administrator Wizard of Grid Manager may disappear when you click the Password field after you have confirmed the password This is a known issue when you use Firefox browsers

        MME-154 When a NIOS user deletes a Microsoft AD domainrsquos primary zones and subzones NIOS should display a more specific message warning users about the consequences of the operation instead of the general warning message it currently displays

        MME-129 When a Microsoft admin creates a delegation on the Microsoft server and the delegation is synchronized to the NIOS appliance the glue A record of the delegation name server is synchronized to the appliance as a manually created record If on the NIOS appliance an admin changes the IP address on the NS record of the delegation name server two A glue records are generated one with the original address one with the new address NIOS retains the original glue A record because itrsquos marked as a manually created record and it can only be changed or deleted either manually on Grid Manager or through the API When synchronization occurs the Microsoft server correctly updates the existing glue A record and does not retain the original Note that NIOS retains the original A record only after the initial update If you update the A record again NIOS just updates the existing record without retaining the original

        MME-23 NIOS displays an ldquoInternal Errorrdquo message when you try to apply a quick filter for a range that equals 1 when you display a range in the IPv4 Microsoft Superscopes tab

        MME-6 If you add a hostname to the Target field of an SRV record on Grid Manager when the member synchronizes the SRV record to a Microsoft server it adds a new SRV record with the hostname instead of modifying the existing record

        NIOS 701 Release Notes

        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 21 of 21 400-0579-001 Rev A 1212015

        MSSS-11 (45296)

        When you run a discovery on a network served by Microsoft servers and Grid Manager discovers a MAC address that does not match any of the fixed addresses associated with an IP address it reports a conflict and lists the associated fixed address objects in the Related Objects table You cannot select which fixed address to resolve in the Related Objects table You can only resolve the conflict for the first address

        VNIOS-36 (41215)

        If a virtual NIOS member does not start up due to a license violation Grid Manager displays the status of the vNIOS member as ldquoonlinerunningrdquo even though the member is not online

        • INTRODUCTION
          • Supported Platforms
            • NEW FEATURES
              • NIOS 700
                • CHANGES TO DEFAULT BEHAVIOR
                  • NIOS 700
                  • NIOS 6x Releases
                    • CHANGES TO Infoblox API and RESTful API
                      • RESTful API Deprecation and Backward Compatibility Policy
                      • NIOS 70x
                      • NIOS 6x Releases
                        • UPGRADE GUIDELINES
                          • Upgrading to NIOS 70x
                            • BEFORE YOU INSTALL
                            • ACCESSING GRID MANAGER
                            • ADDRESSED VULNERABILITIES
                            • RESOLVED ISSUES
                              • Fixed in 701
                              • Fixed in 700
                                • KNOWN GENERAL ISSUES

          NIOS 701 Release Notes

          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 5 of 21 400-0579-001 Rev A 1212015

          Note that all vNIOS on VMware virtual appliances running on Cisco SRE-V are not recommended as Grid Masters or Grid Master Candidates The IB-BOB virtual appliance has been renamed to IB-VM-100 For new installation use the 55 GB software image IB-VM-100 only supports configuration as a Grid member

          bull vNIOS on Riverbedreg Steelhead Appliances

          Infoblox has certified the vNIOS on Riverbed software with the following Riverbed Steelhead models and software versions

          Riverbed Models Supported RiOS and EX versions

          1050 2050 5050 RiOS 75 RiOS 80 RiOS 85

          EX560 EX760 EX1160 EX1260 EX 10 (RiOS 7) EX 20 (RiOS 80) EX 25 (RiOS 80) EX 30 (RiOS 850) EX 31 (RiOS 851)

          For additional information refer to the Infoblox Installation Guide for vNIOS Software on Riverbed Steelhead Platforms NOTE You can upgrade a Grid with a Riverbed virtual member to NIOS 7x Ensure that the Riverbed model has 64 bit support

          NEW FEATURES This section lists new features in the 70x releases NIOS 700 Cloud Network Automation The Infoblox Cloud Network Automation solution automates IPAM (IP address management) for physical and virtual network devices on your CMP (Cloud Management Platform) Instead of manually provisioning IP addresses and DNS name spaces for network devices and interfaces you can use Cloud Network Automation to provision and manage IPAM DNS and DHCP within the Grid automatically as VMs (Virtual Machines) are created and destroyed When your Cloud consists of a large number of servers and VMs (virtual machines) that have multiple associated network interfaces manually provisioning and de-provisioning IP addresses and managing DNS and DHCP data can be error-prone and time consuming Utilizing Cloud Network Automation minimizes human errors by streamlining IP Address and DNS record management improves visibility of your cloud networks and maximizes the flexibility efficiency and agility of your cloud environment Cloud Network Automation includes two components the Grid Master that has a Cloud Network Automation license installed and one or more Cloud Platform Appliances The Cloud Network Automation license enables visibility and reporting on cloud tenant network VM IP address and DNS record allocation Cloud Platform Appliances enable processing of API requests from your CMP locally on the same appliances that serve DNS and DHCP to your cloud These appliances provide local survivability and additional scalability of Cloud API requests within your data centers in addition to the visibility provided by the Cloud Network Automation license on the Grid Master DNS Traffic Control Infoblox DNS Traffic Control provides a load balancing solution by adjusting DNS responses based on DNS query source IP server availability and network topology Through DNS Traffic Control you can set up multiple global sites and configure supported objects and load balancing methods to direct responses to the best available servers

          NIOS 701 Release Notes

          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 6 of 21 400-0579-001 Rev A 1212015

          Support for IPv6 Grid

          The Infoblox appliance now supports IPv6 networking configuration in most deployments You can deploy a Grid and configure a Grid Master Grid Member reporting member and an HA pair in one of the following modes IPv4 only IPv6 only or IPv4 and IPv6 dual mode You can also configure the default communication protocol settings using IPv4 or IPv6 In addition services and functionality such as NTP service DNS Firewall and admin notifications now support both IPv4 and IPv6 addresses In addition Grid communication can now support IPv6 only and you can configure an appliance with only IPv6 addresses (no IPv4 addresses are required) Support for Microsoft Sites This release enhances the Microsoft Management solution by adding support for managing Microsoft Active Directory Sites and Subnets on Microsoft servers through Grid Manager DNS Firewall Enhancements This release adds the following enhancements for DNS Firewall

          bull Threat severity levels for RPZ zones bull Threat details in the syslog bull Categorization and filtering for DNS and Advanced DNS Protection syslog messages bull Severity level in the DNS Top RPZ Hits report

          Automated Mitigation of Phantom Domain Attacks This release provides a few CLI commands for mitigating phantom domain attacks in which a flood of queries are sent to resolve non-existent domains When phantom domain attacks happen the recursive server continues to query non-responsive servers spending valuable resources waiting for responses When resources are fully consumed the recursive server may drop legitimate queries causing serious performance issues To mitigate phantom domain attacks you can use the following CLI commands to control queries to non-responsive servers set holddown set fetches_per_server set fetches_per_zone and set recursion_query_timeout For information about these commands refer to the Infoblox CLI Guide DNSSEC Enhancement You can now add multiple cryptographic algorithms that the Grid Master uses when it generates the KSK and ZSK When you add multiple algorithms at the Grid level you can override them at the zone level By default the appliance uses RSASHA1 for both KSK and ZSK You can now add DSA RSAMD5 RSASHA1 RSASHA-256 or RSASHA-512 algorithms Configuring Fixed Addresses without Restarting DHCP Service When you configure or modify a fixed address a DHCP service restart is required by default in order for the new configuration to take effect You can now override this default behavior by enabling the appliance to take immediate action without restarting DHCP service when you configure or modify a fixed address that is outside a DHCP range You can enable this feature at the Grid or member level For Cloud Network Automation deployment this feature is automatically enabled on the Cloud Platform Appliance that has a valid Cloud Platform license installed Ignoring MAC Addresses for New Leases In addition to the UID (unique client identifier) you can now set the DHCP server to ignore the MAC address (hardware address) of a DHCP client when it places a request to the DHCP server for a new lease When you configure the appliance to ignore the MAC addresses of DHCP clients you can specify up to 10 MAC addresses to be ignored

          NIOS 701 Release Notes

          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 7 of 21 400-0579-001 Rev A 1212015

          Name Server Groups for Delegated Zones When you configure a name server group you can now create a set of external name servers as a delegation name server group and assign it to delegated zones Specifying a single delegation name server group instead of configuring multiple name servers individually for delegated zones can significantly reduce configuration efforts Network Insight Assets for Trunk Reports Device discovery now includes in the Asset tab all hosts (physical and virtual) connected to a trunk port Reporting Enhancement This release adds the capability to email reporting search results Infoblox API and RESTful API Enhancement This release adds newly supported objects for the API and RESTful API CHANGES TO DEFAULT BEHAVIOR This section lists changes to default behavior in NIOS 70x and 6x releases NIOS 700

          bull Starting with this release you must have IPv6 addresses for both nodes in an HA pair if one of them has an IPv6 address This was optional in previous releases

          bull In previous releases when you apply a non-global DHCP option filter to a DHCP range the appliance may return option 43 in the response Starting with this release the appliance does not return option 43 in any responses when you apply a non-global DHCP option filter to a range

          NIOS 6x Releases bull In previous releases you could configure DHCP Option 60 (Vendor Class Identifier) match rules

          associated with Microsoft option_space in the Grid or member DHCP properties or DHCP option filters associated with Microsoft option_space Starting with this release these configurations are no longer supported and you cannot configure them

          bull Reporting The ldquoDomain Namerdquo and ldquoMitigation Actionrdquo filters are no longer supported in the Top RPZ Hits by Client report

          bull In previous releases the appliance added grace period to the KSK (Key Signing Key) and ZSK (Zone Signing Key) rollover periods In this release the rollover periods for a particular zone start as soon as it is signed

          bull In previous releases you could assign read-only permission for hosts in a network to restrict admins to only viewing hosts in the specified network In this release assigning read-only permission for hosts in a network does not affect the visibility of hosts in the specified network

          CHANGES TO Infoblox API and RESTful API This section lists changes made to the Infoblox API and RESTful API in NIOS releases For detailed information about the supported methods and objects refer to the latest versions of the Infoblox API Documentation and the Infoblox WAPI Documentation available through the NIOS products and on the Infoblox Support web site The latest available RESTful API version is 20

          NIOS 701 Release Notes

          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 8 of 21 400-0579-001 Rev A 1212015

          RESTful API Deprecation and Backward Compatibility Policy This policy covers the interfaces exposed by the Infoblox RESTful API and the protocol used to communicate with it

          Unless explicitly stated in the release notes previously available RESTful API versions are intended to remain accessible and operative with later versions

          The planned deprecation of a given version of the RESTful API will normally be announced in the release notes at least one year in advance Upon deprecation the announced RESTful API version and all prior versions will no longer be supported in subsequent releases For example if the current RESTful API release is v34 and the release notes contain an announcement of the v15 deprecation v14 and v15 API requests would continue to work with later releases for one year from the announcement date After that some or all requests for these deprecated versions may not work with versions later than v15 API requests adherent to versions later than v15 (v20 for example) would continue to work with subsequent releases Infoblox seeks to avoid any deprecation that has not been announced in advance however product modifications and enhancements may affect specific API requests without a prior announcement Infoblox does not warrant that all API requests will be unaffected by future releases This policy applies to both major and minor versions of the RESTful API Infoblox reserves the right to change this policy NIOS 70x

          bull When executing a RESTful API request from version 20 and later the XML data format has been updated to accommodate tag names (used primarily in extensible attributes) that contain spaces andor invalid XML characters

          NIOS 6x Releases

          bull The RESTful API (WAPI) sample code advises using curl -k3 to access the RESTful API through SSLv3 SSLv3 is no longer supported and the ndashk3 option in curl is no longer supported To correctly use curl to access the RESTful API specify curl -k1 to force the use of TLS

          bull The following changes for keytabs have been made in the Infoblox API

          remove_datakeytab has been removed

          import_datakeytab has been removed

          import_dataupload_keytab has been added

          The API also supports multiple TSIG keys To use a keytab you must upload it and manually assign it to individual members or to DHCP you cannot complete this task in one operation If you have only one keytab you can still use the old gss_tsig members However Infoblox recommends that you switch to the new gss_tsig_keysipv6_gss_tsig_keys members

          bull The following objects have been deprecated in the Infoblox API

          InfobloxGridMSServerDNS (new object InfobloxGridMSServerServerDNS)

          status_last_updated member in InfobloxGridMSServerDNS (new object status_last_updated_ts member in epoc format)

          Though the deprecated objects will continue to function for backward compatibility purposes Infoblox recommends that you use the new objects in your new code

          bull The InfobloxGridAdminUser object password method and the InfobloxGrid object secret method have been modified to adhere to Infoblox security policies

          NIOS 701 Release Notes

          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 9 of 21 400-0579-001 Rev A 1212015

          bull API and RESTful API After upgrading to NIOS 67x all international domain names (IDNs) in punycode are converted to Unicode (in the respective API way of encoding Unicode strings) You can use the dns_[hellip] fields in relevant objects to retrieve read-only IDNs in punycode For more information about IDNs refer to the Infoblox NIOS Administrator Guide For information about API and RESTful API refer to the Infoblox API Documentation and Infoblox RESTful API Documentation

          UPGRADE GUIDELINES Upgrading to NIOS 70x NOTES

          bull You cannot upgrade NIOS 6124 to NIOS 70x You will however be able to upgrade NIOS 6124 and later to NIOS 71x releases when they become available

          bull You cannot upgrade directly from NIOS 5x to NIOS 70x However you can first upgrade to NIOS 66x or later and then to NIOS 70x

          You cannot upgrade to NIOS 70x on the following appliances IB-250-A IB-550-A IB-1050-A IB-1550-A IB-1552-A IB-1852-A IB-2000 IB-2000-A IB-VM-250 IB-VM-550 IB-VM-1050 IB-VM-1550 IB-VM-1850 IB-VM-2000 and Trinzic Reporting TR-2000 series appliances For information about supported platforms see Supported Platforms on page 1 Note the following for IPv6 Grid support

          bull If your Grid Master is configured with an IPv6 VIP all Grid Master Candidates must also include an IPv6 VIP For an HA pair both nodes of the HA pair must have IPv6 addresses for the Grid Master and the Grid Master Candidate

          bull After you upgrade to NIOS 70x Infoblox recommends that you back up the configuration after you change network connectivity to a different mode (IPv4 IPv6 or IPv4 and IPv6 dual mode) Restoring an old backup by performing a forced restore may prevent some Grid members from rejoining the Grid after the restore

          bull IPv6-only configuration does not support the following HSM LCD NAT groups OSPF and BGP

          When you schedule a full upgrade from a previous release to NIOS 70x the following DNSSEC limitations are applicable

          bull You cannot configure new settings that are added to the authoritative zone object while the upgrade is still in progress This restriction is not applicable to future upgrades

          bull When you upgrade you can sign or unsign an authoritative zone only if the Grid Master Candidate and the associated serving members are upgraded This restriction is not applicable to future upgrades

          bull An authoritative zone can have its KSK rollover only if the Grid Master Candidate and all the serving members are upgraded This restriction is not applicable to future upgrades

          bull An authoritative zone can have its ZSK rollover by the daemon only if the Grid Master Candidate and all the serving members are upgraded This restriction is not applicable to future upgrades

          bull You cannot delete keys while the upgrade is still in progress bull You cannot update DNSSEC related parameters at the member level while the upgrade is still in

          progress Example rollover mechanism NSEC3 salt length and iterations and enable or disable automatic KSK rollover

          NIOS 701 Release Notes

          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 10 of 21 400-0579-001 Rev A 1212015

          For Cloud Network Automation bull After upgrading to NIOS 70x you must manually select the Delegated To Cloud Usage

          and Owned By columns in the Data Management tab of Grid Manager to display relevant information This is applicable only if you have installed the Cloud Network Automation license on the Grid Master

          BEFORE YOU INSTALL To ensure that new features and enhancements operate properly and smoothly Infoblox recommends that you evaluate the capacity on your Grid and review the upgrade guidelines before you upgrade from a previous NIOS release Infoblox recommends that administrators planning to perform an upgrade from a previous release create and archive a backup of the Infoblox appliance configuration and data before upgrading You can run an upgrade test before performing the actual upgrade Infoblox recommends that you run the upgrade test so you can resolve any potential data migration issues before the upgrade Following is a list of upgrade and revert paths You can also schedule a full upgrade from these releases 700 6122 and earlier 612x releases 6117 and earlier 611x releases 610201 and 610200 61010 and earlier 610x releases 69201-LD and 69200-LD 690 6813 and earlier 68x releases 678 and earlier 67x releases 6613 and earlier 66x releases Technical Support Infoblox technical support contact information

          Telephone 1-888-463-6259 (toll-free US and Canada) +1-408-625-4200 ext 1

          E-mail supportinfobloxcom

          Web httpssupportinfobloxcom

          GUI Requirements Grid Manager supports the following operating systems and browsers You must install and enable Javascript for Grid Manager to function properly Grid Manager supports only SSL version 3 and TLS version 1 connections Infoblox recommends that you use a computer that has a 2 GHz CPU and at least 1 GB of RAM

          NIOS 701 Release Notes

          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 11 of 21 400-0579-001 Rev A 1212015

          Infoblox supports the following browsers for Grid Manager

          OS Browser Microsoft Windows 80 and 81reg Microsoft Internet Explorerreg 11x 10x

          Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

          Microsoft Windows 7reg Microsoft Internet Explorerreg 11x 10x 9x and 8x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

          Microsoft Windows XPreg (SP2+) Microsoft Internet Explorer 7x and 8x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

          Red Hatreg Enterprise Linuxreg 7x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

          Red Hatreg Enterprise Linuxreg 6x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

          Red Hatreg Enterprise Linux 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

          Applereg Mac OS X 109x Safari 7x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

          Applereg Mac OS X 108x Safari 6x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

          Applereg Mac OS X 107x Safari 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

          Applereg Mac OS X 106x Safari 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

          NOTE Grid Manager fully supports Microsoft Internet Explorerreg 11x and 10x when you enable compatibility view in the browser Features in the Reporting tab may not function properly if you disable compatibility view In the browser go to Tools -gt Compatibility View to enable the feature When viewing Grid Manager set the screen resolution of your monitor as follows

          Minimum resolution 1280 x 768 Recommended resolution 1280 x 1024 or better

          Documentation You can download the Infoblox NIOS Administrator Guide from the appliance From Grid Manager expand the Help panel and then click Documentation -gt Admin Guide Training Training information is available at httpinterviewcentralcomeventsuploadsinfobloxloginhtml

          NIOS 701 Release Notes

          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 12 of 21 400-0579-001 Rev A 1212015

          ACCESSING GRID MANAGER Before you log in to Grid Manager ensure that you have installed your NIOS appliance as described in the installation guide or user guide that shipped with your product and configured it accordingly To log in to Grid Manager

          1 Open an Internet browser window and enter httpsltIPv4 address or hostname of your NIOS appliancegt or https[IPv6 address] of your NIOS appliance The Grid Manager login page appears

          2 Enter your user name and password and then click Login or press Enter The default user name is admin and password is infoblox

          3 Read the Infoblox End-User License Agreement and click I Accept to proceed Grid Manager displays the Dashboard your home page in Grid Manager

          ADDRESSED VULNERABILITIES This section lists security vulnerabilities that were addressed in the past 12 months For vulnerabilities that are not listed in this section refer to Infoblox KB 2899 For additional information about these vulnerabilities including their severities please refer to the National Vulnerability Database (NVD) at httpnvdnistgov The Infoblox Support website at httpssupportinfobloxcom also provides more information including vulnerabilities that do not affect Infoblox appliances CERT VULNERABILITY NOTE CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation CERT VULNERABILITY NOTE CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet CERT VULNERABILITY NOTE CVE-2014-3566 SSL3 is vulnerable to man-in-the-middle-attacks SSL3 is disabled in NIOS and connections must use TLSv1 (which is already used by all supported browsers)

          CERT VULNERABILITY NOTE CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

          CERT VULNERABILITY NOTE CVE-2014-7187 Off-by-one error in the read_token_word function in parsey in GNU BASH through v 43 allowed remote attackers to cause a denial of service (out-of-bounds array access and application crash) or possibly an unspecified impact through deeply nested for loops (also known as the word_lineno issue)

          CERT VULNERABILITY NOTE CVE-2014-7186 The redirection implementation in parsey in GNU BASH through v 43 allowed remote attackers to cause a denial of service (out-of-bounds array access and application crash) or possibly an unspecified impact through the redir_stack issue

          CERT VULNERABILITY NOTE CVE-2014-6271 CVE-3014-6277 CVE-2014-6278 AND CVE-2014-7169 GNU Bash through v 43 processed trailing strings after function definitions in the values of environment variables which allowed remote attackers to execute arbitrary code via a crafted environment (also known as the ShellShock vulnerability)

          NIOS 701 Release Notes

          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 13 of 21 400-0579-001 Rev A 1212015

          CERT VULNERABILITY NOTE CVE-2014-3470 Enabling anonymous ECDH cipher suites on TLS clients could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0224 A specially crafted handshake packet could force the use of weak keying material in the SSLTLS clients allowing a man-in-the-middle (MITM) attack to decrypt and modify traffic between a client and a server CERT VULNERABILITY NOTE CVE-2014-0221 Remote attackers could utilize DTLS hello message in an invalid DTLS handshake to cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0198 Enabling SSL_MODE_RELEASE_BUFFERS failed to manage buffer pointer during certain recursive calls that could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0195 Remote attackers could trigger buffer overrun attack through invalid DTLS fragments to an OpenSSL DTLS client or server resulting in a denial of service CERT VULNERABILITY NOTE CVE-2014-0591 A crafted query against an NSEC3-signed zone could cause the named process to terminate RESOLVED ISSUES The following issues were reported in previous NIOS releases and resolved in this release The resolved issues are listed by severity For descriptions of the severity levels refer to Severity Levels on page 16 Fixed in 701

          ID Severity Summary

          NIOS-51535 Major An IPv6 address configured before NIOS 640 was not properly preserved during an upgrade to NIOS 700 which caused an error during product initialization

          Fixed in 700

          ID Severity Summary

          NIOS-50432 Critical Addressed zone journal file size issues that caused DNS service to slow down

          NIOS-50295 Critical After a DIW import there were some missing delegations and records in the Grid data set

          NIOS-50162 NIOS-50124

          Critical Under certain circumstances intermittent DNS service interruptions occurred

          ID Severity Summary

          NIOS-51186 Major DNS failed to respond to some queries due to new limits exposed by CVE-2014-8500

          NIOS-51051 Major DNS service interruptions occurred after changing RPZ records

          NIOS 701 Release Notes

          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 14 of 21 400-0579-001 Rev A 1212015

          NIOS-50894 Major Updated the Infoblox NIOS Administrator Guide to include information about virtual TFTP root is supported only for file downloads but not for file uploads using TFTP client

          NIOS-50784 Major Addressed the following OpenVPN vulnerability CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet

          NIOS-50532 Major Addressed the following vulnerabilities CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation

          NIOS-50617 NIOS-49810

          Major Grid Manager inappropriately marked IPv6 leases as having invalid MAC addresses

          NIOS-50575 Major NIOS did not show the root domain for Microsoft servers belonging to two Domains in the same Forest

          NIOS-50567 Major DIW failed to handle common CNAME records in different DNS views

          NIOS-50453 Major Added information about HA Grid Master providing NTP service through VIP to the Infoblox NIOS Administrator Guide

          NIOS-50402 Major Under certain circumstances NIOS returned option 43 in the response when users applied a non-global IPv4 option filter to a DHCP range

          NIOS-50250 Major Unable to remove a Grid from the Master Grid

          NIOS-50208 Major On some occasions the inheritance state for inherited extensible attributes was displayed as ldquooverriddenrdquo instead of ldquoinheritedrdquo

          NIOS-50199 Major Unable to modify a DHCP scope that was synchronized from a Microsoft DHCP failover partner

          NIOS-50171 Major Users could not convert a lease to a fixed address without the ldquoNetwork Discoveryrdquo permission which was not required

          NIOS-50137 Major VLAN tagging was not functional properly on the HA interface

          NIOS-50112 Major High CPU usage on Captive Portal caused by the ldquoomshellrdquo process

          NIOS-50081 Major Unable to add the same IPv6 loopback address on other Grid members when the IPv6 address is already configured on the Grid Master

          NIOS-50057 Major DHCP service interruptions occurred after an upgrade due to issues related to disabled Grid members in a MAC address filter

          NIOS-50052 Major Addressed the following SSL 30 vulnerability CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

          NIOS-49962 Major Unable to edit and save Upgrade Schedule

          NIOS-49941 Major In a Multi-Grid configuration the Master Grid experienced high swap usage while processing a lot of data

          NIOS-49935 Major Under certain circumstances exporting visible data from Grid Manager could fail for a zone

          NIOS 701 Release Notes

          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 15 of 21 400-0579-001 Rev A 1212015

          NIOS-49934 Major API On rare occasions searching with return_methods could result in incorrect PAPI results

          NIOS-49847 Major The appliance returned an error when users tried to disable GSS-TSIG and remove the keys

          NIOS-49826 Major Could not start DNS service on the Grid Secondary for a zone that had an external Primary while moving the LAN2 IP address from one member to the other

          NIOS-49809 Major In a network template users could not save values for an extensible attribute that was a ldquolistrdquo type

          NIOS-49735 Major The status of a Microsoft server was ldquoConnectingrdquo even when synchronization was in progress

          NIOS-49505 Major High disk space usage was observed after enabling ldquoCapture DNS Queriesrdquo and ldquoCapture DNS Responsesrdquo

          NIOS-49473 Major On rare occasions the Grid Master rebooted and went offline

          NIOS-49349 Major The infobloxlog captured bloxTools user password in plain text

          NIOS-49339 Major Grid Manager access was denied due to a missing object in the backup file

          NIOS-49137 Major Advanced DNS Protection An unexpected HA failover occurred due to a general protection fault

          NIOS-48437 Major DNS latency for DNS responses from cache was higher than usual for a duration of a couple seconds

          NIOS-48009 Major A schedule upgrade did not function properly if the HA Grid Master had not replicated the schedule to the passive node before the upgrade started

          NIOS-47994 Major DHCP service failed to start due to invalid DHCP option spaces defined in the DHCP configuration file

          NIOS-50571 Minor Added descriptions about VLAN tag and DSCP support for TE-1400 series appliances to the Infoblox NIOS Administrator Guide

          NIOS-50466 Minor DNS service startup took longer than expected due to journal file fragmentation

          NIOS-50430 Minor Redefined the description for ldquoinfoblox-deny-rpzrdquo in the Infoblox NIOS Administrator Guide

          NIOS-50401 Minor When associating a network with a Microsoft site an error message was displayed in the background instead of inside the editor

          NIOS-50366 Minor Updated the CSV Import Reference to include the file format for ldquoresponsepolicyipaddressrdquo objects

          NIOS-50267 Minor Unable to perform a discovery for a Microsoft managed subnet

          NIOS-49986 Minor Updated IP addresses used in example in the Infoblox NIOS Administrator Guide

          NIOS-49838 Minor Could not transfer support bundle using the transfer_supportbundle command

          NIOS-49816 Minor The Discoverer field value was truncated in the IP MAP viewer under the Discovered Data tab

          NIOS-49787 Minor The appliance logged excessive debugging messages

          NIOS 701 Release Notes

          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 16 of 21 400-0579-001 Rev A 1212015

          NIOS-48037 Minor Value for the extensible attribute ldquoSiterdquo was not displayed in the Lease Selector when

          users tried to connect to an auto-provisioned member

          NIOS-50399 Enhance Enhanced the ldquoConvertrdquo button to also appear in the IPAM home page

          Severity Levels Severity Description

          Critical Core network services are significantly impacted Major Network services are impacted but there is an available workaround Moderate Some loss of secondary services or configuration abilities Minor Minor functional or UI issue Enhance An enhancement to the product

          KNOWN GENERAL ISSUES

          ID Summary

          NIOS-51323 DNS Traffic Control The appliance may return a timeout error while loading the Traffic Management tab in Grid Manager if you have configured health monitoring for a lot of DTC servers

          NIOS-51287 Cloud Network Automation Modifying resource records through the cloud API will cause extensible attribute values to be removed

          NIOS-51235 In a Multi-Grid configuration converting network connectivity for the Master Grid and its sub Grids to IPv6 only is not supported even though Grid Manager may allow you to do so

          NIOS-51134 Infoblox appliances currently do not support HP passive copper cables

          NIOS-51054 After you upgrade to NIOS 700 Infoblox recommends that you back up the configuration after you change network connectivity to a different mode (IPv4 IPv6 or IPv4 and IPv6 dual mode) Restoring an old backup by performing a forced restore may prevent some Grid members from rejoining the Grid after the restore

          NIOS-50997 In this release the appliance does not automatically create a reverse-mapping zones for 1 for DNS servers that support IPv6

          NIOS-50873 When you enable DNS and DHCP services for IPv6 only DDNS updates may not function properly for certain configurations Infoblox recommends that you do not enable DDNS updates in an IPv6-only Grid

          NIOS-50859 Creating custom IPv6 NS records and pointing a zone to a particular IPv6 name server is not supported in this release

          NIOS-50994 Cloud Network Automation When there is no tenant associated with a network or VM or if a network or VM is created by a cloud adapter but the tenant ID is not specified in the cloud API request the Name or ID column for the tenant or VM is left blank in Grid Manager which implies ldquoNArdquo or not applicable for the specified network or VM

          NIOS 701 Release Notes

          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 17 of 21 400-0579-001 Rev A 1212015

          NA Reporting When there is too much data being displayed in a graph data can overlap each other and make it difficult for viewing You can expand the graph to view specific data by stretching the graph on display However you will not be able to download the expanded graph in a PDF Workaround Right-click the expanded graph and then select This Frame -gt Print Frame from the drop-down menu to print the graph

          NIOS-49238 Network Insight Under certain circumstances deleting networks may not remove the corresponding IP helper addresses from the device configuration

          NIOS-49123 Network Insight When scheduling a discovery or port control blackout the scheduled time and time zone will always be standard time No time adjustments are made if the selected time zone is currently in daylight savings time and no adjustments are made when the time zone switches to daylight savings time

          NIOS-49107 Network Insight If a recurring port control blackout is scheduled and it includes the current time port control tasks will be delayed during the current blackout period However you may not be warned until the next blackout period If a recurring discovery blackout is scheduled and it includes the current time the Discover Now functionality may not be blocked until the next blackout period

          AUGUSTA2-1606

          Network Insight Some devices such as the Cisco 3750X may report interfaces (that are not actually functional) as available through SNMP which could cause Port Control jobs on these non-functional interfaces to fail

          NIOS-48944 Reporting When there are disconnected data points in the reporting data for reports (such as the DNS Query Rate by Query Type report) that support the stacked area panel type the stacked area that represents the disconnected data in the PDF report may not fill up accordingly and may cause it to look like a line chart when it is actually a stacked area chart Workaround Interpret the information correctly when reading the stacked area charts that contain disconnected data points

          NIOS-48912 Network Insight Is a device is not connected to another host through a network the appliance will not be able to detect the Voice VLAN information

          NIOS-48897 Network Insight Alcatel Omniswitches can operate in two modesmdashWorking mode and Certified mode Alcatel OmniSwitch 6000 devices must run in Working mode to allow Port Control jobs to work on these devices

          NIOS-48704 Reporting When you configure a search for Top Devices Denied an IP Address using Member Network View Network and CIDR as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

          NIOS-48560 Network Insight Before joining the Network Data Consolidator to the Grid use the CLI command reset net-automation database to ensure that previously discovered device information is removed from the database

          NIOS-48399 You cannot restore the existing deleted resource records from the Recycle Bin after you promote a Grid Master Candidate to the Grid Master

          NIOS-48311 On the IB-4010 appliance the maximum resource records allowed in a single signing zone is 800K not 25 of the object limit as in other platforms Exceeding this limit may result in a system restart

          NIOS-48135 bloxTools data prior to NIOS 640 cannot be restored on NIOS 611x Workaround Upgrade to NIOS 64x first to get a backup before upgrading to NIOS 611x

          NIOS 701 Release Notes

          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 18 of 21 400-0579-001 Rev A 1212015

          NIOS-48030 You may not be able to log in to the bloxTools Workflow environment if you download the snapin-workflow file from the bloxTools Community site

          NIOS-47959 Through the API and RESTful API users can add records and data without entering values for required extensible attributes Users cannot do the same through Grid Manager

          NIOS-46356 An upgrade may fail if you clone reports and searches with duplicate names for the following reports DNS Query Rate by Server DNS Daily Query Rate by Server DNS Daily Peak Hour Query Rate by Server DHCP Device Operating System Trend DHCP Top Device Operating System and Traffic Rate

          NIOS-46290 In some scenarios upgrading from NIOS 67x to NIOS 610x on an Infoblox-4030 appliance may require a manual restart to complete the upgrade

          NIOS-46102 Advanced DNS Protection You may not be able to join an independent appliance to the Grid if the appliance has threat protection service enabled and only the LAN interface configured Workaround Disable threat protection service on the appliance before joining the Grid or configure the MGMT port and enable VPN on MGMT before joining the offline appliance to the Grid

          NIOS-46051 Reporting When you configure a search for Threat Protect Event Count by Severity Trend using Member Category and Rule ID as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

          NIOS-45906 Network Insight On rare occasions when there is incomplete inaccurate or misinterpreted data in discovered spanning tree information the appliance may not be able to determine the correct switch to which an end host is attached In this scenario the appliance may display inaccurate discovered data

          NIOS-45904 Network Insight In Grid Manager the same end host on different VLANs may appear as duplicates that contain the same VLAN information

          NIOS-45872 Content in the bloxHub widget on the Status Dashboard may not be displayed in certain versions of Google Chrome Mozilla FireFox and Microsoft Internet Explorer browsers due to security updates implemented by these browsers Workarounds For Chrome Click the security shield icon next to the URL and select Load unsafe script For FireFox Click the security shield icon next to the URL and select Disable Protection on This Page from the drop-down list For IE Click Show all content in the Only secure content is displayed message bar at the bottom of the page

          NIOS-45598 Network Insight When a seed router is specified for an IP address that has already been assigned as a fixed address the IP will still be discovered even if the fixed address is excluded from discovery

          NIOS-45233 Reporting When you use Microsoft Internet Explorer 10x and disable ldquoCompatibility Viewrdquo you may not be able to view reports in the Reporting tab Workaround In the Internet Explorer 10 browser go to Tools -gt Compatibility View to enable the feature

          NIOS-45220 When you upgrade from NIOS 51r6-12 or earlier releases the Try Snapinstall option may not be available in the bloxTools environment after the upgrade Workaround Stop bloxTools service on the member console connect to the member through the CLI and execute the set bloxtools reset all command Once the reset process is complete restart the bloxTools service to access the Try Snapinstall option

          NIOS 701 Release Notes

          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 19 of 21 400-0579-001 Rev A 1212015

          VLAN-324 If you have assigned multiple VLANs to the LAN1 or LAN2 interfaces on the appliance you may receive messages about having ldquomultiple interfaces that match the same subnetrdquo during dhcpd process startups or restarts Note that these are not error messages and no actions are required

          NIOS-44055 If you use certain versions of Mozilla FireFox to run Grid Manager the auto-detected time zone feature may not function properly even if you have enabled it in your User Profile

          NIOS-43957 When you upgrade from NIOS 66x or earlier releases the email address in the SOA resource record that was entered in punycode will be converted into IDN (Internationalized Domain Name) after the upgrade Workaround Convert the IDN back to punycode using the IDN converter utility through Grid Manager

          NIOS-43569 You may not be able to view reverse-mapping zones in an internal DNS view Workaround Set the table size to 10 in User Profile log out and then log back in to the system again

          NIOS-41136 Reporting When you use certain versions of Mozilla Firefox and Google Chrome browsers on Windows 7 or Linux you may not be able to properly print reports

          NIOS-39922 On Trinzic 2200 series appliances it may take up to three minutes for the LOM (Light On Management) LED to stop blinking after you have disabled the LOM feature

          NIOS-38870 When you change the member type of an appliance from Infoblox to vNIOS the appliance might display an error message indicating that all network port settings of the vNIOS member must be changed to Automatic Workaround Through the Infoblox API use InfobloxGridMember and the functions lan_port_duplex( ) and lan_port_speed ( ) to change the network port settings for the vNIOS member

          NIOS-38579 Reporting If you have a quick filter that includes a filter criterion with report comment equals to a value that NIOS automatically translates to another value the quick filter may not function properly after an upgrade to NIOS 65 or 66 NIOS automatically translates the following ldquoIPAM Utilizationrdquo to ldquoDDI Utilizationrdquo ldquoDNS Zone Statistics per DNS Viewrdquo to ldquoDNS Statistics per DNS Viewrdquo ldquoDNS Zone Statistics per DNS Zonerdquo to ldquoDNS Statistics per Zonerdquo ldquoDNS Member QPS Trendrdquo to ldquoDNS Query Rate by Serverrdquo and ldquoDNS Queries per Second Trendrdquo to ldquoDNS Query Rate by Query Typerdquo Workaround 1 Edit the original report comment values to match the translated values For example if you have entered ldquoIPAM Utilizationrdquo in the comment field of a report change it to ldquoDDI Utilizationrdquo Workaround 2 Edit the quick filter names to match the original comment values For example if you have entered ldquoQF1rdquo as a quick filter name and ldquoIPAM Utilizationrdquo as the report comment change the quick filter name to ldquoIPAM Utilizationrdquo

          NIOS-37415 Users cannot execute Trinzic Automation Engine (TAE) if they log out of NetMRI during an active NetMRI session

          NIOS-33600 There is an issue with SafeNet HSMs in that configuration changes do not immediately take effect such as when adding a new member to an existing SafeNet HSM Group deleting a client from the HSM or making member changes You can perform a forced restart of services to apply the changes immediately

          NIOS-31864 Modifying a zone from a client increments the zonersquos serial number even if the zone contents did not change This causes unnecessary AXFRs to secondary servers and if the zone is served by a Microsoft Server that is managed in read-write mode it causes extra synchronizations as well

          NIOS 701 Release Notes

          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 20 of 21 400-0579-001 Rev A 1212015

          NIOS-31501 When a Microsoft server is the primary server for a zone and another Microsoft server is hosting the same zone as a stub zone and the NIOS appliance synchronizes DNS data with only one of these zones it will synchronize the zone as an authoritative or stub zone depending on which Microsoft server it synchronizes with first For more information please refer to KB article 17593

          NIOS-25064 (45488)

          If you configured a member DHCP server to authenticate DHCP clients with a RADIUS authentication server group and RADIUS is disabled (the server group is disabled all RADIUS servers in the group are disabled or the member DHCP server was not assigned an authentication server group) NAC filters with ldquodoes not equalrdquo rules will always match Workaround Do not disable RADIUS

          NIOS-21512 (39917)

          When you stop the DNS service of an independent appliance with temporary DNS and DHCP licenses Grid Manager displays the Restart Services panel regardless of which function you select

          NIOS-21499 (38968)

          An admin cannot display DNS views created by other admins during the same browser session To display the DNS views created by other admins you must log out and log in again

          NIOS-19853 (31668)

          Grid Manager does not display an error when you move a DNS view to a network view that contains a host record that has the same MAC address as a host record in the DNS view that is being moved

          NIOS-19144 (30208)

          Grid Manager does not sort columns correctly in the IPAM and Network list panels when the columns contain UTF-8 data

          NIOS-18163 (27831)

          The appliance allows users with read-only permission to A records to view DNSSEC resource records as well

          NIOS-17636 (26233)

          Syslog messages generated during a TFTP file transfer display the incorrect time zone

          NIOS-17513 (26080)

          Adding updating or deleting reverse zones could fail due to unsupported PTR records in the root zone

          PAPIPASS-39

          When you use Mozilla Firefox 16x 17x or Mozilla Firefox Beta 180b3 browser the hidden password in the Add Administrator Wizard of Grid Manager may disappear when you click the Password field after you have confirmed the password This is a known issue when you use Firefox browsers

          MME-154 When a NIOS user deletes a Microsoft AD domainrsquos primary zones and subzones NIOS should display a more specific message warning users about the consequences of the operation instead of the general warning message it currently displays

          MME-129 When a Microsoft admin creates a delegation on the Microsoft server and the delegation is synchronized to the NIOS appliance the glue A record of the delegation name server is synchronized to the appliance as a manually created record If on the NIOS appliance an admin changes the IP address on the NS record of the delegation name server two A glue records are generated one with the original address one with the new address NIOS retains the original glue A record because itrsquos marked as a manually created record and it can only be changed or deleted either manually on Grid Manager or through the API When synchronization occurs the Microsoft server correctly updates the existing glue A record and does not retain the original Note that NIOS retains the original A record only after the initial update If you update the A record again NIOS just updates the existing record without retaining the original

          MME-23 NIOS displays an ldquoInternal Errorrdquo message when you try to apply a quick filter for a range that equals 1 when you display a range in the IPv4 Microsoft Superscopes tab

          MME-6 If you add a hostname to the Target field of an SRV record on Grid Manager when the member synchronizes the SRV record to a Microsoft server it adds a new SRV record with the hostname instead of modifying the existing record

          NIOS 701 Release Notes

          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 21 of 21 400-0579-001 Rev A 1212015

          MSSS-11 (45296)

          When you run a discovery on a network served by Microsoft servers and Grid Manager discovers a MAC address that does not match any of the fixed addresses associated with an IP address it reports a conflict and lists the associated fixed address objects in the Related Objects table You cannot select which fixed address to resolve in the Related Objects table You can only resolve the conflict for the first address

          VNIOS-36 (41215)

          If a virtual NIOS member does not start up due to a license violation Grid Manager displays the status of the vNIOS member as ldquoonlinerunningrdquo even though the member is not online

          • INTRODUCTION
            • Supported Platforms
              • NEW FEATURES
                • NIOS 700
                  • CHANGES TO DEFAULT BEHAVIOR
                    • NIOS 700
                    • NIOS 6x Releases
                      • CHANGES TO Infoblox API and RESTful API
                        • RESTful API Deprecation and Backward Compatibility Policy
                        • NIOS 70x
                        • NIOS 6x Releases
                          • UPGRADE GUIDELINES
                            • Upgrading to NIOS 70x
                              • BEFORE YOU INSTALL
                              • ACCESSING GRID MANAGER
                              • ADDRESSED VULNERABILITIES
                              • RESOLVED ISSUES
                                • Fixed in 701
                                • Fixed in 700
                                  • KNOWN GENERAL ISSUES

            NIOS 701 Release Notes

            copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 6 of 21 400-0579-001 Rev A 1212015

            Support for IPv6 Grid

            The Infoblox appliance now supports IPv6 networking configuration in most deployments You can deploy a Grid and configure a Grid Master Grid Member reporting member and an HA pair in one of the following modes IPv4 only IPv6 only or IPv4 and IPv6 dual mode You can also configure the default communication protocol settings using IPv4 or IPv6 In addition services and functionality such as NTP service DNS Firewall and admin notifications now support both IPv4 and IPv6 addresses In addition Grid communication can now support IPv6 only and you can configure an appliance with only IPv6 addresses (no IPv4 addresses are required) Support for Microsoft Sites This release enhances the Microsoft Management solution by adding support for managing Microsoft Active Directory Sites and Subnets on Microsoft servers through Grid Manager DNS Firewall Enhancements This release adds the following enhancements for DNS Firewall

            bull Threat severity levels for RPZ zones bull Threat details in the syslog bull Categorization and filtering for DNS and Advanced DNS Protection syslog messages bull Severity level in the DNS Top RPZ Hits report

            Automated Mitigation of Phantom Domain Attacks This release provides a few CLI commands for mitigating phantom domain attacks in which a flood of queries are sent to resolve non-existent domains When phantom domain attacks happen the recursive server continues to query non-responsive servers spending valuable resources waiting for responses When resources are fully consumed the recursive server may drop legitimate queries causing serious performance issues To mitigate phantom domain attacks you can use the following CLI commands to control queries to non-responsive servers set holddown set fetches_per_server set fetches_per_zone and set recursion_query_timeout For information about these commands refer to the Infoblox CLI Guide DNSSEC Enhancement You can now add multiple cryptographic algorithms that the Grid Master uses when it generates the KSK and ZSK When you add multiple algorithms at the Grid level you can override them at the zone level By default the appliance uses RSASHA1 for both KSK and ZSK You can now add DSA RSAMD5 RSASHA1 RSASHA-256 or RSASHA-512 algorithms Configuring Fixed Addresses without Restarting DHCP Service When you configure or modify a fixed address a DHCP service restart is required by default in order for the new configuration to take effect You can now override this default behavior by enabling the appliance to take immediate action without restarting DHCP service when you configure or modify a fixed address that is outside a DHCP range You can enable this feature at the Grid or member level For Cloud Network Automation deployment this feature is automatically enabled on the Cloud Platform Appliance that has a valid Cloud Platform license installed Ignoring MAC Addresses for New Leases In addition to the UID (unique client identifier) you can now set the DHCP server to ignore the MAC address (hardware address) of a DHCP client when it places a request to the DHCP server for a new lease When you configure the appliance to ignore the MAC addresses of DHCP clients you can specify up to 10 MAC addresses to be ignored

            NIOS 701 Release Notes

            copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 7 of 21 400-0579-001 Rev A 1212015

            Name Server Groups for Delegated Zones When you configure a name server group you can now create a set of external name servers as a delegation name server group and assign it to delegated zones Specifying a single delegation name server group instead of configuring multiple name servers individually for delegated zones can significantly reduce configuration efforts Network Insight Assets for Trunk Reports Device discovery now includes in the Asset tab all hosts (physical and virtual) connected to a trunk port Reporting Enhancement This release adds the capability to email reporting search results Infoblox API and RESTful API Enhancement This release adds newly supported objects for the API and RESTful API CHANGES TO DEFAULT BEHAVIOR This section lists changes to default behavior in NIOS 70x and 6x releases NIOS 700

            bull Starting with this release you must have IPv6 addresses for both nodes in an HA pair if one of them has an IPv6 address This was optional in previous releases

            bull In previous releases when you apply a non-global DHCP option filter to a DHCP range the appliance may return option 43 in the response Starting with this release the appliance does not return option 43 in any responses when you apply a non-global DHCP option filter to a range

            NIOS 6x Releases bull In previous releases you could configure DHCP Option 60 (Vendor Class Identifier) match rules

            associated with Microsoft option_space in the Grid or member DHCP properties or DHCP option filters associated with Microsoft option_space Starting with this release these configurations are no longer supported and you cannot configure them

            bull Reporting The ldquoDomain Namerdquo and ldquoMitigation Actionrdquo filters are no longer supported in the Top RPZ Hits by Client report

            bull In previous releases the appliance added grace period to the KSK (Key Signing Key) and ZSK (Zone Signing Key) rollover periods In this release the rollover periods for a particular zone start as soon as it is signed

            bull In previous releases you could assign read-only permission for hosts in a network to restrict admins to only viewing hosts in the specified network In this release assigning read-only permission for hosts in a network does not affect the visibility of hosts in the specified network

            CHANGES TO Infoblox API and RESTful API This section lists changes made to the Infoblox API and RESTful API in NIOS releases For detailed information about the supported methods and objects refer to the latest versions of the Infoblox API Documentation and the Infoblox WAPI Documentation available through the NIOS products and on the Infoblox Support web site The latest available RESTful API version is 20

            NIOS 701 Release Notes

            copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 8 of 21 400-0579-001 Rev A 1212015

            RESTful API Deprecation and Backward Compatibility Policy This policy covers the interfaces exposed by the Infoblox RESTful API and the protocol used to communicate with it

            Unless explicitly stated in the release notes previously available RESTful API versions are intended to remain accessible and operative with later versions

            The planned deprecation of a given version of the RESTful API will normally be announced in the release notes at least one year in advance Upon deprecation the announced RESTful API version and all prior versions will no longer be supported in subsequent releases For example if the current RESTful API release is v34 and the release notes contain an announcement of the v15 deprecation v14 and v15 API requests would continue to work with later releases for one year from the announcement date After that some or all requests for these deprecated versions may not work with versions later than v15 API requests adherent to versions later than v15 (v20 for example) would continue to work with subsequent releases Infoblox seeks to avoid any deprecation that has not been announced in advance however product modifications and enhancements may affect specific API requests without a prior announcement Infoblox does not warrant that all API requests will be unaffected by future releases This policy applies to both major and minor versions of the RESTful API Infoblox reserves the right to change this policy NIOS 70x

            bull When executing a RESTful API request from version 20 and later the XML data format has been updated to accommodate tag names (used primarily in extensible attributes) that contain spaces andor invalid XML characters

            NIOS 6x Releases

            bull The RESTful API (WAPI) sample code advises using curl -k3 to access the RESTful API through SSLv3 SSLv3 is no longer supported and the ndashk3 option in curl is no longer supported To correctly use curl to access the RESTful API specify curl -k1 to force the use of TLS

            bull The following changes for keytabs have been made in the Infoblox API

            remove_datakeytab has been removed

            import_datakeytab has been removed

            import_dataupload_keytab has been added

            The API also supports multiple TSIG keys To use a keytab you must upload it and manually assign it to individual members or to DHCP you cannot complete this task in one operation If you have only one keytab you can still use the old gss_tsig members However Infoblox recommends that you switch to the new gss_tsig_keysipv6_gss_tsig_keys members

            bull The following objects have been deprecated in the Infoblox API

            InfobloxGridMSServerDNS (new object InfobloxGridMSServerServerDNS)

            status_last_updated member in InfobloxGridMSServerDNS (new object status_last_updated_ts member in epoc format)

            Though the deprecated objects will continue to function for backward compatibility purposes Infoblox recommends that you use the new objects in your new code

            bull The InfobloxGridAdminUser object password method and the InfobloxGrid object secret method have been modified to adhere to Infoblox security policies

            NIOS 701 Release Notes

            copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 9 of 21 400-0579-001 Rev A 1212015

            bull API and RESTful API After upgrading to NIOS 67x all international domain names (IDNs) in punycode are converted to Unicode (in the respective API way of encoding Unicode strings) You can use the dns_[hellip] fields in relevant objects to retrieve read-only IDNs in punycode For more information about IDNs refer to the Infoblox NIOS Administrator Guide For information about API and RESTful API refer to the Infoblox API Documentation and Infoblox RESTful API Documentation

            UPGRADE GUIDELINES Upgrading to NIOS 70x NOTES

            bull You cannot upgrade NIOS 6124 to NIOS 70x You will however be able to upgrade NIOS 6124 and later to NIOS 71x releases when they become available

            bull You cannot upgrade directly from NIOS 5x to NIOS 70x However you can first upgrade to NIOS 66x or later and then to NIOS 70x

            You cannot upgrade to NIOS 70x on the following appliances IB-250-A IB-550-A IB-1050-A IB-1550-A IB-1552-A IB-1852-A IB-2000 IB-2000-A IB-VM-250 IB-VM-550 IB-VM-1050 IB-VM-1550 IB-VM-1850 IB-VM-2000 and Trinzic Reporting TR-2000 series appliances For information about supported platforms see Supported Platforms on page 1 Note the following for IPv6 Grid support

            bull If your Grid Master is configured with an IPv6 VIP all Grid Master Candidates must also include an IPv6 VIP For an HA pair both nodes of the HA pair must have IPv6 addresses for the Grid Master and the Grid Master Candidate

            bull After you upgrade to NIOS 70x Infoblox recommends that you back up the configuration after you change network connectivity to a different mode (IPv4 IPv6 or IPv4 and IPv6 dual mode) Restoring an old backup by performing a forced restore may prevent some Grid members from rejoining the Grid after the restore

            bull IPv6-only configuration does not support the following HSM LCD NAT groups OSPF and BGP

            When you schedule a full upgrade from a previous release to NIOS 70x the following DNSSEC limitations are applicable

            bull You cannot configure new settings that are added to the authoritative zone object while the upgrade is still in progress This restriction is not applicable to future upgrades

            bull When you upgrade you can sign or unsign an authoritative zone only if the Grid Master Candidate and the associated serving members are upgraded This restriction is not applicable to future upgrades

            bull An authoritative zone can have its KSK rollover only if the Grid Master Candidate and all the serving members are upgraded This restriction is not applicable to future upgrades

            bull An authoritative zone can have its ZSK rollover by the daemon only if the Grid Master Candidate and all the serving members are upgraded This restriction is not applicable to future upgrades

            bull You cannot delete keys while the upgrade is still in progress bull You cannot update DNSSEC related parameters at the member level while the upgrade is still in

            progress Example rollover mechanism NSEC3 salt length and iterations and enable or disable automatic KSK rollover

            NIOS 701 Release Notes

            copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 10 of 21 400-0579-001 Rev A 1212015

            For Cloud Network Automation bull After upgrading to NIOS 70x you must manually select the Delegated To Cloud Usage

            and Owned By columns in the Data Management tab of Grid Manager to display relevant information This is applicable only if you have installed the Cloud Network Automation license on the Grid Master

            BEFORE YOU INSTALL To ensure that new features and enhancements operate properly and smoothly Infoblox recommends that you evaluate the capacity on your Grid and review the upgrade guidelines before you upgrade from a previous NIOS release Infoblox recommends that administrators planning to perform an upgrade from a previous release create and archive a backup of the Infoblox appliance configuration and data before upgrading You can run an upgrade test before performing the actual upgrade Infoblox recommends that you run the upgrade test so you can resolve any potential data migration issues before the upgrade Following is a list of upgrade and revert paths You can also schedule a full upgrade from these releases 700 6122 and earlier 612x releases 6117 and earlier 611x releases 610201 and 610200 61010 and earlier 610x releases 69201-LD and 69200-LD 690 6813 and earlier 68x releases 678 and earlier 67x releases 6613 and earlier 66x releases Technical Support Infoblox technical support contact information

            Telephone 1-888-463-6259 (toll-free US and Canada) +1-408-625-4200 ext 1

            E-mail supportinfobloxcom

            Web httpssupportinfobloxcom

            GUI Requirements Grid Manager supports the following operating systems and browsers You must install and enable Javascript for Grid Manager to function properly Grid Manager supports only SSL version 3 and TLS version 1 connections Infoblox recommends that you use a computer that has a 2 GHz CPU and at least 1 GB of RAM

            NIOS 701 Release Notes

            copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 11 of 21 400-0579-001 Rev A 1212015

            Infoblox supports the following browsers for Grid Manager

            OS Browser Microsoft Windows 80 and 81reg Microsoft Internet Explorerreg 11x 10x

            Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

            Microsoft Windows 7reg Microsoft Internet Explorerreg 11x 10x 9x and 8x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

            Microsoft Windows XPreg (SP2+) Microsoft Internet Explorer 7x and 8x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

            Red Hatreg Enterprise Linuxreg 7x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

            Red Hatreg Enterprise Linuxreg 6x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

            Red Hatreg Enterprise Linux 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

            Applereg Mac OS X 109x Safari 7x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

            Applereg Mac OS X 108x Safari 6x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

            Applereg Mac OS X 107x Safari 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

            Applereg Mac OS X 106x Safari 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

            NOTE Grid Manager fully supports Microsoft Internet Explorerreg 11x and 10x when you enable compatibility view in the browser Features in the Reporting tab may not function properly if you disable compatibility view In the browser go to Tools -gt Compatibility View to enable the feature When viewing Grid Manager set the screen resolution of your monitor as follows

            Minimum resolution 1280 x 768 Recommended resolution 1280 x 1024 or better

            Documentation You can download the Infoblox NIOS Administrator Guide from the appliance From Grid Manager expand the Help panel and then click Documentation -gt Admin Guide Training Training information is available at httpinterviewcentralcomeventsuploadsinfobloxloginhtml

            NIOS 701 Release Notes

            copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 12 of 21 400-0579-001 Rev A 1212015

            ACCESSING GRID MANAGER Before you log in to Grid Manager ensure that you have installed your NIOS appliance as described in the installation guide or user guide that shipped with your product and configured it accordingly To log in to Grid Manager

            1 Open an Internet browser window and enter httpsltIPv4 address or hostname of your NIOS appliancegt or https[IPv6 address] of your NIOS appliance The Grid Manager login page appears

            2 Enter your user name and password and then click Login or press Enter The default user name is admin and password is infoblox

            3 Read the Infoblox End-User License Agreement and click I Accept to proceed Grid Manager displays the Dashboard your home page in Grid Manager

            ADDRESSED VULNERABILITIES This section lists security vulnerabilities that were addressed in the past 12 months For vulnerabilities that are not listed in this section refer to Infoblox KB 2899 For additional information about these vulnerabilities including their severities please refer to the National Vulnerability Database (NVD) at httpnvdnistgov The Infoblox Support website at httpssupportinfobloxcom also provides more information including vulnerabilities that do not affect Infoblox appliances CERT VULNERABILITY NOTE CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation CERT VULNERABILITY NOTE CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet CERT VULNERABILITY NOTE CVE-2014-3566 SSL3 is vulnerable to man-in-the-middle-attacks SSL3 is disabled in NIOS and connections must use TLSv1 (which is already used by all supported browsers)

            CERT VULNERABILITY NOTE CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

            CERT VULNERABILITY NOTE CVE-2014-7187 Off-by-one error in the read_token_word function in parsey in GNU BASH through v 43 allowed remote attackers to cause a denial of service (out-of-bounds array access and application crash) or possibly an unspecified impact through deeply nested for loops (also known as the word_lineno issue)

            CERT VULNERABILITY NOTE CVE-2014-7186 The redirection implementation in parsey in GNU BASH through v 43 allowed remote attackers to cause a denial of service (out-of-bounds array access and application crash) or possibly an unspecified impact through the redir_stack issue

            CERT VULNERABILITY NOTE CVE-2014-6271 CVE-3014-6277 CVE-2014-6278 AND CVE-2014-7169 GNU Bash through v 43 processed trailing strings after function definitions in the values of environment variables which allowed remote attackers to execute arbitrary code via a crafted environment (also known as the ShellShock vulnerability)

            NIOS 701 Release Notes

            copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 13 of 21 400-0579-001 Rev A 1212015

            CERT VULNERABILITY NOTE CVE-2014-3470 Enabling anonymous ECDH cipher suites on TLS clients could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0224 A specially crafted handshake packet could force the use of weak keying material in the SSLTLS clients allowing a man-in-the-middle (MITM) attack to decrypt and modify traffic between a client and a server CERT VULNERABILITY NOTE CVE-2014-0221 Remote attackers could utilize DTLS hello message in an invalid DTLS handshake to cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0198 Enabling SSL_MODE_RELEASE_BUFFERS failed to manage buffer pointer during certain recursive calls that could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0195 Remote attackers could trigger buffer overrun attack through invalid DTLS fragments to an OpenSSL DTLS client or server resulting in a denial of service CERT VULNERABILITY NOTE CVE-2014-0591 A crafted query against an NSEC3-signed zone could cause the named process to terminate RESOLVED ISSUES The following issues were reported in previous NIOS releases and resolved in this release The resolved issues are listed by severity For descriptions of the severity levels refer to Severity Levels on page 16 Fixed in 701

            ID Severity Summary

            NIOS-51535 Major An IPv6 address configured before NIOS 640 was not properly preserved during an upgrade to NIOS 700 which caused an error during product initialization

            Fixed in 700

            ID Severity Summary

            NIOS-50432 Critical Addressed zone journal file size issues that caused DNS service to slow down

            NIOS-50295 Critical After a DIW import there were some missing delegations and records in the Grid data set

            NIOS-50162 NIOS-50124

            Critical Under certain circumstances intermittent DNS service interruptions occurred

            ID Severity Summary

            NIOS-51186 Major DNS failed to respond to some queries due to new limits exposed by CVE-2014-8500

            NIOS-51051 Major DNS service interruptions occurred after changing RPZ records

            NIOS 701 Release Notes

            copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 14 of 21 400-0579-001 Rev A 1212015

            NIOS-50894 Major Updated the Infoblox NIOS Administrator Guide to include information about virtual TFTP root is supported only for file downloads but not for file uploads using TFTP client

            NIOS-50784 Major Addressed the following OpenVPN vulnerability CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet

            NIOS-50532 Major Addressed the following vulnerabilities CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation

            NIOS-50617 NIOS-49810

            Major Grid Manager inappropriately marked IPv6 leases as having invalid MAC addresses

            NIOS-50575 Major NIOS did not show the root domain for Microsoft servers belonging to two Domains in the same Forest

            NIOS-50567 Major DIW failed to handle common CNAME records in different DNS views

            NIOS-50453 Major Added information about HA Grid Master providing NTP service through VIP to the Infoblox NIOS Administrator Guide

            NIOS-50402 Major Under certain circumstances NIOS returned option 43 in the response when users applied a non-global IPv4 option filter to a DHCP range

            NIOS-50250 Major Unable to remove a Grid from the Master Grid

            NIOS-50208 Major On some occasions the inheritance state for inherited extensible attributes was displayed as ldquooverriddenrdquo instead of ldquoinheritedrdquo

            NIOS-50199 Major Unable to modify a DHCP scope that was synchronized from a Microsoft DHCP failover partner

            NIOS-50171 Major Users could not convert a lease to a fixed address without the ldquoNetwork Discoveryrdquo permission which was not required

            NIOS-50137 Major VLAN tagging was not functional properly on the HA interface

            NIOS-50112 Major High CPU usage on Captive Portal caused by the ldquoomshellrdquo process

            NIOS-50081 Major Unable to add the same IPv6 loopback address on other Grid members when the IPv6 address is already configured on the Grid Master

            NIOS-50057 Major DHCP service interruptions occurred after an upgrade due to issues related to disabled Grid members in a MAC address filter

            NIOS-50052 Major Addressed the following SSL 30 vulnerability CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

            NIOS-49962 Major Unable to edit and save Upgrade Schedule

            NIOS-49941 Major In a Multi-Grid configuration the Master Grid experienced high swap usage while processing a lot of data

            NIOS-49935 Major Under certain circumstances exporting visible data from Grid Manager could fail for a zone

            NIOS 701 Release Notes

            copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 15 of 21 400-0579-001 Rev A 1212015

            NIOS-49934 Major API On rare occasions searching with return_methods could result in incorrect PAPI results

            NIOS-49847 Major The appliance returned an error when users tried to disable GSS-TSIG and remove the keys

            NIOS-49826 Major Could not start DNS service on the Grid Secondary for a zone that had an external Primary while moving the LAN2 IP address from one member to the other

            NIOS-49809 Major In a network template users could not save values for an extensible attribute that was a ldquolistrdquo type

            NIOS-49735 Major The status of a Microsoft server was ldquoConnectingrdquo even when synchronization was in progress

            NIOS-49505 Major High disk space usage was observed after enabling ldquoCapture DNS Queriesrdquo and ldquoCapture DNS Responsesrdquo

            NIOS-49473 Major On rare occasions the Grid Master rebooted and went offline

            NIOS-49349 Major The infobloxlog captured bloxTools user password in plain text

            NIOS-49339 Major Grid Manager access was denied due to a missing object in the backup file

            NIOS-49137 Major Advanced DNS Protection An unexpected HA failover occurred due to a general protection fault

            NIOS-48437 Major DNS latency for DNS responses from cache was higher than usual for a duration of a couple seconds

            NIOS-48009 Major A schedule upgrade did not function properly if the HA Grid Master had not replicated the schedule to the passive node before the upgrade started

            NIOS-47994 Major DHCP service failed to start due to invalid DHCP option spaces defined in the DHCP configuration file

            NIOS-50571 Minor Added descriptions about VLAN tag and DSCP support for TE-1400 series appliances to the Infoblox NIOS Administrator Guide

            NIOS-50466 Minor DNS service startup took longer than expected due to journal file fragmentation

            NIOS-50430 Minor Redefined the description for ldquoinfoblox-deny-rpzrdquo in the Infoblox NIOS Administrator Guide

            NIOS-50401 Minor When associating a network with a Microsoft site an error message was displayed in the background instead of inside the editor

            NIOS-50366 Minor Updated the CSV Import Reference to include the file format for ldquoresponsepolicyipaddressrdquo objects

            NIOS-50267 Minor Unable to perform a discovery for a Microsoft managed subnet

            NIOS-49986 Minor Updated IP addresses used in example in the Infoblox NIOS Administrator Guide

            NIOS-49838 Minor Could not transfer support bundle using the transfer_supportbundle command

            NIOS-49816 Minor The Discoverer field value was truncated in the IP MAP viewer under the Discovered Data tab

            NIOS-49787 Minor The appliance logged excessive debugging messages

            NIOS 701 Release Notes

            copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 16 of 21 400-0579-001 Rev A 1212015

            NIOS-48037 Minor Value for the extensible attribute ldquoSiterdquo was not displayed in the Lease Selector when

            users tried to connect to an auto-provisioned member

            NIOS-50399 Enhance Enhanced the ldquoConvertrdquo button to also appear in the IPAM home page

            Severity Levels Severity Description

            Critical Core network services are significantly impacted Major Network services are impacted but there is an available workaround Moderate Some loss of secondary services or configuration abilities Minor Minor functional or UI issue Enhance An enhancement to the product

            KNOWN GENERAL ISSUES

            ID Summary

            NIOS-51323 DNS Traffic Control The appliance may return a timeout error while loading the Traffic Management tab in Grid Manager if you have configured health monitoring for a lot of DTC servers

            NIOS-51287 Cloud Network Automation Modifying resource records through the cloud API will cause extensible attribute values to be removed

            NIOS-51235 In a Multi-Grid configuration converting network connectivity for the Master Grid and its sub Grids to IPv6 only is not supported even though Grid Manager may allow you to do so

            NIOS-51134 Infoblox appliances currently do not support HP passive copper cables

            NIOS-51054 After you upgrade to NIOS 700 Infoblox recommends that you back up the configuration after you change network connectivity to a different mode (IPv4 IPv6 or IPv4 and IPv6 dual mode) Restoring an old backup by performing a forced restore may prevent some Grid members from rejoining the Grid after the restore

            NIOS-50997 In this release the appliance does not automatically create a reverse-mapping zones for 1 for DNS servers that support IPv6

            NIOS-50873 When you enable DNS and DHCP services for IPv6 only DDNS updates may not function properly for certain configurations Infoblox recommends that you do not enable DDNS updates in an IPv6-only Grid

            NIOS-50859 Creating custom IPv6 NS records and pointing a zone to a particular IPv6 name server is not supported in this release

            NIOS-50994 Cloud Network Automation When there is no tenant associated with a network or VM or if a network or VM is created by a cloud adapter but the tenant ID is not specified in the cloud API request the Name or ID column for the tenant or VM is left blank in Grid Manager which implies ldquoNArdquo or not applicable for the specified network or VM

            NIOS 701 Release Notes

            copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 17 of 21 400-0579-001 Rev A 1212015

            NA Reporting When there is too much data being displayed in a graph data can overlap each other and make it difficult for viewing You can expand the graph to view specific data by stretching the graph on display However you will not be able to download the expanded graph in a PDF Workaround Right-click the expanded graph and then select This Frame -gt Print Frame from the drop-down menu to print the graph

            NIOS-49238 Network Insight Under certain circumstances deleting networks may not remove the corresponding IP helper addresses from the device configuration

            NIOS-49123 Network Insight When scheduling a discovery or port control blackout the scheduled time and time zone will always be standard time No time adjustments are made if the selected time zone is currently in daylight savings time and no adjustments are made when the time zone switches to daylight savings time

            NIOS-49107 Network Insight If a recurring port control blackout is scheduled and it includes the current time port control tasks will be delayed during the current blackout period However you may not be warned until the next blackout period If a recurring discovery blackout is scheduled and it includes the current time the Discover Now functionality may not be blocked until the next blackout period

            AUGUSTA2-1606

            Network Insight Some devices such as the Cisco 3750X may report interfaces (that are not actually functional) as available through SNMP which could cause Port Control jobs on these non-functional interfaces to fail

            NIOS-48944 Reporting When there are disconnected data points in the reporting data for reports (such as the DNS Query Rate by Query Type report) that support the stacked area panel type the stacked area that represents the disconnected data in the PDF report may not fill up accordingly and may cause it to look like a line chart when it is actually a stacked area chart Workaround Interpret the information correctly when reading the stacked area charts that contain disconnected data points

            NIOS-48912 Network Insight Is a device is not connected to another host through a network the appliance will not be able to detect the Voice VLAN information

            NIOS-48897 Network Insight Alcatel Omniswitches can operate in two modesmdashWorking mode and Certified mode Alcatel OmniSwitch 6000 devices must run in Working mode to allow Port Control jobs to work on these devices

            NIOS-48704 Reporting When you configure a search for Top Devices Denied an IP Address using Member Network View Network and CIDR as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

            NIOS-48560 Network Insight Before joining the Network Data Consolidator to the Grid use the CLI command reset net-automation database to ensure that previously discovered device information is removed from the database

            NIOS-48399 You cannot restore the existing deleted resource records from the Recycle Bin after you promote a Grid Master Candidate to the Grid Master

            NIOS-48311 On the IB-4010 appliance the maximum resource records allowed in a single signing zone is 800K not 25 of the object limit as in other platforms Exceeding this limit may result in a system restart

            NIOS-48135 bloxTools data prior to NIOS 640 cannot be restored on NIOS 611x Workaround Upgrade to NIOS 64x first to get a backup before upgrading to NIOS 611x

            NIOS 701 Release Notes

            copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 18 of 21 400-0579-001 Rev A 1212015

            NIOS-48030 You may not be able to log in to the bloxTools Workflow environment if you download the snapin-workflow file from the bloxTools Community site

            NIOS-47959 Through the API and RESTful API users can add records and data without entering values for required extensible attributes Users cannot do the same through Grid Manager

            NIOS-46356 An upgrade may fail if you clone reports and searches with duplicate names for the following reports DNS Query Rate by Server DNS Daily Query Rate by Server DNS Daily Peak Hour Query Rate by Server DHCP Device Operating System Trend DHCP Top Device Operating System and Traffic Rate

            NIOS-46290 In some scenarios upgrading from NIOS 67x to NIOS 610x on an Infoblox-4030 appliance may require a manual restart to complete the upgrade

            NIOS-46102 Advanced DNS Protection You may not be able to join an independent appliance to the Grid if the appliance has threat protection service enabled and only the LAN interface configured Workaround Disable threat protection service on the appliance before joining the Grid or configure the MGMT port and enable VPN on MGMT before joining the offline appliance to the Grid

            NIOS-46051 Reporting When you configure a search for Threat Protect Event Count by Severity Trend using Member Category and Rule ID as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

            NIOS-45906 Network Insight On rare occasions when there is incomplete inaccurate or misinterpreted data in discovered spanning tree information the appliance may not be able to determine the correct switch to which an end host is attached In this scenario the appliance may display inaccurate discovered data

            NIOS-45904 Network Insight In Grid Manager the same end host on different VLANs may appear as duplicates that contain the same VLAN information

            NIOS-45872 Content in the bloxHub widget on the Status Dashboard may not be displayed in certain versions of Google Chrome Mozilla FireFox and Microsoft Internet Explorer browsers due to security updates implemented by these browsers Workarounds For Chrome Click the security shield icon next to the URL and select Load unsafe script For FireFox Click the security shield icon next to the URL and select Disable Protection on This Page from the drop-down list For IE Click Show all content in the Only secure content is displayed message bar at the bottom of the page

            NIOS-45598 Network Insight When a seed router is specified for an IP address that has already been assigned as a fixed address the IP will still be discovered even if the fixed address is excluded from discovery

            NIOS-45233 Reporting When you use Microsoft Internet Explorer 10x and disable ldquoCompatibility Viewrdquo you may not be able to view reports in the Reporting tab Workaround In the Internet Explorer 10 browser go to Tools -gt Compatibility View to enable the feature

            NIOS-45220 When you upgrade from NIOS 51r6-12 or earlier releases the Try Snapinstall option may not be available in the bloxTools environment after the upgrade Workaround Stop bloxTools service on the member console connect to the member through the CLI and execute the set bloxtools reset all command Once the reset process is complete restart the bloxTools service to access the Try Snapinstall option

            NIOS 701 Release Notes

            copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 19 of 21 400-0579-001 Rev A 1212015

            VLAN-324 If you have assigned multiple VLANs to the LAN1 or LAN2 interfaces on the appliance you may receive messages about having ldquomultiple interfaces that match the same subnetrdquo during dhcpd process startups or restarts Note that these are not error messages and no actions are required

            NIOS-44055 If you use certain versions of Mozilla FireFox to run Grid Manager the auto-detected time zone feature may not function properly even if you have enabled it in your User Profile

            NIOS-43957 When you upgrade from NIOS 66x or earlier releases the email address in the SOA resource record that was entered in punycode will be converted into IDN (Internationalized Domain Name) after the upgrade Workaround Convert the IDN back to punycode using the IDN converter utility through Grid Manager

            NIOS-43569 You may not be able to view reverse-mapping zones in an internal DNS view Workaround Set the table size to 10 in User Profile log out and then log back in to the system again

            NIOS-41136 Reporting When you use certain versions of Mozilla Firefox and Google Chrome browsers on Windows 7 or Linux you may not be able to properly print reports

            NIOS-39922 On Trinzic 2200 series appliances it may take up to three minutes for the LOM (Light On Management) LED to stop blinking after you have disabled the LOM feature

            NIOS-38870 When you change the member type of an appliance from Infoblox to vNIOS the appliance might display an error message indicating that all network port settings of the vNIOS member must be changed to Automatic Workaround Through the Infoblox API use InfobloxGridMember and the functions lan_port_duplex( ) and lan_port_speed ( ) to change the network port settings for the vNIOS member

            NIOS-38579 Reporting If you have a quick filter that includes a filter criterion with report comment equals to a value that NIOS automatically translates to another value the quick filter may not function properly after an upgrade to NIOS 65 or 66 NIOS automatically translates the following ldquoIPAM Utilizationrdquo to ldquoDDI Utilizationrdquo ldquoDNS Zone Statistics per DNS Viewrdquo to ldquoDNS Statistics per DNS Viewrdquo ldquoDNS Zone Statistics per DNS Zonerdquo to ldquoDNS Statistics per Zonerdquo ldquoDNS Member QPS Trendrdquo to ldquoDNS Query Rate by Serverrdquo and ldquoDNS Queries per Second Trendrdquo to ldquoDNS Query Rate by Query Typerdquo Workaround 1 Edit the original report comment values to match the translated values For example if you have entered ldquoIPAM Utilizationrdquo in the comment field of a report change it to ldquoDDI Utilizationrdquo Workaround 2 Edit the quick filter names to match the original comment values For example if you have entered ldquoQF1rdquo as a quick filter name and ldquoIPAM Utilizationrdquo as the report comment change the quick filter name to ldquoIPAM Utilizationrdquo

            NIOS-37415 Users cannot execute Trinzic Automation Engine (TAE) if they log out of NetMRI during an active NetMRI session

            NIOS-33600 There is an issue with SafeNet HSMs in that configuration changes do not immediately take effect such as when adding a new member to an existing SafeNet HSM Group deleting a client from the HSM or making member changes You can perform a forced restart of services to apply the changes immediately

            NIOS-31864 Modifying a zone from a client increments the zonersquos serial number even if the zone contents did not change This causes unnecessary AXFRs to secondary servers and if the zone is served by a Microsoft Server that is managed in read-write mode it causes extra synchronizations as well

            NIOS 701 Release Notes

            copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 20 of 21 400-0579-001 Rev A 1212015

            NIOS-31501 When a Microsoft server is the primary server for a zone and another Microsoft server is hosting the same zone as a stub zone and the NIOS appliance synchronizes DNS data with only one of these zones it will synchronize the zone as an authoritative or stub zone depending on which Microsoft server it synchronizes with first For more information please refer to KB article 17593

            NIOS-25064 (45488)

            If you configured a member DHCP server to authenticate DHCP clients with a RADIUS authentication server group and RADIUS is disabled (the server group is disabled all RADIUS servers in the group are disabled or the member DHCP server was not assigned an authentication server group) NAC filters with ldquodoes not equalrdquo rules will always match Workaround Do not disable RADIUS

            NIOS-21512 (39917)

            When you stop the DNS service of an independent appliance with temporary DNS and DHCP licenses Grid Manager displays the Restart Services panel regardless of which function you select

            NIOS-21499 (38968)

            An admin cannot display DNS views created by other admins during the same browser session To display the DNS views created by other admins you must log out and log in again

            NIOS-19853 (31668)

            Grid Manager does not display an error when you move a DNS view to a network view that contains a host record that has the same MAC address as a host record in the DNS view that is being moved

            NIOS-19144 (30208)

            Grid Manager does not sort columns correctly in the IPAM and Network list panels when the columns contain UTF-8 data

            NIOS-18163 (27831)

            The appliance allows users with read-only permission to A records to view DNSSEC resource records as well

            NIOS-17636 (26233)

            Syslog messages generated during a TFTP file transfer display the incorrect time zone

            NIOS-17513 (26080)

            Adding updating or deleting reverse zones could fail due to unsupported PTR records in the root zone

            PAPIPASS-39

            When you use Mozilla Firefox 16x 17x or Mozilla Firefox Beta 180b3 browser the hidden password in the Add Administrator Wizard of Grid Manager may disappear when you click the Password field after you have confirmed the password This is a known issue when you use Firefox browsers

            MME-154 When a NIOS user deletes a Microsoft AD domainrsquos primary zones and subzones NIOS should display a more specific message warning users about the consequences of the operation instead of the general warning message it currently displays

            MME-129 When a Microsoft admin creates a delegation on the Microsoft server and the delegation is synchronized to the NIOS appliance the glue A record of the delegation name server is synchronized to the appliance as a manually created record If on the NIOS appliance an admin changes the IP address on the NS record of the delegation name server two A glue records are generated one with the original address one with the new address NIOS retains the original glue A record because itrsquos marked as a manually created record and it can only be changed or deleted either manually on Grid Manager or through the API When synchronization occurs the Microsoft server correctly updates the existing glue A record and does not retain the original Note that NIOS retains the original A record only after the initial update If you update the A record again NIOS just updates the existing record without retaining the original

            MME-23 NIOS displays an ldquoInternal Errorrdquo message when you try to apply a quick filter for a range that equals 1 when you display a range in the IPv4 Microsoft Superscopes tab

            MME-6 If you add a hostname to the Target field of an SRV record on Grid Manager when the member synchronizes the SRV record to a Microsoft server it adds a new SRV record with the hostname instead of modifying the existing record

            NIOS 701 Release Notes

            copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 21 of 21 400-0579-001 Rev A 1212015

            MSSS-11 (45296)

            When you run a discovery on a network served by Microsoft servers and Grid Manager discovers a MAC address that does not match any of the fixed addresses associated with an IP address it reports a conflict and lists the associated fixed address objects in the Related Objects table You cannot select which fixed address to resolve in the Related Objects table You can only resolve the conflict for the first address

            VNIOS-36 (41215)

            If a virtual NIOS member does not start up due to a license violation Grid Manager displays the status of the vNIOS member as ldquoonlinerunningrdquo even though the member is not online

            • INTRODUCTION
              • Supported Platforms
                • NEW FEATURES
                  • NIOS 700
                    • CHANGES TO DEFAULT BEHAVIOR
                      • NIOS 700
                      • NIOS 6x Releases
                        • CHANGES TO Infoblox API and RESTful API
                          • RESTful API Deprecation and Backward Compatibility Policy
                          • NIOS 70x
                          • NIOS 6x Releases
                            • UPGRADE GUIDELINES
                              • Upgrading to NIOS 70x
                                • BEFORE YOU INSTALL
                                • ACCESSING GRID MANAGER
                                • ADDRESSED VULNERABILITIES
                                • RESOLVED ISSUES
                                  • Fixed in 701
                                  • Fixed in 700
                                    • KNOWN GENERAL ISSUES

              NIOS 701 Release Notes

              copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 7 of 21 400-0579-001 Rev A 1212015

              Name Server Groups for Delegated Zones When you configure a name server group you can now create a set of external name servers as a delegation name server group and assign it to delegated zones Specifying a single delegation name server group instead of configuring multiple name servers individually for delegated zones can significantly reduce configuration efforts Network Insight Assets for Trunk Reports Device discovery now includes in the Asset tab all hosts (physical and virtual) connected to a trunk port Reporting Enhancement This release adds the capability to email reporting search results Infoblox API and RESTful API Enhancement This release adds newly supported objects for the API and RESTful API CHANGES TO DEFAULT BEHAVIOR This section lists changes to default behavior in NIOS 70x and 6x releases NIOS 700

              bull Starting with this release you must have IPv6 addresses for both nodes in an HA pair if one of them has an IPv6 address This was optional in previous releases

              bull In previous releases when you apply a non-global DHCP option filter to a DHCP range the appliance may return option 43 in the response Starting with this release the appliance does not return option 43 in any responses when you apply a non-global DHCP option filter to a range

              NIOS 6x Releases bull In previous releases you could configure DHCP Option 60 (Vendor Class Identifier) match rules

              associated with Microsoft option_space in the Grid or member DHCP properties or DHCP option filters associated with Microsoft option_space Starting with this release these configurations are no longer supported and you cannot configure them

              bull Reporting The ldquoDomain Namerdquo and ldquoMitigation Actionrdquo filters are no longer supported in the Top RPZ Hits by Client report

              bull In previous releases the appliance added grace period to the KSK (Key Signing Key) and ZSK (Zone Signing Key) rollover periods In this release the rollover periods for a particular zone start as soon as it is signed

              bull In previous releases you could assign read-only permission for hosts in a network to restrict admins to only viewing hosts in the specified network In this release assigning read-only permission for hosts in a network does not affect the visibility of hosts in the specified network

              CHANGES TO Infoblox API and RESTful API This section lists changes made to the Infoblox API and RESTful API in NIOS releases For detailed information about the supported methods and objects refer to the latest versions of the Infoblox API Documentation and the Infoblox WAPI Documentation available through the NIOS products and on the Infoblox Support web site The latest available RESTful API version is 20

              NIOS 701 Release Notes

              copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 8 of 21 400-0579-001 Rev A 1212015

              RESTful API Deprecation and Backward Compatibility Policy This policy covers the interfaces exposed by the Infoblox RESTful API and the protocol used to communicate with it

              Unless explicitly stated in the release notes previously available RESTful API versions are intended to remain accessible and operative with later versions

              The planned deprecation of a given version of the RESTful API will normally be announced in the release notes at least one year in advance Upon deprecation the announced RESTful API version and all prior versions will no longer be supported in subsequent releases For example if the current RESTful API release is v34 and the release notes contain an announcement of the v15 deprecation v14 and v15 API requests would continue to work with later releases for one year from the announcement date After that some or all requests for these deprecated versions may not work with versions later than v15 API requests adherent to versions later than v15 (v20 for example) would continue to work with subsequent releases Infoblox seeks to avoid any deprecation that has not been announced in advance however product modifications and enhancements may affect specific API requests without a prior announcement Infoblox does not warrant that all API requests will be unaffected by future releases This policy applies to both major and minor versions of the RESTful API Infoblox reserves the right to change this policy NIOS 70x

              bull When executing a RESTful API request from version 20 and later the XML data format has been updated to accommodate tag names (used primarily in extensible attributes) that contain spaces andor invalid XML characters

              NIOS 6x Releases

              bull The RESTful API (WAPI) sample code advises using curl -k3 to access the RESTful API through SSLv3 SSLv3 is no longer supported and the ndashk3 option in curl is no longer supported To correctly use curl to access the RESTful API specify curl -k1 to force the use of TLS

              bull The following changes for keytabs have been made in the Infoblox API

              remove_datakeytab has been removed

              import_datakeytab has been removed

              import_dataupload_keytab has been added

              The API also supports multiple TSIG keys To use a keytab you must upload it and manually assign it to individual members or to DHCP you cannot complete this task in one operation If you have only one keytab you can still use the old gss_tsig members However Infoblox recommends that you switch to the new gss_tsig_keysipv6_gss_tsig_keys members

              bull The following objects have been deprecated in the Infoblox API

              InfobloxGridMSServerDNS (new object InfobloxGridMSServerServerDNS)

              status_last_updated member in InfobloxGridMSServerDNS (new object status_last_updated_ts member in epoc format)

              Though the deprecated objects will continue to function for backward compatibility purposes Infoblox recommends that you use the new objects in your new code

              bull The InfobloxGridAdminUser object password method and the InfobloxGrid object secret method have been modified to adhere to Infoblox security policies

              NIOS 701 Release Notes

              copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 9 of 21 400-0579-001 Rev A 1212015

              bull API and RESTful API After upgrading to NIOS 67x all international domain names (IDNs) in punycode are converted to Unicode (in the respective API way of encoding Unicode strings) You can use the dns_[hellip] fields in relevant objects to retrieve read-only IDNs in punycode For more information about IDNs refer to the Infoblox NIOS Administrator Guide For information about API and RESTful API refer to the Infoblox API Documentation and Infoblox RESTful API Documentation

              UPGRADE GUIDELINES Upgrading to NIOS 70x NOTES

              bull You cannot upgrade NIOS 6124 to NIOS 70x You will however be able to upgrade NIOS 6124 and later to NIOS 71x releases when they become available

              bull You cannot upgrade directly from NIOS 5x to NIOS 70x However you can first upgrade to NIOS 66x or later and then to NIOS 70x

              You cannot upgrade to NIOS 70x on the following appliances IB-250-A IB-550-A IB-1050-A IB-1550-A IB-1552-A IB-1852-A IB-2000 IB-2000-A IB-VM-250 IB-VM-550 IB-VM-1050 IB-VM-1550 IB-VM-1850 IB-VM-2000 and Trinzic Reporting TR-2000 series appliances For information about supported platforms see Supported Platforms on page 1 Note the following for IPv6 Grid support

              bull If your Grid Master is configured with an IPv6 VIP all Grid Master Candidates must also include an IPv6 VIP For an HA pair both nodes of the HA pair must have IPv6 addresses for the Grid Master and the Grid Master Candidate

              bull After you upgrade to NIOS 70x Infoblox recommends that you back up the configuration after you change network connectivity to a different mode (IPv4 IPv6 or IPv4 and IPv6 dual mode) Restoring an old backup by performing a forced restore may prevent some Grid members from rejoining the Grid after the restore

              bull IPv6-only configuration does not support the following HSM LCD NAT groups OSPF and BGP

              When you schedule a full upgrade from a previous release to NIOS 70x the following DNSSEC limitations are applicable

              bull You cannot configure new settings that are added to the authoritative zone object while the upgrade is still in progress This restriction is not applicable to future upgrades

              bull When you upgrade you can sign or unsign an authoritative zone only if the Grid Master Candidate and the associated serving members are upgraded This restriction is not applicable to future upgrades

              bull An authoritative zone can have its KSK rollover only if the Grid Master Candidate and all the serving members are upgraded This restriction is not applicable to future upgrades

              bull An authoritative zone can have its ZSK rollover by the daemon only if the Grid Master Candidate and all the serving members are upgraded This restriction is not applicable to future upgrades

              bull You cannot delete keys while the upgrade is still in progress bull You cannot update DNSSEC related parameters at the member level while the upgrade is still in

              progress Example rollover mechanism NSEC3 salt length and iterations and enable or disable automatic KSK rollover

              NIOS 701 Release Notes

              copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 10 of 21 400-0579-001 Rev A 1212015

              For Cloud Network Automation bull After upgrading to NIOS 70x you must manually select the Delegated To Cloud Usage

              and Owned By columns in the Data Management tab of Grid Manager to display relevant information This is applicable only if you have installed the Cloud Network Automation license on the Grid Master

              BEFORE YOU INSTALL To ensure that new features and enhancements operate properly and smoothly Infoblox recommends that you evaluate the capacity on your Grid and review the upgrade guidelines before you upgrade from a previous NIOS release Infoblox recommends that administrators planning to perform an upgrade from a previous release create and archive a backup of the Infoblox appliance configuration and data before upgrading You can run an upgrade test before performing the actual upgrade Infoblox recommends that you run the upgrade test so you can resolve any potential data migration issues before the upgrade Following is a list of upgrade and revert paths You can also schedule a full upgrade from these releases 700 6122 and earlier 612x releases 6117 and earlier 611x releases 610201 and 610200 61010 and earlier 610x releases 69201-LD and 69200-LD 690 6813 and earlier 68x releases 678 and earlier 67x releases 6613 and earlier 66x releases Technical Support Infoblox technical support contact information

              Telephone 1-888-463-6259 (toll-free US and Canada) +1-408-625-4200 ext 1

              E-mail supportinfobloxcom

              Web httpssupportinfobloxcom

              GUI Requirements Grid Manager supports the following operating systems and browsers You must install and enable Javascript for Grid Manager to function properly Grid Manager supports only SSL version 3 and TLS version 1 connections Infoblox recommends that you use a computer that has a 2 GHz CPU and at least 1 GB of RAM

              NIOS 701 Release Notes

              copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 11 of 21 400-0579-001 Rev A 1212015

              Infoblox supports the following browsers for Grid Manager

              OS Browser Microsoft Windows 80 and 81reg Microsoft Internet Explorerreg 11x 10x

              Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

              Microsoft Windows 7reg Microsoft Internet Explorerreg 11x 10x 9x and 8x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

              Microsoft Windows XPreg (SP2+) Microsoft Internet Explorer 7x and 8x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

              Red Hatreg Enterprise Linuxreg 7x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

              Red Hatreg Enterprise Linuxreg 6x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

              Red Hatreg Enterprise Linux 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

              Applereg Mac OS X 109x Safari 7x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

              Applereg Mac OS X 108x Safari 6x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

              Applereg Mac OS X 107x Safari 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

              Applereg Mac OS X 106x Safari 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

              NOTE Grid Manager fully supports Microsoft Internet Explorerreg 11x and 10x when you enable compatibility view in the browser Features in the Reporting tab may not function properly if you disable compatibility view In the browser go to Tools -gt Compatibility View to enable the feature When viewing Grid Manager set the screen resolution of your monitor as follows

              Minimum resolution 1280 x 768 Recommended resolution 1280 x 1024 or better

              Documentation You can download the Infoblox NIOS Administrator Guide from the appliance From Grid Manager expand the Help panel and then click Documentation -gt Admin Guide Training Training information is available at httpinterviewcentralcomeventsuploadsinfobloxloginhtml

              NIOS 701 Release Notes

              copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 12 of 21 400-0579-001 Rev A 1212015

              ACCESSING GRID MANAGER Before you log in to Grid Manager ensure that you have installed your NIOS appliance as described in the installation guide or user guide that shipped with your product and configured it accordingly To log in to Grid Manager

              1 Open an Internet browser window and enter httpsltIPv4 address or hostname of your NIOS appliancegt or https[IPv6 address] of your NIOS appliance The Grid Manager login page appears

              2 Enter your user name and password and then click Login or press Enter The default user name is admin and password is infoblox

              3 Read the Infoblox End-User License Agreement and click I Accept to proceed Grid Manager displays the Dashboard your home page in Grid Manager

              ADDRESSED VULNERABILITIES This section lists security vulnerabilities that were addressed in the past 12 months For vulnerabilities that are not listed in this section refer to Infoblox KB 2899 For additional information about these vulnerabilities including their severities please refer to the National Vulnerability Database (NVD) at httpnvdnistgov The Infoblox Support website at httpssupportinfobloxcom also provides more information including vulnerabilities that do not affect Infoblox appliances CERT VULNERABILITY NOTE CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation CERT VULNERABILITY NOTE CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet CERT VULNERABILITY NOTE CVE-2014-3566 SSL3 is vulnerable to man-in-the-middle-attacks SSL3 is disabled in NIOS and connections must use TLSv1 (which is already used by all supported browsers)

              CERT VULNERABILITY NOTE CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

              CERT VULNERABILITY NOTE CVE-2014-7187 Off-by-one error in the read_token_word function in parsey in GNU BASH through v 43 allowed remote attackers to cause a denial of service (out-of-bounds array access and application crash) or possibly an unspecified impact through deeply nested for loops (also known as the word_lineno issue)

              CERT VULNERABILITY NOTE CVE-2014-7186 The redirection implementation in parsey in GNU BASH through v 43 allowed remote attackers to cause a denial of service (out-of-bounds array access and application crash) or possibly an unspecified impact through the redir_stack issue

              CERT VULNERABILITY NOTE CVE-2014-6271 CVE-3014-6277 CVE-2014-6278 AND CVE-2014-7169 GNU Bash through v 43 processed trailing strings after function definitions in the values of environment variables which allowed remote attackers to execute arbitrary code via a crafted environment (also known as the ShellShock vulnerability)

              NIOS 701 Release Notes

              copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 13 of 21 400-0579-001 Rev A 1212015

              CERT VULNERABILITY NOTE CVE-2014-3470 Enabling anonymous ECDH cipher suites on TLS clients could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0224 A specially crafted handshake packet could force the use of weak keying material in the SSLTLS clients allowing a man-in-the-middle (MITM) attack to decrypt and modify traffic between a client and a server CERT VULNERABILITY NOTE CVE-2014-0221 Remote attackers could utilize DTLS hello message in an invalid DTLS handshake to cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0198 Enabling SSL_MODE_RELEASE_BUFFERS failed to manage buffer pointer during certain recursive calls that could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0195 Remote attackers could trigger buffer overrun attack through invalid DTLS fragments to an OpenSSL DTLS client or server resulting in a denial of service CERT VULNERABILITY NOTE CVE-2014-0591 A crafted query against an NSEC3-signed zone could cause the named process to terminate RESOLVED ISSUES The following issues were reported in previous NIOS releases and resolved in this release The resolved issues are listed by severity For descriptions of the severity levels refer to Severity Levels on page 16 Fixed in 701

              ID Severity Summary

              NIOS-51535 Major An IPv6 address configured before NIOS 640 was not properly preserved during an upgrade to NIOS 700 which caused an error during product initialization

              Fixed in 700

              ID Severity Summary

              NIOS-50432 Critical Addressed zone journal file size issues that caused DNS service to slow down

              NIOS-50295 Critical After a DIW import there were some missing delegations and records in the Grid data set

              NIOS-50162 NIOS-50124

              Critical Under certain circumstances intermittent DNS service interruptions occurred

              ID Severity Summary

              NIOS-51186 Major DNS failed to respond to some queries due to new limits exposed by CVE-2014-8500

              NIOS-51051 Major DNS service interruptions occurred after changing RPZ records

              NIOS 701 Release Notes

              copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 14 of 21 400-0579-001 Rev A 1212015

              NIOS-50894 Major Updated the Infoblox NIOS Administrator Guide to include information about virtual TFTP root is supported only for file downloads but not for file uploads using TFTP client

              NIOS-50784 Major Addressed the following OpenVPN vulnerability CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet

              NIOS-50532 Major Addressed the following vulnerabilities CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation

              NIOS-50617 NIOS-49810

              Major Grid Manager inappropriately marked IPv6 leases as having invalid MAC addresses

              NIOS-50575 Major NIOS did not show the root domain for Microsoft servers belonging to two Domains in the same Forest

              NIOS-50567 Major DIW failed to handle common CNAME records in different DNS views

              NIOS-50453 Major Added information about HA Grid Master providing NTP service through VIP to the Infoblox NIOS Administrator Guide

              NIOS-50402 Major Under certain circumstances NIOS returned option 43 in the response when users applied a non-global IPv4 option filter to a DHCP range

              NIOS-50250 Major Unable to remove a Grid from the Master Grid

              NIOS-50208 Major On some occasions the inheritance state for inherited extensible attributes was displayed as ldquooverriddenrdquo instead of ldquoinheritedrdquo

              NIOS-50199 Major Unable to modify a DHCP scope that was synchronized from a Microsoft DHCP failover partner

              NIOS-50171 Major Users could not convert a lease to a fixed address without the ldquoNetwork Discoveryrdquo permission which was not required

              NIOS-50137 Major VLAN tagging was not functional properly on the HA interface

              NIOS-50112 Major High CPU usage on Captive Portal caused by the ldquoomshellrdquo process

              NIOS-50081 Major Unable to add the same IPv6 loopback address on other Grid members when the IPv6 address is already configured on the Grid Master

              NIOS-50057 Major DHCP service interruptions occurred after an upgrade due to issues related to disabled Grid members in a MAC address filter

              NIOS-50052 Major Addressed the following SSL 30 vulnerability CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

              NIOS-49962 Major Unable to edit and save Upgrade Schedule

              NIOS-49941 Major In a Multi-Grid configuration the Master Grid experienced high swap usage while processing a lot of data

              NIOS-49935 Major Under certain circumstances exporting visible data from Grid Manager could fail for a zone

              NIOS 701 Release Notes

              copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 15 of 21 400-0579-001 Rev A 1212015

              NIOS-49934 Major API On rare occasions searching with return_methods could result in incorrect PAPI results

              NIOS-49847 Major The appliance returned an error when users tried to disable GSS-TSIG and remove the keys

              NIOS-49826 Major Could not start DNS service on the Grid Secondary for a zone that had an external Primary while moving the LAN2 IP address from one member to the other

              NIOS-49809 Major In a network template users could not save values for an extensible attribute that was a ldquolistrdquo type

              NIOS-49735 Major The status of a Microsoft server was ldquoConnectingrdquo even when synchronization was in progress

              NIOS-49505 Major High disk space usage was observed after enabling ldquoCapture DNS Queriesrdquo and ldquoCapture DNS Responsesrdquo

              NIOS-49473 Major On rare occasions the Grid Master rebooted and went offline

              NIOS-49349 Major The infobloxlog captured bloxTools user password in plain text

              NIOS-49339 Major Grid Manager access was denied due to a missing object in the backup file

              NIOS-49137 Major Advanced DNS Protection An unexpected HA failover occurred due to a general protection fault

              NIOS-48437 Major DNS latency for DNS responses from cache was higher than usual for a duration of a couple seconds

              NIOS-48009 Major A schedule upgrade did not function properly if the HA Grid Master had not replicated the schedule to the passive node before the upgrade started

              NIOS-47994 Major DHCP service failed to start due to invalid DHCP option spaces defined in the DHCP configuration file

              NIOS-50571 Minor Added descriptions about VLAN tag and DSCP support for TE-1400 series appliances to the Infoblox NIOS Administrator Guide

              NIOS-50466 Minor DNS service startup took longer than expected due to journal file fragmentation

              NIOS-50430 Minor Redefined the description for ldquoinfoblox-deny-rpzrdquo in the Infoblox NIOS Administrator Guide

              NIOS-50401 Minor When associating a network with a Microsoft site an error message was displayed in the background instead of inside the editor

              NIOS-50366 Minor Updated the CSV Import Reference to include the file format for ldquoresponsepolicyipaddressrdquo objects

              NIOS-50267 Minor Unable to perform a discovery for a Microsoft managed subnet

              NIOS-49986 Minor Updated IP addresses used in example in the Infoblox NIOS Administrator Guide

              NIOS-49838 Minor Could not transfer support bundle using the transfer_supportbundle command

              NIOS-49816 Minor The Discoverer field value was truncated in the IP MAP viewer under the Discovered Data tab

              NIOS-49787 Minor The appliance logged excessive debugging messages

              NIOS 701 Release Notes

              copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 16 of 21 400-0579-001 Rev A 1212015

              NIOS-48037 Minor Value for the extensible attribute ldquoSiterdquo was not displayed in the Lease Selector when

              users tried to connect to an auto-provisioned member

              NIOS-50399 Enhance Enhanced the ldquoConvertrdquo button to also appear in the IPAM home page

              Severity Levels Severity Description

              Critical Core network services are significantly impacted Major Network services are impacted but there is an available workaround Moderate Some loss of secondary services or configuration abilities Minor Minor functional or UI issue Enhance An enhancement to the product

              KNOWN GENERAL ISSUES

              ID Summary

              NIOS-51323 DNS Traffic Control The appliance may return a timeout error while loading the Traffic Management tab in Grid Manager if you have configured health monitoring for a lot of DTC servers

              NIOS-51287 Cloud Network Automation Modifying resource records through the cloud API will cause extensible attribute values to be removed

              NIOS-51235 In a Multi-Grid configuration converting network connectivity for the Master Grid and its sub Grids to IPv6 only is not supported even though Grid Manager may allow you to do so

              NIOS-51134 Infoblox appliances currently do not support HP passive copper cables

              NIOS-51054 After you upgrade to NIOS 700 Infoblox recommends that you back up the configuration after you change network connectivity to a different mode (IPv4 IPv6 or IPv4 and IPv6 dual mode) Restoring an old backup by performing a forced restore may prevent some Grid members from rejoining the Grid after the restore

              NIOS-50997 In this release the appliance does not automatically create a reverse-mapping zones for 1 for DNS servers that support IPv6

              NIOS-50873 When you enable DNS and DHCP services for IPv6 only DDNS updates may not function properly for certain configurations Infoblox recommends that you do not enable DDNS updates in an IPv6-only Grid

              NIOS-50859 Creating custom IPv6 NS records and pointing a zone to a particular IPv6 name server is not supported in this release

              NIOS-50994 Cloud Network Automation When there is no tenant associated with a network or VM or if a network or VM is created by a cloud adapter but the tenant ID is not specified in the cloud API request the Name or ID column for the tenant or VM is left blank in Grid Manager which implies ldquoNArdquo or not applicable for the specified network or VM

              NIOS 701 Release Notes

              copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 17 of 21 400-0579-001 Rev A 1212015

              NA Reporting When there is too much data being displayed in a graph data can overlap each other and make it difficult for viewing You can expand the graph to view specific data by stretching the graph on display However you will not be able to download the expanded graph in a PDF Workaround Right-click the expanded graph and then select This Frame -gt Print Frame from the drop-down menu to print the graph

              NIOS-49238 Network Insight Under certain circumstances deleting networks may not remove the corresponding IP helper addresses from the device configuration

              NIOS-49123 Network Insight When scheduling a discovery or port control blackout the scheduled time and time zone will always be standard time No time adjustments are made if the selected time zone is currently in daylight savings time and no adjustments are made when the time zone switches to daylight savings time

              NIOS-49107 Network Insight If a recurring port control blackout is scheduled and it includes the current time port control tasks will be delayed during the current blackout period However you may not be warned until the next blackout period If a recurring discovery blackout is scheduled and it includes the current time the Discover Now functionality may not be blocked until the next blackout period

              AUGUSTA2-1606

              Network Insight Some devices such as the Cisco 3750X may report interfaces (that are not actually functional) as available through SNMP which could cause Port Control jobs on these non-functional interfaces to fail

              NIOS-48944 Reporting When there are disconnected data points in the reporting data for reports (such as the DNS Query Rate by Query Type report) that support the stacked area panel type the stacked area that represents the disconnected data in the PDF report may not fill up accordingly and may cause it to look like a line chart when it is actually a stacked area chart Workaround Interpret the information correctly when reading the stacked area charts that contain disconnected data points

              NIOS-48912 Network Insight Is a device is not connected to another host through a network the appliance will not be able to detect the Voice VLAN information

              NIOS-48897 Network Insight Alcatel Omniswitches can operate in two modesmdashWorking mode and Certified mode Alcatel OmniSwitch 6000 devices must run in Working mode to allow Port Control jobs to work on these devices

              NIOS-48704 Reporting When you configure a search for Top Devices Denied an IP Address using Member Network View Network and CIDR as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

              NIOS-48560 Network Insight Before joining the Network Data Consolidator to the Grid use the CLI command reset net-automation database to ensure that previously discovered device information is removed from the database

              NIOS-48399 You cannot restore the existing deleted resource records from the Recycle Bin after you promote a Grid Master Candidate to the Grid Master

              NIOS-48311 On the IB-4010 appliance the maximum resource records allowed in a single signing zone is 800K not 25 of the object limit as in other platforms Exceeding this limit may result in a system restart

              NIOS-48135 bloxTools data prior to NIOS 640 cannot be restored on NIOS 611x Workaround Upgrade to NIOS 64x first to get a backup before upgrading to NIOS 611x

              NIOS 701 Release Notes

              copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 18 of 21 400-0579-001 Rev A 1212015

              NIOS-48030 You may not be able to log in to the bloxTools Workflow environment if you download the snapin-workflow file from the bloxTools Community site

              NIOS-47959 Through the API and RESTful API users can add records and data without entering values for required extensible attributes Users cannot do the same through Grid Manager

              NIOS-46356 An upgrade may fail if you clone reports and searches with duplicate names for the following reports DNS Query Rate by Server DNS Daily Query Rate by Server DNS Daily Peak Hour Query Rate by Server DHCP Device Operating System Trend DHCP Top Device Operating System and Traffic Rate

              NIOS-46290 In some scenarios upgrading from NIOS 67x to NIOS 610x on an Infoblox-4030 appliance may require a manual restart to complete the upgrade

              NIOS-46102 Advanced DNS Protection You may not be able to join an independent appliance to the Grid if the appliance has threat protection service enabled and only the LAN interface configured Workaround Disable threat protection service on the appliance before joining the Grid or configure the MGMT port and enable VPN on MGMT before joining the offline appliance to the Grid

              NIOS-46051 Reporting When you configure a search for Threat Protect Event Count by Severity Trend using Member Category and Rule ID as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

              NIOS-45906 Network Insight On rare occasions when there is incomplete inaccurate or misinterpreted data in discovered spanning tree information the appliance may not be able to determine the correct switch to which an end host is attached In this scenario the appliance may display inaccurate discovered data

              NIOS-45904 Network Insight In Grid Manager the same end host on different VLANs may appear as duplicates that contain the same VLAN information

              NIOS-45872 Content in the bloxHub widget on the Status Dashboard may not be displayed in certain versions of Google Chrome Mozilla FireFox and Microsoft Internet Explorer browsers due to security updates implemented by these browsers Workarounds For Chrome Click the security shield icon next to the URL and select Load unsafe script For FireFox Click the security shield icon next to the URL and select Disable Protection on This Page from the drop-down list For IE Click Show all content in the Only secure content is displayed message bar at the bottom of the page

              NIOS-45598 Network Insight When a seed router is specified for an IP address that has already been assigned as a fixed address the IP will still be discovered even if the fixed address is excluded from discovery

              NIOS-45233 Reporting When you use Microsoft Internet Explorer 10x and disable ldquoCompatibility Viewrdquo you may not be able to view reports in the Reporting tab Workaround In the Internet Explorer 10 browser go to Tools -gt Compatibility View to enable the feature

              NIOS-45220 When you upgrade from NIOS 51r6-12 or earlier releases the Try Snapinstall option may not be available in the bloxTools environment after the upgrade Workaround Stop bloxTools service on the member console connect to the member through the CLI and execute the set bloxtools reset all command Once the reset process is complete restart the bloxTools service to access the Try Snapinstall option

              NIOS 701 Release Notes

              copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 19 of 21 400-0579-001 Rev A 1212015

              VLAN-324 If you have assigned multiple VLANs to the LAN1 or LAN2 interfaces on the appliance you may receive messages about having ldquomultiple interfaces that match the same subnetrdquo during dhcpd process startups or restarts Note that these are not error messages and no actions are required

              NIOS-44055 If you use certain versions of Mozilla FireFox to run Grid Manager the auto-detected time zone feature may not function properly even if you have enabled it in your User Profile

              NIOS-43957 When you upgrade from NIOS 66x or earlier releases the email address in the SOA resource record that was entered in punycode will be converted into IDN (Internationalized Domain Name) after the upgrade Workaround Convert the IDN back to punycode using the IDN converter utility through Grid Manager

              NIOS-43569 You may not be able to view reverse-mapping zones in an internal DNS view Workaround Set the table size to 10 in User Profile log out and then log back in to the system again

              NIOS-41136 Reporting When you use certain versions of Mozilla Firefox and Google Chrome browsers on Windows 7 or Linux you may not be able to properly print reports

              NIOS-39922 On Trinzic 2200 series appliances it may take up to three minutes for the LOM (Light On Management) LED to stop blinking after you have disabled the LOM feature

              NIOS-38870 When you change the member type of an appliance from Infoblox to vNIOS the appliance might display an error message indicating that all network port settings of the vNIOS member must be changed to Automatic Workaround Through the Infoblox API use InfobloxGridMember and the functions lan_port_duplex( ) and lan_port_speed ( ) to change the network port settings for the vNIOS member

              NIOS-38579 Reporting If you have a quick filter that includes a filter criterion with report comment equals to a value that NIOS automatically translates to another value the quick filter may not function properly after an upgrade to NIOS 65 or 66 NIOS automatically translates the following ldquoIPAM Utilizationrdquo to ldquoDDI Utilizationrdquo ldquoDNS Zone Statistics per DNS Viewrdquo to ldquoDNS Statistics per DNS Viewrdquo ldquoDNS Zone Statistics per DNS Zonerdquo to ldquoDNS Statistics per Zonerdquo ldquoDNS Member QPS Trendrdquo to ldquoDNS Query Rate by Serverrdquo and ldquoDNS Queries per Second Trendrdquo to ldquoDNS Query Rate by Query Typerdquo Workaround 1 Edit the original report comment values to match the translated values For example if you have entered ldquoIPAM Utilizationrdquo in the comment field of a report change it to ldquoDDI Utilizationrdquo Workaround 2 Edit the quick filter names to match the original comment values For example if you have entered ldquoQF1rdquo as a quick filter name and ldquoIPAM Utilizationrdquo as the report comment change the quick filter name to ldquoIPAM Utilizationrdquo

              NIOS-37415 Users cannot execute Trinzic Automation Engine (TAE) if they log out of NetMRI during an active NetMRI session

              NIOS-33600 There is an issue with SafeNet HSMs in that configuration changes do not immediately take effect such as when adding a new member to an existing SafeNet HSM Group deleting a client from the HSM or making member changes You can perform a forced restart of services to apply the changes immediately

              NIOS-31864 Modifying a zone from a client increments the zonersquos serial number even if the zone contents did not change This causes unnecessary AXFRs to secondary servers and if the zone is served by a Microsoft Server that is managed in read-write mode it causes extra synchronizations as well

              NIOS 701 Release Notes

              copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 20 of 21 400-0579-001 Rev A 1212015

              NIOS-31501 When a Microsoft server is the primary server for a zone and another Microsoft server is hosting the same zone as a stub zone and the NIOS appliance synchronizes DNS data with only one of these zones it will synchronize the zone as an authoritative or stub zone depending on which Microsoft server it synchronizes with first For more information please refer to KB article 17593

              NIOS-25064 (45488)

              If you configured a member DHCP server to authenticate DHCP clients with a RADIUS authentication server group and RADIUS is disabled (the server group is disabled all RADIUS servers in the group are disabled or the member DHCP server was not assigned an authentication server group) NAC filters with ldquodoes not equalrdquo rules will always match Workaround Do not disable RADIUS

              NIOS-21512 (39917)

              When you stop the DNS service of an independent appliance with temporary DNS and DHCP licenses Grid Manager displays the Restart Services panel regardless of which function you select

              NIOS-21499 (38968)

              An admin cannot display DNS views created by other admins during the same browser session To display the DNS views created by other admins you must log out and log in again

              NIOS-19853 (31668)

              Grid Manager does not display an error when you move a DNS view to a network view that contains a host record that has the same MAC address as a host record in the DNS view that is being moved

              NIOS-19144 (30208)

              Grid Manager does not sort columns correctly in the IPAM and Network list panels when the columns contain UTF-8 data

              NIOS-18163 (27831)

              The appliance allows users with read-only permission to A records to view DNSSEC resource records as well

              NIOS-17636 (26233)

              Syslog messages generated during a TFTP file transfer display the incorrect time zone

              NIOS-17513 (26080)

              Adding updating or deleting reverse zones could fail due to unsupported PTR records in the root zone

              PAPIPASS-39

              When you use Mozilla Firefox 16x 17x or Mozilla Firefox Beta 180b3 browser the hidden password in the Add Administrator Wizard of Grid Manager may disappear when you click the Password field after you have confirmed the password This is a known issue when you use Firefox browsers

              MME-154 When a NIOS user deletes a Microsoft AD domainrsquos primary zones and subzones NIOS should display a more specific message warning users about the consequences of the operation instead of the general warning message it currently displays

              MME-129 When a Microsoft admin creates a delegation on the Microsoft server and the delegation is synchronized to the NIOS appliance the glue A record of the delegation name server is synchronized to the appliance as a manually created record If on the NIOS appliance an admin changes the IP address on the NS record of the delegation name server two A glue records are generated one with the original address one with the new address NIOS retains the original glue A record because itrsquos marked as a manually created record and it can only be changed or deleted either manually on Grid Manager or through the API When synchronization occurs the Microsoft server correctly updates the existing glue A record and does not retain the original Note that NIOS retains the original A record only after the initial update If you update the A record again NIOS just updates the existing record without retaining the original

              MME-23 NIOS displays an ldquoInternal Errorrdquo message when you try to apply a quick filter for a range that equals 1 when you display a range in the IPv4 Microsoft Superscopes tab

              MME-6 If you add a hostname to the Target field of an SRV record on Grid Manager when the member synchronizes the SRV record to a Microsoft server it adds a new SRV record with the hostname instead of modifying the existing record

              NIOS 701 Release Notes

              copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 21 of 21 400-0579-001 Rev A 1212015

              MSSS-11 (45296)

              When you run a discovery on a network served by Microsoft servers and Grid Manager discovers a MAC address that does not match any of the fixed addresses associated with an IP address it reports a conflict and lists the associated fixed address objects in the Related Objects table You cannot select which fixed address to resolve in the Related Objects table You can only resolve the conflict for the first address

              VNIOS-36 (41215)

              If a virtual NIOS member does not start up due to a license violation Grid Manager displays the status of the vNIOS member as ldquoonlinerunningrdquo even though the member is not online

              • INTRODUCTION
                • Supported Platforms
                  • NEW FEATURES
                    • NIOS 700
                      • CHANGES TO DEFAULT BEHAVIOR
                        • NIOS 700
                        • NIOS 6x Releases
                          • CHANGES TO Infoblox API and RESTful API
                            • RESTful API Deprecation and Backward Compatibility Policy
                            • NIOS 70x
                            • NIOS 6x Releases
                              • UPGRADE GUIDELINES
                                • Upgrading to NIOS 70x
                                  • BEFORE YOU INSTALL
                                  • ACCESSING GRID MANAGER
                                  • ADDRESSED VULNERABILITIES
                                  • RESOLVED ISSUES
                                    • Fixed in 701
                                    • Fixed in 700
                                      • KNOWN GENERAL ISSUES

                NIOS 701 Release Notes

                copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 8 of 21 400-0579-001 Rev A 1212015

                RESTful API Deprecation and Backward Compatibility Policy This policy covers the interfaces exposed by the Infoblox RESTful API and the protocol used to communicate with it

                Unless explicitly stated in the release notes previously available RESTful API versions are intended to remain accessible and operative with later versions

                The planned deprecation of a given version of the RESTful API will normally be announced in the release notes at least one year in advance Upon deprecation the announced RESTful API version and all prior versions will no longer be supported in subsequent releases For example if the current RESTful API release is v34 and the release notes contain an announcement of the v15 deprecation v14 and v15 API requests would continue to work with later releases for one year from the announcement date After that some or all requests for these deprecated versions may not work with versions later than v15 API requests adherent to versions later than v15 (v20 for example) would continue to work with subsequent releases Infoblox seeks to avoid any deprecation that has not been announced in advance however product modifications and enhancements may affect specific API requests without a prior announcement Infoblox does not warrant that all API requests will be unaffected by future releases This policy applies to both major and minor versions of the RESTful API Infoblox reserves the right to change this policy NIOS 70x

                bull When executing a RESTful API request from version 20 and later the XML data format has been updated to accommodate tag names (used primarily in extensible attributes) that contain spaces andor invalid XML characters

                NIOS 6x Releases

                bull The RESTful API (WAPI) sample code advises using curl -k3 to access the RESTful API through SSLv3 SSLv3 is no longer supported and the ndashk3 option in curl is no longer supported To correctly use curl to access the RESTful API specify curl -k1 to force the use of TLS

                bull The following changes for keytabs have been made in the Infoblox API

                remove_datakeytab has been removed

                import_datakeytab has been removed

                import_dataupload_keytab has been added

                The API also supports multiple TSIG keys To use a keytab you must upload it and manually assign it to individual members or to DHCP you cannot complete this task in one operation If you have only one keytab you can still use the old gss_tsig members However Infoblox recommends that you switch to the new gss_tsig_keysipv6_gss_tsig_keys members

                bull The following objects have been deprecated in the Infoblox API

                InfobloxGridMSServerDNS (new object InfobloxGridMSServerServerDNS)

                status_last_updated member in InfobloxGridMSServerDNS (new object status_last_updated_ts member in epoc format)

                Though the deprecated objects will continue to function for backward compatibility purposes Infoblox recommends that you use the new objects in your new code

                bull The InfobloxGridAdminUser object password method and the InfobloxGrid object secret method have been modified to adhere to Infoblox security policies

                NIOS 701 Release Notes

                copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 9 of 21 400-0579-001 Rev A 1212015

                bull API and RESTful API After upgrading to NIOS 67x all international domain names (IDNs) in punycode are converted to Unicode (in the respective API way of encoding Unicode strings) You can use the dns_[hellip] fields in relevant objects to retrieve read-only IDNs in punycode For more information about IDNs refer to the Infoblox NIOS Administrator Guide For information about API and RESTful API refer to the Infoblox API Documentation and Infoblox RESTful API Documentation

                UPGRADE GUIDELINES Upgrading to NIOS 70x NOTES

                bull You cannot upgrade NIOS 6124 to NIOS 70x You will however be able to upgrade NIOS 6124 and later to NIOS 71x releases when they become available

                bull You cannot upgrade directly from NIOS 5x to NIOS 70x However you can first upgrade to NIOS 66x or later and then to NIOS 70x

                You cannot upgrade to NIOS 70x on the following appliances IB-250-A IB-550-A IB-1050-A IB-1550-A IB-1552-A IB-1852-A IB-2000 IB-2000-A IB-VM-250 IB-VM-550 IB-VM-1050 IB-VM-1550 IB-VM-1850 IB-VM-2000 and Trinzic Reporting TR-2000 series appliances For information about supported platforms see Supported Platforms on page 1 Note the following for IPv6 Grid support

                bull If your Grid Master is configured with an IPv6 VIP all Grid Master Candidates must also include an IPv6 VIP For an HA pair both nodes of the HA pair must have IPv6 addresses for the Grid Master and the Grid Master Candidate

                bull After you upgrade to NIOS 70x Infoblox recommends that you back up the configuration after you change network connectivity to a different mode (IPv4 IPv6 or IPv4 and IPv6 dual mode) Restoring an old backup by performing a forced restore may prevent some Grid members from rejoining the Grid after the restore

                bull IPv6-only configuration does not support the following HSM LCD NAT groups OSPF and BGP

                When you schedule a full upgrade from a previous release to NIOS 70x the following DNSSEC limitations are applicable

                bull You cannot configure new settings that are added to the authoritative zone object while the upgrade is still in progress This restriction is not applicable to future upgrades

                bull When you upgrade you can sign or unsign an authoritative zone only if the Grid Master Candidate and the associated serving members are upgraded This restriction is not applicable to future upgrades

                bull An authoritative zone can have its KSK rollover only if the Grid Master Candidate and all the serving members are upgraded This restriction is not applicable to future upgrades

                bull An authoritative zone can have its ZSK rollover by the daemon only if the Grid Master Candidate and all the serving members are upgraded This restriction is not applicable to future upgrades

                bull You cannot delete keys while the upgrade is still in progress bull You cannot update DNSSEC related parameters at the member level while the upgrade is still in

                progress Example rollover mechanism NSEC3 salt length and iterations and enable or disable automatic KSK rollover

                NIOS 701 Release Notes

                copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 10 of 21 400-0579-001 Rev A 1212015

                For Cloud Network Automation bull After upgrading to NIOS 70x you must manually select the Delegated To Cloud Usage

                and Owned By columns in the Data Management tab of Grid Manager to display relevant information This is applicable only if you have installed the Cloud Network Automation license on the Grid Master

                BEFORE YOU INSTALL To ensure that new features and enhancements operate properly and smoothly Infoblox recommends that you evaluate the capacity on your Grid and review the upgrade guidelines before you upgrade from a previous NIOS release Infoblox recommends that administrators planning to perform an upgrade from a previous release create and archive a backup of the Infoblox appliance configuration and data before upgrading You can run an upgrade test before performing the actual upgrade Infoblox recommends that you run the upgrade test so you can resolve any potential data migration issues before the upgrade Following is a list of upgrade and revert paths You can also schedule a full upgrade from these releases 700 6122 and earlier 612x releases 6117 and earlier 611x releases 610201 and 610200 61010 and earlier 610x releases 69201-LD and 69200-LD 690 6813 and earlier 68x releases 678 and earlier 67x releases 6613 and earlier 66x releases Technical Support Infoblox technical support contact information

                Telephone 1-888-463-6259 (toll-free US and Canada) +1-408-625-4200 ext 1

                E-mail supportinfobloxcom

                Web httpssupportinfobloxcom

                GUI Requirements Grid Manager supports the following operating systems and browsers You must install and enable Javascript for Grid Manager to function properly Grid Manager supports only SSL version 3 and TLS version 1 connections Infoblox recommends that you use a computer that has a 2 GHz CPU and at least 1 GB of RAM

                NIOS 701 Release Notes

                copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 11 of 21 400-0579-001 Rev A 1212015

                Infoblox supports the following browsers for Grid Manager

                OS Browser Microsoft Windows 80 and 81reg Microsoft Internet Explorerreg 11x 10x

                Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                Microsoft Windows 7reg Microsoft Internet Explorerreg 11x 10x 9x and 8x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                Microsoft Windows XPreg (SP2+) Microsoft Internet Explorer 7x and 8x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                Red Hatreg Enterprise Linuxreg 7x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                Red Hatreg Enterprise Linuxreg 6x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                Red Hatreg Enterprise Linux 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                Applereg Mac OS X 109x Safari 7x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                Applereg Mac OS X 108x Safari 6x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                Applereg Mac OS X 107x Safari 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                Applereg Mac OS X 106x Safari 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                NOTE Grid Manager fully supports Microsoft Internet Explorerreg 11x and 10x when you enable compatibility view in the browser Features in the Reporting tab may not function properly if you disable compatibility view In the browser go to Tools -gt Compatibility View to enable the feature When viewing Grid Manager set the screen resolution of your monitor as follows

                Minimum resolution 1280 x 768 Recommended resolution 1280 x 1024 or better

                Documentation You can download the Infoblox NIOS Administrator Guide from the appliance From Grid Manager expand the Help panel and then click Documentation -gt Admin Guide Training Training information is available at httpinterviewcentralcomeventsuploadsinfobloxloginhtml

                NIOS 701 Release Notes

                copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 12 of 21 400-0579-001 Rev A 1212015

                ACCESSING GRID MANAGER Before you log in to Grid Manager ensure that you have installed your NIOS appliance as described in the installation guide or user guide that shipped with your product and configured it accordingly To log in to Grid Manager

                1 Open an Internet browser window and enter httpsltIPv4 address or hostname of your NIOS appliancegt or https[IPv6 address] of your NIOS appliance The Grid Manager login page appears

                2 Enter your user name and password and then click Login or press Enter The default user name is admin and password is infoblox

                3 Read the Infoblox End-User License Agreement and click I Accept to proceed Grid Manager displays the Dashboard your home page in Grid Manager

                ADDRESSED VULNERABILITIES This section lists security vulnerabilities that were addressed in the past 12 months For vulnerabilities that are not listed in this section refer to Infoblox KB 2899 For additional information about these vulnerabilities including their severities please refer to the National Vulnerability Database (NVD) at httpnvdnistgov The Infoblox Support website at httpssupportinfobloxcom also provides more information including vulnerabilities that do not affect Infoblox appliances CERT VULNERABILITY NOTE CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation CERT VULNERABILITY NOTE CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet CERT VULNERABILITY NOTE CVE-2014-3566 SSL3 is vulnerable to man-in-the-middle-attacks SSL3 is disabled in NIOS and connections must use TLSv1 (which is already used by all supported browsers)

                CERT VULNERABILITY NOTE CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

                CERT VULNERABILITY NOTE CVE-2014-7187 Off-by-one error in the read_token_word function in parsey in GNU BASH through v 43 allowed remote attackers to cause a denial of service (out-of-bounds array access and application crash) or possibly an unspecified impact through deeply nested for loops (also known as the word_lineno issue)

                CERT VULNERABILITY NOTE CVE-2014-7186 The redirection implementation in parsey in GNU BASH through v 43 allowed remote attackers to cause a denial of service (out-of-bounds array access and application crash) or possibly an unspecified impact through the redir_stack issue

                CERT VULNERABILITY NOTE CVE-2014-6271 CVE-3014-6277 CVE-2014-6278 AND CVE-2014-7169 GNU Bash through v 43 processed trailing strings after function definitions in the values of environment variables which allowed remote attackers to execute arbitrary code via a crafted environment (also known as the ShellShock vulnerability)

                NIOS 701 Release Notes

                copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 13 of 21 400-0579-001 Rev A 1212015

                CERT VULNERABILITY NOTE CVE-2014-3470 Enabling anonymous ECDH cipher suites on TLS clients could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0224 A specially crafted handshake packet could force the use of weak keying material in the SSLTLS clients allowing a man-in-the-middle (MITM) attack to decrypt and modify traffic between a client and a server CERT VULNERABILITY NOTE CVE-2014-0221 Remote attackers could utilize DTLS hello message in an invalid DTLS handshake to cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0198 Enabling SSL_MODE_RELEASE_BUFFERS failed to manage buffer pointer during certain recursive calls that could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0195 Remote attackers could trigger buffer overrun attack through invalid DTLS fragments to an OpenSSL DTLS client or server resulting in a denial of service CERT VULNERABILITY NOTE CVE-2014-0591 A crafted query against an NSEC3-signed zone could cause the named process to terminate RESOLVED ISSUES The following issues were reported in previous NIOS releases and resolved in this release The resolved issues are listed by severity For descriptions of the severity levels refer to Severity Levels on page 16 Fixed in 701

                ID Severity Summary

                NIOS-51535 Major An IPv6 address configured before NIOS 640 was not properly preserved during an upgrade to NIOS 700 which caused an error during product initialization

                Fixed in 700

                ID Severity Summary

                NIOS-50432 Critical Addressed zone journal file size issues that caused DNS service to slow down

                NIOS-50295 Critical After a DIW import there were some missing delegations and records in the Grid data set

                NIOS-50162 NIOS-50124

                Critical Under certain circumstances intermittent DNS service interruptions occurred

                ID Severity Summary

                NIOS-51186 Major DNS failed to respond to some queries due to new limits exposed by CVE-2014-8500

                NIOS-51051 Major DNS service interruptions occurred after changing RPZ records

                NIOS 701 Release Notes

                copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 14 of 21 400-0579-001 Rev A 1212015

                NIOS-50894 Major Updated the Infoblox NIOS Administrator Guide to include information about virtual TFTP root is supported only for file downloads but not for file uploads using TFTP client

                NIOS-50784 Major Addressed the following OpenVPN vulnerability CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet

                NIOS-50532 Major Addressed the following vulnerabilities CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation

                NIOS-50617 NIOS-49810

                Major Grid Manager inappropriately marked IPv6 leases as having invalid MAC addresses

                NIOS-50575 Major NIOS did not show the root domain for Microsoft servers belonging to two Domains in the same Forest

                NIOS-50567 Major DIW failed to handle common CNAME records in different DNS views

                NIOS-50453 Major Added information about HA Grid Master providing NTP service through VIP to the Infoblox NIOS Administrator Guide

                NIOS-50402 Major Under certain circumstances NIOS returned option 43 in the response when users applied a non-global IPv4 option filter to a DHCP range

                NIOS-50250 Major Unable to remove a Grid from the Master Grid

                NIOS-50208 Major On some occasions the inheritance state for inherited extensible attributes was displayed as ldquooverriddenrdquo instead of ldquoinheritedrdquo

                NIOS-50199 Major Unable to modify a DHCP scope that was synchronized from a Microsoft DHCP failover partner

                NIOS-50171 Major Users could not convert a lease to a fixed address without the ldquoNetwork Discoveryrdquo permission which was not required

                NIOS-50137 Major VLAN tagging was not functional properly on the HA interface

                NIOS-50112 Major High CPU usage on Captive Portal caused by the ldquoomshellrdquo process

                NIOS-50081 Major Unable to add the same IPv6 loopback address on other Grid members when the IPv6 address is already configured on the Grid Master

                NIOS-50057 Major DHCP service interruptions occurred after an upgrade due to issues related to disabled Grid members in a MAC address filter

                NIOS-50052 Major Addressed the following SSL 30 vulnerability CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

                NIOS-49962 Major Unable to edit and save Upgrade Schedule

                NIOS-49941 Major In a Multi-Grid configuration the Master Grid experienced high swap usage while processing a lot of data

                NIOS-49935 Major Under certain circumstances exporting visible data from Grid Manager could fail for a zone

                NIOS 701 Release Notes

                copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 15 of 21 400-0579-001 Rev A 1212015

                NIOS-49934 Major API On rare occasions searching with return_methods could result in incorrect PAPI results

                NIOS-49847 Major The appliance returned an error when users tried to disable GSS-TSIG and remove the keys

                NIOS-49826 Major Could not start DNS service on the Grid Secondary for a zone that had an external Primary while moving the LAN2 IP address from one member to the other

                NIOS-49809 Major In a network template users could not save values for an extensible attribute that was a ldquolistrdquo type

                NIOS-49735 Major The status of a Microsoft server was ldquoConnectingrdquo even when synchronization was in progress

                NIOS-49505 Major High disk space usage was observed after enabling ldquoCapture DNS Queriesrdquo and ldquoCapture DNS Responsesrdquo

                NIOS-49473 Major On rare occasions the Grid Master rebooted and went offline

                NIOS-49349 Major The infobloxlog captured bloxTools user password in plain text

                NIOS-49339 Major Grid Manager access was denied due to a missing object in the backup file

                NIOS-49137 Major Advanced DNS Protection An unexpected HA failover occurred due to a general protection fault

                NIOS-48437 Major DNS latency for DNS responses from cache was higher than usual for a duration of a couple seconds

                NIOS-48009 Major A schedule upgrade did not function properly if the HA Grid Master had not replicated the schedule to the passive node before the upgrade started

                NIOS-47994 Major DHCP service failed to start due to invalid DHCP option spaces defined in the DHCP configuration file

                NIOS-50571 Minor Added descriptions about VLAN tag and DSCP support for TE-1400 series appliances to the Infoblox NIOS Administrator Guide

                NIOS-50466 Minor DNS service startup took longer than expected due to journal file fragmentation

                NIOS-50430 Minor Redefined the description for ldquoinfoblox-deny-rpzrdquo in the Infoblox NIOS Administrator Guide

                NIOS-50401 Minor When associating a network with a Microsoft site an error message was displayed in the background instead of inside the editor

                NIOS-50366 Minor Updated the CSV Import Reference to include the file format for ldquoresponsepolicyipaddressrdquo objects

                NIOS-50267 Minor Unable to perform a discovery for a Microsoft managed subnet

                NIOS-49986 Minor Updated IP addresses used in example in the Infoblox NIOS Administrator Guide

                NIOS-49838 Minor Could not transfer support bundle using the transfer_supportbundle command

                NIOS-49816 Minor The Discoverer field value was truncated in the IP MAP viewer under the Discovered Data tab

                NIOS-49787 Minor The appliance logged excessive debugging messages

                NIOS 701 Release Notes

                copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 16 of 21 400-0579-001 Rev A 1212015

                NIOS-48037 Minor Value for the extensible attribute ldquoSiterdquo was not displayed in the Lease Selector when

                users tried to connect to an auto-provisioned member

                NIOS-50399 Enhance Enhanced the ldquoConvertrdquo button to also appear in the IPAM home page

                Severity Levels Severity Description

                Critical Core network services are significantly impacted Major Network services are impacted but there is an available workaround Moderate Some loss of secondary services or configuration abilities Minor Minor functional or UI issue Enhance An enhancement to the product

                KNOWN GENERAL ISSUES

                ID Summary

                NIOS-51323 DNS Traffic Control The appliance may return a timeout error while loading the Traffic Management tab in Grid Manager if you have configured health monitoring for a lot of DTC servers

                NIOS-51287 Cloud Network Automation Modifying resource records through the cloud API will cause extensible attribute values to be removed

                NIOS-51235 In a Multi-Grid configuration converting network connectivity for the Master Grid and its sub Grids to IPv6 only is not supported even though Grid Manager may allow you to do so

                NIOS-51134 Infoblox appliances currently do not support HP passive copper cables

                NIOS-51054 After you upgrade to NIOS 700 Infoblox recommends that you back up the configuration after you change network connectivity to a different mode (IPv4 IPv6 or IPv4 and IPv6 dual mode) Restoring an old backup by performing a forced restore may prevent some Grid members from rejoining the Grid after the restore

                NIOS-50997 In this release the appliance does not automatically create a reverse-mapping zones for 1 for DNS servers that support IPv6

                NIOS-50873 When you enable DNS and DHCP services for IPv6 only DDNS updates may not function properly for certain configurations Infoblox recommends that you do not enable DDNS updates in an IPv6-only Grid

                NIOS-50859 Creating custom IPv6 NS records and pointing a zone to a particular IPv6 name server is not supported in this release

                NIOS-50994 Cloud Network Automation When there is no tenant associated with a network or VM or if a network or VM is created by a cloud adapter but the tenant ID is not specified in the cloud API request the Name or ID column for the tenant or VM is left blank in Grid Manager which implies ldquoNArdquo or not applicable for the specified network or VM

                NIOS 701 Release Notes

                copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 17 of 21 400-0579-001 Rev A 1212015

                NA Reporting When there is too much data being displayed in a graph data can overlap each other and make it difficult for viewing You can expand the graph to view specific data by stretching the graph on display However you will not be able to download the expanded graph in a PDF Workaround Right-click the expanded graph and then select This Frame -gt Print Frame from the drop-down menu to print the graph

                NIOS-49238 Network Insight Under certain circumstances deleting networks may not remove the corresponding IP helper addresses from the device configuration

                NIOS-49123 Network Insight When scheduling a discovery or port control blackout the scheduled time and time zone will always be standard time No time adjustments are made if the selected time zone is currently in daylight savings time and no adjustments are made when the time zone switches to daylight savings time

                NIOS-49107 Network Insight If a recurring port control blackout is scheduled and it includes the current time port control tasks will be delayed during the current blackout period However you may not be warned until the next blackout period If a recurring discovery blackout is scheduled and it includes the current time the Discover Now functionality may not be blocked until the next blackout period

                AUGUSTA2-1606

                Network Insight Some devices such as the Cisco 3750X may report interfaces (that are not actually functional) as available through SNMP which could cause Port Control jobs on these non-functional interfaces to fail

                NIOS-48944 Reporting When there are disconnected data points in the reporting data for reports (such as the DNS Query Rate by Query Type report) that support the stacked area panel type the stacked area that represents the disconnected data in the PDF report may not fill up accordingly and may cause it to look like a line chart when it is actually a stacked area chart Workaround Interpret the information correctly when reading the stacked area charts that contain disconnected data points

                NIOS-48912 Network Insight Is a device is not connected to another host through a network the appliance will not be able to detect the Voice VLAN information

                NIOS-48897 Network Insight Alcatel Omniswitches can operate in two modesmdashWorking mode and Certified mode Alcatel OmniSwitch 6000 devices must run in Working mode to allow Port Control jobs to work on these devices

                NIOS-48704 Reporting When you configure a search for Top Devices Denied an IP Address using Member Network View Network and CIDR as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

                NIOS-48560 Network Insight Before joining the Network Data Consolidator to the Grid use the CLI command reset net-automation database to ensure that previously discovered device information is removed from the database

                NIOS-48399 You cannot restore the existing deleted resource records from the Recycle Bin after you promote a Grid Master Candidate to the Grid Master

                NIOS-48311 On the IB-4010 appliance the maximum resource records allowed in a single signing zone is 800K not 25 of the object limit as in other platforms Exceeding this limit may result in a system restart

                NIOS-48135 bloxTools data prior to NIOS 640 cannot be restored on NIOS 611x Workaround Upgrade to NIOS 64x first to get a backup before upgrading to NIOS 611x

                NIOS 701 Release Notes

                copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 18 of 21 400-0579-001 Rev A 1212015

                NIOS-48030 You may not be able to log in to the bloxTools Workflow environment if you download the snapin-workflow file from the bloxTools Community site

                NIOS-47959 Through the API and RESTful API users can add records and data without entering values for required extensible attributes Users cannot do the same through Grid Manager

                NIOS-46356 An upgrade may fail if you clone reports and searches with duplicate names for the following reports DNS Query Rate by Server DNS Daily Query Rate by Server DNS Daily Peak Hour Query Rate by Server DHCP Device Operating System Trend DHCP Top Device Operating System and Traffic Rate

                NIOS-46290 In some scenarios upgrading from NIOS 67x to NIOS 610x on an Infoblox-4030 appliance may require a manual restart to complete the upgrade

                NIOS-46102 Advanced DNS Protection You may not be able to join an independent appliance to the Grid if the appliance has threat protection service enabled and only the LAN interface configured Workaround Disable threat protection service on the appliance before joining the Grid or configure the MGMT port and enable VPN on MGMT before joining the offline appliance to the Grid

                NIOS-46051 Reporting When you configure a search for Threat Protect Event Count by Severity Trend using Member Category and Rule ID as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

                NIOS-45906 Network Insight On rare occasions when there is incomplete inaccurate or misinterpreted data in discovered spanning tree information the appliance may not be able to determine the correct switch to which an end host is attached In this scenario the appliance may display inaccurate discovered data

                NIOS-45904 Network Insight In Grid Manager the same end host on different VLANs may appear as duplicates that contain the same VLAN information

                NIOS-45872 Content in the bloxHub widget on the Status Dashboard may not be displayed in certain versions of Google Chrome Mozilla FireFox and Microsoft Internet Explorer browsers due to security updates implemented by these browsers Workarounds For Chrome Click the security shield icon next to the URL and select Load unsafe script For FireFox Click the security shield icon next to the URL and select Disable Protection on This Page from the drop-down list For IE Click Show all content in the Only secure content is displayed message bar at the bottom of the page

                NIOS-45598 Network Insight When a seed router is specified for an IP address that has already been assigned as a fixed address the IP will still be discovered even if the fixed address is excluded from discovery

                NIOS-45233 Reporting When you use Microsoft Internet Explorer 10x and disable ldquoCompatibility Viewrdquo you may not be able to view reports in the Reporting tab Workaround In the Internet Explorer 10 browser go to Tools -gt Compatibility View to enable the feature

                NIOS-45220 When you upgrade from NIOS 51r6-12 or earlier releases the Try Snapinstall option may not be available in the bloxTools environment after the upgrade Workaround Stop bloxTools service on the member console connect to the member through the CLI and execute the set bloxtools reset all command Once the reset process is complete restart the bloxTools service to access the Try Snapinstall option

                NIOS 701 Release Notes

                copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 19 of 21 400-0579-001 Rev A 1212015

                VLAN-324 If you have assigned multiple VLANs to the LAN1 or LAN2 interfaces on the appliance you may receive messages about having ldquomultiple interfaces that match the same subnetrdquo during dhcpd process startups or restarts Note that these are not error messages and no actions are required

                NIOS-44055 If you use certain versions of Mozilla FireFox to run Grid Manager the auto-detected time zone feature may not function properly even if you have enabled it in your User Profile

                NIOS-43957 When you upgrade from NIOS 66x or earlier releases the email address in the SOA resource record that was entered in punycode will be converted into IDN (Internationalized Domain Name) after the upgrade Workaround Convert the IDN back to punycode using the IDN converter utility through Grid Manager

                NIOS-43569 You may not be able to view reverse-mapping zones in an internal DNS view Workaround Set the table size to 10 in User Profile log out and then log back in to the system again

                NIOS-41136 Reporting When you use certain versions of Mozilla Firefox and Google Chrome browsers on Windows 7 or Linux you may not be able to properly print reports

                NIOS-39922 On Trinzic 2200 series appliances it may take up to three minutes for the LOM (Light On Management) LED to stop blinking after you have disabled the LOM feature

                NIOS-38870 When you change the member type of an appliance from Infoblox to vNIOS the appliance might display an error message indicating that all network port settings of the vNIOS member must be changed to Automatic Workaround Through the Infoblox API use InfobloxGridMember and the functions lan_port_duplex( ) and lan_port_speed ( ) to change the network port settings for the vNIOS member

                NIOS-38579 Reporting If you have a quick filter that includes a filter criterion with report comment equals to a value that NIOS automatically translates to another value the quick filter may not function properly after an upgrade to NIOS 65 or 66 NIOS automatically translates the following ldquoIPAM Utilizationrdquo to ldquoDDI Utilizationrdquo ldquoDNS Zone Statistics per DNS Viewrdquo to ldquoDNS Statistics per DNS Viewrdquo ldquoDNS Zone Statistics per DNS Zonerdquo to ldquoDNS Statistics per Zonerdquo ldquoDNS Member QPS Trendrdquo to ldquoDNS Query Rate by Serverrdquo and ldquoDNS Queries per Second Trendrdquo to ldquoDNS Query Rate by Query Typerdquo Workaround 1 Edit the original report comment values to match the translated values For example if you have entered ldquoIPAM Utilizationrdquo in the comment field of a report change it to ldquoDDI Utilizationrdquo Workaround 2 Edit the quick filter names to match the original comment values For example if you have entered ldquoQF1rdquo as a quick filter name and ldquoIPAM Utilizationrdquo as the report comment change the quick filter name to ldquoIPAM Utilizationrdquo

                NIOS-37415 Users cannot execute Trinzic Automation Engine (TAE) if they log out of NetMRI during an active NetMRI session

                NIOS-33600 There is an issue with SafeNet HSMs in that configuration changes do not immediately take effect such as when adding a new member to an existing SafeNet HSM Group deleting a client from the HSM or making member changes You can perform a forced restart of services to apply the changes immediately

                NIOS-31864 Modifying a zone from a client increments the zonersquos serial number even if the zone contents did not change This causes unnecessary AXFRs to secondary servers and if the zone is served by a Microsoft Server that is managed in read-write mode it causes extra synchronizations as well

                NIOS 701 Release Notes

                copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 20 of 21 400-0579-001 Rev A 1212015

                NIOS-31501 When a Microsoft server is the primary server for a zone and another Microsoft server is hosting the same zone as a stub zone and the NIOS appliance synchronizes DNS data with only one of these zones it will synchronize the zone as an authoritative or stub zone depending on which Microsoft server it synchronizes with first For more information please refer to KB article 17593

                NIOS-25064 (45488)

                If you configured a member DHCP server to authenticate DHCP clients with a RADIUS authentication server group and RADIUS is disabled (the server group is disabled all RADIUS servers in the group are disabled or the member DHCP server was not assigned an authentication server group) NAC filters with ldquodoes not equalrdquo rules will always match Workaround Do not disable RADIUS

                NIOS-21512 (39917)

                When you stop the DNS service of an independent appliance with temporary DNS and DHCP licenses Grid Manager displays the Restart Services panel regardless of which function you select

                NIOS-21499 (38968)

                An admin cannot display DNS views created by other admins during the same browser session To display the DNS views created by other admins you must log out and log in again

                NIOS-19853 (31668)

                Grid Manager does not display an error when you move a DNS view to a network view that contains a host record that has the same MAC address as a host record in the DNS view that is being moved

                NIOS-19144 (30208)

                Grid Manager does not sort columns correctly in the IPAM and Network list panels when the columns contain UTF-8 data

                NIOS-18163 (27831)

                The appliance allows users with read-only permission to A records to view DNSSEC resource records as well

                NIOS-17636 (26233)

                Syslog messages generated during a TFTP file transfer display the incorrect time zone

                NIOS-17513 (26080)

                Adding updating or deleting reverse zones could fail due to unsupported PTR records in the root zone

                PAPIPASS-39

                When you use Mozilla Firefox 16x 17x or Mozilla Firefox Beta 180b3 browser the hidden password in the Add Administrator Wizard of Grid Manager may disappear when you click the Password field after you have confirmed the password This is a known issue when you use Firefox browsers

                MME-154 When a NIOS user deletes a Microsoft AD domainrsquos primary zones and subzones NIOS should display a more specific message warning users about the consequences of the operation instead of the general warning message it currently displays

                MME-129 When a Microsoft admin creates a delegation on the Microsoft server and the delegation is synchronized to the NIOS appliance the glue A record of the delegation name server is synchronized to the appliance as a manually created record If on the NIOS appliance an admin changes the IP address on the NS record of the delegation name server two A glue records are generated one with the original address one with the new address NIOS retains the original glue A record because itrsquos marked as a manually created record and it can only be changed or deleted either manually on Grid Manager or through the API When synchronization occurs the Microsoft server correctly updates the existing glue A record and does not retain the original Note that NIOS retains the original A record only after the initial update If you update the A record again NIOS just updates the existing record without retaining the original

                MME-23 NIOS displays an ldquoInternal Errorrdquo message when you try to apply a quick filter for a range that equals 1 when you display a range in the IPv4 Microsoft Superscopes tab

                MME-6 If you add a hostname to the Target field of an SRV record on Grid Manager when the member synchronizes the SRV record to a Microsoft server it adds a new SRV record with the hostname instead of modifying the existing record

                NIOS 701 Release Notes

                copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 21 of 21 400-0579-001 Rev A 1212015

                MSSS-11 (45296)

                When you run a discovery on a network served by Microsoft servers and Grid Manager discovers a MAC address that does not match any of the fixed addresses associated with an IP address it reports a conflict and lists the associated fixed address objects in the Related Objects table You cannot select which fixed address to resolve in the Related Objects table You can only resolve the conflict for the first address

                VNIOS-36 (41215)

                If a virtual NIOS member does not start up due to a license violation Grid Manager displays the status of the vNIOS member as ldquoonlinerunningrdquo even though the member is not online

                • INTRODUCTION
                  • Supported Platforms
                    • NEW FEATURES
                      • NIOS 700
                        • CHANGES TO DEFAULT BEHAVIOR
                          • NIOS 700
                          • NIOS 6x Releases
                            • CHANGES TO Infoblox API and RESTful API
                              • RESTful API Deprecation and Backward Compatibility Policy
                              • NIOS 70x
                              • NIOS 6x Releases
                                • UPGRADE GUIDELINES
                                  • Upgrading to NIOS 70x
                                    • BEFORE YOU INSTALL
                                    • ACCESSING GRID MANAGER
                                    • ADDRESSED VULNERABILITIES
                                    • RESOLVED ISSUES
                                      • Fixed in 701
                                      • Fixed in 700
                                        • KNOWN GENERAL ISSUES

                  NIOS 701 Release Notes

                  copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 9 of 21 400-0579-001 Rev A 1212015

                  bull API and RESTful API After upgrading to NIOS 67x all international domain names (IDNs) in punycode are converted to Unicode (in the respective API way of encoding Unicode strings) You can use the dns_[hellip] fields in relevant objects to retrieve read-only IDNs in punycode For more information about IDNs refer to the Infoblox NIOS Administrator Guide For information about API and RESTful API refer to the Infoblox API Documentation and Infoblox RESTful API Documentation

                  UPGRADE GUIDELINES Upgrading to NIOS 70x NOTES

                  bull You cannot upgrade NIOS 6124 to NIOS 70x You will however be able to upgrade NIOS 6124 and later to NIOS 71x releases when they become available

                  bull You cannot upgrade directly from NIOS 5x to NIOS 70x However you can first upgrade to NIOS 66x or later and then to NIOS 70x

                  You cannot upgrade to NIOS 70x on the following appliances IB-250-A IB-550-A IB-1050-A IB-1550-A IB-1552-A IB-1852-A IB-2000 IB-2000-A IB-VM-250 IB-VM-550 IB-VM-1050 IB-VM-1550 IB-VM-1850 IB-VM-2000 and Trinzic Reporting TR-2000 series appliances For information about supported platforms see Supported Platforms on page 1 Note the following for IPv6 Grid support

                  bull If your Grid Master is configured with an IPv6 VIP all Grid Master Candidates must also include an IPv6 VIP For an HA pair both nodes of the HA pair must have IPv6 addresses for the Grid Master and the Grid Master Candidate

                  bull After you upgrade to NIOS 70x Infoblox recommends that you back up the configuration after you change network connectivity to a different mode (IPv4 IPv6 or IPv4 and IPv6 dual mode) Restoring an old backup by performing a forced restore may prevent some Grid members from rejoining the Grid after the restore

                  bull IPv6-only configuration does not support the following HSM LCD NAT groups OSPF and BGP

                  When you schedule a full upgrade from a previous release to NIOS 70x the following DNSSEC limitations are applicable

                  bull You cannot configure new settings that are added to the authoritative zone object while the upgrade is still in progress This restriction is not applicable to future upgrades

                  bull When you upgrade you can sign or unsign an authoritative zone only if the Grid Master Candidate and the associated serving members are upgraded This restriction is not applicable to future upgrades

                  bull An authoritative zone can have its KSK rollover only if the Grid Master Candidate and all the serving members are upgraded This restriction is not applicable to future upgrades

                  bull An authoritative zone can have its ZSK rollover by the daemon only if the Grid Master Candidate and all the serving members are upgraded This restriction is not applicable to future upgrades

                  bull You cannot delete keys while the upgrade is still in progress bull You cannot update DNSSEC related parameters at the member level while the upgrade is still in

                  progress Example rollover mechanism NSEC3 salt length and iterations and enable or disable automatic KSK rollover

                  NIOS 701 Release Notes

                  copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 10 of 21 400-0579-001 Rev A 1212015

                  For Cloud Network Automation bull After upgrading to NIOS 70x you must manually select the Delegated To Cloud Usage

                  and Owned By columns in the Data Management tab of Grid Manager to display relevant information This is applicable only if you have installed the Cloud Network Automation license on the Grid Master

                  BEFORE YOU INSTALL To ensure that new features and enhancements operate properly and smoothly Infoblox recommends that you evaluate the capacity on your Grid and review the upgrade guidelines before you upgrade from a previous NIOS release Infoblox recommends that administrators planning to perform an upgrade from a previous release create and archive a backup of the Infoblox appliance configuration and data before upgrading You can run an upgrade test before performing the actual upgrade Infoblox recommends that you run the upgrade test so you can resolve any potential data migration issues before the upgrade Following is a list of upgrade and revert paths You can also schedule a full upgrade from these releases 700 6122 and earlier 612x releases 6117 and earlier 611x releases 610201 and 610200 61010 and earlier 610x releases 69201-LD and 69200-LD 690 6813 and earlier 68x releases 678 and earlier 67x releases 6613 and earlier 66x releases Technical Support Infoblox technical support contact information

                  Telephone 1-888-463-6259 (toll-free US and Canada) +1-408-625-4200 ext 1

                  E-mail supportinfobloxcom

                  Web httpssupportinfobloxcom

                  GUI Requirements Grid Manager supports the following operating systems and browsers You must install and enable Javascript for Grid Manager to function properly Grid Manager supports only SSL version 3 and TLS version 1 connections Infoblox recommends that you use a computer that has a 2 GHz CPU and at least 1 GB of RAM

                  NIOS 701 Release Notes

                  copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 11 of 21 400-0579-001 Rev A 1212015

                  Infoblox supports the following browsers for Grid Manager

                  OS Browser Microsoft Windows 80 and 81reg Microsoft Internet Explorerreg 11x 10x

                  Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                  Microsoft Windows 7reg Microsoft Internet Explorerreg 11x 10x 9x and 8x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                  Microsoft Windows XPreg (SP2+) Microsoft Internet Explorer 7x and 8x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                  Red Hatreg Enterprise Linuxreg 7x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                  Red Hatreg Enterprise Linuxreg 6x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                  Red Hatreg Enterprise Linux 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                  Applereg Mac OS X 109x Safari 7x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                  Applereg Mac OS X 108x Safari 6x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                  Applereg Mac OS X 107x Safari 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                  Applereg Mac OS X 106x Safari 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                  NOTE Grid Manager fully supports Microsoft Internet Explorerreg 11x and 10x when you enable compatibility view in the browser Features in the Reporting tab may not function properly if you disable compatibility view In the browser go to Tools -gt Compatibility View to enable the feature When viewing Grid Manager set the screen resolution of your monitor as follows

                  Minimum resolution 1280 x 768 Recommended resolution 1280 x 1024 or better

                  Documentation You can download the Infoblox NIOS Administrator Guide from the appliance From Grid Manager expand the Help panel and then click Documentation -gt Admin Guide Training Training information is available at httpinterviewcentralcomeventsuploadsinfobloxloginhtml

                  NIOS 701 Release Notes

                  copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 12 of 21 400-0579-001 Rev A 1212015

                  ACCESSING GRID MANAGER Before you log in to Grid Manager ensure that you have installed your NIOS appliance as described in the installation guide or user guide that shipped with your product and configured it accordingly To log in to Grid Manager

                  1 Open an Internet browser window and enter httpsltIPv4 address or hostname of your NIOS appliancegt or https[IPv6 address] of your NIOS appliance The Grid Manager login page appears

                  2 Enter your user name and password and then click Login or press Enter The default user name is admin and password is infoblox

                  3 Read the Infoblox End-User License Agreement and click I Accept to proceed Grid Manager displays the Dashboard your home page in Grid Manager

                  ADDRESSED VULNERABILITIES This section lists security vulnerabilities that were addressed in the past 12 months For vulnerabilities that are not listed in this section refer to Infoblox KB 2899 For additional information about these vulnerabilities including their severities please refer to the National Vulnerability Database (NVD) at httpnvdnistgov The Infoblox Support website at httpssupportinfobloxcom also provides more information including vulnerabilities that do not affect Infoblox appliances CERT VULNERABILITY NOTE CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation CERT VULNERABILITY NOTE CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet CERT VULNERABILITY NOTE CVE-2014-3566 SSL3 is vulnerable to man-in-the-middle-attacks SSL3 is disabled in NIOS and connections must use TLSv1 (which is already used by all supported browsers)

                  CERT VULNERABILITY NOTE CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

                  CERT VULNERABILITY NOTE CVE-2014-7187 Off-by-one error in the read_token_word function in parsey in GNU BASH through v 43 allowed remote attackers to cause a denial of service (out-of-bounds array access and application crash) or possibly an unspecified impact through deeply nested for loops (also known as the word_lineno issue)

                  CERT VULNERABILITY NOTE CVE-2014-7186 The redirection implementation in parsey in GNU BASH through v 43 allowed remote attackers to cause a denial of service (out-of-bounds array access and application crash) or possibly an unspecified impact through the redir_stack issue

                  CERT VULNERABILITY NOTE CVE-2014-6271 CVE-3014-6277 CVE-2014-6278 AND CVE-2014-7169 GNU Bash through v 43 processed trailing strings after function definitions in the values of environment variables which allowed remote attackers to execute arbitrary code via a crafted environment (also known as the ShellShock vulnerability)

                  NIOS 701 Release Notes

                  copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 13 of 21 400-0579-001 Rev A 1212015

                  CERT VULNERABILITY NOTE CVE-2014-3470 Enabling anonymous ECDH cipher suites on TLS clients could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0224 A specially crafted handshake packet could force the use of weak keying material in the SSLTLS clients allowing a man-in-the-middle (MITM) attack to decrypt and modify traffic between a client and a server CERT VULNERABILITY NOTE CVE-2014-0221 Remote attackers could utilize DTLS hello message in an invalid DTLS handshake to cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0198 Enabling SSL_MODE_RELEASE_BUFFERS failed to manage buffer pointer during certain recursive calls that could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0195 Remote attackers could trigger buffer overrun attack through invalid DTLS fragments to an OpenSSL DTLS client or server resulting in a denial of service CERT VULNERABILITY NOTE CVE-2014-0591 A crafted query against an NSEC3-signed zone could cause the named process to terminate RESOLVED ISSUES The following issues were reported in previous NIOS releases and resolved in this release The resolved issues are listed by severity For descriptions of the severity levels refer to Severity Levels on page 16 Fixed in 701

                  ID Severity Summary

                  NIOS-51535 Major An IPv6 address configured before NIOS 640 was not properly preserved during an upgrade to NIOS 700 which caused an error during product initialization

                  Fixed in 700

                  ID Severity Summary

                  NIOS-50432 Critical Addressed zone journal file size issues that caused DNS service to slow down

                  NIOS-50295 Critical After a DIW import there were some missing delegations and records in the Grid data set

                  NIOS-50162 NIOS-50124

                  Critical Under certain circumstances intermittent DNS service interruptions occurred

                  ID Severity Summary

                  NIOS-51186 Major DNS failed to respond to some queries due to new limits exposed by CVE-2014-8500

                  NIOS-51051 Major DNS service interruptions occurred after changing RPZ records

                  NIOS 701 Release Notes

                  copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 14 of 21 400-0579-001 Rev A 1212015

                  NIOS-50894 Major Updated the Infoblox NIOS Administrator Guide to include information about virtual TFTP root is supported only for file downloads but not for file uploads using TFTP client

                  NIOS-50784 Major Addressed the following OpenVPN vulnerability CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet

                  NIOS-50532 Major Addressed the following vulnerabilities CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation

                  NIOS-50617 NIOS-49810

                  Major Grid Manager inappropriately marked IPv6 leases as having invalid MAC addresses

                  NIOS-50575 Major NIOS did not show the root domain for Microsoft servers belonging to two Domains in the same Forest

                  NIOS-50567 Major DIW failed to handle common CNAME records in different DNS views

                  NIOS-50453 Major Added information about HA Grid Master providing NTP service through VIP to the Infoblox NIOS Administrator Guide

                  NIOS-50402 Major Under certain circumstances NIOS returned option 43 in the response when users applied a non-global IPv4 option filter to a DHCP range

                  NIOS-50250 Major Unable to remove a Grid from the Master Grid

                  NIOS-50208 Major On some occasions the inheritance state for inherited extensible attributes was displayed as ldquooverriddenrdquo instead of ldquoinheritedrdquo

                  NIOS-50199 Major Unable to modify a DHCP scope that was synchronized from a Microsoft DHCP failover partner

                  NIOS-50171 Major Users could not convert a lease to a fixed address without the ldquoNetwork Discoveryrdquo permission which was not required

                  NIOS-50137 Major VLAN tagging was not functional properly on the HA interface

                  NIOS-50112 Major High CPU usage on Captive Portal caused by the ldquoomshellrdquo process

                  NIOS-50081 Major Unable to add the same IPv6 loopback address on other Grid members when the IPv6 address is already configured on the Grid Master

                  NIOS-50057 Major DHCP service interruptions occurred after an upgrade due to issues related to disabled Grid members in a MAC address filter

                  NIOS-50052 Major Addressed the following SSL 30 vulnerability CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

                  NIOS-49962 Major Unable to edit and save Upgrade Schedule

                  NIOS-49941 Major In a Multi-Grid configuration the Master Grid experienced high swap usage while processing a lot of data

                  NIOS-49935 Major Under certain circumstances exporting visible data from Grid Manager could fail for a zone

                  NIOS 701 Release Notes

                  copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 15 of 21 400-0579-001 Rev A 1212015

                  NIOS-49934 Major API On rare occasions searching with return_methods could result in incorrect PAPI results

                  NIOS-49847 Major The appliance returned an error when users tried to disable GSS-TSIG and remove the keys

                  NIOS-49826 Major Could not start DNS service on the Grid Secondary for a zone that had an external Primary while moving the LAN2 IP address from one member to the other

                  NIOS-49809 Major In a network template users could not save values for an extensible attribute that was a ldquolistrdquo type

                  NIOS-49735 Major The status of a Microsoft server was ldquoConnectingrdquo even when synchronization was in progress

                  NIOS-49505 Major High disk space usage was observed after enabling ldquoCapture DNS Queriesrdquo and ldquoCapture DNS Responsesrdquo

                  NIOS-49473 Major On rare occasions the Grid Master rebooted and went offline

                  NIOS-49349 Major The infobloxlog captured bloxTools user password in plain text

                  NIOS-49339 Major Grid Manager access was denied due to a missing object in the backup file

                  NIOS-49137 Major Advanced DNS Protection An unexpected HA failover occurred due to a general protection fault

                  NIOS-48437 Major DNS latency for DNS responses from cache was higher than usual for a duration of a couple seconds

                  NIOS-48009 Major A schedule upgrade did not function properly if the HA Grid Master had not replicated the schedule to the passive node before the upgrade started

                  NIOS-47994 Major DHCP service failed to start due to invalid DHCP option spaces defined in the DHCP configuration file

                  NIOS-50571 Minor Added descriptions about VLAN tag and DSCP support for TE-1400 series appliances to the Infoblox NIOS Administrator Guide

                  NIOS-50466 Minor DNS service startup took longer than expected due to journal file fragmentation

                  NIOS-50430 Minor Redefined the description for ldquoinfoblox-deny-rpzrdquo in the Infoblox NIOS Administrator Guide

                  NIOS-50401 Minor When associating a network with a Microsoft site an error message was displayed in the background instead of inside the editor

                  NIOS-50366 Minor Updated the CSV Import Reference to include the file format for ldquoresponsepolicyipaddressrdquo objects

                  NIOS-50267 Minor Unable to perform a discovery for a Microsoft managed subnet

                  NIOS-49986 Minor Updated IP addresses used in example in the Infoblox NIOS Administrator Guide

                  NIOS-49838 Minor Could not transfer support bundle using the transfer_supportbundle command

                  NIOS-49816 Minor The Discoverer field value was truncated in the IP MAP viewer under the Discovered Data tab

                  NIOS-49787 Minor The appliance logged excessive debugging messages

                  NIOS 701 Release Notes

                  copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 16 of 21 400-0579-001 Rev A 1212015

                  NIOS-48037 Minor Value for the extensible attribute ldquoSiterdquo was not displayed in the Lease Selector when

                  users tried to connect to an auto-provisioned member

                  NIOS-50399 Enhance Enhanced the ldquoConvertrdquo button to also appear in the IPAM home page

                  Severity Levels Severity Description

                  Critical Core network services are significantly impacted Major Network services are impacted but there is an available workaround Moderate Some loss of secondary services or configuration abilities Minor Minor functional or UI issue Enhance An enhancement to the product

                  KNOWN GENERAL ISSUES

                  ID Summary

                  NIOS-51323 DNS Traffic Control The appliance may return a timeout error while loading the Traffic Management tab in Grid Manager if you have configured health monitoring for a lot of DTC servers

                  NIOS-51287 Cloud Network Automation Modifying resource records through the cloud API will cause extensible attribute values to be removed

                  NIOS-51235 In a Multi-Grid configuration converting network connectivity for the Master Grid and its sub Grids to IPv6 only is not supported even though Grid Manager may allow you to do so

                  NIOS-51134 Infoblox appliances currently do not support HP passive copper cables

                  NIOS-51054 After you upgrade to NIOS 700 Infoblox recommends that you back up the configuration after you change network connectivity to a different mode (IPv4 IPv6 or IPv4 and IPv6 dual mode) Restoring an old backup by performing a forced restore may prevent some Grid members from rejoining the Grid after the restore

                  NIOS-50997 In this release the appliance does not automatically create a reverse-mapping zones for 1 for DNS servers that support IPv6

                  NIOS-50873 When you enable DNS and DHCP services for IPv6 only DDNS updates may not function properly for certain configurations Infoblox recommends that you do not enable DDNS updates in an IPv6-only Grid

                  NIOS-50859 Creating custom IPv6 NS records and pointing a zone to a particular IPv6 name server is not supported in this release

                  NIOS-50994 Cloud Network Automation When there is no tenant associated with a network or VM or if a network or VM is created by a cloud adapter but the tenant ID is not specified in the cloud API request the Name or ID column for the tenant or VM is left blank in Grid Manager which implies ldquoNArdquo or not applicable for the specified network or VM

                  NIOS 701 Release Notes

                  copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 17 of 21 400-0579-001 Rev A 1212015

                  NA Reporting When there is too much data being displayed in a graph data can overlap each other and make it difficult for viewing You can expand the graph to view specific data by stretching the graph on display However you will not be able to download the expanded graph in a PDF Workaround Right-click the expanded graph and then select This Frame -gt Print Frame from the drop-down menu to print the graph

                  NIOS-49238 Network Insight Under certain circumstances deleting networks may not remove the corresponding IP helper addresses from the device configuration

                  NIOS-49123 Network Insight When scheduling a discovery or port control blackout the scheduled time and time zone will always be standard time No time adjustments are made if the selected time zone is currently in daylight savings time and no adjustments are made when the time zone switches to daylight savings time

                  NIOS-49107 Network Insight If a recurring port control blackout is scheduled and it includes the current time port control tasks will be delayed during the current blackout period However you may not be warned until the next blackout period If a recurring discovery blackout is scheduled and it includes the current time the Discover Now functionality may not be blocked until the next blackout period

                  AUGUSTA2-1606

                  Network Insight Some devices such as the Cisco 3750X may report interfaces (that are not actually functional) as available through SNMP which could cause Port Control jobs on these non-functional interfaces to fail

                  NIOS-48944 Reporting When there are disconnected data points in the reporting data for reports (such as the DNS Query Rate by Query Type report) that support the stacked area panel type the stacked area that represents the disconnected data in the PDF report may not fill up accordingly and may cause it to look like a line chart when it is actually a stacked area chart Workaround Interpret the information correctly when reading the stacked area charts that contain disconnected data points

                  NIOS-48912 Network Insight Is a device is not connected to another host through a network the appliance will not be able to detect the Voice VLAN information

                  NIOS-48897 Network Insight Alcatel Omniswitches can operate in two modesmdashWorking mode and Certified mode Alcatel OmniSwitch 6000 devices must run in Working mode to allow Port Control jobs to work on these devices

                  NIOS-48704 Reporting When you configure a search for Top Devices Denied an IP Address using Member Network View Network and CIDR as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

                  NIOS-48560 Network Insight Before joining the Network Data Consolidator to the Grid use the CLI command reset net-automation database to ensure that previously discovered device information is removed from the database

                  NIOS-48399 You cannot restore the existing deleted resource records from the Recycle Bin after you promote a Grid Master Candidate to the Grid Master

                  NIOS-48311 On the IB-4010 appliance the maximum resource records allowed in a single signing zone is 800K not 25 of the object limit as in other platforms Exceeding this limit may result in a system restart

                  NIOS-48135 bloxTools data prior to NIOS 640 cannot be restored on NIOS 611x Workaround Upgrade to NIOS 64x first to get a backup before upgrading to NIOS 611x

                  NIOS 701 Release Notes

                  copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 18 of 21 400-0579-001 Rev A 1212015

                  NIOS-48030 You may not be able to log in to the bloxTools Workflow environment if you download the snapin-workflow file from the bloxTools Community site

                  NIOS-47959 Through the API and RESTful API users can add records and data without entering values for required extensible attributes Users cannot do the same through Grid Manager

                  NIOS-46356 An upgrade may fail if you clone reports and searches with duplicate names for the following reports DNS Query Rate by Server DNS Daily Query Rate by Server DNS Daily Peak Hour Query Rate by Server DHCP Device Operating System Trend DHCP Top Device Operating System and Traffic Rate

                  NIOS-46290 In some scenarios upgrading from NIOS 67x to NIOS 610x on an Infoblox-4030 appliance may require a manual restart to complete the upgrade

                  NIOS-46102 Advanced DNS Protection You may not be able to join an independent appliance to the Grid if the appliance has threat protection service enabled and only the LAN interface configured Workaround Disable threat protection service on the appliance before joining the Grid or configure the MGMT port and enable VPN on MGMT before joining the offline appliance to the Grid

                  NIOS-46051 Reporting When you configure a search for Threat Protect Event Count by Severity Trend using Member Category and Rule ID as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

                  NIOS-45906 Network Insight On rare occasions when there is incomplete inaccurate or misinterpreted data in discovered spanning tree information the appliance may not be able to determine the correct switch to which an end host is attached In this scenario the appliance may display inaccurate discovered data

                  NIOS-45904 Network Insight In Grid Manager the same end host on different VLANs may appear as duplicates that contain the same VLAN information

                  NIOS-45872 Content in the bloxHub widget on the Status Dashboard may not be displayed in certain versions of Google Chrome Mozilla FireFox and Microsoft Internet Explorer browsers due to security updates implemented by these browsers Workarounds For Chrome Click the security shield icon next to the URL and select Load unsafe script For FireFox Click the security shield icon next to the URL and select Disable Protection on This Page from the drop-down list For IE Click Show all content in the Only secure content is displayed message bar at the bottom of the page

                  NIOS-45598 Network Insight When a seed router is specified for an IP address that has already been assigned as a fixed address the IP will still be discovered even if the fixed address is excluded from discovery

                  NIOS-45233 Reporting When you use Microsoft Internet Explorer 10x and disable ldquoCompatibility Viewrdquo you may not be able to view reports in the Reporting tab Workaround In the Internet Explorer 10 browser go to Tools -gt Compatibility View to enable the feature

                  NIOS-45220 When you upgrade from NIOS 51r6-12 or earlier releases the Try Snapinstall option may not be available in the bloxTools environment after the upgrade Workaround Stop bloxTools service on the member console connect to the member through the CLI and execute the set bloxtools reset all command Once the reset process is complete restart the bloxTools service to access the Try Snapinstall option

                  NIOS 701 Release Notes

                  copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 19 of 21 400-0579-001 Rev A 1212015

                  VLAN-324 If you have assigned multiple VLANs to the LAN1 or LAN2 interfaces on the appliance you may receive messages about having ldquomultiple interfaces that match the same subnetrdquo during dhcpd process startups or restarts Note that these are not error messages and no actions are required

                  NIOS-44055 If you use certain versions of Mozilla FireFox to run Grid Manager the auto-detected time zone feature may not function properly even if you have enabled it in your User Profile

                  NIOS-43957 When you upgrade from NIOS 66x or earlier releases the email address in the SOA resource record that was entered in punycode will be converted into IDN (Internationalized Domain Name) after the upgrade Workaround Convert the IDN back to punycode using the IDN converter utility through Grid Manager

                  NIOS-43569 You may not be able to view reverse-mapping zones in an internal DNS view Workaround Set the table size to 10 in User Profile log out and then log back in to the system again

                  NIOS-41136 Reporting When you use certain versions of Mozilla Firefox and Google Chrome browsers on Windows 7 or Linux you may not be able to properly print reports

                  NIOS-39922 On Trinzic 2200 series appliances it may take up to three minutes for the LOM (Light On Management) LED to stop blinking after you have disabled the LOM feature

                  NIOS-38870 When you change the member type of an appliance from Infoblox to vNIOS the appliance might display an error message indicating that all network port settings of the vNIOS member must be changed to Automatic Workaround Through the Infoblox API use InfobloxGridMember and the functions lan_port_duplex( ) and lan_port_speed ( ) to change the network port settings for the vNIOS member

                  NIOS-38579 Reporting If you have a quick filter that includes a filter criterion with report comment equals to a value that NIOS automatically translates to another value the quick filter may not function properly after an upgrade to NIOS 65 or 66 NIOS automatically translates the following ldquoIPAM Utilizationrdquo to ldquoDDI Utilizationrdquo ldquoDNS Zone Statistics per DNS Viewrdquo to ldquoDNS Statistics per DNS Viewrdquo ldquoDNS Zone Statistics per DNS Zonerdquo to ldquoDNS Statistics per Zonerdquo ldquoDNS Member QPS Trendrdquo to ldquoDNS Query Rate by Serverrdquo and ldquoDNS Queries per Second Trendrdquo to ldquoDNS Query Rate by Query Typerdquo Workaround 1 Edit the original report comment values to match the translated values For example if you have entered ldquoIPAM Utilizationrdquo in the comment field of a report change it to ldquoDDI Utilizationrdquo Workaround 2 Edit the quick filter names to match the original comment values For example if you have entered ldquoQF1rdquo as a quick filter name and ldquoIPAM Utilizationrdquo as the report comment change the quick filter name to ldquoIPAM Utilizationrdquo

                  NIOS-37415 Users cannot execute Trinzic Automation Engine (TAE) if they log out of NetMRI during an active NetMRI session

                  NIOS-33600 There is an issue with SafeNet HSMs in that configuration changes do not immediately take effect such as when adding a new member to an existing SafeNet HSM Group deleting a client from the HSM or making member changes You can perform a forced restart of services to apply the changes immediately

                  NIOS-31864 Modifying a zone from a client increments the zonersquos serial number even if the zone contents did not change This causes unnecessary AXFRs to secondary servers and if the zone is served by a Microsoft Server that is managed in read-write mode it causes extra synchronizations as well

                  NIOS 701 Release Notes

                  copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 20 of 21 400-0579-001 Rev A 1212015

                  NIOS-31501 When a Microsoft server is the primary server for a zone and another Microsoft server is hosting the same zone as a stub zone and the NIOS appliance synchronizes DNS data with only one of these zones it will synchronize the zone as an authoritative or stub zone depending on which Microsoft server it synchronizes with first For more information please refer to KB article 17593

                  NIOS-25064 (45488)

                  If you configured a member DHCP server to authenticate DHCP clients with a RADIUS authentication server group and RADIUS is disabled (the server group is disabled all RADIUS servers in the group are disabled or the member DHCP server was not assigned an authentication server group) NAC filters with ldquodoes not equalrdquo rules will always match Workaround Do not disable RADIUS

                  NIOS-21512 (39917)

                  When you stop the DNS service of an independent appliance with temporary DNS and DHCP licenses Grid Manager displays the Restart Services panel regardless of which function you select

                  NIOS-21499 (38968)

                  An admin cannot display DNS views created by other admins during the same browser session To display the DNS views created by other admins you must log out and log in again

                  NIOS-19853 (31668)

                  Grid Manager does not display an error when you move a DNS view to a network view that contains a host record that has the same MAC address as a host record in the DNS view that is being moved

                  NIOS-19144 (30208)

                  Grid Manager does not sort columns correctly in the IPAM and Network list panels when the columns contain UTF-8 data

                  NIOS-18163 (27831)

                  The appliance allows users with read-only permission to A records to view DNSSEC resource records as well

                  NIOS-17636 (26233)

                  Syslog messages generated during a TFTP file transfer display the incorrect time zone

                  NIOS-17513 (26080)

                  Adding updating or deleting reverse zones could fail due to unsupported PTR records in the root zone

                  PAPIPASS-39

                  When you use Mozilla Firefox 16x 17x or Mozilla Firefox Beta 180b3 browser the hidden password in the Add Administrator Wizard of Grid Manager may disappear when you click the Password field after you have confirmed the password This is a known issue when you use Firefox browsers

                  MME-154 When a NIOS user deletes a Microsoft AD domainrsquos primary zones and subzones NIOS should display a more specific message warning users about the consequences of the operation instead of the general warning message it currently displays

                  MME-129 When a Microsoft admin creates a delegation on the Microsoft server and the delegation is synchronized to the NIOS appliance the glue A record of the delegation name server is synchronized to the appliance as a manually created record If on the NIOS appliance an admin changes the IP address on the NS record of the delegation name server two A glue records are generated one with the original address one with the new address NIOS retains the original glue A record because itrsquos marked as a manually created record and it can only be changed or deleted either manually on Grid Manager or through the API When synchronization occurs the Microsoft server correctly updates the existing glue A record and does not retain the original Note that NIOS retains the original A record only after the initial update If you update the A record again NIOS just updates the existing record without retaining the original

                  MME-23 NIOS displays an ldquoInternal Errorrdquo message when you try to apply a quick filter for a range that equals 1 when you display a range in the IPv4 Microsoft Superscopes tab

                  MME-6 If you add a hostname to the Target field of an SRV record on Grid Manager when the member synchronizes the SRV record to a Microsoft server it adds a new SRV record with the hostname instead of modifying the existing record

                  NIOS 701 Release Notes

                  copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 21 of 21 400-0579-001 Rev A 1212015

                  MSSS-11 (45296)

                  When you run a discovery on a network served by Microsoft servers and Grid Manager discovers a MAC address that does not match any of the fixed addresses associated with an IP address it reports a conflict and lists the associated fixed address objects in the Related Objects table You cannot select which fixed address to resolve in the Related Objects table You can only resolve the conflict for the first address

                  VNIOS-36 (41215)

                  If a virtual NIOS member does not start up due to a license violation Grid Manager displays the status of the vNIOS member as ldquoonlinerunningrdquo even though the member is not online

                  • INTRODUCTION
                    • Supported Platforms
                      • NEW FEATURES
                        • NIOS 700
                          • CHANGES TO DEFAULT BEHAVIOR
                            • NIOS 700
                            • NIOS 6x Releases
                              • CHANGES TO Infoblox API and RESTful API
                                • RESTful API Deprecation and Backward Compatibility Policy
                                • NIOS 70x
                                • NIOS 6x Releases
                                  • UPGRADE GUIDELINES
                                    • Upgrading to NIOS 70x
                                      • BEFORE YOU INSTALL
                                      • ACCESSING GRID MANAGER
                                      • ADDRESSED VULNERABILITIES
                                      • RESOLVED ISSUES
                                        • Fixed in 701
                                        • Fixed in 700
                                          • KNOWN GENERAL ISSUES

                    NIOS 701 Release Notes

                    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 10 of 21 400-0579-001 Rev A 1212015

                    For Cloud Network Automation bull After upgrading to NIOS 70x you must manually select the Delegated To Cloud Usage

                    and Owned By columns in the Data Management tab of Grid Manager to display relevant information This is applicable only if you have installed the Cloud Network Automation license on the Grid Master

                    BEFORE YOU INSTALL To ensure that new features and enhancements operate properly and smoothly Infoblox recommends that you evaluate the capacity on your Grid and review the upgrade guidelines before you upgrade from a previous NIOS release Infoblox recommends that administrators planning to perform an upgrade from a previous release create and archive a backup of the Infoblox appliance configuration and data before upgrading You can run an upgrade test before performing the actual upgrade Infoblox recommends that you run the upgrade test so you can resolve any potential data migration issues before the upgrade Following is a list of upgrade and revert paths You can also schedule a full upgrade from these releases 700 6122 and earlier 612x releases 6117 and earlier 611x releases 610201 and 610200 61010 and earlier 610x releases 69201-LD and 69200-LD 690 6813 and earlier 68x releases 678 and earlier 67x releases 6613 and earlier 66x releases Technical Support Infoblox technical support contact information

                    Telephone 1-888-463-6259 (toll-free US and Canada) +1-408-625-4200 ext 1

                    E-mail supportinfobloxcom

                    Web httpssupportinfobloxcom

                    GUI Requirements Grid Manager supports the following operating systems and browsers You must install and enable Javascript for Grid Manager to function properly Grid Manager supports only SSL version 3 and TLS version 1 connections Infoblox recommends that you use a computer that has a 2 GHz CPU and at least 1 GB of RAM

                    NIOS 701 Release Notes

                    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 11 of 21 400-0579-001 Rev A 1212015

                    Infoblox supports the following browsers for Grid Manager

                    OS Browser Microsoft Windows 80 and 81reg Microsoft Internet Explorerreg 11x 10x

                    Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                    Microsoft Windows 7reg Microsoft Internet Explorerreg 11x 10x 9x and 8x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                    Microsoft Windows XPreg (SP2+) Microsoft Internet Explorer 7x and 8x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                    Red Hatreg Enterprise Linuxreg 7x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                    Red Hatreg Enterprise Linuxreg 6x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                    Red Hatreg Enterprise Linux 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                    Applereg Mac OS X 109x Safari 7x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                    Applereg Mac OS X 108x Safari 6x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                    Applereg Mac OS X 107x Safari 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                    Applereg Mac OS X 106x Safari 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                    NOTE Grid Manager fully supports Microsoft Internet Explorerreg 11x and 10x when you enable compatibility view in the browser Features in the Reporting tab may not function properly if you disable compatibility view In the browser go to Tools -gt Compatibility View to enable the feature When viewing Grid Manager set the screen resolution of your monitor as follows

                    Minimum resolution 1280 x 768 Recommended resolution 1280 x 1024 or better

                    Documentation You can download the Infoblox NIOS Administrator Guide from the appliance From Grid Manager expand the Help panel and then click Documentation -gt Admin Guide Training Training information is available at httpinterviewcentralcomeventsuploadsinfobloxloginhtml

                    NIOS 701 Release Notes

                    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 12 of 21 400-0579-001 Rev A 1212015

                    ACCESSING GRID MANAGER Before you log in to Grid Manager ensure that you have installed your NIOS appliance as described in the installation guide or user guide that shipped with your product and configured it accordingly To log in to Grid Manager

                    1 Open an Internet browser window and enter httpsltIPv4 address or hostname of your NIOS appliancegt or https[IPv6 address] of your NIOS appliance The Grid Manager login page appears

                    2 Enter your user name and password and then click Login or press Enter The default user name is admin and password is infoblox

                    3 Read the Infoblox End-User License Agreement and click I Accept to proceed Grid Manager displays the Dashboard your home page in Grid Manager

                    ADDRESSED VULNERABILITIES This section lists security vulnerabilities that were addressed in the past 12 months For vulnerabilities that are not listed in this section refer to Infoblox KB 2899 For additional information about these vulnerabilities including their severities please refer to the National Vulnerability Database (NVD) at httpnvdnistgov The Infoblox Support website at httpssupportinfobloxcom also provides more information including vulnerabilities that do not affect Infoblox appliances CERT VULNERABILITY NOTE CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation CERT VULNERABILITY NOTE CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet CERT VULNERABILITY NOTE CVE-2014-3566 SSL3 is vulnerable to man-in-the-middle-attacks SSL3 is disabled in NIOS and connections must use TLSv1 (which is already used by all supported browsers)

                    CERT VULNERABILITY NOTE CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

                    CERT VULNERABILITY NOTE CVE-2014-7187 Off-by-one error in the read_token_word function in parsey in GNU BASH through v 43 allowed remote attackers to cause a denial of service (out-of-bounds array access and application crash) or possibly an unspecified impact through deeply nested for loops (also known as the word_lineno issue)

                    CERT VULNERABILITY NOTE CVE-2014-7186 The redirection implementation in parsey in GNU BASH through v 43 allowed remote attackers to cause a denial of service (out-of-bounds array access and application crash) or possibly an unspecified impact through the redir_stack issue

                    CERT VULNERABILITY NOTE CVE-2014-6271 CVE-3014-6277 CVE-2014-6278 AND CVE-2014-7169 GNU Bash through v 43 processed trailing strings after function definitions in the values of environment variables which allowed remote attackers to execute arbitrary code via a crafted environment (also known as the ShellShock vulnerability)

                    NIOS 701 Release Notes

                    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 13 of 21 400-0579-001 Rev A 1212015

                    CERT VULNERABILITY NOTE CVE-2014-3470 Enabling anonymous ECDH cipher suites on TLS clients could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0224 A specially crafted handshake packet could force the use of weak keying material in the SSLTLS clients allowing a man-in-the-middle (MITM) attack to decrypt and modify traffic between a client and a server CERT VULNERABILITY NOTE CVE-2014-0221 Remote attackers could utilize DTLS hello message in an invalid DTLS handshake to cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0198 Enabling SSL_MODE_RELEASE_BUFFERS failed to manage buffer pointer during certain recursive calls that could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0195 Remote attackers could trigger buffer overrun attack through invalid DTLS fragments to an OpenSSL DTLS client or server resulting in a denial of service CERT VULNERABILITY NOTE CVE-2014-0591 A crafted query against an NSEC3-signed zone could cause the named process to terminate RESOLVED ISSUES The following issues were reported in previous NIOS releases and resolved in this release The resolved issues are listed by severity For descriptions of the severity levels refer to Severity Levels on page 16 Fixed in 701

                    ID Severity Summary

                    NIOS-51535 Major An IPv6 address configured before NIOS 640 was not properly preserved during an upgrade to NIOS 700 which caused an error during product initialization

                    Fixed in 700

                    ID Severity Summary

                    NIOS-50432 Critical Addressed zone journal file size issues that caused DNS service to slow down

                    NIOS-50295 Critical After a DIW import there were some missing delegations and records in the Grid data set

                    NIOS-50162 NIOS-50124

                    Critical Under certain circumstances intermittent DNS service interruptions occurred

                    ID Severity Summary

                    NIOS-51186 Major DNS failed to respond to some queries due to new limits exposed by CVE-2014-8500

                    NIOS-51051 Major DNS service interruptions occurred after changing RPZ records

                    NIOS 701 Release Notes

                    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 14 of 21 400-0579-001 Rev A 1212015

                    NIOS-50894 Major Updated the Infoblox NIOS Administrator Guide to include information about virtual TFTP root is supported only for file downloads but not for file uploads using TFTP client

                    NIOS-50784 Major Addressed the following OpenVPN vulnerability CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet

                    NIOS-50532 Major Addressed the following vulnerabilities CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation

                    NIOS-50617 NIOS-49810

                    Major Grid Manager inappropriately marked IPv6 leases as having invalid MAC addresses

                    NIOS-50575 Major NIOS did not show the root domain for Microsoft servers belonging to two Domains in the same Forest

                    NIOS-50567 Major DIW failed to handle common CNAME records in different DNS views

                    NIOS-50453 Major Added information about HA Grid Master providing NTP service through VIP to the Infoblox NIOS Administrator Guide

                    NIOS-50402 Major Under certain circumstances NIOS returned option 43 in the response when users applied a non-global IPv4 option filter to a DHCP range

                    NIOS-50250 Major Unable to remove a Grid from the Master Grid

                    NIOS-50208 Major On some occasions the inheritance state for inherited extensible attributes was displayed as ldquooverriddenrdquo instead of ldquoinheritedrdquo

                    NIOS-50199 Major Unable to modify a DHCP scope that was synchronized from a Microsoft DHCP failover partner

                    NIOS-50171 Major Users could not convert a lease to a fixed address without the ldquoNetwork Discoveryrdquo permission which was not required

                    NIOS-50137 Major VLAN tagging was not functional properly on the HA interface

                    NIOS-50112 Major High CPU usage on Captive Portal caused by the ldquoomshellrdquo process

                    NIOS-50081 Major Unable to add the same IPv6 loopback address on other Grid members when the IPv6 address is already configured on the Grid Master

                    NIOS-50057 Major DHCP service interruptions occurred after an upgrade due to issues related to disabled Grid members in a MAC address filter

                    NIOS-50052 Major Addressed the following SSL 30 vulnerability CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

                    NIOS-49962 Major Unable to edit and save Upgrade Schedule

                    NIOS-49941 Major In a Multi-Grid configuration the Master Grid experienced high swap usage while processing a lot of data

                    NIOS-49935 Major Under certain circumstances exporting visible data from Grid Manager could fail for a zone

                    NIOS 701 Release Notes

                    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 15 of 21 400-0579-001 Rev A 1212015

                    NIOS-49934 Major API On rare occasions searching with return_methods could result in incorrect PAPI results

                    NIOS-49847 Major The appliance returned an error when users tried to disable GSS-TSIG and remove the keys

                    NIOS-49826 Major Could not start DNS service on the Grid Secondary for a zone that had an external Primary while moving the LAN2 IP address from one member to the other

                    NIOS-49809 Major In a network template users could not save values for an extensible attribute that was a ldquolistrdquo type

                    NIOS-49735 Major The status of a Microsoft server was ldquoConnectingrdquo even when synchronization was in progress

                    NIOS-49505 Major High disk space usage was observed after enabling ldquoCapture DNS Queriesrdquo and ldquoCapture DNS Responsesrdquo

                    NIOS-49473 Major On rare occasions the Grid Master rebooted and went offline

                    NIOS-49349 Major The infobloxlog captured bloxTools user password in plain text

                    NIOS-49339 Major Grid Manager access was denied due to a missing object in the backup file

                    NIOS-49137 Major Advanced DNS Protection An unexpected HA failover occurred due to a general protection fault

                    NIOS-48437 Major DNS latency for DNS responses from cache was higher than usual for a duration of a couple seconds

                    NIOS-48009 Major A schedule upgrade did not function properly if the HA Grid Master had not replicated the schedule to the passive node before the upgrade started

                    NIOS-47994 Major DHCP service failed to start due to invalid DHCP option spaces defined in the DHCP configuration file

                    NIOS-50571 Minor Added descriptions about VLAN tag and DSCP support for TE-1400 series appliances to the Infoblox NIOS Administrator Guide

                    NIOS-50466 Minor DNS service startup took longer than expected due to journal file fragmentation

                    NIOS-50430 Minor Redefined the description for ldquoinfoblox-deny-rpzrdquo in the Infoblox NIOS Administrator Guide

                    NIOS-50401 Minor When associating a network with a Microsoft site an error message was displayed in the background instead of inside the editor

                    NIOS-50366 Minor Updated the CSV Import Reference to include the file format for ldquoresponsepolicyipaddressrdquo objects

                    NIOS-50267 Minor Unable to perform a discovery for a Microsoft managed subnet

                    NIOS-49986 Minor Updated IP addresses used in example in the Infoblox NIOS Administrator Guide

                    NIOS-49838 Minor Could not transfer support bundle using the transfer_supportbundle command

                    NIOS-49816 Minor The Discoverer field value was truncated in the IP MAP viewer under the Discovered Data tab

                    NIOS-49787 Minor The appliance logged excessive debugging messages

                    NIOS 701 Release Notes

                    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 16 of 21 400-0579-001 Rev A 1212015

                    NIOS-48037 Minor Value for the extensible attribute ldquoSiterdquo was not displayed in the Lease Selector when

                    users tried to connect to an auto-provisioned member

                    NIOS-50399 Enhance Enhanced the ldquoConvertrdquo button to also appear in the IPAM home page

                    Severity Levels Severity Description

                    Critical Core network services are significantly impacted Major Network services are impacted but there is an available workaround Moderate Some loss of secondary services or configuration abilities Minor Minor functional or UI issue Enhance An enhancement to the product

                    KNOWN GENERAL ISSUES

                    ID Summary

                    NIOS-51323 DNS Traffic Control The appliance may return a timeout error while loading the Traffic Management tab in Grid Manager if you have configured health monitoring for a lot of DTC servers

                    NIOS-51287 Cloud Network Automation Modifying resource records through the cloud API will cause extensible attribute values to be removed

                    NIOS-51235 In a Multi-Grid configuration converting network connectivity for the Master Grid and its sub Grids to IPv6 only is not supported even though Grid Manager may allow you to do so

                    NIOS-51134 Infoblox appliances currently do not support HP passive copper cables

                    NIOS-51054 After you upgrade to NIOS 700 Infoblox recommends that you back up the configuration after you change network connectivity to a different mode (IPv4 IPv6 or IPv4 and IPv6 dual mode) Restoring an old backup by performing a forced restore may prevent some Grid members from rejoining the Grid after the restore

                    NIOS-50997 In this release the appliance does not automatically create a reverse-mapping zones for 1 for DNS servers that support IPv6

                    NIOS-50873 When you enable DNS and DHCP services for IPv6 only DDNS updates may not function properly for certain configurations Infoblox recommends that you do not enable DDNS updates in an IPv6-only Grid

                    NIOS-50859 Creating custom IPv6 NS records and pointing a zone to a particular IPv6 name server is not supported in this release

                    NIOS-50994 Cloud Network Automation When there is no tenant associated with a network or VM or if a network or VM is created by a cloud adapter but the tenant ID is not specified in the cloud API request the Name or ID column for the tenant or VM is left blank in Grid Manager which implies ldquoNArdquo or not applicable for the specified network or VM

                    NIOS 701 Release Notes

                    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 17 of 21 400-0579-001 Rev A 1212015

                    NA Reporting When there is too much data being displayed in a graph data can overlap each other and make it difficult for viewing You can expand the graph to view specific data by stretching the graph on display However you will not be able to download the expanded graph in a PDF Workaround Right-click the expanded graph and then select This Frame -gt Print Frame from the drop-down menu to print the graph

                    NIOS-49238 Network Insight Under certain circumstances deleting networks may not remove the corresponding IP helper addresses from the device configuration

                    NIOS-49123 Network Insight When scheduling a discovery or port control blackout the scheduled time and time zone will always be standard time No time adjustments are made if the selected time zone is currently in daylight savings time and no adjustments are made when the time zone switches to daylight savings time

                    NIOS-49107 Network Insight If a recurring port control blackout is scheduled and it includes the current time port control tasks will be delayed during the current blackout period However you may not be warned until the next blackout period If a recurring discovery blackout is scheduled and it includes the current time the Discover Now functionality may not be blocked until the next blackout period

                    AUGUSTA2-1606

                    Network Insight Some devices such as the Cisco 3750X may report interfaces (that are not actually functional) as available through SNMP which could cause Port Control jobs on these non-functional interfaces to fail

                    NIOS-48944 Reporting When there are disconnected data points in the reporting data for reports (such as the DNS Query Rate by Query Type report) that support the stacked area panel type the stacked area that represents the disconnected data in the PDF report may not fill up accordingly and may cause it to look like a line chart when it is actually a stacked area chart Workaround Interpret the information correctly when reading the stacked area charts that contain disconnected data points

                    NIOS-48912 Network Insight Is a device is not connected to another host through a network the appliance will not be able to detect the Voice VLAN information

                    NIOS-48897 Network Insight Alcatel Omniswitches can operate in two modesmdashWorking mode and Certified mode Alcatel OmniSwitch 6000 devices must run in Working mode to allow Port Control jobs to work on these devices

                    NIOS-48704 Reporting When you configure a search for Top Devices Denied an IP Address using Member Network View Network and CIDR as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

                    NIOS-48560 Network Insight Before joining the Network Data Consolidator to the Grid use the CLI command reset net-automation database to ensure that previously discovered device information is removed from the database

                    NIOS-48399 You cannot restore the existing deleted resource records from the Recycle Bin after you promote a Grid Master Candidate to the Grid Master

                    NIOS-48311 On the IB-4010 appliance the maximum resource records allowed in a single signing zone is 800K not 25 of the object limit as in other platforms Exceeding this limit may result in a system restart

                    NIOS-48135 bloxTools data prior to NIOS 640 cannot be restored on NIOS 611x Workaround Upgrade to NIOS 64x first to get a backup before upgrading to NIOS 611x

                    NIOS 701 Release Notes

                    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 18 of 21 400-0579-001 Rev A 1212015

                    NIOS-48030 You may not be able to log in to the bloxTools Workflow environment if you download the snapin-workflow file from the bloxTools Community site

                    NIOS-47959 Through the API and RESTful API users can add records and data without entering values for required extensible attributes Users cannot do the same through Grid Manager

                    NIOS-46356 An upgrade may fail if you clone reports and searches with duplicate names for the following reports DNS Query Rate by Server DNS Daily Query Rate by Server DNS Daily Peak Hour Query Rate by Server DHCP Device Operating System Trend DHCP Top Device Operating System and Traffic Rate

                    NIOS-46290 In some scenarios upgrading from NIOS 67x to NIOS 610x on an Infoblox-4030 appliance may require a manual restart to complete the upgrade

                    NIOS-46102 Advanced DNS Protection You may not be able to join an independent appliance to the Grid if the appliance has threat protection service enabled and only the LAN interface configured Workaround Disable threat protection service on the appliance before joining the Grid or configure the MGMT port and enable VPN on MGMT before joining the offline appliance to the Grid

                    NIOS-46051 Reporting When you configure a search for Threat Protect Event Count by Severity Trend using Member Category and Rule ID as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

                    NIOS-45906 Network Insight On rare occasions when there is incomplete inaccurate or misinterpreted data in discovered spanning tree information the appliance may not be able to determine the correct switch to which an end host is attached In this scenario the appliance may display inaccurate discovered data

                    NIOS-45904 Network Insight In Grid Manager the same end host on different VLANs may appear as duplicates that contain the same VLAN information

                    NIOS-45872 Content in the bloxHub widget on the Status Dashboard may not be displayed in certain versions of Google Chrome Mozilla FireFox and Microsoft Internet Explorer browsers due to security updates implemented by these browsers Workarounds For Chrome Click the security shield icon next to the URL and select Load unsafe script For FireFox Click the security shield icon next to the URL and select Disable Protection on This Page from the drop-down list For IE Click Show all content in the Only secure content is displayed message bar at the bottom of the page

                    NIOS-45598 Network Insight When a seed router is specified for an IP address that has already been assigned as a fixed address the IP will still be discovered even if the fixed address is excluded from discovery

                    NIOS-45233 Reporting When you use Microsoft Internet Explorer 10x and disable ldquoCompatibility Viewrdquo you may not be able to view reports in the Reporting tab Workaround In the Internet Explorer 10 browser go to Tools -gt Compatibility View to enable the feature

                    NIOS-45220 When you upgrade from NIOS 51r6-12 or earlier releases the Try Snapinstall option may not be available in the bloxTools environment after the upgrade Workaround Stop bloxTools service on the member console connect to the member through the CLI and execute the set bloxtools reset all command Once the reset process is complete restart the bloxTools service to access the Try Snapinstall option

                    NIOS 701 Release Notes

                    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 19 of 21 400-0579-001 Rev A 1212015

                    VLAN-324 If you have assigned multiple VLANs to the LAN1 or LAN2 interfaces on the appliance you may receive messages about having ldquomultiple interfaces that match the same subnetrdquo during dhcpd process startups or restarts Note that these are not error messages and no actions are required

                    NIOS-44055 If you use certain versions of Mozilla FireFox to run Grid Manager the auto-detected time zone feature may not function properly even if you have enabled it in your User Profile

                    NIOS-43957 When you upgrade from NIOS 66x or earlier releases the email address in the SOA resource record that was entered in punycode will be converted into IDN (Internationalized Domain Name) after the upgrade Workaround Convert the IDN back to punycode using the IDN converter utility through Grid Manager

                    NIOS-43569 You may not be able to view reverse-mapping zones in an internal DNS view Workaround Set the table size to 10 in User Profile log out and then log back in to the system again

                    NIOS-41136 Reporting When you use certain versions of Mozilla Firefox and Google Chrome browsers on Windows 7 or Linux you may not be able to properly print reports

                    NIOS-39922 On Trinzic 2200 series appliances it may take up to three minutes for the LOM (Light On Management) LED to stop blinking after you have disabled the LOM feature

                    NIOS-38870 When you change the member type of an appliance from Infoblox to vNIOS the appliance might display an error message indicating that all network port settings of the vNIOS member must be changed to Automatic Workaround Through the Infoblox API use InfobloxGridMember and the functions lan_port_duplex( ) and lan_port_speed ( ) to change the network port settings for the vNIOS member

                    NIOS-38579 Reporting If you have a quick filter that includes a filter criterion with report comment equals to a value that NIOS automatically translates to another value the quick filter may not function properly after an upgrade to NIOS 65 or 66 NIOS automatically translates the following ldquoIPAM Utilizationrdquo to ldquoDDI Utilizationrdquo ldquoDNS Zone Statistics per DNS Viewrdquo to ldquoDNS Statistics per DNS Viewrdquo ldquoDNS Zone Statistics per DNS Zonerdquo to ldquoDNS Statistics per Zonerdquo ldquoDNS Member QPS Trendrdquo to ldquoDNS Query Rate by Serverrdquo and ldquoDNS Queries per Second Trendrdquo to ldquoDNS Query Rate by Query Typerdquo Workaround 1 Edit the original report comment values to match the translated values For example if you have entered ldquoIPAM Utilizationrdquo in the comment field of a report change it to ldquoDDI Utilizationrdquo Workaround 2 Edit the quick filter names to match the original comment values For example if you have entered ldquoQF1rdquo as a quick filter name and ldquoIPAM Utilizationrdquo as the report comment change the quick filter name to ldquoIPAM Utilizationrdquo

                    NIOS-37415 Users cannot execute Trinzic Automation Engine (TAE) if they log out of NetMRI during an active NetMRI session

                    NIOS-33600 There is an issue with SafeNet HSMs in that configuration changes do not immediately take effect such as when adding a new member to an existing SafeNet HSM Group deleting a client from the HSM or making member changes You can perform a forced restart of services to apply the changes immediately

                    NIOS-31864 Modifying a zone from a client increments the zonersquos serial number even if the zone contents did not change This causes unnecessary AXFRs to secondary servers and if the zone is served by a Microsoft Server that is managed in read-write mode it causes extra synchronizations as well

                    NIOS 701 Release Notes

                    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 20 of 21 400-0579-001 Rev A 1212015

                    NIOS-31501 When a Microsoft server is the primary server for a zone and another Microsoft server is hosting the same zone as a stub zone and the NIOS appliance synchronizes DNS data with only one of these zones it will synchronize the zone as an authoritative or stub zone depending on which Microsoft server it synchronizes with first For more information please refer to KB article 17593

                    NIOS-25064 (45488)

                    If you configured a member DHCP server to authenticate DHCP clients with a RADIUS authentication server group and RADIUS is disabled (the server group is disabled all RADIUS servers in the group are disabled or the member DHCP server was not assigned an authentication server group) NAC filters with ldquodoes not equalrdquo rules will always match Workaround Do not disable RADIUS

                    NIOS-21512 (39917)

                    When you stop the DNS service of an independent appliance with temporary DNS and DHCP licenses Grid Manager displays the Restart Services panel regardless of which function you select

                    NIOS-21499 (38968)

                    An admin cannot display DNS views created by other admins during the same browser session To display the DNS views created by other admins you must log out and log in again

                    NIOS-19853 (31668)

                    Grid Manager does not display an error when you move a DNS view to a network view that contains a host record that has the same MAC address as a host record in the DNS view that is being moved

                    NIOS-19144 (30208)

                    Grid Manager does not sort columns correctly in the IPAM and Network list panels when the columns contain UTF-8 data

                    NIOS-18163 (27831)

                    The appliance allows users with read-only permission to A records to view DNSSEC resource records as well

                    NIOS-17636 (26233)

                    Syslog messages generated during a TFTP file transfer display the incorrect time zone

                    NIOS-17513 (26080)

                    Adding updating or deleting reverse zones could fail due to unsupported PTR records in the root zone

                    PAPIPASS-39

                    When you use Mozilla Firefox 16x 17x or Mozilla Firefox Beta 180b3 browser the hidden password in the Add Administrator Wizard of Grid Manager may disappear when you click the Password field after you have confirmed the password This is a known issue when you use Firefox browsers

                    MME-154 When a NIOS user deletes a Microsoft AD domainrsquos primary zones and subzones NIOS should display a more specific message warning users about the consequences of the operation instead of the general warning message it currently displays

                    MME-129 When a Microsoft admin creates a delegation on the Microsoft server and the delegation is synchronized to the NIOS appliance the glue A record of the delegation name server is synchronized to the appliance as a manually created record If on the NIOS appliance an admin changes the IP address on the NS record of the delegation name server two A glue records are generated one with the original address one with the new address NIOS retains the original glue A record because itrsquos marked as a manually created record and it can only be changed or deleted either manually on Grid Manager or through the API When synchronization occurs the Microsoft server correctly updates the existing glue A record and does not retain the original Note that NIOS retains the original A record only after the initial update If you update the A record again NIOS just updates the existing record without retaining the original

                    MME-23 NIOS displays an ldquoInternal Errorrdquo message when you try to apply a quick filter for a range that equals 1 when you display a range in the IPv4 Microsoft Superscopes tab

                    MME-6 If you add a hostname to the Target field of an SRV record on Grid Manager when the member synchronizes the SRV record to a Microsoft server it adds a new SRV record with the hostname instead of modifying the existing record

                    NIOS 701 Release Notes

                    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 21 of 21 400-0579-001 Rev A 1212015

                    MSSS-11 (45296)

                    When you run a discovery on a network served by Microsoft servers and Grid Manager discovers a MAC address that does not match any of the fixed addresses associated with an IP address it reports a conflict and lists the associated fixed address objects in the Related Objects table You cannot select which fixed address to resolve in the Related Objects table You can only resolve the conflict for the first address

                    VNIOS-36 (41215)

                    If a virtual NIOS member does not start up due to a license violation Grid Manager displays the status of the vNIOS member as ldquoonlinerunningrdquo even though the member is not online

                    • INTRODUCTION
                      • Supported Platforms
                        • NEW FEATURES
                          • NIOS 700
                            • CHANGES TO DEFAULT BEHAVIOR
                              • NIOS 700
                              • NIOS 6x Releases
                                • CHANGES TO Infoblox API and RESTful API
                                  • RESTful API Deprecation and Backward Compatibility Policy
                                  • NIOS 70x
                                  • NIOS 6x Releases
                                    • UPGRADE GUIDELINES
                                      • Upgrading to NIOS 70x
                                        • BEFORE YOU INSTALL
                                        • ACCESSING GRID MANAGER
                                        • ADDRESSED VULNERABILITIES
                                        • RESOLVED ISSUES
                                          • Fixed in 701
                                          • Fixed in 700
                                            • KNOWN GENERAL ISSUES

                      NIOS 701 Release Notes

                      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 11 of 21 400-0579-001 Rev A 1212015

                      Infoblox supports the following browsers for Grid Manager

                      OS Browser Microsoft Windows 80 and 81reg Microsoft Internet Explorerreg 11x 10x

                      Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                      Microsoft Windows 7reg Microsoft Internet Explorerreg 11x 10x 9x and 8x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                      Microsoft Windows XPreg (SP2+) Microsoft Internet Explorer 7x and 8x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                      Red Hatreg Enterprise Linuxreg 7x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                      Red Hatreg Enterprise Linuxreg 6x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                      Red Hatreg Enterprise Linux 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                      Applereg Mac OS X 109x Safari 7x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                      Applereg Mac OS X 108x Safari 6x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                      Applereg Mac OS X 107x Safari 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                      Applereg Mac OS X 106x Safari 5x Mozilla Firefox 32x 31x 25x 21x 16x and 10x Google Chrome 37x 36x 30x 27x 22x and 16x

                      NOTE Grid Manager fully supports Microsoft Internet Explorerreg 11x and 10x when you enable compatibility view in the browser Features in the Reporting tab may not function properly if you disable compatibility view In the browser go to Tools -gt Compatibility View to enable the feature When viewing Grid Manager set the screen resolution of your monitor as follows

                      Minimum resolution 1280 x 768 Recommended resolution 1280 x 1024 or better

                      Documentation You can download the Infoblox NIOS Administrator Guide from the appliance From Grid Manager expand the Help panel and then click Documentation -gt Admin Guide Training Training information is available at httpinterviewcentralcomeventsuploadsinfobloxloginhtml

                      NIOS 701 Release Notes

                      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 12 of 21 400-0579-001 Rev A 1212015

                      ACCESSING GRID MANAGER Before you log in to Grid Manager ensure that you have installed your NIOS appliance as described in the installation guide or user guide that shipped with your product and configured it accordingly To log in to Grid Manager

                      1 Open an Internet browser window and enter httpsltIPv4 address or hostname of your NIOS appliancegt or https[IPv6 address] of your NIOS appliance The Grid Manager login page appears

                      2 Enter your user name and password and then click Login or press Enter The default user name is admin and password is infoblox

                      3 Read the Infoblox End-User License Agreement and click I Accept to proceed Grid Manager displays the Dashboard your home page in Grid Manager

                      ADDRESSED VULNERABILITIES This section lists security vulnerabilities that were addressed in the past 12 months For vulnerabilities that are not listed in this section refer to Infoblox KB 2899 For additional information about these vulnerabilities including their severities please refer to the National Vulnerability Database (NVD) at httpnvdnistgov The Infoblox Support website at httpssupportinfobloxcom also provides more information including vulnerabilities that do not affect Infoblox appliances CERT VULNERABILITY NOTE CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation CERT VULNERABILITY NOTE CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet CERT VULNERABILITY NOTE CVE-2014-3566 SSL3 is vulnerable to man-in-the-middle-attacks SSL3 is disabled in NIOS and connections must use TLSv1 (which is already used by all supported browsers)

                      CERT VULNERABILITY NOTE CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

                      CERT VULNERABILITY NOTE CVE-2014-7187 Off-by-one error in the read_token_word function in parsey in GNU BASH through v 43 allowed remote attackers to cause a denial of service (out-of-bounds array access and application crash) or possibly an unspecified impact through deeply nested for loops (also known as the word_lineno issue)

                      CERT VULNERABILITY NOTE CVE-2014-7186 The redirection implementation in parsey in GNU BASH through v 43 allowed remote attackers to cause a denial of service (out-of-bounds array access and application crash) or possibly an unspecified impact through the redir_stack issue

                      CERT VULNERABILITY NOTE CVE-2014-6271 CVE-3014-6277 CVE-2014-6278 AND CVE-2014-7169 GNU Bash through v 43 processed trailing strings after function definitions in the values of environment variables which allowed remote attackers to execute arbitrary code via a crafted environment (also known as the ShellShock vulnerability)

                      NIOS 701 Release Notes

                      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 13 of 21 400-0579-001 Rev A 1212015

                      CERT VULNERABILITY NOTE CVE-2014-3470 Enabling anonymous ECDH cipher suites on TLS clients could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0224 A specially crafted handshake packet could force the use of weak keying material in the SSLTLS clients allowing a man-in-the-middle (MITM) attack to decrypt and modify traffic between a client and a server CERT VULNERABILITY NOTE CVE-2014-0221 Remote attackers could utilize DTLS hello message in an invalid DTLS handshake to cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0198 Enabling SSL_MODE_RELEASE_BUFFERS failed to manage buffer pointer during certain recursive calls that could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0195 Remote attackers could trigger buffer overrun attack through invalid DTLS fragments to an OpenSSL DTLS client or server resulting in a denial of service CERT VULNERABILITY NOTE CVE-2014-0591 A crafted query against an NSEC3-signed zone could cause the named process to terminate RESOLVED ISSUES The following issues were reported in previous NIOS releases and resolved in this release The resolved issues are listed by severity For descriptions of the severity levels refer to Severity Levels on page 16 Fixed in 701

                      ID Severity Summary

                      NIOS-51535 Major An IPv6 address configured before NIOS 640 was not properly preserved during an upgrade to NIOS 700 which caused an error during product initialization

                      Fixed in 700

                      ID Severity Summary

                      NIOS-50432 Critical Addressed zone journal file size issues that caused DNS service to slow down

                      NIOS-50295 Critical After a DIW import there were some missing delegations and records in the Grid data set

                      NIOS-50162 NIOS-50124

                      Critical Under certain circumstances intermittent DNS service interruptions occurred

                      ID Severity Summary

                      NIOS-51186 Major DNS failed to respond to some queries due to new limits exposed by CVE-2014-8500

                      NIOS-51051 Major DNS service interruptions occurred after changing RPZ records

                      NIOS 701 Release Notes

                      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 14 of 21 400-0579-001 Rev A 1212015

                      NIOS-50894 Major Updated the Infoblox NIOS Administrator Guide to include information about virtual TFTP root is supported only for file downloads but not for file uploads using TFTP client

                      NIOS-50784 Major Addressed the following OpenVPN vulnerability CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet

                      NIOS-50532 Major Addressed the following vulnerabilities CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation

                      NIOS-50617 NIOS-49810

                      Major Grid Manager inappropriately marked IPv6 leases as having invalid MAC addresses

                      NIOS-50575 Major NIOS did not show the root domain for Microsoft servers belonging to two Domains in the same Forest

                      NIOS-50567 Major DIW failed to handle common CNAME records in different DNS views

                      NIOS-50453 Major Added information about HA Grid Master providing NTP service through VIP to the Infoblox NIOS Administrator Guide

                      NIOS-50402 Major Under certain circumstances NIOS returned option 43 in the response when users applied a non-global IPv4 option filter to a DHCP range

                      NIOS-50250 Major Unable to remove a Grid from the Master Grid

                      NIOS-50208 Major On some occasions the inheritance state for inherited extensible attributes was displayed as ldquooverriddenrdquo instead of ldquoinheritedrdquo

                      NIOS-50199 Major Unable to modify a DHCP scope that was synchronized from a Microsoft DHCP failover partner

                      NIOS-50171 Major Users could not convert a lease to a fixed address without the ldquoNetwork Discoveryrdquo permission which was not required

                      NIOS-50137 Major VLAN tagging was not functional properly on the HA interface

                      NIOS-50112 Major High CPU usage on Captive Portal caused by the ldquoomshellrdquo process

                      NIOS-50081 Major Unable to add the same IPv6 loopback address on other Grid members when the IPv6 address is already configured on the Grid Master

                      NIOS-50057 Major DHCP service interruptions occurred after an upgrade due to issues related to disabled Grid members in a MAC address filter

                      NIOS-50052 Major Addressed the following SSL 30 vulnerability CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

                      NIOS-49962 Major Unable to edit and save Upgrade Schedule

                      NIOS-49941 Major In a Multi-Grid configuration the Master Grid experienced high swap usage while processing a lot of data

                      NIOS-49935 Major Under certain circumstances exporting visible data from Grid Manager could fail for a zone

                      NIOS 701 Release Notes

                      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 15 of 21 400-0579-001 Rev A 1212015

                      NIOS-49934 Major API On rare occasions searching with return_methods could result in incorrect PAPI results

                      NIOS-49847 Major The appliance returned an error when users tried to disable GSS-TSIG and remove the keys

                      NIOS-49826 Major Could not start DNS service on the Grid Secondary for a zone that had an external Primary while moving the LAN2 IP address from one member to the other

                      NIOS-49809 Major In a network template users could not save values for an extensible attribute that was a ldquolistrdquo type

                      NIOS-49735 Major The status of a Microsoft server was ldquoConnectingrdquo even when synchronization was in progress

                      NIOS-49505 Major High disk space usage was observed after enabling ldquoCapture DNS Queriesrdquo and ldquoCapture DNS Responsesrdquo

                      NIOS-49473 Major On rare occasions the Grid Master rebooted and went offline

                      NIOS-49349 Major The infobloxlog captured bloxTools user password in plain text

                      NIOS-49339 Major Grid Manager access was denied due to a missing object in the backup file

                      NIOS-49137 Major Advanced DNS Protection An unexpected HA failover occurred due to a general protection fault

                      NIOS-48437 Major DNS latency for DNS responses from cache was higher than usual for a duration of a couple seconds

                      NIOS-48009 Major A schedule upgrade did not function properly if the HA Grid Master had not replicated the schedule to the passive node before the upgrade started

                      NIOS-47994 Major DHCP service failed to start due to invalid DHCP option spaces defined in the DHCP configuration file

                      NIOS-50571 Minor Added descriptions about VLAN tag and DSCP support for TE-1400 series appliances to the Infoblox NIOS Administrator Guide

                      NIOS-50466 Minor DNS service startup took longer than expected due to journal file fragmentation

                      NIOS-50430 Minor Redefined the description for ldquoinfoblox-deny-rpzrdquo in the Infoblox NIOS Administrator Guide

                      NIOS-50401 Minor When associating a network with a Microsoft site an error message was displayed in the background instead of inside the editor

                      NIOS-50366 Minor Updated the CSV Import Reference to include the file format for ldquoresponsepolicyipaddressrdquo objects

                      NIOS-50267 Minor Unable to perform a discovery for a Microsoft managed subnet

                      NIOS-49986 Minor Updated IP addresses used in example in the Infoblox NIOS Administrator Guide

                      NIOS-49838 Minor Could not transfer support bundle using the transfer_supportbundle command

                      NIOS-49816 Minor The Discoverer field value was truncated in the IP MAP viewer under the Discovered Data tab

                      NIOS-49787 Minor The appliance logged excessive debugging messages

                      NIOS 701 Release Notes

                      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 16 of 21 400-0579-001 Rev A 1212015

                      NIOS-48037 Minor Value for the extensible attribute ldquoSiterdquo was not displayed in the Lease Selector when

                      users tried to connect to an auto-provisioned member

                      NIOS-50399 Enhance Enhanced the ldquoConvertrdquo button to also appear in the IPAM home page

                      Severity Levels Severity Description

                      Critical Core network services are significantly impacted Major Network services are impacted but there is an available workaround Moderate Some loss of secondary services or configuration abilities Minor Minor functional or UI issue Enhance An enhancement to the product

                      KNOWN GENERAL ISSUES

                      ID Summary

                      NIOS-51323 DNS Traffic Control The appliance may return a timeout error while loading the Traffic Management tab in Grid Manager if you have configured health monitoring for a lot of DTC servers

                      NIOS-51287 Cloud Network Automation Modifying resource records through the cloud API will cause extensible attribute values to be removed

                      NIOS-51235 In a Multi-Grid configuration converting network connectivity for the Master Grid and its sub Grids to IPv6 only is not supported even though Grid Manager may allow you to do so

                      NIOS-51134 Infoblox appliances currently do not support HP passive copper cables

                      NIOS-51054 After you upgrade to NIOS 700 Infoblox recommends that you back up the configuration after you change network connectivity to a different mode (IPv4 IPv6 or IPv4 and IPv6 dual mode) Restoring an old backup by performing a forced restore may prevent some Grid members from rejoining the Grid after the restore

                      NIOS-50997 In this release the appliance does not automatically create a reverse-mapping zones for 1 for DNS servers that support IPv6

                      NIOS-50873 When you enable DNS and DHCP services for IPv6 only DDNS updates may not function properly for certain configurations Infoblox recommends that you do not enable DDNS updates in an IPv6-only Grid

                      NIOS-50859 Creating custom IPv6 NS records and pointing a zone to a particular IPv6 name server is not supported in this release

                      NIOS-50994 Cloud Network Automation When there is no tenant associated with a network or VM or if a network or VM is created by a cloud adapter but the tenant ID is not specified in the cloud API request the Name or ID column for the tenant or VM is left blank in Grid Manager which implies ldquoNArdquo or not applicable for the specified network or VM

                      NIOS 701 Release Notes

                      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 17 of 21 400-0579-001 Rev A 1212015

                      NA Reporting When there is too much data being displayed in a graph data can overlap each other and make it difficult for viewing You can expand the graph to view specific data by stretching the graph on display However you will not be able to download the expanded graph in a PDF Workaround Right-click the expanded graph and then select This Frame -gt Print Frame from the drop-down menu to print the graph

                      NIOS-49238 Network Insight Under certain circumstances deleting networks may not remove the corresponding IP helper addresses from the device configuration

                      NIOS-49123 Network Insight When scheduling a discovery or port control blackout the scheduled time and time zone will always be standard time No time adjustments are made if the selected time zone is currently in daylight savings time and no adjustments are made when the time zone switches to daylight savings time

                      NIOS-49107 Network Insight If a recurring port control blackout is scheduled and it includes the current time port control tasks will be delayed during the current blackout period However you may not be warned until the next blackout period If a recurring discovery blackout is scheduled and it includes the current time the Discover Now functionality may not be blocked until the next blackout period

                      AUGUSTA2-1606

                      Network Insight Some devices such as the Cisco 3750X may report interfaces (that are not actually functional) as available through SNMP which could cause Port Control jobs on these non-functional interfaces to fail

                      NIOS-48944 Reporting When there are disconnected data points in the reporting data for reports (such as the DNS Query Rate by Query Type report) that support the stacked area panel type the stacked area that represents the disconnected data in the PDF report may not fill up accordingly and may cause it to look like a line chart when it is actually a stacked area chart Workaround Interpret the information correctly when reading the stacked area charts that contain disconnected data points

                      NIOS-48912 Network Insight Is a device is not connected to another host through a network the appliance will not be able to detect the Voice VLAN information

                      NIOS-48897 Network Insight Alcatel Omniswitches can operate in two modesmdashWorking mode and Certified mode Alcatel OmniSwitch 6000 devices must run in Working mode to allow Port Control jobs to work on these devices

                      NIOS-48704 Reporting When you configure a search for Top Devices Denied an IP Address using Member Network View Network and CIDR as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

                      NIOS-48560 Network Insight Before joining the Network Data Consolidator to the Grid use the CLI command reset net-automation database to ensure that previously discovered device information is removed from the database

                      NIOS-48399 You cannot restore the existing deleted resource records from the Recycle Bin after you promote a Grid Master Candidate to the Grid Master

                      NIOS-48311 On the IB-4010 appliance the maximum resource records allowed in a single signing zone is 800K not 25 of the object limit as in other platforms Exceeding this limit may result in a system restart

                      NIOS-48135 bloxTools data prior to NIOS 640 cannot be restored on NIOS 611x Workaround Upgrade to NIOS 64x first to get a backup before upgrading to NIOS 611x

                      NIOS 701 Release Notes

                      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 18 of 21 400-0579-001 Rev A 1212015

                      NIOS-48030 You may not be able to log in to the bloxTools Workflow environment if you download the snapin-workflow file from the bloxTools Community site

                      NIOS-47959 Through the API and RESTful API users can add records and data without entering values for required extensible attributes Users cannot do the same through Grid Manager

                      NIOS-46356 An upgrade may fail if you clone reports and searches with duplicate names for the following reports DNS Query Rate by Server DNS Daily Query Rate by Server DNS Daily Peak Hour Query Rate by Server DHCP Device Operating System Trend DHCP Top Device Operating System and Traffic Rate

                      NIOS-46290 In some scenarios upgrading from NIOS 67x to NIOS 610x on an Infoblox-4030 appliance may require a manual restart to complete the upgrade

                      NIOS-46102 Advanced DNS Protection You may not be able to join an independent appliance to the Grid if the appliance has threat protection service enabled and only the LAN interface configured Workaround Disable threat protection service on the appliance before joining the Grid or configure the MGMT port and enable VPN on MGMT before joining the offline appliance to the Grid

                      NIOS-46051 Reporting When you configure a search for Threat Protect Event Count by Severity Trend using Member Category and Rule ID as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

                      NIOS-45906 Network Insight On rare occasions when there is incomplete inaccurate or misinterpreted data in discovered spanning tree information the appliance may not be able to determine the correct switch to which an end host is attached In this scenario the appliance may display inaccurate discovered data

                      NIOS-45904 Network Insight In Grid Manager the same end host on different VLANs may appear as duplicates that contain the same VLAN information

                      NIOS-45872 Content in the bloxHub widget on the Status Dashboard may not be displayed in certain versions of Google Chrome Mozilla FireFox and Microsoft Internet Explorer browsers due to security updates implemented by these browsers Workarounds For Chrome Click the security shield icon next to the URL and select Load unsafe script For FireFox Click the security shield icon next to the URL and select Disable Protection on This Page from the drop-down list For IE Click Show all content in the Only secure content is displayed message bar at the bottom of the page

                      NIOS-45598 Network Insight When a seed router is specified for an IP address that has already been assigned as a fixed address the IP will still be discovered even if the fixed address is excluded from discovery

                      NIOS-45233 Reporting When you use Microsoft Internet Explorer 10x and disable ldquoCompatibility Viewrdquo you may not be able to view reports in the Reporting tab Workaround In the Internet Explorer 10 browser go to Tools -gt Compatibility View to enable the feature

                      NIOS-45220 When you upgrade from NIOS 51r6-12 or earlier releases the Try Snapinstall option may not be available in the bloxTools environment after the upgrade Workaround Stop bloxTools service on the member console connect to the member through the CLI and execute the set bloxtools reset all command Once the reset process is complete restart the bloxTools service to access the Try Snapinstall option

                      NIOS 701 Release Notes

                      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 19 of 21 400-0579-001 Rev A 1212015

                      VLAN-324 If you have assigned multiple VLANs to the LAN1 or LAN2 interfaces on the appliance you may receive messages about having ldquomultiple interfaces that match the same subnetrdquo during dhcpd process startups or restarts Note that these are not error messages and no actions are required

                      NIOS-44055 If you use certain versions of Mozilla FireFox to run Grid Manager the auto-detected time zone feature may not function properly even if you have enabled it in your User Profile

                      NIOS-43957 When you upgrade from NIOS 66x or earlier releases the email address in the SOA resource record that was entered in punycode will be converted into IDN (Internationalized Domain Name) after the upgrade Workaround Convert the IDN back to punycode using the IDN converter utility through Grid Manager

                      NIOS-43569 You may not be able to view reverse-mapping zones in an internal DNS view Workaround Set the table size to 10 in User Profile log out and then log back in to the system again

                      NIOS-41136 Reporting When you use certain versions of Mozilla Firefox and Google Chrome browsers on Windows 7 or Linux you may not be able to properly print reports

                      NIOS-39922 On Trinzic 2200 series appliances it may take up to three minutes for the LOM (Light On Management) LED to stop blinking after you have disabled the LOM feature

                      NIOS-38870 When you change the member type of an appliance from Infoblox to vNIOS the appliance might display an error message indicating that all network port settings of the vNIOS member must be changed to Automatic Workaround Through the Infoblox API use InfobloxGridMember and the functions lan_port_duplex( ) and lan_port_speed ( ) to change the network port settings for the vNIOS member

                      NIOS-38579 Reporting If you have a quick filter that includes a filter criterion with report comment equals to a value that NIOS automatically translates to another value the quick filter may not function properly after an upgrade to NIOS 65 or 66 NIOS automatically translates the following ldquoIPAM Utilizationrdquo to ldquoDDI Utilizationrdquo ldquoDNS Zone Statistics per DNS Viewrdquo to ldquoDNS Statistics per DNS Viewrdquo ldquoDNS Zone Statistics per DNS Zonerdquo to ldquoDNS Statistics per Zonerdquo ldquoDNS Member QPS Trendrdquo to ldquoDNS Query Rate by Serverrdquo and ldquoDNS Queries per Second Trendrdquo to ldquoDNS Query Rate by Query Typerdquo Workaround 1 Edit the original report comment values to match the translated values For example if you have entered ldquoIPAM Utilizationrdquo in the comment field of a report change it to ldquoDDI Utilizationrdquo Workaround 2 Edit the quick filter names to match the original comment values For example if you have entered ldquoQF1rdquo as a quick filter name and ldquoIPAM Utilizationrdquo as the report comment change the quick filter name to ldquoIPAM Utilizationrdquo

                      NIOS-37415 Users cannot execute Trinzic Automation Engine (TAE) if they log out of NetMRI during an active NetMRI session

                      NIOS-33600 There is an issue with SafeNet HSMs in that configuration changes do not immediately take effect such as when adding a new member to an existing SafeNet HSM Group deleting a client from the HSM or making member changes You can perform a forced restart of services to apply the changes immediately

                      NIOS-31864 Modifying a zone from a client increments the zonersquos serial number even if the zone contents did not change This causes unnecessary AXFRs to secondary servers and if the zone is served by a Microsoft Server that is managed in read-write mode it causes extra synchronizations as well

                      NIOS 701 Release Notes

                      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 20 of 21 400-0579-001 Rev A 1212015

                      NIOS-31501 When a Microsoft server is the primary server for a zone and another Microsoft server is hosting the same zone as a stub zone and the NIOS appliance synchronizes DNS data with only one of these zones it will synchronize the zone as an authoritative or stub zone depending on which Microsoft server it synchronizes with first For more information please refer to KB article 17593

                      NIOS-25064 (45488)

                      If you configured a member DHCP server to authenticate DHCP clients with a RADIUS authentication server group and RADIUS is disabled (the server group is disabled all RADIUS servers in the group are disabled or the member DHCP server was not assigned an authentication server group) NAC filters with ldquodoes not equalrdquo rules will always match Workaround Do not disable RADIUS

                      NIOS-21512 (39917)

                      When you stop the DNS service of an independent appliance with temporary DNS and DHCP licenses Grid Manager displays the Restart Services panel regardless of which function you select

                      NIOS-21499 (38968)

                      An admin cannot display DNS views created by other admins during the same browser session To display the DNS views created by other admins you must log out and log in again

                      NIOS-19853 (31668)

                      Grid Manager does not display an error when you move a DNS view to a network view that contains a host record that has the same MAC address as a host record in the DNS view that is being moved

                      NIOS-19144 (30208)

                      Grid Manager does not sort columns correctly in the IPAM and Network list panels when the columns contain UTF-8 data

                      NIOS-18163 (27831)

                      The appliance allows users with read-only permission to A records to view DNSSEC resource records as well

                      NIOS-17636 (26233)

                      Syslog messages generated during a TFTP file transfer display the incorrect time zone

                      NIOS-17513 (26080)

                      Adding updating or deleting reverse zones could fail due to unsupported PTR records in the root zone

                      PAPIPASS-39

                      When you use Mozilla Firefox 16x 17x or Mozilla Firefox Beta 180b3 browser the hidden password in the Add Administrator Wizard of Grid Manager may disappear when you click the Password field after you have confirmed the password This is a known issue when you use Firefox browsers

                      MME-154 When a NIOS user deletes a Microsoft AD domainrsquos primary zones and subzones NIOS should display a more specific message warning users about the consequences of the operation instead of the general warning message it currently displays

                      MME-129 When a Microsoft admin creates a delegation on the Microsoft server and the delegation is synchronized to the NIOS appliance the glue A record of the delegation name server is synchronized to the appliance as a manually created record If on the NIOS appliance an admin changes the IP address on the NS record of the delegation name server two A glue records are generated one with the original address one with the new address NIOS retains the original glue A record because itrsquos marked as a manually created record and it can only be changed or deleted either manually on Grid Manager or through the API When synchronization occurs the Microsoft server correctly updates the existing glue A record and does not retain the original Note that NIOS retains the original A record only after the initial update If you update the A record again NIOS just updates the existing record without retaining the original

                      MME-23 NIOS displays an ldquoInternal Errorrdquo message when you try to apply a quick filter for a range that equals 1 when you display a range in the IPv4 Microsoft Superscopes tab

                      MME-6 If you add a hostname to the Target field of an SRV record on Grid Manager when the member synchronizes the SRV record to a Microsoft server it adds a new SRV record with the hostname instead of modifying the existing record

                      NIOS 701 Release Notes

                      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 21 of 21 400-0579-001 Rev A 1212015

                      MSSS-11 (45296)

                      When you run a discovery on a network served by Microsoft servers and Grid Manager discovers a MAC address that does not match any of the fixed addresses associated with an IP address it reports a conflict and lists the associated fixed address objects in the Related Objects table You cannot select which fixed address to resolve in the Related Objects table You can only resolve the conflict for the first address

                      VNIOS-36 (41215)

                      If a virtual NIOS member does not start up due to a license violation Grid Manager displays the status of the vNIOS member as ldquoonlinerunningrdquo even though the member is not online

                      • INTRODUCTION
                        • Supported Platforms
                          • NEW FEATURES
                            • NIOS 700
                              • CHANGES TO DEFAULT BEHAVIOR
                                • NIOS 700
                                • NIOS 6x Releases
                                  • CHANGES TO Infoblox API and RESTful API
                                    • RESTful API Deprecation and Backward Compatibility Policy
                                    • NIOS 70x
                                    • NIOS 6x Releases
                                      • UPGRADE GUIDELINES
                                        • Upgrading to NIOS 70x
                                          • BEFORE YOU INSTALL
                                          • ACCESSING GRID MANAGER
                                          • ADDRESSED VULNERABILITIES
                                          • RESOLVED ISSUES
                                            • Fixed in 701
                                            • Fixed in 700
                                              • KNOWN GENERAL ISSUES

                        NIOS 701 Release Notes

                        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 12 of 21 400-0579-001 Rev A 1212015

                        ACCESSING GRID MANAGER Before you log in to Grid Manager ensure that you have installed your NIOS appliance as described in the installation guide or user guide that shipped with your product and configured it accordingly To log in to Grid Manager

                        1 Open an Internet browser window and enter httpsltIPv4 address or hostname of your NIOS appliancegt or https[IPv6 address] of your NIOS appliance The Grid Manager login page appears

                        2 Enter your user name and password and then click Login or press Enter The default user name is admin and password is infoblox

                        3 Read the Infoblox End-User License Agreement and click I Accept to proceed Grid Manager displays the Dashboard your home page in Grid Manager

                        ADDRESSED VULNERABILITIES This section lists security vulnerabilities that were addressed in the past 12 months For vulnerabilities that are not listed in this section refer to Infoblox KB 2899 For additional information about these vulnerabilities including their severities please refer to the National Vulnerability Database (NVD) at httpnvdnistgov The Infoblox Support website at httpssupportinfobloxcom also provides more information including vulnerabilities that do not affect Infoblox appliances CERT VULNERABILITY NOTE CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation CERT VULNERABILITY NOTE CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet CERT VULNERABILITY NOTE CVE-2014-3566 SSL3 is vulnerable to man-in-the-middle-attacks SSL3 is disabled in NIOS and connections must use TLSv1 (which is already used by all supported browsers)

                        CERT VULNERABILITY NOTE CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

                        CERT VULNERABILITY NOTE CVE-2014-7187 Off-by-one error in the read_token_word function in parsey in GNU BASH through v 43 allowed remote attackers to cause a denial of service (out-of-bounds array access and application crash) or possibly an unspecified impact through deeply nested for loops (also known as the word_lineno issue)

                        CERT VULNERABILITY NOTE CVE-2014-7186 The redirection implementation in parsey in GNU BASH through v 43 allowed remote attackers to cause a denial of service (out-of-bounds array access and application crash) or possibly an unspecified impact through the redir_stack issue

                        CERT VULNERABILITY NOTE CVE-2014-6271 CVE-3014-6277 CVE-2014-6278 AND CVE-2014-7169 GNU Bash through v 43 processed trailing strings after function definitions in the values of environment variables which allowed remote attackers to execute arbitrary code via a crafted environment (also known as the ShellShock vulnerability)

                        NIOS 701 Release Notes

                        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 13 of 21 400-0579-001 Rev A 1212015

                        CERT VULNERABILITY NOTE CVE-2014-3470 Enabling anonymous ECDH cipher suites on TLS clients could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0224 A specially crafted handshake packet could force the use of weak keying material in the SSLTLS clients allowing a man-in-the-middle (MITM) attack to decrypt and modify traffic between a client and a server CERT VULNERABILITY NOTE CVE-2014-0221 Remote attackers could utilize DTLS hello message in an invalid DTLS handshake to cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0198 Enabling SSL_MODE_RELEASE_BUFFERS failed to manage buffer pointer during certain recursive calls that could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0195 Remote attackers could trigger buffer overrun attack through invalid DTLS fragments to an OpenSSL DTLS client or server resulting in a denial of service CERT VULNERABILITY NOTE CVE-2014-0591 A crafted query against an NSEC3-signed zone could cause the named process to terminate RESOLVED ISSUES The following issues were reported in previous NIOS releases and resolved in this release The resolved issues are listed by severity For descriptions of the severity levels refer to Severity Levels on page 16 Fixed in 701

                        ID Severity Summary

                        NIOS-51535 Major An IPv6 address configured before NIOS 640 was not properly preserved during an upgrade to NIOS 700 which caused an error during product initialization

                        Fixed in 700

                        ID Severity Summary

                        NIOS-50432 Critical Addressed zone journal file size issues that caused DNS service to slow down

                        NIOS-50295 Critical After a DIW import there were some missing delegations and records in the Grid data set

                        NIOS-50162 NIOS-50124

                        Critical Under certain circumstances intermittent DNS service interruptions occurred

                        ID Severity Summary

                        NIOS-51186 Major DNS failed to respond to some queries due to new limits exposed by CVE-2014-8500

                        NIOS-51051 Major DNS service interruptions occurred after changing RPZ records

                        NIOS 701 Release Notes

                        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 14 of 21 400-0579-001 Rev A 1212015

                        NIOS-50894 Major Updated the Infoblox NIOS Administrator Guide to include information about virtual TFTP root is supported only for file downloads but not for file uploads using TFTP client

                        NIOS-50784 Major Addressed the following OpenVPN vulnerability CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet

                        NIOS-50532 Major Addressed the following vulnerabilities CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation

                        NIOS-50617 NIOS-49810

                        Major Grid Manager inappropriately marked IPv6 leases as having invalid MAC addresses

                        NIOS-50575 Major NIOS did not show the root domain for Microsoft servers belonging to two Domains in the same Forest

                        NIOS-50567 Major DIW failed to handle common CNAME records in different DNS views

                        NIOS-50453 Major Added information about HA Grid Master providing NTP service through VIP to the Infoblox NIOS Administrator Guide

                        NIOS-50402 Major Under certain circumstances NIOS returned option 43 in the response when users applied a non-global IPv4 option filter to a DHCP range

                        NIOS-50250 Major Unable to remove a Grid from the Master Grid

                        NIOS-50208 Major On some occasions the inheritance state for inherited extensible attributes was displayed as ldquooverriddenrdquo instead of ldquoinheritedrdquo

                        NIOS-50199 Major Unable to modify a DHCP scope that was synchronized from a Microsoft DHCP failover partner

                        NIOS-50171 Major Users could not convert a lease to a fixed address without the ldquoNetwork Discoveryrdquo permission which was not required

                        NIOS-50137 Major VLAN tagging was not functional properly on the HA interface

                        NIOS-50112 Major High CPU usage on Captive Portal caused by the ldquoomshellrdquo process

                        NIOS-50081 Major Unable to add the same IPv6 loopback address on other Grid members when the IPv6 address is already configured on the Grid Master

                        NIOS-50057 Major DHCP service interruptions occurred after an upgrade due to issues related to disabled Grid members in a MAC address filter

                        NIOS-50052 Major Addressed the following SSL 30 vulnerability CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

                        NIOS-49962 Major Unable to edit and save Upgrade Schedule

                        NIOS-49941 Major In a Multi-Grid configuration the Master Grid experienced high swap usage while processing a lot of data

                        NIOS-49935 Major Under certain circumstances exporting visible data from Grid Manager could fail for a zone

                        NIOS 701 Release Notes

                        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 15 of 21 400-0579-001 Rev A 1212015

                        NIOS-49934 Major API On rare occasions searching with return_methods could result in incorrect PAPI results

                        NIOS-49847 Major The appliance returned an error when users tried to disable GSS-TSIG and remove the keys

                        NIOS-49826 Major Could not start DNS service on the Grid Secondary for a zone that had an external Primary while moving the LAN2 IP address from one member to the other

                        NIOS-49809 Major In a network template users could not save values for an extensible attribute that was a ldquolistrdquo type

                        NIOS-49735 Major The status of a Microsoft server was ldquoConnectingrdquo even when synchronization was in progress

                        NIOS-49505 Major High disk space usage was observed after enabling ldquoCapture DNS Queriesrdquo and ldquoCapture DNS Responsesrdquo

                        NIOS-49473 Major On rare occasions the Grid Master rebooted and went offline

                        NIOS-49349 Major The infobloxlog captured bloxTools user password in plain text

                        NIOS-49339 Major Grid Manager access was denied due to a missing object in the backup file

                        NIOS-49137 Major Advanced DNS Protection An unexpected HA failover occurred due to a general protection fault

                        NIOS-48437 Major DNS latency for DNS responses from cache was higher than usual for a duration of a couple seconds

                        NIOS-48009 Major A schedule upgrade did not function properly if the HA Grid Master had not replicated the schedule to the passive node before the upgrade started

                        NIOS-47994 Major DHCP service failed to start due to invalid DHCP option spaces defined in the DHCP configuration file

                        NIOS-50571 Minor Added descriptions about VLAN tag and DSCP support for TE-1400 series appliances to the Infoblox NIOS Administrator Guide

                        NIOS-50466 Minor DNS service startup took longer than expected due to journal file fragmentation

                        NIOS-50430 Minor Redefined the description for ldquoinfoblox-deny-rpzrdquo in the Infoblox NIOS Administrator Guide

                        NIOS-50401 Minor When associating a network with a Microsoft site an error message was displayed in the background instead of inside the editor

                        NIOS-50366 Minor Updated the CSV Import Reference to include the file format for ldquoresponsepolicyipaddressrdquo objects

                        NIOS-50267 Minor Unable to perform a discovery for a Microsoft managed subnet

                        NIOS-49986 Minor Updated IP addresses used in example in the Infoblox NIOS Administrator Guide

                        NIOS-49838 Minor Could not transfer support bundle using the transfer_supportbundle command

                        NIOS-49816 Minor The Discoverer field value was truncated in the IP MAP viewer under the Discovered Data tab

                        NIOS-49787 Minor The appliance logged excessive debugging messages

                        NIOS 701 Release Notes

                        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 16 of 21 400-0579-001 Rev A 1212015

                        NIOS-48037 Minor Value for the extensible attribute ldquoSiterdquo was not displayed in the Lease Selector when

                        users tried to connect to an auto-provisioned member

                        NIOS-50399 Enhance Enhanced the ldquoConvertrdquo button to also appear in the IPAM home page

                        Severity Levels Severity Description

                        Critical Core network services are significantly impacted Major Network services are impacted but there is an available workaround Moderate Some loss of secondary services or configuration abilities Minor Minor functional or UI issue Enhance An enhancement to the product

                        KNOWN GENERAL ISSUES

                        ID Summary

                        NIOS-51323 DNS Traffic Control The appliance may return a timeout error while loading the Traffic Management tab in Grid Manager if you have configured health monitoring for a lot of DTC servers

                        NIOS-51287 Cloud Network Automation Modifying resource records through the cloud API will cause extensible attribute values to be removed

                        NIOS-51235 In a Multi-Grid configuration converting network connectivity for the Master Grid and its sub Grids to IPv6 only is not supported even though Grid Manager may allow you to do so

                        NIOS-51134 Infoblox appliances currently do not support HP passive copper cables

                        NIOS-51054 After you upgrade to NIOS 700 Infoblox recommends that you back up the configuration after you change network connectivity to a different mode (IPv4 IPv6 or IPv4 and IPv6 dual mode) Restoring an old backup by performing a forced restore may prevent some Grid members from rejoining the Grid after the restore

                        NIOS-50997 In this release the appliance does not automatically create a reverse-mapping zones for 1 for DNS servers that support IPv6

                        NIOS-50873 When you enable DNS and DHCP services for IPv6 only DDNS updates may not function properly for certain configurations Infoblox recommends that you do not enable DDNS updates in an IPv6-only Grid

                        NIOS-50859 Creating custom IPv6 NS records and pointing a zone to a particular IPv6 name server is not supported in this release

                        NIOS-50994 Cloud Network Automation When there is no tenant associated with a network or VM or if a network or VM is created by a cloud adapter but the tenant ID is not specified in the cloud API request the Name or ID column for the tenant or VM is left blank in Grid Manager which implies ldquoNArdquo or not applicable for the specified network or VM

                        NIOS 701 Release Notes

                        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 17 of 21 400-0579-001 Rev A 1212015

                        NA Reporting When there is too much data being displayed in a graph data can overlap each other and make it difficult for viewing You can expand the graph to view specific data by stretching the graph on display However you will not be able to download the expanded graph in a PDF Workaround Right-click the expanded graph and then select This Frame -gt Print Frame from the drop-down menu to print the graph

                        NIOS-49238 Network Insight Under certain circumstances deleting networks may not remove the corresponding IP helper addresses from the device configuration

                        NIOS-49123 Network Insight When scheduling a discovery or port control blackout the scheduled time and time zone will always be standard time No time adjustments are made if the selected time zone is currently in daylight savings time and no adjustments are made when the time zone switches to daylight savings time

                        NIOS-49107 Network Insight If a recurring port control blackout is scheduled and it includes the current time port control tasks will be delayed during the current blackout period However you may not be warned until the next blackout period If a recurring discovery blackout is scheduled and it includes the current time the Discover Now functionality may not be blocked until the next blackout period

                        AUGUSTA2-1606

                        Network Insight Some devices such as the Cisco 3750X may report interfaces (that are not actually functional) as available through SNMP which could cause Port Control jobs on these non-functional interfaces to fail

                        NIOS-48944 Reporting When there are disconnected data points in the reporting data for reports (such as the DNS Query Rate by Query Type report) that support the stacked area panel type the stacked area that represents the disconnected data in the PDF report may not fill up accordingly and may cause it to look like a line chart when it is actually a stacked area chart Workaround Interpret the information correctly when reading the stacked area charts that contain disconnected data points

                        NIOS-48912 Network Insight Is a device is not connected to another host through a network the appliance will not be able to detect the Voice VLAN information

                        NIOS-48897 Network Insight Alcatel Omniswitches can operate in two modesmdashWorking mode and Certified mode Alcatel OmniSwitch 6000 devices must run in Working mode to allow Port Control jobs to work on these devices

                        NIOS-48704 Reporting When you configure a search for Top Devices Denied an IP Address using Member Network View Network and CIDR as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

                        NIOS-48560 Network Insight Before joining the Network Data Consolidator to the Grid use the CLI command reset net-automation database to ensure that previously discovered device information is removed from the database

                        NIOS-48399 You cannot restore the existing deleted resource records from the Recycle Bin after you promote a Grid Master Candidate to the Grid Master

                        NIOS-48311 On the IB-4010 appliance the maximum resource records allowed in a single signing zone is 800K not 25 of the object limit as in other platforms Exceeding this limit may result in a system restart

                        NIOS-48135 bloxTools data prior to NIOS 640 cannot be restored on NIOS 611x Workaround Upgrade to NIOS 64x first to get a backup before upgrading to NIOS 611x

                        NIOS 701 Release Notes

                        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 18 of 21 400-0579-001 Rev A 1212015

                        NIOS-48030 You may not be able to log in to the bloxTools Workflow environment if you download the snapin-workflow file from the bloxTools Community site

                        NIOS-47959 Through the API and RESTful API users can add records and data without entering values for required extensible attributes Users cannot do the same through Grid Manager

                        NIOS-46356 An upgrade may fail if you clone reports and searches with duplicate names for the following reports DNS Query Rate by Server DNS Daily Query Rate by Server DNS Daily Peak Hour Query Rate by Server DHCP Device Operating System Trend DHCP Top Device Operating System and Traffic Rate

                        NIOS-46290 In some scenarios upgrading from NIOS 67x to NIOS 610x on an Infoblox-4030 appliance may require a manual restart to complete the upgrade

                        NIOS-46102 Advanced DNS Protection You may not be able to join an independent appliance to the Grid if the appliance has threat protection service enabled and only the LAN interface configured Workaround Disable threat protection service on the appliance before joining the Grid or configure the MGMT port and enable VPN on MGMT before joining the offline appliance to the Grid

                        NIOS-46051 Reporting When you configure a search for Threat Protect Event Count by Severity Trend using Member Category and Rule ID as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

                        NIOS-45906 Network Insight On rare occasions when there is incomplete inaccurate or misinterpreted data in discovered spanning tree information the appliance may not be able to determine the correct switch to which an end host is attached In this scenario the appliance may display inaccurate discovered data

                        NIOS-45904 Network Insight In Grid Manager the same end host on different VLANs may appear as duplicates that contain the same VLAN information

                        NIOS-45872 Content in the bloxHub widget on the Status Dashboard may not be displayed in certain versions of Google Chrome Mozilla FireFox and Microsoft Internet Explorer browsers due to security updates implemented by these browsers Workarounds For Chrome Click the security shield icon next to the URL and select Load unsafe script For FireFox Click the security shield icon next to the URL and select Disable Protection on This Page from the drop-down list For IE Click Show all content in the Only secure content is displayed message bar at the bottom of the page

                        NIOS-45598 Network Insight When a seed router is specified for an IP address that has already been assigned as a fixed address the IP will still be discovered even if the fixed address is excluded from discovery

                        NIOS-45233 Reporting When you use Microsoft Internet Explorer 10x and disable ldquoCompatibility Viewrdquo you may not be able to view reports in the Reporting tab Workaround In the Internet Explorer 10 browser go to Tools -gt Compatibility View to enable the feature

                        NIOS-45220 When you upgrade from NIOS 51r6-12 or earlier releases the Try Snapinstall option may not be available in the bloxTools environment after the upgrade Workaround Stop bloxTools service on the member console connect to the member through the CLI and execute the set bloxtools reset all command Once the reset process is complete restart the bloxTools service to access the Try Snapinstall option

                        NIOS 701 Release Notes

                        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 19 of 21 400-0579-001 Rev A 1212015

                        VLAN-324 If you have assigned multiple VLANs to the LAN1 or LAN2 interfaces on the appliance you may receive messages about having ldquomultiple interfaces that match the same subnetrdquo during dhcpd process startups or restarts Note that these are not error messages and no actions are required

                        NIOS-44055 If you use certain versions of Mozilla FireFox to run Grid Manager the auto-detected time zone feature may not function properly even if you have enabled it in your User Profile

                        NIOS-43957 When you upgrade from NIOS 66x or earlier releases the email address in the SOA resource record that was entered in punycode will be converted into IDN (Internationalized Domain Name) after the upgrade Workaround Convert the IDN back to punycode using the IDN converter utility through Grid Manager

                        NIOS-43569 You may not be able to view reverse-mapping zones in an internal DNS view Workaround Set the table size to 10 in User Profile log out and then log back in to the system again

                        NIOS-41136 Reporting When you use certain versions of Mozilla Firefox and Google Chrome browsers on Windows 7 or Linux you may not be able to properly print reports

                        NIOS-39922 On Trinzic 2200 series appliances it may take up to three minutes for the LOM (Light On Management) LED to stop blinking after you have disabled the LOM feature

                        NIOS-38870 When you change the member type of an appliance from Infoblox to vNIOS the appliance might display an error message indicating that all network port settings of the vNIOS member must be changed to Automatic Workaround Through the Infoblox API use InfobloxGridMember and the functions lan_port_duplex( ) and lan_port_speed ( ) to change the network port settings for the vNIOS member

                        NIOS-38579 Reporting If you have a quick filter that includes a filter criterion with report comment equals to a value that NIOS automatically translates to another value the quick filter may not function properly after an upgrade to NIOS 65 or 66 NIOS automatically translates the following ldquoIPAM Utilizationrdquo to ldquoDDI Utilizationrdquo ldquoDNS Zone Statistics per DNS Viewrdquo to ldquoDNS Statistics per DNS Viewrdquo ldquoDNS Zone Statistics per DNS Zonerdquo to ldquoDNS Statistics per Zonerdquo ldquoDNS Member QPS Trendrdquo to ldquoDNS Query Rate by Serverrdquo and ldquoDNS Queries per Second Trendrdquo to ldquoDNS Query Rate by Query Typerdquo Workaround 1 Edit the original report comment values to match the translated values For example if you have entered ldquoIPAM Utilizationrdquo in the comment field of a report change it to ldquoDDI Utilizationrdquo Workaround 2 Edit the quick filter names to match the original comment values For example if you have entered ldquoQF1rdquo as a quick filter name and ldquoIPAM Utilizationrdquo as the report comment change the quick filter name to ldquoIPAM Utilizationrdquo

                        NIOS-37415 Users cannot execute Trinzic Automation Engine (TAE) if they log out of NetMRI during an active NetMRI session

                        NIOS-33600 There is an issue with SafeNet HSMs in that configuration changes do not immediately take effect such as when adding a new member to an existing SafeNet HSM Group deleting a client from the HSM or making member changes You can perform a forced restart of services to apply the changes immediately

                        NIOS-31864 Modifying a zone from a client increments the zonersquos serial number even if the zone contents did not change This causes unnecessary AXFRs to secondary servers and if the zone is served by a Microsoft Server that is managed in read-write mode it causes extra synchronizations as well

                        NIOS 701 Release Notes

                        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 20 of 21 400-0579-001 Rev A 1212015

                        NIOS-31501 When a Microsoft server is the primary server for a zone and another Microsoft server is hosting the same zone as a stub zone and the NIOS appliance synchronizes DNS data with only one of these zones it will synchronize the zone as an authoritative or stub zone depending on which Microsoft server it synchronizes with first For more information please refer to KB article 17593

                        NIOS-25064 (45488)

                        If you configured a member DHCP server to authenticate DHCP clients with a RADIUS authentication server group and RADIUS is disabled (the server group is disabled all RADIUS servers in the group are disabled or the member DHCP server was not assigned an authentication server group) NAC filters with ldquodoes not equalrdquo rules will always match Workaround Do not disable RADIUS

                        NIOS-21512 (39917)

                        When you stop the DNS service of an independent appliance with temporary DNS and DHCP licenses Grid Manager displays the Restart Services panel regardless of which function you select

                        NIOS-21499 (38968)

                        An admin cannot display DNS views created by other admins during the same browser session To display the DNS views created by other admins you must log out and log in again

                        NIOS-19853 (31668)

                        Grid Manager does not display an error when you move a DNS view to a network view that contains a host record that has the same MAC address as a host record in the DNS view that is being moved

                        NIOS-19144 (30208)

                        Grid Manager does not sort columns correctly in the IPAM and Network list panels when the columns contain UTF-8 data

                        NIOS-18163 (27831)

                        The appliance allows users with read-only permission to A records to view DNSSEC resource records as well

                        NIOS-17636 (26233)

                        Syslog messages generated during a TFTP file transfer display the incorrect time zone

                        NIOS-17513 (26080)

                        Adding updating or deleting reverse zones could fail due to unsupported PTR records in the root zone

                        PAPIPASS-39

                        When you use Mozilla Firefox 16x 17x or Mozilla Firefox Beta 180b3 browser the hidden password in the Add Administrator Wizard of Grid Manager may disappear when you click the Password field after you have confirmed the password This is a known issue when you use Firefox browsers

                        MME-154 When a NIOS user deletes a Microsoft AD domainrsquos primary zones and subzones NIOS should display a more specific message warning users about the consequences of the operation instead of the general warning message it currently displays

                        MME-129 When a Microsoft admin creates a delegation on the Microsoft server and the delegation is synchronized to the NIOS appliance the glue A record of the delegation name server is synchronized to the appliance as a manually created record If on the NIOS appliance an admin changes the IP address on the NS record of the delegation name server two A glue records are generated one with the original address one with the new address NIOS retains the original glue A record because itrsquos marked as a manually created record and it can only be changed or deleted either manually on Grid Manager or through the API When synchronization occurs the Microsoft server correctly updates the existing glue A record and does not retain the original Note that NIOS retains the original A record only after the initial update If you update the A record again NIOS just updates the existing record without retaining the original

                        MME-23 NIOS displays an ldquoInternal Errorrdquo message when you try to apply a quick filter for a range that equals 1 when you display a range in the IPv4 Microsoft Superscopes tab

                        MME-6 If you add a hostname to the Target field of an SRV record on Grid Manager when the member synchronizes the SRV record to a Microsoft server it adds a new SRV record with the hostname instead of modifying the existing record

                        NIOS 701 Release Notes

                        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 21 of 21 400-0579-001 Rev A 1212015

                        MSSS-11 (45296)

                        When you run a discovery on a network served by Microsoft servers and Grid Manager discovers a MAC address that does not match any of the fixed addresses associated with an IP address it reports a conflict and lists the associated fixed address objects in the Related Objects table You cannot select which fixed address to resolve in the Related Objects table You can only resolve the conflict for the first address

                        VNIOS-36 (41215)

                        If a virtual NIOS member does not start up due to a license violation Grid Manager displays the status of the vNIOS member as ldquoonlinerunningrdquo even though the member is not online

                        • INTRODUCTION
                          • Supported Platforms
                            • NEW FEATURES
                              • NIOS 700
                                • CHANGES TO DEFAULT BEHAVIOR
                                  • NIOS 700
                                  • NIOS 6x Releases
                                    • CHANGES TO Infoblox API and RESTful API
                                      • RESTful API Deprecation and Backward Compatibility Policy
                                      • NIOS 70x
                                      • NIOS 6x Releases
                                        • UPGRADE GUIDELINES
                                          • Upgrading to NIOS 70x
                                            • BEFORE YOU INSTALL
                                            • ACCESSING GRID MANAGER
                                            • ADDRESSED VULNERABILITIES
                                            • RESOLVED ISSUES
                                              • Fixed in 701
                                              • Fixed in 700
                                                • KNOWN GENERAL ISSUES

                          NIOS 701 Release Notes

                          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 13 of 21 400-0579-001 Rev A 1212015

                          CERT VULNERABILITY NOTE CVE-2014-3470 Enabling anonymous ECDH cipher suites on TLS clients could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0224 A specially crafted handshake packet could force the use of weak keying material in the SSLTLS clients allowing a man-in-the-middle (MITM) attack to decrypt and modify traffic between a client and a server CERT VULNERABILITY NOTE CVE-2014-0221 Remote attackers could utilize DTLS hello message in an invalid DTLS handshake to cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0198 Enabling SSL_MODE_RELEASE_BUFFERS failed to manage buffer pointer during certain recursive calls that could cause a denial of service CERT VULNERABILITY NOTE CVE-2014-0195 Remote attackers could trigger buffer overrun attack through invalid DTLS fragments to an OpenSSL DTLS client or server resulting in a denial of service CERT VULNERABILITY NOTE CVE-2014-0591 A crafted query against an NSEC3-signed zone could cause the named process to terminate RESOLVED ISSUES The following issues were reported in previous NIOS releases and resolved in this release The resolved issues are listed by severity For descriptions of the severity levels refer to Severity Levels on page 16 Fixed in 701

                          ID Severity Summary

                          NIOS-51535 Major An IPv6 address configured before NIOS 640 was not properly preserved during an upgrade to NIOS 700 which caused an error during product initialization

                          Fixed in 700

                          ID Severity Summary

                          NIOS-50432 Critical Addressed zone journal file size issues that caused DNS service to slow down

                          NIOS-50295 Critical After a DIW import there were some missing delegations and records in the Grid data set

                          NIOS-50162 NIOS-50124

                          Critical Under certain circumstances intermittent DNS service interruptions occurred

                          ID Severity Summary

                          NIOS-51186 Major DNS failed to respond to some queries due to new limits exposed by CVE-2014-8500

                          NIOS-51051 Major DNS service interruptions occurred after changing RPZ records

                          NIOS 701 Release Notes

                          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 14 of 21 400-0579-001 Rev A 1212015

                          NIOS-50894 Major Updated the Infoblox NIOS Administrator Guide to include information about virtual TFTP root is supported only for file downloads but not for file uploads using TFTP client

                          NIOS-50784 Major Addressed the following OpenVPN vulnerability CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet

                          NIOS-50532 Major Addressed the following vulnerabilities CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation

                          NIOS-50617 NIOS-49810

                          Major Grid Manager inappropriately marked IPv6 leases as having invalid MAC addresses

                          NIOS-50575 Major NIOS did not show the root domain for Microsoft servers belonging to two Domains in the same Forest

                          NIOS-50567 Major DIW failed to handle common CNAME records in different DNS views

                          NIOS-50453 Major Added information about HA Grid Master providing NTP service through VIP to the Infoblox NIOS Administrator Guide

                          NIOS-50402 Major Under certain circumstances NIOS returned option 43 in the response when users applied a non-global IPv4 option filter to a DHCP range

                          NIOS-50250 Major Unable to remove a Grid from the Master Grid

                          NIOS-50208 Major On some occasions the inheritance state for inherited extensible attributes was displayed as ldquooverriddenrdquo instead of ldquoinheritedrdquo

                          NIOS-50199 Major Unable to modify a DHCP scope that was synchronized from a Microsoft DHCP failover partner

                          NIOS-50171 Major Users could not convert a lease to a fixed address without the ldquoNetwork Discoveryrdquo permission which was not required

                          NIOS-50137 Major VLAN tagging was not functional properly on the HA interface

                          NIOS-50112 Major High CPU usage on Captive Portal caused by the ldquoomshellrdquo process

                          NIOS-50081 Major Unable to add the same IPv6 loopback address on other Grid members when the IPv6 address is already configured on the Grid Master

                          NIOS-50057 Major DHCP service interruptions occurred after an upgrade due to issues related to disabled Grid members in a MAC address filter

                          NIOS-50052 Major Addressed the following SSL 30 vulnerability CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

                          NIOS-49962 Major Unable to edit and save Upgrade Schedule

                          NIOS-49941 Major In a Multi-Grid configuration the Master Grid experienced high swap usage while processing a lot of data

                          NIOS-49935 Major Under certain circumstances exporting visible data from Grid Manager could fail for a zone

                          NIOS 701 Release Notes

                          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 15 of 21 400-0579-001 Rev A 1212015

                          NIOS-49934 Major API On rare occasions searching with return_methods could result in incorrect PAPI results

                          NIOS-49847 Major The appliance returned an error when users tried to disable GSS-TSIG and remove the keys

                          NIOS-49826 Major Could not start DNS service on the Grid Secondary for a zone that had an external Primary while moving the LAN2 IP address from one member to the other

                          NIOS-49809 Major In a network template users could not save values for an extensible attribute that was a ldquolistrdquo type

                          NIOS-49735 Major The status of a Microsoft server was ldquoConnectingrdquo even when synchronization was in progress

                          NIOS-49505 Major High disk space usage was observed after enabling ldquoCapture DNS Queriesrdquo and ldquoCapture DNS Responsesrdquo

                          NIOS-49473 Major On rare occasions the Grid Master rebooted and went offline

                          NIOS-49349 Major The infobloxlog captured bloxTools user password in plain text

                          NIOS-49339 Major Grid Manager access was denied due to a missing object in the backup file

                          NIOS-49137 Major Advanced DNS Protection An unexpected HA failover occurred due to a general protection fault

                          NIOS-48437 Major DNS latency for DNS responses from cache was higher than usual for a duration of a couple seconds

                          NIOS-48009 Major A schedule upgrade did not function properly if the HA Grid Master had not replicated the schedule to the passive node before the upgrade started

                          NIOS-47994 Major DHCP service failed to start due to invalid DHCP option spaces defined in the DHCP configuration file

                          NIOS-50571 Minor Added descriptions about VLAN tag and DSCP support for TE-1400 series appliances to the Infoblox NIOS Administrator Guide

                          NIOS-50466 Minor DNS service startup took longer than expected due to journal file fragmentation

                          NIOS-50430 Minor Redefined the description for ldquoinfoblox-deny-rpzrdquo in the Infoblox NIOS Administrator Guide

                          NIOS-50401 Minor When associating a network with a Microsoft site an error message was displayed in the background instead of inside the editor

                          NIOS-50366 Minor Updated the CSV Import Reference to include the file format for ldquoresponsepolicyipaddressrdquo objects

                          NIOS-50267 Minor Unable to perform a discovery for a Microsoft managed subnet

                          NIOS-49986 Minor Updated IP addresses used in example in the Infoblox NIOS Administrator Guide

                          NIOS-49838 Minor Could not transfer support bundle using the transfer_supportbundle command

                          NIOS-49816 Minor The Discoverer field value was truncated in the IP MAP viewer under the Discovered Data tab

                          NIOS-49787 Minor The appliance logged excessive debugging messages

                          NIOS 701 Release Notes

                          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 16 of 21 400-0579-001 Rev A 1212015

                          NIOS-48037 Minor Value for the extensible attribute ldquoSiterdquo was not displayed in the Lease Selector when

                          users tried to connect to an auto-provisioned member

                          NIOS-50399 Enhance Enhanced the ldquoConvertrdquo button to also appear in the IPAM home page

                          Severity Levels Severity Description

                          Critical Core network services are significantly impacted Major Network services are impacted but there is an available workaround Moderate Some loss of secondary services or configuration abilities Minor Minor functional or UI issue Enhance An enhancement to the product

                          KNOWN GENERAL ISSUES

                          ID Summary

                          NIOS-51323 DNS Traffic Control The appliance may return a timeout error while loading the Traffic Management tab in Grid Manager if you have configured health monitoring for a lot of DTC servers

                          NIOS-51287 Cloud Network Automation Modifying resource records through the cloud API will cause extensible attribute values to be removed

                          NIOS-51235 In a Multi-Grid configuration converting network connectivity for the Master Grid and its sub Grids to IPv6 only is not supported even though Grid Manager may allow you to do so

                          NIOS-51134 Infoblox appliances currently do not support HP passive copper cables

                          NIOS-51054 After you upgrade to NIOS 700 Infoblox recommends that you back up the configuration after you change network connectivity to a different mode (IPv4 IPv6 or IPv4 and IPv6 dual mode) Restoring an old backup by performing a forced restore may prevent some Grid members from rejoining the Grid after the restore

                          NIOS-50997 In this release the appliance does not automatically create a reverse-mapping zones for 1 for DNS servers that support IPv6

                          NIOS-50873 When you enable DNS and DHCP services for IPv6 only DDNS updates may not function properly for certain configurations Infoblox recommends that you do not enable DDNS updates in an IPv6-only Grid

                          NIOS-50859 Creating custom IPv6 NS records and pointing a zone to a particular IPv6 name server is not supported in this release

                          NIOS-50994 Cloud Network Automation When there is no tenant associated with a network or VM or if a network or VM is created by a cloud adapter but the tenant ID is not specified in the cloud API request the Name or ID column for the tenant or VM is left blank in Grid Manager which implies ldquoNArdquo or not applicable for the specified network or VM

                          NIOS 701 Release Notes

                          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 17 of 21 400-0579-001 Rev A 1212015

                          NA Reporting When there is too much data being displayed in a graph data can overlap each other and make it difficult for viewing You can expand the graph to view specific data by stretching the graph on display However you will not be able to download the expanded graph in a PDF Workaround Right-click the expanded graph and then select This Frame -gt Print Frame from the drop-down menu to print the graph

                          NIOS-49238 Network Insight Under certain circumstances deleting networks may not remove the corresponding IP helper addresses from the device configuration

                          NIOS-49123 Network Insight When scheduling a discovery or port control blackout the scheduled time and time zone will always be standard time No time adjustments are made if the selected time zone is currently in daylight savings time and no adjustments are made when the time zone switches to daylight savings time

                          NIOS-49107 Network Insight If a recurring port control blackout is scheduled and it includes the current time port control tasks will be delayed during the current blackout period However you may not be warned until the next blackout period If a recurring discovery blackout is scheduled and it includes the current time the Discover Now functionality may not be blocked until the next blackout period

                          AUGUSTA2-1606

                          Network Insight Some devices such as the Cisco 3750X may report interfaces (that are not actually functional) as available through SNMP which could cause Port Control jobs on these non-functional interfaces to fail

                          NIOS-48944 Reporting When there are disconnected data points in the reporting data for reports (such as the DNS Query Rate by Query Type report) that support the stacked area panel type the stacked area that represents the disconnected data in the PDF report may not fill up accordingly and may cause it to look like a line chart when it is actually a stacked area chart Workaround Interpret the information correctly when reading the stacked area charts that contain disconnected data points

                          NIOS-48912 Network Insight Is a device is not connected to another host through a network the appliance will not be able to detect the Voice VLAN information

                          NIOS-48897 Network Insight Alcatel Omniswitches can operate in two modesmdashWorking mode and Certified mode Alcatel OmniSwitch 6000 devices must run in Working mode to allow Port Control jobs to work on these devices

                          NIOS-48704 Reporting When you configure a search for Top Devices Denied an IP Address using Member Network View Network and CIDR as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

                          NIOS-48560 Network Insight Before joining the Network Data Consolidator to the Grid use the CLI command reset net-automation database to ensure that previously discovered device information is removed from the database

                          NIOS-48399 You cannot restore the existing deleted resource records from the Recycle Bin after you promote a Grid Master Candidate to the Grid Master

                          NIOS-48311 On the IB-4010 appliance the maximum resource records allowed in a single signing zone is 800K not 25 of the object limit as in other platforms Exceeding this limit may result in a system restart

                          NIOS-48135 bloxTools data prior to NIOS 640 cannot be restored on NIOS 611x Workaround Upgrade to NIOS 64x first to get a backup before upgrading to NIOS 611x

                          NIOS 701 Release Notes

                          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 18 of 21 400-0579-001 Rev A 1212015

                          NIOS-48030 You may not be able to log in to the bloxTools Workflow environment if you download the snapin-workflow file from the bloxTools Community site

                          NIOS-47959 Through the API and RESTful API users can add records and data without entering values for required extensible attributes Users cannot do the same through Grid Manager

                          NIOS-46356 An upgrade may fail if you clone reports and searches with duplicate names for the following reports DNS Query Rate by Server DNS Daily Query Rate by Server DNS Daily Peak Hour Query Rate by Server DHCP Device Operating System Trend DHCP Top Device Operating System and Traffic Rate

                          NIOS-46290 In some scenarios upgrading from NIOS 67x to NIOS 610x on an Infoblox-4030 appliance may require a manual restart to complete the upgrade

                          NIOS-46102 Advanced DNS Protection You may not be able to join an independent appliance to the Grid if the appliance has threat protection service enabled and only the LAN interface configured Workaround Disable threat protection service on the appliance before joining the Grid or configure the MGMT port and enable VPN on MGMT before joining the offline appliance to the Grid

                          NIOS-46051 Reporting When you configure a search for Threat Protect Event Count by Severity Trend using Member Category and Rule ID as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

                          NIOS-45906 Network Insight On rare occasions when there is incomplete inaccurate or misinterpreted data in discovered spanning tree information the appliance may not be able to determine the correct switch to which an end host is attached In this scenario the appliance may display inaccurate discovered data

                          NIOS-45904 Network Insight In Grid Manager the same end host on different VLANs may appear as duplicates that contain the same VLAN information

                          NIOS-45872 Content in the bloxHub widget on the Status Dashboard may not be displayed in certain versions of Google Chrome Mozilla FireFox and Microsoft Internet Explorer browsers due to security updates implemented by these browsers Workarounds For Chrome Click the security shield icon next to the URL and select Load unsafe script For FireFox Click the security shield icon next to the URL and select Disable Protection on This Page from the drop-down list For IE Click Show all content in the Only secure content is displayed message bar at the bottom of the page

                          NIOS-45598 Network Insight When a seed router is specified for an IP address that has already been assigned as a fixed address the IP will still be discovered even if the fixed address is excluded from discovery

                          NIOS-45233 Reporting When you use Microsoft Internet Explorer 10x and disable ldquoCompatibility Viewrdquo you may not be able to view reports in the Reporting tab Workaround In the Internet Explorer 10 browser go to Tools -gt Compatibility View to enable the feature

                          NIOS-45220 When you upgrade from NIOS 51r6-12 or earlier releases the Try Snapinstall option may not be available in the bloxTools environment after the upgrade Workaround Stop bloxTools service on the member console connect to the member through the CLI and execute the set bloxtools reset all command Once the reset process is complete restart the bloxTools service to access the Try Snapinstall option

                          NIOS 701 Release Notes

                          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 19 of 21 400-0579-001 Rev A 1212015

                          VLAN-324 If you have assigned multiple VLANs to the LAN1 or LAN2 interfaces on the appliance you may receive messages about having ldquomultiple interfaces that match the same subnetrdquo during dhcpd process startups or restarts Note that these are not error messages and no actions are required

                          NIOS-44055 If you use certain versions of Mozilla FireFox to run Grid Manager the auto-detected time zone feature may not function properly even if you have enabled it in your User Profile

                          NIOS-43957 When you upgrade from NIOS 66x or earlier releases the email address in the SOA resource record that was entered in punycode will be converted into IDN (Internationalized Domain Name) after the upgrade Workaround Convert the IDN back to punycode using the IDN converter utility through Grid Manager

                          NIOS-43569 You may not be able to view reverse-mapping zones in an internal DNS view Workaround Set the table size to 10 in User Profile log out and then log back in to the system again

                          NIOS-41136 Reporting When you use certain versions of Mozilla Firefox and Google Chrome browsers on Windows 7 or Linux you may not be able to properly print reports

                          NIOS-39922 On Trinzic 2200 series appliances it may take up to three minutes for the LOM (Light On Management) LED to stop blinking after you have disabled the LOM feature

                          NIOS-38870 When you change the member type of an appliance from Infoblox to vNIOS the appliance might display an error message indicating that all network port settings of the vNIOS member must be changed to Automatic Workaround Through the Infoblox API use InfobloxGridMember and the functions lan_port_duplex( ) and lan_port_speed ( ) to change the network port settings for the vNIOS member

                          NIOS-38579 Reporting If you have a quick filter that includes a filter criterion with report comment equals to a value that NIOS automatically translates to another value the quick filter may not function properly after an upgrade to NIOS 65 or 66 NIOS automatically translates the following ldquoIPAM Utilizationrdquo to ldquoDDI Utilizationrdquo ldquoDNS Zone Statistics per DNS Viewrdquo to ldquoDNS Statistics per DNS Viewrdquo ldquoDNS Zone Statistics per DNS Zonerdquo to ldquoDNS Statistics per Zonerdquo ldquoDNS Member QPS Trendrdquo to ldquoDNS Query Rate by Serverrdquo and ldquoDNS Queries per Second Trendrdquo to ldquoDNS Query Rate by Query Typerdquo Workaround 1 Edit the original report comment values to match the translated values For example if you have entered ldquoIPAM Utilizationrdquo in the comment field of a report change it to ldquoDDI Utilizationrdquo Workaround 2 Edit the quick filter names to match the original comment values For example if you have entered ldquoQF1rdquo as a quick filter name and ldquoIPAM Utilizationrdquo as the report comment change the quick filter name to ldquoIPAM Utilizationrdquo

                          NIOS-37415 Users cannot execute Trinzic Automation Engine (TAE) if they log out of NetMRI during an active NetMRI session

                          NIOS-33600 There is an issue with SafeNet HSMs in that configuration changes do not immediately take effect such as when adding a new member to an existing SafeNet HSM Group deleting a client from the HSM or making member changes You can perform a forced restart of services to apply the changes immediately

                          NIOS-31864 Modifying a zone from a client increments the zonersquos serial number even if the zone contents did not change This causes unnecessary AXFRs to secondary servers and if the zone is served by a Microsoft Server that is managed in read-write mode it causes extra synchronizations as well

                          NIOS 701 Release Notes

                          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 20 of 21 400-0579-001 Rev A 1212015

                          NIOS-31501 When a Microsoft server is the primary server for a zone and another Microsoft server is hosting the same zone as a stub zone and the NIOS appliance synchronizes DNS data with only one of these zones it will synchronize the zone as an authoritative or stub zone depending on which Microsoft server it synchronizes with first For more information please refer to KB article 17593

                          NIOS-25064 (45488)

                          If you configured a member DHCP server to authenticate DHCP clients with a RADIUS authentication server group and RADIUS is disabled (the server group is disabled all RADIUS servers in the group are disabled or the member DHCP server was not assigned an authentication server group) NAC filters with ldquodoes not equalrdquo rules will always match Workaround Do not disable RADIUS

                          NIOS-21512 (39917)

                          When you stop the DNS service of an independent appliance with temporary DNS and DHCP licenses Grid Manager displays the Restart Services panel regardless of which function you select

                          NIOS-21499 (38968)

                          An admin cannot display DNS views created by other admins during the same browser session To display the DNS views created by other admins you must log out and log in again

                          NIOS-19853 (31668)

                          Grid Manager does not display an error when you move a DNS view to a network view that contains a host record that has the same MAC address as a host record in the DNS view that is being moved

                          NIOS-19144 (30208)

                          Grid Manager does not sort columns correctly in the IPAM and Network list panels when the columns contain UTF-8 data

                          NIOS-18163 (27831)

                          The appliance allows users with read-only permission to A records to view DNSSEC resource records as well

                          NIOS-17636 (26233)

                          Syslog messages generated during a TFTP file transfer display the incorrect time zone

                          NIOS-17513 (26080)

                          Adding updating or deleting reverse zones could fail due to unsupported PTR records in the root zone

                          PAPIPASS-39

                          When you use Mozilla Firefox 16x 17x or Mozilla Firefox Beta 180b3 browser the hidden password in the Add Administrator Wizard of Grid Manager may disappear when you click the Password field after you have confirmed the password This is a known issue when you use Firefox browsers

                          MME-154 When a NIOS user deletes a Microsoft AD domainrsquos primary zones and subzones NIOS should display a more specific message warning users about the consequences of the operation instead of the general warning message it currently displays

                          MME-129 When a Microsoft admin creates a delegation on the Microsoft server and the delegation is synchronized to the NIOS appliance the glue A record of the delegation name server is synchronized to the appliance as a manually created record If on the NIOS appliance an admin changes the IP address on the NS record of the delegation name server two A glue records are generated one with the original address one with the new address NIOS retains the original glue A record because itrsquos marked as a manually created record and it can only be changed or deleted either manually on Grid Manager or through the API When synchronization occurs the Microsoft server correctly updates the existing glue A record and does not retain the original Note that NIOS retains the original A record only after the initial update If you update the A record again NIOS just updates the existing record without retaining the original

                          MME-23 NIOS displays an ldquoInternal Errorrdquo message when you try to apply a quick filter for a range that equals 1 when you display a range in the IPv4 Microsoft Superscopes tab

                          MME-6 If you add a hostname to the Target field of an SRV record on Grid Manager when the member synchronizes the SRV record to a Microsoft server it adds a new SRV record with the hostname instead of modifying the existing record

                          NIOS 701 Release Notes

                          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 21 of 21 400-0579-001 Rev A 1212015

                          MSSS-11 (45296)

                          When you run a discovery on a network served by Microsoft servers and Grid Manager discovers a MAC address that does not match any of the fixed addresses associated with an IP address it reports a conflict and lists the associated fixed address objects in the Related Objects table You cannot select which fixed address to resolve in the Related Objects table You can only resolve the conflict for the first address

                          VNIOS-36 (41215)

                          If a virtual NIOS member does not start up due to a license violation Grid Manager displays the status of the vNIOS member as ldquoonlinerunningrdquo even though the member is not online

                          • INTRODUCTION
                            • Supported Platforms
                              • NEW FEATURES
                                • NIOS 700
                                  • CHANGES TO DEFAULT BEHAVIOR
                                    • NIOS 700
                                    • NIOS 6x Releases
                                      • CHANGES TO Infoblox API and RESTful API
                                        • RESTful API Deprecation and Backward Compatibility Policy
                                        • NIOS 70x
                                        • NIOS 6x Releases
                                          • UPGRADE GUIDELINES
                                            • Upgrading to NIOS 70x
                                              • BEFORE YOU INSTALL
                                              • ACCESSING GRID MANAGER
                                              • ADDRESSED VULNERABILITIES
                                              • RESOLVED ISSUES
                                                • Fixed in 701
                                                • Fixed in 700
                                                  • KNOWN GENERAL ISSUES

                            NIOS 701 Release Notes

                            copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 14 of 21 400-0579-001 Rev A 1212015

                            NIOS-50894 Major Updated the Infoblox NIOS Administrator Guide to include information about virtual TFTP root is supported only for file downloads but not for file uploads using TFTP client

                            NIOS-50784 Major Addressed the following OpenVPN vulnerability CVE-2014-8104 The OpenVPN community issued a patch to address a vulnerability in which remote authenticated users could cause a critical denial of service on Open VPN servers through a small control channel packet

                            NIOS-50532 Major Addressed the following vulnerabilities CVE-2014-8500 Failure to place limits on delegation chaining could allow an attacker to crash named or cause memory exhaustion by causing the name server to issue unlimited queries in an attempt to follow the delegation

                            NIOS-50617 NIOS-49810

                            Major Grid Manager inappropriately marked IPv6 leases as having invalid MAC addresses

                            NIOS-50575 Major NIOS did not show the root domain for Microsoft servers belonging to two Domains in the same Forest

                            NIOS-50567 Major DIW failed to handle common CNAME records in different DNS views

                            NIOS-50453 Major Added information about HA Grid Master providing NTP service through VIP to the Infoblox NIOS Administrator Guide

                            NIOS-50402 Major Under certain circumstances NIOS returned option 43 in the response when users applied a non-global IPv4 option filter to a DHCP range

                            NIOS-50250 Major Unable to remove a Grid from the Master Grid

                            NIOS-50208 Major On some occasions the inheritance state for inherited extensible attributes was displayed as ldquooverriddenrdquo instead of ldquoinheritedrdquo

                            NIOS-50199 Major Unable to modify a DHCP scope that was synchronized from a Microsoft DHCP failover partner

                            NIOS-50171 Major Users could not convert a lease to a fixed address without the ldquoNetwork Discoveryrdquo permission which was not required

                            NIOS-50137 Major VLAN tagging was not functional properly on the HA interface

                            NIOS-50112 Major High CPU usage on Captive Portal caused by the ldquoomshellrdquo process

                            NIOS-50081 Major Unable to add the same IPv6 loopback address on other Grid members when the IPv6 address is already configured on the Grid Master

                            NIOS-50057 Major DHCP service interruptions occurred after an upgrade due to issues related to disabled Grid members in a MAC address filter

                            NIOS-50052 Major Addressed the following SSL 30 vulnerability CVE-2014-3567 A denial of service vulnerability that is related to session tickets memory leaks

                            NIOS-49962 Major Unable to edit and save Upgrade Schedule

                            NIOS-49941 Major In a Multi-Grid configuration the Master Grid experienced high swap usage while processing a lot of data

                            NIOS-49935 Major Under certain circumstances exporting visible data from Grid Manager could fail for a zone

                            NIOS 701 Release Notes

                            copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 15 of 21 400-0579-001 Rev A 1212015

                            NIOS-49934 Major API On rare occasions searching with return_methods could result in incorrect PAPI results

                            NIOS-49847 Major The appliance returned an error when users tried to disable GSS-TSIG and remove the keys

                            NIOS-49826 Major Could not start DNS service on the Grid Secondary for a zone that had an external Primary while moving the LAN2 IP address from one member to the other

                            NIOS-49809 Major In a network template users could not save values for an extensible attribute that was a ldquolistrdquo type

                            NIOS-49735 Major The status of a Microsoft server was ldquoConnectingrdquo even when synchronization was in progress

                            NIOS-49505 Major High disk space usage was observed after enabling ldquoCapture DNS Queriesrdquo and ldquoCapture DNS Responsesrdquo

                            NIOS-49473 Major On rare occasions the Grid Master rebooted and went offline

                            NIOS-49349 Major The infobloxlog captured bloxTools user password in plain text

                            NIOS-49339 Major Grid Manager access was denied due to a missing object in the backup file

                            NIOS-49137 Major Advanced DNS Protection An unexpected HA failover occurred due to a general protection fault

                            NIOS-48437 Major DNS latency for DNS responses from cache was higher than usual for a duration of a couple seconds

                            NIOS-48009 Major A schedule upgrade did not function properly if the HA Grid Master had not replicated the schedule to the passive node before the upgrade started

                            NIOS-47994 Major DHCP service failed to start due to invalid DHCP option spaces defined in the DHCP configuration file

                            NIOS-50571 Minor Added descriptions about VLAN tag and DSCP support for TE-1400 series appliances to the Infoblox NIOS Administrator Guide

                            NIOS-50466 Minor DNS service startup took longer than expected due to journal file fragmentation

                            NIOS-50430 Minor Redefined the description for ldquoinfoblox-deny-rpzrdquo in the Infoblox NIOS Administrator Guide

                            NIOS-50401 Minor When associating a network with a Microsoft site an error message was displayed in the background instead of inside the editor

                            NIOS-50366 Minor Updated the CSV Import Reference to include the file format for ldquoresponsepolicyipaddressrdquo objects

                            NIOS-50267 Minor Unable to perform a discovery for a Microsoft managed subnet

                            NIOS-49986 Minor Updated IP addresses used in example in the Infoblox NIOS Administrator Guide

                            NIOS-49838 Minor Could not transfer support bundle using the transfer_supportbundle command

                            NIOS-49816 Minor The Discoverer field value was truncated in the IP MAP viewer under the Discovered Data tab

                            NIOS-49787 Minor The appliance logged excessive debugging messages

                            NIOS 701 Release Notes

                            copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 16 of 21 400-0579-001 Rev A 1212015

                            NIOS-48037 Minor Value for the extensible attribute ldquoSiterdquo was not displayed in the Lease Selector when

                            users tried to connect to an auto-provisioned member

                            NIOS-50399 Enhance Enhanced the ldquoConvertrdquo button to also appear in the IPAM home page

                            Severity Levels Severity Description

                            Critical Core network services are significantly impacted Major Network services are impacted but there is an available workaround Moderate Some loss of secondary services or configuration abilities Minor Minor functional or UI issue Enhance An enhancement to the product

                            KNOWN GENERAL ISSUES

                            ID Summary

                            NIOS-51323 DNS Traffic Control The appliance may return a timeout error while loading the Traffic Management tab in Grid Manager if you have configured health monitoring for a lot of DTC servers

                            NIOS-51287 Cloud Network Automation Modifying resource records through the cloud API will cause extensible attribute values to be removed

                            NIOS-51235 In a Multi-Grid configuration converting network connectivity for the Master Grid and its sub Grids to IPv6 only is not supported even though Grid Manager may allow you to do so

                            NIOS-51134 Infoblox appliances currently do not support HP passive copper cables

                            NIOS-51054 After you upgrade to NIOS 700 Infoblox recommends that you back up the configuration after you change network connectivity to a different mode (IPv4 IPv6 or IPv4 and IPv6 dual mode) Restoring an old backup by performing a forced restore may prevent some Grid members from rejoining the Grid after the restore

                            NIOS-50997 In this release the appliance does not automatically create a reverse-mapping zones for 1 for DNS servers that support IPv6

                            NIOS-50873 When you enable DNS and DHCP services for IPv6 only DDNS updates may not function properly for certain configurations Infoblox recommends that you do not enable DDNS updates in an IPv6-only Grid

                            NIOS-50859 Creating custom IPv6 NS records and pointing a zone to a particular IPv6 name server is not supported in this release

                            NIOS-50994 Cloud Network Automation When there is no tenant associated with a network or VM or if a network or VM is created by a cloud adapter but the tenant ID is not specified in the cloud API request the Name or ID column for the tenant or VM is left blank in Grid Manager which implies ldquoNArdquo or not applicable for the specified network or VM

                            NIOS 701 Release Notes

                            copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 17 of 21 400-0579-001 Rev A 1212015

                            NA Reporting When there is too much data being displayed in a graph data can overlap each other and make it difficult for viewing You can expand the graph to view specific data by stretching the graph on display However you will not be able to download the expanded graph in a PDF Workaround Right-click the expanded graph and then select This Frame -gt Print Frame from the drop-down menu to print the graph

                            NIOS-49238 Network Insight Under certain circumstances deleting networks may not remove the corresponding IP helper addresses from the device configuration

                            NIOS-49123 Network Insight When scheduling a discovery or port control blackout the scheduled time and time zone will always be standard time No time adjustments are made if the selected time zone is currently in daylight savings time and no adjustments are made when the time zone switches to daylight savings time

                            NIOS-49107 Network Insight If a recurring port control blackout is scheduled and it includes the current time port control tasks will be delayed during the current blackout period However you may not be warned until the next blackout period If a recurring discovery blackout is scheduled and it includes the current time the Discover Now functionality may not be blocked until the next blackout period

                            AUGUSTA2-1606

                            Network Insight Some devices such as the Cisco 3750X may report interfaces (that are not actually functional) as available through SNMP which could cause Port Control jobs on these non-functional interfaces to fail

                            NIOS-48944 Reporting When there are disconnected data points in the reporting data for reports (such as the DNS Query Rate by Query Type report) that support the stacked area panel type the stacked area that represents the disconnected data in the PDF report may not fill up accordingly and may cause it to look like a line chart when it is actually a stacked area chart Workaround Interpret the information correctly when reading the stacked area charts that contain disconnected data points

                            NIOS-48912 Network Insight Is a device is not connected to another host through a network the appliance will not be able to detect the Voice VLAN information

                            NIOS-48897 Network Insight Alcatel Omniswitches can operate in two modesmdashWorking mode and Certified mode Alcatel OmniSwitch 6000 devices must run in Working mode to allow Port Control jobs to work on these devices

                            NIOS-48704 Reporting When you configure a search for Top Devices Denied an IP Address using Member Network View Network and CIDR as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

                            NIOS-48560 Network Insight Before joining the Network Data Consolidator to the Grid use the CLI command reset net-automation database to ensure that previously discovered device information is removed from the database

                            NIOS-48399 You cannot restore the existing deleted resource records from the Recycle Bin after you promote a Grid Master Candidate to the Grid Master

                            NIOS-48311 On the IB-4010 appliance the maximum resource records allowed in a single signing zone is 800K not 25 of the object limit as in other platforms Exceeding this limit may result in a system restart

                            NIOS-48135 bloxTools data prior to NIOS 640 cannot be restored on NIOS 611x Workaround Upgrade to NIOS 64x first to get a backup before upgrading to NIOS 611x

                            NIOS 701 Release Notes

                            copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 18 of 21 400-0579-001 Rev A 1212015

                            NIOS-48030 You may not be able to log in to the bloxTools Workflow environment if you download the snapin-workflow file from the bloxTools Community site

                            NIOS-47959 Through the API and RESTful API users can add records and data without entering values for required extensible attributes Users cannot do the same through Grid Manager

                            NIOS-46356 An upgrade may fail if you clone reports and searches with duplicate names for the following reports DNS Query Rate by Server DNS Daily Query Rate by Server DNS Daily Peak Hour Query Rate by Server DHCP Device Operating System Trend DHCP Top Device Operating System and Traffic Rate

                            NIOS-46290 In some scenarios upgrading from NIOS 67x to NIOS 610x on an Infoblox-4030 appliance may require a manual restart to complete the upgrade

                            NIOS-46102 Advanced DNS Protection You may not be able to join an independent appliance to the Grid if the appliance has threat protection service enabled and only the LAN interface configured Workaround Disable threat protection service on the appliance before joining the Grid or configure the MGMT port and enable VPN on MGMT before joining the offline appliance to the Grid

                            NIOS-46051 Reporting When you configure a search for Threat Protect Event Count by Severity Trend using Member Category and Rule ID as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

                            NIOS-45906 Network Insight On rare occasions when there is incomplete inaccurate or misinterpreted data in discovered spanning tree information the appliance may not be able to determine the correct switch to which an end host is attached In this scenario the appliance may display inaccurate discovered data

                            NIOS-45904 Network Insight In Grid Manager the same end host on different VLANs may appear as duplicates that contain the same VLAN information

                            NIOS-45872 Content in the bloxHub widget on the Status Dashboard may not be displayed in certain versions of Google Chrome Mozilla FireFox and Microsoft Internet Explorer browsers due to security updates implemented by these browsers Workarounds For Chrome Click the security shield icon next to the URL and select Load unsafe script For FireFox Click the security shield icon next to the URL and select Disable Protection on This Page from the drop-down list For IE Click Show all content in the Only secure content is displayed message bar at the bottom of the page

                            NIOS-45598 Network Insight When a seed router is specified for an IP address that has already been assigned as a fixed address the IP will still be discovered even if the fixed address is excluded from discovery

                            NIOS-45233 Reporting When you use Microsoft Internet Explorer 10x and disable ldquoCompatibility Viewrdquo you may not be able to view reports in the Reporting tab Workaround In the Internet Explorer 10 browser go to Tools -gt Compatibility View to enable the feature

                            NIOS-45220 When you upgrade from NIOS 51r6-12 or earlier releases the Try Snapinstall option may not be available in the bloxTools environment after the upgrade Workaround Stop bloxTools service on the member console connect to the member through the CLI and execute the set bloxtools reset all command Once the reset process is complete restart the bloxTools service to access the Try Snapinstall option

                            NIOS 701 Release Notes

                            copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 19 of 21 400-0579-001 Rev A 1212015

                            VLAN-324 If you have assigned multiple VLANs to the LAN1 or LAN2 interfaces on the appliance you may receive messages about having ldquomultiple interfaces that match the same subnetrdquo during dhcpd process startups or restarts Note that these are not error messages and no actions are required

                            NIOS-44055 If you use certain versions of Mozilla FireFox to run Grid Manager the auto-detected time zone feature may not function properly even if you have enabled it in your User Profile

                            NIOS-43957 When you upgrade from NIOS 66x or earlier releases the email address in the SOA resource record that was entered in punycode will be converted into IDN (Internationalized Domain Name) after the upgrade Workaround Convert the IDN back to punycode using the IDN converter utility through Grid Manager

                            NIOS-43569 You may not be able to view reverse-mapping zones in an internal DNS view Workaround Set the table size to 10 in User Profile log out and then log back in to the system again

                            NIOS-41136 Reporting When you use certain versions of Mozilla Firefox and Google Chrome browsers on Windows 7 or Linux you may not be able to properly print reports

                            NIOS-39922 On Trinzic 2200 series appliances it may take up to three minutes for the LOM (Light On Management) LED to stop blinking after you have disabled the LOM feature

                            NIOS-38870 When you change the member type of an appliance from Infoblox to vNIOS the appliance might display an error message indicating that all network port settings of the vNIOS member must be changed to Automatic Workaround Through the Infoblox API use InfobloxGridMember and the functions lan_port_duplex( ) and lan_port_speed ( ) to change the network port settings for the vNIOS member

                            NIOS-38579 Reporting If you have a quick filter that includes a filter criterion with report comment equals to a value that NIOS automatically translates to another value the quick filter may not function properly after an upgrade to NIOS 65 or 66 NIOS automatically translates the following ldquoIPAM Utilizationrdquo to ldquoDDI Utilizationrdquo ldquoDNS Zone Statistics per DNS Viewrdquo to ldquoDNS Statistics per DNS Viewrdquo ldquoDNS Zone Statistics per DNS Zonerdquo to ldquoDNS Statistics per Zonerdquo ldquoDNS Member QPS Trendrdquo to ldquoDNS Query Rate by Serverrdquo and ldquoDNS Queries per Second Trendrdquo to ldquoDNS Query Rate by Query Typerdquo Workaround 1 Edit the original report comment values to match the translated values For example if you have entered ldquoIPAM Utilizationrdquo in the comment field of a report change it to ldquoDDI Utilizationrdquo Workaround 2 Edit the quick filter names to match the original comment values For example if you have entered ldquoQF1rdquo as a quick filter name and ldquoIPAM Utilizationrdquo as the report comment change the quick filter name to ldquoIPAM Utilizationrdquo

                            NIOS-37415 Users cannot execute Trinzic Automation Engine (TAE) if they log out of NetMRI during an active NetMRI session

                            NIOS-33600 There is an issue with SafeNet HSMs in that configuration changes do not immediately take effect such as when adding a new member to an existing SafeNet HSM Group deleting a client from the HSM or making member changes You can perform a forced restart of services to apply the changes immediately

                            NIOS-31864 Modifying a zone from a client increments the zonersquos serial number even if the zone contents did not change This causes unnecessary AXFRs to secondary servers and if the zone is served by a Microsoft Server that is managed in read-write mode it causes extra synchronizations as well

                            NIOS 701 Release Notes

                            copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 20 of 21 400-0579-001 Rev A 1212015

                            NIOS-31501 When a Microsoft server is the primary server for a zone and another Microsoft server is hosting the same zone as a stub zone and the NIOS appliance synchronizes DNS data with only one of these zones it will synchronize the zone as an authoritative or stub zone depending on which Microsoft server it synchronizes with first For more information please refer to KB article 17593

                            NIOS-25064 (45488)

                            If you configured a member DHCP server to authenticate DHCP clients with a RADIUS authentication server group and RADIUS is disabled (the server group is disabled all RADIUS servers in the group are disabled or the member DHCP server was not assigned an authentication server group) NAC filters with ldquodoes not equalrdquo rules will always match Workaround Do not disable RADIUS

                            NIOS-21512 (39917)

                            When you stop the DNS service of an independent appliance with temporary DNS and DHCP licenses Grid Manager displays the Restart Services panel regardless of which function you select

                            NIOS-21499 (38968)

                            An admin cannot display DNS views created by other admins during the same browser session To display the DNS views created by other admins you must log out and log in again

                            NIOS-19853 (31668)

                            Grid Manager does not display an error when you move a DNS view to a network view that contains a host record that has the same MAC address as a host record in the DNS view that is being moved

                            NIOS-19144 (30208)

                            Grid Manager does not sort columns correctly in the IPAM and Network list panels when the columns contain UTF-8 data

                            NIOS-18163 (27831)

                            The appliance allows users with read-only permission to A records to view DNSSEC resource records as well

                            NIOS-17636 (26233)

                            Syslog messages generated during a TFTP file transfer display the incorrect time zone

                            NIOS-17513 (26080)

                            Adding updating or deleting reverse zones could fail due to unsupported PTR records in the root zone

                            PAPIPASS-39

                            When you use Mozilla Firefox 16x 17x or Mozilla Firefox Beta 180b3 browser the hidden password in the Add Administrator Wizard of Grid Manager may disappear when you click the Password field after you have confirmed the password This is a known issue when you use Firefox browsers

                            MME-154 When a NIOS user deletes a Microsoft AD domainrsquos primary zones and subzones NIOS should display a more specific message warning users about the consequences of the operation instead of the general warning message it currently displays

                            MME-129 When a Microsoft admin creates a delegation on the Microsoft server and the delegation is synchronized to the NIOS appliance the glue A record of the delegation name server is synchronized to the appliance as a manually created record If on the NIOS appliance an admin changes the IP address on the NS record of the delegation name server two A glue records are generated one with the original address one with the new address NIOS retains the original glue A record because itrsquos marked as a manually created record and it can only be changed or deleted either manually on Grid Manager or through the API When synchronization occurs the Microsoft server correctly updates the existing glue A record and does not retain the original Note that NIOS retains the original A record only after the initial update If you update the A record again NIOS just updates the existing record without retaining the original

                            MME-23 NIOS displays an ldquoInternal Errorrdquo message when you try to apply a quick filter for a range that equals 1 when you display a range in the IPv4 Microsoft Superscopes tab

                            MME-6 If you add a hostname to the Target field of an SRV record on Grid Manager when the member synchronizes the SRV record to a Microsoft server it adds a new SRV record with the hostname instead of modifying the existing record

                            NIOS 701 Release Notes

                            copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 21 of 21 400-0579-001 Rev A 1212015

                            MSSS-11 (45296)

                            When you run a discovery on a network served by Microsoft servers and Grid Manager discovers a MAC address that does not match any of the fixed addresses associated with an IP address it reports a conflict and lists the associated fixed address objects in the Related Objects table You cannot select which fixed address to resolve in the Related Objects table You can only resolve the conflict for the first address

                            VNIOS-36 (41215)

                            If a virtual NIOS member does not start up due to a license violation Grid Manager displays the status of the vNIOS member as ldquoonlinerunningrdquo even though the member is not online

                            • INTRODUCTION
                              • Supported Platforms
                                • NEW FEATURES
                                  • NIOS 700
                                    • CHANGES TO DEFAULT BEHAVIOR
                                      • NIOS 700
                                      • NIOS 6x Releases
                                        • CHANGES TO Infoblox API and RESTful API
                                          • RESTful API Deprecation and Backward Compatibility Policy
                                          • NIOS 70x
                                          • NIOS 6x Releases
                                            • UPGRADE GUIDELINES
                                              • Upgrading to NIOS 70x
                                                • BEFORE YOU INSTALL
                                                • ACCESSING GRID MANAGER
                                                • ADDRESSED VULNERABILITIES
                                                • RESOLVED ISSUES
                                                  • Fixed in 701
                                                  • Fixed in 700
                                                    • KNOWN GENERAL ISSUES

                              NIOS 701 Release Notes

                              copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 15 of 21 400-0579-001 Rev A 1212015

                              NIOS-49934 Major API On rare occasions searching with return_methods could result in incorrect PAPI results

                              NIOS-49847 Major The appliance returned an error when users tried to disable GSS-TSIG and remove the keys

                              NIOS-49826 Major Could not start DNS service on the Grid Secondary for a zone that had an external Primary while moving the LAN2 IP address from one member to the other

                              NIOS-49809 Major In a network template users could not save values for an extensible attribute that was a ldquolistrdquo type

                              NIOS-49735 Major The status of a Microsoft server was ldquoConnectingrdquo even when synchronization was in progress

                              NIOS-49505 Major High disk space usage was observed after enabling ldquoCapture DNS Queriesrdquo and ldquoCapture DNS Responsesrdquo

                              NIOS-49473 Major On rare occasions the Grid Master rebooted and went offline

                              NIOS-49349 Major The infobloxlog captured bloxTools user password in plain text

                              NIOS-49339 Major Grid Manager access was denied due to a missing object in the backup file

                              NIOS-49137 Major Advanced DNS Protection An unexpected HA failover occurred due to a general protection fault

                              NIOS-48437 Major DNS latency for DNS responses from cache was higher than usual for a duration of a couple seconds

                              NIOS-48009 Major A schedule upgrade did not function properly if the HA Grid Master had not replicated the schedule to the passive node before the upgrade started

                              NIOS-47994 Major DHCP service failed to start due to invalid DHCP option spaces defined in the DHCP configuration file

                              NIOS-50571 Minor Added descriptions about VLAN tag and DSCP support for TE-1400 series appliances to the Infoblox NIOS Administrator Guide

                              NIOS-50466 Minor DNS service startup took longer than expected due to journal file fragmentation

                              NIOS-50430 Minor Redefined the description for ldquoinfoblox-deny-rpzrdquo in the Infoblox NIOS Administrator Guide

                              NIOS-50401 Minor When associating a network with a Microsoft site an error message was displayed in the background instead of inside the editor

                              NIOS-50366 Minor Updated the CSV Import Reference to include the file format for ldquoresponsepolicyipaddressrdquo objects

                              NIOS-50267 Minor Unable to perform a discovery for a Microsoft managed subnet

                              NIOS-49986 Minor Updated IP addresses used in example in the Infoblox NIOS Administrator Guide

                              NIOS-49838 Minor Could not transfer support bundle using the transfer_supportbundle command

                              NIOS-49816 Minor The Discoverer field value was truncated in the IP MAP viewer under the Discovered Data tab

                              NIOS-49787 Minor The appliance logged excessive debugging messages

                              NIOS 701 Release Notes

                              copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 16 of 21 400-0579-001 Rev A 1212015

                              NIOS-48037 Minor Value for the extensible attribute ldquoSiterdquo was not displayed in the Lease Selector when

                              users tried to connect to an auto-provisioned member

                              NIOS-50399 Enhance Enhanced the ldquoConvertrdquo button to also appear in the IPAM home page

                              Severity Levels Severity Description

                              Critical Core network services are significantly impacted Major Network services are impacted but there is an available workaround Moderate Some loss of secondary services or configuration abilities Minor Minor functional or UI issue Enhance An enhancement to the product

                              KNOWN GENERAL ISSUES

                              ID Summary

                              NIOS-51323 DNS Traffic Control The appliance may return a timeout error while loading the Traffic Management tab in Grid Manager if you have configured health monitoring for a lot of DTC servers

                              NIOS-51287 Cloud Network Automation Modifying resource records through the cloud API will cause extensible attribute values to be removed

                              NIOS-51235 In a Multi-Grid configuration converting network connectivity for the Master Grid and its sub Grids to IPv6 only is not supported even though Grid Manager may allow you to do so

                              NIOS-51134 Infoblox appliances currently do not support HP passive copper cables

                              NIOS-51054 After you upgrade to NIOS 700 Infoblox recommends that you back up the configuration after you change network connectivity to a different mode (IPv4 IPv6 or IPv4 and IPv6 dual mode) Restoring an old backup by performing a forced restore may prevent some Grid members from rejoining the Grid after the restore

                              NIOS-50997 In this release the appliance does not automatically create a reverse-mapping zones for 1 for DNS servers that support IPv6

                              NIOS-50873 When you enable DNS and DHCP services for IPv6 only DDNS updates may not function properly for certain configurations Infoblox recommends that you do not enable DDNS updates in an IPv6-only Grid

                              NIOS-50859 Creating custom IPv6 NS records and pointing a zone to a particular IPv6 name server is not supported in this release

                              NIOS-50994 Cloud Network Automation When there is no tenant associated with a network or VM or if a network or VM is created by a cloud adapter but the tenant ID is not specified in the cloud API request the Name or ID column for the tenant or VM is left blank in Grid Manager which implies ldquoNArdquo or not applicable for the specified network or VM

                              NIOS 701 Release Notes

                              copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 17 of 21 400-0579-001 Rev A 1212015

                              NA Reporting When there is too much data being displayed in a graph data can overlap each other and make it difficult for viewing You can expand the graph to view specific data by stretching the graph on display However you will not be able to download the expanded graph in a PDF Workaround Right-click the expanded graph and then select This Frame -gt Print Frame from the drop-down menu to print the graph

                              NIOS-49238 Network Insight Under certain circumstances deleting networks may not remove the corresponding IP helper addresses from the device configuration

                              NIOS-49123 Network Insight When scheduling a discovery or port control blackout the scheduled time and time zone will always be standard time No time adjustments are made if the selected time zone is currently in daylight savings time and no adjustments are made when the time zone switches to daylight savings time

                              NIOS-49107 Network Insight If a recurring port control blackout is scheduled and it includes the current time port control tasks will be delayed during the current blackout period However you may not be warned until the next blackout period If a recurring discovery blackout is scheduled and it includes the current time the Discover Now functionality may not be blocked until the next blackout period

                              AUGUSTA2-1606

                              Network Insight Some devices such as the Cisco 3750X may report interfaces (that are not actually functional) as available through SNMP which could cause Port Control jobs on these non-functional interfaces to fail

                              NIOS-48944 Reporting When there are disconnected data points in the reporting data for reports (such as the DNS Query Rate by Query Type report) that support the stacked area panel type the stacked area that represents the disconnected data in the PDF report may not fill up accordingly and may cause it to look like a line chart when it is actually a stacked area chart Workaround Interpret the information correctly when reading the stacked area charts that contain disconnected data points

                              NIOS-48912 Network Insight Is a device is not connected to another host through a network the appliance will not be able to detect the Voice VLAN information

                              NIOS-48897 Network Insight Alcatel Omniswitches can operate in two modesmdashWorking mode and Certified mode Alcatel OmniSwitch 6000 devices must run in Working mode to allow Port Control jobs to work on these devices

                              NIOS-48704 Reporting When you configure a search for Top Devices Denied an IP Address using Member Network View Network and CIDR as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

                              NIOS-48560 Network Insight Before joining the Network Data Consolidator to the Grid use the CLI command reset net-automation database to ensure that previously discovered device information is removed from the database

                              NIOS-48399 You cannot restore the existing deleted resource records from the Recycle Bin after you promote a Grid Master Candidate to the Grid Master

                              NIOS-48311 On the IB-4010 appliance the maximum resource records allowed in a single signing zone is 800K not 25 of the object limit as in other platforms Exceeding this limit may result in a system restart

                              NIOS-48135 bloxTools data prior to NIOS 640 cannot be restored on NIOS 611x Workaround Upgrade to NIOS 64x first to get a backup before upgrading to NIOS 611x

                              NIOS 701 Release Notes

                              copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 18 of 21 400-0579-001 Rev A 1212015

                              NIOS-48030 You may not be able to log in to the bloxTools Workflow environment if you download the snapin-workflow file from the bloxTools Community site

                              NIOS-47959 Through the API and RESTful API users can add records and data without entering values for required extensible attributes Users cannot do the same through Grid Manager

                              NIOS-46356 An upgrade may fail if you clone reports and searches with duplicate names for the following reports DNS Query Rate by Server DNS Daily Query Rate by Server DNS Daily Peak Hour Query Rate by Server DHCP Device Operating System Trend DHCP Top Device Operating System and Traffic Rate

                              NIOS-46290 In some scenarios upgrading from NIOS 67x to NIOS 610x on an Infoblox-4030 appliance may require a manual restart to complete the upgrade

                              NIOS-46102 Advanced DNS Protection You may not be able to join an independent appliance to the Grid if the appliance has threat protection service enabled and only the LAN interface configured Workaround Disable threat protection service on the appliance before joining the Grid or configure the MGMT port and enable VPN on MGMT before joining the offline appliance to the Grid

                              NIOS-46051 Reporting When you configure a search for Threat Protect Event Count by Severity Trend using Member Category and Rule ID as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

                              NIOS-45906 Network Insight On rare occasions when there is incomplete inaccurate or misinterpreted data in discovered spanning tree information the appliance may not be able to determine the correct switch to which an end host is attached In this scenario the appliance may display inaccurate discovered data

                              NIOS-45904 Network Insight In Grid Manager the same end host on different VLANs may appear as duplicates that contain the same VLAN information

                              NIOS-45872 Content in the bloxHub widget on the Status Dashboard may not be displayed in certain versions of Google Chrome Mozilla FireFox and Microsoft Internet Explorer browsers due to security updates implemented by these browsers Workarounds For Chrome Click the security shield icon next to the URL and select Load unsafe script For FireFox Click the security shield icon next to the URL and select Disable Protection on This Page from the drop-down list For IE Click Show all content in the Only secure content is displayed message bar at the bottom of the page

                              NIOS-45598 Network Insight When a seed router is specified for an IP address that has already been assigned as a fixed address the IP will still be discovered even if the fixed address is excluded from discovery

                              NIOS-45233 Reporting When you use Microsoft Internet Explorer 10x and disable ldquoCompatibility Viewrdquo you may not be able to view reports in the Reporting tab Workaround In the Internet Explorer 10 browser go to Tools -gt Compatibility View to enable the feature

                              NIOS-45220 When you upgrade from NIOS 51r6-12 or earlier releases the Try Snapinstall option may not be available in the bloxTools environment after the upgrade Workaround Stop bloxTools service on the member console connect to the member through the CLI and execute the set bloxtools reset all command Once the reset process is complete restart the bloxTools service to access the Try Snapinstall option

                              NIOS 701 Release Notes

                              copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 19 of 21 400-0579-001 Rev A 1212015

                              VLAN-324 If you have assigned multiple VLANs to the LAN1 or LAN2 interfaces on the appliance you may receive messages about having ldquomultiple interfaces that match the same subnetrdquo during dhcpd process startups or restarts Note that these are not error messages and no actions are required

                              NIOS-44055 If you use certain versions of Mozilla FireFox to run Grid Manager the auto-detected time zone feature may not function properly even if you have enabled it in your User Profile

                              NIOS-43957 When you upgrade from NIOS 66x or earlier releases the email address in the SOA resource record that was entered in punycode will be converted into IDN (Internationalized Domain Name) after the upgrade Workaround Convert the IDN back to punycode using the IDN converter utility through Grid Manager

                              NIOS-43569 You may not be able to view reverse-mapping zones in an internal DNS view Workaround Set the table size to 10 in User Profile log out and then log back in to the system again

                              NIOS-41136 Reporting When you use certain versions of Mozilla Firefox and Google Chrome browsers on Windows 7 or Linux you may not be able to properly print reports

                              NIOS-39922 On Trinzic 2200 series appliances it may take up to three minutes for the LOM (Light On Management) LED to stop blinking after you have disabled the LOM feature

                              NIOS-38870 When you change the member type of an appliance from Infoblox to vNIOS the appliance might display an error message indicating that all network port settings of the vNIOS member must be changed to Automatic Workaround Through the Infoblox API use InfobloxGridMember and the functions lan_port_duplex( ) and lan_port_speed ( ) to change the network port settings for the vNIOS member

                              NIOS-38579 Reporting If you have a quick filter that includes a filter criterion with report comment equals to a value that NIOS automatically translates to another value the quick filter may not function properly after an upgrade to NIOS 65 or 66 NIOS automatically translates the following ldquoIPAM Utilizationrdquo to ldquoDDI Utilizationrdquo ldquoDNS Zone Statistics per DNS Viewrdquo to ldquoDNS Statistics per DNS Viewrdquo ldquoDNS Zone Statistics per DNS Zonerdquo to ldquoDNS Statistics per Zonerdquo ldquoDNS Member QPS Trendrdquo to ldquoDNS Query Rate by Serverrdquo and ldquoDNS Queries per Second Trendrdquo to ldquoDNS Query Rate by Query Typerdquo Workaround 1 Edit the original report comment values to match the translated values For example if you have entered ldquoIPAM Utilizationrdquo in the comment field of a report change it to ldquoDDI Utilizationrdquo Workaround 2 Edit the quick filter names to match the original comment values For example if you have entered ldquoQF1rdquo as a quick filter name and ldquoIPAM Utilizationrdquo as the report comment change the quick filter name to ldquoIPAM Utilizationrdquo

                              NIOS-37415 Users cannot execute Trinzic Automation Engine (TAE) if they log out of NetMRI during an active NetMRI session

                              NIOS-33600 There is an issue with SafeNet HSMs in that configuration changes do not immediately take effect such as when adding a new member to an existing SafeNet HSM Group deleting a client from the HSM or making member changes You can perform a forced restart of services to apply the changes immediately

                              NIOS-31864 Modifying a zone from a client increments the zonersquos serial number even if the zone contents did not change This causes unnecessary AXFRs to secondary servers and if the zone is served by a Microsoft Server that is managed in read-write mode it causes extra synchronizations as well

                              NIOS 701 Release Notes

                              copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 20 of 21 400-0579-001 Rev A 1212015

                              NIOS-31501 When a Microsoft server is the primary server for a zone and another Microsoft server is hosting the same zone as a stub zone and the NIOS appliance synchronizes DNS data with only one of these zones it will synchronize the zone as an authoritative or stub zone depending on which Microsoft server it synchronizes with first For more information please refer to KB article 17593

                              NIOS-25064 (45488)

                              If you configured a member DHCP server to authenticate DHCP clients with a RADIUS authentication server group and RADIUS is disabled (the server group is disabled all RADIUS servers in the group are disabled or the member DHCP server was not assigned an authentication server group) NAC filters with ldquodoes not equalrdquo rules will always match Workaround Do not disable RADIUS

                              NIOS-21512 (39917)

                              When you stop the DNS service of an independent appliance with temporary DNS and DHCP licenses Grid Manager displays the Restart Services panel regardless of which function you select

                              NIOS-21499 (38968)

                              An admin cannot display DNS views created by other admins during the same browser session To display the DNS views created by other admins you must log out and log in again

                              NIOS-19853 (31668)

                              Grid Manager does not display an error when you move a DNS view to a network view that contains a host record that has the same MAC address as a host record in the DNS view that is being moved

                              NIOS-19144 (30208)

                              Grid Manager does not sort columns correctly in the IPAM and Network list panels when the columns contain UTF-8 data

                              NIOS-18163 (27831)

                              The appliance allows users with read-only permission to A records to view DNSSEC resource records as well

                              NIOS-17636 (26233)

                              Syslog messages generated during a TFTP file transfer display the incorrect time zone

                              NIOS-17513 (26080)

                              Adding updating or deleting reverse zones could fail due to unsupported PTR records in the root zone

                              PAPIPASS-39

                              When you use Mozilla Firefox 16x 17x or Mozilla Firefox Beta 180b3 browser the hidden password in the Add Administrator Wizard of Grid Manager may disappear when you click the Password field after you have confirmed the password This is a known issue when you use Firefox browsers

                              MME-154 When a NIOS user deletes a Microsoft AD domainrsquos primary zones and subzones NIOS should display a more specific message warning users about the consequences of the operation instead of the general warning message it currently displays

                              MME-129 When a Microsoft admin creates a delegation on the Microsoft server and the delegation is synchronized to the NIOS appliance the glue A record of the delegation name server is synchronized to the appliance as a manually created record If on the NIOS appliance an admin changes the IP address on the NS record of the delegation name server two A glue records are generated one with the original address one with the new address NIOS retains the original glue A record because itrsquos marked as a manually created record and it can only be changed or deleted either manually on Grid Manager or through the API When synchronization occurs the Microsoft server correctly updates the existing glue A record and does not retain the original Note that NIOS retains the original A record only after the initial update If you update the A record again NIOS just updates the existing record without retaining the original

                              MME-23 NIOS displays an ldquoInternal Errorrdquo message when you try to apply a quick filter for a range that equals 1 when you display a range in the IPv4 Microsoft Superscopes tab

                              MME-6 If you add a hostname to the Target field of an SRV record on Grid Manager when the member synchronizes the SRV record to a Microsoft server it adds a new SRV record with the hostname instead of modifying the existing record

                              NIOS 701 Release Notes

                              copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 21 of 21 400-0579-001 Rev A 1212015

                              MSSS-11 (45296)

                              When you run a discovery on a network served by Microsoft servers and Grid Manager discovers a MAC address that does not match any of the fixed addresses associated with an IP address it reports a conflict and lists the associated fixed address objects in the Related Objects table You cannot select which fixed address to resolve in the Related Objects table You can only resolve the conflict for the first address

                              VNIOS-36 (41215)

                              If a virtual NIOS member does not start up due to a license violation Grid Manager displays the status of the vNIOS member as ldquoonlinerunningrdquo even though the member is not online

                              • INTRODUCTION
                                • Supported Platforms
                                  • NEW FEATURES
                                    • NIOS 700
                                      • CHANGES TO DEFAULT BEHAVIOR
                                        • NIOS 700
                                        • NIOS 6x Releases
                                          • CHANGES TO Infoblox API and RESTful API
                                            • RESTful API Deprecation and Backward Compatibility Policy
                                            • NIOS 70x
                                            • NIOS 6x Releases
                                              • UPGRADE GUIDELINES
                                                • Upgrading to NIOS 70x
                                                  • BEFORE YOU INSTALL
                                                  • ACCESSING GRID MANAGER
                                                  • ADDRESSED VULNERABILITIES
                                                  • RESOLVED ISSUES
                                                    • Fixed in 701
                                                    • Fixed in 700
                                                      • KNOWN GENERAL ISSUES

                                NIOS 701 Release Notes

                                copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 16 of 21 400-0579-001 Rev A 1212015

                                NIOS-48037 Minor Value for the extensible attribute ldquoSiterdquo was not displayed in the Lease Selector when

                                users tried to connect to an auto-provisioned member

                                NIOS-50399 Enhance Enhanced the ldquoConvertrdquo button to also appear in the IPAM home page

                                Severity Levels Severity Description

                                Critical Core network services are significantly impacted Major Network services are impacted but there is an available workaround Moderate Some loss of secondary services or configuration abilities Minor Minor functional or UI issue Enhance An enhancement to the product

                                KNOWN GENERAL ISSUES

                                ID Summary

                                NIOS-51323 DNS Traffic Control The appliance may return a timeout error while loading the Traffic Management tab in Grid Manager if you have configured health monitoring for a lot of DTC servers

                                NIOS-51287 Cloud Network Automation Modifying resource records through the cloud API will cause extensible attribute values to be removed

                                NIOS-51235 In a Multi-Grid configuration converting network connectivity for the Master Grid and its sub Grids to IPv6 only is not supported even though Grid Manager may allow you to do so

                                NIOS-51134 Infoblox appliances currently do not support HP passive copper cables

                                NIOS-51054 After you upgrade to NIOS 700 Infoblox recommends that you back up the configuration after you change network connectivity to a different mode (IPv4 IPv6 or IPv4 and IPv6 dual mode) Restoring an old backup by performing a forced restore may prevent some Grid members from rejoining the Grid after the restore

                                NIOS-50997 In this release the appliance does not automatically create a reverse-mapping zones for 1 for DNS servers that support IPv6

                                NIOS-50873 When you enable DNS and DHCP services for IPv6 only DDNS updates may not function properly for certain configurations Infoblox recommends that you do not enable DDNS updates in an IPv6-only Grid

                                NIOS-50859 Creating custom IPv6 NS records and pointing a zone to a particular IPv6 name server is not supported in this release

                                NIOS-50994 Cloud Network Automation When there is no tenant associated with a network or VM or if a network or VM is created by a cloud adapter but the tenant ID is not specified in the cloud API request the Name or ID column for the tenant or VM is left blank in Grid Manager which implies ldquoNArdquo or not applicable for the specified network or VM

                                NIOS 701 Release Notes

                                copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 17 of 21 400-0579-001 Rev A 1212015

                                NA Reporting When there is too much data being displayed in a graph data can overlap each other and make it difficult for viewing You can expand the graph to view specific data by stretching the graph on display However you will not be able to download the expanded graph in a PDF Workaround Right-click the expanded graph and then select This Frame -gt Print Frame from the drop-down menu to print the graph

                                NIOS-49238 Network Insight Under certain circumstances deleting networks may not remove the corresponding IP helper addresses from the device configuration

                                NIOS-49123 Network Insight When scheduling a discovery or port control blackout the scheduled time and time zone will always be standard time No time adjustments are made if the selected time zone is currently in daylight savings time and no adjustments are made when the time zone switches to daylight savings time

                                NIOS-49107 Network Insight If a recurring port control blackout is scheduled and it includes the current time port control tasks will be delayed during the current blackout period However you may not be warned until the next blackout period If a recurring discovery blackout is scheduled and it includes the current time the Discover Now functionality may not be blocked until the next blackout period

                                AUGUSTA2-1606

                                Network Insight Some devices such as the Cisco 3750X may report interfaces (that are not actually functional) as available through SNMP which could cause Port Control jobs on these non-functional interfaces to fail

                                NIOS-48944 Reporting When there are disconnected data points in the reporting data for reports (such as the DNS Query Rate by Query Type report) that support the stacked area panel type the stacked area that represents the disconnected data in the PDF report may not fill up accordingly and may cause it to look like a line chart when it is actually a stacked area chart Workaround Interpret the information correctly when reading the stacked area charts that contain disconnected data points

                                NIOS-48912 Network Insight Is a device is not connected to another host through a network the appliance will not be able to detect the Voice VLAN information

                                NIOS-48897 Network Insight Alcatel Omniswitches can operate in two modesmdashWorking mode and Certified mode Alcatel OmniSwitch 6000 devices must run in Working mode to allow Port Control jobs to work on these devices

                                NIOS-48704 Reporting When you configure a search for Top Devices Denied an IP Address using Member Network View Network and CIDR as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

                                NIOS-48560 Network Insight Before joining the Network Data Consolidator to the Grid use the CLI command reset net-automation database to ensure that previously discovered device information is removed from the database

                                NIOS-48399 You cannot restore the existing deleted resource records from the Recycle Bin after you promote a Grid Master Candidate to the Grid Master

                                NIOS-48311 On the IB-4010 appliance the maximum resource records allowed in a single signing zone is 800K not 25 of the object limit as in other platforms Exceeding this limit may result in a system restart

                                NIOS-48135 bloxTools data prior to NIOS 640 cannot be restored on NIOS 611x Workaround Upgrade to NIOS 64x first to get a backup before upgrading to NIOS 611x

                                NIOS 701 Release Notes

                                copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 18 of 21 400-0579-001 Rev A 1212015

                                NIOS-48030 You may not be able to log in to the bloxTools Workflow environment if you download the snapin-workflow file from the bloxTools Community site

                                NIOS-47959 Through the API and RESTful API users can add records and data without entering values for required extensible attributes Users cannot do the same through Grid Manager

                                NIOS-46356 An upgrade may fail if you clone reports and searches with duplicate names for the following reports DNS Query Rate by Server DNS Daily Query Rate by Server DNS Daily Peak Hour Query Rate by Server DHCP Device Operating System Trend DHCP Top Device Operating System and Traffic Rate

                                NIOS-46290 In some scenarios upgrading from NIOS 67x to NIOS 610x on an Infoblox-4030 appliance may require a manual restart to complete the upgrade

                                NIOS-46102 Advanced DNS Protection You may not be able to join an independent appliance to the Grid if the appliance has threat protection service enabled and only the LAN interface configured Workaround Disable threat protection service on the appliance before joining the Grid or configure the MGMT port and enable VPN on MGMT before joining the offline appliance to the Grid

                                NIOS-46051 Reporting When you configure a search for Threat Protect Event Count by Severity Trend using Member Category and Rule ID as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

                                NIOS-45906 Network Insight On rare occasions when there is incomplete inaccurate or misinterpreted data in discovered spanning tree information the appliance may not be able to determine the correct switch to which an end host is attached In this scenario the appliance may display inaccurate discovered data

                                NIOS-45904 Network Insight In Grid Manager the same end host on different VLANs may appear as duplicates that contain the same VLAN information

                                NIOS-45872 Content in the bloxHub widget on the Status Dashboard may not be displayed in certain versions of Google Chrome Mozilla FireFox and Microsoft Internet Explorer browsers due to security updates implemented by these browsers Workarounds For Chrome Click the security shield icon next to the URL and select Load unsafe script For FireFox Click the security shield icon next to the URL and select Disable Protection on This Page from the drop-down list For IE Click Show all content in the Only secure content is displayed message bar at the bottom of the page

                                NIOS-45598 Network Insight When a seed router is specified for an IP address that has already been assigned as a fixed address the IP will still be discovered even if the fixed address is excluded from discovery

                                NIOS-45233 Reporting When you use Microsoft Internet Explorer 10x and disable ldquoCompatibility Viewrdquo you may not be able to view reports in the Reporting tab Workaround In the Internet Explorer 10 browser go to Tools -gt Compatibility View to enable the feature

                                NIOS-45220 When you upgrade from NIOS 51r6-12 or earlier releases the Try Snapinstall option may not be available in the bloxTools environment after the upgrade Workaround Stop bloxTools service on the member console connect to the member through the CLI and execute the set bloxtools reset all command Once the reset process is complete restart the bloxTools service to access the Try Snapinstall option

                                NIOS 701 Release Notes

                                copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 19 of 21 400-0579-001 Rev A 1212015

                                VLAN-324 If you have assigned multiple VLANs to the LAN1 or LAN2 interfaces on the appliance you may receive messages about having ldquomultiple interfaces that match the same subnetrdquo during dhcpd process startups or restarts Note that these are not error messages and no actions are required

                                NIOS-44055 If you use certain versions of Mozilla FireFox to run Grid Manager the auto-detected time zone feature may not function properly even if you have enabled it in your User Profile

                                NIOS-43957 When you upgrade from NIOS 66x or earlier releases the email address in the SOA resource record that was entered in punycode will be converted into IDN (Internationalized Domain Name) after the upgrade Workaround Convert the IDN back to punycode using the IDN converter utility through Grid Manager

                                NIOS-43569 You may not be able to view reverse-mapping zones in an internal DNS view Workaround Set the table size to 10 in User Profile log out and then log back in to the system again

                                NIOS-41136 Reporting When you use certain versions of Mozilla Firefox and Google Chrome browsers on Windows 7 or Linux you may not be able to properly print reports

                                NIOS-39922 On Trinzic 2200 series appliances it may take up to three minutes for the LOM (Light On Management) LED to stop blinking after you have disabled the LOM feature

                                NIOS-38870 When you change the member type of an appliance from Infoblox to vNIOS the appliance might display an error message indicating that all network port settings of the vNIOS member must be changed to Automatic Workaround Through the Infoblox API use InfobloxGridMember and the functions lan_port_duplex( ) and lan_port_speed ( ) to change the network port settings for the vNIOS member

                                NIOS-38579 Reporting If you have a quick filter that includes a filter criterion with report comment equals to a value that NIOS automatically translates to another value the quick filter may not function properly after an upgrade to NIOS 65 or 66 NIOS automatically translates the following ldquoIPAM Utilizationrdquo to ldquoDDI Utilizationrdquo ldquoDNS Zone Statistics per DNS Viewrdquo to ldquoDNS Statistics per DNS Viewrdquo ldquoDNS Zone Statistics per DNS Zonerdquo to ldquoDNS Statistics per Zonerdquo ldquoDNS Member QPS Trendrdquo to ldquoDNS Query Rate by Serverrdquo and ldquoDNS Queries per Second Trendrdquo to ldquoDNS Query Rate by Query Typerdquo Workaround 1 Edit the original report comment values to match the translated values For example if you have entered ldquoIPAM Utilizationrdquo in the comment field of a report change it to ldquoDDI Utilizationrdquo Workaround 2 Edit the quick filter names to match the original comment values For example if you have entered ldquoQF1rdquo as a quick filter name and ldquoIPAM Utilizationrdquo as the report comment change the quick filter name to ldquoIPAM Utilizationrdquo

                                NIOS-37415 Users cannot execute Trinzic Automation Engine (TAE) if they log out of NetMRI during an active NetMRI session

                                NIOS-33600 There is an issue with SafeNet HSMs in that configuration changes do not immediately take effect such as when adding a new member to an existing SafeNet HSM Group deleting a client from the HSM or making member changes You can perform a forced restart of services to apply the changes immediately

                                NIOS-31864 Modifying a zone from a client increments the zonersquos serial number even if the zone contents did not change This causes unnecessary AXFRs to secondary servers and if the zone is served by a Microsoft Server that is managed in read-write mode it causes extra synchronizations as well

                                NIOS 701 Release Notes

                                copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 20 of 21 400-0579-001 Rev A 1212015

                                NIOS-31501 When a Microsoft server is the primary server for a zone and another Microsoft server is hosting the same zone as a stub zone and the NIOS appliance synchronizes DNS data with only one of these zones it will synchronize the zone as an authoritative or stub zone depending on which Microsoft server it synchronizes with first For more information please refer to KB article 17593

                                NIOS-25064 (45488)

                                If you configured a member DHCP server to authenticate DHCP clients with a RADIUS authentication server group and RADIUS is disabled (the server group is disabled all RADIUS servers in the group are disabled or the member DHCP server was not assigned an authentication server group) NAC filters with ldquodoes not equalrdquo rules will always match Workaround Do not disable RADIUS

                                NIOS-21512 (39917)

                                When you stop the DNS service of an independent appliance with temporary DNS and DHCP licenses Grid Manager displays the Restart Services panel regardless of which function you select

                                NIOS-21499 (38968)

                                An admin cannot display DNS views created by other admins during the same browser session To display the DNS views created by other admins you must log out and log in again

                                NIOS-19853 (31668)

                                Grid Manager does not display an error when you move a DNS view to a network view that contains a host record that has the same MAC address as a host record in the DNS view that is being moved

                                NIOS-19144 (30208)

                                Grid Manager does not sort columns correctly in the IPAM and Network list panels when the columns contain UTF-8 data

                                NIOS-18163 (27831)

                                The appliance allows users with read-only permission to A records to view DNSSEC resource records as well

                                NIOS-17636 (26233)

                                Syslog messages generated during a TFTP file transfer display the incorrect time zone

                                NIOS-17513 (26080)

                                Adding updating or deleting reverse zones could fail due to unsupported PTR records in the root zone

                                PAPIPASS-39

                                When you use Mozilla Firefox 16x 17x or Mozilla Firefox Beta 180b3 browser the hidden password in the Add Administrator Wizard of Grid Manager may disappear when you click the Password field after you have confirmed the password This is a known issue when you use Firefox browsers

                                MME-154 When a NIOS user deletes a Microsoft AD domainrsquos primary zones and subzones NIOS should display a more specific message warning users about the consequences of the operation instead of the general warning message it currently displays

                                MME-129 When a Microsoft admin creates a delegation on the Microsoft server and the delegation is synchronized to the NIOS appliance the glue A record of the delegation name server is synchronized to the appliance as a manually created record If on the NIOS appliance an admin changes the IP address on the NS record of the delegation name server two A glue records are generated one with the original address one with the new address NIOS retains the original glue A record because itrsquos marked as a manually created record and it can only be changed or deleted either manually on Grid Manager or through the API When synchronization occurs the Microsoft server correctly updates the existing glue A record and does not retain the original Note that NIOS retains the original A record only after the initial update If you update the A record again NIOS just updates the existing record without retaining the original

                                MME-23 NIOS displays an ldquoInternal Errorrdquo message when you try to apply a quick filter for a range that equals 1 when you display a range in the IPv4 Microsoft Superscopes tab

                                MME-6 If you add a hostname to the Target field of an SRV record on Grid Manager when the member synchronizes the SRV record to a Microsoft server it adds a new SRV record with the hostname instead of modifying the existing record

                                NIOS 701 Release Notes

                                copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 21 of 21 400-0579-001 Rev A 1212015

                                MSSS-11 (45296)

                                When you run a discovery on a network served by Microsoft servers and Grid Manager discovers a MAC address that does not match any of the fixed addresses associated with an IP address it reports a conflict and lists the associated fixed address objects in the Related Objects table You cannot select which fixed address to resolve in the Related Objects table You can only resolve the conflict for the first address

                                VNIOS-36 (41215)

                                If a virtual NIOS member does not start up due to a license violation Grid Manager displays the status of the vNIOS member as ldquoonlinerunningrdquo even though the member is not online

                                • INTRODUCTION
                                  • Supported Platforms
                                    • NEW FEATURES
                                      • NIOS 700
                                        • CHANGES TO DEFAULT BEHAVIOR
                                          • NIOS 700
                                          • NIOS 6x Releases
                                            • CHANGES TO Infoblox API and RESTful API
                                              • RESTful API Deprecation and Backward Compatibility Policy
                                              • NIOS 70x
                                              • NIOS 6x Releases
                                                • UPGRADE GUIDELINES
                                                  • Upgrading to NIOS 70x
                                                    • BEFORE YOU INSTALL
                                                    • ACCESSING GRID MANAGER
                                                    • ADDRESSED VULNERABILITIES
                                                    • RESOLVED ISSUES
                                                      • Fixed in 701
                                                      • Fixed in 700
                                                        • KNOWN GENERAL ISSUES

                                  NIOS 701 Release Notes

                                  copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 17 of 21 400-0579-001 Rev A 1212015

                                  NA Reporting When there is too much data being displayed in a graph data can overlap each other and make it difficult for viewing You can expand the graph to view specific data by stretching the graph on display However you will not be able to download the expanded graph in a PDF Workaround Right-click the expanded graph and then select This Frame -gt Print Frame from the drop-down menu to print the graph

                                  NIOS-49238 Network Insight Under certain circumstances deleting networks may not remove the corresponding IP helper addresses from the device configuration

                                  NIOS-49123 Network Insight When scheduling a discovery or port control blackout the scheduled time and time zone will always be standard time No time adjustments are made if the selected time zone is currently in daylight savings time and no adjustments are made when the time zone switches to daylight savings time

                                  NIOS-49107 Network Insight If a recurring port control blackout is scheduled and it includes the current time port control tasks will be delayed during the current blackout period However you may not be warned until the next blackout period If a recurring discovery blackout is scheduled and it includes the current time the Discover Now functionality may not be blocked until the next blackout period

                                  AUGUSTA2-1606

                                  Network Insight Some devices such as the Cisco 3750X may report interfaces (that are not actually functional) as available through SNMP which could cause Port Control jobs on these non-functional interfaces to fail

                                  NIOS-48944 Reporting When there are disconnected data points in the reporting data for reports (such as the DNS Query Rate by Query Type report) that support the stacked area panel type the stacked area that represents the disconnected data in the PDF report may not fill up accordingly and may cause it to look like a line chart when it is actually a stacked area chart Workaround Interpret the information correctly when reading the stacked area charts that contain disconnected data points

                                  NIOS-48912 Network Insight Is a device is not connected to another host through a network the appliance will not be able to detect the Voice VLAN information

                                  NIOS-48897 Network Insight Alcatel Omniswitches can operate in two modesmdashWorking mode and Certified mode Alcatel OmniSwitch 6000 devices must run in Working mode to allow Port Control jobs to work on these devices

                                  NIOS-48704 Reporting When you configure a search for Top Devices Denied an IP Address using Member Network View Network and CIDR as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

                                  NIOS-48560 Network Insight Before joining the Network Data Consolidator to the Grid use the CLI command reset net-automation database to ensure that previously discovered device information is removed from the database

                                  NIOS-48399 You cannot restore the existing deleted resource records from the Recycle Bin after you promote a Grid Master Candidate to the Grid Master

                                  NIOS-48311 On the IB-4010 appliance the maximum resource records allowed in a single signing zone is 800K not 25 of the object limit as in other platforms Exceeding this limit may result in a system restart

                                  NIOS-48135 bloxTools data prior to NIOS 640 cannot be restored on NIOS 611x Workaround Upgrade to NIOS 64x first to get a backup before upgrading to NIOS 611x

                                  NIOS 701 Release Notes

                                  copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 18 of 21 400-0579-001 Rev A 1212015

                                  NIOS-48030 You may not be able to log in to the bloxTools Workflow environment if you download the snapin-workflow file from the bloxTools Community site

                                  NIOS-47959 Through the API and RESTful API users can add records and data without entering values for required extensible attributes Users cannot do the same through Grid Manager

                                  NIOS-46356 An upgrade may fail if you clone reports and searches with duplicate names for the following reports DNS Query Rate by Server DNS Daily Query Rate by Server DNS Daily Peak Hour Query Rate by Server DHCP Device Operating System Trend DHCP Top Device Operating System and Traffic Rate

                                  NIOS-46290 In some scenarios upgrading from NIOS 67x to NIOS 610x on an Infoblox-4030 appliance may require a manual restart to complete the upgrade

                                  NIOS-46102 Advanced DNS Protection You may not be able to join an independent appliance to the Grid if the appliance has threat protection service enabled and only the LAN interface configured Workaround Disable threat protection service on the appliance before joining the Grid or configure the MGMT port and enable VPN on MGMT before joining the offline appliance to the Grid

                                  NIOS-46051 Reporting When you configure a search for Threat Protect Event Count by Severity Trend using Member Category and Rule ID as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

                                  NIOS-45906 Network Insight On rare occasions when there is incomplete inaccurate or misinterpreted data in discovered spanning tree information the appliance may not be able to determine the correct switch to which an end host is attached In this scenario the appliance may display inaccurate discovered data

                                  NIOS-45904 Network Insight In Grid Manager the same end host on different VLANs may appear as duplicates that contain the same VLAN information

                                  NIOS-45872 Content in the bloxHub widget on the Status Dashboard may not be displayed in certain versions of Google Chrome Mozilla FireFox and Microsoft Internet Explorer browsers due to security updates implemented by these browsers Workarounds For Chrome Click the security shield icon next to the URL and select Load unsafe script For FireFox Click the security shield icon next to the URL and select Disable Protection on This Page from the drop-down list For IE Click Show all content in the Only secure content is displayed message bar at the bottom of the page

                                  NIOS-45598 Network Insight When a seed router is specified for an IP address that has already been assigned as a fixed address the IP will still be discovered even if the fixed address is excluded from discovery

                                  NIOS-45233 Reporting When you use Microsoft Internet Explorer 10x and disable ldquoCompatibility Viewrdquo you may not be able to view reports in the Reporting tab Workaround In the Internet Explorer 10 browser go to Tools -gt Compatibility View to enable the feature

                                  NIOS-45220 When you upgrade from NIOS 51r6-12 or earlier releases the Try Snapinstall option may not be available in the bloxTools environment after the upgrade Workaround Stop bloxTools service on the member console connect to the member through the CLI and execute the set bloxtools reset all command Once the reset process is complete restart the bloxTools service to access the Try Snapinstall option

                                  NIOS 701 Release Notes

                                  copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 19 of 21 400-0579-001 Rev A 1212015

                                  VLAN-324 If you have assigned multiple VLANs to the LAN1 or LAN2 interfaces on the appliance you may receive messages about having ldquomultiple interfaces that match the same subnetrdquo during dhcpd process startups or restarts Note that these are not error messages and no actions are required

                                  NIOS-44055 If you use certain versions of Mozilla FireFox to run Grid Manager the auto-detected time zone feature may not function properly even if you have enabled it in your User Profile

                                  NIOS-43957 When you upgrade from NIOS 66x or earlier releases the email address in the SOA resource record that was entered in punycode will be converted into IDN (Internationalized Domain Name) after the upgrade Workaround Convert the IDN back to punycode using the IDN converter utility through Grid Manager

                                  NIOS-43569 You may not be able to view reverse-mapping zones in an internal DNS view Workaround Set the table size to 10 in User Profile log out and then log back in to the system again

                                  NIOS-41136 Reporting When you use certain versions of Mozilla Firefox and Google Chrome browsers on Windows 7 or Linux you may not be able to properly print reports

                                  NIOS-39922 On Trinzic 2200 series appliances it may take up to three minutes for the LOM (Light On Management) LED to stop blinking after you have disabled the LOM feature

                                  NIOS-38870 When you change the member type of an appliance from Infoblox to vNIOS the appliance might display an error message indicating that all network port settings of the vNIOS member must be changed to Automatic Workaround Through the Infoblox API use InfobloxGridMember and the functions lan_port_duplex( ) and lan_port_speed ( ) to change the network port settings for the vNIOS member

                                  NIOS-38579 Reporting If you have a quick filter that includes a filter criterion with report comment equals to a value that NIOS automatically translates to another value the quick filter may not function properly after an upgrade to NIOS 65 or 66 NIOS automatically translates the following ldquoIPAM Utilizationrdquo to ldquoDDI Utilizationrdquo ldquoDNS Zone Statistics per DNS Viewrdquo to ldquoDNS Statistics per DNS Viewrdquo ldquoDNS Zone Statistics per DNS Zonerdquo to ldquoDNS Statistics per Zonerdquo ldquoDNS Member QPS Trendrdquo to ldquoDNS Query Rate by Serverrdquo and ldquoDNS Queries per Second Trendrdquo to ldquoDNS Query Rate by Query Typerdquo Workaround 1 Edit the original report comment values to match the translated values For example if you have entered ldquoIPAM Utilizationrdquo in the comment field of a report change it to ldquoDDI Utilizationrdquo Workaround 2 Edit the quick filter names to match the original comment values For example if you have entered ldquoQF1rdquo as a quick filter name and ldquoIPAM Utilizationrdquo as the report comment change the quick filter name to ldquoIPAM Utilizationrdquo

                                  NIOS-37415 Users cannot execute Trinzic Automation Engine (TAE) if they log out of NetMRI during an active NetMRI session

                                  NIOS-33600 There is an issue with SafeNet HSMs in that configuration changes do not immediately take effect such as when adding a new member to an existing SafeNet HSM Group deleting a client from the HSM or making member changes You can perform a forced restart of services to apply the changes immediately

                                  NIOS-31864 Modifying a zone from a client increments the zonersquos serial number even if the zone contents did not change This causes unnecessary AXFRs to secondary servers and if the zone is served by a Microsoft Server that is managed in read-write mode it causes extra synchronizations as well

                                  NIOS 701 Release Notes

                                  copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 20 of 21 400-0579-001 Rev A 1212015

                                  NIOS-31501 When a Microsoft server is the primary server for a zone and another Microsoft server is hosting the same zone as a stub zone and the NIOS appliance synchronizes DNS data with only one of these zones it will synchronize the zone as an authoritative or stub zone depending on which Microsoft server it synchronizes with first For more information please refer to KB article 17593

                                  NIOS-25064 (45488)

                                  If you configured a member DHCP server to authenticate DHCP clients with a RADIUS authentication server group and RADIUS is disabled (the server group is disabled all RADIUS servers in the group are disabled or the member DHCP server was not assigned an authentication server group) NAC filters with ldquodoes not equalrdquo rules will always match Workaround Do not disable RADIUS

                                  NIOS-21512 (39917)

                                  When you stop the DNS service of an independent appliance with temporary DNS and DHCP licenses Grid Manager displays the Restart Services panel regardless of which function you select

                                  NIOS-21499 (38968)

                                  An admin cannot display DNS views created by other admins during the same browser session To display the DNS views created by other admins you must log out and log in again

                                  NIOS-19853 (31668)

                                  Grid Manager does not display an error when you move a DNS view to a network view that contains a host record that has the same MAC address as a host record in the DNS view that is being moved

                                  NIOS-19144 (30208)

                                  Grid Manager does not sort columns correctly in the IPAM and Network list panels when the columns contain UTF-8 data

                                  NIOS-18163 (27831)

                                  The appliance allows users with read-only permission to A records to view DNSSEC resource records as well

                                  NIOS-17636 (26233)

                                  Syslog messages generated during a TFTP file transfer display the incorrect time zone

                                  NIOS-17513 (26080)

                                  Adding updating or deleting reverse zones could fail due to unsupported PTR records in the root zone

                                  PAPIPASS-39

                                  When you use Mozilla Firefox 16x 17x or Mozilla Firefox Beta 180b3 browser the hidden password in the Add Administrator Wizard of Grid Manager may disappear when you click the Password field after you have confirmed the password This is a known issue when you use Firefox browsers

                                  MME-154 When a NIOS user deletes a Microsoft AD domainrsquos primary zones and subzones NIOS should display a more specific message warning users about the consequences of the operation instead of the general warning message it currently displays

                                  MME-129 When a Microsoft admin creates a delegation on the Microsoft server and the delegation is synchronized to the NIOS appliance the glue A record of the delegation name server is synchronized to the appliance as a manually created record If on the NIOS appliance an admin changes the IP address on the NS record of the delegation name server two A glue records are generated one with the original address one with the new address NIOS retains the original glue A record because itrsquos marked as a manually created record and it can only be changed or deleted either manually on Grid Manager or through the API When synchronization occurs the Microsoft server correctly updates the existing glue A record and does not retain the original Note that NIOS retains the original A record only after the initial update If you update the A record again NIOS just updates the existing record without retaining the original

                                  MME-23 NIOS displays an ldquoInternal Errorrdquo message when you try to apply a quick filter for a range that equals 1 when you display a range in the IPv4 Microsoft Superscopes tab

                                  MME-6 If you add a hostname to the Target field of an SRV record on Grid Manager when the member synchronizes the SRV record to a Microsoft server it adds a new SRV record with the hostname instead of modifying the existing record

                                  NIOS 701 Release Notes

                                  copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 21 of 21 400-0579-001 Rev A 1212015

                                  MSSS-11 (45296)

                                  When you run a discovery on a network served by Microsoft servers and Grid Manager discovers a MAC address that does not match any of the fixed addresses associated with an IP address it reports a conflict and lists the associated fixed address objects in the Related Objects table You cannot select which fixed address to resolve in the Related Objects table You can only resolve the conflict for the first address

                                  VNIOS-36 (41215)

                                  If a virtual NIOS member does not start up due to a license violation Grid Manager displays the status of the vNIOS member as ldquoonlinerunningrdquo even though the member is not online

                                  • INTRODUCTION
                                    • Supported Platforms
                                      • NEW FEATURES
                                        • NIOS 700
                                          • CHANGES TO DEFAULT BEHAVIOR
                                            • NIOS 700
                                            • NIOS 6x Releases
                                              • CHANGES TO Infoblox API and RESTful API
                                                • RESTful API Deprecation and Backward Compatibility Policy
                                                • NIOS 70x
                                                • NIOS 6x Releases
                                                  • UPGRADE GUIDELINES
                                                    • Upgrading to NIOS 70x
                                                      • BEFORE YOU INSTALL
                                                      • ACCESSING GRID MANAGER
                                                      • ADDRESSED VULNERABILITIES
                                                      • RESOLVED ISSUES
                                                        • Fixed in 701
                                                        • Fixed in 700
                                                          • KNOWN GENERAL ISSUES

                                    NIOS 701 Release Notes

                                    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 18 of 21 400-0579-001 Rev A 1212015

                                    NIOS-48030 You may not be able to log in to the bloxTools Workflow environment if you download the snapin-workflow file from the bloxTools Community site

                                    NIOS-47959 Through the API and RESTful API users can add records and data without entering values for required extensible attributes Users cannot do the same through Grid Manager

                                    NIOS-46356 An upgrade may fail if you clone reports and searches with duplicate names for the following reports DNS Query Rate by Server DNS Daily Query Rate by Server DNS Daily Peak Hour Query Rate by Server DHCP Device Operating System Trend DHCP Top Device Operating System and Traffic Rate

                                    NIOS-46290 In some scenarios upgrading from NIOS 67x to NIOS 610x on an Infoblox-4030 appliance may require a manual restart to complete the upgrade

                                    NIOS-46102 Advanced DNS Protection You may not be able to join an independent appliance to the Grid if the appliance has threat protection service enabled and only the LAN interface configured Workaround Disable threat protection service on the appliance before joining the Grid or configure the MGMT port and enable VPN on MGMT before joining the offline appliance to the Grid

                                    NIOS-46051 Reporting When you configure a search for Threat Protect Event Count by Severity Trend using Member Category and Rule ID as alerting filters the alerts are triggered correctly but the alerting conditions are not included in the alerting email and the Query Terms field in the email may show ldquounconditionedrdquo Workaround Define the alerting and email titles to reflect the specified conditions

                                    NIOS-45906 Network Insight On rare occasions when there is incomplete inaccurate or misinterpreted data in discovered spanning tree information the appliance may not be able to determine the correct switch to which an end host is attached In this scenario the appliance may display inaccurate discovered data

                                    NIOS-45904 Network Insight In Grid Manager the same end host on different VLANs may appear as duplicates that contain the same VLAN information

                                    NIOS-45872 Content in the bloxHub widget on the Status Dashboard may not be displayed in certain versions of Google Chrome Mozilla FireFox and Microsoft Internet Explorer browsers due to security updates implemented by these browsers Workarounds For Chrome Click the security shield icon next to the URL and select Load unsafe script For FireFox Click the security shield icon next to the URL and select Disable Protection on This Page from the drop-down list For IE Click Show all content in the Only secure content is displayed message bar at the bottom of the page

                                    NIOS-45598 Network Insight When a seed router is specified for an IP address that has already been assigned as a fixed address the IP will still be discovered even if the fixed address is excluded from discovery

                                    NIOS-45233 Reporting When you use Microsoft Internet Explorer 10x and disable ldquoCompatibility Viewrdquo you may not be able to view reports in the Reporting tab Workaround In the Internet Explorer 10 browser go to Tools -gt Compatibility View to enable the feature

                                    NIOS-45220 When you upgrade from NIOS 51r6-12 or earlier releases the Try Snapinstall option may not be available in the bloxTools environment after the upgrade Workaround Stop bloxTools service on the member console connect to the member through the CLI and execute the set bloxtools reset all command Once the reset process is complete restart the bloxTools service to access the Try Snapinstall option

                                    NIOS 701 Release Notes

                                    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 19 of 21 400-0579-001 Rev A 1212015

                                    VLAN-324 If you have assigned multiple VLANs to the LAN1 or LAN2 interfaces on the appliance you may receive messages about having ldquomultiple interfaces that match the same subnetrdquo during dhcpd process startups or restarts Note that these are not error messages and no actions are required

                                    NIOS-44055 If you use certain versions of Mozilla FireFox to run Grid Manager the auto-detected time zone feature may not function properly even if you have enabled it in your User Profile

                                    NIOS-43957 When you upgrade from NIOS 66x or earlier releases the email address in the SOA resource record that was entered in punycode will be converted into IDN (Internationalized Domain Name) after the upgrade Workaround Convert the IDN back to punycode using the IDN converter utility through Grid Manager

                                    NIOS-43569 You may not be able to view reverse-mapping zones in an internal DNS view Workaround Set the table size to 10 in User Profile log out and then log back in to the system again

                                    NIOS-41136 Reporting When you use certain versions of Mozilla Firefox and Google Chrome browsers on Windows 7 or Linux you may not be able to properly print reports

                                    NIOS-39922 On Trinzic 2200 series appliances it may take up to three minutes for the LOM (Light On Management) LED to stop blinking after you have disabled the LOM feature

                                    NIOS-38870 When you change the member type of an appliance from Infoblox to vNIOS the appliance might display an error message indicating that all network port settings of the vNIOS member must be changed to Automatic Workaround Through the Infoblox API use InfobloxGridMember and the functions lan_port_duplex( ) and lan_port_speed ( ) to change the network port settings for the vNIOS member

                                    NIOS-38579 Reporting If you have a quick filter that includes a filter criterion with report comment equals to a value that NIOS automatically translates to another value the quick filter may not function properly after an upgrade to NIOS 65 or 66 NIOS automatically translates the following ldquoIPAM Utilizationrdquo to ldquoDDI Utilizationrdquo ldquoDNS Zone Statistics per DNS Viewrdquo to ldquoDNS Statistics per DNS Viewrdquo ldquoDNS Zone Statistics per DNS Zonerdquo to ldquoDNS Statistics per Zonerdquo ldquoDNS Member QPS Trendrdquo to ldquoDNS Query Rate by Serverrdquo and ldquoDNS Queries per Second Trendrdquo to ldquoDNS Query Rate by Query Typerdquo Workaround 1 Edit the original report comment values to match the translated values For example if you have entered ldquoIPAM Utilizationrdquo in the comment field of a report change it to ldquoDDI Utilizationrdquo Workaround 2 Edit the quick filter names to match the original comment values For example if you have entered ldquoQF1rdquo as a quick filter name and ldquoIPAM Utilizationrdquo as the report comment change the quick filter name to ldquoIPAM Utilizationrdquo

                                    NIOS-37415 Users cannot execute Trinzic Automation Engine (TAE) if they log out of NetMRI during an active NetMRI session

                                    NIOS-33600 There is an issue with SafeNet HSMs in that configuration changes do not immediately take effect such as when adding a new member to an existing SafeNet HSM Group deleting a client from the HSM or making member changes You can perform a forced restart of services to apply the changes immediately

                                    NIOS-31864 Modifying a zone from a client increments the zonersquos serial number even if the zone contents did not change This causes unnecessary AXFRs to secondary servers and if the zone is served by a Microsoft Server that is managed in read-write mode it causes extra synchronizations as well

                                    NIOS 701 Release Notes

                                    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 20 of 21 400-0579-001 Rev A 1212015

                                    NIOS-31501 When a Microsoft server is the primary server for a zone and another Microsoft server is hosting the same zone as a stub zone and the NIOS appliance synchronizes DNS data with only one of these zones it will synchronize the zone as an authoritative or stub zone depending on which Microsoft server it synchronizes with first For more information please refer to KB article 17593

                                    NIOS-25064 (45488)

                                    If you configured a member DHCP server to authenticate DHCP clients with a RADIUS authentication server group and RADIUS is disabled (the server group is disabled all RADIUS servers in the group are disabled or the member DHCP server was not assigned an authentication server group) NAC filters with ldquodoes not equalrdquo rules will always match Workaround Do not disable RADIUS

                                    NIOS-21512 (39917)

                                    When you stop the DNS service of an independent appliance with temporary DNS and DHCP licenses Grid Manager displays the Restart Services panel regardless of which function you select

                                    NIOS-21499 (38968)

                                    An admin cannot display DNS views created by other admins during the same browser session To display the DNS views created by other admins you must log out and log in again

                                    NIOS-19853 (31668)

                                    Grid Manager does not display an error when you move a DNS view to a network view that contains a host record that has the same MAC address as a host record in the DNS view that is being moved

                                    NIOS-19144 (30208)

                                    Grid Manager does not sort columns correctly in the IPAM and Network list panels when the columns contain UTF-8 data

                                    NIOS-18163 (27831)

                                    The appliance allows users with read-only permission to A records to view DNSSEC resource records as well

                                    NIOS-17636 (26233)

                                    Syslog messages generated during a TFTP file transfer display the incorrect time zone

                                    NIOS-17513 (26080)

                                    Adding updating or deleting reverse zones could fail due to unsupported PTR records in the root zone

                                    PAPIPASS-39

                                    When you use Mozilla Firefox 16x 17x or Mozilla Firefox Beta 180b3 browser the hidden password in the Add Administrator Wizard of Grid Manager may disappear when you click the Password field after you have confirmed the password This is a known issue when you use Firefox browsers

                                    MME-154 When a NIOS user deletes a Microsoft AD domainrsquos primary zones and subzones NIOS should display a more specific message warning users about the consequences of the operation instead of the general warning message it currently displays

                                    MME-129 When a Microsoft admin creates a delegation on the Microsoft server and the delegation is synchronized to the NIOS appliance the glue A record of the delegation name server is synchronized to the appliance as a manually created record If on the NIOS appliance an admin changes the IP address on the NS record of the delegation name server two A glue records are generated one with the original address one with the new address NIOS retains the original glue A record because itrsquos marked as a manually created record and it can only be changed or deleted either manually on Grid Manager or through the API When synchronization occurs the Microsoft server correctly updates the existing glue A record and does not retain the original Note that NIOS retains the original A record only after the initial update If you update the A record again NIOS just updates the existing record without retaining the original

                                    MME-23 NIOS displays an ldquoInternal Errorrdquo message when you try to apply a quick filter for a range that equals 1 when you display a range in the IPv4 Microsoft Superscopes tab

                                    MME-6 If you add a hostname to the Target field of an SRV record on Grid Manager when the member synchronizes the SRV record to a Microsoft server it adds a new SRV record with the hostname instead of modifying the existing record

                                    NIOS 701 Release Notes

                                    copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 21 of 21 400-0579-001 Rev A 1212015

                                    MSSS-11 (45296)

                                    When you run a discovery on a network served by Microsoft servers and Grid Manager discovers a MAC address that does not match any of the fixed addresses associated with an IP address it reports a conflict and lists the associated fixed address objects in the Related Objects table You cannot select which fixed address to resolve in the Related Objects table You can only resolve the conflict for the first address

                                    VNIOS-36 (41215)

                                    If a virtual NIOS member does not start up due to a license violation Grid Manager displays the status of the vNIOS member as ldquoonlinerunningrdquo even though the member is not online

                                    • INTRODUCTION
                                      • Supported Platforms
                                        • NEW FEATURES
                                          • NIOS 700
                                            • CHANGES TO DEFAULT BEHAVIOR
                                              • NIOS 700
                                              • NIOS 6x Releases
                                                • CHANGES TO Infoblox API and RESTful API
                                                  • RESTful API Deprecation and Backward Compatibility Policy
                                                  • NIOS 70x
                                                  • NIOS 6x Releases
                                                    • UPGRADE GUIDELINES
                                                      • Upgrading to NIOS 70x
                                                        • BEFORE YOU INSTALL
                                                        • ACCESSING GRID MANAGER
                                                        • ADDRESSED VULNERABILITIES
                                                        • RESOLVED ISSUES
                                                          • Fixed in 701
                                                          • Fixed in 700
                                                            • KNOWN GENERAL ISSUES

                                      NIOS 701 Release Notes

                                      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 19 of 21 400-0579-001 Rev A 1212015

                                      VLAN-324 If you have assigned multiple VLANs to the LAN1 or LAN2 interfaces on the appliance you may receive messages about having ldquomultiple interfaces that match the same subnetrdquo during dhcpd process startups or restarts Note that these are not error messages and no actions are required

                                      NIOS-44055 If you use certain versions of Mozilla FireFox to run Grid Manager the auto-detected time zone feature may not function properly even if you have enabled it in your User Profile

                                      NIOS-43957 When you upgrade from NIOS 66x or earlier releases the email address in the SOA resource record that was entered in punycode will be converted into IDN (Internationalized Domain Name) after the upgrade Workaround Convert the IDN back to punycode using the IDN converter utility through Grid Manager

                                      NIOS-43569 You may not be able to view reverse-mapping zones in an internal DNS view Workaround Set the table size to 10 in User Profile log out and then log back in to the system again

                                      NIOS-41136 Reporting When you use certain versions of Mozilla Firefox and Google Chrome browsers on Windows 7 or Linux you may not be able to properly print reports

                                      NIOS-39922 On Trinzic 2200 series appliances it may take up to three minutes for the LOM (Light On Management) LED to stop blinking after you have disabled the LOM feature

                                      NIOS-38870 When you change the member type of an appliance from Infoblox to vNIOS the appliance might display an error message indicating that all network port settings of the vNIOS member must be changed to Automatic Workaround Through the Infoblox API use InfobloxGridMember and the functions lan_port_duplex( ) and lan_port_speed ( ) to change the network port settings for the vNIOS member

                                      NIOS-38579 Reporting If you have a quick filter that includes a filter criterion with report comment equals to a value that NIOS automatically translates to another value the quick filter may not function properly after an upgrade to NIOS 65 or 66 NIOS automatically translates the following ldquoIPAM Utilizationrdquo to ldquoDDI Utilizationrdquo ldquoDNS Zone Statistics per DNS Viewrdquo to ldquoDNS Statistics per DNS Viewrdquo ldquoDNS Zone Statistics per DNS Zonerdquo to ldquoDNS Statistics per Zonerdquo ldquoDNS Member QPS Trendrdquo to ldquoDNS Query Rate by Serverrdquo and ldquoDNS Queries per Second Trendrdquo to ldquoDNS Query Rate by Query Typerdquo Workaround 1 Edit the original report comment values to match the translated values For example if you have entered ldquoIPAM Utilizationrdquo in the comment field of a report change it to ldquoDDI Utilizationrdquo Workaround 2 Edit the quick filter names to match the original comment values For example if you have entered ldquoQF1rdquo as a quick filter name and ldquoIPAM Utilizationrdquo as the report comment change the quick filter name to ldquoIPAM Utilizationrdquo

                                      NIOS-37415 Users cannot execute Trinzic Automation Engine (TAE) if they log out of NetMRI during an active NetMRI session

                                      NIOS-33600 There is an issue with SafeNet HSMs in that configuration changes do not immediately take effect such as when adding a new member to an existing SafeNet HSM Group deleting a client from the HSM or making member changes You can perform a forced restart of services to apply the changes immediately

                                      NIOS-31864 Modifying a zone from a client increments the zonersquos serial number even if the zone contents did not change This causes unnecessary AXFRs to secondary servers and if the zone is served by a Microsoft Server that is managed in read-write mode it causes extra synchronizations as well

                                      NIOS 701 Release Notes

                                      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 20 of 21 400-0579-001 Rev A 1212015

                                      NIOS-31501 When a Microsoft server is the primary server for a zone and another Microsoft server is hosting the same zone as a stub zone and the NIOS appliance synchronizes DNS data with only one of these zones it will synchronize the zone as an authoritative or stub zone depending on which Microsoft server it synchronizes with first For more information please refer to KB article 17593

                                      NIOS-25064 (45488)

                                      If you configured a member DHCP server to authenticate DHCP clients with a RADIUS authentication server group and RADIUS is disabled (the server group is disabled all RADIUS servers in the group are disabled or the member DHCP server was not assigned an authentication server group) NAC filters with ldquodoes not equalrdquo rules will always match Workaround Do not disable RADIUS

                                      NIOS-21512 (39917)

                                      When you stop the DNS service of an independent appliance with temporary DNS and DHCP licenses Grid Manager displays the Restart Services panel regardless of which function you select

                                      NIOS-21499 (38968)

                                      An admin cannot display DNS views created by other admins during the same browser session To display the DNS views created by other admins you must log out and log in again

                                      NIOS-19853 (31668)

                                      Grid Manager does not display an error when you move a DNS view to a network view that contains a host record that has the same MAC address as a host record in the DNS view that is being moved

                                      NIOS-19144 (30208)

                                      Grid Manager does not sort columns correctly in the IPAM and Network list panels when the columns contain UTF-8 data

                                      NIOS-18163 (27831)

                                      The appliance allows users with read-only permission to A records to view DNSSEC resource records as well

                                      NIOS-17636 (26233)

                                      Syslog messages generated during a TFTP file transfer display the incorrect time zone

                                      NIOS-17513 (26080)

                                      Adding updating or deleting reverse zones could fail due to unsupported PTR records in the root zone

                                      PAPIPASS-39

                                      When you use Mozilla Firefox 16x 17x or Mozilla Firefox Beta 180b3 browser the hidden password in the Add Administrator Wizard of Grid Manager may disappear when you click the Password field after you have confirmed the password This is a known issue when you use Firefox browsers

                                      MME-154 When a NIOS user deletes a Microsoft AD domainrsquos primary zones and subzones NIOS should display a more specific message warning users about the consequences of the operation instead of the general warning message it currently displays

                                      MME-129 When a Microsoft admin creates a delegation on the Microsoft server and the delegation is synchronized to the NIOS appliance the glue A record of the delegation name server is synchronized to the appliance as a manually created record If on the NIOS appliance an admin changes the IP address on the NS record of the delegation name server two A glue records are generated one with the original address one with the new address NIOS retains the original glue A record because itrsquos marked as a manually created record and it can only be changed or deleted either manually on Grid Manager or through the API When synchronization occurs the Microsoft server correctly updates the existing glue A record and does not retain the original Note that NIOS retains the original A record only after the initial update If you update the A record again NIOS just updates the existing record without retaining the original

                                      MME-23 NIOS displays an ldquoInternal Errorrdquo message when you try to apply a quick filter for a range that equals 1 when you display a range in the IPv4 Microsoft Superscopes tab

                                      MME-6 If you add a hostname to the Target field of an SRV record on Grid Manager when the member synchronizes the SRV record to a Microsoft server it adds a new SRV record with the hostname instead of modifying the existing record

                                      NIOS 701 Release Notes

                                      copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 21 of 21 400-0579-001 Rev A 1212015

                                      MSSS-11 (45296)

                                      When you run a discovery on a network served by Microsoft servers and Grid Manager discovers a MAC address that does not match any of the fixed addresses associated with an IP address it reports a conflict and lists the associated fixed address objects in the Related Objects table You cannot select which fixed address to resolve in the Related Objects table You can only resolve the conflict for the first address

                                      VNIOS-36 (41215)

                                      If a virtual NIOS member does not start up due to a license violation Grid Manager displays the status of the vNIOS member as ldquoonlinerunningrdquo even though the member is not online

                                      • INTRODUCTION
                                        • Supported Platforms
                                          • NEW FEATURES
                                            • NIOS 700
                                              • CHANGES TO DEFAULT BEHAVIOR
                                                • NIOS 700
                                                • NIOS 6x Releases
                                                  • CHANGES TO Infoblox API and RESTful API
                                                    • RESTful API Deprecation and Backward Compatibility Policy
                                                    • NIOS 70x
                                                    • NIOS 6x Releases
                                                      • UPGRADE GUIDELINES
                                                        • Upgrading to NIOS 70x
                                                          • BEFORE YOU INSTALL
                                                          • ACCESSING GRID MANAGER
                                                          • ADDRESSED VULNERABILITIES
                                                          • RESOLVED ISSUES
                                                            • Fixed in 701
                                                            • Fixed in 700
                                                              • KNOWN GENERAL ISSUES

                                        NIOS 701 Release Notes

                                        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 20 of 21 400-0579-001 Rev A 1212015

                                        NIOS-31501 When a Microsoft server is the primary server for a zone and another Microsoft server is hosting the same zone as a stub zone and the NIOS appliance synchronizes DNS data with only one of these zones it will synchronize the zone as an authoritative or stub zone depending on which Microsoft server it synchronizes with first For more information please refer to KB article 17593

                                        NIOS-25064 (45488)

                                        If you configured a member DHCP server to authenticate DHCP clients with a RADIUS authentication server group and RADIUS is disabled (the server group is disabled all RADIUS servers in the group are disabled or the member DHCP server was not assigned an authentication server group) NAC filters with ldquodoes not equalrdquo rules will always match Workaround Do not disable RADIUS

                                        NIOS-21512 (39917)

                                        When you stop the DNS service of an independent appliance with temporary DNS and DHCP licenses Grid Manager displays the Restart Services panel regardless of which function you select

                                        NIOS-21499 (38968)

                                        An admin cannot display DNS views created by other admins during the same browser session To display the DNS views created by other admins you must log out and log in again

                                        NIOS-19853 (31668)

                                        Grid Manager does not display an error when you move a DNS view to a network view that contains a host record that has the same MAC address as a host record in the DNS view that is being moved

                                        NIOS-19144 (30208)

                                        Grid Manager does not sort columns correctly in the IPAM and Network list panels when the columns contain UTF-8 data

                                        NIOS-18163 (27831)

                                        The appliance allows users with read-only permission to A records to view DNSSEC resource records as well

                                        NIOS-17636 (26233)

                                        Syslog messages generated during a TFTP file transfer display the incorrect time zone

                                        NIOS-17513 (26080)

                                        Adding updating or deleting reverse zones could fail due to unsupported PTR records in the root zone

                                        PAPIPASS-39

                                        When you use Mozilla Firefox 16x 17x or Mozilla Firefox Beta 180b3 browser the hidden password in the Add Administrator Wizard of Grid Manager may disappear when you click the Password field after you have confirmed the password This is a known issue when you use Firefox browsers

                                        MME-154 When a NIOS user deletes a Microsoft AD domainrsquos primary zones and subzones NIOS should display a more specific message warning users about the consequences of the operation instead of the general warning message it currently displays

                                        MME-129 When a Microsoft admin creates a delegation on the Microsoft server and the delegation is synchronized to the NIOS appliance the glue A record of the delegation name server is synchronized to the appliance as a manually created record If on the NIOS appliance an admin changes the IP address on the NS record of the delegation name server two A glue records are generated one with the original address one with the new address NIOS retains the original glue A record because itrsquos marked as a manually created record and it can only be changed or deleted either manually on Grid Manager or through the API When synchronization occurs the Microsoft server correctly updates the existing glue A record and does not retain the original Note that NIOS retains the original A record only after the initial update If you update the A record again NIOS just updates the existing record without retaining the original

                                        MME-23 NIOS displays an ldquoInternal Errorrdquo message when you try to apply a quick filter for a range that equals 1 when you display a range in the IPv4 Microsoft Superscopes tab

                                        MME-6 If you add a hostname to the Target field of an SRV record on Grid Manager when the member synchronizes the SRV record to a Microsoft server it adds a new SRV record with the hostname instead of modifying the existing record

                                        NIOS 701 Release Notes

                                        copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 21 of 21 400-0579-001 Rev A 1212015

                                        MSSS-11 (45296)

                                        When you run a discovery on a network served by Microsoft servers and Grid Manager discovers a MAC address that does not match any of the fixed addresses associated with an IP address it reports a conflict and lists the associated fixed address objects in the Related Objects table You cannot select which fixed address to resolve in the Related Objects table You can only resolve the conflict for the first address

                                        VNIOS-36 (41215)

                                        If a virtual NIOS member does not start up due to a license violation Grid Manager displays the status of the vNIOS member as ldquoonlinerunningrdquo even though the member is not online

                                        • INTRODUCTION
                                          • Supported Platforms
                                            • NEW FEATURES
                                              • NIOS 700
                                                • CHANGES TO DEFAULT BEHAVIOR
                                                  • NIOS 700
                                                  • NIOS 6x Releases
                                                    • CHANGES TO Infoblox API and RESTful API
                                                      • RESTful API Deprecation and Backward Compatibility Policy
                                                      • NIOS 70x
                                                      • NIOS 6x Releases
                                                        • UPGRADE GUIDELINES
                                                          • Upgrading to NIOS 70x
                                                            • BEFORE YOU INSTALL
                                                            • ACCESSING GRID MANAGER
                                                            • ADDRESSED VULNERABILITIES
                                                            • RESOLVED ISSUES
                                                              • Fixed in 701
                                                              • Fixed in 700
                                                                • KNOWN GENERAL ISSUES

                                          NIOS 701 Release Notes

                                          copy 2015 Infoblox Inc All Rights Reserved All registered trademarks are property of their respective owners Page 21 of 21 400-0579-001 Rev A 1212015

                                          MSSS-11 (45296)

                                          When you run a discovery on a network served by Microsoft servers and Grid Manager discovers a MAC address that does not match any of the fixed addresses associated with an IP address it reports a conflict and lists the associated fixed address objects in the Related Objects table You cannot select which fixed address to resolve in the Related Objects table You can only resolve the conflict for the first address

                                          VNIOS-36 (41215)

                                          If a virtual NIOS member does not start up due to a license violation Grid Manager displays the status of the vNIOS member as ldquoonlinerunningrdquo even though the member is not online

                                          • INTRODUCTION
                                            • Supported Platforms
                                              • NEW FEATURES
                                                • NIOS 700
                                                  • CHANGES TO DEFAULT BEHAVIOR
                                                    • NIOS 700
                                                    • NIOS 6x Releases
                                                      • CHANGES TO Infoblox API and RESTful API
                                                        • RESTful API Deprecation and Backward Compatibility Policy
                                                        • NIOS 70x
                                                        • NIOS 6x Releases
                                                          • UPGRADE GUIDELINES
                                                            • Upgrading to NIOS 70x
                                                              • BEFORE YOU INSTALL
                                                              • ACCESSING GRID MANAGER
                                                              • ADDRESSED VULNERABILITIES
                                                              • RESOLVED ISSUES
                                                                • Fixed in 701
                                                                • Fixed in 700
                                                                  • KNOWN GENERAL ISSUES

                                            top related