MODERNIZATIONS Power Unit NGV-EK Range

02C13ENG006

The NGV-EK Power Units have been designed to upgrade existing hydraulic elevators with mechanical valves. You can install the latest technology of Electronic Valves NGV-EK in a fast and easy way, without making any changes to the control panel.

ADVANTAGES FOR LIFT COMPANY

• Fast and easy modernization of existing installation, with no costs for changing control panels.

• Offering a quick and economical solution to the customer.• Reduced cost of maintenance and service.• GMV Warranty.• Adjustable inspection speed, increasing security during maintenance

works.• Produces a customized study to reduce consumption and contracted

power.

USER ADVANTAGES

• Improved comfort during the start, running and stop phases.

• Improved stopping by using NGV-EK Valves.• Increasing SPH (starting per hour).• Integrates dual security system according to EN 81.2-A3.• Reduced energy consumption of lifts up to 40% depending on installation,

thanks to DRY motors, which leads to a reduction of contracted power and electricity cost.

TECHNOLOGY DRY-GMV

Important note: the replacement of a power unit installed under Directive 95/16/EC - 81.2 with the new NGV-EK Power Unit does not require an amendment of the control panel and any additional adjustment for EN 81.2-A3.In case of substantial changes to the installation which requires an adaptation to EN81.2-A3, GMV can provide the product according to Annex A3.

For any questions, please contact our sales department.

POWER UNIT NGV-EK RANGE

SPEE

D

0

5

10

15

20

25

5,57 ,5 9,2

CU

RR

ENT

RA

TIN

G (

A)

DR

Y G

MV

DR

Y G

MV

DR

Y G

MV

HYDRAULIC DRIVE POWER (kW)

© 2013 GMV Eurolift. The information provided in this document is subject to change without notice.2/4

MODERNIZATIONS Power Unit NGV-EK Range

VALVES GROUP NGV-EK CHARACTERISTICS

ELECTRONIC CHARACTERISTICS

TECHNICAL SPECIFICATION

Type NGV-EK - 1” 1/4

RegulationsEN 81.2 -/ EN 81.70Double safety system

Technology FLUITRONIC - Stepping System

Flow Range L/Min 55 ÷ 300 [l/min]

Maximum car speed 1 [m/s]

Maximum static pressure (full load) 45 / 4.5 [bar/MPa]

Minimum static pressure (no load) 12 / 1,2 [bar/MPa]

Flow < 250 l/min ≥ 250 l/min

Valves exit 1” 1/4 1” 1/2

Departure orientation G.V. vertical / Horizontal Horizontal

Flexible hose- 1” 1/4

stiff pipe - 35 L

Flexible hose 1” 1/2

stiff pipe42 L

Operating temperature 5 ÷ 70 ºC

Fluid type Ecological / Mineral ISO VG 46(1)

(1) Fluid recommended ensures optimal performance of the equipment.

TECHNICAL SPECIFICATIONS

Type NGV EK 01

Technology Digital fluitronic- Stepping System

Regulations EMC EN 12015 y EN 12016

Stand-by consumption 3 W

Maximum consumption 25 W

Supply voltage for electronic board 24 Vdc -5% +20% (2)

Input signals 3010 / 3010-VMP / 3010 - 2CH

Supply voltage for input signals24 ÷ 60 Vdc/AC ±10 %80 ÷ 180 Vdc ±10 %

230 Vac ±10 %

Electrical emergency lowering coil voltage (2)

12 Vdc - 2,-2 A

Location Enclosure installed on power unit(3)

Outputs to control panel3 Programmable relay outputs(minimum / maximum pressure and overload (NO/NC)

1 Fault relay output (NO/NC)

Relay outputs characteristics 2A@250Vac

Indicators LEDs status

Optional accessories Programmer / MicroSD Card

(2) ALM03 power supply is provided for powering the control board.

(3) The electronic board supplied is installed on the power unit and pre-wired toward the valves.

© 2013 GMV Eurolift. The information provided in this document is subject to change without notice.3/4

MODERNIZATIONS Power Unit NGV-EK Range

OPTIONAL ACCESSORIES

Electrical Emergency Downward 12 Vdc PT-01

NGV-EK range is made up of the following models of power unit:

MODELGL F1 GL DRY F1 DRY T2 T3(*)

Motor type SUBMERGED SUBMERGED DRY DRY SUBMERGED SUBMERGED

Frequency [Hz] 50 - 60

Motor power [KW] 2,2 ÷14.7 2,2 ÷ 14,7 2,2 ÷ 9,2 2,2 ÷ 9,2 2,2 ÷ 22 11 ÷ 29,4

Motor power [CV] 3,0 ÷ 20 3,0 ÷ 20 3,0 ÷ 12,5 3,0 ÷ 12,5 3,0 ÷ 25 3,0 ÷ 40

Rated pump flow[l/min] 55 ÷ 210 55 ÷ 210 55 ÷ 150 55 ÷ 150 55 ÷ 216 55 ÷ 300

Maximum weight [kg] 90 100 90 100 180 270

Circulating Oil [l] 75 90 75 90 150 300

Minimum Oil [l] 45 40 15 20 70 100

Total capacity [l] 120 120 90 110 220 400

(*) The power unit Type 3 is available up to 300 l/min - for higher flows contact the sales department

The power unit NGV-EK range includes as standard::• Power unit with NGV-EK (1”1/4) valve with pulsation damper• Inspection Gauge fitting according to EN 81.2• Oil temperature sensor 70 °C• Motor terminals box• Electronic board 24 Vdc with 4 outputs (3 programmables) • Shut-off valve 1” 1/4• Power supply ALM 03 - 20-230 Vac/dc• MP-ISO device for direct start• Hand pump

POWER UNITS RANGE

© 2013 GMV Eurolift. The information provided in this document is subject to change without notice.4/4

MODERNIZATIONS Power Unit NGV-EK Range

BOX NGV-EK connections box / control panelC1 VRP Chamber

C2 Inlet chamber

C3 VB Discharge chamber

C4 OS spool chamber

CARD NGV-EK control boardDAL Micro-levelingDN DownwardFLT FilterISP Inspection gauge fitting EN 81.2J JackK One-way valveM, Ma MotorM1 VRP spool

MAN Pressure gauge

ML Manual lowering buttonMP Motor - pumpMPS Pressure relief spoolNGV-EK NGV-EK Valves P OS spoolPAM Hand pumpPT Pressure transducerSM Stepping systemTO Thermostat oilTT Temperature transducerVB Flow adjustment main valveVBP By-pass valveVC Rupture valveVMD Downward solenoid valveVR One-way valve (flow)

VR1 One-way valve (inlet)VR2 One-way valve (outlet)VRP One-way valve - controlledVS1, VS10

Pressure relief valve

VSMA Valve manual / electrical

1 Regulator of the pressure safety valve (pressure limiter)10 Regulator of the pressure safety valve (hand pump)7 Regulator of the ram pressure (only 2:1 acting jacks)6 Pressure gauge shut-off valve5 Rupture valve test screw