METAL PRODUCTS Easy-Lock™ Installation Guide · pleasing appearance. ! 12ý and 16ý coverage options ¥ 12ý and 16ý coverage options 1ý to 1½ý vertical rib ¥ 12ý and 16ý
Post on 20-Jun-2020
1 Views
Preview:
Transcript
Easy-Lock™ Installation Guide
TAYLORM E T A L P R O D U C T S
TAYLORM E T A L P R O D U C T S
Panel Specifications ............................Introduction ............................................Handling and Storage ............................Taylor Delivery Fleet ..............................Delivery & Will Call/Loading ..................Tools & Equipment .................................Fasteners ...............................................Roof Preparation ...................................Roof Layout .....................................Reversing Strip .....................................Panel Preparation ................................Panel Installation ..................................Flashing Details ............................... Inside Gable Application .................Skylight/Chimney Application .......... Pipe Penetration Applications .........Standard Flashing Selections .........
FLASHINGS Low Pitch Eave Detail ...........................Hook Eave Detail ..................................Hook Eave with Gutter Detail ...............Hip / Ridge Detail ................................. Wide Ridge Detail .................................Valley - High Pitch Detail ...................... Valley - Low Pitch Detail .......................Box Gable Detail ..................................Prow Detail ...........................................Sidewall Detail ....................................Peak Flashing Detail (R.E.C.) ..............Pitch Change Detail ............................. Hemmed Endwall Detail .......................Vented Endwall Detail ..........................End Dam Detail ....................................
Table of Contents
1-23 4 5 6 78.9
10-1112 1314
15-2930-3233-3536-3940-45
15161718192021 2223242526272829
HIP/RIDGE CAP
VALLEY
GABLE
EAVE
PITCH CHANGE
END WALL
C-CASING
SIDE WALL
PIPEPENETRATION
HIP
1
STRIATIONS
ACCENT RIBS 3 Accent ribs for 12" panel4 Accent ribs for 16" & 18" panel
PANEL PROFILES
12", 16" and 18" coverage options
LOCK SEAM DETAL REVERSE LAP DETAIL
TAYLORM E T A L P R O D U C T S
Easy-Lock™STANDING SEAM
• 12", 16" and 18" coverage options
• 26, 24 & 22 gauge Tru-Gauge™ and .032" Aluminum • 16 & 20 oz. Copper (Please inquire)
• Factory-notched panels available
• Vertical interlocking application: allows installation from both directions starting at any location
• Patented no-siphon lock seam
• 1-1/8" vertical rib with 3/8" flat top for ease of flashing attachment
• Concealed fasteners: fasteners cannot leak
• Pre-slotted fastener flange: allows expansion / contraction of panel
• - Code compliance UL Evaluation Report UL ER 25913-01
• UL 580 Class 90 Wind Uplift rated, UL 790 Class A Fire rated and UL 2218 Class 4 Impact (hail) rated
• UL Construction No. 529
• 3:12 minimum pitch recommended (For lower pitches, please inquire)
• Standard panel lengths 4' to 35' - not notched Standard panel lengths 1' to 35' - notched (For longer lengths, please inquire)
• Panel options: Striations, Accent Ribs, and Flat Pan
KEY FEATURES
Premier-Lock™ STANDING SEAM
Key Features
architecturally pleasing appearance.
Factory-notched panels
• Prevents crowning• No visible screws required• Sharp, professional appearance
12˝,%16˝%and%18˝%coverage
!! Classic Lock™ STANDING SEAM
!!! !
1ý Classic Lock 100
1½ý Classic Lock 150
The Classic-Lockª Standing Seam is the only metal roofing panel with non-siphon dry lock seam. The panel is designed with softer, less industrial lines to provide a more architecturally pleasing appearance.
!
12ý and 16ý coverage options
¥ 12ý and 16ý coverage options
1ý to 1½ý vertical rib
¥ 12ý and 16ý coverage options ¥ 24 and 26 Tru-Gaugeª ¥ Factory-notched panels available ¥ Prevents crowning ¥ No visble screw required ¥ Sharp, professional apperance ¥ Patented no-sihon lock seam ¥ 1ý to 1½ý vertical rib ¥ Conceled fasteners ¥ Pre-slotted fastener ßange: prevents leakage and allows for expansion/contraction of panel ¥ UL580 Class 90 wind uplift ¥ UL Class A Þre rated ¥ 3:12 minimum pitch recommended: for longer panels, please inquire
12ý and 16ý coverage options
!
Classic Lock™ STANDING SEAM
!!! !
!
Classic Lock™ STANDING SEAM
1ý Classic Lock 100
1½ý Classic Lock 150
!
The Premier-Lock™ Standing Seam has the anti-capillary dry lock seam. It's designed with softer, less industrial lines to provide a more architecturally pleasing appearance.
¥ 12ý, 16ý and 20ý coverage options ¥ 24 and 26 Tru-Gaugeª ¥ Factory-notched panels available ¥ Anti-Capillary dry lock seam ¥ 1ý and 1½ý vertical rib ¥ Concealed fasteners ¥ Pre-slotted fastener ßange: allows expansion/contraction of panel ¥ UL580 Class 90 wind uplift ¥ UL Class A Þre rated ¥ 3:12 minimum pitch recommended: for lower pitches please inquire ¥ Standard panel lengths 2' to 35': for longer panels, please inquire ¥ Pan options: Flat pan, Accent ribs, Striations
12ý, 16ý and 20ý coverage options
1ý Premier-Lock 100 1½ý Premier-Lock 150
5711 Perrin Ave • McClellan, CA 95652 • 916.318.8844• TAYLORMETAL.COM
The Easy-Lock™ Standing Seam is the only metal roofing panel with a patented no-siphon dry lock seam, with a unique reversing feature to allow installation of panels from both directions starting at any location. The panel is designed with softer, less industrial lines to provide an architecturally pleasing appearance.
2
These printed chips provide a close representation of the colors. Metal samples are available upon request. Coatings are low gloss 10-15% sheen.SRI = Solar Reflective Index. SRI values listed above are in accordance with ASTM E 1980 and are based on actual testing.***Oil canning is not a cause for material rejection***
1-20
Kynar 500
Commercial-grade metal primer
G-90 galvanizing
24 or 26 guage steel
G-90 galvanizing
Commercial-grade metal primer
Corrosion resistant primer
Kynar 500® paint layer
Commercial-grade metal primerG-90 Galvanized or AZ-50
Base SteelG-90 Galvanized or AZ-50Commercial-grade metal primerCorrosion resistant wash coat
STANDARD COOL KYNAR 500® COLORS
MATERIAL SPECIFICATIONS• 26 gauge Kynar 500® Painted Steel .019" (thickness prior to painting) G-90 Galvanized or AZ-50
• 24 gauge Kynar 500® Painted Steel .0236" (thickness prior to painting) G-90 Galvanized or AZ-50
• 24 & 22 gauge Zincalume® Plus, AZ-55 (No finish warranty – 25 yr. perforation warranty)
• 22 gauge Kynar 500® Painted Steel .029" (thickness prior to painting) G-90 Galvanized or AZ-50
• .032" Kynar 500® Painted Aluminum
• 22 gauge Rusteel Plus™ (A606)
• 16 and 20 oz. Copper (Please inquire)
• Kynar 500® and substrate testing data available (See website)
KEY FEATURES• 21 Standard Colors, 5 Metallic Colors and 4 Specialized Colors
• Kynar 500® Paint System - the ultimate in exterior durability and color retention
• “Cool” color pigments are specially designed to reflect infrared light, reducing heat gain to dwelling, and conform with ENERGY STAR® criteria
• Superior quality, two coat, 70% resin finish, applied at a 1mm thickness
• 40 year residential paint warranty
• 20 and 30 year commercial paint warranty: Contact TMP for warranty specifications
40-Year Residential / 20 and 30 Year Commercial Manufacturer’s Limited Warranty
✦
Width Gauge Color LBS SQFT LBS LF12" 26 1 1.13 1.1312" 24 2 1.33 1.3316" 24 3 1.24 1.6518" 24 4 1.21 1.8216" .032 Aluminum 0.58 0.7816" 22 2.07 2.75
Standard Panels
✦
Gla
cier
Whi
te S
RI-8
5
Sier
ra T
an S
RI-6
0
Parc
hmen
t SR
I-58
Ster
ling
Gre
y SR
I-44
Zinc
Gre
y SR
I-39
Cha
rcoa
l Gre
y SR
I-25
Sadd
le T
an S
RI-3
7
Med
ium
Bro
nze
SRI-3
6
Mus
ket S
RI-3
1
Dar
k Br
onze
SR
I-27
Taho
e Bl
ue S
RI-3
1
Paci
fic B
lue
SRI-2
6
Hem
lock
Gre
en S
RI-3
6
Fore
st G
reen
SR
I-24
Pine
Gre
en S
RI-2
5
Burg
undy
SR
I-25
Terra
Cot
ta S
RI-4
3
Tile
Red
SR
I-35
Col
onia
l Red
SR
I-37
Blac
k SR
I-26
Met
allic
Silv
er S
RI-6
0
Cha
mpa
gne
SRI-4
8
Antiq
ue P
atin
a SR
I-40
Cop
per P
enny
SR
I-50
Wea
ther
ed Z
inc
SRI-3
9
16 o
z. a
nd 2
0 oz
. Cop
per
*ple
ase
inqu
ire*
Zinc
alum
e® P
lus
SRI-6
5
Rus
teel
Plu
s™ (A
606)
Rus
teel
Plu
s™ h
as n
o m
etal
lic
coat
ing,
is u
npai
nted
and
has
no w
arra
nty
PREMIUM METALLIC COOL KYNAR® COLORS SPECIALIZED MATERIAL
✦ ✦ ✦ ✦ ✦
✦
Ret
ro R
ed S
RI-4
2
1,2,3,4 1,3,4 2,4 1,3,4 1,2,3,4 1,2,3,4 1,3,4 1,2,3,4 3,4 1,2,3,4 1,2,3,4
1,2,4 2,3,4 1,3,4 1,2,3,4 1,2,3,4 1 3,4 1,3,4 1,4 4
3,4 3 3 3,4 1,2,3,4 2,3,42,3,4 2,3,4
Vint
age®
SR
I-19
Vint
age®
has
a c
olor
rang
e th
at
can
vary
from
bat
ch-to
-bat
ch.
See
TMP
web
site
for m
ore
info
RIVERSIDE CA • SACRAMENTO CA • SALEM OR • SEATTLE WA • WOODINVILLE WA • WWW.TAYLORMETAL.COM
3
Taylor Metal Products, Easy-Lock™ Standing Seam roofing product is designed for residential and light commercial applications, however it is not limited to these uses.
The Easy-Lock™ Standing Seam concealed fastener roofing system is an architectural roofing system and is designed to be weather tight, attractive, easy to install and to provide long life.
These installation instructions are intended to offer suggested application procedures for common building construction. No attempt is made to provide installation details for every application or possible use.
Please contact Taylor Metal Products for use of custom flashing details as they pertain to specific conditions or to discuss a specific project.
Conformity to local building codes, details for specific applications, and use of safety and health procedures is the sole responsibility of the installer.
Taylor Metal Products, assumes no liability for the improper installation of the Easy-Lock™ panel nor for any personal injury or property damage that may occur with the product’s use.
Introduction TAYLORM E T A L P R O D U C T S
*Oil Canning - All light gauge metals can display waviness often referred to as “oil canning." This is caused by steel mill tolerances, substrate variation and relative reflectivity. “Oil canning" is an inherent characteristic of steel products, not a defect, and is not a cause for material rejection.
Easy-Lock Installation Guide - 2020
4
TAYLORM E T A L P R O D U C T S
Handling and StorageStorageStore the panels, flashings, and accessories in a dry, well ventilated area, on level ground. Slightly elevate one end of bundles to allow drainage of wet materials. Support panels with blocks thoughout escalation in elevation to prevent permanent deformation. If covering, allow ventilation around the panels.
Protect panels against standing water and condensation between adjacent surfaces. If panels become wet, immediately separate sheets, wipe dry with clean cloth, and keep sheets separate for air-drying.
Painted metal roofing panels will have a clear plastic film applied to the lower rib of the panel to protect the seam during transportation and handling. Flashing and flat sheet may have a plastic film for protection. Remove this film prior to installation of the panels.
Products with film should not be stored in direct sunlight or under other UV source, and should not be left in extreme heat or cold for long periods.
Secure materials on the ground or roof to prevent winds from moving the materials, especially when leaving the site. Wind-blown materials may cause damage to the material, property or persons. Avoid installing panels in windy conditions.
Safety considerations are the responsibility of the installer and their crew. Be sure to use common sense and accepted industry standard safety practices when installing roofing materials. Always use proper safety equipment and attire to minimize risk of cuts or other injuries.
HandlingHandle materials with care when off loading or moving materials to avoid damage to panels or flashings. Long panels may require two or more pick-up points, properly spaced to avoid damaging panels. Plan ahead. Contact Taylor Metal Products for recommendations on handling/hoisting long panels.
Wear clean cotton gloves when handling copper or unpainted Zincalume® to avoid leaving fingerprints and smudges. While finger-prints or smudges will not harm the material, they will temporarily leave markings on the material until the material weathers.
Wear clean, soft-soled shoes when walking on roofing panels to avoid damage to the painted finish. Take care that sand, gravel, dirt etc. sticking to your shoes is not carried onto the roof, scratching or otherwise damaging the finish on the roofing material.
Walking on asphalt impregnated felt paper, especially on a hot day, can cause the asphalt to stick to your shoes and be tracked onto the roofing material. Do not walk on major ribs of panels. Do not walk on panels that have not been completely installed.
Take care when painting to avoid getting over spray on the roofing material. Remember that wind can carry paint particles some distance. Over spray can cause the finish of the roofing material to look dull and may void your warranty.
Do not allow panels to contact preservative- treated lumber. Water and ice shield material is effective in preventing a corrosive reaction between steel products and pressure-treated lumber.
Easy-Lock Installation Guide - 2020
5
TAYLORM E T A L P R O D U C T S
Taylor Delivery FleetDelivery FleetTaylor Metal Products prides itself with quick lead times delivered with our fleet of semi trucks. Our fleet of trucks are owned and operated by TMP. All of our drivers are Taylor Metal Products employees, so when your truck rolls in to deliver, you are dealing with Taylor Metal Products. Expect consistant and exceptional service with short lead times. The inhouse fleet allows for efficient and cost-effective delivery.
Mounted on the rear of our semitrailer, the trailer-mounted "piggy-back" forklift will accompany you right to your place of use, opening up unprecedented possibilities in terms of transportation. It can travel sideways, carrying panels up to 40' long, allowing delivery in locations that would typically be considered impossible to reach.Save time and effort while avoiding potential loading and transport issues; have experienced TMP personnel deliver and unload your order.
Easy-Lock Installation Guide - 2020
6
Will Call/LoadingFlatbed trailers and trucks are best suited to transport metal roofing materials. These can be loaded from the side with a forklift and tied down in a safe and secure manner.
We are not able to load materials onto vehicles and/or trailers which are not suitable or may be hazardous to load. Please be aware that if we find a vehicle to be inappropriate, we reserve the right to refuse to load your order.
Unacceptable examples include: boat trailers, vans, buses, motor homes, campers and box trailers. Pickup racks which do not have sufficient supports for the weight or are not long enough to support bundles are also unacceptable.
Taylor Metal Products is not responsible to tie down loads nor do we provide any tie down materials. Please bring tie downs to secure your load (string or twine are not acceptable for this purpose).
Consider having your order delivered on one of our trucks with a piggy back forklift.
DeliveryWe will make every attempt to deliver material to the desired location. We may be unable to gain access on tight corners or steep terrain. If the site is deemed inaccessible by our driver, the customer may choose an alternate delivery site within a reasonable proximity. If we are unable to make the alternate delivery, additional charges may be assessed.
The customer is responsible for:• Determining adequate access for delivery
ahead of time.• Meeting the delivery at the agreed upon
time.• Providing adequate resources (1-4 people
as needed) for off loading materials. A charge of $100 per hour may be added for deliveries that go beyond their allotted time.
• Checking the shipment at the time of delivery.
• Verifying material quantities against the shipping/packing list.
• Noting any damage or discrepancies upon the paper work at the time of delivery and notifying Taylor Metal Products within 48 hours of delivery.
Delivery times are usually scheduled one day in advance. Taylor Metal Products will make every effort to make the delivery at the scheduled time. Please be aware that there may be conditions beyond our control such as traffic, mechanical failures, road closures, etc. which may affect our schedule. If a delay is expected, you will be notified in advance of delivery.
Delivery & Will Call/Loading
Easy-Lock Installation Guide - 2020
TAYLORM E T A L P R O D U C T S
7
Tools & Equipment
WARNING : Filings, debris and metal chips must be wiped off panels each day to avoid corroding the panels and causing rust specks or stains. Water can cause non-finished metal shaving to bind to panels after rust develops damaging panels. Failure to properly install panels and remove debris may void the warranty.
The following tools/safety equipment may be used for proper installation:
• Screw Gun: Clutch type, variable torque, cordless screw guns will give the best results.
• Extra batteries
• Bit holder - magnetic
• #2 square drive bits or philips drive bits (for panel screws)
• 1/4" Hex head - magnetic - bit driver (for woodfast flashing screws)
• 1/8" drill bit (for rivets & pre-drilling fastener holes)
• Belt & holster (keeps all the above tools safely on your hip)
Cutting Tools:• Cutters/Offset (curved jaw) left & right (for
precision cutting, long cuts
• Snips (straight jaw) left & right (for short cuts & circular cuts)
• Electric Shears (aids in long panel rips)
CAUTION: POWER SAWS MAY CAUSE PANEL DAMAGE!
TMP recommends cutting panels and flashings with tin snips or shears.
We do NOT recommend the use of saw blades or abrasive wheels - use may void warranties and reduce longevity, especially in marine envirnments.
Other Tools:• DeBurring Tool
• Hole Punch (for pre-punching holes in metal)
• Rubber Mallet - SoftType (for adjusting panels & flashings)
• Quick Square, Framing Square & Bevel Square (aids in squaring flashings & panels)
• Duck Bill Vise Grips/Pliers (for various bending)
• Upender Tools (used for panel-prep, available at TMP)
• Tape Measures
• Rivet Tool (for riveting flashings)
• Marking pen or grease pencil
• Chalk Line (for marking long panel rips and to align panels)
• Protective gloves to protect hands
• Cotton gloves for working with copper (to protect against fingerprints on finish)
• Ear plugs
• Safety harness kit
Easy-Lock Installation Guide - 2020
TAYLORM E T A L P R O D U C T S
8
TAYLORM E T A L P R O D U C T S
FastenersTMP recommends the following fasteners:
FASTENER DESCRIPTION USEPancake Head, Sharp point#10 x 1" #2 Phillips Head
The pancake head screw is recommended for panel attachment and is a concealed fastener.
Waferhead Srew, Sharp point#9-16 x 1" #2 Phillips/Square Drive#9-16 x 1-1/2" #2 Square Drive
Waferhead screws are used for attaching the panels to a wood deck or substrate. They are concealed fasteners.
Lath Head Screw, Sharp Point#8 x 9/16"
While generally not recommended for most applications, this concealed fastener is useful for areas where a longer fastener will penetrate the substrate and exhibit an objectionable appearance, such as exposed overhangs. The pull out rating for this fastener is less than the waferhead, so these fasteners need to be placed more often.
Woodfast Screw, Sharp Point#9-16 x I"1/4" Hex Drive- Color Match #9-16 x 1/2"1/4"
Woodfast screws are recommended for attaching metal to wood in some cases metal to metal.
Stitch Screw, Sharp Point#12 x ¾" ¼" Hex Drive-Color Match
Stitch Screws are used to attach metal to metal such as lap joints in flashing. They can be used interchangeably with rivets.
Rivets#43 (1/8" x 1/8") Stainless Steel rivet Color Matched or non-painted.
Rivets are used to attach metal to metal such as lap joints in flashing.
Easy-Lock Installation Guide - 2020
9
TAYLORM E T A L P R O D U C T S
Roof PreparationNew ConstructionTaylor Metal Products Easy-LockTM Standing Seam roofing products can be installed for either new or re-roofing applications.
We recommend installing the Easy-LockTM Standing Seam over a rigid continuous substrate such as plywood sheathing or decking. We recommend that the plywood be 1/2" or thicker. The product can also be applied over space sheathing at no greater than 24" on center. For best results the substrate should be smooth, flat and free of debris.
Cover the entire roof area with 30 lb. ASTM rated felt paper. Apply the felt by rolling it out horizontally across the roof starting at the eave. Allow a 3" overlap for each course.
Lap end joints 6". Maintain the rule of keeping uphill courses lapped on top of downhill courses of felt. Tears and cuts should be replaced with new felt or repaired with roofing lap cement.
To prevent bonding between the copper and roofing felt, a layer of smooth building paper or a rosin sized slip sheet should be laid over the felt before installing the copper roofing.
VentilationProper ventilation is necessary for full roof life. Check local codes for venting requirements.
To provide for ridge and/or hip ventilation, remove (for retrofit) or leave out (for new construction) 2" of sheathing on both sides of the ridge center. Cover opening with flyscreen and secure the flyscreen with staples. Apply felt paper up to the edge of opening as explained in “Underlayment" section.
Taylor Metal Products recommends allowing ventilation between the outer roof deck and the insulation. Lack of ventilation may trap moisture.The rib of the panel is not a source of ventilation for the area beneath the roofing panels.
Re-Roofing The Easy-LockTM Standing Seam can be installed with felt over most existing asphalt, composition, fiberglass shingles or rolled roofing. Tile, gravel, wood shingles/shake,metal or any other type of roofing material should be removed to the bare sheathing. Inspect the substrate for damage or rot and replace sheathing as necessary. Apply the underlayment as described above.
Consider the following when installing the metal roofing over existing roofing materials:
• Building Codes: Local building codes will typically limit the number of layers of roofing allowed. Check with your agency.
• Solid Fastening: Check the condition of the substrate. Damaged or rotted plywood or decking will not provide for secure fastening. Repair or replace damaged or rotted substrates.
• Appearance: Irregular substrates may affect the overall appearance of the metal roofing product. Panel deformation may occur, however, product integrity will not be affected.
• Roof surface: Any warped or loose shingles must be nailed down along with any protruding nail heads. Remove all moss and other debris, including existing starter strips. Cut off all overhanging shingles and remove hip and ridge caps.
• Ventilation: Trapped moisture can cause premature failure of the metal roofing product as well as substrate, insulation etc. Provide adequate ventilation and appropriate moisture protection.
InsulationCheck with your design professional or insulation consultant for applications or design details. Also check local building codes to ensure compliance.
Touch-Up PaintMost of the time touch-up paint is supplied in spray cans. Spray cans are useful for painting large areas such as downspouts, pipe flashings, and other pre-existing areas.
Scratches and scuffs in the finish should be touched-up but not sprayed. The paint should be well mixed and sprayed into a small container, then applied to scratches with a very fine brush or toothpick,just filling in the scratch. If the area is sprayed over, the differences in the chemical makeup will likely cause the touch-up paint to fade differently than the baked-on finish and cause a blotchy appearance over time.
Paint paint pens are offered in most Kynar® colors and work best for covering minor scratches, please inquire for color options. Paint pens not available for ArmorTech™ panels.
Easy-Lock Installation Guide - 2020
10
TAYLORM E T A L P R O D U C T S
Roof Layout
Method #1: 3-4-5 TriangleThe first method utilizes the 3-4-5 triangle method. After the underlayment has been applied, you must now lay out a grid line along the gable edge to align your first panel. Here we are using a 3-4-5 triangle in increments of 9'-12'-15'(e.g. 3x3=9, 3x4=12, 3x5=15). For longer panels use larger multipliers (5x3=15, 5x4=20, 5x5=25).
Step 1: Snap an alignment line 2 feet from the eave.
Step 2: Start from a point (datum) on the alignment line 1/4" to 1/2" from the left (or right depending on which edge you’re starting from). Establish a 12' arc from datum point.
Step 3: Measure 9 feet from the datum point along the alignment line and establish a reference point there.
Step 4: From the reference point make a 15-foot arc to intersect the 12-foot arc. Snap a chalk line from the intersection point to the datum point. You now have a straight edge to align your first panel along the gable.
Step 5: If you have valleys: Since your underlayment will cover the true center line of your valleys, snap lines at these areas for aligning valley flashings.
It is important to get the roofing panels installed straight and you can’t always depend on the gable/rake edge to be straight. After the underlayment has been applied you must now lay out an alignment line at the gable edge to align your first panel. You can use either of the following methods to check the gable edge to ensure the first panel gets started straight.
Easy-Lock Installation Guide - 2020
11
TAYLORM E T A L P R O D U C T S
Roof Layout
Method #2: Framing SquareThe second method utilizes a framing square. Begin by stretching a string line from corner to corner at the eave edge. After the eave flashings are installed, lay down your first panel and square it at the eave using a framing square along the screw flange edge of the panel and squaring to the string line. Once square, secure alignment panel by putting one panel screw in at the bottom and at the top.
If a gable roof, check for the gable side of the pan to be no more than 3/8" off square. The standard gable flashing will compensate up to 3/8". If more than 3/8", a compensating gable flashing will need to be used.
Another method is to rip the first panel at the correct angle and to up-end the ripped edge 1" at 90 degrees and use the standard gable flashing. It may be required to rip the last panel. For extreme out of square conditions, consider using a Prow Flashing.
Prow RoofsFor a prow roof, use the same procedure above to square the first panel. Go to the top and measure the distance from the prow side of the first full panel to the top of the prow edge. (The prow flashing should be installed first; allow for 2" between the prow pan up-leg and the rib of the first full panel).
For example, if your measurement was 3' - make a pencil mark on the framing square for this measurement.
It is critical to maintain and square with the eave. Snap a chalk line from the top mark to the bottom mark. This will be the actual line you will set your first prow panel on. Also, it will give you the angle required to rip your first, second and third prow panels.
Hip RoofsHip roofs present some challenges to panel alignment. The easiest method of aligning panels on a hip roof is to start in the center of the roof area and use the “Reversing Strip" (see page 13) to install the panels starting at center and installing panels in both directions (left & right).
Use either method of panel alignment to be sure the panels are straight and centered. Position the reversing strip at the center point and fasten into place. Then install the panels as indicated. Incidentally, you can also start the panels at center on a gable roof and work both directions.
Alternately you can align panels on a hip roof by starting with a longer panel (5' to 7') in length. Place the panel in the appropriate spot (usually 5' to 7') from the left or the right and use either method of aligning the panels to get a straight line to work from. Install this panel, and then work back to install the shorter panels and then the rest of the panels as usual.
(a)
Install the first two prow panels and remove the first full-length panel before installing the third prow panel. If you’re accurate on your squaring, cuts and alignment, your first full-length panel will be square to the eave line. (See (a) Dotted line is 2" gap.)
Easy-Lock Installation Guide - 2020
12
TAYLORM E T A L P R O D U C T S
Reversing Strip
Center Line
Step 2: Place a panel of the appropriate length on the roof and hook the lock lip of the panel (located on the upper/female rib) to the lip of the reversing strip. See (b)
Pull the panel so it fits tightly into reversing strip and fasten the panel to the sheathing with waferhead screws.
Step 3: Position the next panel so that the female rib is over the female rib of the previous panel laying the opposite direction. Press down until the panel is locked onto the previous panel. Fasten that panel in place.
Caution: We do not recommend reversing panels on the same pitch when using metallic colors (i.e. weathered zinc or copper penny) or Zincalume®. The paint/coating will reflect differently when the panels are reversed and could look like a different color.
Reversing Strip ApplicationStep 1: Locate the center of the roof section you are working on. Use 3-4-5 Triangle or Framing Square Method. See (a)
Snap a straight line on the mark perpendicular to the eave line. It is important that the line is straight, so that the panels will be straight.
Position the turned edge of the reversing strip along the center-line and fasten to the sheathing every 18" to 24" with a waferhead screw. It won’t matter which direction the strip faces.
Easy-Lock Installation Guide - 2020
*Reversing Strip suitable for use with Easy-Lock & StreamLine™ panels ONLY.
The reversing strip allows the Easy-Lock panels to be installed working both left and right. The reversing strip is most commonly used on hip roof applications although it can be used on other roof styles.
13
TAYLORM E T A L P R O D U C T S
Panel PreparationTop of Panel - UpendTo up-end panels, snip the pan 7/8" beside the female rib, and 7/8" at 1/4" from the inside of the male leg. The up-end tool makes an accurate marking template. After snipping 7/8" cuts, place up-end tool into pan and bend up to just over 90 degrees. The up-end acts as a baffle. The 1/4" gap at the screw flange allows for clearance to snap in the next panel. You will need to fill the gap at each side of the upended panel with flex seal. (Figure 1)
Bottom of PanelSnip off the corner of the fastening flange approximately 45° for appearance. (Figure 2)
For Low Pitch Applications Alternate #1On pitches of less than 3/12, place up-end tool into pan, bend down and under to form an open hem under the pan. This step brings the pan edge below the eave flashing edge which stops any potential wicking or siphoning. (Figure 3)
If using this method, allow for an additional 1/2" of panel length.
Alternate #2On pitches of less than 3/12, use a 1/2" bending tool or other bending tool and make a 30° bend (down) to form a drip edge on the pan of the panel. (Figure 4)
Note: Taylor Metal Products minimum slope recommendation is 3/12 pitch. On projects less than 3/12, contact a Taylor Metal Products sales representative with project specifics.
Easy-Lock Installation Guide - 2020
14
TAYLORM E T A L P R O D U C T S
Panel Installation
First Panel Installation:You may install the panels working from left to right or right to left. It is a matter of choice and convenience. Determine which direction the panels are to be installed before preparing the panel.
Align the upper (female) leg of the panels along the alignment line you made along the gable edge. Allow the panel to overhang at the eave edge 1" to 1-1/4". Apply double row of non-skinning butyl or single row of double bead butyl tape along the eave flashing, position the panel and fasten the panel into place using the waferhead screws. Be certain screw heads are level and flush to the screw flange or they may dent or show through the next panel.
Second and Successive Panels:Apply the bead of caulking on the eave flashing (see Eave Section, page 15) and place panels flush along the eave edge maintaining the overhang established on the first panel.Position the female leg of the next panel over the male leg of the panel previously installed and lock the panels into place using light hand pressure, foot pressure or tap in place with a rubber mallet. Lock the panels from the bottom up. When the rib is locked into place and in the proper position, fasten the panel into place with waferhead screw s.
Repeat for successive panels.
Prior to Panel Installation:
Before you can install the panels you need to install Underlayment (i.e. Felt Paper), Flyscreen, Eave Flashing, Valley Flashing, Prow Gable Flashing, and other flashings as conditions apply.
Consider the following before ordering and/or installing roofing panels or flashing.
The roof area will rarely come out to the even foot. If working on a gable roof and the incremental distance from gable end to gable end is 4" or less (i.e. 48' 4") consider using the compensating gable flashing. This flashing is used to compensate up to 2" on either one or both ends of the roof. The beginning panel can be started 2" in for the edge and end 2" for the opposite edge.
Although to maintain a visually consistent appearance on each gable end, TMP recommends using compensation gable on both ends, rather than standard gable on one end and compensating gable on the other. Using the compensation gable flashing will keep you from having to cut a narrow panel for one end of the roof and will produce a more appealing visual appearance.
Compensating gable flashing is also useful if the roof is out of square and can take up 2" of top to bottom differential.
In the rare case that you should experience difficulty installing a panel due to a factory defect stop immediately and contact Taylor Metal Products. Roof longevity may be compromised and warranty voided by knowingling installing faulty panels. TMP will not be responsible for panels installed with defects. TMP reserves the right to correct the issue before providing replacement panels.
Easy-Lock Installation Guide - 2020
15
Low Pitch Eave TAYLORM E T A L P R O D U C T S
HOOK EAVE
FASCIA BOARD
SHEATHING
UNDERLAYMENT
EASY-LOCK PANEL
NON-SKINNINGGUNNABLE
BUTYL
2" GAPIN BUTYL
#10 SCREW 8" O.C.
4"
1.75"
145°.5" KICK
IF PAINTED,THIS SIDE
90° ORROOF PITCH
#10 SCREW 8" O.C.
LAP UNDERLAYMENTOVER SCREW
DOUBLE ROW OFNON-SKINNING
GUNNABLE BUTYL
9" STRIP OFUNDERLAYMENT
UNDER EAVE
STANDARD EAVE
22 GA OFFSET CLEAT
DOUBLE BEADBUTYL TAPE
EASY-LOCK PANEL
FASCIA
SHEATHINGBEND NOTCHED PANELOVER CLEAT. LEAVE SPACE
FOR PANEL EXPANSIONAND CONTRACTION
Easy LockFlashings and Deatils GuideStandard Eave
LOW PITCH EAVE DETAIL
LOW PITCH EAVE FLASHING(ELELP)
Eave Flashing Application• Install eave flashing prior to panel installation.
(If gutters are installed you may need to notch out for gutter fasteners.) • Use Waferhead Screws and fasten to substrate 18" to 24" or as needed. • Allow 1" to 2" lap and apply sealant to overlap.• Apply 2-1/4" beads of sealant along top of leg of eave flashing, 1" +/- from outside edge.
(You may also use butyl mastic.)• Install fascia leg into gutter.• Insulate between dissimilar metals.
Note: Customize flashing for more or less coverage. Note: If you experience panel crowning, back bend panels at bottom of panel or turn down edge.
HOOK EAVE
FASCIA BOARD
SHEATHING
UNDERLAYMENT
EASY-LOCK PANEL
NON-SKINNINGGUNNABLE
BUTYL
2" GAPIN BUTYL
#10 SCREW 8" O.C.
4"
1.75"
145°.5" KICK
IF PAINTED,THIS SIDE
90° ORROOF PITCH
#10 SCREW 8" O.C.
LAP UNDERLAYMENTOVER SCREW
DOUBLE ROW OFNON-SKINNING
GUNNABLE BUTYL
9" STRIP OFUNDERLAYMENT
UNDER EAVE
STANDARD EAVE
22 GA OFFSET CLEAT
DOUBLE BEADBUTYL TAPE
EASY-LOCK PANEL
FASCIA
SHEATHINGBEND NOTCHED PANELOVER CLEAT. LEAVE SPACE
FOR PANEL EXPANSIONAND CONTRACTION
Easy LockFlashings and Deatils GuideStandard Eave
LOW PITCH EAVE DETAIL
LOW PITCH EAVE FLASHING(ELELP)
Easy-Lock Installation Guide - 2020
16
Hook EaveTAYLORM E T A L P R O D U C T S
2" GAPIN BUTYL
HOOK EAVE
FASCIA BOARD
SHEATHING
UNDERLAYMENT
EASY-LOCK PANEL
NON-SKINNINGGUNNABLE
BUTYL
#10 SCREW 8" O.C.
1.125"
.5" KICK,.5" HEM,
OPEN
IF PAINTED,THIS SIDE
4.375"
1.5"SPECIFYPITCH
145°
HOOK EAVE
#10 SCREW 8" O.C.
LAP UNDERLAYMENT OVER SCREW
DOUBLE ROW OFNON-SKINNING
GUNNABLE BUTYL
9" STRIP OFUNDERLAYMENT
UNDER EAVE
EASY-LOCK PANEL
FASCIA
SHEATHINGBEND NOTCHED PANEL
OVER HOOK. LEAVE SPACEFOR PANEL EXPANSION
AND CONTRACTION
Easy LockFlashing and Details GuideHook Eave
HOOK EAVE DETAIL
HOOK EAVE FLASHING(ELEH)
Easy-Lock Installation Guide - 2020
Hook Eave with Gutter
17
TAYLORM E T A L P R O D U C T S
#10 SCREW 8" O.C.
LAP UNDERLAYMENTOVER SCREW
DOUBLE ROW OFSKINNING GUNNABLE BUTYL
UNDERLAYMENT EAVE
HOOK EAVE
GUTTER HANGER30" O.C.
BOXGUTTER
NEOPRENE WASHEREDSCREW 30" O.C.
GUTTER TAPEREDTO DOWNSPOUT
EASY-LOCK PANEL
FASCIA
SHEATHING
5.5"
4"
3.25"1"
1"
.75"
IF PAINTED,THIS SIDE
12" HEM,
OPEN
2X 108°
6"
HOOK EAVE
FASCIA BOARD
SHEATHING
UNDERLAYMENT
EASY-LOCK PANEL
NON-SKINNINGGUNNABLE
BUTYL
#10 SCREW 8" O.C.
2" GAPIN BUTYL
GUTTER HANGER
BOX GUTTER
1.125"
.5" KICK,.5" HEM,
OPEN
IF PAINTED,THIS SIDE
4.375"
1.5"SPECIFYPITCH
145°
Easy LockFlashing and Details GuideHook Eave With Gutter
GUTTER HOOK EAVE DETAIL BOX GUTTER FLASHING
BOX GUTTER HANGER(AGH6)
HOOK EAVE(ELEH)
Easy-Lock Installation Guide - 2020
18
Hip / RidgeTAYLORM E T A L P R O D U C T S
4" LAP
4"
1" BUTYL SPACING
EASY-LOCKPANEL
HIP / RIDGE
NEOPRENE WASHEREDSCREW OR RIVET
INTO EACH RIB
SHEATHING
UNDERLAYMENT
UPEND PANEL ENDCAULK CORNERS
END DAMDOUBLE BEADBUTYL TAPE
SCREW END DAMTO RIB
SKINNINGGUNNABLEBUTYL
NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIB AND4" O.C. MIN. DRAG LOAD CALCULATIONSMAY REQUIRE MORE.
5.625"
.5" HEM, OPEN
IF PAINTED,THIS SIDE
SPECIFY PITCH
Easy LockFlashing and Details GuideHip / Ridge
HIP / RIDGE DETAIL
HIP / RIDGE FLASHING(ELHR)
HIP / RIDGE LAP
Hip / Ridge Application• Cut standing seam panel to match angle of hip/ridge. • Install panels and upend; caulk the corners.• Notch hip/ridge cap (as required) for ribs on panel(s). Notch with
snips to match rib alignment. • Allow hip/ridge cap to overhang the bottom corner at least 1-1/2".• Box in the lower end to match angle of corner. • Overlap hip/ridge cap, top to bottom, 2" to 3" and caulk each lap. • Attach hip/ridge cap to each rib of panels with woodfast screw, pop
rivet, or stich screw.
Note: If ribs are over 24" apart on panel angles, use "Z" Strip for secure fastening.
4" LAP
4"
1" BUTYL SPACING
EASY-LOCKPANEL
HIP / RIDGE
NEOPRENE WASHEREDSCREW OR RIVET
INTO EACH RIB
SHEATHING
UNDERLAYMENT
UPEND PANEL ENDCAULK CORNERS
END DAMDOUBLE BEADBUTYL TAPE
SCREW END DAMTO RIB
SKINNINGGUNNABLEBUTYL
NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIB AND4" O.C. MIN. DRAG LOAD CALCULATIONSMAY REQUIRE MORE.
5.625"
.5" HEM, OPEN
IF PAINTED,THIS SIDE
SPECIFY PITCH
Easy LockFlashing and Details GuideHip / Ridge
HIP / RIDGE DETAIL
HIP / RIDGE FLASHING(ELHR)
HIP / RIDGE LAP
Easy-Lock Installation Guide - 2020
19
Vented Ridge TAYLORM E T A L P R O D U C T S
4" LAP
4"
1" BUTYL SPACING
SCREW END DAMTO RIB
UPEND PANEL ENDCAULK CORNERS
NOTCH OVERPANEL RIB
VENTED RIDGE
NEOPRENEWASHEREDSCREW OR
RIVET AT 12"O.C. INTO
EACH END DAM.NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIB AND4" O.C. MIN. DRAG LOAD CALCULATIONSMAY REQUIRE MORE.
SHEATHING
DOUBLE BEADBUTYL TAPEON TAB
DOUBLE BEADBUTYL TAPE
6"
SPECIFYPITCH
96°
1" 96°3
4"
IF PAINTED,THIS SIDE
IF PAINTED,THIS SIDE
SPECIFYPITCH
7.125"
1.125"
.5" OPEN HEM
117° TYP. UNLESS NOTED 1.25"
Easy LockEasy Lock Flashings: 10'Vented Ridge
RIDGE LAP
R17 RIDGE FLASHING(ELR17)
RIDGE W/ VENTED CLOSURE DETAIL
FIELD NOTCHED RIDGE FLASHING(ELRS)
Easy-Lock Installation Guide - 2020
20
Valley3:12 or Greater SlopeTAYLOR
M E T A L P R O D U C T S
4"
22 GA. OFFSET CLEAT,SCREWED 8" O.C.
DOUBLE BEADBUTYL TAPE
DOUBLE ROW OFSKINNING GUNNABLE BUTYL
LAP UNDERLAYMENTOVER SCREW
UNDERLAYMENT 1.5"
1"
.5"
155° TYP.
THREE ROWS OFNON-SKINNING
GUNNABLE BUTYLAT LAP JOINT
12"
1"
IF PAINTED,THIS SIDE
11"
SPECIFY PITCH
IF PAINTED,THIS SIDE
1"
15.875"
SPECIFY PITCH
.5" HEM, OPEN
Easy LockFlashing and Details GuideValley - 3:12 or Greater
OFFSET CLEAT(ELOC)
VALLEY LAP(3:12 or Greater Pitch)
WIDE VALLEY FLASHING(ELVFW)
VALLEY FLASHING(ELVF24)
VALLEY DETAIL(3:12 or Greater Pitch)
Valley Flashing Application• Install valley flashing by fastening through the pan as near to the outside edge (near the hem) as possible every 18" to 24" on each
side. Cover fastener heads with sealant/caulking. • Cut hems 6" back on each side of the next valley flashing. Apply three 1/4" beads of caulking between the valley pans. • Form valley flashing over the ridge as necessary. • Trim panels for angle of valley 2" from the valley center point.
Note: Be sure to remove any burrs from the cut edge of panels and use a damp cloth to wipe any filings from the panel. • If the panels crown (pan of panel raising up) backbend panel or use the 1/2" upending tool and either bend the panel end down 30
degrees or turn the 1/2" under, forming a hemmed edge. • Apply butyl mastic tape, or a 1/4" bead of sealant/caulking, up 1" from panel edge. • If using a wide valley, the panels will be set farther from the center of the valley pan, place butyl tape so it is 1" from end
of panel. • Apply a bead of sealant/caulking on top of the hems of the valley flashing. • Install panels being sure to fasten panels through the fastening flange into substrate, as close as possible to hemmed edge of
valley flashing. Do not penetrate the valley flashing. • Heavy snow conditions require a wider valley pan. Leave more space between the end of the valley panels and the valley
center line. • Consider using wide valley flashings for low pitch roofs.
Easy-Lock Installation Guide - 2020
21
Valley - Low PitchSlope Less than 3:12
TAYLORM E T A L P R O D U C T S
4"
22 GA. OFFSET CLEAT,SCREWED 8" O.C.
TRIPLE BEADBUTYL TAPE
TRIPLE ROW OFSKINNING
GUNNABLE BUTYL
NEOPRENE WASHERED SCREW1" FROM RIB AND 4" O.C.
UNDERLAYMENT
LAP UNDERLAYMENTOVER SCREW
1"
IF PAINTED,THIS SIDE
11"
SPECIFY PITCH
IF PAINTED,THIS SIDE
1"
15.875"
SPECIFY PITCH
.5" HEM, OPEN
THREE ROWS OFNON-SKINNING
GUNNABLE BUTYLAT LAP JOINT
12"
Easy LockFlashing and Details GuideValley - Low Pitch
VALLEY FLASHING DETAIL
VALLEY FLASHING 24"(ELVF24)
WIDE VALLEY FLASHING(ELVFW)
VALLEY LAP
4"
22 GA. OFFSET CLEAT,SCREWED 8" O.C.
TRIPLE BEADBUTYL TAPE
TRIPLE ROW OFSKINNING
GUNNABLE BUTYL
NEOPRENE WASHERED SCREW1" FROM RIB AND 4" O.C.
UNDERLAYMENT
LAP UNDERLAYMENTOVER SCREW
1"
IF PAINTED,THIS SIDE
11"
SPECIFY PITCH
IF PAINTED,THIS SIDE
1"
15.875"
SPECIFY PITCH
.5" HEM, OPEN
THREE ROWS OFNON-SKINNING
GUNNABLE BUTYLAT LAP JOINT
12"
Easy LockFlashing and Details GuideValley - Low Pitch
VALLEY FLASHING DETAIL
VALLEY FLASHING 24"(ELVF24)
WIDE VALLEY FLASHING(ELVFW)
VALLEY LAP
Easy-Lock Installation Guide - 2020
(Less Than 3:12 Pitch)
(Less Than 3:12 Pitch)
22
Box GableTAYLORM E T A L P R O D U C T S
IF PAINTED,THIS SIDE
145°
.5" KICK,.5" HEM,
OPEN
4"
2"
1"
.5" HEM
NEOPRENE WASHERED SCREWOR RIVET 12" O.C.
SCREW 8" O.C. WITHSEALANT OVER THE TOP
UNDERLAYMENT WRAPDOWN FACE 3" MINIMUM
DOUBLE BEADBUTYL TAPE
SUPPORT FLASHING
UDERLAYMENTWRAPPED DOWNFACE 2"
BEND PANEL1" AT 90°
BOX GABLE
SHEATHING
FASCIA
GABLE CLEAT
1"
3"
34"1
2"
18" 151°
114"
UNDERLAYMENT
SHEATHING
FASCIA
SUPPORTFLASHING
SCREW 8" O.C.WITH SEALANTOVER THE TOP
EASY-LOCK PANEL
BEND PANEL1" AT 90°
NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.
BOX GABLE
DOUBLE BEAD BUTYL TAPE
3.875"
145°
1"
.5" KICK
Easy LockFlashing and Details GuideBox Gable
SUPPORT FLASHING(ELSF)
BOX GABLE FLASHING(ELGB)
BOX GABLE DETAIL
GABLE CLEAT(ELBGC)
IF PAINTED,THIS SIDE
145°
.5" KICK,.5" HEM,
OPEN
4"
2"
1"
.5" HEM
NEOPRENE WASHERED SCREWOR RIVET 12" O.C.
SCREW 8" O.C. WITHSEALANT OVER THE TOP
UNDERLAYMENT WRAPDOWN FACE 3" MINIMUM
DOUBLE BEADBUTYL TAPE
SUPPORT FLASHING
UDERLAYMENTWRAPPED DOWNFACE 2"
BEND PANEL1" AT 90°
BOX GABLE
SHEATHING
FASCIA
GABLE CLEAT
1"
3"
34"1
2"
18" 151°
114"
UNDERLAYMENT
SHEATHING
FASCIA
SUPPORTFLASHING
SCREW 8" O.C.WITH SEALANTOVER THE TOP
EASY-LOCK PANEL
BEND PANEL1" AT 90°
NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.
BOX GABLE
DOUBLE BEAD BUTYL TAPE
3.875"
145°
1"
.5" KICK
Easy LockFlashing and Details GuideBox Gable
SUPPORT FLASHING(ELSF)
BOX GABLE FLASHING(ELGB)
BOX GABLE DETAIL
GABLE CLEAT(ELBGC)
Box Gable Flashing Application• Install to hold down beginning and/or
ending panel(s). • Trim last panel (if needed) to allow 1" leg
to be bent up to receive gable trim. • Place gable firmly over rib (or field formed
leg). • Overlap flashing 2" to 3" top over bottom
and place 1/8" bead of caulk under lap. • Fasten to fascia board every 24" with
woodfast screw. • Consider using compensating gable if
roof is out of square or to avoid cutting very narrow panel for the ending panel.
• Compensating gable flashing will allow installation to begin or end up to 2" from gable edge.
Easy-Lock Installation Guide - 2020
23
Prow TAYLORM E T A L P R O D U C T S
SCREW 8" O.C. WITHSEALANT OVER THE TOPCLOSE TO HEM
UNDERLAYMENT
PROW FLASHING
SHEATHING
FASCIA
SCREW 8" O.C.SEALANT UNDERCLEAT
OFFSET CLEAT EASY-LOCK PANEL
UNDERLAYMENT
SHEATHING
FASCIA
EASY-LOCK PANEL
PROW
SCREW 8" O.C.WITH SEALANTOVER THE TOPCLOSE TO HEM
OFFSET CLEAT
SCREW 8" O.C.
1.5"
1"
.5"
155° TYP.
.625"
12.5"
1"
.5" KICK,.5" HEM
IF PAINTED,THIS SIDE
.5" HEM, OPEN
1"
145°
4"
Easy LockFlashing and Details GuideProw Detail
OFFSET CLEAT(ELOC)
PROW FLASHING(ELPF)PROW DETAIL
Prow Application• Install the prow gable flashing on the roof prior to panels.• Fasten to fascia board every 24" with woodfast screw. • Fasten pan to sheathing with waferhead screw every 18"
to 24" as close to the hemmed edge as possible. Cover screw heads with sealant/caulking.
• Trim panels to angle of prow, 2" from the edge of the raised portion of the flashing. Note: Be sure to remove any burrs on the cut edge of the panel and use a damp cloth to wipe any filings from the panel.
• Apply butyl tape or 1/4" bead of sealant/caulking 3" from the raised edge of the prow flashing, (1" under end of panels). Apply a 1/4" bead of sealant/caulking to the top of the hem of the prow flashing.
• Fasten the panels as close to the hemmed edge of the prow flashing as possible.
• Due to the long cuts typical of the angle of the prow, using the 1/2" upending tool, bend the cut edge down 30 degrees or turn the edge under forming a hem.
SCREW 8" O.C. WITHSEALANT OVER THE TOPCLOSE TO HEM
UNDERLAYMENT
PROW FLASHING
SHEATHING
FASCIA
SCREW 8" O.C.SEALANT UNDERCLEAT
OFFSET CLEAT EASY-LOCK PANEL
UNDERLAYMENT
SHEATHING
FASCIA
EASY-LOCK PANEL
PROW
SCREW 8" O.C.WITH SEALANTOVER THE TOPCLOSE TO HEM
OFFSET CLEAT
SCREW 8" O.C.
1.5"
1"
.5"
155° TYP.
.625"
12.5"
1"
.5" KICK,.5" HEM
IF PAINTED,THIS SIDE
.5" HEM, OPEN
1"
145°
4"
Easy LockFlashing and Details GuideProw Detail
OFFSET CLEAT(ELOC)
PROW FLASHING(ELPF)PROW DETAIL
Easy-Lock Installation Guide - 2020
SCREW 8" O.C. WITHSEALANT OVER THE TOPCLOSE TO HEM
UNDERLAYMENT
PROW FLASHING
SHEATHING
FASCIA
SCREW 8" O.C.SEALANT UNDERCLEAT
OFFSET CLEAT EASY-LOCK PANEL
UNDERLAYMENT
SHEATHING
FASCIA
EASY-LOCK PANEL
PROW
SCREW 8" O.C.WITH SEALANTOVER THE TOPCLOSE TO HEM
OFFSET CLEAT
SCREW 8" O.C.
1.5"
1"
.5"
155° TYP.
.625"
12.5"
1"
.5" KICK,.5" HEM
IF PAINTED,THIS SIDE
.5" HEM, OPEN
1"
145°
4"
Easy LockFlashing and Details GuideProw Detail
OFFSET CLEAT(ELOC)
PROW FLASHING(ELPF)PROW DETAIL
IF PAINTED,THIS SIDE
4"
1"
1"
LAP UNDERLAYMENTOVER SCREW
UNDERLAYMENTTURN UP WALL 8"
NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.
SCREW 8" O.C. WITHSEALANT OVER THE TOP
SUPPORTFLASHING
BEND PANEL1" AT 90°
DOUBLE BEADBUTYL TAPE
WALL PANEL/SIDING
SHEATHING
SIDEWALL
EASY-LOCK PANEL
1"
3"
34"1
2"
18" 151°
114"
SHEATHING
WALL PANELLAP UNDERLAYMENTOVER SCREW
DOUBLE BEADBUTYL TAPE
SUPPORTFLASHING
EASY-LOCK PANEL
SIDEWALLUNDERLAYMENT
TURN UP WALL 8"
NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.
BEND PANEL1" AT 90°
IF PAINTED,THIS SIDE
4"
2"
1"
Easy LockFlashing and Details GuideSidewall
SUPPORT FLASHING(ELSF)
SIDEWALL & COMPENSATING SIDEWALL(ELSW)
SIDEWALL DETAIL
24
SidewallTAYLORM E T A L P R O D U C T S
Sidewall Application• Sidewall flashing is used
where wall runs parallel with slope.
• Install roofing panel first. • Flash over rib if starting
panels at wall or over upended edge of panel (pictured).
• Install flashing under siding (pictured). Attach to wall with waferhead screw for this option.OPTION: Siding is cut 1/4" deep and lip is caulked into the cut to seal. Attach to wall with woodfast screw every 24". Note: Specify with lip if using this method of installation.
• Overlap flashing end to end 2" to 3" and caulk at lap.
Easy-Lock Installation Guide - 2020
THREE ROWS OF NON-SKINNINGGUNNABLE BUTYL AT LAP JOINT
4" LAP1" BUTYL SPACING
EASY-LOCKPANEL
DOUBLE BEADBUTYL TAPE ON
LAP FLASHING
SKINNINGGUNNABLEBUTYL ON RIB
END RIDGE / PEAK
NEOPRENE WASHEREDSCREW OR RIVET 12" O.C.
INTO EACH END DAM /ZEE CLOSURE
SHEATHING
UNDERLAYMENT
NEOPRENE WASHEREDDRAG LOAD 1" FROM SIDE OF
RIB AND 4" O.C. MIN, DRAG LOADCALCULATIONS MAY REQUIRE MORE
CLEAT
ZEE CLOSURE / END DAM
4.125"
145°.5" KICK
SPECIFYPITCH
1"
IF PAINTED,THIS SIDE
SPECIFYPITCH
6"
4.25"
.5" KICK,.5" HEMAT 145°
.5" SLIGHTLYOPEN HEM
113°
IF PAINTED,THIS SIDE
SPECIFYPITCH
5.75"
4.25"
.5" KICKAT 145°
1"
Easy LockFlashing and Details GuideRidge End Cap / Peak Cap
PEAK FLASHING DETAIL FIELD NOTCHED PEAK FLASHING(ELREC)
PEAK CLEAT(ELRECC)
PEAK LAP
HEMMED PEAK FLASHING(ELRECH)
25
Peak Flashing(Ridge End Cap) TAYLOR
M E T A L P R O D U C T S
Peak Flashing Application (R. E. C.)• Notch 1" leg to fit over rib of panel. • Fasten through peak flashing into ribs of panel every 24 " with woodfast
screw or rivit. • Fasten through 4-3/4" leg of peak flashing into fascia board every 24"
with woodfast screw. • Overlap flashing end to end 2" to 3". Place 1/4" bead of caulk under lap. • Fasten peak flashing at lap with rivet or woodfast screw.
Easy-Lock Installation Guide - 2020
(Ridge End Cap)
4" LAP1" BUTYL GAP
THREE ROWS OF NON-SKINNINGGUNNABLE BUTYL AT LAP JOINT
2"
DOUBLE ROWOF NON-SKINNINGGUNNABLE BUTYL
STITCH SCREW EVERYOTHER RIB
NOTCH OVER RIB
ROW OF SKINNINGGUNNABLE BUTYL
SHEATHING
UNDERLAYMENT
EASY-LOCK PANEL
SCREW COVEREDIN SEALANT
PITCHTRANSITION
DOUBLE BEADBUTYL TAPE ONLAP FLASHING
DOUBLE BEADBUTYL TAPE
NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIB AND
4" O.C. MIN. DRAG LOAD CALCULATIONSMAY REQUIRE MORE.
SPECIFY PITCH
IF PAINTED,THIS SIDE
4"
6"
1"FIELD NOTCH
Easy LockFlashing and Details GuidePitch Transition
INSIDE PITCH CHANGE(ELPCIN)
PITCH CHANGE DETAIL
PITCH CHANGE LAP
26
Pitch ChangeTAYLORM E T A L P R O D U C T S
Pitch Change Inside Application• Install lower panels and all flashings associated
with the lower roof. Upend panels, apply sealant/caulking to corners of up-endeded pan.
• Notch 1" leg of flashing to fit over rib of panels.• Attach upper leg of flashing to sheathing with
a waferhead screw on the upper leg every 18" to 24" or as needed. Place sealant/caulking on screw head.
• Allow 3" overlap on flashing, apply three 1/4" beads of sealant/caulking under lap.
• Attach lower leg of flashing to every other rib, with a woodfast screw, rivet or stitch screw.
• Place a 1/4" bead of sealant/caulking on the upper leg of the flashing 1-1/2" from the break. Install the panels 1/2" from the break.Note: Custom flashings may be required when pitches are close, e.g. 3:12 to 1:12.
Easy-Lock Installation Guide - 2020
NOTCHEDENDWALL
EASY-LOCKPANEL
SHEATHING
WALL PANEL
LAP UNDERLAYMENTOVER SCREW
UNDERLAYMENT UP WALL 8"
NEOPRENE WASHERED SCREWOR RIVET AT 12" O.C.
WALL PANEL
EASY-LOCKPANEL
END WALL
ZEE / END DAM CLOSURE
DOUBLE BEADBUTYL TAPE ONLAP FLASHING
DOUBLE BEADBUTYL TAPE
NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIB AND4" O.C. MIN. DRAG LOAD CALCULATIONSMAY REQUIRE MORE.
4"
5"
IF PAINTED,THIS SIDE
.5" HEM, OPEN
SPECIFY PITCH
SHEATHING
Easy LockFlashing and Details GuideHemmed EndWall
HEMMED ENDWALL DETAILHEMMED ENDWALL FLASHING
(ELEWH)
27
Hemmed Endwall TAYLORM E T A L P R O D U C T S
Hemmed Endwall Application• Endwall flashing is used where the roof slopes
away from a wall (i.e., clerestory or shed roof.)• Up-end top of panel and apply sealants/caulking
to the corner of the up-ended pans before installing flashing.
• Notch 1" leg of endwall to fit over ribs of panels. • Upper leg (2-1/2") is placed under siding.
OPTION: Siding is cut 1/4" deep and the lip is caulked into the cut to seal. Note: Specify with lip if using this method of installation.
• Attach flashing to every other rib of panel with rivet, woodfast screw or stitch screw.
• Overlap flashing end to end 2" to 3". Place 1/4" bead of sealant/caulking under lap.
Easy-Lock Installation Guide - 2020
28
Vented EndwallTAYLORM E T A L P R O D U C T S
4"
6.5"
IF PAINTED,THIS SIDE
.5" HEM, OPEN
SPECIFY PITCH
1.125"
1.125"113° TYP.UNLESS NOTED
LAP UNDERLAYMENTOVER SCREW
UNDERLAYMENT UP WALL 8"
NEOPRENE WASHEREDSCREW AT 12" O.C.
VENT MESH
EASY-LOCKPANEL
SHEATHING
WALL PANEL
VENTED EW17
ZEE / END DAM
UPEND PANEL ENDCAULK CORNERS
DOUBLE BEADBUTYL TAPEON TAB
NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIB AND
4" O.C. MIN. DRAG LOAD CALCULATIONSMAY REQUIRE MORE.
4" LAP
3 BEADS OF SKINNINGGUNNABLE BUTYL
1"
Easy LockFlashing and Details GuideVented / EW17 End Wall
ENDWALL LAP
EW17 ENDWALL FLASHING(ELEW17)
VENTED ENDWALL DETAIL
Vented Endwall Application• Vented endwall flashing is used to provide
ventilation at the wall. Cut out or leave the sheathing back 2" from the wall and cover with vent mesh/flyscreen.
• Upend top of panel and caulk the corners before installing the flashing.
• Place the vented endwall flashing on top of the ribs of the panels. The upper leg (2-1/2") is placed under the siding. OPTION: Siding is cut 1/4" deep and the lip is caulked into the cut to seal. Note: Specify with lip if using this method of installation.
• Attach flashing to every other rib of panel with rivet, woodfast screw or stitch screw.
• Overlap flashing end to end 2" to 3". Place 1/4" bead of sealant/caulk under lap.
Easy-Lock Installation Guide - 2020
SCREW ENDDAM TO PANEL
SKINNING GUNNABLEBUTYL ON TOP OF RIBTO FILL GAPS
AFTER END DAM IS INSTALLED,FILL ALL VOIDS ON FRONT SIDEOF END DAM WITH SKINNINGGUNNABLE BUTYL.
DOUBLE BEADBUTYL TAPE
NEOPRENE WASHERSCREW 1" FROM RIB.4" O.C. MAY BE REQUIREDDEPENDING ON DRAG LOADREQUIREMENTS.
SCREW END DAMTO PANEL RIB
DOUBLE BEAD BUTYL TAPE.APPLY ON BOTTOM AND SIDES
OF END DAM.
DOUBLE BEADBUTYL TAPE
END DAM
SKINNING GUNNABLEBUTYL TO FILL GAPS
SCREW END DAMTO PANEL RIB
END DAM
NEOPRENE WASHERED DRAGLOAD 1" FROM SIDE OF RIBAND 4" O.C. MINIMUM, DRAGLOAD CALCULATIONS MAYREQUIRE MORE.
UNDERLAYMENTSHEATHING
EASY-LOCK PANEL
Easy LockEL Flashings: 10'End Dam Placement
End Dam TAYLORM E T A L P R O D U C T S
29
END DAM DETAIL
Easy-Lock Installation Guide - 2020
30
Eave to Gable TransitionTAYLORM E T A L P R O D U C T S
STEP 1
Eave to Gable Transition
1.5"
BEND UP 90°
CUT
REMOVE
BEND DOWN 90°CUT
1.5"
EASY-LOCKPANEL SHOWN
Easy LockEasy Lock Flashings: 10'
Easy-Lock Installation Guide - 2020
31
Eave to Gable Transition TAYLORM E T A L P R O D U C T S
TABBED EAVE
ICE AND WATERUNDERLAYMENT
HOOK EAVE
SUPPORTFLASHING
REMOVE TOP AND SIDE OFSUPPORT CLOSURE AT STARTOF HOOK EAVE.BASE OF SUPPORT FLASHINGSHOULD BE FLUSH WITH ENDOF HOOK EAVE.SET IN SEALANT.
FASCIA BOARD,EAVE
FASCIA BOARD,RAKE
1"
PANCAKESCREW
Easy LockEasy Lock Flashings: 10'
STEP 2
Easy-Lock Installation Guide - 2020
32
Eave to Gable TransitionTAYLORM E T A L P R O D U C T S
NOTCH GABLEAROUND EAVE.
SUPPORTFLASHING
GABLE
FOLD PANELAROUNDHOOK EAVE.
CAP GABLEAND SEAL.
PLACE PANEL ON TOPOF SUPPORT FLASHING,WITH UPEND OF PANELINSIDE CLOSURE.
PLACE FOLD AGAINSTHOOK EAVE FLASHING.
Easy LockEasy Lock Flashings: 10'
STEP 3
STEP 4
Easy-Lock Installation Guide - 2020
33
Skylight / Chimney TAYLORM E T A L P R O D U C T S
Easy-Lock Installation Guide - 2020
Skylight / Chimney Trim
For 2" x 4" Curbing
5-1/2" Pan Flashing (ELP5)
Apply parts as described on the following pages. Please note that the 12-inch leg of the pan flashing used on a chimney application will need to be bent to the pitch of the roof.
3-1/2" Pan Flashing (ELP3)
For 2" x 6" Curbing
4-1/2" Side and Bottom Flashing (ELSB5)
2-1/2" Side and Bottom Flashing (ELSB3)
IF PAINTED,THIS SIDE
4"
1"
1"
IF PAINTED,THIS SIDE
4"
2"
1"
4"
4.75"
IF PAINTED,THIS SIDE
1"
SPECIFY PITCH
4"
5"
IF PAINTED,THIS SIDE
.5" HEM, OPEN
SPECIFY PITCH
1"
4"
7"
SPECIFY PITCH
IF PAINTED,THIS SIDE
FIELD NOTCH
SPECIFY PITCH
IF PAINTED,THIS SIDE
4"
6"
1"FIELD NOTCH
4"
6.5"
IF PAINTED,THIS SIDE
.5" HEM, OPEN
SPECIFY PITCH
1.125"
1.125"113° TYP.UNLESS NOTED
12.5"
1"
.5" KICK,.5 HEM
IF PAINTED,THIS SIDE
.5" HEM, OPEN
1"
145°
4"
1"
1" Streamline7
8" Snap Lock
1"
IF PAINTED,THIS SIDE
WEIGHT: 5.0 LBS.S.O. 6"SCALE 1:3
( SLSW )SIDEWALL
WEIGHT: 5.8 LBS.S.O. 7"SCALE 1:3
( SLSWC )COMPENSATING SIDEWALL
WEIGHT: 7.9 LBS.S.O. 9.5"SCALE 1:3
( SLEWH )ENDWALL STANDARD HEMMED
WEIGHT: 8.1 LBS.S.O. 9.75"SCALE 1:3
( SLEWN )ENDWALL FIELD NOTCHED
WEIGHT: 9.9 LBS.S.O. 12"SCALE 1:5WEIGHT: 9.1 LBS.S.O. 11"SCALE 1:5
WEIGHT: 11.5 LBS.S.O. 13.25"SCALE 1:4
( SLEW17 )EW-17 VENTED ENDWALL
WEIGHT: 13.8 LBS.S.O. 20"SCALE 1:6
( SLPF )PROW
Streamline / Snap LocStreamline / Snap Loc Flashings: 12' 6"Streamline Hems 12" / Snap Loc Hems 12"
WEIGHT: 2.64 LBS.S.O. 3" / 2.875"SCALE 1:2
( SLZC )ZEE CLOSUREOUTSIDE PITCH CHANGE
( SLPCON )FIELD NOTCHED
OUTSIDE PITCH CHANGE
( SLPCIN )FIELD NOTCHED
4-1/2"
IF PAINTED,THIS SIDE
4"
1"
1"
IF PAINTED,THIS SIDE
4"
2"
1"
4"
4.75"
IF PAINTED,THIS SIDE
1"
SPECIFY PITCH
4"
5"
IF PAINTED,THIS SIDE
.5" HEM, OPEN
SPECIFY PITCH
1"
4"
7"
SPECIFY PITCH
IF PAINTED,THIS SIDE
FIELD NOTCH
SPECIFY PITCH
IF PAINTED,THIS SIDE
4"
6"
1"FIELD NOTCH
4"
6.5"
IF PAINTED,THIS SIDE
.5" HEM, OPEN
SPECIFY PITCH
1.125"
1.125"113° TYP.UNLESS NOTED
12.5"
1"
.5" KICK,.5 HEM
IF PAINTED,THIS SIDE
.5" HEM, OPEN
1"
145°
4"
1"
1" Streamline7
8" Snap Lock
1"
IF PAINTED,THIS SIDE
WEIGHT: 5.0 LBS.S.O. 6"SCALE 1:3
( SLSW )SIDEWALL
WEIGHT: 5.8 LBS.S.O. 7"SCALE 1:3
( SLSWC )COMPENSATING SIDEWALL
WEIGHT: 7.9 LBS.S.O. 9.5"SCALE 1:3
( SLEWH )ENDWALL STANDARD HEMMED
WEIGHT: 8.1 LBS.S.O. 9.75"SCALE 1:3
( SLEWN )ENDWALL FIELD NOTCHED
WEIGHT: 9.9 LBS.S.O. 12"SCALE 1:5WEIGHT: 9.1 LBS.S.O. 11"SCALE 1:5
WEIGHT: 11.5 LBS.S.O. 13.25"SCALE 1:4
( SLEW17 )EW-17 VENTED ENDWALL
WEIGHT: 13.8 LBS.S.O. 20"SCALE 1:6
( SLPF )PROW
Streamline / Snap LocStreamline / Snap Loc Flashings: 12' 6"Streamline Hems 12" / Snap Loc Hems 12"
WEIGHT: 2.64 LBS.S.O. 3" / 2.875"SCALE 1:2
( SLZC )ZEE CLOSUREOUTSIDE PITCH CHANGE
( SLPCON )FIELD NOTCHED
OUTSIDE PITCH CHANGE
( SLPCIN )FIELD NOTCHED
IF PAINTED,THIS SIDE
4"
1"
1"
IF PAINTED,THIS SIDE
4"
2"
1"
4"
4.75"
IF PAINTED,THIS SIDE
1"
SPECIFY PITCH
4"
5"
IF PAINTED,THIS SIDE
.5" HEM, OPEN
SPECIFY PITCH
1"
4"
7"
SPECIFY PITCH
IF PAINTED,THIS SIDE
FIELD NOTCH
SPECIFY PITCH
IF PAINTED,THIS SIDE
4"
6"
1"FIELD NOTCH
4"
6.5"
IF PAINTED,THIS SIDE
.5" HEM, OPEN
SPECIFY PITCH
1.125"
1.125"113° TYP.UNLESS NOTED
12.5"
1"
.5" KICK,.5 HEM
IF PAINTED,THIS SIDE
.5" HEM, OPEN
1"
145°
4"
1"
1" Streamline7
8" Snap Lock
1"
IF PAINTED,THIS SIDE
WEIGHT: 5.0 LBS.S.O. 6"SCALE 1:3
( SLSW )SIDEWALL
WEIGHT: 5.8 LBS.S.O. 7"SCALE 1:3
( SLSWC )COMPENSATING SIDEWALL
WEIGHT: 7.9 LBS.S.O. 9.5"SCALE 1:3
( SLEWH )ENDWALL STANDARD HEMMED
WEIGHT: 8.1 LBS.S.O. 9.75"SCALE 1:3
( SLEWN )ENDWALL FIELD NOTCHED
WEIGHT: 9.9 LBS.S.O. 12"SCALE 1:5WEIGHT: 9.1 LBS.S.O. 11"SCALE 1:5
WEIGHT: 11.5 LBS.S.O. 13.25"SCALE 1:4
( SLEW17 )EW-17 VENTED ENDWALL
WEIGHT: 13.8 LBS.S.O. 20"SCALE 1:6
( SLPF )PROW
Streamline / Snap LocStreamline / Snap Loc Flashings: 12' 6"Streamline Hems 12" / Snap Loc Hems 12"
WEIGHT: 2.64 LBS.S.O. 3" / 2.875"SCALE 1:2
( SLZC )ZEE CLOSUREOUTSIDE PITCH CHANGE
( SLPCON )FIELD NOTCHED
OUTSIDE PITCH CHANGE
( SLPCIN )FIELD NOTCHED
2-1/2"
IF PAINTED,THIS SIDE
4"
1"
1"
IF PAINTED,THIS SIDE
4"
2"
1"
4"
4.75"
IF PAINTED,THIS SIDE
1"
SPECIFY PITCH
4"
5"
IF PAINTED,THIS SIDE
.5" HEM, OPEN
SPECIFY PITCH
1"
4"
7"
SPECIFY PITCH
IF PAINTED,THIS SIDE
FIELD NOTCH
SPECIFY PITCH
IF PAINTED,THIS SIDE
4"
6"
1"FIELD NOTCH
4"
6.5"
IF PAINTED,THIS SIDE
.5" HEM, OPEN
SPECIFY PITCH
1.125"
1.125"113° TYP.UNLESS NOTED
12.5"
1"
.5" KICK,.5 HEM
IF PAINTED,THIS SIDE
.5" HEM, OPEN
1"
145°
4"
1"
1" Streamline7
8" Snap Lock
1"
IF PAINTED,THIS SIDE
WEIGHT: 5.0 LBS.S.O. 6"SCALE 1:3
( SLSW )SIDEWALL
WEIGHT: 5.8 LBS.S.O. 7"SCALE 1:3
( SLSWC )COMPENSATING SIDEWALL
WEIGHT: 7.9 LBS.S.O. 9.5"SCALE 1:3
( SLEWH )ENDWALL STANDARD HEMMED
WEIGHT: 8.1 LBS.S.O. 9.75"SCALE 1:3
( SLEWN )ENDWALL FIELD NOTCHED
WEIGHT: 9.9 LBS.S.O. 12"SCALE 1:5WEIGHT: 9.1 LBS.S.O. 11"SCALE 1:5
WEIGHT: 11.5 LBS.S.O. 13.25"SCALE 1:4
( SLEW17 )EW-17 VENTED ENDWALL
WEIGHT: 13.8 LBS.S.O. 20"SCALE 1:6
( SLPF )PROW
Streamline / Snap LocStreamline / Snap Loc Flashings: 12' 6"Streamline Hems 12" / Snap Loc Hems 12"
WEIGHT: 2.64 LBS.S.O. 3" / 2.875"SCALE 1:2
( SLZC )ZEE CLOSUREOUTSIDE PITCH CHANGE
( SLPCON )FIELD NOTCHED
OUTSIDE PITCH CHANGE
( SLPCIN )FIELD NOTCHED
6"
IF PAINTED,THIS SIDE
SPECIFYPITCH
96°
1" 96°3
4"
IF PAINTED,THIS SIDE
SPECIFYPITCH
1"
5.75"
4.25"
.5" KICK,.5" OPEN HEM
AT 145°
IF PAINTED,THIS SIDE
SPECIFYPITCH
7.125"
1.125"
.5" OPEN HEM
117° TYP. UNLESS NOTED1.25"
IF PAINTED,THIS SIDESPECIFY
PITCH1.125"
6"
5.25"
.5" KICK,.5" HEMAT 145°
.75"
.5" SLIGHTLYOPEN HEM
113°
IF PAINTED,THIS SIDESPECIFY
PITCH
6"
4.25"
.5" KICK,.5" HEMAT 145°
.5" SLIGHTLYOPEN HEM
113°
IF PAINTED,THIS SIDE
145°
.5" KICK,.5" HEM,
OPEN
4"
2"
1"
.5" HEMIF PAINTED,
IF PAINTED,THIS SIDE
145°
.5" KICK
4"
2"
1"
.75"
7"
IF PAINTED,THIS SIDE
SPECIFY PITCH
58"96°
1212"
512"
IF PAINTED, THIS SIDE
312"
1212"
IF PAINTED, THIS SIDE
Streamline / Snap LocStreamline / Snap Loc Flashings: 12' 6"Streamline Hems 12" / Snap Loc Hems 12"
SCALE 1:4 S.O. 16.75" WEIGHT: 13.1 LBS.
FIELD NOTCHED RIDGE (UNVENTED)( SLRS )
R17 RIDGE( SLR17 )
SCALE 1:5 S.O. 20" WEIGHT: 15.6 LBS.
FIELD NOTCHED RIDGE END CAP (PEAK)( SLREC )
SCALE 1:4 S.O. 12" WEIGHT: 8.4 LBS.
VENTED RIDGE END CAP (PEAK)( SLRECV )
SCALE 1:5
S.O. 14.625"
WEIGHT: 11.80 LBS.
HEMMED RIDGE END CAP (PEAK)( SLRECH )
SCALE 1:5
S.O. 11.75"
WEIGHT: 10.45 LBS.
WEIGHT: 7.2 LBS.S.O. 8.5"SCALE 1:4
( SLGB )BOX GABLE
WEIGHT: 7.2 LBS.S.O. 7.5"SCALE 1:4
( SLGBNH )BOX GABLE NO HEM
SCALE 1:4 S.O. 16.75" WEIGHT: 13.1 LBS.
FULL VENTED RIDGE( SLRFV )
3.5" PAN FLASHING( SLP3 )
SCALE 1:5 S.O. 16" WEIGHT: 7.6 LBS.
5.5" PAN FLASHING( SLP5 )
SCALE 1:5
S.O. 18"
WEIGHT: 8.2 LBS.
6"
IF PAINTED,THIS SIDE
SPECIFYPITCH
96°
1" 96°3
4"
IF PAINTED,THIS SIDE
SPECIFYPITCH
1"
5.75"
4.25"
.5" KICK,.5" OPEN HEM
AT 145°
IF PAINTED,THIS SIDE
SPECIFYPITCH
7.125"
1.125"
.5" OPEN HEM
117° TYP. UNLESS NOTED1.25"
IF PAINTED,THIS SIDESPECIFY
PITCH1.125"
6"
5.25"
.5" KICK,.5" HEMAT 145°
.75"
.5" SLIGHTLYOPEN HEM
113°
IF PAINTED,THIS SIDESPECIFY
PITCH
6"
4.25"
.5" KICK,.5" HEMAT 145°
.5" SLIGHTLYOPEN HEM
113°
IF PAINTED,THIS SIDE
145°
.5" KICK,.5" HEM,
OPEN
4"
2"
1"
.5" HEMIF PAINTED,
IF PAINTED,THIS SIDE
145°
.5" KICK
4"
2"
1"
.75"
7"
IF PAINTED,THIS SIDE
SPECIFY PITCH
58"96°
1212"
512"
IF PAINTED, THIS SIDE
312"
1212"
IF PAINTED, THIS SIDE
Streamline / Snap LocStreamline / Snap Loc Flashings: 12' 6"Streamline Hems 12" / Snap Loc Hems 12"
SCALE 1:4 S.O. 16.75" WEIGHT: 13.1 LBS.
FIELD NOTCHED RIDGE (UNVENTED)( SLRS )
R17 RIDGE( SLR17 )
SCALE 1:5 S.O. 20" WEIGHT: 15.6 LBS.
FIELD NOTCHED RIDGE END CAP (PEAK)( SLREC )
SCALE 1:4 S.O. 12" WEIGHT: 8.4 LBS.
VENTED RIDGE END CAP (PEAK)( SLRECV )
SCALE 1:5
S.O. 14.625"
WEIGHT: 11.80 LBS.
HEMMED RIDGE END CAP (PEAK)( SLRECH )
SCALE 1:5
S.O. 11.75"
WEIGHT: 10.45 LBS.
WEIGHT: 7.2 LBS.S.O. 8.5"SCALE 1:4
( SLGB )BOX GABLE
WEIGHT: 7.2 LBS.S.O. 7.5"SCALE 1:4
( SLGBNH )BOX GABLE NO HEM
SCALE 1:4 S.O. 16.75" WEIGHT: 13.1 LBS.
FULL VENTED RIDGE( SLRFV )
3.5" PAN FLASHING( SLP3 )
SCALE 1:5 S.O. 16" WEIGHT: 7.6 LBS.
5.5" PAN FLASHING( SLP5 )
SCALE 1:5
S.O. 18"
WEIGHT: 8.2 LBS.
34
Skylight / ChimneyTAYLORM E T A L P R O D U C T S
The following instructions are applicable to most typical skylight or chimney applications. However, your individual application may be unique and require custom flashing and/or special installation. Be sure to check with the skylight manufacturer to determine recommended flashing and whether deviation will result in nullifying your warranty. The use of a cricket is advised in some situations, especially where the drainage is into a curb that exceeds 2'6", or if the roof area will have a lot of debris falling on it. Crickets are specially made to fit the curb/chimney and are used in place of the head flashing. Installation information for the cricket and the head flashing is the same.
3" 3"
6"
3"
3"
6"
3"
6"
3"
6"
3"3"
Skylight / Chimney Application
Dotted lines show where to cut.
Parts shown after they have been cut and bent.#3 is the Pan flashing. Order the proper size for the curb height of your skylight, 5-1/2" (ELP5) or 3-1/2" (ELP3).
Step 1: Working from left to right, cut to fit, bend and install panel #1.
Step 2: Cut to fit, bend and install panel #2. (Install additional panels as normal, between panels #1 and #2, as needed to cover width of skylight/chimney opening).
Step 3: The next piece to install is the pan flashing #3. First place a bead of skinning butyl sealant on top of panel #1 and #2 to stop any water from siphoning at the joint. Next, cut and bend the pan flashing to fit. The artificial ribs should be ½” high. Set and fasten.
#1
#1
#2
#2
#3
#3
Easy-Lock Installation Guide - 2020
#5#4
#1 #2
#6
#8
#3
#7
3"
3"
#6
#6
#7 & #8
#7 & #8
35
Skylight / Chimney TAYLORM E T A L P R O D U C T S
Note: Skinning butyl sealant should be used at all joints and where the metal is to be overlapped. Note: The care and attention to detail that is used when installing the flashings determines the overall finished appearance. Note: The preceding information is designed as a general guideline to be used and is not the only acceptable method to flash a skylight.
Diagram of part placement around the skylight.
Parts shown after they have been cut.
Dotted lines show where to cut. Parts #6, #7 and #8 are all the Sidewall flashing (ELSB5 or ELSB3). The only difference is the way they are cut and bent on the job. Again, order the proper size curb height of your skylight.
Step 4: Working from left to right, cut and install panel #4, snapping it into place and continue fastening as usual.
Step 5: Cut and install panel #5. (Install additional panels as normal, between panels #1 and #2, as needed to cover width of skylight/chimney opening).
Step 6: Install the bottom flashing #6 as you would the standard endwall flashing. Next, apply sidewall flashing #7 and #8 finishing off around the curb of the skylight.
Dotted lines show where to cut
Parts shown after they have been cut and bent.
#4
#5
#5
#4
Easy-Lock Installation Guide - 2020
#5#4
#1 #2
#6
#8
#3
#7
3"
3"
#5#4
#1 #2
#6
#8
#3
#7
3"
3"
36
Pipe Penetration - on PlateTAYLORM E T A L P R O D U C T S
Easy-Lock Installation Guide - 2020
ROOFPANEL
UNDERLAYMENT
22 GA PLATEFASTENED TO DECK
BOTTOM OF RIVET.DO NOT PENETRATEPLATE.
FOR PIPES LOCATED 20' OR GREATER FROM PIN POINT
SINGLE 22 GAUGE PLATE TWO OVERLAPPING 22 GAUGE PLATES
SEAL
SOLID SHANKWATERPROOF RIVET
SS HOSE CLAMP
Easy LockEasy Lock Flashings: 10'Pipe Penetration
Allows panel and pipe flashing to move with temperature change.
Pipe Penetration - on Rib TAYLORM E T A L P R O D U C T S
.75" X .125" BUTYL TAPE
SCREW ZEE CLOSURE4" O.C. MINIMUM
SEAL EXTERIOROF ZEE CLOSURES
.75" X .125" BUTYL TAPE
CUT HOLE IN PANELAT LEAST 1" LARGERTHAN PIPE
Easy LockFlashing and Details GuidePipe Penetration - On Pan
37
Easy-Lock Installation Guide - 2020
Pipe Penetration - on RibTAYLORM E T A L P R O D U C T S
SET HOSE CLAMPAT TOP OF PIPE
BOOT OR SEAL WITHUV RESISTANT SEALANT
NEOPRENE WASHEREDSCREW 1.25" O.C. MINIMUM
PIPE BOOT
BEAD OF SEALANT
.75" X .125" BUTYL TAPE
CUT HOLE 1"LARGER THAN PIPE
NEOPRENE WASHEREDSCREW 4" O.C. MINIMUM
.5" DOWNTURNON CAP.
HEM BACK OVERZEE CLOSURE
OR FASTEN 4" O.C.
Easy LockFlashing and Details GuidePipe Penetration - On Pan
38
Easy-Lock Installation Guide - 2020
Pipe Penetration - on Plate TAYLORM E T A L P R O D U C T S
SET HOSE CLAMP AT TOPOR USE UV RESISTANT SEALANT
NEOPRENE WASHEREDSCREW 1.25" O.C.
PIPE BOOT
2" MIN
BEAD OF SEALANT
.75" X .125" BUTYL TAPECUT HOLE 1"
LARGER THAN PIPE
Easy LockFlashing and Details GuidePipe Penetration - On Pan
39
Easy-Lock Installation Guide - 2020
Easy-Lock™Flashing and Details Selection
Flashing: 10' Standard
40
TAYLORM E T A L P R O D U C T S
4"
1.75"
145°.5" KICK
IF PAINTED,THIS SIDE
90° ORROOF PITCH
4"
1.5"SPECIFY PITCH
.5" KICK,.5" HEM,
OPEN AT 145°
IF PAINTED,THIS SIDE
108°
IF PAINTED,THIS SIDE
.5" KICK
2.8125"
1.125"
2.5"
1.125"
155°
108°
145°
IF PAINTED,THIS SIDE
108°
145°.5" KICK
2.8125"
1.125"
.375"
.875"
155°
1.125"
.5" KICK,.5" HEM,
OPEN
IF PAINTED,THIS SIDE
4.375"
1.5"
SPECIFYPITCH
145°
IF PAINTED,THIS SIDE
4"
2.25"
1.25"
120°
.5" HEM,OPEN
.5" KICK,.5" HEM,
OPEN 145°
.75"
IF PAINTED,THIS SIDE
2.8125"
1.125"
2.5"
1.125"
155°
108°108°
145°
.5" HEM,OPEN
.5" KICK,.5" HEM,
OPEN
1"
3"
SPECIFY PITCH
IF PAINTED,THIS SIDE
.5" HEM, OPEN
1.25"
1.375"
2.375"
.5" HEM, CLOSED
IF PAINTED,THIS SIDE
WEIGHT: 5.0 LBS.S.O. 6.25"SCALE 1:2
( ELELP )EAVE LOW
WEIGHT: 5.8 LBS.S.O. 6.5"SCALE 1:2
( ELE1.5 )1 1/2" EAVE
WEIGHT: 6.9 LBS.S.O. 8"SCALE 1:2
( ELEH )HOOK EAVE
WEIGHT: 5.4 LBS.S.O. 5.6875"SCALE 1:3
( ELGN )NARROW GABLE
WEIGHT: 7.0 LBS.S.O. 8.0625"SCALE 1:3
( ELGC )COMPENSATING GABLE
WEIGHT: 8.5 LBS.S.O. 9.75"SCALE 1:3
( ELGG17 )GABLE G-17
WEIGHT: 7.9 LBS.S.O. 9.0625"SCALE 1:3
( ELGCH )COMPENSATING GABLE HEMMED
WEIGHT: 3.4 LBS.S.O. 4.5"SCALE 1:2
( ELE13 ) EL 1"X3" EAVE FLASHING
Easy LockEasy Lock Flashings: 10'Easy Lock Hems: 12"
WEIGHT: 4.5 LBS.S.O. 5.5" / 5.375"SCALE 1:2
( ELCF )C-FLASHING
Easy-Lock Installation Guide - 2020
Easy-Lock™Flashing and Details SelectionFlashing: 10' Standard
41
TAYLORM E T A L P R O D U C T S
6"
SPECIFYPITCH
96°
1" 96°3
4"
IF PAINTED,THIS SIDE
IF PAINTED,THIS SIDE
SPECIFYPITCH
7.125"
1.125"
.5" OPEN HEM
117° TYP. UNLESS NOTED1.25"
IF PAINTED,THIS SIDE
SPECIFYPITCH
1"
5.75"
4.25"
.5" KICK,.5" OPEN HEM
AT 145°
.75"
7"
IF PAINTED,THIS SIDE
SPECIFY PITCH
58"96°
IF PAINTED,THIS SIDESPECIFY
PITCH1.125"
6"
5.25"
.5" KICK,.5" HEMAT 145°
.75"
.5"SLIGHTLY
OPEN HEM
113°
IF PAINTED,THIS SIDE
SPECIFYPITCH
6"
4.25"
.5" KICK,.5" HEMAT 145°
.5" SLIGHTLYOPEN HEM
113°
IF PAINTED,
IF PAINTED,THIS SIDE
145°
.5" KICK,.5" HEM,
OPEN
4"
2"
1"
.5" HEM
IF PAINTED,THIS SIDE
145°.5" KICK,
4"
2"
1"
1212"
512"
IF PAINTED, THIS SIDE
312"
1212"
IF PAINTED, THIS SIDE
Easy LockEasy Lock Flashings: 10'Easy Lock: 12"
SCALE 1:4 S.O. 16.75" WEIGHT: 13.1 LBS.
FIELD NOTCHED RIDGE (UNVENTED)( ELRS )
FULL VENTED RIDGE( ELRFV )
SCALE 1:5 S.O. 16.75" WEIGHT: 13.1 LBS.
R-17 RIDGE( ELR17 )
SCALE 1:5 S.O. 20" WEIGHT: 15.6 LBS.
FIELD NOTCHED PEAK FLASHING( ELREC )
SCALE 1:4 S.O. 12" WEIGHT: 8.4 LBS.
VENTED PEAK FLASHING( ELRECV )
SCALE 1:5
S.O. 14.625"
WEIGHT: 11.80 LBS.
HEMMED PEAK FLASHING( ELRECH )
SCALE 1:5
S.O. 11.75"
WEIGHT: 10.45 LBS.
WEIGHT: 7.2 LBS.S.O. 8.5"SCALE 1:4
( ELGB )BOX GABLE
WEIGHT: 7.2 LBS.S.O. 7.5"SCALE 1:4
( ELGBNH )BOX GABLE NO HEM
5.5" PAN FLASHING( ELP5 )
SCALE 1:5
S.O. 18"
WEIGHT: 8.2 LBS.
3.5" PAN FLASHING( ELP3 )
SCALE 1:5 S.O. 16" WEIGHT: 7.6 LBS.
Easy-Lock Installation Guide - 2020
Easy-Lock™Flashing and Details Selection
Flashing: 10' Standard
42
TAYLORM E T A L P R O D U C T S
IF PAINTED,THIS SIDE
5"
SPECIFY PITCH96°3
4"1"
96°5
8"
5.625"
.5" HEM, OPEN
IF PAINTED,THIS SIDE
SPECIFY PITCH
IF PAINTED,THIS SIDE
1"
10.5"
SPECIFY PITCH
.5" HEM, OPEN
1"
IF PAINTED,THIS SIDE
11"
SPECIFY PITCH
IF PAINTED,THIS SIDE 1"
15.875"
SPECIFY PITCH
.5" HEM, OPEN
6"
1"
12"
12"
WEIGHT: 12.1 LBS.S.O. 14.75"SCALE 1:4
( ELHS )FIELD NOTCHED HIP
WEIGHT: 10.1 LBS.S.O. 12.25"SCALE 1:4
( ELHR )HIP/RIDGE (SPECIFY)
VALLEY FLASHING 24"( ELVF24 )
SCALE 1:7 S.O. 24" WEIGHT: 19.6 LBS.
VALLEY FLASHING 24" HEMMED( ELVF24H )
SCALE 1:7 S.O. 24" WEIGHT: 19.6 LBS.
VALLEY WIDE FLASHING( ELVFW )
SCALE 1:5
S.O. 34.75"
WEIGHT: 28.2 LBS.
Easy LockEasy Lock Flashings: 10'Easy Lock Hems: 12"
GUTTER HANGER( AGH6 )
SCALE 1:2
S.O. 8"
WEIGHT: 6.5 LBS.
Easy-Lock Installation Guide - 2020
TAYLORM E T A L P R O D U C T S
Easy-Lock™Flashing and Details SelectionFlashing: 10' Standard
43
IF PAINTED,THIS SIDE
4"
1"
1"
IF PAINTED,THIS SIDE
4"
2"
1"
4"
4.75"
IF PAINTED,THIS SIDE
1"
SPECIFY PITCH
4"
5"
IF PAINTED,THIS SIDE
.5" HEM, OPEN
SPECIFY PITCH
1"
4"
7"
SPECIFY PITCH
IF PAINTED,THIS SIDE
FIELD NOTCH
SPECIFY PITCH
IF PAINTED,THIS SIDE
4"
6"
1"FIELD NOTCH
4"
6.5"
IF PAINTED,THIS SIDE
.5" HEM, OPEN
SPECIFY PITCH
1.125"
1.125"113° TYP.UNLESS NOTED
12.5"
1"
.5" KICK,.5" HEM
IF PAINTED,THIS SIDE
.5" HEM, OPEN
1"
145°
4"
1"
1"
1"
IF PAINTED,THIS SIDE
WEIGHT: 5.0 LBS.S.O. 6"SCALE 1:3
( ELSW )SIDEWALL
WEIGHT: 5.8 LBS.S.O. 7"SCALE 1:3
( ELSWC )COMPENSATING SIDEWALL
WEIGHT: 7.9 LBS.S.O. 9.5"SCALE 1:3
( ELEWH )HEMMED ENDWALL
WEIGHT: 8.1 LBS.S.O. 9.75"SCALE 1:3
( ELEWN )FIELD NOTCHED ENDWALL
WEIGHT: 9.9 LBS.S.O. 12"SCALE 1:5WEIGHT: 9.1 LBS.S.O. 11"SCALE 1:5
WEIGHT: 11.5 LBS.S.O. 13.25"SCALE 1:4
( ELEW17 )EW-17 VENTED ENDWALL
WEIGHT: 13.8 LBS.S.O. 19.5"SCALE 1:6
( ELPF )PROW
Easy LockEasy Lock Flashings: 10'Easy Lock Hems: 12"
WEIGHT: 2.64 LBS.S.O. 3"SCALE 1:2
( ELZC )ZEE CLOSUREFIELD NOTCHED INSIDE
( ELPCIN )PITCH CHANGE
FIELD NOTCHED OUTSIDE
( ELPCIN )PITCH CHANGE
Easy-Lock Installation Guide - 2020
TAYLORM E T A L P R O D U C T S
Easy-Lock™Flashing and Details Selection
Flashing: 10' Standard
44
SPECIFY PITCH
IF PAINTED,THIS SIDE
7"
4.5"
.5" HEM,CLOSED
4"
6"
SPECIFY PITCH
IF PAINTED,THIS SIDE
.5" HEM,CLOSED
45°
1.6875"
.3125"
1"
3"
34"1
2"
18" 151°
114"
1.5"
1"
.5"
155° TYP.
SPECIFY PITCH
IF PAINTED,THIS SIDE
SPECIFY DIMENSIONS163
4" STRETCH OUT
3.875"
145°
1"
.5" KICK
4"
4.125"
145°
.5" KICK
SPECIFYPITCH
1"
WEIGHT: 9.9 LBS.S.O. 12"SCALE 1:4
( ELPCOH )OUTSIDE PITCH CHANGE HEMMED
WEIGHT: 9.1 LBS.S.O. 10.5"SCALE 1:4
( ELPCIH )INSIDE PITCH CHANGE HEMMED
WEIGHT: 1.8 LBS.S.O. 2"SCALE 1:2
( ELSR )REVERSING STRIP (10')
WEIGHT: 2.6 LBS.S.O. 3"SCALE 1:2
( ELOC )OFFSET CLEAT (10')
WEIGHT: 5.0 LBS.S.O. 6.5"SCALE 1:2
( ELSF )SUPPORT FLASHING (10')
WEIGHT: 4.5 LBS.S.O. 5.375"SCALE 1:2
( ELBGC )GABLE CLEAT (10')
Easy LockEasy Lock Flashings: 10'Easy Lock Hems: 12"
WEIGHT: 13.8 LBS.S.O. 16.75"SCALE 1:6
( ELPAN )PAN
NON-VISIBLE / SUB-FLASHING ARE NOT PROVIDE IN SPECIFIC COLORS UNLESS SPECIFIED
WEIGHT: 2.5 LBS.S.O. 4"SCALE 1:2
( ELPS )4" PERF STRIP (10')
WEIGHT: 4.5 LBS.S.O. 5.375"SCALE 1:2
( ELRECC)PEAK CLEAT
Easy-Lock Installation Guide - 2020
TAYLORM E T A L P R O D U C T S
4"
10.9375"
2"
2"
2"
12.9375"
2"
1"
*END DAM IS EXAMPLEONLY. SEE SPECIFIC ENDDAM DETAIL SHEET FORDIMENSIONS (SEPARATEFORM).
12" HEM,
CLOSED
2"
1"
8.375"
WEIGHT: 2.5 LBS.S.O. 4"SCALE 1:2
( ELPS )4" PERF STRIP
IF PAINTED,APPLIED ON UNDERSIDE
WEIGHT: 0.34 LBS.
S.O. 3.5" x 16.75"
SCALE 1:8
( ELRF )RIDGE FINIAL
WEIGHT: VARIES
S.O. VARIES
SCALE 1:8
EASY-LOCK END DAM
Easy LockEasy Lock Flashings: 10'
33
Easy-Lock™Flashing and Details SelectionFlashing: 10' Standard
45
Easy-Lock Installation Guide - 2020
(PG. 29)
Panels with * need Pattern Choice:□Ribs □Striations □Flat Notched? Y / N Clip Relief? Y / N Sealant? Y / N
Job Name: Ship To: □ Will Call Day:
Order Form □ New Order □ Add-on Order □ Quote
Inside Sale:
PO #: Date:
□ Delivery Delivery Date:
PBRMarion “R” Panel2-1/2" CorrugatedClassic 7/8" CorrugatedGR-7HR-34T-3Tuff-Rib
□□□□□□□□
12" Easy-Lock*16" Easy-Lock*16" StreamLine*12" CL-175*
□□ □□ □ □□□□
Color: Pitch: Gauge: Dmatch: Pallet: 10' 20' 30'
Panel & Flashing Items
Quantity Length Item Description Part # Quantity Length Item Description Part #
4566 Ridge Dr NE • Salem, OR 97301 • F: 503-581-6877 • P: 503-581-8338 • www.taylormetal.com
Forgetting Anything? Underlayment? Screws? Clips? Caulking? Closures?
TAYLORM E T A L P R O D U C T S
Sold To: Order Contact:Phone #:Fax #:
□ Agricultural □ Residential □ Commerical Route:
□□□
ShadowLine**(circle): 1", or 1-1/2" 1/2" to 3" Reveal:
1"x12-5/8" SmoothWall**
1"x12-5/8" Lifetime Soffit**
Panels with ** need Pattern Choice: □Striations □Flat □1 V-Groove □2 V-GroovesPerforated?
12-3/8" Slim-Lock*16-1/4" Slim-Lock*12" MS-200*14-5/8" MS-200*16" MS-200*18" MS-200*12-3/4" MS-150*16-5/8" MS-150*20" MS-150*13-3/4" MS-100*17-5/8" MS-100*
□□□□□□□□□ □ □
12" Versa-Span*14-5/8" Versa-Span*16" Versa-Span*18" Versa-Span*15-1/2" T-Panel*
*All Kynar Slim-Lock, Easy-Lock, Lifetime Soffit, SmoothWall, ShadowLine, T-Panel, Versa-Span, CL-175, MS-100, MS-150, & MS-200 flashings are 10'*All ArmorTech StreamLine, T-3, Tuff Rib, GR7, PBR, HR-32, Marion "R", & Corrugated flashings are 12'6"
Flat not available on StreamLine
(Available on Lifetime Soffit Only)
( )Standard Panels are in Bold font.
Please provide a drawing for each flashing with precise measurements and anglesFax to: 503-581-6877
4566 Ridge Dr NE Salem OR 97301 • Phone: 503-581-8338 or 1-800-574-1388 • www.taylormetal.com
Custom Trim OrderTAYLORM E T A L P R O D U C T S
Custom Trim OrderTAYLORM E T A L P R O D U C T S
Drawing #:___ Pitch: _____ # of Pieces: ______________
Description: _____________________________________
Hems: □ Open □ Closed □ Slightly Open
Drawing #:___ Pitch: _____ # of Pieces: ______________
Description: _____________________________________
Hems: □ Open □ Closed □ Slightly Open
Drawing #:___ Pitch: _____ # of Pieces: ______________
Description: _____________________________________
Hems: □ Open □ Closed □ Slightly Open
Drawing #:___ Pitch: _____ # of Pieces: ______________
Description: _____________________________________
Hems: □ Open □ Closed □ Slightly Open
Please provide a drawing for each flashing with precise measurements and angles
www.taylormetal.com
Customer Name: Job Name:
Gauge: Color:
TAYLORM E T A L P R O D U C T S
QUALITY PRODUCTSEXCEPTIONAL SERVICE
SALEM BRANCH4566 Ridge Dr. NESalem, OR 97301
Office: 503-581-8338Toll Free: 1-800-574-1388
Fax: 503-581-6877
WOODINVILLE BRANCH5927 234th St. SE
Woodinville, WA 98072
Office: 425-485-3003Toll Free: 855-334-8558
Fax: 425-485-2710
SACRAMENTO BRANCH5711 Perrin Ave
McClellan, CA 95652
Office: 916-318-8844Toll Free: 1-800-574-1388
Fax: 916-993-4123
AUBURN BRANCH710 A. St. NW Suite 101
Auburn, WA 98001
Office: 206-900-9923Toll Free: 1-800-574-1388
Fax: 253-804-3545
RIVERSIDE BRANCH4880 Felspar St.
Riverside, CA 92509
Office: 323-407-7457Toll Free: 1-877-504-1594
Easy-Lock Installation Guide • ©2020 Taylor Metal ProductsRevised 6/20
top related