Measuring rates of reaction

Post on 23-Feb-2016

57 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

DESCRIPTION

Measuring rates of reaction. Measuring rates. The rate of a reaction is the rate of change of concentration with time . Δ C. Rate =. Where Δ = difference. Δ t. There are two ways of measuring the rate;. 1) The disappearance of a reactant. 2) The appearance of a product. - PowerPoint PPT Presentation

Transcript

Measuring rates of reaction

Measuring rates

The rate of a reaction is the rate of change of concentration with time.

Rate = ΔCΔt

Where Δ = difference

There are two ways of measuring the rate;

1) The disappearance of a reactant.

2) The appearance of a product.

Plot of the disappearance of a reactant.

0

0.5

1

1.5

2

2.5

3

0 20 40 60 80 100 120 140 160 180

time (min)

[246

tnba

] mol

/dm

3 x

10-4

Plot of the appearance of a product.

0

20

40

60

80

100

120

140

0 5 10 15 20 25

time (mins)

volu

me

(ml)

Using tangents to find rates.

At any given time the reaction rate can be calculated from the gradient of the tangent of the curve.

Δt

Δc

Gradient = ΔcΔt

Note how the rate decreases with time.

The slope of the curve is steeper at the beginning, when the rate is greater.

The curve becomes shallower as the rate decreases.

Measuring loss of mass

Some reactions can be followed by recording the mass at regular time intervals.

Eg; The reaction of calcium carbonate with acid.

The gas produced is lost lowering the mass.

Collecting gas

If a reaction produces a gas its volume can be measured at regular time intervals.

Eg; Hydrogen peroxide decomposes to form oxygen with a manganese dioxide catalyst.

An excess of marble chips were allowed to react with 100ml of 0.1 mol/dm3 HCl and the

gas collected;

• Plot these data, label as A.• On your graph sketch and explain the result

of repeating the experiment using;• B 50ml of 0.1mol/dm3 HCl with marble chips.• C 50ml of 0.2 mol/dm3 HCl with marble chips.• D 50ml of 0.1 mol/dm3 HCl with marble

powder. Assume volumes remain contstant.

Tmin

0 1 2 3 4 5 6 7 8 9 10 11 12 13

Vml

0 43 62 76 88 96 100 105 110 112 115 117 120 120

Measuring colour changes - colourimetry

• If one of the reactants, or products, is coloured the rate of reaction can be followed by the absorption or transmission of light.

• This is measured using a colourimetre. • Light of a particular wavelength

(colour) is passed through a substance onto a light sensitive cell.

ColorimetryThe concentration of a coloured substance can be measured using a colorimeter.

The sample is placed into a cuvette.

The wavelength is set.

The transmission or absorbance is read off the scale.

The sample is put into a cuvette.

The correct filter is choosen.

The machine is zeroed using a blank.

The absorption, or transmission, is read off the scale.

Colourimetry

• The filter should let through only the light that is absorbed by the coloured solution.

• Eg; A blue substance absorbs yellow light.

• Yellow is its complementary colour, and so a yellow filter must be used.

• Conversely for a yellow substance a blue filter is used.

• Similarly for a Green substance a magenta filter is used.

• For a Red substance a cyan filter.

Beer-Lambert’s Law• Colourimetry assumes that;• Absorbance ά concentration• But this is only true within certain

limits.• If the concentration is too high

absorbance will be independent.• To determine the limits of this

technique the absorbance at different concentrations must be plotted as a calibration curve.

A calibration curve

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

concentration (mol/dm3)

Abs

orba

nce

Absorbance ά concentration between 0 – 0.3 mol/dm3

Above 0.3 mol/dm3 absorbance is no longer ά conentration, so the solution has to be diluted until it will give an absorbance on the straight line.

Measuring conductivity

If a reaction involves different numbers of ions it can be followed by measuring the conductivity of the solution.

Destructive analysis

• Samples, known as aliquots, are removed from the reaction mixture at regular time intervals.

• The reaction is quenched (stopped)• Then either the concentration of a

product, or a reactant, is determined by titration.

• In the process reactant/product is destroyed.

Eg; The reaction between propanone and iodine catalysed by protons.

CH3COCH3 + I2 → CH2ICOCH3 + HI

Propanone, iodo

propanone and HI are all colourless.

Iodine is yellow/brown

[Iodine] can be analysed by titration against sodium thiosulphate., giving colourless products.

2S2O32- + I2 → S4O6

2- + 2I-

NB aliquots become increasingly paler as the reaction proceeds.

It is difficult to distinguish the end point so starch is used as an indicator.

So long as iodine is present the solution will be blue/black.

At the end point it will be colourless.

top related