Journal Club Presentation Organized by: DEPARTMENT OF NEONATOLOGY (NU – I) MMCH.

Post on 26-Dec-2015

214 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

Transcript

Journal Club Presentation

Organized by:

DEPARTMENT OF NEONATOLOGY(NU – I) MMCH

ChairpersonDr. Md. Anwar Hossain

MBBS, M Phil, MCPS (Pediatrics)FCPS (Pediatrics), MD (Neonatology)

Assistant ProfessorDepartment of Neonatology

Mymensingh Medical College

SpeakerDr. Md. Abu Taher

Assistant Registrar

Neonatology(U-1), MMCH

Title

Role of micro-ESR and I/T ratio in the early diagnosis of

Neonatal Sepsis.

Source: • Mymensingh Medical Journal

2009 Jan ; 18(1): 56-61

Authors: Walliullah SM, Islam MN, Siddika M, Hossain MA, Chowdhury AK.

Study period: 19 months

(15th March’05 –15th Octeber’06) Study place: Dhaka Shishu Hospital, Dhaka.

Objective of the study:

Objective of this study is to find out the sensitivity and specificity of Micro-ESR and I/T ratio separately and combined in early diagnosis of neonatal sepsis.

Introduction:

Septicemia is one of the major cause of neonatal mortality and morbidity.

Despite considerable progress in hygiene condition, introduction of newer antimicrobials , advanced techniques for early diagnosis of sepsis, supportive measures for critically ill neonates, sepsis remains one of the important cause of morbidity and mortality in this age group.

Cont..

Cont..

Globally about 130 million baby’s born every year .

Among them 4 million die in the first 4 weeks of life due to infection, prematurity, and perinatal asphyxia.

Cont.. Recognition of infection is difficult in most

infected neonates as clinical manifestations mimic other conditions like asphyxia , hypoglycemia , prematurity etc.

Combination of clinical and laboratory examination can be used, though their predictive accuracy , sensitivity and specificity are variable.

Cont.. No Single laboratory test has been found to

have enough specificity and sensitivity But combination of hematological profiles

shows high sensitivity and specificity. The gold standard for diagnosis of neonatal

septicemia is a positive blood culture. A positive blood culture is found in 10-60% of

neonatal sepsis cases.

Cont.. In developing countries like Bangladesh, blood

culture facilities are non- existent in the district hospitals and UHCs.

But TLC, DLC, PBF, can easily be done even in health centers.

Among the hematological profiles , the micro –ESR is a popular and simple screening test to detect neonatal sepsis and has been recognized as a valid investigation tool.

Cont.. Micro-ESR is also possible to be done as bed

side test by heparinized capillary tube which is not very costly and very small amount of blood is required.

In spite of simplicity it is not practiced routinely in our country due to less availability of heparinized capillary tube.

In this study a normal value of micro-ESR in 1st hours is calculated as age of baby in days plus 3 mm to maximum15 mm.

Cont.. Band cell count increases significantly beyond

normal range in new born babies with bacterial infection.

All band cells and cells less mature than the band cells were classified together as immature neutrophil.

Cont..

I/T Ratio: Immature to total neutrophil count ratio can be calculated from peripheral blood film.

Immature cell count more than 20% of total neutrophil count (that is I/T ratio >0.2) is a useful marker of bacterial infection in newborn.

Cont..

So micro ESR & I/T ratio can be done as a part of simple routine screening test for the early diagnosis of neonatal sepsis.

As a simple method the present study was carried out to assess the role of micro-ESR and I/T ratio in the early diagnosis of neonatal sepsis

Methods:

Study type:

Prospective cross sectional study

Study population: 110 neonates (definite sepsis 30,

probable

sepsis 50, control 30 )

Inclusion criteria :

For Case:Neonates present with: (one or more) Lethargy Reluctant to feed Abdominal distension Vomiting Respiratory distress Fever

Cont…

For Control: No sign symptom of sepsis but admitted due to

other problems like- Physiological Jaundice Delayed passage of urine Feeding problem

Exclusion criteria :

IDM Perinatal asphyxia Congenital cyanotic heart disease.

Result:

In this study out of 80 clinically suspected cases of neonatal septicemia:

30 positive blood culture were taken as definite sepsis

50 with negative blood culture but one or more abnormal hematological profiles suggestive of sepsis were taken as probable sepsis .

30 neonates with no signs and symptoms of septicemia were taken as control group.

Cont..

Out of 80 cases 51 (63.75%) were male , and 29(36.25%) were female.

Incidence of sepsis is higher in low birth weight neonates in comparison to normal birth weight neonates (67% in definite sepsis and 70% in probable sepsis are LBW ).

Table: 1 : Micro-ESR in cases and control

Micro ESR

ProbableSepsis No.(%)

Control No.(%)

Definite sepsis No.(%)

Definite sepsis vs Probablesepsis

Definite sepsis vs Control

>Normal20

(40%)02

(6.7%)19

(63.3%) P=0.043 P=0.001

Normal30

(60%)28

(93.3%)11

(36.7%) Chi = 4.09

Chi =21.17

Total 50 30 30

Table: 2 : I/T ratio in cases and control

I/T ratio

ProbableSepsis No.(%)

Control No.(%)

Definite sepsis No.(%)

Definite sepsis vs Probablesepsis

Definite sepsis vs Control

>0.222

(44%)02

(6.7%)21

(70%)P =0.001 P=0.001

<0.228

(56%)28

(93.3%)09

(30%)Chi =14.44

Chi =25.45

Total 50 30 30

Cont..

In this study more than normal level of micro-ESR was found:

63.3% in definite sepsis 40% in probable sepsis and also 6.7% in control

Which was statistically significant(P value <0.05).

Cont…..In this study I/T ratio was positive in: 70% cases of definite sepsis 44% cases in probable sepsis 6.7% in control

Which was statistically significant ( p value <.05).

Table-3: Sensitivity ,specificity, positive and negative predictive values of micro-ESR in

definite sepsis &probable sepsis.Test Defini

te sepsis

Probable

sepsis

Total

Sensitivity (%)

Specificity (%)

Accuracy (%)

PP V

(%)

NPV

(%)

>norma

l19 20 39

normal

11 30 41 63.3 60 61.3 48.7 73.2

total 30 50

Table-4: Sensitivity ,specificity, positive and negative predictive values of micro-ESR in definite

sepsis & control.test Definite

sepsiscontrol total Sensitivi

ty (%)Specificity y (%)

Accuracy (%)

PP V (%)

N PV (%)

>normal 19 02 21

Normal 11 28 39 63.3 93.3 78.3 90.5 71.8

total 30 30

Table-5: Sensitivity ,specificity, positive and negative predictive values of I/T ratio in definite sepsis & probable sepsis.test Defini

te sepsis

Probable sepsis

total

Sensitivity (%)

Specificit y (%)

Acuracy (%)

Pp V (%)

N PV (%)

>0.2 21 22 43

<0.2 9 28 37 70.0 56 61.3 48.8

75.7

total 30 50

Table-6: Sensitivity ,specificity, positive and negative predictive values of I/T ratio in definite sepsis & control.

test Definite sepsis

control

total

Sensitivity (%)

Specificit y (%)

Acuracy (%)

PP V (%)

N PV (%)

>0.2 21 02 23

<0.2 9 28 37 70.0 93.3 81.7 91.3

75.7

total 30 30

cont….When it was compared between definite

and probable sepsis sensitivity of micro-ESR was 63.3% ,specificity 60% and negative predictive value was 73.2% .

But When it was compared between definite sepsis and control specificity was high (93.3%) ,positive predictive value 90.5%

cont….When I/T ratio was compared

between definite and probable sepsis sensitivity was 70% ,specificity 56% and negative predictive value was 75.7% .

But When it was compared between definite sepsis and control specificity was high (93.3%) ,positive predictive value 91.3%.

Table7: Sensitivity, specificity, positive and negative predictive values of Combined Micro ESR and I/T ratio between

definite sepsis and Probable sepsis

Validity test

Sensitivity

Specificity

Accuracy

PPV NPV

Percentage

80.0 70.0 73.8 61.5 85.4

In this study sensitivity and specificity of combined micro-ESR and I/T ratio was 80% and 70% respectively, when compared between definite sepsis and probable sepsis.

Table 8: Sensitivity, specificity, positive and negative predictive values of Combined Micro ESR and I/T ratio between

definite sepsis and control

Validity test

Sensitivity

Specificity

Accuracy

PPV NPV

Percentage

83.3 96.7 90.0 96.2 85.3

In this study sensitivity and specificity of combined micro-ESR and I/T ratio was 83.3% and 96.7% respectively, when compared between definite sepsis and probable sepsis.

DiscussionAs tools for early diagnosis of neonatal

septicemia, micro-ESR and I/T ratio were analyzed in this study to see the role of these parameters in all the neonates of both cases and control groups .

The incidence of sepsis is higher in low birth weight neonates in comparison to normal weight babies . 67% of neonate in definite sepsis and 70% of neonate in probable sepsis group were of low birth weight. Nearly similar observation was mentioned by Bhakoo ON , Singh M (perinatal risk factors in neonatal bacterial sepsis. Indian J Pediatr. 1988;55:941-946.)

cont.. Common clinical features of sepsis were reluctant to

feed(96.7%),lethargy(73.3%), abdominal distention (70%), jaundice(50%) and hypothermia (40%). This observation was similar to the observations by Hoque MM ,Ahmed ASM N, Ahmed S, Chowdhury MAKA (Clinical manifestation and bacteriological profile of septicemia in preterm neonates :Experience from a tertiary level pediatric hospital . BJMSc 2004;10(1):29-33) and Chowdhury MAKA, Rahman MM, Karim AQMR (Characteristic of septicemia in newborne in Dhaka Shishu Hospital.DSHJ.1998:14(2):9-12)

Study Sensitivity

Specificity

In this study : I/T ratio

70% 56%

70% 93.3%

Micro – ESR

63.3% 60%

63.3% 93.3%

Combination of Micro- ESR &I/T ratio

80% 70%

83.3% 96.7%

Misra et al : I/T ratio Micro- ESR (> 8mm)

92% 79%

75% 85%

Sharma et al : I/T ratio Micro-ESR (> 10mm)

60% 62.5%

66.7% 70%

Okolo et al : I/T ratio Micro-ESR

96.9% 90%

84.5% 85%

Sing et al : Micro-ESR (> 14mm)

55% 82%

Chandana et al : I/T ratio

-- 31%

cont..In this study for Micro-ESR

Sensitivity and Specificity of Micro-ESR in definite sepsis was 63.3% and 60% respectively . Misra et al. showed high sensitivity (79%) and specificity (92%). Sharma et al. Showed Micro ESR was relatively low sensitivity (60%) and specificity (62.5%).Okolo et al. showed high sensitivity 96.9% and specificity 90%

cont..In this study sensitivity and specificity of

I/T ratio in definite sepsis was 80% and 70% respectively. . Misra et al. showed high sensitivity (92%) and specificity (79%). Sharma et al. Showed Micro ESR was relatively low sensitivity (60%) and specificity (62.5%).Sing et al. observed low specificity 48%.Chandna et al. showed specificity was much lower 31%

cont..In this study sensitivity and specificity of

combined micro-ESR and I/T ratio was 80% and 70% respectively. Misra et al. showed sensitivity 75% and specificity 85%. Sharma et al. Showed relatively low sensitivity 66.7% and specificity 70%. Okolo et al. showed high sensitivity 84.4% and specificity 85%.

Limitations:1. This study is a single hospital based study.

2. Sample size is small.

Key message:

Micro-ESR and I/T ratio can be used as reliable test in the early diagnosis of neonatal sepsis with high degree of sensitivity and specificity specially where blood culture facility is not available .

top related