ITE, ITC, CIC - AudibelPro · PDF fileRange ITE, ITC and CIC fitting range. 0 10 20 30 40 50 60 70 80 90 100 110 120 250 500 1K 2K 4K 8K. Title: Range ITE, ITC, CIC Spec Sheet - Audibel
Post on 12-Feb-2018
215 Views
Preview:
Transcript
* Sarampalis, A., Kalluri, S., Edwards, B., Hafter, E. (2009, October). Objective measures of listening effort: Effects of background noise and noise reduction. Journal of Speech, Language, and Hearing Research, 52, 1230-1240.
FeaturesSound ImagingRange Platinum
Optimal high-resolution sound imaging with frequency shaping in all 16 channels and 16 bands
Range Gold High-resolution sound imaging with frequency shaping in 12 channels and 12 bands
Range Silver Frequency shaping in 8 channels and 8 bands
Binaural Spatial Mapping Available in Range Platinum and Gold. This innovative protocol queries, analyzes, and maps the acoustic space surrounding the patient, applying the appropriate signal processing strategy for directionality and noise management.
Active Noise Control2 nearly doubles the noise reduction capability of our leading noise reduction and speech preservation system while still maintaining speech. Active Noise Control2:
• Instantly applies variable noise adaptation in all channels between each pause
• Has been proven to reduce listening effort and cognitive fatigue when used in tandem with Superior Speech Locator*
• Provides up to 20dB of noise reduction
Active Frequency Control This new frequency lowering technology is a smart solution for patients who have steeply sloping, high-frequency hearing loss. It is designed to enhance real-time audibility by intelligently identifying high-frequency speech cues – then replicating them in lower frequencies.
Sound Enhancements Our signal processing architecture has been updated to enhance the overall sound quality and efficiency of Range hearing aids, including new vent modeling, automatic vent detection, improved compression and updated eSTAT targets.
Active Noise Control Boost Activated via SurfLink™ Remote, this feature allows patients to enable aggressive noise reduction while optimizing sound quality in extremely noisy situations.
Self Learning gradually and automatically learns patient volume control preferences in each active memory, which helps reduce the number of manual volume control adjustments patients need to make.
Whistle Feedback Cancellation This leading technology ensures wide fitting ranges and a fast response to more complex feedback.
HydraShield®2 Audibel’s proprietary moisture protection system integrates a new oleophobic nano-coating designed to better protect hearing aids from earwax and other oily substances making Range more reliable and durable than ever before.
T2 Remote allows your patients to control their hearing aid for memory or volume adjustments using any cell or touch-tone phone, avoiding the need to carry additional hardware.
Swap Fit fitting function allows you to transfer patient settings from their current Audibel product to a new one — enabling more time for fine-tuning and counseling.
Synchronized User Adjustments Patients can use a single hearing instrument to adjust volume or memory for the pair — eliminating the need to manually change two instruments.
Binaural Telephone Mode places the phone-side hearing aid in Automatic Telephone Response or Telecoil mode while attenuating the off-side hearing aid.
Live Real Ear Measurement Combined with the power of Inspire® fitting software, it lets you see the hearing aid output in your patient’s ear in real-ear SPL.
Live Speech Mapping verifies hearing aid’s processing of speech, or any live acoustic input, in real time through a 3D display.
Voice Indicators alert your patients to the status of their hearing aid, low battery, memory and telephone modes in their choice of male or female voices in a wide variety of languages.
Automatic Telephone Solutions (ATS) automatically detects telephone use and adjusts to the optimal acoustic frequency response for telephone listening.
Leisure Listening Memories
• TV memory program designed for optimal performance while watching television
• Multiple music genre settings designed to maximize sound quality and listening enjoyment
Bring the benefits of telehealth to your practice with our On Demand options. Each one is designed to elevate your interaction with patients and provide a better way for you to deliver care. Includes T2 On Demand, Audiology On Demand™ and innovative applications that work with the iPad®, iPhone® and iPod® Touch.
SurfLink Accessories
• SurfLink Programmer gives you the ultimate speed and flexibility in wireless programming.
• SurfLink Media allows patients to wirelessly connect to virtually any media device with no pairing or body-worn device required.
• SurfLink Remote provides patients with a way to adjust their hearing instruments discreetly and easily.
Auto Path
• Automatic fitting routine
• Provides an accurate and efficient first fit
Verify Comfort
In-Situ Audiometry
Data Logging
Programming InformationPreferred Method:
– Wireless programming using SurfLink Programmer
– Battery in
Alternative Method:– Purple programming cable +
orange flex strip
– Battery in or out
ITE, ITC, CICPlatinum | Gold | Silver
Audibel • 6700 Washington Avenue South • Eden Prairie, MN 55344
SPEC0092-00-EE-AB © 2011 Audibel All Rights Reserved 10/11
Measurement Conditions and Recommendations
The data for Range are obtained and performance is expressed according to ANSI S3.22 (2003), ANSI S3.7 (1995), ANSI C63.19 (2007), IEC 60118-7 (2005), IEC 60711 (1981), DIN 45605 (1989) and IEC 60118-0 (1983) with Amendment 1 (1994-01). The Audibel proprietary Real Time Analyzer and the Audibel Automated Design Verification Test System comprise the basic test equipment. Data may be subject to change with product refinement.
Because of the adaptive signal processing capabilities of Range hearing instruments, the hearing instrument must be set to test mode to compare the actual performance of the hearing instrument with these specifications. Range hearing instruments may be set to test mode with Inspire® by reading the hearing aid and selecting the “Hearing Aid Test” screen from the menu on the left side of the Inspire window, then selecting the “Full on Gain” button.
Measurement
ITE
ANSI/IEC 2cc
Coupler
IEC OES Coupler
Peak OSPL90 (dB SPL) 115-123 124-130
HFA OSPL90 (dB SPL) 110-116 NA
RTF OSPL90 (dB SPL) NA 116-128
Peak Gain (dB) 50-60 58-68
HFA Full-On Gain (dB) 46-53 NA
RTF Full-On Gain (dB) NA 54-66
Frequency Range (Hz) 100-5000 100-5100
Reference Test Frequency (kHz) NA 1.6
HFA Frequencies (kHz) 1.0, 1.6, 2.5 NA
Reference Test Gain (dB) 33-39 41-53
Harmonic Distortion
500 Hz (%) <3 < 3
800 Hz (%) <3 < 3
1600 Hz (%) <3 < 3
Attack and Release Time (ANSI/IEC) – Test Mode
Attack Time (ms) 20 20
Release Time 0.1s (ms) 5 - 150 5 - 250
Release Time 2.0s (ms) 5 - 150 5 - 250
Induction Coil Sensitivity
HFA SPLITS (ANSI) (dB SPL) 95-101 NA
MASL (IEC) (dB SPL) NA 83-95
ANSI/IEC Battery Current (mA) 1.22 1.22
Idle Current (mA) 1.13-1.15 1.13-1.15
Estimated Battery Life for 16-Hour Day
13 Zinc Air (days) 12-16 12-16
312 Zinc Air (days) NA NA
10 Zinc Air (days) NA NA
ITC
ANSI/IEC 2cc
Coupler
IEC OES Coupler
110-115 119-124
105-109 NA
NA 111-116
40-50 49-58
36-46 NA
NA 43-53
100-6500 100-6800
NA 1.6
1.0, 1.6, 2.5 NA
28-32 36-41
<3 < 3
<3 < 3
<3 < 3
20 20
5 - 150 5 - 250
5 - 150 5 - 250
89-94 NA
NA 71-82
1.22 1.22
1.15 1.15
NA NA
8-9 8-9
NA NA
CIC
ANSI/IEC 2cc
Coupler
IEC OES Coupler
110-115 119-124
104-110 NA
NA 110-115
40-50 49-58
35-46 NA
NA 43-54
100-7500 100-7600
NA 1.6
1.0, 1.6, 2.5 NA
28-32 35-40
<3 < 3
<3 < 3
<3 < 3
20 20
5 - 150 5 - 250
5 - 150 5 - 250
NA NA
NA NA
1.17 1.17
1.12-1.13 1.12-1.13
NA NA
NA NA
4-6 4-6
ANSI/IEC DATA
ITE, ITC, CICPlatinum | Gold | Silver
FO
G 5
0 (
dB
)
OS
PL
90
(d
BS
PL
)
Frequency (Hz)
FOG 50OSPL90
70
80
90
100
110
120
10
20
30
40
50
60
100 1000 10000
Wi Series RIC13 40 – 2cc
OSPL90 (green) and Full-On Gain (gray) curves for the Range ITE at the highest matrix of 123/60.
FO
G 5
0 (
dB
)
OS
PL
90
(d
BS
PL
)
Frequency (Hz)
FOG 50OSPL90
70
80
90
100
110
120
10
20
30
40
50
60
100 1000 10000
Wi Series RIC13 40 – 2cc
OSPL90 (green) and Full-On Gain (gray) curves for the Range ITC at the highest matrix of 115/50.
FO
G 5
0 (
dB
)
OS
PL
90
(d
BS
PL
)
Frequency (Hz)
FOG 50OSPL90
70
80
90
100
110
120
10
20
30
40
50
60
100 1000 10000
Wi Series RIC13 40 – 2cc
OSPL90 (green) and Full-On Gain (gray) curves for the Range CIC at the highest matrix of 115/50.
Range ITE, ITC and CIC fitting range.
0
10
20
30
40
50
60
70
80
90
100
110
120
250 500 1K 2K 8K4K