Transcript
ESTUDIO DE DETERMINACIN DE LA POTENCIA EFECTIVA Y RENDIMIENTO EN LA CENTRAL TRMICA DE INDEPENDENCIA
Informe Final
UNIDADES: WARTSILA 1, WARTSILA 3
COMBUSTIBLE: GAS NATURAL
Elaborado por
OCTUBRE 2014
HOJA DE RUTA DEL INFORMEVersinFechaDestinoMotivoFecha de Resultado de la Revisin
ObservadoAprobado
A16/10/2014 EGESURRevisin
B
C
D
TABLA DE CONVERSION DE UNIDADES AL SISTEMA DE UNIDADES INTERNACIONALtemSistema Internacional de UnidadesEquivalencias en otras unidades
1Temperatura
2Energa
3Volumen
4Presin
5Masa
Estudio de Determinacin de la Potencia Efectiva y Rendimiento en la Central Trmica de Independencia
NDesignacinCombustibleConfiguracinFecha de EnsayoNDesignacinCombustibleConfiguracinFecha de Ensayo
1CT - IndependenciaGas NaturalWartsila 121/09/20142CT - IndependenciaGas NaturalWartsila 322/09/2014
InformeEmpresa GeneradoraEmpresa ConsultoraVeedor
VersinFinalEGESURHAMEKCOES
CONTENIDO GENERAL
1.INFORMACIN GENERAL91.1.DESCRIPCIN DE LA EMPRESA91.2.DESCRIPCIN DE LA CENTRAL TRMICA DE INDEPENDENCIA Y LAS UNIDADES ENSAYADAS92.OBJETIVO DE LOS ENSAYOS102.1.ENSAYOS DE POTENCIA EFECTIVA102.2.ENSAYOS DE RENDIMIENTO103.CRONOGRAMA DE LOS ENSAYOS104.PARTICIPANTEs EN LOS ENSAYOS Y ORGANIZACIN DEL PERSONAL115.PREPARACIN DE LAS PRUEBAS126.PUNTOS DE MEDICIN E INSTRUMENTACIN UTILIZADA136.1.PUNTOS DE MEDICIN136.2.VARIABLES MEDIDAS E INSTRUMENTOS DE MEDICIN147.PROCEDIMIENTO DE LAS PRUEBAS158.ANLISIS DE COMBUSTIBLE169.METODOLOGA DE CLCULO1610.DATOS REGISTRADOS1810.1.DATOS REGISTRADOS A PLENA CARGA1810.2.DATOS REGISTRADOS PARA CARGAS PARCIALES2011.VALIDACION DE DATOS2812.DATOS VALIDADOS3013.CALCULOS Y RESULTADOS3213.1.POTENCIA EFECTIVA3213.2.RENDIMIENTO Y OTROS NDICES RELACIONADOS AL CONSUMO DE COMBUSTIBLE34
APNDICES
APNDICE A:ACTAS DE ENSAYOS.APNDICE B:INFORMACIN COMPLEMENTARIA.APNDICE C:INFORMACIN DE CONDICIONES AMBIENTE.APNDICE D:RESULTADOS DE ANLISIS DE LABORATORIOAPNDICE E:METODOLOGIA Y VALIDACIN.APNDICE F:CUADROS DE CLCULO.CONTENIDO DE CUADROS
CUADRO 11: CARACTERSTICAS TCNICAS DE LOS GRUPOS ELECTROGENOS9CUADRO 31: CRONOGRAMA DE LOS ENSAYOS REALIZADOS10CUADRO 32: CRONOGRAMA DE LOS ENSAYOS REALIZADOS10CUADRO 33: DURACIN DE LOS ENSAYOS Y FRECUENCIA DE MEDICIONES11CUADRO 51: ACTIVIDADES PREPARATORIAS PARA LAS PRUEBAS12CUADRO 61: VARIABLES E INSTRUMENTOS DE MEDICIN UTILIZADOS14CUADRO 71: PROCEDIMIENTO DE PRUEBAS15CUADRO 81: DATOS DE COMBUSTIBLE GAS NATURAL16CUADRO 101: DATOS DE ENSAYO DE LA UNIDAD WARTSILA 01 (POTENCIA EFECTIVA)18CUADRO 102: DATOS DE ENSAYO DE LA UNIDAD WARTSILA 03 (POTENCIA EFECTIVA)19CUADRO 103: DATOS DE ENSAYO PARA 4.0 MW (WARTSILA 01)20CUADRO 104 : DATOS DE ENSAYO PARA 3.0 MW (WARTSILA 01)21CUADRO 105 : DATOS DE ENSAYO PARA 2.0 MW (WARTSILA 01)22CUADRO 106 : DATOS DE ENSAYO PARA 1.5 MW (WARTSILA 01)23CUADRO 107: DATOS DE ENSAYO PARA 4.0 MW (WARTSILA 03)24CUADRO 108: DATOS DE ENSAYO PARA 3.0 MW (WARTSILA 03)25CUADRO 109 : DATOS DE ENSAYO PARA 2.0 MW (WARTSILA 03)26CUADRO 1010 : DATOS DE ENSAYO PARA 1.5 MW (WARTSILA 03)27CUADRO 111 : VALIDACION DE DATOS (WARTSILA 01)28CUADRO 112: VALIDACION DE DATOS (WARTSILA 03)29CUADRO 121: DATOS VALIDADOS DE LA UNIDAD WARTSILA 01 (POTENCIA EFECTIVA)30CUADRO 122: DATOS VALIDADOS DE LA UNIDAD WARTSILA 03 (POTENCIA EFECTIVA)31CUADRO 131: CLCULO DE LA POTECIA EFECTIVA (Wartsila 01)32CUADRO 132: POTENCIAS DE ENSAYO, ISO Y EFECTTIVA (Wartsila 01)33CUADRO 133: CLCULO DE LA POTECIA EFECTIVA (Wartsila 03)33CUADRO 134: POTENCIAS DE ENSAYO, ISO Y EFECTTIVA (Wartsila 03)34CUADRO 135: RESULTADOS DE RENDIMIENTO, CONSUMO, EFICIENCIA34CUADRO 136: RESULTADOS DE RENDIMIENTO, CONSUMO, EFICIENCIA35CUADRO 137: RESULTADOS DE LOS NDICES DE CONSUMO (Wartsila 01)37CUADRO 138: RESULTADOS DE LOS NDICES DE CONSUMO (Wartsila 03)39CUADRO 139: RENDIMIENTO Y OTROS INDICES RELACIONADOS AL CONSUMO41CUADRO 1310: RENDIMIENTO Y OTROS INDICES RELACIONADOS AL CONSUMO41
CONTENIDO DE FIGURASGRAFICO 41: PARTICIPANTES Y ORGANIZACIN DEL PERSONAL11GRAFICO 61: PUNTOS DE MEDICION13GRAFICO 62: IMGENES DE LOS INSTRUMENTOS DE MEDICION UTILIZADOS14
RESUMEN EJECUTIVO1. ANTECEDENTESHAMEK Ingenieros Asociados S.A.C, por encargo de la empresa EGESUR y acorde con los alcances que se estipulan en el Procedimiento PR-17 del COES SINAC Determinacin de la Potencia Efectiva y Rendimiento de las Centrales Termoelctricas y tomando en cuenta las consideraciones establecidas en el Procedimiento N 17 del COES SINAC, ha elaborado el presente informe Determinacin de la Potencia Efectiva y Rendimiento en la Central Trmica INDEPENDENCIA; que tiene por objeto presentar los resultados de los clculos de potencia efectiva y rendimiento de esta central, que han sido desarrollados en base a los ensayos efectuados el da 21/09/2014 y 22/09/20142. DATA BSICA Y METODOLOGA DE CLCULO APLICADA2.1Data bsica1. Registros de los ensayos.- se ha medido los siguientes datos: Potencia en bornes del generador Potencia en auxiliares Temperatura ambiente Presin ambiente Consumo de combustible2. Establecimiento de las condiciones de potencia efectiva y de referenciaSegn las definiciones establecidas en el Procedimiento PR-17 se ha establecido las condiciones de potencia efectiva; asimismo de acuerdo a la Norma ISO 3046-1, se ha establecido las condiciones de referencia; los mismos que se muestran en la siguiente Tabla N 1. TABLA N 1CONDICIONES DE POTENCIA EFECTIVA Y DE REFERENCIA
PARMETROS AMBIENTALESUNIDADCONDICIONES DE POTENCIA EFECTIVA (1)CONDICIONES DE REFERENCIA (2)
Temperatura C25.825
Humedad relativa%81.160
Presin kPa98.59101.3
1. Las condiciones de potencia efectiva han sido definidas en funcin a los datos obtenidos de SENAMHI: Estacin HACIENDA BERNALES, informacin de GPS y como indica en el CAPTULO 9, Metodologa de Clculo. 2. Estas condiciones de referencia son las que fijan la norma ISO 3046 -1.
3. Poder Calorfico y Densidad del combustible utilizado
TABLA N 2CARACTERSTICAS DEL GAS NATURAL(21/09/2104)
DESCRIPCINUNIDADESVALOR PROMEDIO[footnoteRef:1] [1: Estos valores son referenciales.]
Poder Calorfico InferiorMJ/m336.172
Densidad relativa0.609
TABLA N 3CARACTERSTICAS DEL GAS NATURAL(22/09/2014)
DESCRIPCINUNIDADESVALOR PROMEDIO[footnoteRef:2] [2: Estos valores son referenciales.]
Poder Calorfico InferiorMJ/m336.168
Densidad relativa0.609
2.2MetodologaTodos los clculos han sido efectuados mediante la aplicacin en MatLab HAMEK_POTRENCT_2014 diseado por HAMEK Ingenieros Asociados S.A.C., especficamente para calcular la potencia efectiva y rendimiento de unidades trmicas segn alcances del Procedimiento PR-17 del COES SINAC. En sntesis, la metodologa parte por un proceso de validacin de datos para luego continuar con clculos de la potencia y Heat Rate primero a condiciones de referencia y luego a condiciones de potencia efectiva; para lo cual se parte de los datos de ensayo y se aplican las correcciones por los diferentes parmetros que se indican en la siguiente tabla:TABLA N 4VARIABLES DE CORRECCIN DE POTENCIA Y CONSUMO ESPECFICO DE COMBUSTIBLE CONSIDERADOS
VARIABLES DE CORRECCINPOTENCIACONSUMO ESPECFICO DE COMBUSTIBLE
Temperatura ambiente
Humedad relativa
Presin ambiente
1) Proceso de validacin de datos de ensayo.- consisti en eliminar todas las mediciones de potencia que superan 2 K de la temperatura ambiente[footnoteRef:3] y/o 3 % de la potencia promedio[footnoteRef:4]. Para las pruebas de rendimiento no se tiene establecido esta consideracin porque no existe una referencia en el procedimiento PR-17, tampoco en las normas internacionales. [3: Acorde con el Procedimiento PR-17 del COES (Condiciones particulares de estabilidad para un grupo de generacin)] [4: Condicin no especificada en el Procedimiento PR-17, por lo que este valor se ha tomado de la Norma Internacional ISO 15550-2002.]
2) Clculo de la potencia efectiva, la cual ha sido efectuada segn se explica a continuacin: a) Primeramente se lleva todos los datos vlidos de la potencia de ensayo (POTy) a las condiciones de potencia de referencia ISO (POTr).b) Luego se lleva todos los datos de potencia calculados a las condiciones de referencia (POTr) a las condiciones de potencia efectiva (POTx).3) Clculo del rendimiento, la cual ha sido efectuada segn se explica a continuacin: a) Definicin del parmetro bsico: El parmetro bsico que se ha considerado es el consumo especfico de combustible, de acuerdo a la norma ISO 3046-1:2002b) Clculo del consumo especfico, rendimiento, Heat Rate (consumo especfico de calor) y eficiencia. En primer lugar, con los datos de consumo de combustible de ensayo (m3/h) y la potencia (kW), se determina el consumo especfico de combustible (m3/kWh) en condiciones de ensayo a las condiciones de referencia y luego a las condiciones de potencia efectiva. Finalmente considerando el Poder Calorfico Inferior del combustible utilizado, cuyo resultado se encuentra en el ANEXO D, se ha determinado el Heat Rate o consumo especfico de calor (BTU/kWh) y la eficiencia en %.
3. RESULTADOS3.1 Potencia Efectiva de la CT INDEPENDENCIATABLA N 5POTENCIA EFECTIVA DE LAS UNIDADES WARTSILA 01 Y 03UnidadPOTENCIA DE ENSAYO POTy (KW)POTENCIA DE REFERENCIA POTr (KW)POTENCIA DE SITIO POTx (KW)POTENCIA DE SSAA (KW)
Wartsila 015714.355714.355714.35306.696
Wartsila 035715.925715.925715.92306.879
3.2 Rendimiento de la CT INDEPENDENCIA
TABLA N 6RENDIMIENTO Y OTROS NDICES RELACIONADOS AL CONSUMO DE COMBUSTIBLEUnidadCarga nominal (MW)Potencia Efectiva Heat Rate o Consumo especfico de calorConsumo de CombustibleRendimientovolumtricoConsumo especfico de combustibleEficiencia
(kW)BTU/kWh(m3/h)(kWh/m3)(m3/kWh)(%)
Wartsila 015,75714,357924,01320,74,330,231143,1
43848,399224,81035,53,720,269138,3
32975,309251,2802,83,710,269836,9
21982,3110393,0600,93,300,303132,8
1,51486,5312191,4528,62,810,355628,0
Wartsila 035,75715,928135,91356,64,210,237342,0
43984,858590,1998,53,990,250639,7
32980,909132,0794,13,750,266437,4
21988,4910721,5621,93,200,312731,8
1,51491,9812395,3539,52,770,361627,5
1. INFORMACIN GENERALDESCRIPCIN DE LA EMPRESALa Central Trmica Independencia, se encuentra ubicada en el distrito de Independencia, provincia de Pisco, departamento de Ica, tiene una potencia instalada de 22,9 MW, esta conformador por cuatro grupos alternantes (ciclo otto) de 5,73 MW cada uno, que utilizan gas natural como combustible nico.
DESCRIPCIN DE LA CENTRAL TRMICA DE INDEPENDENCIA Y LAS UNIDADES ENSAYADASLa C.T. INDEPENDENCIA est conformada por 4 motores disel, de los cuales se realizaron las pruebas a las unidades WARTSILA 1 y WARTSILA 3, en el siguiente cuadro se muestra las especificaciones tcnicas de las unidades wartsila mencionadas. CUADRO 11: CARACTERSTICAS TCNICAS DE LOS GRUPOS ELECTROGENOS
DATOS DE GENERADOR
Nombre CentralUnidad WARTSILA 1Unidad WARTSILA 3
FabricanteABBABB
MarcaABBABB
TipoHSG 900 XU 10AMG 0900 XU 11
Ao Fabricacion19941998
N Serie45481114561878
Velocidad(RPM)720720
Sistema de RefrigeracionAireAire
Pot. Aparente_MVA88
Pot. Nominal_MW6.46.4
Pot. Efectiva_MW6.1196.265
Tensin Salida_KV10.510.5
Intensidad_Amp.439445
Factor Potencia0.80.8
Frecuencia6060
Numero de fases33
Tipo de conexinYnYn
Estado ActualOperativoOperativo
5. OBJETIVO DE LOS ENSAYOS2.1. ENSAYOS DE POTENCIA EFECTIVAEstos ensayos tienen por objeto contar con toda la informacin necesaria para calcular la potencia efectiva de la central trmica bajo condiciones de estabilidad requeridas. Durante los ensayos se ha medido los siguientes parmetros: Potencia en bornes del generador. Presin ambiente. Temperatura ambiente.
2.2. ENSAYOS DE RENDIMIENTOEn este caso, para la determinacin del rendimiento se ha considerado la medicin de los siguientes parmetros: Potencia en bornes del generador. Presin ambiente. Temperatura ambiente. Consumo de combustible.
6. CRONOGRAMA DE LOS ENSAYOSDe acuerdo a las coordinaciones previas establecidas entre las tres partes se desarroll el siguiente programa general de ensayos: CUADRO 31: CRONOGRAMA DE LOS ENSAYOS REALIZADOS PARA LA UNIDAD WARTSILA 1
CARGA NOMINALFECHAHORA DE INICIOHORA DE FINALIZACIN
5.7 MW21/09/201401:3006:30
4.0 MW06:4507:15
3.0 MW07:3008:00
2.0 MW08:1508:45
1.5 MW09:0009:30
CUADRO 32: CRONOGRAMA DE LOS ENSAYOS REALIZADOS PARA LA UNIDAD WARTSILA 3
CARGA NOMINALFECHAHORA DE INICIOHORA DE FINALIZACIN
5.7 MW22/09/201401:1506:15
4.0 MW06:3007:00
3.0 MW07:1507:45
2.0 MW08:0008:30
1.5 MW08:4509:15
Dentro de este cronograma general se ha considerado los siguientes tiempos y frecuencia de mediciones: CUADRO 33: DURACIN DE LOS ENSAYOS Y FRECUENCIA DE MEDICIONES
UNIDADCARGA NOMINAL (%)DURACIN DE PRUEBAFRECUENCIA DE REGISTRO DE DATOS
WARTSILA 1 Y 35.7 MW5 horas10 min.
4.0 MW30 min.01 min.
3.0 MW
2.0 MW
1.5 MW
7. PARTICIPANTEs EN LOS ENSAYOS Y ORGANIZACIN DEL PERSONAL
Durante los ensayos han participado, el representante de EGESUR, un representante del COES y el Jefe de Ensayo de la CONSULTORA con todo su equipo que se han organizado como se indica en el siguiente grfico.
GRAFICO 41: PARTICIPANTES Y ORGANIZACIN DEL PERSONAL
8. PREPARACIN DE LAS PRUEBASCUADRO 51: ACTIVIDADES PREPARATORIAS PARA LAS PRUEBAS DE LA UNIDAD WARTSILA 1 y 3TEMACTIVIDADESWARTSILA 1WARTSILA 3
FECHAHORAFECHAHORA
1Reunin de trabajo inicial con representante de EGESUR21/09/201421:0022/09/201421:00
2Recorrido de la central trmica para verificar estado operativo de las unidades y puntos de medicin.21/09/201421:3022/09/201421:30
3Instalacin de los instrumentos de medicin: registradores de parmetros elctricos, ambientales y mecnicas (flujo). 21/09/201422:0022/09/201422:00
4Apertura del Acta con presencia del Rep. EGESUR, el Jefe de Ensayo de HAMEK y el Rep. de COES.21/09/201423:0022/09/201423:00
5Acuerdos y consideraciones previas a los ensayos: Duracin de las pruebas. Frecuencia de las mediciones a plena carga.21/09/201423:3022/09/201423:30
6Definicin de cronogramas de ensayo definitivos22/09/201400:3021/09/201400:30
9. PUNTOS DE MEDICIN E INSTRUMENTACIN UTILIZADA6.1. PUNTOS DE MEDICINGRAFICO 61: PUNTOS DE MEDICION
23
1.21.1
NEquipoModelo SerieVariable
1Analizador de redes1.1 PQ Box 1001203-105Potencia, fdp de generacin a 10,5 kV
1.2 RPM-16501650-10681Potencia, fdp de los SSAA a 10,5 kV
2Flujmetro ultrasnicoPT878GC-01PT878GC-01-1076Flujo y totalizador de combustible consumido
3Estacin meteorolgicaDavis Vantage VueD101025a007Presin y temperatura bulbo seco ambiente.
6.2. VARIABLES MEDIDAS E INSTRUMENTOS DE MEDICINCUADRO 61: VARIABLES E INSTRUMENTOS DE MEDICIN UTILIZADOS EN LAS PRUEBAS DE LA C.T. INDEPENDENCIAVARIABLES A MEDIRPUNTO DE MEDICININSTRUMENTO DE MEDICIN
Elctricas: potencia activa, potencia reactiva, energa activa, energa reactiva; factor de potencia, corriente y tensin.Bornes de generacin a nivel de 10.5 kV
01 Analizador Electrnico Porttil de Redes Elctricas:Marca Aeberle, Modelo PQ-box, Serie 1203 105. Para el bloque A
01 Analizador Electrnico Porttil de Redes Elctricas:RPM, Modelo 1650 Serie 1650 - 10681. Para el bloque B.
Ambientales: Temperatura, humedad relativa y presin ambiente.Ambiente, rea cercana a la zona de admisin de aire en zona central de distribucin de grupos.01 Estacin meteorolgica porttil, marca DAVIS.Serie: D101025A007
Mecnicas: Flujo de combustibleManifold de alimentacin de combustible para las unidades01 Medidor de flujo ultrasnico, Marca: TRANSPORT PT878GC-01-1076Serie: PT878GC-01-1076
GRAFICO 62: IMGENES DE LOS INSTRUMENTOS DE MEDICION UTILIZADOS ANALIZADOR DE REDES PORTTIL PQBOX-100 EN LA UNIDAD W-01ANALIZADORES EN SSAA Y BORNES DE GENERACIN
MEDICION DE FLUJO ESTACIN METEOROLGICA PORTTIL
10. PROCEDIMIENTO DE LAS PRUEBASLuego de las actividades previas descritas en el captulo 5, se desarrollaron los ensayos de potencia efectiva y rendimiento de las unidades segn el cronograma general que se indica en captulo 3 (Ver detalles en el Apndice A - Acta de Ensayo).En cada unidad los ensayos han tenido el siguiente procedimiento general que se indica en la siguiente tabla.
CUADRO 71: PROCEDIMIENTO DE PRUEBASNACTIVIDADPARTICIPAN
1Instalacin del personal de HAMEK en los puntos de medicin y verificacin de la operatividad de los instrumentos correspondientes.Todo el personal de HAMEK
2Verificacin de operatividad de las unidades a ensayarRep. del COES, Rep. De EGESUR y Jefe de Ensayos de HAMEK.
3Verificacin de la instalacin y operatividad de los equipos de medicinRep. De EGESUR, Rep. Del COES y Jefe de Ensayos de HAMEK.
4Indicacin del inicio de las pruebas al operador de la unidad en prueba.Jefe de Ensayos, Rep. de EGESUR, Rep. Del COES y el operador de la unidad.
5Medicin de parmetros elctricos, ambientales y de consumo de combustible, segn cronograma.Personal de HAMEK.
6Toma de muestras de combustiblePersonal de HAMEK y EGESUR
7Descarga de registros de los instrumentos de medicin utilizados.Personal de HAMEK
8Desmontaje de los instrumentos de medicinPersonal de HAMEK
9Procesamiento de InformacinPersonal de HAMEK
10Cierre del Acta de ensayos y suscripcin de las mismas.Jefe de Ensayo de HAMEK, Rep. De EGESUR y Rep. del COES
11. ANLISIS DE COMBUSTIBLEPara el clculo de la eficiencia y el consumo especfico de calor se considera el poder calorfico bajo del combustible LHV y la densidad. Que es determinado como el promedio del resultado de poder calorfico y densidad que resulta de analizar dos muestras de combustible tomadas primero al inicio de las pruebas da 21-09-2014 y segundo antes de finalizar las pruebas 22-09-2014 como indica el PR-17 del COES.CUADRO 81: DATOS DE COMBUSTIBLE GAS NATURAL[footnoteRef:5] [5: Se adjunta los resultados del anlisis de combustible en el APNDICE D.]
DescripcinUnidadesValor Promedio[footnoteRef:6] [6: Estos valores son referenciales]
Poder Calorfico inferior(21/09/2014)[kJ/m3]36 172
Poder Calorfico inferior(22/09/2014)[kJ/m3]36 168
Densidad Relativa0.609
12. METODOLOGA DE CLCULOTomando en cuenta la cantidad de datos a procesar y muchas de ellas repetitivas e iterativas, HAMEK Ingenieros Asociados S.A.C., ha diseado la aplicacin HAMEK_POTREN_2013 en MatLab, exclusivo para calcular la potencia efectiva y rendimiento de unidades trmicas a partir de datos de ensayo, datos tcnicos de las unidades, caractersticas del combustible utilizado y frmulas consideradas en la Norma ISO 3046-1:2002 para ajustar la potencia y el consumo especfico de combustible. El programa diseado ha considerado la siguiente estructura:1) Proceso de introduccin de datos.- se introducen al programa, todos los datos necesarios para el clculo de la potencia efectiva y rendimiento: Condiciones de referencia y condiciones de potencia efectiva. Datos del combustible: Poder calorfico inferior y densidad relativa. Mediciones de ensayo: potencia en bornes, temperatura, humedad relativa y presin ambiente y consumo de combustible.2) Proceso de validacin de datos de ensayo.- consisti en eliminar todas las mediciones de potencia que superan 2C de la temperatura ambiente[footnoteRef:7] y/o 3% de la potencia promedio. [7: Acorde con el Procedimiento PR-17 del COES (Condiciones particulares de estabilidad para un grupo)]
3) Clculo de la potencia efectiva, la cual ha sido efectuada segn se explica a continuacin: a) Primeramente se lleva todos los datos vlidos de la potencia de ensayo (POTy) a las condiciones de potencia de referencia ISO (POTr) aplicando las curvas de correccin por parmetros de temperatura, humedad, presin, etc. que indica el fabricante.b) Luego se lleva todos los datos de potencia calculados a las condiciones de referencia (POTr) a las condiciones de potencia efectiva (POTx), aplicando igualmente las curvas de correccin por parmetros de temperatura, humedad, presin, etc. que indica el fabricante.c) Esta Norma ser usada referencialmente, ya que las unidades Wartsila 01 y 03 tienen la caracterstica de realizar un ajuste interno a condiciones de sitio de tal manera que la potencia registrada es la potencia corregida en condiciones de sitio. Es as que la potencia efectiva de stas unidades se obtendr como el promedio aritmtico de los valores registrados.
4) Clculo del rendimiento, la cual ha sido efectuada segn se explica a continuacin: a) Definicin del parmetro bsico: Para las unidades Wartsila 01 y 03 se ha considerado el consumo especfico de combustible, de acuerdo a la norma ISO 3046-1:2002. Debido a que las correcciones se realizan de manera interna, el consumo de combustible tambin ha sido precalculado antes de la combustin as de esa manera el consumo en condiciones efectivas ser idntico a los datos registrados. b) Clculo del consumo especfico, rendimiento, Heat Rate (consumo especfico de calor) y eficiencia. En primer lugar, con los datos de energa producida en kWh y el consumo de combustible de ensayo, expresados en m3/h, se determina el consumo especfico de combustible (m3/kWh) a las condiciones de ensayo, estos resultados a las condiciones de referencia y luego a las condiciones de potencia efectiva que resultan ser idnticos. Finalmente considerando el Poder Calorfico Inferior del combustible utilizado, se ha determinado el Heat Rate o consumo especfico de calor (BTU/kWh) y la eficiencia en %.Notas:1. De acuerdo a la definicin estipulada en el procedimiento, existe una presin ambiente de potencia efectiva, que corresponde a la altura al cual se encuentra ubicada la central. Si bien fsicamente la altura no vara durante las pruebas, sin embargo existe una variacin de presin durante las pruebas, por ello es necesario corregir la potencia de ensayo que corresponde con la presin de ensayo y llevarlo a dicha condicin de presin ambiente de potencia efectiva (98.59 kPa). Este valor ha sido determinado en base a la altura (230 msnm) al que se encuentra instalada la Central Trmica de INDEPENDENCIA, que se ha obtenido por dos fuentes: medicin con GPS y del Google Earth.
13. DATOS REGISTRADOS10.1. DATOS REGISTRADOS A PLENA CARGA Los datos registrados en el ensayo para potencia efectiva (100% carga) son como muestra en el CUADRO 101 y CUADRO 102 para las unidades wartsila 01 y 03 respectivamente.CUADRO 101: DATOS DE ENSAYO DE LA UNIDAD WARTSILA 01 (POTENCIA EFECTIVA)NDatos de Ensayo
HoraPotencia de EnsayoConsumo auxiliarTemperatura AmbientePresin BaromtricaConsumo Combustible
Medicin
P y (MW)P aux (KW)Tay (C)Pa y (mbar)mc y (Sm3/h)
01:30:00
101:40:005.715308.33115.838978.6501302.748
201:50:005.715307.52415.670978.5201292.024
302:00:005.716304.74015.460978.4201300.792
402:10:005.715305.52815.280978.3501310.943
502:20:005.715307.12415.120978.3001314.519
602:30:005.716305.14615.100978.3001322.721
702:40:005.716305.18215.110978.3401328.199
802:50:005.715306.17215.100978.3901336.261
903:00:005.715307.86614.920978.3501335.902
1003:10:005.715306.42714.880978.3801324.693
1103:20:005.717308.71914.830978.4801348.827
1203:30:005.716306.79414.900978.5901351.873
1303:40:005.715306.86414.830978.6001355.918
1403:50:005.715305.56414.800978.6001348.654
1504:00:005.715308.86914.800978.6501367.532
1604:10:005.715308.03214.730978.7501362.859
1704:20:005.715306.19714.700978.8601350.448
1804:30:005.715306.53214.700978.9401317.223
1904:40:005.715307.87914.620979.0001324.801
2004:50:005.715306.87214.600979.0601322.273
2105:00:005.715309.05314.540979.1001310.145
2205:10:005.715309.13514.400979.1901295.940
2305:20:005.716307.47414.400979.3301282.901
2405:30:005.715303.81814.400979.5101293.821
2505:40:005.715306.44714.400979.7101300.884
2605:50:005.714307.18614.520979.8501316.259
2706:00:005.715306.20314.550980.0401312.606
2806:10:005.715304.83414.510980.1901296.404
2906:20:005.716306.19914.400980.2901289.182
3006:30:005.691304.16014.400980.3301304.335
Mnimo5.691303.81814.400978.3001282.901
Mximo5.717309.13515.838980.3301367.532
Promedio5.714306.69614.817978.9691320.723
CUADRO 102: DATOS DE ENSAYO DE LA UNIDAD WARTSILA 03 (POTENCIA EFECTIVA)NDatos de Ensayo
HoraPotencia de EnsayoConsumo auxiliarTemperatura AmbientePresin BaromtricaConsumo Combustible
Medicin
P y (MW)P aux (KW)ta y (C)pa y (mbar)mc y (Sm3/h)
101:25:005.717305.18214.080980.3401258.932
201:35:005.717306.17213.910980.3801275.141
301:45:005.716307.86614.090980.3901294.489
401:55:005.716306.42714.180980.4001307.779
502:05:005.717308.71914.110980.3001323.909
602:15:005.716308.71914.100980.2901326.877
702:25:005.717308.71914.100980.2801337.210
802:35:005.716308.33114.150980.3401353.248
902:45:005.716307.52414.120980.2601345.483
1002:55:005.715304.74014.110980.1601370.430
1103:05:005.717305.52814.230980.0901392.601
1203:15:005.715307.12414.300980.1401390.338
1303:25:005.717306.86414.300980.1501394.200
1403:35:005.716305.56414.300980.3301382.565
1503:45:005.717308.86914.300980.2701392.247
1603:55:005.718308.03214.300980.1601380.292
1704:05:005.715306.19714.320980.2401361.003
1804:15:005.719306.53214.400980.2301376.342
1904:25:005.716307.87914.240980.2101375.618
2004:35:005.718306.87214.000980.3201386.646
2104:45:005.717309.05313.810980.3301369.884
2204:55:005.716309.13513.730980.3501371.565
2305:05:005.716307.47413.720980.5001362.523
2405:15:005.715303.81813.820980.5301359.827
2505:25:005.717306.44713.900980.5601366.007
2605:35:005.716307.18613.970980.5401361.261
2705:45:005.716306.20314.070980.6001365.715
2805:55:005.717304.83414.050980.6401366.323
2906:05:005.717306.19913.910980.8101378.535
3006:15:005.702304.16013.900980.9001370.093
Mnimo5.702303.81813.720980.0901258.932
Mximo5.719309.13514.400980.9001394.200
Promedio5.716306.87914.084980.3681356.569
10.2. DATOS REGISTRADOS PARA CARGAS PARCIALESLos datos registrados en el ensayo para cargas parciales (Rendimiento) son como se muestran desde el CUADRO 103 hasta el CUADRO 106 para la unidad Wartsila 01 y desde el CUADRO 107 hasta el CUADRO 1010 para la unidad Wartsila 03.CUADRO 103: DATOS DE ENSAYO PARA 4.0 MW (WARTSILA 01) NDatos de Ensayo
HoraPotencia de EnsayoConsumo auxiliarTemperatura AmbientePresin BaromtricaConsumo Combustible
Medicin
P y (MW)P aux (KW)ta y (C)pa y (mbar)mc y (Sm3/h)
06:45:00
106:46:003.981303.81314.600980.6001032.972
206:47:003.978299.35114.600980.6001031.411
306:48:003.980300.12314.600980.6001033.764
406:49:003.985300.11814.600980.6001042.482
506:50:003.983300.11814.600980.6001032.987
606:51:003.979300.63714.500980.6001027.520
706:52:003.978299.99814.500980.6001028.064
806:53:003.986299.67114.500980.6001020.189
906:54:003.984301.17914.500980.6001021.225
1006:55:003.973300.25214.500980.7001038.071
1106:56:003.980307.82114.500980.6001049.228
1206:57:003.982303.74714.500980.7001049.194
1306:58:003.981300.51314.500980.7001033.840
1406:59:003.977301.35514.600980.7001037.773
1507:00:003.978306.07814.600980.7001040.451
1607:01:003.986303.97114.600980.7001039.363
1707:02:003.983300.23414.600980.7001041.721
1807:03:003.981299.98614.600980.7001040.435
1907:04:003.981302.69014.600980.8001032.930
2007:05:003.983301.10914.500980.8001032.926
2107:06:003.983300.31114.500980.9001037.774
2207:07:003.977300.18114.500980.9001039.539
2307:08:003.988302.28814.500980.9001035.134
2407:09:003.981310.33914.400981.0001044.393
2507:10:003.984299.78714.400980.9001032.241
2607:11:003.984300.74914.400981.0001033.220
2707:12:003.975299.42714.400981.0001035.115
2807:13:003.979299.41114.400981.0001029.402
2907:14:003.984298.94614.400981.0001035.293
3007:15:00
Mnimo3.973298.94614.40980.601020.189
Mximo3.988310.33914.60981.001049.228
Promedio3.981301.52414.52980.751035.471
CUADRO 104 : DATOS DE ENSAYO PARA 3.0 MW (WARTSILA 01)NDatos de Ensayo
HoraPotencia de EnsayoConsumo auxiliarTemperatura AmbientePresin BaromtricaConsumo Combustible
Medicin
P y (MW)P aux (KW)ta y (C)pa y (mbar)mc y (Sm3/h)
07:30:00
107:31:002.980298.36014.500981.100791.119
207:32:002.971302.62014.500981.100789.762
307:33:002.976302.29214.500981.100784.443
407:34:002.979298.83614.500981.100792.950
507:35:002.979307.76614.500981.100799.182
607:36:002.974306.56114.500981.100799.588
707:37:002.971302.76914.500981.200801.092
807:38:002.979302.37414.500981.200801.113
907:39:002.978299.62814.500981.200803.160
1007:40:002.975299.27414.500981.200811.758
1107:41:002.969298.34314.500981.200802.828
1207:42:002.977298.83714.500981.200805.596
1307:43:002.976298.98114.500981.200806.352
1407:44:002.979304.40614.500981.200804.022
1507:45:002.968305.79314.500981.300808.572
1607:46:002.978298.55614.600981.200809.238
1707:47:002.978298.71614.600981.300812.205
1807:48:002.977298.46414.600981.300808.822
1907:49:002.970305.20914.500981.300809.891
2007:50:002.975304.08414.500981.200806.516
2107:51:002.976300.81714.400981.300809.366
2207:52:002.977299.20214.400981.300800.383
2307:53:002.974300.31914.500981.300799.974
2407:54:002.976299.10114.500981.300794.031
2507:55:002.968297.63414.500981.300803.669
2607:56:002.982303.33814.500981.400803.805
2707:57:002.973302.02714.500981.400802.408
2807:58:002.971298.19714.500981.400811.735
2907:59:002.973298.98714.600981.400805.382
3008:00:002.980299.77714.600981.400806.343
Mnimo2.968297.63414.40981.10784.443
Mximo2.982307.76614.60981.40812.205
Promedio2.975301.04214.51981.24802.843
CUADRO 105 : DATOS DE ENSAYO PARA 2.0 MW (WARTSILA 01)NDatos de Ensayo
HoraPotencia de EnsayoConsumo auxiliarTemperatura AmbientePresin BaromtricaConsumo Combustible
Medicin
P y (MW)Paux (KW)Tay (C)Pa y (mbar)mc y (Sm3/h)
108:16:002.007302.70215.30980.70555.828
208:17:002.000304.04215.30980.70556.475
308:18:002.005305.93815.30980.70553.747
408:19:002.001309.84615.30980.70561.202
508:20:002.004301.94615.30980.70556.970
608:21:002.003300.31515.30980.70552.085
708:22:001.999301.23115.30980.80549.726
808:23:002.003303.13515.30980.80543.346
908:24:002.003301.94415.30980.80547.317
1008:25:002.006308.60715.40980.80542.245
1108:26:001.998301.01215.40980.80543.699
1208:27:002.006301.41215.40980.80543.709
1308:28:002.000300.43115.40980.80545.952
1408:29:002.005301.62415.40980.80543.775
1508:30:002.002300.98815.40980.90543.615
1608:31:002.002309.43015.40980.90542.339
1708:32:002.003302.86015.40980.90538.620
1808:33:002.005302.26815.40980.90540.427
1908:34:002.007300.88515.40980.90538.675
2008:35:001.996301.20315.40980.90533.917
2108:36:001.998303.38915.40980.90534.690
2208:37:002.004311.52815.40980.90530.543
2308:38:002.002304.12515.40980.90529.794
2408:39:002.002303.93315.40980.90522.961
2508:40:002.004303.38515.40980.90525.529
2608:41:002.005301.98115.50981.00528.604
2708:42:002.005303.24515.50981.00526.710
2808:43:002.003312.30115.50981.00528.029
2908:44:001.998301.43315.50981.00524.279
3008:45:002.004301.87015.60981.00527.070
Mnimo1.996300.31515.30980.70522.961
Mximo2.007312.30115.60981.00561.202
Promedio2.003303.63415.39980.85540.396
CUADRO 106 : DATOS DE ENSAYO PARA 1.5 MW (WARTSILA 01)NDatos de Ensayo
HoraPotencia de EnsayoConsumo auxiliarTemperatura AmbientePresin BaromtricaConsumo Combustible
Medicin
P y (MW)P aux (KW)ta y (C)pa y (mbar)mc y (Sm3/h)
09:00:00
109:01:001.488304.55814.800981.600529.678
209:02:001.478299.30914.800981.600530.311
309:03:001.493300.37014.800981.600528.410
409:04:001.484299.36514.900981.600534.894
509:05:001.486298.85514.900981.600530.169
609:06:001.477302.18314.900981.600530.153
709:07:001.489303.86314.900981.600528.788
809:08:001.484299.40815.000981.600525.676
909:09:001.489299.78215.000981.600525.809
1009:10:001.490301.08615.000981.600516.720
1109:11:001.482303.29015.000981.600517.096
1209:12:001.480308.58615.000981.600518.383
1309:13:001.491306.45715.000981.600518.567
1409:14:001.489302.56715.000981.700521.792
1509:15:001.495303.81415.100981.600523.851
1609:16:001.481303.24315.100981.600526.428
1709:17:001.482302.71715.100981.600529.290
1809:18:001.491306.77915.100981.600535.781
1909:19:001.488300.27415.100981.600530.645
2009:20:001.486298.93915.100981.600532.447
2109:21:001.494298.36815.100981.700529.682
2209:22:001.485299.44515.100981.600537.385
2309:23:001.487300.20915.100981.600535.226
2409:24:001.492304.57215.000981.700532.619
2509:25:001.477297.55015.000981.600532.077
2609:26:001.488302.11715.000981.700528.304
2709:27:001.484301.16815.100981.600534.531
2809:28:001.497299.31715.100981.600528.946
2909:29:001.483304.00815.100981.600528.150
3009:30:001.486303.68515.200981.600536.344
Mnimo1.477297.55014.80981.600516.720
Mximo1.497308.58615.20981.700537.385
Promedio1.487301.86315.01981.613528.605
A continuacin los registros obtenidos para cargas parciales de la unidad Wartsila 03CUADRO 107: DATOS DE ENSAYO PARA 4.0 MW (WARTSILA 03)NDatos de Ensayo
HoraPotencia de EnsayoConsumo auxiliarTemperatura AmbientePresin BaromtricaConsumo Combustible
Medicin
P y (MW)P aux (KW)ta y (C)pa y (mbar)mc y (Sm3/h)
106:31:003.980303.81313.800981.0001010.360
206:32:003.981299.35113.800981.0001006.370
306:33:003.976300.12313.800981.0001021.078
406:34:003.995300.11813.800980.9001012.258
506:35:003.984300.11813.800981.0001007.245
606:36:003.981300.63713.800981.0001014.945
706:37:003.980299.99813.800981.0001007.757
806:38:003.993299.67113.800981.1001006.714
906:39:003.985301.17913.800981.1001007.004
1006:40:003.981300.25213.800981.100994.861
1106:41:003.977307.82113.800981.1001001.201
1206:42:003.992303.74713.800981.1001001.097
1306:43:003.987300.51313.800981.100996.433
1406:44:003.988301.35513.800981.200999.274
1506:45:003.972306.07813.800981.100992.607
1606:46:003.990303.97113.800981.100998.237
1706:47:003.988300.23413.800981.2001000.025
1806:48:003.990299.98613.800981.200998.062
1906:49:003.974302.69013.800981.1001001.617
2006:50:003.990301.10913.800981.2001000.281
2106:51:003.991300.31113.800981.200992.445
2206:52:003.992300.18113.800981.200990.064
2306:53:003.978302.28813.800981.300981.081
2406:54:003.991310.33913.800981.300984.223
2506:55:003.990299.78713.800981.300997.648
2606:56:003.987300.74913.800981.300992.113
2706:57:003.972299.42713.800981.400985.251
2806:58:003.984299.41113.800981.400985.505
2906:59:003.991298.94613.800981.500987.891
3007:00:003.985306.36713.800981.500982.266
Mnimo3.972298.94613.80980.90981.081
Mximo3.995310.33913.80981.501021.078
Promedio3.985301.68613.80981.17998.530
CUADRO 108: DATOS DE ENSAYO PARA 3.0 MW (WARTSILA 03)NDatos de Ensayo
HoraPotencia de EnsayoConsumo auxiliarTemperatura AmbientePresin BaromtricaConsumo Combustible
Medicin
P y (MW)P aux (KW)ta y (C)pa y (mbar)mc y (Sm3/h)
107:16:002.985298.36013.800981.800812.023
207:17:002.984302.62013.800981.800810.504
307:18:002.986302.29213.800981.800810.894
407:19:002.982298.83613.700981.800807.119
507:20:002.983307.76613.700981.800804.996
607:21:002.984306.56113.700981.900803.557
707:22:002.980302.76913.700981.900794.438
807:23:002.982302.37413.700981.900782.532
907:24:002.981299.62813.700981.900784.158
1007:25:002.985299.27413.700981.900790.978
1107:26:002.988298.34313.700981.900792.770
1207:27:002.976298.83713.700981.900795.274
1307:28:002.981298.98113.800981.900798.508
1407:29:002.988304.40613.800981.900797.996
1507:30:002.980305.79313.800981.900793.716
1607:31:002.979298.55613.800981.900791.027
1707:32:002.979298.71613.800981.900788.434
1807:33:002.994298.46413.800982.000784.291
1907:34:002.984305.20913.800982.000787.894
2007:35:002.979304.08413.800982.000784.313
2107:36:002.982300.81713.800982.100786.095
2207:37:002.981299.20213.800982.100786.715
2307:38:002.987300.31913.800982.100788.208
2407:39:002.981299.10113.800982.000790.009
2507:40:002.976297.63413.800982.100792.062
2607:41:002.988303.33813.800982.100795.037
2707:42:002.980302.02713.800982.200792.706
2807:43:002.985298.19713.900982.200792.626
2907:44:002.977298.98713.900982.200791.614
3007:45:002.930299.77713.900982.300791.812
Mnimo2.930297.63413.70981.80782.532
Mximo2.994307.76613.90982.30812.023
Promedio2.981301.04213.78981.97794.077
CUADRO 109 : DATOS DE ENSAYO PARA 2.0 MW (WARTSILA 03)NDatos de Ensayo
HoraPotencia de EnsayoConsumo auxiliarTemperatura AmbientePresin BaromtricaConsumo Combustible
Medicin
P y (MW)P aux (KW)ta y (C)pa y (mbar)mc y (Sm3/h)
108:01:001.987299.01614.100982.300619.176
208:02:001.984299.93114.100982.300623.124
308:03:001.993301.83314.100982.400619.589
408:04:001.993300.96714.100982.400624.215
508:05:001.979299.58614.200982.400625.078
608:06:001.984299.90414.200982.400622.892
708:07:001.989302.08714.200982.400624.536
808:08:001.994300.64314.200982.400625.809
908:09:001.989300.32414.300982.400623.369
1008:10:001.984299.68814.300982.400617.149
1108:11:001.991308.12214.300982.500616.018
1208:12:001.987301.55814.300982.500617.116
1308:13:001.991301.94314.400982.500614.068
1408:14:001.985310.99014.400982.500615.577
1508:15:001.993300.13314.400982.500617.255
1608:16:001.988300.57014.400982.500621.718
1708:17:001.991310.21814.500982.500624.145
1808:18:001.983302.82314.500982.500626.734
1908:19:001.992302.63014.500982.500622.862
2008:20:001.988302.08314.500982.600627.317
2108:21:001.995300.68014.500982.500629.750
2208:22:001.988299.71214.500982.500628.964
2308:23:001.990300.11214.500982.600622.070
2408:24:001.998299.13214.500982.600626.818
2508:25:001.990301.40014.500982.600626.897
2608:26:001.984302.74014.600982.600617.461
2708:27:001.987304.63314.600982.600621.149
2808:28:001.984308.53714.600982.600617.619
2908:29:001.987312.44214.600982.700621.648
3008:30:001.987316.34614.700982.700615.823
Mnimo1.979299.01614.10982.30614.068
Mximo1.998316.34614.70982.70629.750
Promedio1.988303.02614.39982.50621.865
CUADRO 1010 : DATOS DE ENSAYO PARA 1.5 MW (WARTSILA 03)NDatos de Ensayo
HoraPotencia de EnsayoConsumo auxiliarTemperatura AmbientePresin BaromtricaConsumo Combustible
Medicin
P y (MW)P aux (KW)ta y (C)pa y (mbar)mc y (Sm3/h)
09:00:00
108:46:001.489304.55814.900982.800538.592
208:47:001.500299.30914.900982.800531.733
308:48:001.479300.37014.900982.800533.290
408:49:001.501299.36515.000982.800528.418
508:50:001.491298.85515.000982.800534.696
608:51:001.492302.18315.000982.800535.173
708:52:001.491303.86315.000982.900535.819
808:53:001.495299.40815.000982.900535.706
908:54:001.489299.78215.100982.900543.962
1008:55:001.495301.08615.100982.900550.390
1108:56:001.489303.29015.100982.900547.260
1208:57:001.489308.58615.100982.900551.860
1308:58:001.489306.45715.100982.900545.092
1408:59:001.496302.56715.100982.800543.373
1509:00:001.485303.81415.100982.900533.132
1609:01:001.483303.24315.200982.900536.212
1709:02:001.495302.71715.200982.900544.363
1809:03:001.493306.77915.200982.800542.675
1909:04:001.489300.27415.200982.800542.817
2009:05:001.490298.93915.200982.800537.760
2109:06:001.495298.36815.200982.800541.678
2209:07:001.497299.44515.200982.800534.604
2309:08:001.492300.20915.200982.800534.758
2409:09:001.493304.57215.300982.800535.722
2509:10:001.495297.55015.300982.800533.257
2609:11:001.496302.11715.200982.900535.502
2709:12:001.492301.16815.300982.900542.109
2809:13:001.489299.31715.300982.900544.333
2909:14:001.496304.00815.300982.900543.103
3009:15:001.495303.68515.300982.900546.908
Mnimo1.479297.55014.90982.800528.418
Mximo1.501308.58615.30982.900551.860
Promedio1.492301.86315.13982.850539.477
11. VALIDACION DE DATOS La validacin de los datos registrados solo es aplicable a mxima carga como se muestra en el CUADRO 111 y CUADRO 112 para las unidades Wartsila 01 y Wartsila 03.CUADRO 111 : VALIDACION DE DATOS (WARTSILA 01)NDatos de Ensayovariabilidad de datos
HoraPotencia de EnsayoConsumo auxiliarTemperatura AmbientePresin BaromtricaConsumo Combustible
Medicinvariables primarias
P y (MW)P aux (KW)ta y (C)pa y (mbar)mc y (Sm3/h)P y (kW)P aux (KW)ta y (C)pa y (mbar)
01:30:00
101:40:005.715308.33115.838978.6501302.748-0.008-0.53-1.0210.033
201:50:005.715307.52415.670978.5201292.024-0.010-0.27-0.8530.046
302:00:005.716304.74015.460978.4201300.792-0.0370.64-0.6430.056
402:10:005.715305.52815.280978.3501310.943-0.0130.38-0.4630.063
502:20:005.715307.12415.120978.3001314.519-0.010-0.14-0.3030.068
602:30:005.716305.14615.100978.3001322.721-0.0210.51-0.2830.068
702:40:005.716305.18215.110978.3401328.199-0.0260.49-0.2930.064
802:50:005.715306.17215.100978.3901336.261-0.0190.17-0.2830.059
903:00:005.715307.86614.920978.3501335.902-0.003-0.38-0.1030.063
1003:10:005.715306.42714.880978.3801324.693-0.0120.09-0.0630.060
1103:20:005.717308.71914.830978.4801348.827-0.040-0.66-0.0130.050
1203:30:005.716306.79414.900978.5901351.873-0.024-0.03-0.0830.039
1303:40:005.715306.86414.830978.6001355.918-0.013-0.05-0.0130.038
1403:50:005.715305.56414.800978.6001348.654-0.0140.370.0170.038
1504:00:005.715308.86914.800978.6501367.532-0.014-0.710.0170.033
1604:10:005.715308.03214.730978.7501362.859-0.005-0.440.0870.022
1704:20:005.715306.19714.700978.8601350.448-0.0070.160.1170.011
1804:30:005.715306.53214.700978.9401317.223-0.0140.050.1170.003
1904:40:005.715307.87914.620979.0001324.801-0.012-0.390.197-0.003
2004:50:005.715306.87214.600979.0601322.273-0.012-0.060.217-0.009
2105:00:005.715309.05314.540979.1001310.145-0.004-0.770.277-0.013
2205:10:005.715309.13514.400979.1901295.940-0.012-0.800.417-0.023
2305:20:005.716307.47414.400979.3301282.901-0.024-0.250.417-0.037
2405:30:005.715303.81814.400979.5101293.821-0.0060.940.417-0.055
2505:40:005.715306.44714.400979.7101300.884-0.0030.080.417-0.076
2605:50:005.714307.18614.520979.8501316.2590.013-0.160.297-0.090
2706:00:005.715306.20314.550980.0401312.606-0.0100.160.267-0.109
2806:10:005.715304.83414.510980.1901296.404-0.0190.610.307-0.125
2906:20:005.716306.19914.400980.2901289.182-0.0270.160.417-0.135
3006:30:005.691304.16014.400980.3301304.3350.4060.830.417-0.139
Mnimo5.691303.81814.400978.3001282.901
Mximo5.717309.13515.838980.3301367.5323%3%2K0.5
Promedio5.714306.69614.817978.9691320.723
CUADRO 112: VALIDACION DE DATOS (WARTSILA 03)NDatos de Ensayovariabilidad de datos
HoraPotencia de EnsayoConsumo auxiliarTemperatura AmbientePresin BarometricaConsumo Combustible
Medicinvariables primarias
P y (MW)P aux (KW)ta y (C)pa y (mbar)mc y (Sm3/h)P y (kW)P aux (KW)ta y (C)pa y (mbar)
101:25:005.717305.18214.080980.3401258.932-0.0120.550.0040.003
201:35:005.717306.17213.910980.3801275.141-0.0170.230.174-0.001
301:45:005.716307.86614.090980.3901294.4890.001-0.32-0.006-0.002
401:55:005.716306.42714.180980.4001307.779-0.0030.15-0.096-0.003
502:05:005.717308.71914.110980.3001323.909-0.014-0.60-0.0260.007
602:15:005.716308.71914.100980.2901326.8770.004-0.60-0.0160.008
702:25:005.717308.71914.100980.2801337.210-0.015-0.60-0.0160.009
802:35:005.716308.33114.150980.3401353.248-0.001-0.47-0.0660.003
902:45:005.716307.52414.120980.2601345.483-0.006-0.21-0.0360.011
1002:55:005.715304.74014.110980.1601370.4300.0190.70-0.0260.021
1103:05:005.717305.52814.230980.0901392.601-0.0140.44-0.1460.028
1203:15:005.715307.12414.300980.1401390.3380.019-0.08-0.2160.023
1303:25:005.717306.86414.300980.1501394.200-0.0120.00-0.2160.022
1403:35:005.716305.56414.300980.3301382.565-0.0050.43-0.2160.004
1503:45:005.717308.86914.300980.2701392.247-0.011-0.65-0.2160.010
1603:55:005.718308.03214.300980.1601380.292-0.028-0.38-0.2160.021
1704:05:005.715306.19714.320980.2401361.0030.0140.22-0.2360.013
1804:15:005.719306.53214.400980.2301376.342-0.0520.11-0.3160.014
1904:25:005.716307.87914.240980.2101375.618-0.004-0.33-0.1560.016
2004:35:005.718306.87214.000980.3201386.646-0.0350.000.0840.005
2104:45:005.717309.05313.810980.3301369.884-0.017-0.710.2740.004
2204:55:005.716309.13513.730980.3501371.565-0.009-0.740.3540.002
2305:05:005.716307.47413.720980.5001362.523-0.009-0.190.364-0.013
2405:15:005.715303.81813.820980.5301359.8270.0201.000.264-0.017
2505:25:005.717306.44713.900980.5601366.007-0.0190.140.184-0.020
2605:35:005.716307.18613.970980.5401361.2610.003-0.100.114-0.018
2705:45:005.716306.20314.070980.6001365.715-0.0060.220.014-0.024
2805:55:005.717304.83414.050980.6401366.323-0.0210.670.034-0.028
2906:05:005.717306.19913.910980.8101378.535-0.0160.220.174-0.045
3006:15:005.702304.16013.900980.9001370.0930.2490.890.184-0.054
Mnimo5.702303.81813.720980.0901258.932
Mximo5.719309.13514.400980.9001394.2003%3%2K0.5
Promedio5.716306.87914.084980.3681356.569
En el CUADRO 111 y CUADRO 112, se observa que todos los datos registrados estn dentro del rango de variabilidad de parmetros de estabilidad de la unidad Wartsila 01 Wartsila 03; por lo tanto se validan los datos registrados para estas unidades a plena carga. Cabe mencionar que dentro de las cargas parciales se elimina el registro correspondiente a las 07:15:00 horas por exceder la variacin de potencia.12. DATOS VALIDADOSLuego de realizar la validacin en el captulo anterior, se muestra en el CUADRO 121, los valores filtrados y los cuales se utiliza para la determinacin de la potencia efectiva y rendimiento.CUADRO 121: DATOS VALIDADOS DE LA UNIDAD WARTSILA 01 (POTENCIA EFECTIVA)NDatos de Ensayo
HoraPotencia de EnsayoConsumo auxiliarTemperatura AmbientePresin BaromtricaConsumo Combustible
Medicin
P y (MW)P aux (KW)ta y (C)pa y (mbar)mc y (Sm3/h)
01:30:00
101:40:005.715308.33115.838978.6501302.748
201:50:005.715307.52415.670978.5201292.024
302:00:005.716304.74015.460978.4201300.792
402:10:005.715305.52815.280978.3501310.943
502:20:005.715307.12415.120978.3001314.519
602:30:005.716305.14615.100978.3001322.721
702:40:005.716305.18215.110978.3401328.199
802:50:005.715306.17215.100978.3901336.261
903:00:005.715307.86614.920978.3501335.902
1003:10:005.715306.42714.880978.3801324.693
1103:20:005.717308.71914.830978.4801348.827
1203:30:005.716306.79414.900978.5901351.873
1303:40:005.715306.86414.830978.6001355.918
1403:50:005.715305.56414.800978.6001348.654
1504:00:005.715308.86914.800978.6501367.532
1604:10:005.715308.03214.730978.7501362.859
1704:20:005.715306.19714.700978.8601350.448
1804:30:005.715306.53214.700978.9401317.223
1904:40:005.715307.87914.620979.0001324.801
2004:50:005.715306.87214.600979.0601322.273
2105:00:005.715309.05314.540979.1001310.145
2205:10:005.715309.13514.400979.1901295.940
2305:20:005.716307.47414.400979.3301282.901
2405:30:005.715303.81814.400979.5101293.821
2505:40:005.715306.44714.400979.7101300.884
2605:50:005.714307.18614.520979.8501316.259
2706:00:005.715306.20314.550980.0401312.606
2806:10:005.715304.83414.510980.1901296.404
2906:20:005.716306.19914.400980.2901289.182
3006:30:005.691304.16014.400980.3301304.335
Mnimo5.691303.81814.400978.3001282.901
Mximo5.717309.13515.838980.3301367.532
Promedio5.714306.69614.817978.9691320.723
CUADRO 122: DATOS VALIDADOS DE LA UNIDAD WARTSILA 03 (POTENCIA EFECTIVA)NDatos de Ensayo
HoraPotencia de EnsayoConsumo auxiliarTemperatura AmbientePresin BaromtricaConsumo Combustible
Medicin
P y (MW)P aux (KW)ta y (C)pa y (mbar)mc y (Sm3/h)
101:25:005.717305.18214.080980.3401258.932
201:35:005.717306.17213.910980.3801275.141
301:45:005.716307.86614.090980.3901294.489
401:55:005.716306.42714.180980.4001307.779
502:05:005.717308.71914.110980.3001323.909
602:15:005.716308.71914.100980.2901326.877
702:25:005.717308.71914.100980.2801337.210
802:35:005.716308.33114.150980.3401353.248
902:45:005.716307.52414.120980.2601345.483
1002:55:005.715304.74014.110980.1601370.430
1103:05:005.717305.52814.230980.0901392.601
1203:15:005.715307.12414.300980.1401390.338
1303:25:005.717306.86414.300980.1501394.200
1403:35:005.716305.56414.300980.3301382.565
1503:45:005.717308.86914.300980.2701392.247
1603:55:005.718308.03214.300980.1601380.292
1704:05:005.715306.19714.320980.2401361.003
1804:15:005.719306.53214.400980.2301376.342
1904:25:005.716307.87914.240980.2101375.618
2004:35:005.718306.87214.000980.3201386.646
2104:45:005.717309.05313.810980.3301369.884
2204:55:005.716309.13513.730980.3501371.565
2305:05:005.716307.47413.720980.5001362.523
2405:15:005.715303.81813.820980.5301359.827
2505:25:005.717306.44713.900980.5601366.007
2605:35:005.716307.18613.970980.5401361.261
2705:45:005.716306.20314.070980.6001365.715
2805:55:005.717304.83414.050980.6401366.323
2906:05:005.717306.19913.910980.8101378.535
3006:15:005.702304.16013.900980.9001370.093
Mnimo5.702303.81813.720980.0901258.932
Mximo5.719309.13514.400980.9001394.200
Promedio5.716306.87914.084980.3681356.569
13. CALCULOS Y RESULTADOSSe realiz el clculo de la potencia efectiva y rendimiento como se muestra en el CUADRO 131 y CUADRO 133.13.1. POTENCIA EFECTIVACUADRO 131: CLCULO DE LA POTECIA EFECTIVA (Wartsila 01)NPotencia Efectiva
HoraPotencia de EnsayoPotencia ISOPotencia Efectiva
Medicin
P y (MW)P ISO (MW)P x (MW)
01:30:00
101:40:005.714805.714805.71480
201:50:005.714915.714915.71491
302:00:005.716445.716445.71644
402:10:005.715105.715105.71510
502:20:005.714915.714915.71491
602:30:005.715575.715575.71557
702:40:005.715835.715835.71583
802:50:005.715445.715445.71544
903:00:005.714515.714515.71451
1003:10:005.715055.715055.71505
1103:20:005.716655.716655.71665
1203:30:005.715745.715745.71574
1303:40:005.715075.715075.71507
1403:50:005.715135.715135.71513
1504:00:005.715175.715175.71517
1604:10:005.714665.714665.71466
1704:20:005.714755.714755.71475
1804:30:005.715175.715175.71517
1904:40:005.715015.715015.71501
2004:50:005.715015.715015.71501
2105:00:005.714575.714575.71457
2205:10:005.715045.715045.71504
2305:20:005.715745.715745.71574
2405:30:005.714705.714705.71470
2505:40:005.714515.714515.71451
2605:50:005.713625.713625.71362
2706:00:005.714935.714935.71493
2806:10:005.715445.715445.71544
2906:20:005.715875.715875.71587
3006:30:005.691135.691135.69113
Mnimo5.691135.691135.69113
Mximo5.716655.716655.71665
Promedio5.714355.714355.71435
CUADRO 132: POTENCIAS DE ENSAYO, ISO Y EFECTTIVA (Wartsila 01)UnidadPOTENCIA DE ENSAYO POTy (KW)POTENCIA DE REFERENCIA POTr (KW)POTENCIA DE SITIO POTx (KW)POTENCIA DE SSAA (KW)
Wartsila 015 714.355 714.355 714.35306.696
CUADRO 133: CLCULO DE LA POTECIA EFECTIVA (Wartsila 03)NPotencia Efectiva
HoraPotencia de EnsayoPotencia ISOPotencia Efectiva
Medicin
P y (MW)P ISO (MW)P x (MW)
101:25:005.716635.716635.71663
201:35:005.716905.716905.71690
301:45:005.715875.715875.71587
401:55:005.716105.716105.71610
502:05:005.716745.716745.71674
602:15:005.715715.715715.71571
702:25:005.716795.716795.71679
802:35:005.715985.715985.71598
902:45:005.716295.716295.71629
1002:55:005.714825.714825.71482
1103:05:005.716735.716735.71673
1203:15:005.714815.714815.71481
1303:25:005.716605.716605.71660
1403:35:005.716235.716235.71623
1503:45:005.716555.716555.71655
1603:55:005.717545.717545.71754
1704:05:005.715115.715115.71511
1804:15:005.718905.718905.71890
1904:25:005.716155.716155.71615
2004:35:005.717955.717955.71795
2104:45:005.716885.716885.71688
2204:55:005.716425.716425.71642
2305:05:005.716445.716445.71644
2405:15:005.714805.714805.71480
2505:25:005.716985.716985.71698
2605:35:005.715725.715725.71572
2705:45:005.716245.716245.71624
2805:55:005.717145.717145.71714
2906:05:005.716865.716865.71686
3006:15:005.701705.701705.70170
Mnimo5.701705.701705.70170
Mximo5.718905.718905.71890
Promedio5.715925.715925.71592
CUADRO 134: POTENCIAS DE ENSAYO, ISO Y EFECTTIVA (Wartsila 03)UnidadPOTENCIA DE ENSAYO POTy (KW)POTENCIA DE REFERENCIA POTr (KW)POTENCIA DE SITIO POTx (KW)POTENCIA DE SSAA (KW)
Wartsila 035 715.925 715.925 715.92306.879
13.2. RENDIMIENTO Y OTROS NDICES RELACIONADOS AL CONSUMO DE COMBUSTIBLEA condiciones de ensayo se obtienen los siguientes resultados de consumo[footnoteRef:8]. (Ver [8: Se ha tomado los valores de Poder calorfico Inferior o Neto y Densidad del CUADRO 81.]
CUADRO 135 y CUADRO 136).CUADRO 135: RESULTADOS DE RENDIMIENTO, CONSUMO, EFICIENCIA A CONDICIONES DE ENSAYO (Wartsila 01)NDatos de Ensayondices a Condiciones de Ensayo
Potencia de Ensayo P yConsumo combustible mc yRendimiento R yConsumo Especfico de Calor Cec yEficiencia y
Medicin(MW)(m3/h)(kWh/m3)(kJ/kWh)(%)
15,7151302,7484,3878245,7843,66
25,7151292,0244,4238177,7544,02
35,7161300,7924,3958231,0543,74
45,7151310,9434,3608297,2243,39
55,7151314,5194,3488320,1243,27
65,7161322,7214,3218371,0843,01
75,7161328,1994,3038405,3642,83
85,7151336,2614,2778456,9642,57
95,7151335,9024,2788456,0642,57
105,7151324,6934,3148384,3142,94
115,7171348,8274,2388534,6842,18
125,7161351,8734,2288555,3142,08
135,7151355,9184,2158581,9241,95
145,7151348,6544,2388535,8642,18
155,7151367,5324,1798655,2841,59
165,7151362,8594,1938626,4741,73
175,7151350,4484,2328547,7842,12
185,7151317,2234,3398336,8643,18
195,7151324,8014,3148385,0742,93
205,7151322,2734,3228369,0643,02
215,7151310,1454,3628292,9343,41
225,7151295,9404,4108202,3543,89
235,7161282,9014,4558118,8344,34
245,7151293,8214,4178189,4343,96
255,7151300,8844,3938234,4043,72
265,7141316,2594,3418333,0243,20
275,7151312,6064,3548308,0043,33
285,7151296,4044,4098204,7143,88
295,7161289,1824,4348158,3844,13
305,6911304,3354,3638290,1743,42
Mnimo5,6911282,9014,1798118,8341,593
Mximo5,7171367,5324,4558655,2844,341
Promedio5,7141320,7234,3288360,2143,074
CUADRO 136: RESULTADOS DE RENDIMIENTO, CONSUMO, EFICIENCIAA CONDICIONES DE ENSAYO (Wartsila 03)NDatos de Ensayondices a Condiciones de Ensayo
Potencia de Ensayo P yConsumo combustible mc yRendimiento R yConsumo Especfico de Calor Cec yEficiencia y
Medicin(MW)(m3/h)(kWh/m3)(kJ/kWh)(%)
15,7171258,9324,5417965,0245,20
25,7171275,1414,4838067,1844,63
35,7161294,4894,4168191,0743,95
45,7161307,7794,3718274,8343,51
55,7171323,9094,3188375,9542,98
65,7161326,8774,3088396,2442,88
75,7171337,2104,2758460,0442,55
85,7161353,2484,2248562,7242,04
95,7161345,4834,2498513,1142,29
105,7151370,4304,1708673,1941,51
115,7171392,6014,1058810,5640,86
125,7151390,3384,1108799,2040,91
135,7171394,2004,1008820,8740,81
145,7161382,5654,1358747,8441,15
155,7171392,2474,1068808,6040,87
165,7181380,2924,1428731,4541,23
175,7151361,0034,1998613,0941,80
185,7191376,3424,1558704,4041,36
195,7161375,6184,1558704,0041,36
205,7181386,6464,1248771,0241,04
215,7171369,8844,1738666,6141,54
225,7161371,5654,1688677,9541,48
235,7161362,5234,1958620,7141,76
245,7151359,8274,2038606,1241,83
255,7171366,0074,1858641,9341,66
265,7161361,2614,1998613,8141,79
275,7161365,7154,1868641,2041,66
285,7171366,3234,1848643,6841,65
295,7171378,5354,1478721,3741,28
305,7021370,0934,1628691,0241,42
Mnimo5,7021258,9324,1007965,0240,812
Mximo5,7191394,2004,5418820,8745,198
Promedio5,7161356,5694,2168583,8341,967
InformeGeneradorEmpresa ConsultoraVeedorPgina N
VersinFinalEGESURHAMEKCOES8
CUADRO 137: RESULTADOS DE LOS NDICES DE CONSUMO (Wartsila 01)NDatos de Ensayondices a Condiciones de Ensayondices a Condiciones Efectivas
Potencia de Ensayo P yConsumo combustible mc yRendimiento R yConsumo Especfico de Calor Cec yEficiencia yRendimiento R xConsumo Especfico de Calor Cec xConsumo combustible mc xEficiencia x
Medicin(MW)(m3/h)(kWh/m3)(kJ/kWh)(%)(kWh/m3)(kJ/kWh)(m3/h)(%)
15,7151302,7484,3878245,7843,664,3878245,781302,74843,66
25,7151292,0244,4238177,7544,024,4238177,751292,02444,02
35,7161300,7924,3958231,0543,744,3958231,051300,79243,74
45,7151310,9434,3608297,2243,394,3608297,221310,94343,39
55,7151314,5194,3488320,1243,274,3488320,121314,51943,27
65,7161322,7214,3218371,0843,014,3218371,081322,72143,01
75,7161328,1994,3038405,3642,834,3038405,361328,19942,83
85,7151336,2614,2778456,9642,574,2778456,961336,26142,57
95,7151335,9024,2788456,0642,574,2788456,061335,90242,57
105,7151324,6934,3148384,3142,944,3148384,311324,69342,94
115,7171348,8274,2388534,6842,184,2388534,681348,82742,18
125,7161351,8734,2288555,3142,084,2288555,311351,87342,08
135,7151355,9184,2158581,9241,954,2158581,921355,91841,95
145,7151348,6544,2388535,8642,184,2388535,861348,65442,18
155,7151367,5324,1798655,2841,594,1798655,281367,53241,59
165,7151362,8594,1938626,4741,734,1938626,471362,85941,73
175,7151350,4484,2328547,7842,124,2328547,781350,44842,12
185,7151317,2234,3398336,8643,184,3398336,861317,22343,18
195,7151324,8014,3148385,0742,934,3148385,071324,80142,93
205,7151322,2734,3228369,0643,024,3228369,061322,27343,02
215,7151310,1454,3628292,9343,414,3628292,931310,14543,41
225,7151295,9404,4108202,3543,894,4108202,351295,94043,89
235,7161282,9014,4558118,8344,344,4558118,831282,90144,34
245,7151293,8214,4178189,4343,964,4178189,431293,82143,96
255,7151300,8844,3938234,4043,724,3938234,401300,88443,72
265,7141316,2594,3418333,0243,204,3418333,021316,25943,20
275,7151312,6064,3548308,0043,334,3548308,001312,60643,33
285,7151296,4044,4098204,7143,884,4098204,711296,40443,88
295,7161289,1824,4348158,3844,134,4348158,381289,18244,13
305,6911304,3354,3638290,1743,424,3638290,171304,33543,42
Mnimo5,6911282,9014,1798118,8341,5934,1798118,831282,9041,593
Mximo5,7171367,5324,4558655,2844,3414,4558655,281367,5344,341
Promedio5,7141320,7234,3288360,2143,0744,3288360,211320,7243,074
CUADRO 138: RESULTADOS DE LOS NDICES DE CONSUMO (Wartsila 03)NDatos de Ensayondices a Condiciones de Ensayondices a Condiciones Efectivas
Potencia de Ensayo P yConsumo combustible mc yRendimiento R yConsumo Especfico de Calor Cec yEficiencia yRendimiento R xConsumo Especfico de Calor Cec xConsumo combustible mc xEficiencia x
Medicin(MW)(m3/h)(kWh/m3)(kJ/kWh)(%)(kWh/m3)(kJ/kWh)(m3/h)(%)
15,7171258,9324,5417965,0245,204,5417965,021258,93245,20
25,7171275,1414,4838067,1844,634,4838067,181275,14144,63
35,7161294,4894,4168191,0743,954,4168191,071294,48943,95
45,7161307,7794,3718274,8343,514,3718274,831307,77943,51
55,7171323,9094,3188375,9542,984,3188375,951323,90942,98
65,7161326,8774,3088396,2442,884,3088396,241326,87742,88
75,7171337,2104,2758460,0442,554,2758460,041337,21042,55
85,7161353,2484,2248562,7242,044,2248562,721353,24842,04
95,7161345,4834,2498513,1142,294,2498513,111345,48342,29
105,7151370,4304,1708673,1941,514,1708673,191370,43041,51
115,7171392,6014,1058810,5640,864,1058810,561392,60140,86
125,7151390,3384,1108799,2040,914,1108799,201390,33840,91
135,7171394,2004,1008820,8740,814,1008820,871394,20040,81
145,7161382,5654,1358747,8441,154,1358747,841382,56541,15
155,7171392,2474,1068808,6040,874,1068808,601392,24740,87
165,7181380,2924,1428731,4541,234,1428731,451380,29241,23
175,7151361,0034,1998613,0941,804,1998613,091361,00341,80
185,7191376,3424,1558704,4041,364,1558704,401376,34241,36
195,7161375,6184,1558704,0041,364,1558704,001375,61841,36
205,7181386,6464,1248771,0241,044,1248771,021386,64641,04
215,7171369,8844,1738666,6141,544,1738666,611369,88441,54
225,7161371,5654,1688677,9541,484,1688677,951371,56541,48
235,7161362,5234,1958620,7141,764,1958620,711362,52341,76
245,7151359,8274,2038606,1241,834,2038606,121359,82741,83
255,7171366,0074,1858641,9341,664,1858641,931366,00741,66
265,7161361,2614,1998613,8141,794,1998613,811361,26141,79
275,7161365,7154,1868641,2041,664,1868641,201365,71541,66
285,7171366,3234,1848643,6841,654,1848643,681366,32341,65
295,7171378,5354,1478721,3741,284,1478721,371378,53541,28
305,7021370,0934,1628691,0241,424,1628691,021370,09341,42
Mnimo5,7021258,9324,1007965,0240,8124,1007965,021258,9340,812
Mximo5,7191394,2004,5418820,8745,1984,5418820,871394,2045,198
Promedio5,7161356,5694,2168583,8341,9674,2168583,831356,5741,967
De igual manera se obtiene el consumo para las cargas parciales y las cuales que se adjunta en el presente informe en el APENDICE E (Clculos y resultados).Se muestra en el CUADRO 1310 y CUADRO 1310, un resumen del consumo de combustible, rendimiento, consumo especfico y eficiencia de la C.T. Independencia.
CUADRO 139: RENDIMIENTO Y OTROS INDICES RELACIONADOS AL CONSUMO DE COMBUSTIBLE (Wartsila 01)UnidadCarga nominal (MW)Potencia Efectiva Heat Rate o Consumo especfico de calorConsumo de CombustibleRendimientovolumtricoConsumo especfico de combustibleEficiencia
(kW)BTU/kWh(m3/h)(kWh/m3)(m3/kWh)(%)
Wartsila 015,75714,357924,01320,74,330,231143,1
43848,399224,81035,53,720,269138,3
32975,309251,2802,83,710,269836,9
21982,3110393,0600,93,300,303132,8
1,51486,5312191,4528,62,810,355628,0
CUADRO 1310: RENDIMIENTO Y OTROS INDICES RELACIONADOS AL CONSUMO DE COMBUSTIBLE (Wartsila 03)UnidadCarga nominal (MW)Potencia Efectiva Heat Rate o Consumo especfico de calorConsumo de CombustibleRendimientovolumtricoConsumo especfico de combustibleEficiencia
(kW)BTU/kWh(m3/h)(kWh/m3)(m3/kWh)(%)
Wartsila 035,75717,148192,61366,34,180,239041,6
43984,148479,6985,54,040,247440,2
32985,349101,7792,63,770,265537,5
21988,4910721,5621,93,200,312731,8
1,51489,0812531,3544,32,740,365627,2