Group 04 (library presentation)

Post on 18-Jul-2015

80 Views

Category:

Engineering

3 Downloads

Preview:

Click to see full reader

Transcript

Group-41. Habibur Rahaman – 10672. Shokot Karmokar - 10943. Mosaraf hossen– 1049

B I S H W A

S A H I T T O

K E N D R O

Project LocationGoogle mapSite surrounding

Project StudyConceptBubble diagramFloor planZoningParkingHorizontal & vertical circulationNatural lightingNatural & mechanical ventilationOutdoor activitiesIndoor – outdoor relationshipForm & elevation treatmentStructural systemsMaterials

Standard DataTime Saver StandardNeufert

Program

ReferenceBooksInternet

Content

Architect – Maruf Shaihan Sunny

1. Location – Poribug, Banglamotor

2. Project area – 130052 sft

3. Built area – 8162 sft

Site location

Site Surrounding

Entry

Lobby

Parking,Electromechanical &

Workshop

Reception Vertical Circulation

Corridor

Seminar , Library, Cafeteria, Office , Conference, VIP lounge, Roof top

garden.

Office room, Photo Exhibition, Storage, Book selling

Movie hall room,Class room, Office,

Archive, VIP lounge,Roof top canteen.

Wash

N

Concept

:

BSK ( Bishwa Sahitto Kendro) designed to respect existing site surrounding condition. BSK not only an single library, it’s a composite institute of many educational program. Architect give the modern shape of that building with arrange many functions in these. Architect played with form demands of city people. Landscape, indoor-outdoor relationship, library, space, natural light, recreational space designed smartly in this project.

Bubble Diagram

N

Function :1. Entrance (pedestrian, disable,

vehicular, service) -2. Parking – 3447 sft3. Plaza – 575 sft4. Reception & Information – 456 sft5. Vertical access (lift, stair) – 770 sft

Pic

ture

fro

m d

iffe

ren

t a

ng

le

Ground Floor

Pedestrian Entry

Road access

Parking ramp

Pic

ture

fro

m d

iffe

rent

angle

N

Ground Floor

Handicapped ramp & Lift lobby

Lift & Stair

Reception room

N

Existing Length 55’-6”

Existing Width 4’-0”

Existing Slope 1:8

Existing handicapped ramp

Time saver standard

Level Height 6’-6”

Ramp Length (min) 78’-0”

Ramp Width (min) 6’-0”

Ramp Slope 1:12

Height 6’-6”

Ground Floor Disable Entry

Existing Length 37’-0”

Existing Width 14’-6”

Existing Slope 1:8

Existing veh. ramp Time s. standard

Level Height 4’-6”

Length (min) 36’-0”

Width (min) 16’-0”

Ramp Slope 1:8

Height 4’-6”

N

Ground Floor Ramp & Parking

N

Treatment for natural light

Head room clear height 8’ - 6”

Ground Floor Ramp & Parking Require.

1st Floor 6230 sft

Ground Floor 1410 sft

Use Area Each Level

2nd Floor 6010 sft

3rd Floor 5890 sft

4th Floor 6092 sft

5th Floor 4265 sft

6th Floor 5335 sft

7th Floor 4990 sft

8th Floor 4355 sft

Total Area 44897 sft

Req. Parking = 44574/ 2000= 22.28 Nos

Basement 13 Nos

Ground Floor 09 Nos

Existing Parking

Total 22 Nos

Pic

ture

fro

m d

iffe

ren

t a

ng

le

N

1st FloorFunction :

1. Multipurpose hall room-1299 sft2. Book shop – 610 sft3. Movie hall room –796 sft4. Service (Lift, lobby, stair, wash) -

837 sft

Movie hall room

Book shop

Multipurpose hall room

N

1st Floor Acoustic Treatment & Space Require.

Common area per person in

building

Seating Arrangement

Acoustic Treatment

Type of

Building

Type of

Room

Area per Person

Apartment

(m2) (ft2)

Assemblybuilding

100 - 400

Lectureroom

Library

0.6

0.6

30 - 100

Cinema

Concert hall

0.6

Theatre 0.6

Time Saver Standard

Acoustic condition

Existing layout in book shop room

Movie hall room length – 10.10 m.Multipurpose hall room length – 17.22 m.

Lib

rary

im

ages

N

Function :1. Library – 1835 sft2. Music archive room – 396.0 sft3. Library room-208.0 sft4. Service (Lift, lobby, stair)5. Office- 418 sft

2nd Floor

Offic

e r

oo

mM

usic

arc

hiv

e

Experience formula for library size

& cost

Population No. of size Seats per 1,000 population

Under 10,000 1010,000-35,000 5100,000-200,000 3200,000-500,000 1½5000,000 and up 1

N

2nd Floor Library Basic Requirements

The Library for the Town 10,000

Population

Time Saver Standard

Size of book collection 20,000 volumes Space for book collection 2,000 sftSpace for reader (40 seats min.) 30 sft per person 1,200 sftStaff works space 1,000 sftEstimated additional space for utilities, circulation and miscellaneous 2,800 sftTotal estimated floor space 7,000 sft

Existing Library 10,000+

Size of book collection 25,000 volumes Space for book collection 2,085 sftSpace for reader (52 seats) 22.69 sft per person 1,180 sftStaff works space 1,107 sftEstimated additional space for utilities, circulation and miscellaneous 2,055 sftTotal estimated floor space 7,000 sft

Existing layout in library

Time Saver Standard

Common area per person in

building

Type of

Building

Type of

Room

Area per Person

Museum

(m2) (ft2)

Institution

30 - 100

Libraries 30 - 100

Kindergar. 2-3

N

2nd Floor Library Natural lightStandard lumen in different activity

Activity Illumination(lux, lumen/m2)

Public areas with dark surroundings 20 - 50

Simple orientation for short visits 50 - 100

Working areas where visual tasks are only occasionally performed

100 - 150

Warehouses, Homes, Theaters, Archives 150

Easy Office Work, Classes 250

Normal Office Work, PC Work, Study Library, Groceries, Show Rooms, Laboratories

500

Supermarkets, Mechanical Workshops, Office Landscapes

750

Normal Drawing Work, Detailed Mechanical Workshops, Operation Theatres

1,000

N

4th Floor

Common area per person in

building

Type of

Building

Type of

Room

Area per Person

Bars

(m2) (ft2)

Cafeteria

15 - 50

10 - 50

Dining hall

15 - 50Cocktail Lounge

10 - 50

Function :1. Cafeteria - 766.0 sft2. Open terrace - 907.0 sft3. Art gallery - 822.0 sft4. Class room - 796.0 sft5. Kitchen –219 sft

existing seatingIndoor – 48 Nos. ( Using 15.95 per person)Outdoor – 21 Nos. ( Using 43.19 per person)

Open terrace

Cafeteria indoor

Cafeteria outdoor

Functional Organization

Public Exhibition gallery , multi-purpose hall, library

book shop , cafeteria , toilet , common lobby.

Semi – public Admin , Class room (music,dance,drama,art,

debate , audio visual, language club & poetry)

Private Office space , conference room , archive ,

storage , book transition (loading & unloading)

2ndFLOOR PLAN

N

Program chart1.Libaray2.Libaraian room3.Office space4.Lobby5.Store area6.Toilet 7.Emr

3rd FLOOR PLAN

N

Program chart1.Libaray2.DRS(Developing Reading Habits) 3.Office space4.Lobby5.Toilet 6.Emr

4th FLOOR PLAN

N

5th FLOOR PLAN

N

6th FLOOR PLAN

N

7th FLOOR PLAN

N

8th FLOOR PLAN

N

ROOF FLOOR PLAN

N

BASEMENT FLOOR PLAN

N

ELEVATION

N

SOUTH ELEVATION EAST ELEVATION

ELEVATION

NORTH ELEVATION

WEST ELEVATION

SECTION

N

SECTION C-C

SECTION D-D

SECTION

SECTION C-C

SECTION B-B

SECTIONAL MODEL

INDOOR & OUT DOOR RELATIONSHIP

Structure system- Post lintel.

Column grid- MAX- 24’- 10”c/c

Column size- 2’-0” X 1’-3”

Peripheral beam- Use in basement &

Ground floor to 6th

floor.

Share wall- Use in outside, in

side brick wall.

Number of column- 26 nos.

STRUCTURAL ANALYSIS

ADVANTAGE & DISADVANTAGE

Demerits:

Lift is not shone from main entry.

Lift core is too small.

In the time of car parking, one car is stay

after another.

Lift is not use for market, it’s only use for

office.

Merits:

Market & Office entry is different.

Market circulation is well.

Escalator is easily definable.

Good lighting system.

Fire fighting stair is good proportioned.

top related