Sensortech Systems IncMoistTech.com

• Global Headquarters – Moorpark CA USA– Sales Team North and South America– USA East Coast – Mass USA

• Asia Pacific Headquarters – Sydney Australia– Asia Pacific Distribution Network

• China Office – Shanghai China– China Distribution Network

• Hong Kong – China Tobacco• India Offices – Chennai, Hyderabad

– Indian Distribution Network• Middle East – Dubai

– Middle East Distribution Network • Africa – Johannesburg, Durban, Cape Town

– African Distribution Network• European Headquarters – Eindhoven Holland

– Europe and Eastern European Distribution Network

Worldwide Network

NIR Theory

The basics of our technology

Discovery of Infrared in 1800

• Sir Frederick William Herschell (1738-1822)

• Herschel directed sunlight through a glass prism to create a spectrum - the "rainbow" created when light is divided into its colours - and measured the temperature of each colour using a thermometer

NIR in the Spectrum

400-700

Electronic

700-1100

VibrationOvertones

1100-2500

VibrationOvertones

2500-10000

FundamentalVibrations

10-400

Electronic

UV Visible VNIR NIR Mid-IR

Visible 400-780nm VNIR

780-1100nmNIR

1100-2500nm

Interactions of NIR Light

A

A

A

A

ABSORBED LIGHT

TRANSMITTED LIGHT

BACKSCATTERED LIGHT

PRODUCT

WHEN LIGHT HITS A PRODUCT IT WILL INTERACT IN VARIOUS WAYS. TRANSMITTED LIGHT WILL PASS THROUGH THE PRODUCT

BACKSCATTERED LIGHT WILL REFLECT FROM THE PRODUCT

LIGHT WILL ALSO BE ABSORBED BY THE PRODUCT

ABSORBTION IS THE KEY TO OUR NIR ANALYSIS

Typical NIR Absorbance Ranges

Functional Group Absorbance Range• O-H

–Water 1940, 1430 –Alcohols 2100, 1600

• C-H –Aliphatic 2200-2500, 1670-1780 –Aromatic 2100-2200, 1670-1780

• N-H –Amines 1980-2050, 1500

NIR Absorbtion Curve H2O

0.00

0.10

0.20

0.30

0.40

0.50

0.60

0.70

0.80

1100 1300 1500 1700 1900 2100 2300 2500Wavelength (nm)

Abs

orba

nce

Water

NIR Absorption Curve - Moisture

NIR Absorbtion Curve H2O

0.00

0.10

0.20

0.30

0.40

0.50

0.60

0.70

0.80

1100 1300 1500 1700 1900 2100 2300 2500Wavelength (nm)

Ab

sorb

an

ce

Water

MEASURE

MEASURE

REFERENCE

REFERENCE

NIR Different Tobacco Types

0.10

0.20

0.30

0.40

0.50

0.60

0.70

0.80

0.90

1100 1300 1500 1700 1900 2100 2300 2500

Wavelength (nm)

Abs

orba

nce

Light ReconstitutedBurleyExpandedVirginiaDark ReconstitutedTurkish

MEASURE

MEASURE

REFERENCE

REFERENCE

Basic Fixed Filter NIR Sensor

Sample

Lamp

Filter Wheel

DETECTOR

Measure Filter

Reference Filter

Basic NIR Measurement

Measurement µReferenceMeasure

Ratio-Based Measurement– Eliminates sensitivity to distance– Improves stability– Improves accuracy– Problem drift over time

MoistTech NIR Sensor

Sample

Lamp

Filter Wheel

DETECTOR

Measure Filter

Reference Filter

PRIME BEAM

MoistTech Measurement

Measurement µReferenceMeasure

Measure’Reference’´

Prime beams give improved instrument stability eliminating drift

Moisttech Ratio-Based Measurement with prime beamEliminates sensitivity to distanceImproves stabilityImproves accuracy

NO drift over time

PRIME BEAM

Advanced MoistTech NIR Sensor

Sample

10W Parabolic Lamp

Multi Filter Wheel

DETECTOR

Measure Filter 1

Reference Filter 1

Measure Filter 2

Reference Filter 2

Polished Aluminium Reflectors

Products and Accessories

• IR3000 – General NIR Applications• 828 – Tobacco NIR Applications• CCS3000 – Mining and Minerals Applications• 838 – Laboratory NIR Applications• 858 – Laboratory / At Line Applications• 868 – Biomass Gauge / Laboratory Non

Homogenious NIR Applications

NIR Product Overview

IR3000 Standard NIR

IR3000 Standard NIR

• Use for all general applications• Multi Constituent Versions Available• Moisture Range 0-95% (ppm versions available)• Accuracy 0.01 – 0.3% product dependant (Typical

0.1%)• Power 90-260VAC 50/60Hz (24VDC available)• Analogue Outputs 3 x 4-20mA • Digital Outputs RS232,485,Ethernet, Modbus,

Profibus, Profinet, Devicenet

IR3000 Standard NIRTypical Applications

• Wood Products• Food Products• Powders• Paper• Pharmacuticals

828 Tobacco NIR

828 Tobacco NIR

• Use for all tobacco applications• Typical Moisture Ranges 5-25%, 20-40%, 0-70% • Accuracy 0.1% Cut Tobacco, CRS, Lamina, 0.3%

Stem• Power 90-260VAC 50/60Hz (24VDC available)• Analogue Outputs 3 x 4-20mA • Digital Outputs RS232,485,Ethernet, Modbus,

Profibus, Profinet, Devicenet

828 Tobacco NIRTypical Applications

• Cut Tobacco• CRS (Cut Rolled Stem)• Lamina Strips• Leaf• Expanded Tobacco

CCS 3000 Mining & Minerals

CCS Mining and Minerals

• Use for Mining and Minerals applications• Special optical design optimised for dark

products• Typical Moisture Ranges 0-25%, 25-40%, 0-70% • Accuracy 0.1% - 0.5% product dependant• Power 90-260VAC 50/60Hz • Analogue Outputs 3 x 4-20mA • Digital Outputs RS232,485,Ethernet, Modbus,

Profibus, Profinet, Devicenet

CCS Mining and MineralsTypical Applications

• Sinter Mix• Coke• Coal• Iron Ore• Zinc Ore• Copper Ore• Nickel Ore

838 Laboratory NIR

838 Laboratory NIR

• Use for applications where turntable is required, where product could be non - homogeneous

• Moisture Range 0-95% (ppm versions available)• Accuracy 0.01 – 0.1% product dependant• Power 90-260VAC 50/60Hz • Analogue Outputs 3 x 4-20mA • Digital Outputs, Ethernet, USB

858 Laboratory NIR

858 Laboratory NIR

• Use for applications where product is homogeneous (Powders, Granules or product can be crushed)

• Encapsulated sample chamber • Moisture Range 0-95% (ppm versions available)• Accuracy 0.01 – 0.1% product dependant• Power 90-260VAC 50/60Hz • Analogue Outputs 3 x 4-20mA • Digital Outputs Ethernet, USB

868 Laboratory NIR

868 Laboratory NIR

• Use for applications where large turntable is required, where product is very non – homogeneous

• PLC averages data over several rotations to get repeatable results

• Moisture Range 0-95% (ppm versions available)• Accuracy 0.01 – 0.5% product dependant• Power 90-260VAC 50/60Hz • Analogue Outputs 3 x 4-20mA • Digital Outputs RS232,485,Ethernet

ACCESSORIES

Operator Interface HMI

M_Connect OWS Operator Workstation

Remote Displays

Cooling Panel and Accessories

Non Contact Product Temperature Sensor

Transmission Adapter

Powder Sampler

Powder Sampler Cut Out

Sample Probe

Viewing Window

Calibration Check Standards

Scanning Frames and PC

NETWORKING & COMMUNICATION

Standard and Optional

Pocket PC or other wireless devicePlant computer / Lap top

Wall/Post Colour TouchPanel Operator Interface

“Blue Eye Wireless Link”Or Bluetooth

OR

IR3000

Power Input 90-260VAC-Optional 24VDC

Moisttech Gauge Connectivity

Ethernet:-Operator Interface-Laptop-Desktop Computer-3 Ethernet devices Simultaneously

SCADA/ PLC/REMOTE DISPLAY/M_CONNECT

Ethernet, Profibus, Profinet, Modbus, RS232, RS485 or 3 x 4-20mA

Modbus - Standard• Communication using serial and Ethernet protocol

available• Modicon Proprietary protocol • MoistTech developed software driver in-house,

embedded in rabbit PC firmware• Modbus generally for customers wishing to connect to

Modicon PLC only• List of available parameters provided in word document• Modbus “C” file available• Modbus RTU for persons wishing to write their own sw• Same Command list Version 2 and version 3

Profibus - Optional

• Siemens Communication protocol using serial interface• Siemens Proprietary protocol • HMS chip located on main PCB converts RS232 to

Profibus• Profibus generally for customers that wish to connect to

Siemens PLC only• List of available parameters provided in word document• GSD file available “Drag and Drop”• Same GSD Version 2 and Version 3

Profinet - Optional

• Siemens Communication protocol using Profibus over Ethernet bus

• Siemens Proprietary protocol • MoistTech developed software driver in-house,

embedded in rabbit PC firmware• Profinet (Profibus over Ethernet) comms for customers

that wish to connect to Siemens PLC only• List of available parameters provided in word document• GSDML file available “Drag and Drop”• Certified and tested by Siemens• Same Protocol for Version 2 and Version 3

Devicenet - Optional

• Communication using serial protocol• Allen Bradley Proprietary protocol • HMS chip mounted on the main PCB converts

serial to Devicenet• Devicenet generally for customers wishing to

connect to Allen Bradley PLC only• List of available parameters provided in word

document• EDS file available “Drag and Drop”• Same Comms Protocol for version 2 and version 3

RS232, RS485 and RS422 – Optional at No Cost

• Communication using serial port• Moisttech proprietary protocol for our

software • Modbus RTU for customers wishing to

interface our gauge with their own software• Must be requested at time of order• Same comms for Version 2 and version 3

Steel Plant Sinter Mix

Steel Slag in Coke Plant

Coal – Coal Mine

Biscuits – Snack Food Plant

Potato Chips

Detergent Powder