GESTRA Steam Boiler Equipment SPECTORmodule – for operation according to EN 12953
Condensate Monitoring
Type Approvals: EC approvalTÜV (Germany)
Low-level limiter of “high-integrity design”: level electrode NRG 16-50, level switch NRS 1-50, SIL 3
Separate high-level alarm of “high-integrity design”: level electrode NRG 16-51, level switch NRS 1-51, SIL 3
Level control with high-level alarm and remote water level indicator: level probe NRG 26-21, level controller NRR 2-52 and control valve V726
Water level gauge
Conductivity measurement with indicator, conductivity limit switch and continuous blowdown control: conductivity electrode LRGT 16-2, continuous blowdown controller LRR 1-52, continuous blowdown valve BAE
Sample cooler
Blowdown flash vessel
Residual blowdown cooler
Automatic intermittent blowdown: intermittent blowdown valve MPA, pilot valve
Blowdown receiver
Pressure limiter DSF
Pressure transmitter DRT
Pressure gauge
Safety valve GSV
Safety temperature monitor (limiter): resistance thermometer TRG, temperature switch TRS 5-50, SIL 3
Thermometer
Strainer
Vent valve
Stop valve (also in bypass)
Non-return valve
Electrical/pneumatic control valve V 725
Feedwater pump
Monitoring of the feedwater / condensate
Burner control unit
Burner
Superheater
Economizer
GESTRA Steam Boiler Equipment
Example of a Steam Boiler Plant Operating without Continuous Supervision (72h)
GESTRA AG
Steam trap with trap test set: test chamber VKE, electrode NRG 16-19 and test station NRA 1-3 for max. 16 traps
Non-return valve RK 86
Quality control for ingress of foreign matter, using type-approved systems as per VdTÜV bulletin on water monito-ring facilities (WÜ 100)
Monitoring for ingress of acids, blowdown, raw water etc.: conductivity electrode with integrated resistance thermo-meter LRG 16-9, conductivity switch LRS 1-7
Monitoring for ingress of oil, grease etc.: oil and turbidity detector OR
Electrical/pneumatic three-way valve for discharging the contaminated condensate
Condensate tank
Shutdown of the condensate-return system or interruption of the safety chain
8191
63-0
0/12
11 ·
© 2
011
· GES
TRA
AG ·
Brem
en ·
Prin
ted
in G
erm
any
Münchener Str 77, D-28215 BremenP.O. Box 10 54 60, D-28054 Bremen
Telephone +49 (0) 421-35 03-0Telefax +49 (0) 421-35 03-393
E-Mail gestra.ag@flowserve.comInternet www.gestra.de
Condensate monitoring
1 7
8
9
10
11
12
13
14
15
16
A
B
C
D
E
F
G
17
18
19
20
21
22
23
24
25
26
2
3
6
4
5
1
1
1
7 8
9
9
10
11 12 1313
13
14
14
1516
17
18
19
19 1919
19
19
19
19
19
20
20
21
22
23
2425
26 27
2
2
3
3
4
6
5
5
5
A
BB
C
DD
EF
G
27
GESTRA Steam Boiler EquipmentSPECTORmodule – for operation according to EN 12953
Münchener Straße 7728215 Bremen
Telefon +49 (0) 421-35 03-0Telefax +49 (0) 421-35 03-393
E-Mail martina.stark@de.gestra.comInternet www.gestra.de
Condensate Monitoring
top related